N549GJ

BOMBARDIER INC CL-600-2C11 · 2009 · Fixed-wing multi-engine · 2 engines · 55 seats · Valid Registration

Registered owner: SKYWEST AIRLINES INC, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

17 reports on file, 2020-07-06 – 2026-08-14.

WARNING INDICATION · 2026-08-14 Matched by certificate designator
ATA 7603

Part: CONTROL VALVE — FAULTED (RT ENGINE) · airframe 37,674 hrs · 28,164 cycles

RT THRUST LEVER WILL NOT ADVANCE ABOVE IDLE WITH ENG RUNNING FOR TAKEOFF. REMOVED AND REPLACED T/R DCV IAW AMM 78-32-01 LEAK AND OPS CHECK GOOD. FAULT PERSISTS. REF LOG PAGE 645688 ITEM 2 FOR CORRECTIVE ACTION.

Source: SDR N6WA2026081701
WARNING INDICATION · 2026-08-12 Matched by certificate designator
ATA 2721

Part: CONTROL UNIT — FAULTED (ZONE 300) · airframe 37,664 hrs · 28,151 cycles

RUDDER LIMITER CAUTION DURING CLIMB (B1 - 233334, 060059). SWAPPED NR 1 AND NR 2 SSCU. OPS CHECKED GOOD IAW AMM 27-61-05. NO DEFECTS NOTED.

Source: SDR N6WA2026081203
Earlier reports · 2020–2024 · 15 reports

2024

WARNING INDICATION · 2024-09-01 Matched by certificate designator
ATA 2760

Part: SPOILER SYS — INOPERATIVE (SPOILERS) · airframe 34,150 hrs · 24,772 cycles

SSCU2 FAULT, AP PITCH TRIM CAUTION, IB FLT SPLRS CAUTION, PITCH FEEL CAUTION, IB GND SPLRS CAUTION, STAB CH 1 INOP, RUD LIMIT FAULT IN FLIGHT. REPLACED SSCU #1 IAW CRJ 550 AMM 27-61-05. OPS CHECKS GOOD.

Source: SDR N6WA2024090104
FALSE WARNING · 2024-08-06 Matched by certificate designator
ATA 5220

Part: DOOR — FALSE INDICATION (ZONE 800) · airframe 34,052 hrs · 24,680 cycles

RIGHT EMERGENCY DOOR CAUTION MESSAGE DURING TAXI. OPEN AND RESECURED RIGHT EMERGENCY OVERWING EXIT PER CRJ550 52-21-00. OPS CHECK GOOD.

Source: SDR N6WA2024080702
OTHER · 2024-07-19 Matched by certificate designator
ATA 5311

Part: BRACKET — CRACKED (ZONE 200) · airframe 34,030 hrs · 24,658 cycles

ANGLE BRACKET LOCATED ON AFT SIDE OF FS220.00 STRINGER 13A ON RH SIDE IS CRACKED. REPAIRED RH INTERCOSTAL AT FS220.00 IAW CRJ REO 670-53-11-1979 AND EO C550-53MR-24.

Source: SDR N6WA2024072201
OTHER · 2024-07-16 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 100) · airframe 34,030 hrs · 24,658 cycles

RH SIDE FS280 BEAM IS CORRODED. REMOVED AND REPLACED RH SIDE FS280.00 BEAM IAW CRJ SRM 51-42-00

Source: SDR N6WA2024071702
OTHER · 2024-07-16 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 200) · airframe 34,030 hrs · 24,658 cycles

LH SIDE FS280 BEAM CORRODED. REMOVED AND REPLACED LH SIDE OF FS280 BEAM IAW CRJ SRM 51-42-00.

Source: SDR N6WA2024071701
OTHER · 2024-02-06 Matched by certificate designator
ATA 1100

Part: PLACARD — MISSING (SERVICE DOOR) · airframe 33,475 hrs · 24,063 cycles

SERVICE DOOR LUMINESCENCE STRIP MISSING ON RH SIDE. INSTALLED PHTOTLIMINESENT STRIP BY SERVICE DOOR IAW CRJ 550 AMM 11-30-03.

Source: SDR N6WA2024020801

2023

SMOKE/FUMES/ODORS/SPARKS · 2023-03-26 Matched by certificate designator
ATA 3040

Part: WINDSHIELD — SHORTED (LH) · airframe 32,317 hrs · 22,854 cycles

SMOKE FROM CA WINDSHIELD ELECTRICAL CONNECTORS NEXT TO PEN HOLDER IN FLIGHT AT 8000 FEET SMOKE STOPPED WHEN LH WSHLD HEAT SWITCHED OFF. PERFORMED OPS CHECK OF WINDSHIELD HEAT IAW CRJ 550 AMM 30-41-06. OPS CHECK FAILED. TROUBLESHOT LH WINDSHIELD HEAT IAW CRJ 550 FIM 30-41-00. FOUND NO ARCING. PERFORMED RESISTANCE CHECKS AND FOUND RESISTANCE ACROSS P1 AND P2 OUT OF LIMITS. R&R LEFT HAND WINDSHIELD IAW CRJ 550 AMM 56-11-01 OPS CHECK GOOD.

Source: SDR N6WA2023033001

2022

OTHER · 2022-05-23 Matched by certificate designator
ATA 5210

Part: DOOR — BINDING (ZONE 800) · airframe 31,434 hrs · 21,960 cycles

MAIN PAX DOOR HANDLE JAMMED CLOSED.PERFORMED OPS TEST OF MAIN CABIN DOOR IAW CRJ 550 AMM 52-11-00, OPS TEST GOOD AT THIS TIME

Source: SDR N6WA2022052501

2021

OTHER · 2021-09-08 Matched by certificate designator
ATA 5743

Part: RETAINER — CRACKED (RT MLG WW) · airframe 30,394 hrs · 20,991 cycles

ANGLE RETAINER IN R/H MLG WHEEL WELL HAS A CRACK.R&R ANGLE RETAINER IN R/H MLG WHEEL WELL IAW CRJ 700 AMM 53-83-85.

Source: SDR N6WA2021090801
OTHER · 2021-09-06 Matched by certificate designator
ATA 5240

Part: ATTACH ANGLE — CORRODED (SERVICE DOOR) · corrosion level 2 · airframe 30,394 hrs · 20,991 cycles

SERVICE DOOR, I/B ANGLE, ATTACH ANGLE CLIPS ARE CORRODED.

Source: SDR N6WA20210908701
OTHER · 2021-09-06 Matched by certificate designator
ATA 5320

Part: INTERCOSTAL — CORRODED (BS349-364 S27L-R) · corrosion level 2 · airframe 30,394 hrs · 20,991 cycles

INTERCOSTALS BETWEEN FS 349 AND 364, AT STR 27L AND 27R HAS CORROSION. R&R INTERCOSTALS BETWEEN FS 349 AND 364, AT STR 27L AND 27R IAW CRJ 700 SRM 51-42-06

Source: SDR N6WA2021090702
OTHER · 2021-09-06 Matched by certificate designator
ATA 5340

Part: BRACKET — CRACKED (BS 1144-1162 S7L) · airframe 30,394 hrs · 20,991 cycles

L/H WATER EJECTION BRACKET BETWEEN FS 1144 AND 1162 AT STR 7L IS CRACKED. EJECTION BRACKET BETWEEN FS 1144 AND 1162 AT STR 7L IAW CRJ SRM 51-42-21.

Source: SDR N6WA2021090703
OTHER · 2021-08-16 Matched by certificate designator
ATA 2562

Part: ELT — INOPERATIVE (CABIN) · airframe 30,394 hrs · 20,991 cycles

HAND HELD ELT FAILED OPS CHECK.R&R HAND HELD ELT IAW CRJ AMM 25-61-00, OPS CHECK GOOD.

Source: SDR N6WA2021081602

2020

WARNING INDICATION · 2020-07-06 Matched by certificate designator
ATA 5270

Part: WARNING MESSAGE — ACTIVATED (COCKPIT) · airframe 28,842 hrs · 19,616 cycles

LT EMERG DOOR CAUTION MSG. DEFERRED L EMERG DOOR CAUTION MSG ON OCN 70069502 PER MEL 52-70-03. CAT C AUTHORIZED BY MXC.

Source: SDR N6WA20200708602
FALSE WARNING · 2020-07-06 Matched by certificate designator
ATA 2613

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 28,842 hrs · 19,616 cycles

MLG OVERHEAT WARNING MSG. NO SIGNS OF OVERHEAT OR FIRE, DEFERRED MLG OVERHEAT DETECTION SYSTEM ON OCN 70069499 PER MEL 26-14-01B CAT B.

Source: SDR N6WA20200708601