N55FN

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
MEDWAY AIR AMBULANCE LLC (Y6WA)Operatoron 2018-12-15Operator named in NTSB report

Accident & incident history

Accident · 2018-12-15 Operator named in NTSB report
Learjet 35 No injuries Part 91MEDWAY AIR AMBULANCE LLC

Operated by Medway Air Ambulance (per NTSB report)

Source: NTSB case ERA19LA073

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

3 reports on file, 2007-08-16 – 2008-01-17.

WARNING INDICATION · 2008-01-17 Unresolved
ATA 2134

Part: PRESSURE SENSOR — MALFUNCTIONED (AFT BAGGAGE) · airframe 11,587 hrs · 9,655 cycles

LOSS OF CABIN PRESSURE AT 25K FT. PRESSURE SENSOR MALFUNCTIONED

Source: SDR 2008FA0000053
SMOKE/FUMES/ODORS/SPARKS · 2007-08-16 Unresolved
ATA 2497

Part: WIRE — BURNED (COCKPIT) · airframe 11,093 hrs · 9,338 cycles

ON DESCENT INTO HLN, SMOKE WAS NOTICED IN THE COCKPIT. THIS WAS PRECEDED BY AN AUG/AIL ANNUNCIATOR LIGHT ON THE GLARESHIELD. AN EMERGENCY WAS DECLARED, THE EMERGENCY CHECKLIST WAS ACCOMPLISHED, AND AN EMERGENCY LANDING WAS MADE. TWO COCKPIT CREW AND TWO MEDICAL TECHNICIANS WERE ONBOARD. IT WAS FOUND THAT A BURNED OUT WIRE BEHIND THE CIRCUIT BREAKER PANEL ON THE F/O SIDE WAS RESPONSIBLE. REPAIRS WERE MADE IAW COMPANY PROCEDURES AND THE A/C RETURNED TO SERVICE.

Source: SDR 2007F00047
SMOKE/FUMES/ODORS/SPARKS · 2007-08-16 Matched by certificate designator
ATA 2497

Part: WIRE — BURNED (COCKPIT) · airframe 11,093 hrs · 9,338 cycles

ON DESCENT INTO HLN, SMOKE WAS NOTICED IN THE COCKPIT. THIS WAS PRECEDED BY AN AUG/AIL ANNUNCIATOR LIGHT ON THE GLARESHIELD. AN EMERGENCY WAS DECLARED, THE EMERGENCY CHECKLIST WAS ACCOMPLISHED, AND AN EMERGENCY LANDING WAS MADE. TWO COCKPIT CREW AND TWO MEDICAL TECHNICIANS WERE ONBOARD. IT WAS FOUND THAT A BURNED OUT WIRE BEHIND THE CIRCUIT BREAKER PANEL ON THE F/O SIDE WAS RESPONSIBLE. REPAIRS WERE MADE IAW COMPANY PROCEDURES AND THE A/C RETURNED TO SERVICE.

Source: SDR 2007F00048