N548GJ

BOMBARDIER INC CL-600-2C11 · 2009 · Fixed-wing multi-engine · 2 engines · 55 seats · Valid Registration

Registered owner: SKYWEST AIRLINES INC, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

17 reports on file, 2021-08-03 – 2026-10-26.

OTHER · 2026-10-26 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (ZONE 100) · corrosion level 2 · airframe 36,916 hrs · 27,261 cycles

CORROSION ON STRINGER 26R BTWN BS 280 - 333. INSTALLED RIVETS ON ATTACH FLANGE OF STRINGER 26RH BTWN BS 280 - 333 IAW SRM 51-42-06.

Source: SDR N6WA2026102903
OTHER · 2026-10-26 Matched by certificate designator
ATA 5313

Part: STRINGER SPLICE — CORRODED (ZONE 100) · corrosion level 2 · airframe 36,916 hrs · 27,261 cycles

CORROSION ON STRINGER SPLICE 26R AT BS 333. LOCATED, & DRILLED NEW HOLES ON THE STRINGER SPLICE 26R AT BS 333 IAW SRM 5140-11. INSTALLED THE STRINGER SPLICE IAW SRM 51-42-06.

Source: SDR N6WA2026102902
OTHER · 2026-10-26 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (ZONE 100) · corrosion level 2 · airframe 36,916 hrs · 27,261 cycles

CORROSION OUT OF LIMITS ON STRINGER 25R BTWN BS 280 - 333. REPLACED AND INSTALLED RIVETS ON ATTACH FLANGE OF STRINGER 25R IAW SRM 51-42-06.

Source: SDR N6WA2026102901
OTHER · 2026-10-21 Matched by certificate designator
ATA 5320

Part: ANGLE — CRACKED (ZONE 200) · airframe 36,916 hrs · 27,261 cycles

CRACK ON ANGLE BETWEEN DIAPHRAM AND FRAME FS 909. REPAIRED LT ANGLE BETWEEN DIAPHRAGM AND FRAME AT BS 909 IAW EO C550-53MLR.002 RO.

Source: SDR N6WA2026102301
OTHER · 2026-10-20 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (ZONE 200) · corrosion level 2 · airframe 36,916 hrs · 27,261 cycles

CORRSION ON SEAT TRACK RT, BTWN BS 364 - 773 OUT OF LIMITS. REPLACED RT SEAT TRACKS BETWEEN FS 364 - 773 IAW SRM 53-31-49.

Source: SDR N6WA2026102302
OTHER · 2026-10-20 Matched by certificate designator
ATA 5320

Part: CHANNEL — CORRODED (ZONE 100) · corrosion level 2 · airframe 36,916 hrs · 27,261 cycles

CORROSION ON LOWER ATC 1 CHANNEL BETWEEN BS 349 - 364, STRINGERS 26R - 25R. REMOVED & REPLACED LOWER ATC 1 CHANNEL BTWN BS 349. BS 364 BTW STGR 25R - 26R IAW SRM 51-42-06.

Source: SDR N6WA2026102303
WARNING INDICATION · 2026-04-20 Matched by certificate designator
ATA 5270

Part: DOOR — DAMAGED (NLG) · airframe 36,052 hrs · 26,440 cycles

GEAR DISAGREE WARNING MESSAGE IN FLIGHT - EMERG LANDING. UPON INSPECTION, FOUND NLG AFT DOOR LH HINGE FITTING HARDWARE MISSING, AND FOUND AFT NLG DOOR DAMAGED. REMOVAL OF NLG AFT DOOR REQUIRED. NLG EXTENSION AND RETRACTION REQUIRED. REF LOG PAGE 570479 DISC #2.

Source: SDR N6WA2026042102
Earlier reports · 2021–2025 · 10 reports

2025

OTHER · 2025-08-19 Matched by certificate designator
ATA 3350

Part: LIGHT — OUT OF POSITION (ZONE 200) · airframe 34,795 hrs · 25,236 cycles

EPL STRIP AT 11B MIGRATED. ADJUSTED AND SECURED EPL STRIP AT 11B IAW CRJ AMM 33-55-01. OPS CHECK GOOD.

Source: SDR N6WA2025082201
FALSE WARNING · 2025-07-14 Matched by certificate designator
ATA 2611

Part: SMOKE WARNING — FALSE ACTIVATION (ZONE 900) · airframe 34,601 hrs · 25,059 cycles

SMOKE AFT LAV EMERGENCY RETURN FLIGHT. INSPECTED AND OPS CHECKED#1 AND #2 PACKS AND GALLEY HEATER FOR PROPER OPERATION. OPS CHECK GOOD, NO FAULTS FOUND AT THIS TIME IAW CRJ AMM 21-51-00 AND 21-23-64. DETERMINDED DRYOUT PROCEDURE WAS NOT COMPLETED DURING RECOVERY PRESSURE WASH.

Source: SDR N6WA2025071401
OTHER · 2025-05-08 Matched by certificate designator
ATA 5320

Part: ANGLE — CRACKED (ZONE 200) · airframe 34,308 hrs · 24,781 cycles

FWD RADIUS OF INTERCOSTAL CRACKED AFT OF FS220.00 AND STGR13R. REPAIRED INTERCOSTAL FWD RADIUS AT FS220.00 AND STGR13R IAW REO 670-53-11-1979 AND EO-C550-53MR-024-O

Source: SDR N6WA2025050901
OTHER · 2025-05-08 Matched by certificate designator
ATA 5320

Part: BRACKET — CORRODED · corrosion level 2 · airframe 34,308 hrs · 24,781 cycles

CORROSION ON FUSELAGE FLOOR SILL RH BETWEEN FS280-FS295 AT STGR17R. REMOVED AND REPLACED RH FLOOR SILL BETWEEN FS280-FS319 AT STGR17R IAW CRJ SRM 51-42-06 AND CRJ SRM 51-42-10.

Source: SDR N6WA2025050902
WARNING INDICATION · 2025-01-08 Matched by certificate designator
ATA 5270

Part: WARNING MESSAGE — ILLUMINATED (ZONE 800) · airframe 33,780 hrs · 24,282 cycles

PASSENGER DOOR LATCH CAUTION MESSAGE. DEFERRED PAX DOOR INDICATION IAW CRJ MEL 52-70-01 CAT A.

Source: SDR N6WA2025010801

2024

FALSE WARNING · 2024-11-10 Matched by certificate designator
ATA 5210

Part: WARNING MESSAGE — FALSE ACTIVATION (ZONE 800) · airframe 33,466 hrs · 23,993 cycles

PAX DOOR LATCH WARNING CAUTION MESSAGE COMES ON DURING CRUSIE AT FL 350. PERFORMED OPS CHECK OF PAX DOOR IAW CRJ AMM 52-11-00. OPS CHECK GOOD.

Source: SDR N6WA2024111101
OTHER · 2024-02-22 Matched by certificate designator
ATA 2562

Part: ELT — INOPERATIVE (ZONE 100) · airframe 32,292 hrs · 22,766 cycles

PORTABLE ELT BATTERY INOP, R&R PORTABLE ELT BATTERY IAW ARTEX CMM 25-62-30 OPS CHECK GOOD.

Source: SDR N6WA2024022302

2023

OTHER · 2023-02-20 Matched by certificate designator
ATA 7100

Part: COWLING — CORRODED (#1 ENGINE) · airframe 30,965 hrs · 21,394 cycles

#1 ENG INLET LIP IS PITTED, SHOWS SIGNS OF CORROSION. R&R #1 ENGINE INLET COWL IAW CRJ 700 AMM 71-61-01 OPS AND VIBE CHECK GOOD.

Source: SDR N6WA2023022701

2022

OTHER · 2022-09-03 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 30,414 hrs · 20,823 cycles

EMERGENCY EXIT SIGNS ON FWD AND AFT R/H SIDE MID MONUMENTS ARE INOP.

Source: SDR N6WA2022090801

2021

OTHER · 2021-08-03 Matched by certificate designator
ATA 3350

Part: LIGHT — FAULTED (MAIN CABIN) · airframe 29,617 hrs · 20,077 cycles

MAIN CABIN DOOR EMERGENCY LIGHTS OUT. PERFORMED OPS - TEST IAW CRJ 550 AMM 33-51-00 AIRCRAFT OK FOR SERVICE

Source: SDR N6WA20210806301