N484LF
Registered owner: GEISINGER MEDICAL CENTER, PA (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| GEISINGER MEDICAL CENTER (3GMA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
J · 2013-04-18 Matched by certificate designator
ATA 6320
Source: SDR 3GMA20130419003 · FAA SDRSA/C WAS IN CRUISE FLIGHT WHEN THE XMSN CHIP ILLUMINATED ON THE CAD. PILOT WAS 20 MINUTES INTO A 30 MINUTE FLIGHT. FLEW FOR 1-2 MINUTES UNTIL A SUITABLE LANDING AREA WAS FOUND. LANDED AND SHUT DOWN IMMEDIATELY. NO ABNORMAL SOUND WAS NOTED, TRANSMISSION TEMP AND OIL PRESSURE NORMAL.
O · 2013-02-05 Matched by certificate designator
ATA 5340
Source: SDR 2013FA0000075 · FAA SDRSON PREFLIGHT INSPECTION, FOUND CRACKED MOUNTING BRACKET ON CROSS-TUBE MOUNTED LANDING LIGHT.