N509AA

BELL 407 · 2006 · Valid Registration

Registered owner: GM LEASING COMPANY LLC, LA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

B · 2025-05-14 Matched by certificate designator
ATA 2810

DURING FLIGHT, A DISTINCT FUEL SMELL COMING FROM AFT RIGHT SEAT AREA. SMELL WAS STRONG ENOUGH TO MAKE MEDICAL CREW MEMBER WHO IS SITTING IN THAT SEAT NAUSEOUS. PILOT DID NOT SENSE ANY FUEL FUMES. AMT REMOVED STRUCTURAL ACCESS PANELS FOR FUEL SHUT OFF VALVE R/H COMPARTMENT TO INVESTIGATE THE FUEL SMELL. NOTED FUEL SMELL COMING FROM FUEL SHUT OFF VALVE R/H COMPARTMENT. NO ACTIVE LEAK NOTED AT THIS TIME. THE AMT REMOVED DEBRIS OBSTRUCTING VENT PORT OF SHUT OFF VALVE. INSTALLED AND SEALED QUANTITY 2 STRUCTURAL ACCESS PANELS WHICH WERE NOT SEALED PROVIDING MINIMAL FUME PROTECTION. A CHECK FLIGHT WAS PERFORMED WITH NO FUEL FUMES.

Source: SDR 454A250514115915 · FAA SDRS
B · 2025-03-26 Matched by certificate designator
ATA 2120

JUST A FEW MILES AFTER TAKING OFF FROM BASE, PIC ADVISED OVER RADIO THAT THEY WOULD BE HEADED BACK TO KGRI DUE TO THE CREW SMELLING FUMES IN THE CABIN. ONCE LANDED PIC CONTACTED OCC AND ADVISED CREW WAS SMELLING OIL/EXHAUST LIKE FUMES AND IT STARTED TO MAKE THEM NAUSEOUS. PIC ADVISED SMELL WAS ONLY IN CABIN AREA AS HE DID NOT SMELL ANYTHING IN THE COCKPIT. THE MECHANIC CLEANED AND INSPECTED THE AFT AC SYSTEM DUCTS AND EVAPORATOR. OPERATIONAL CHECK WAS PERFORMED WITH NO DEFECTS NOTED. AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR 454A2025040105537 · FAA SDRS