N503JB
Registered owner: JETBLUE AIRWAYS CORP, NY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
78 reports on file, 2000-09-27 – 2022-12-26.
Part: TAB — DAMAGED (R1 DOOR) · airframe 85,080 hrs · 31,760 cycles
FLT#521, BOS-PBI. R1 DOOR WILL NOT ARM. REPLACED R1 DOOR BROKEN YOYO TAB ON UPPER DOOR LINING IAW AMM 25-23-46-000-001A. OPS CHECK OK.
Part: BULB — INOPERATIVE (EMERGENCY LIGHTS) · airframe 84,930 hrs · 31,702 cycles
FLT#393, BOS-DEN. 'AFT OVERHEAD EXIT SIGN HAS SEVERAL BURNT-OUT BULBS; REMOVED AND REPLACED AIRPLANE LEFT OVERWING EMERGENCY EXIT SIGN IAW AMM 35-51-16.NO FURTHER DEFECTS NOTED.A/C OK FOR CONTINUED SERVICE.'
Part: UNKNOWN — ODOR (CABIN) · airframe 84,713 hrs · 31,627 cycles
FLT #771, DIRTY SOCK SMELL ON DESCENT 9000' UNTIL AT THE GATE. C/W INFO NOTICE 2017 - T015 SEC B1 DECONTAMINATION LEVEL A ACCOMPLISHED IAW AMM 21-00-00-615-802. ACFT IS OK FOR SERVICE. OPEN
Part: NONE — NONE · airframe 84,414 hrs · 31,515 cycles
FLT#641, BOS-CLE. 'CABIN ODOR ON DESCENT THEN DISSIPATED AFTER 10 MINS. THE SMELL STARTED PASSING 10,000, CABIN ODOR FORM WAS COMPLETED. (SUPPLEMENTAL INFORMATION TO FOLLOW).
Part: SELECTOR VALVE — FAILED (2524GM) · airframe 82,889 hrs · 30,935 cycles
FLT#25, BOS-BGI. (AIRCRAFT PERFORMED AN AIR TURN BACK INTO BOS). ' UPON RETRACTION OF L/G ON TAKEOFF L/G LGCIU 1 FAULT ( PAX CONV ITEM(S) - LTV - INDIVIDUAL ); REF LOG PAGE 3313446 ITEM 2 (REPLACED LANDING GEAR SELECTOR VALVE REF AMM CHPT 32-31-34, SEE DEFECT 3313447 ITEM 1FOR OPS AND LEAK CHECK.) AND LOG PAGE 3313447 ITEM 1 (PREFORMED OPS CHECK OF SELECTOR VALVE AND LEAK CHECK REF AMM 32-31-00 OPS CHECK GOOD).'
Part: SKIN — CORRODED (LT WING) · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, (EA A22-261-01) WINGS/LH WING/ TOP SKIN PANEL #2/ TE OVERHANG LOWER SURFACE AT LEVEL OF RIBS 15-1/ CORROSION- PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)
Part: NONE — NONE · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, (EA A22-218-01) FUSELAGE / REAR FUSELAGE/ UPPER SKIN PANEL/ FR 69/70 AT LEVEL OF STR 4L/ DENT- PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)
Part: EPSU — FAILED (12WL) · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, FAULT EPSU-EMERGENCY POWER SUPPLY UNIT 12WL NOT PASS TEST IN PASSENGER CABIN (1 EA) ; REF AEROMAN N/R 2022-132476, REMOVED AND REPLACED EPSU-EMERGENCY POWER SUPPLY UNIT 12WL IN PASSENGER CABIN (1 EA) IAW 33-51-38-000-001-A AND AMM 33-51-38-400-001-A PERFORMED OPERATIONAL TEST EPSU BITE CHECK IAW AMM 33-51-00-710-001 TEST IS OK
Part: NONE — NONE · corrosion level 2 · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, CORROSION TRAILING EDGE OVERHANG LOC. AT LEVEL RIB 15 ON LH WING (CPCP RELATED 572179-01); EVALUATED REWORK AREA TRAILING EDGE OVERHANG LOC. AT LEVEL RIB 15 +7 INCH ON LH WING EN FOUND OUT OF LIMITS IAW SRM 57-21-11-283-007 TABLE 002 LOSS MATERIAL IS 19.80 %. MEASURED AFTER REWORK ARE L: 5.756 INCH, W: 1.544 INCH, REPAIR ACCOMPLISHED AS PER EA 57-0090-22 AND JETBLUE EC A22-260-01. ALL WORK WAS ACCOMPLISHED ON AE NR 2022-132342 EVALUATED REWORK AREA TRAILING EDGE OVERHANG LOC. AT LEVEL RIB 15 +7 INCH ON LH WING EN FOUND OUT OF LIMITS IAW SRM 57-21-11-283-007 TABLE 002 LOSS MATERIAL IS 19.80 %. MEASURED AFTER REWORK ARE L: 5.756 INCH, W: 1.544 INCH, REPAIR ACCOMPLISHED AS PER EA 57-0090-22 AND JETBLUE EC A22-260-01. ALL WORK ACCOMPLISHED ON AE NR 2022-132342
Part: NONE — NONE · corrosion level 2 · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, CORROSION TRAILING EDGE OVERHANG LOC. AT LEVEL RIB 15 ON LH WING (CPCP RELATED 572179-01); "EVALUATED REWORK AREA TRAILING EDGE OVERHANG LOC. AT LEVEL RIB 15 +7 INCH ON LH WING AND FOUND OUT OF LIMITS IAW SRM 57-21-11-283-007 TABLE 002 LOSS MATERIAL IS 19.80 %. MEASURED AFTER REWORK ARE L : 5.756 INCH, W: 1.544 INCH, REPAIR ACCOMPLISHED AS PER EA 57-0090-22 AND JETBLUE EC A22-260-01. ALL WORK ACCOMPLISHED ON AE NR 2022-132435 EVALUATED REWORK AREA TRAILING EDGE OVERHANG LOC. AT LEVEL RIB 15 +7 INCH ON LH WING AND FOUND OUT OF LIMITS IAW SRM 57-21-11-283-007 TABLE 002 LOSS MATERIAL IS 19.80 %. MEASURED AFTER REWORK ARE L: 5.756 INCH, W: 1.544 INCH, REPAIR ACCOMPLISHED AS PER EA 57-0090-22 AND JETBLUE EC A22-260-01"
Part: NONE — NONE · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, DENT EXTERNAL SKIN LOC BTW FR69 TO FR70 AND BTW STR 3L TO STR 4 UPPER FUSELAGE; MAJOR REPAIR REF ARM W/O 2022-132386 N/R 2022-132386 REPAIRED IAW EC# A22-218-01, EA 53-0083-22 (COVER R1, PARTS 1 AND 2) AND RDAF 81037097/0032022#A (CONSIDERED A MAJOR REPAIR)
Part: SKIN — CORRODED (LT WING) · airframe 82,884 hrs · 30,933 cycles
DURING HEAVY MAINTENANCE, CORROSION TRAILING EDGE UPPER SKIN LOWER AREA AT LEVEL RIB 7A ON LH WING; REF: ARM W/O 2022-67/1 N/R 2022-132414 FOUND WITHIN LIMITS IAW A320-SRM 57-21-11-283-007, TABLE 001. THIS REPAIR IS CATEGORY A, MAJOR REPAIR
Part: OIL SYSTEM — OVERSERVICED (ENGINES) · airframe 82,676 hrs · 30,864 cycles
FLT # 2121, BOS-PBI. DIRTY SOCK SMELL IN COCKPIT SHORTLY AFTER TAKEOFF FOR APPROX 5 MIN. DISSIPATED BY THE TIME WE REACHED 10000'. ODOR RETURNED IN DECENT, STRONGER, AND MORE PERSISTENT. LASTED MORE THAN 10 MIN. REDUCED IN INTENSITY WITH PACK 1 TURNED OFF; FOUND 1 AND 2 ENG OIL LEVEL OVER SERVICED AS PER AMM 12-13-79. ACCOMPLISHED INFO NOTICE 2017-T015I. NO ODOR DETECTED FROM BLEED SOURCES PACK NORMAL AS PER TSM 05-50-00-810-831-A.
Earlier reports · 2000–2021 · 65 reports
2021
Part: SLIDE — NO TEST (RT OVERWING) · airframe 80,645 hrs · 30,199 cycles
FLT 2080, FLL-DCA. EPSU R/H OVERWING LOCATION 12WL FOUND EXTERIOR RED LIGHT FAULT ON TEST; R & R R/H OVERWING SLIDE PER AMM 25-62-42, OPS CHECK GOOD (EMER LTS). OK FOR SVC.
2020
Part: BATTERY — NO TEST (EMERGENCY LIGHT) · airframe 79,765 hrs · 29,880 cycles
FLT 6435, VQQ - MCO. EMERGENCY, BAT AT 12 WL FAILED BAT CAP TEST. R & R EMERGENCY BAT AT 12WL, IAW AMM 33-51-38-400.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 79,765 hrs · 29,880 cycles
FLT 6435, VQQ - MCO. EMERGENCY BAT AT 11WL FAILED BAT CAP TEST. R & R EMERGENCY BAT AT 11WL, IAW AMM 33-51-38-400.
Part: LIGHT — INOPERATIVE (ROW 11) · airframe 79,764 hrs · 29,879 cycles
DURING HEAVY MAINTENANCE, ROW 11 RT ESCAPE LIGHT INOPERABLE, REF FLIGHTSTAR WO N503JB-01-01 N/R 00026. R & R ROW 11 RT ESCAPE SLIDE PATH LIGHT ASSEMBLY, IAW A320 AMM 33-51-19-000-003-A. EMERGENCY LIGHT OPERATIONS CHECK CARRIED OUT, IAW A320 AMM 33-51-00-710-001. OPERATIONS CHECK GOOD.
Part: FASTENER — SHEARED (FRAME 36) · airframe 79,764 hrs · 29,879 cycles
DURING HEAVY MAINTENANCE, ACCOMPLISH REPAIR OF SHEARED FASTENERS AND CRACKS FOUND AT CENTER FUSELAGE AT FR 36 LT & RT PRESSURE PANEL AFFECTING LT & RT FITTING CONNECTION. REPAIRED IAW FLIGHTSTAR EA 20046& RDAS 80854592/003/2020 ISSUE A. REFER TO JETBLUE EC A20-838-01. CLASSIFIED AS MAJOR.
Part: NOT REPORTED — CRACKED (NOT REPORTED) · airframe 79,764 hrs · 29,879 cycles
DURING HEAVY MAINTENANCE, CRACKS FOUND DURING INSPECTION SB A320-53-1254. REPAIRED PER SB A320-53-1263 & FLIGHTSTAR EA 20046 & RDAS 80854592/003/2020.
Part: CROSSBEAM — CRACKED (FRAME 16) · airframe 79,764 hrs · 29,879 cycles
DURING HEAVY MAINTENANCE, FR 16 RT AND CROSSBEAM HOLE 2 CRACKED. REPAIRED FR 16RT AND CROSSBEAM HOLE 2, IAW JETBLUE EC 2018-14-09-FAA-01 & REPAIR DRAWING R531-12926 D RDAS 80857172/003/2020.
Part: CIDS — NO TEST (L2 DOOR SLIDE) · airframe 79,764 hrs · 29,879 cycles
DURING HEAVY MAINTENANCE, CIDS TEST FAIL ESPU EXT LOAD AFT LT MESSAGE. R & R L-2 DOOR SLIDE, IAW A320AMM 25-62-44-000-012-A AND 25-62-44-400-007-A. PERFORMED SATISFACTORY OPERATIONS CHECK ON L-2 DOOR SLIDE, IAW A320 AMM 33-51-00-710-001-A REF FLIGHTSTAR NR 00157. SUPPLEMENTAL INFORMATION TO FOLLOW.
Part: BULB — INOPERATIVE (EMERGENCY LIGHTS) · airframe 79,764 hrs · 29,879 cycles
DURING HEAVY MAINTENANCE, OVERHEAD EMEGENCY EXIT SIGN CENTER AISLE AT ROW 18 INOPERABLE, REF FLIGHTSTAR WO N503JB-01-01 N/R 00027. R & R LIGHT BULBS ON OVERHEAD EMERGENCY EXIT SIGN CENTER AISLE ROW 18 WITH SATISFACTORY OPERATIONS CHECK, IAW A320 AMM 33-51-11.
Part: CYLINDER — LOW PRESSURE (L1 DOOR ASSIST)
L1 DOOR EMERGENCY CYL/ ACCUMULATOR BELOW LIMITS; SEVICED L1 DOOR AS PER AMM 52-10-00OK FOR SERVICE + REPLACED DIAPHRAM SEAL DISK IAW AMM 52-11-14. SUPPLEMENTAL INFORMATION TO FOLLOW.
2019
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 77,418 hrs · 28,995 cycles
FT # 225, FWD LEFT AND AFT LEFT EMERG LIGHT BATTERIES FAILED TEST; REMOVED AND REPLACED EMERG LIGHT BATTERIES FWD LEFT 10WL AND AFT LEFT 13WL IAW AMM 33-51-38
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 77,418 hrs · 28,995 cycles
FT # 225, FWD LEFT AND AFT LEFT EMERG LIGHT BATTERIES FAILED TEST; REMOVED AND REPLACED EMERG LIGHT BATTERIES FWD LEFT 10WL AND AFT LEFT 13WL IAW AMM 33-51-38
2018
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FWD CABIN AT FR 16. FLOORBEAM Y765 CORRODED REF NR 40126. REMOVED AND REPLACED FLOORBEAM Y765 IAW SRM 51-72-11.
Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BULK CARGO DOOR SILL FR61 +9 REF NR 40198. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER IAW SRM REF 53-41-48-300-063 FIG 001.
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FWD CABIN AT FR 16, DUMMY FLOORBEAM Y 254. REMOVED AND REPLACED FLOORBEAM Y254 IAW SRM 51-72-11 STEP C & 51-42-11.
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FWD CABIN AT FR 16 DUMMY FLOORBEAM Y503.2. REMOVED AND REPLACED FLOORBEAM 503.2 IAW SRM 51-72-11.
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FWD CABIN AT FR 16 Y1292. REMOVED AND REPLACED FLOORBEAM Y1292 AT FR 16 IAW SRM 51-42-11.
Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BULK CARGO DOOR SILL AT FR 61 +1 REF NR 40196. REMOVED CORROSION AND INSTALLED DOUBLER AS PER SRM REF 53-41-49-300-03 FIG 1 SHEET 001 A.
Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BULK CARGO DOOR SILL FR60+11 REF NR 40195. CORROSION REMOVED AND INSTALLED REPAIR AS PER SRM REF 53-41-40.
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 73,670 hrs · 27,564 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FWD CABIN AT FR 16 DUMMY FLOORBEAM Y 940. REMOVED AND REPLACED DUMMY FLOORBEAM Y940 IAW SRM 51-42-11 PAR F.
Part: OIL SYSTEM — LEAKING (APU) · airframe 72,919 hrs · 27,274 cycles
FLT 950, GND-JFK. DIRTY SOCK SMELL FROM PACK NOTICE IN DECENT SEE CABIN ODOR REPORT. (APU BLEED AIR SUPPLY SYSTEM) TROUBLESHOT PER INFO NOTICE 2017-T015C SECTION "B". FOUND OIL ON THE MATTING SURFACE OF APU INTAKE WHERE INTAKE DUCT SEATS. ENG RUN & CHK PERFORMED TO ISOLATE ENG. NO DEFECTS FOUND ON ENG. CONCLUDED APU TO BE THE CAUSE OF SMELL. APU BLEED AIR SUPPLY PUT ON MEL 36-12-01 CATEGORY "C". REQUIRES FURTHER TROUBLESHOOTING OF APU, FOR LEAKS. REQUIRED MORE GROUND TIME. SUPPLEMENTAL INFORMATION TO FOLLOW.
Part: EPSU — FAILED (EMERGENCY LIGHT) · airframe 71,344 hrs · 26,663 cycles
EMERGENCY LIGHT FAILED TO TEST. R & R THE EPSU 13WL. OPS CHECKED GOOD IAW AMM 33-51-38.
Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 71,277 hrs · 26,639 cycles
FWD EPSU 10WL BATTERY FAILED AN EMERGENCY LIGHTS SYS TEST. REPLACED THE EPSU BATTERY IAW AMM 33-51-38, OPS CHECKED GOOD.
Part: SLIDE — NO TEST (RT) · airframe 71,277 hrs · 26,639 cycles
FWD RT EMERGENCY SLIDE RAFT FAILED AN EMERGENCY LIGHT TEST. REPLACED THE SLIDE RAFT IAW AMM 25-62-44. FUNCTIONAL CHECKED GOOD, EMERGENCY LIGHTS TEST GOOD.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 71,277 hrs · 26,639 cycles
EMERGENCY LIGHT EPSU 11WL BATTERY FAILED AN EMERGENCY LIGHTS SYS TEST. REPLACED THE BATTERY IAW AMM 33-51-38, OPS CHECKED GOOD.
2015
Part: COFFEEMAKER — ODOR (GALLEY) · airframe 62,498 hrs · 23,347 cycles
ACFT DIVERTED. ODOR IN AFT GALLEY. PULLED CIRCUIT BREAKERS TO COFFEEMAKERS WITH NO EFFECT. NOTED ODOR AT AFT GALLEY CIRCUIT BREAKER PANEL SO SECURED GALLEY/CABIN POWER FROM FLIGHT DECK. ODOR DISSIPATED. ELECTRICAL ODOR INSPECTION PERFORMED. DURING COFFEEMAKER TEST, FOUND MACHINE WITH SN 243161411, WARMER PLATE WIRING AREA WITH STRONG BURNING ODOR. REPLACED BOTH AFT COFFEEMAKERS. NO ODOR WITH NEW MACHINES.
Part: FLOOR SUPPORT — CORRODED (FRAMES 64-66) · corrosion level 2 · airframe 62,362 hrs · 23,301 cycles
AFT WET AREA FLOORBEAM 765 FRAME 64-FRAME 66 HAS CORROSION ON UPPER SURFACE. REF NON-ROUTINE 440271-22354. R & R FLOORBEAM IAW SRM 51-72-11, 51-44-11.
Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 62,312 hrs · 23,287 cycles
NUMEROUS EMERGENCY LIGHTS OUT THROUGHOUT ACFT. FOUND EMERGENCY LIGHT POWER SUPPLY 11WL FAILED. R & R EMERGENCY LIGHT POWER SUPPLY IAW AMM 33-51-38 AND BATTERY PACK IAW AMM 33-51-38. OPS CHECKS GOOD.
Part: POWER SUPPLY — FAILED (EMERGENCY LIGHTS) · airframe 62,089 hrs · 23,196 cycles
DURING MAINTENANCE, MULTIPLE SEAT EMERGENCY LIGHTS FOUND INOPERATIVE. R & R EPSU AT POSITION 11WL IAW AMM 33-51-38-400-001-A. OPS CHECK GOOD.
Part: CONNECTOR — DISCONNECTED (EMERGENCY LIGHTS) · airframe 61,166 hrs · 22,846 cycles
EMERGENCY LIGHT SYS TEST FAILED, FWD EXT LOAD FAULT. FOUND R-1 DOOR CONNECTOR ON FRONT OF SLIDE PACK PARTIALLY DISCONNECTED. CONNECTED, EMERGENCY SYS LIGHT TEST OK. REF AMM 33-51-00.
Part: POWER SUPPLY — FAILED (EMERGENCY LIGHT) · airframe 60,356 hrs · 1,589 cycles
DURING MAINTENANCE CABIN EMERGENCY LIGHTS INOPERATIVE AT SEAT ROWS 3, 5, 7, 9, 15, 23, 25C. APPLIED TSM 33-57-00-810-801A, FOUND PSU (11WL) UNIT FAULT. R & R EMERGENCY PSU (11WL) OPS CKD OK IAW 33-57-38. CABIN EMER. LIGHTS OPS CKD NORMAL IAW 33-57-00.
Part: POWER SUPPLY — FAILED (EMERGENCY LIGHT) · airframe 22,407 hrs · 59,851 cycles
ON MAINTENANCE CHECK FOUND EPSU 11WL UNIT FAULTED. EMERGENCY PATH LOW LEVEL LIGHTS INOPERATIVE EVERY OTHER SEAT. R & R EPSU 11 WL IAW AMM 33-51-38. OPS CHECK GOOD.
Part: EPSU — NO TEST (EMERGENCY LIGHT) · airframe 59,769 hrs · 22,382 cycles
DURING MAINTENANCE, THE RED OVERWING EMERGENCY EXIT LIGHT IS NOT WORKING. R & R ESPU & BATTERY PACK IAW AMM 33-51-38. ALL EMERGENCY LIGHTS NOW CHECK OK. ADDITIONAL PART REPLACED, DIEHL, PN 3214-31, SN 767628, TAT 2218, TAC 816, TIME SINCE 2218.
Part: EPSU — NO TEST (EMERGENCY LIGHTS) · airframe 59,664 hrs · 22,342 cycles
DURING WEEKLY CHECK EMERGENCY LIGHT SYS TEST FAILED AND SOME CABIN RT EMERGENCY LIGHT FOUND INOPERATIVE. R & R EMERGENCY LIGHT POWER SUPPLY AT 12WL IAW AMM 33-51-38. EMERGENCY LIGHT CHECKED OK. IN ADDITION EMERGENCY LIGHT SYSTEM TEST FAILED AND SOME AT THE FORWARD CABIN LT SIDE, 11WL, FOUND INOPERATIVE. PERFORMED T/S IAW TSM 33-51-00-810-801-A. R & R POWER SUPPLY, SN 2879 AT POSITION 11WL WITH TOTAL HOURS 53957, TOTAL CYCLES 20076, TIME SINCE 67. OPS CHECK OK.
Part: EPSU — FAILED (EMERGENCY LIGHTS) · airframe 59,627 hrs · 22,328 cycles
DURING HEAVY MAINTENANCE CHECK, EMERGENCY EXIT LIGHTS ON SEATS 15 AND 19 DID NOT ILLUMINATE. R & R EPSU AT 11WL IAW AMM 33-51-38-000-001 AND AMM 33-51-38-400-001-A. OPS CHECK GOOD.
Part: EPSU — FAILED (EMERGENCY LIGHTS) · airframe 59,384 hrs · 22,229 cycles
DURING THE WEEKLY CHECK, EMERGENCY LIGHT TEST FAILED ON LT EPSU AT FIN 11WL. R & R EMERGENCY LIGHT EPSU AT FIN 11WL IAW AMM 33-51-38. LIGHT CHECKED OK.
2014
Part: CONNECTOR — UNSECURE (EMERGENCY LIGHTS) · airframe 58,554 hrs · 21,932 cycles
ON MAINTENANCE CHECK, THE EMERGENCY LIGHT TEST HAD AFT LT EXTERNAL LOAD FAULT MESSAGE. FOUND L-2 DOOR SLIDE CONNECTOR ON SLIDE PACK NOT FULLY CONNECTED. CLEANED PLUG AND RE-CONNECTED. EMERGENCY LIGHT TEST OK. NO FAULTS REF. AMM 33-51-00.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 57,550 hrs · 21,566 cycles
DURING MAINTENANCE CHECK, FOUND RT EMERGENCY POWER SUPPLY UNIT FAILED THE EMERGENCY LIGHT TEST. R & R RT EPSU AND BATTERY IAW AMM 33-51-38, OPS CHECKED OK.
Part: POWER SUPPLY — NO TEST (EMERGENCY LIGHT) · airframe 57,550 hrs · 21,566 cycles
DURING MAINTENANCE CHECK, FOUND RT EMERGENCY POWER SUPPLY UNIT FAILED EMERGENCY LIGHT TEST. R & R RT EPSU AND BATTERY IAW AMM 33-51-38, OPS CHK OK.
2013
Part: FLAP SYSTEM — MALFUNCTIONED · airframe 54,226 hrs · 20,404 cycles
CREW DECLARED AN EMERGENCY AND ACFT DIVERTED DUE TO FCTL FLAPS LOCKED. ALIGNMENT FAULT ECAM ON LANDING. INSPECTED INTEGRITY OF LT FLAP MECHANISM IAW TSM 27-51-00. NO FAULTS NOTED. RESET SYS, ACCOMPLISHED TEST OF FLAPS IAW AMM 27-54-00. NO FAULTS NOTED. OK FOR CONTINUED SERVICE.
Part: BOTTLE — EMPTY (L1 DOOR ASSIST) · airframe 54,222 hrs · 20,401 cycles
DURING MAINTENANCE CHECK, FOUND L1 DOOR ASSIST BOTTLE AT 0 PSI. R & R L1 DOOR ASSIST BOTTLE DIAPHRAGM AND SERVICED BOTTLE. NO LEAKS NOTED REF 52-11-14. ACFT RESTORED TO NORMAL CONFIGURATION.
Part: OUTFLOW VALVE — FAILED (CABIN PRESSURE) · airframe 53,328 hrs · 20,100 cycles
AIR RETURN TO DEPARTURE DUE TO VENT SKIN VALVE ECAM FAULT AND ACFT COULD NOT PRESSURIZE. IAW TSM 21-26-00-810-804A, R & R SKIN AIR OUTLET VALVE IAW AMM 21-26-53. CHECKED NORMAL.
2011
Part: TACHOMETER — SHEARED (NR 2) · airframe 46,553 hrs · 17,702 cycles
FLT 824 SDQ-JFK, CREW DECLARED EMERGENCY DUE TO ECAM MESSAGE "BRAKES" AUTO BRK FAULT "BRAKES RELEASED". THE TECHNICIAN FOUND NR 2 TACHOMETER DRIVE SHAFT SHEARED. REMOVED AND REPLACED TACH AND DRIVE SHAFT IAW AMM 32-42-57-04. OPS CHECK GOOD.
Part: FUEL — CONTAMINATED (WING TANK) · airframe 45,703 hrs · 17,425 cycles
FLT 318 OAK-IAD, CREW EXECUTED AN EMERGENCY LANDING DUE TO FUEL LOSS OF 1000 LBS UNACCOUNTED FOR ON LEFT SIDE OF AIRCRAFT. COULD NOT ISOLATE LEAK BUT IT STOPPED AFTER CENTER TANK CLOSED. COULD BE APU OR CENTER TANKS. TECHNICIAN SUMPED L&R WING TANKS PER AMM 12-11-28. FOUND 1+ QTS WATER IN EACH WING TANK (INNER). CTR TANKS NORMAL. NO FUEL LEAKS NOTED AT THIS TIME. INTERROGATION OF CFDS (FQIC) NORMAL. OK FOR SERVICE.
Part: UNKNOWN — MALFUNCTIONED (FUEL SYSTEM) · airframe 45,235 hrs · 17,265 cycles
FLT 415 BOS-SAN, HAD AN AIR RETURN TO BOSTON DUE TO CENTER TANK PUMP 1 FAILED AFTER SLAT RETRACTED. PERFORMED OPS CHECK OF NR 1 CENTER TANK PUMP PER AMM 28-21-51. OPS CHECK NORMAL. SUSPECT IMPROPER CONFIGURATION OF AIRCRAFT DUE TO MEL 28-21-02 CONDITION 1 BEING APPLIED TO THE NR 2 CENTER TANK PUMP.
2009
Part: UNKNOWN — ODOR (CABIN) · airframe 38,055 hrs · 14,634 cycles
FLT 708, SJU-JFK, FLT CREW REPORTED SMELL COMING FROM ROW 9 AREA AND DISSIPATED WHEN LTV SYS WAS TURNED OFF. COMPLIED WITH TSM TASK 24-00-00-81-823. NO DEFECTS NOTED. INSPECTED SEAT TO SEAT CABLE AND DPCU CABLE 7-9 ABCDEF, UNABLE TO IDENTIFY ANY DAMAGE, TSM TASK 23-39-00-810-801 ACCOMPLISHED. ALL SYS OPS NORMAL.
Part: ENTERTAIN SYS — ODOR · airframe 38,055 hrs · 14,634 cycles
LIVE TV SYSTEM ALL, FLT CREW REPORTED ODOR COMING FROM ROW 9 AREA AND DISSAPATED WHEN LIVE TV SYSTEM WAS TURNED OFF. COMPLIED WITH TSM TASK 24-00-00-810-823. NO DEFECT NOTED. TSM TASK 23-39-00-810-801 NEEDS TO BE ACCOMPLISHED ON LIVE TV SYSTEM. LIVE TV SYSTEM DEACTIVATED AND PLACED ON MEL 25-22-03 COND 1 CAT D PER MCC. LIVE TV C/B B8 OF 2000V4 PULLED AND COLLAED MCC NOTIFIED MX-4 UPDATED PLACARD INSTALLED. INSPECTED SEAT TO SEAT CABLE, VDU CABLE, AND DPCU CABLE ROW 7-9 ABCDEF UNABLE TO IDENTIFY ANY DAMAGE OR ABNORMAL. ALL LIVE TV SYSTEM OPS NORMAL REACTIVATE SYS PER TSM 23-39-00-810-801 MDDR 62587, CLEARED MX-4 UPDATED PLACARD REMOVED MCC NOTIFIED.
Part: COMPUTER — FAULTY (NR 1) · airframe 37,248 hrs · 14,335 cycles
FLT 1756 - SJU-FLL - WHEN SELECTING FLAPS 2 RECEIVED F/CTL FAULT ECAM. FLAPS WERE STUCK AT 0. COMPLETED ECAM AND QRH AND LANDED PER QRH/DISPATCH/MTC IN THAT CONFIGURATION. PERFORMED TROUBLESHOOTING AS PER TSM 27-51-00. DURING TROUBLESHOOTING FOUND THAT ALL FAULTS AND FAILURES FOLLOWED SFCC ORIGINALLY INSTALLED IN POSITION NR 1 AS IT WAS SWAPPED MULTIPLE TIMES TO POS 2 AND BACK. REMOVED & REPLACED SFCC NR 1 IAW AMM 27-51-34. OPS CHECKS GOOD. NO FAULTS NOTED.
Part: THERMOSTAT — FAILED (BLEED AIR SYS) · airframe 37,078 hrs · 14,271 cycles
FLT 180, PHX-JFK, CRUISING AT 37,000, BLEED 2 THEN BLEED 1 FAULTED (BLEED AIR SUPPLY SYSTEMS). REMOVED AND REPLACED NR 1 ENG BLEED AIR SUPPLY SYS THERMOSTAT IAW 36-11-43-04, LEAK CHECK & OPS CHECKS OK.
Part: MONITOR — FAILED (CABIN) · airframe 35,966 hrs · 13,849 cycles
FLT 204, LGB-JFK, SEAT 16A TV INOP, BURNING SMELL PRIOR TO FAILURE. SEAT BOX WAS WARM TO TOUCH. ACCOMPLISHED INSPECTION PER 24-00-00-810-823. NO DEFECTS NOTED.
2007
Part: ACTUATOR — CONTAMINATED (T/E FLAP) · airframe 31,290 hrs · 12,151 cycles
FLT 352, BUR-JFK. DURING CONFIGURATION FROM FLAPS 1 TO 2 F/CTL FLAPS LOCKED ECAM. WING TIP BRAKE ON. REMOVED AND REPLACED NR 1 & 2 RT WING FLAP ACTUATORS, RIG/ADJUST OF RT FLAP OPERATIONAL TEST GOOD IAW 27-54-49 AND 27-54-00-05.
Part: ACTUATOR — CONTAMINATED (T/E FLAP) · airframe 31,290 hrs · 12,151 cycles
FLT 352, BUR-JFK. DURING CONFIGURATION FROM FLAPS 1 TO 2 F/CTL FLAPS LOCKED ECAM. WING TIP BRAKE ON. REMOVED AND REPLACED NR 1 & 2 RT WING FLAP ACTUATORS. RIG/ADJUST FLAP OPERATIONAL TEST GOOD IAW 27-54-49 AND 27-54-00-05.
Part: POWER SUPPLY — NO TEST (EMERGENCY LIGHTS) · airframe 29,342 hrs · 11,502 cycles
UPON TEST L1 & R1 EMERGENCY LIGHTS DID NOT WORK. REPLACED POWER SUPPLY IAW AMM 33-51-38-04. OPS CHECK NORMAL UPON TEST.
Part: POWER SUPPLY — NO TEST (EMERGENCY LIGHTS) · airframe 29,342 hrs · 11,502 cycles
UPON TEST ROW 10 ABC EMERGENCY LIGHTS DID NOT WORK. REMOVED AND REPLACED POWER SUPPLY (12WL) PER AMM 33-51-38-04. OPS CHECK OK.
2005
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHT) · airframe 22,746 hrs · 9,193 cycles
DURING EMERGENCY LIGHT SYSTEM TEST. EPSU EMER. L DISPLAYED. REMOVED AND REPLACED EPSU (11WL) BATTERY PACK IAW AMM 33-51-38. SYSTEM OPS CHECK GOOD.
Part: ENTERTAIN SYS — MALFUNCTIONED (CABIN) · airframe 19,961 hrs · 8,215 cycles
FAINT BURNING SMELL FOR SHORT DURATION SMELLED ON FRONT GALLEY. COMPLIED WITH INFO NOTICE 2004-T023TR. ALSO COMPLIED WITH TSM TASK 24-00-00-801-832. LTV FOUND TO BE INOP ALL CHANNELS, MEL'D LTV SYS (REF L/P 88796 ITEM 1). NO OTHER SMELLS OR SMOKE NOTED DURING TEST. UPON ARRIVAL AT JFK ACCOMPLISHED INFO NOTICE 2004-T023 TR, FOUND TVS WORKING SATISFACTORY AND AT THIS TIME NO BURNING SMELL NOTICED. MEL CLEARED. NO COMPONENTS CHANGED.
2004
Part: ELECTRICAL BOX — MALFUNCTIONED (ENTERTAIN SYS) · airframe 17,254 hrs · 7,260 cycles
3O MINS INTO FLIGHT FA NR 1 REPORTED AN ODOR EMITTING FROM ROW 1-4, TURNED LIVE TV MASTER SWITCH TO OFF, SMELL WAS GONE AFTER 3 MIN. TV'S WERE WORKING PRIOR TO TURNING THE MASTER SWITCH OFF. COMPLIED WITH INFO NOTICE 2003-T050TR A. NO ABNORMALITIES WERE FOUND. REMOVED AND REPLACED SEB'S AT 2B & 2E FOR PRECAUTIONARY MEASURE IAW CMM 23-39-00. SYSTEM OPERATION SATISFACTORY. SEB S/N 5460 & 2017.
2003
Part: PROXIMITY SENSOR — MALFUNCTIONED (MLG) · airframe 14,310 hrs · 6,220 cycles
LANDING GEAR MALFUNCTIONED ON FIRST ATTEMPT. SECOND ATTEMPT LANDING GEAR FUNCTIONED PROPERLY. UPON LANDING ECAM L/G SYS DISAREE. CHECKED LGCIU 1 AND 2 FOR LAST LEG HISTORY. FOUND RT DOOR PROX FAULT ON LGCIU NR 2. CHECKED SENSOR 34GA REF TSM TASK 32-31-00-810-816 STEP 3. FAULT NOT CONFIRMED. BITE CHECKED LGCIU 1AND 2 OPERATES NORMALLY. OK FOR FURTHER SERVICE.
Part: WIRE HARNESS — NICKED (EMERGENCY LIGHT) · airframe 13,760 hrs · 6,172 cycles
EMMERGENCY LIGHT HARNESS AT LT ROW LOCATION 3, 6, 8, 10, 12, 14, 18, 22 AND 26 HAS NICKS AND POSSIBLE DAMAGE. REPAIRED HEAT SRINK TUBING IAW ESPM 20-53-29 AT 6 LOCATIONS AND REPLACED HARNESS AT ROW 14, 22, 26.
Part: BATTERY — DISCHARGED (CABIN) · airframe 13,243 hrs · 5,855 cycles
DURING WEEKLY CHECK FOUND AFT EPSU BATTERY FAILING TEST. REPLACED LEFT AFT BATTERY PER AMM; TEST OK.
2002
Part: TUBE — LEAKING (HYD SYSTEM) · airframe 11,287 hrs · 5,143 cycles
APPROX 1 HOUR AFTER DEPARTURE FROM JFK, FLT. 91, CREW REPORTED GREEN HYD SYSTEM QTY LOW. APPROX 1 HOUR LATER CREW REPORTED ECAM GRN RES LOW QTY. CREW C/W ECAM ACTION, DISCUSSED OAK ARRIVAL ACTION. GRAVITY GEAR EXTENSION, ALT BRAKES AVAILABLE AND HAVING A/C MAINT MEET AIRCRAFT AT END OF RUNWAY WITH TUG AND TOWBAR. CREW AS PRECAUTIONARY DECLARED EMERGENCY. FOUND EDP CASE DRAIN LINE LEAKING IN PYLON. REPLACEMENT LINE NOT AVAILABLE LOCALLY. PERMASWAGE OR RYNGLOC PERMANENT REPAIR NOT AN OPTION DUE TO SPACE CONSTRAINTS. C/W TEMP FLEX LINE REPAIR IAW AMM 20-23-11-300-004. PERMANENT REPAIR DUE AT NEXT -A- CHECK AND DAILY REINSPECT REQUIRED.
Part: SHOCK ABSORBER — MISALIGNED (NOSE GEAR) · airframe 10,723 hrs · 4,892 cycles
FLT #3, BUF to JFK, Landing gear shock absorber fault Wheel Nose wheel Steer fault ECAM after take off. Gear would not go up. Nose gear 90 degree on landing with failure.Inspected nose gear, Removed and replaced shockstrut assy per AMM 32-21-13-401 and AMM 32-21-13-000-001, Ops and leak check ok, performed normal and alt gear operation, all normal and OK for service as per ref AMM 32-21-16-000-002. Note: Crew reported that after take off from BUF gear would not retract. research of PFR data showed L/G shock absorber fault with associated NLG prox sensor faults identified by both LGCIU 1 and 2. Also a NW Steering fault was identified by BSCU 1 and 2.Aircraft landed at JFK iaw FCOM procedures 3.02.32 P1. N
Part: POWER SUPPLY — FAILED (CABIN) · airframe 9,028 hrs · 4,226 cycles
AT JFK, ON WEEKLY EMERGENCY LIGHT SYSTEM TEST HAD EPSU LEFT FAILURE. REMOVED AND REPLACED LEFT EPSU AND GROUND OPS CHECKED OK PER MM 33-51-00.
Part: TACHOMETER — DAMAGED (NR 1 BRAKE) · airframe 10,534 hrs · 4,212 cycles
AT JFK FLT 77, EXPERIENCED BRAKE ECAM ON T/O ROLL AT LOW SPEED. ABORTED T/O AND RETURNED TO GATE. T/S FOUND NR 1 TACH SPLINE DAMAGED & HUB CAP, ALSO NR 3 HUB CAP SPLINE FAN TACH. REMOVED AND REPLACED NR 1 TACH, NR 1 HUB CAP AND NR 3 HUB CAP PER AMM 32-42-68, 32-38-51, PERFORMED OPS CHECK PER AMM 32-42-00, SYSTEM OPS CHECK GOOD.
2000
Part: SKIN — PUNCTURED (FUSELAGE)
AT JFK ON WALK AROUND INSPECTION, FOUND PUNCTURE ON FORWARD LEFT FUSELAGE BELOW CAPTAINS FIXED WINDOW. REMOVED EXISTING FASTENERS, MANUFACTURED REPAIR DOUBLER AND PICKED UP NEW FASTENERS IN REPAIR PER SRM 53-00-11. INSTALLED DOUBLER AS PER SRM 53-00-11. (M)