N484TP

RAYTHEON AIRCRAFT COMPANY 400A · 1998 · Fixed-wing multi-engine · 2 engines · 10 seats · Valid Registration

Registered owner: SKY AVIATION HOLDINGS LLC, FL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Jet Linx Aviation, LLC (9JLA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

1 report on file, 2021-06-22.

OTHER · 2021-06-22 Matched by certificate designator
ATA 2750

Part: CABLE — BROKEN (RT FLAP) · airframe 10,606 hrs · 8,307 cycles

DURING A SCHEDULED MAINTENANCE INSPECTION, IT WAS NOTICED THAT THE RIGHT FLAP OUTBOARD CABLE DID NOT HAVE TENSION AND THE FLAP FORWARD CABLE WAS TOUCHING THE RIGHT-WING REAR SPAR. FURTHER INVESTIGATION REVEALED THAT THE CABLE WAS BROKEN FROM THE SWAGED FITTING DUE TO CORROSION. WHILE THIS HAPPENED ONLY IN THE RIGHT WING, BOTH (LEFT AND RIGHT) CABLES WILL BE REPLACED AT THIS VISIT. POSSIBLE REASON: THE FRONT CABLES RUN BELOW THE SPOILERS SURFACES AND THEREFORE ARE SUBJECT TO RAINWATER. THE CURRENT 400/400A MAINTENANCE MANUAL CALLS FOR LUBRICATING THE LEVER ASSEMBLIES, RAILS AND ROLLERS BUT NOT THE FLAP CABLES SWAGED FITTING. SUGGESTIONS (FOR ADDING TO THE MAINTENANCE MANUALS): INSPECT FOR CONDITION AND APPLY WATER RESISTANT SEALANT TO BELLCRANK DRIVER CAVITY TO PREVENT WATER ACCUMULATION AND INSPECT CONDITION EVERY B CHECK. OR FILL BELLCRANK DRIVER CAVITY WITH GREASE AND INSPECT CONDITION EVERY B CHECK. OR ADD AN INSPECTION/REPLACEMENT SCHEDULE TO THE INSPECTION PROGRAM.

Source: SDR IZ2R2021062320210