N498AB

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Executive Jet Management, Inc. (CWQA)Operatoron 2010-12-13Operator named in NTSB report

Accident & incident history

Incident · 2010-12-13 Operator named in NTSB report
CESSNA 560XL No injuries Part 135Executive Jet Management, Inc.

Operated by EXECUTIVE JET MANAGEMENT INC (per NTSB report)

Source: NTSB case CEN11IA111

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

2 reports on file, 2014-09-23 – 2014-09-24.

SMOKE/FUMES/ODORS/SPARKS · 2014-09-24 Unresolved
ATA 2150

Part: ACM — FAILED · airframe 6,986 hrs · 5,030 cycles

AIRCRAFT WAS POSITIONED ON THE RAMP WITH GROUND POWER CART ON, ACFT POWER ON AND THE FREON AIR-CONDITIONING SYSTEM IN OPERATION. THE CREW NOTICED SMOKE COMING FROM THE TAIL AREA OF THE ACFT AND ALERTED LINE PERSONNEL. THE LINE PERSONNEL OPENED THE AFT BAGGAGE DOOR, OPENED THE ACCESS DOOR TO THE FREON AIR CONDITIONER COMPRESSOR/MOTOR ASSY. THEY WERE ABLE TO EXTINGUISH A SMALL FIRE WITH A HAND HELD FIRE EXTINGUISHER AND REMOVED POWER FROM THE ACFT. REMOVED FREON AIR CONDITIONER COMPRESSOR/MOTOR ASSY FROM ACFT. FOUND THE MOTOR HAD OVERHEATED AND CAUSED SMOKE AND FIRE DAMAGE TO THE AIR CONDITIONER COMPRESSOR/MOTOR ASSY AND THE A/C SYSTEM CURRENT LIMITER WAS BLOWN. INSPECTED AFT BAGGAGE/TAIL CONE AREA, NO DAMAGE FOUND. R & R THE AIR CONDITIONER COMPRESSOR/MOTOR ASSY AND A/C SYSTEM CURRENT LIMITER.

Source: SDR CWQR20140924006
OTHER · 2014-09-23 Matched by certificate designator
ATA 2133

Part: OUTFLOW VALVE — MALFUNCTIONED (CABIN PRESSURE) · airframe 6,985 hrs · 5,029 cycles

DURING CRUISE CREW EXPERIENCED CABIN PRESSURIZATION FLUCTUATIONS & THEN LOSS OF CABIN PRESS CONTROL. CHECK LIST FOLLOWED, EMER DECLARED, OXYGEN MASKS DEPLOYED, EMER DECENT & UNSCHEDULED LANDING PERFORMED WITHOUT INCIDENT. PRIMARY OUTFLOW VLV REPLACED PN 9912409-10 SN 440. OPERATIONS CHECKED GOOD.

Source: SDR CWQA20140923001