N484LF

EUROCOPTER DEUTSCHLAND GMBH MBB-BK 117 C-2 · 2009 · Valid Registration

Registered owner: GEISINGER MEDICAL CENTER, PA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
GEISINGER MEDICAL CENTER (3GMA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

J · 2013-04-18 Matched by certificate designator
ATA 6320

A/C WAS IN CRUISE FLIGHT WHEN THE XMSN CHIP ILLUMINATED ON THE CAD. PILOT WAS 20 MINUTES INTO A 30 MINUTE FLIGHT. FLEW FOR 1-2 MINUTES UNTIL A SUITABLE LANDING AREA WAS FOUND. LANDED AND SHUT DOWN IMMEDIATELY. NO ABNORMAL SOUND WAS NOTED, TRANSMISSION TEMP AND OIL PRESSURE NORMAL.

Source: SDR 3GMA20130419003 · FAA SDRS
O · 2013-02-05 Matched by certificate designator
ATA 5340

ON PREFLIGHT INSPECTION, FOUND CRACKED MOUNTING BRACKET ON CROSS-TUBE MOUNTED LANDING LIGHT.

Source: SDR 2013FA0000075 · FAA SDRS