N566GJ

BOMBARDIER INC CL-600-2C11 · 2003 · Fixed-wing multi-engine · 2 engines · 55 seats · Valid Registration

Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2024-09-29 – 2026-10-09.

WARNING INDICATION · 2026-10-09 Matched by certificate designator
ATA 7931

Part: PRESSURE SWITCH — FAULTED (RT ENGINE) · airframe 45,404 hrs · 34,692 cycles

R ENG OIL PRESSURE WARNING MESSAGE IN FLIGHT (B1-007482 R OIL LO PRES SW / LO PRESS & ENG RUNNING). REMOVED AND R ENG OIL PRESSURE SWITCH IAW AMM 79-31-03/ 71-00-00, OPS CHKD GOOD, LEAK CHKD GOOD, ALL INDICATIONS NORMAL.

Source: SDR N6WA2026101502
OTHER · 2026-05-26 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 44,590 hrs · 33,927 cycles

EMERGENCY LIGHT AT ROW 8 OUT. REPLACED CEILING EMERGENCY FLOOD LIGHT IAW CRJ 550 AMM 33-51-09.

Source: SDR N6WA2026052603
WARNING INDICATION · 2025-11-26 Matched by certificate designator
ATA 3297

Part: ELEC CONNECTOR — LOOSE (NLG STEERING) · airframe 43,675 hrs · 33,066 cycles

NW STERRING INOP AND CAUTION IN FLIGHT. INSPECTED NOSE WHEEL STEERING AND FOUND ELECTRICAL CONNECTOR LOOSE AND T-BOLT CLAMP STUD BROKEN. RECONNECTED CONNECTOR AND REPLACED T-BOLT CLAMP IAW AMM 32-52-01. OPS CHECK GOOD.

Source: SDR N6WA2025112801
WARNING INDICATION · 2025-11-24 Matched by certificate designator
ATA 3251

Part: ACTUATOR — INOPERATIVE (NLG STEERING) · airframe 43,667 hrs · 33,060 cycles

STEERING INOPERATIVE IN FLIGHT. REMOVED AND REPLACED NLG STEERING ACTUATOR IAW AMM 32-51-10. OPS CHECKED GOOD.

Source: SDR N6WA2025112601
NO TEST · 2024-09-29 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 41,895 hrs · 31,345 cycles

EMERGENCY LIGHTS INOP. ALLOWED EMERGENCY LIGHTS TIME TO CHARGE IN ARMED POSITION AND PERFORMED OPS CHECKOF EMERGENCY LIGHTS IAW CRJ 550 AMM 33-51-00. OPSCHECK GOOD.

Source: SDR N6WA2024093001