N504VJ

BOMBARDIER INC BD-700-1A11 · 2013 · Fixed-wing multi-engine · 2 engines · 8 seats · Valid Registration

Registered owner: BANK OF UTAH TRUSTEE, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
XOJET Aviation LLC (AWKA)Certificate holder—Matched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

2 reports on file, 2019-02-28 – 2026-08-31.

FLUID LOSS; WARNING INDICATION · 2026-08-31 Matched by certificate designator
ATA 2910

Part: HYDRAULIC LINE — CRACKED (ZONE 400) · airframe 9,667 hrs · 3,751 cycles

NR 1 HYD LEAK IN AIR. UNEVENTFUL LANDING. HYD FLUID NOTICED ON BOTTOM OF AFT FUSELAGE. COMPLIED WITH CAMP CARD 20260831-23. INSPECTED AREAS WITH HYD FLUID & FOLLOWED TO AFT EQUIP BAY. LARGEST CONCENTRATION OF FLUID AROUND LT HYD FILTER MANIFOLD. TORQUED HYD LINES IN AREA IAW SPM 20-30-00-400-801. CLEANED IAW SPM 51–25–00–110–801 & SERVICED HYD SYS NR 1 IAW AMM 12-12-00-611-801. PRESSURIZED SYS NR 1 IAW AMM 29-10-00-862-801. NO LEAK NOTED. PRESSURIZED EDP IAW AMM 29-12-01-710-801. FOUND LEAK AT LT FIREWALL SHUTOFF VALVE. REPLACED LT SHUTOFF VALVE IAW AMM 29-12-33-000-801, & 29-12-33-400-801. OPS TESTED GOOD, NARROWED DOWN LEAK FROM CRACK ON LT PRESS LINE AFT OF SHUTOFF VALVE. REPLACED HYD LINE IAW SPM 20-30-00-910-807, & SPM 20-30-00-400-801. NO LEAKS NOTED. REINSTALLED ORIGINAL SHUTOFF VALVE IAW AMM 29-12-33-000-801, & 29-12-33-400-801. OPS & LEAK TEST GOOD. HYD SYS NR 1 SERVICED IAW AMM 12-12-00-611-801.

Source: SDR U5QA202608310179
FALSE WARNING · 2019-02-28 Matched by certificate designator
ATA 5270

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 3,481 hrs · 1,212 cycles

AFTER DEPARTING, UPON INITIAL CLIMB OUT, AT 1,000, WE HEARD SOME NOISE FROM THE DOOR AREA, AS IF SOMETHING HAD BECOME UNLATCHED, AND WE SIMULTANEOUSLY SAW A YELLOW DOOR INDICATION ON THE STATUS SYNOPTIC PAGE. WE DECLARED AN EMERGENCY, CONTINUED OUR CLIMB TO 2,000', WHERE WE ENTERED A DOWNWIND LEG FOR LANDING ON THE RUNWAY OF OUR CHOOSING, AS WE WERE CLEARED TO LAND ON ANY RUNWAY BY THE CONTROL TOWER. WE LANDED WITH NO DIFFICULTIES. AIRCRAFT WAS REMOVED FROM SERVICE AND MAINTENANCE INSPECTED THE MAIN ENTRANCE DOOR (MED) WITH NO DISCREPANCIES NOTED. OPERATIONAL CHECKED SEVERAL TIMES WITH NO DEFECTS NOTED. ALL WORK PERFORMED IAW AMM 52-11-00-010-801 & 52-11-0-410-801. NOTE: CREW MENTIONED TO MAINTENANCE THAT THE MED HANDLE MAY NOT HAVE BEEN FULLY DOWN. AIRCRAFT HAS FLOWN 14 ADDITIONAL LANDINGS TO DATE WITH NO FURTHER FAULTS NOTED.

Source: SDR KKVA20190305002