N546DS

SUSTAINABLE SKYLINES AERO SKY · Rotorcraft · 5 engines · 0 seats · Valid Registration

Registered owner: SOUTHERNAG DRONE SERVICES LLC, GA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

8 reports on file, 2003-06-16 – 2004-01-27.

OTHER · 2004-01-27 Matched by certificate designator
ATA 3350

Part: LIGHT — CRACKED (ZONE 100) · airframe 451 hrs · 465 cycles

PDX- ROW 9 RT SIDE, ROW 13 LT HAND AND RT SIDE EMERGENCY ESCAPE PATH LIGHTING COVER IS CRACKED. REMOVED AND REPLACED EMERGENCY ESCAPE PATH LIGHTING.

Source: SDR QXEA200400088
FALSE WARNING · 2003-12-19 Matched by certificate designator
ATA 5270

Part: SPRING — LOOSE (ZONE 800) · airframe 373 hrs · 382 cycles

DESCENDING OUT OF 3500 FT, THE FUSELAGE DOOR MASTER WARNING LIGHT KEPT GOING FROM ON TO OFF. THE DOORS PAGE INDICATED THE AFT PAX DOOR. MAINTENANCE INSPECTED THE AIRCRAFT AND CLEANED AND LUBED THE SPRING PORTION OF THE PROX SENSOR. THE SPRINGS ON EXTERNAL DOOR HANDLE MECHANISM WERE FOUND TO HAVE NO TENSION. THE SPRINGS WERE REPLACED, OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR QXEA200301573
WARNING INDICATION · 2003-11-16 Matched by certificate designator
ATA 2420

Part: PIN — WORN (ELECTRICAL SYS) · airframe 198 hrs · 205 cycles

PDX- ON FLIGHT 9852 IN CRUISE NR 2 AC GENERATOR CAUTION LIGHT ILLUMINATED. RESET NR 2 AC GENERATOR PER CHECKLIST. NR 2 AC GENERATOR CAUTION LIGHT ILLUMINATED AGAIN THEN FLICKERED RANDOMLY. SHUT DOWN NR 2 AC GENERATOR AS BY CHECKLIST AND LEFT IT SHUT DOWN FOR REMAINDER OF FLIGHT. NOTICED PIN E INSIDE ELECTRICAL CONNECTOR 3421-P16-2 IS WORN. REPLACED PIN. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.

Source: SDR QXEA200301440
WARNING INDICATION · 2003-11-12 Matched by certificate designator
ATA 2450

Part: CONTACTOR — FAILED (ELECTRICAL SYS) · airframe 188 hrs · 193 cycles

SEA- ON FLIGHT 2323 NR 2 AC GENERATOR CAUTION ILLUMINATED ON APPROACH, IT WOULD NO RESET PER CHECKLIST. REMOVED NAD REPLACED AC CONTACTOR BOX. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.

Source: SDR QXEA200301421
WARNING INDICATION · 2003-11-03 Matched by certificate designator
ATA 2421

Part: GENERATOR — MALFUNCTIONED (NR 2) · airframe 161 hrs · 166 cycles

SEA- ON FLIGHT NUMBER 2323, AFTER LANDING, NR 2 AC GENERATOR CAUTION LIGHT CAME ON. RESET PER CHECKLIST, WOULD NOT COME BACK ONLINE. REMOVED AND REPLACED NR 2 AC GENERATOR. OPERATIONAL TEST GOOD. AIRCRAFT RETURNED TO SERVICE.

Source: SDR QXEA200301393
WARNING INDICATION · 2003-11-02 Matched by certificate designator
ATA 2421

Part: GENERATOR — MALFUNCTIONED (NR 2) · airframe 159 hrs · 163 cycles

PDX- NR 2 AC GENERATOR OCCASIONALLY ILLUMINATES. RESETS OKAY PER ABNORMAL CHECKLIST. FOUND FAULTS 2A AND 26. CLEARED FAULTS. NO PARTS REPLACED. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.

Source: SDR QXEA200301384
NO TEST · 2003-07-05 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 115 hrs · 116 cycles

SEA- FORWARD EMERGENCY POWER BATTERY PACK LOW. REMOVED AND REPLACED FORWARD EMERGENCY POWER BATTERY PACK. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.

Source: SDR QXEA200300784
FALSE WARNING · 2003-06-16 Matched by certificate designator
ATA 5270

Part: PROXIMITY SWITCH — STUCK (CARGO DOOR) · airframe 40 hrs · 21 cycles

SUP - PDX - FLIGHT 2388 - AIRCRAFT RETURNED TO FIELD WHEN AFTER TAKE-OFF THE CREW RECEIVED A FORWARD BAGGAGE DOOR WARNING AND ALSO NOTED THAT THE AIRCRAFT WOULD NOT PRESSURIZE. MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND THE FORWARD PROXIMITY SWITCH STUCK. THE SWITCH WAS CLEANED AND LUBED, AND THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE. NO PARTS WERE REPLACED.

Source: SDR QXEA200300738