N568NN
Registered owner: AMERICAN AIRLINES INC, TX (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
44 reports on file, 2015-07-14 – 2026-10-27.
Part: WARNING MESSAGE — FALSE ACTIVATION (ZONE 700) · airframe 26,553 hrs · 23,153 cycles
GEAR DISAGREE WARNING FOLLOWED BY QRH FIXED THE DISAGREE / PERFORMED TROUBLESHOOTING OF SELECTOR VALVE IAW FIM 32-51-50-810-801-A01. OPS CHECK GOOD. VERIFIED PROX SENSORS WITHIN RANGE WITH THE MDC IAW AMM 32-61-00-710-801-A01-PSA. COMPLETED 15 FULL EXTENSION/RETRACTIONS OF THE LANDING GEAR IAW AMM 32-30-00-865-801-A01, OPERATION NORMAL. NO EICAS MESSAGES. COULD NOT DUPLICATE FAULT. A/C OK FOR SERVICE. / NO PARTS REPLACED
Earlier reports · 2015–2025 · 43 reports
2025
Part: LIGHT — SPARKS (ZONE 200) · airframe 24,304 hrs · 21,403 cycles
CA SIDE READING LIGHT SPARKED AND SMOKED. / REMOVED AND REPLACED CA SIDE MAP READING LIGHT IAW AMM 33-13-03-000/400-801. OPS TEST GOOD.
Part: FMU — FAULTED (LEFT) · airframe 23,856 hrs · 21,054 cycles
L FADEC MSG IN FLIGHT. / REMOVED AND REPLACED R FADEC IAW AMM 73-21-01-000/400-801. REMOVED AND REPLACED LH ENGINE FMU IAW CRJ 900 AMM 73-21-03-000/400-801.OPS CHECK AND LEAK CHECK GOOD. PERFORMED HIGH POWER RUN IAW CRJ 900 AMM 71-00-00-866-806-A02-PSA. ALL PARAMETERS NORMAL. OCF SATISFACTORY.
2024
Part: ACTUATOR — UNSERVICEABLE (ZONE 600) · airframe 21,112 hrs · 18,826 cycles
FLAPS FAIL ON FINAL. FLAPS STUCK AT 45 / PERFORMED ELECTRICAL RIGGING OF RH FLAP IAW CRJ 900 AMM 27-52-00-820-802, RIGGING OUT OF TOLERANCES AND ADJUSTED. ON OPS CHECK OF FLAPS NOTED SQUEALING NOISE FROM FLAP PDU AND TORQUE TUBES ATTEMPTING TO GO FURTHER THAN FLAPS 45. REMOVED AND REPLACED PDU IAW CRJ 900 AMM 27-52-37-000-801 OPS TEST GOOD BUT FLAPS FAIL REMAINS AT FLAPS 45. B1 006551 SHOWS, CONTINUED TS WITH CRJ 900 FIM 27-52-09-810-802. FOUND RH TRIP INDICATORS TO BE TRIPPED, INBOARD ACTUATOR 2 RESET BUT OUTBOARD AT ACTUATOR 4 UNABLE TO RESET. REMOVED AND REPLACED FLAP ACTUATOR IAW CRJ900 AMM 27-52-09-000/400-804. OPS CHECK GOOD.
Part: SEAT TRACK — CORRODED (ZONE 200) · corrosion level 2
FWD CABIN RH I/B SEAT TRACKS P/N SH670-32159-1, BA690-31111-1 AND SH690-33407-1 HAVE CORROSION AROUND MULTIPLE ATTACH FASTENER LOCATIONS THAT ARE OUT OF SRM LIMITS. FS280.00-FS581 RBL 9.0
Part: SKIN PANEL — BURNED (BS 440 S3R) · airframe 20,512 hrs · 18,295 cycles
LIGHTNING STRIKE DAMAGE (SMALL HOLE IN SKIN PANEL) AT APPROXIMATELY FS 440.0 AND STGR 3R, CLASSIFIED IN MHIRJ REO 690-53-21-1744
Part: SKIN — SCRATCHED (BS 310 S25L) · airframe 20,512 hrs · 18,295 cycles
SCRATCH IN FUSELAGE SKIN AT APPROXIMATELY FS 310.0 AND STGR 25L. DAMAGE WITHIN SRM ALLOWABLE LIMITS PER 53-21-01-101-002-A04
Part: SKIN — GOUGED (BS 1031-1051) · airframe 20,512 hrs · 18,295 cycles
NUMEROUS NICKS, GOUGES AND DENTS ON FUSELAGE SKIN BETWEEN FS1031.00 - FS1051.30 AND STR22R - STR25R. DAMAGE CAUSED BY LP PNEUMATIC DUCT PLUG TETHERED BY LANYARD COMING LOOSE IN FLIGHT AND IMPACTING AGAINST THE FUSELAGE REPEATEDLY. CLASSIFIED AND REPAIRED IAW MHIRJ REO 690-53-61-1352.
Part: SEAT TRACK — CORRODED (ZONE 200) · corrosion level 2 · airframe 20,512 hrs · 18,295 cycles
FWD CABIN RH I/B SEAT TRACK P/N BA690-31111-1 AND HAS CORROSION AROUND MULTIPLE ATTACH FASTENER LOCATIONS THAT ARE OUT OF SRM LIMITS. FS280.00-FS581 RBL 9.0
Part: SKIN — GOUGED (FWD CARGO DOOR) · airframe 20,512 hrs · 18,295 cycles
FWD CARGO DOOR HAS GOUGES AT THE DOOR SKIN EDGE COMMON TO THE LOWER FORWARD AND AFT CORNERS WITHIN SRM REPAIR LIMITS.
Part: FITTING — GOUGED (LT WING TE) · airframe 20,512 hrs · 18,295 cycles
GOUGE DAMAGE TO LH WING TRAILING EDGE MACHINED FITTINGS AT WS199.40, WS202.67 AND WS231.23) CAUSED BY INCORRECT HARDWARE ORIENTATION. DAMAGE CLASSIFIED AND REPAIRED IAW MHIRJ REO 690-57-51-332 REV --.
Part: SEAT TRACK — CORRODED (ZONE 200) · corrosion level 2 · airframe 20,512 hrs · 18,295 cycles
FWD CABIN RH I/B SEAT TRACK P/N SH690-33407-1 HAS CORROSION AROUND MULTIPLE ATTACH FASTENER LOCATIONS THAT ARE OUT OF SRM LIMITS. FS280.00-FS581 RBL 9.0
Part: SHELF — CRACKED (ZONE 200) · airframe 20,512 hrs · 18,295 cycles
SHELF THAT SECURES JB-6 HAS A CRACK IN THE FORWARD RH OUTBOARD CORNER APPROX. 1/4 INCH IN LENGTH
Part: BEARING — WORN (RUDDER HINGE) · airframe 20,512 hrs · 18,295 cycles
RUDDER FAILS BACKLASH CHECK FOR HYDRAULIC SYSTEM 1 & 2 PER CRJ 900 AMM TASK 27-21-00-720-803. MAXIMUM ALLOWABLE BACKLASH ON HYDRAULIC SYSTEM 1 IS 0.250". HIGHEST TESTED VALUE WAS 0.395". MAX ALLOWABLE BEARING BACKLASH VALUE IS 0.120", MEASURED VALUE WAS 0.132". MAXIMUM ALLOWABLE BACKLASH ON HYDRAULIC SYSTEM 2 IS 0.250", AND HIGHEST TESTED VALUE WAS 0.365". WORN SPHERICAL BEARINGS IN HINGE FITTINGS 2 AND 3 IS THE CAUSE.
Part: BEARING — WORN (RUDDER HINGE) · airframe 20,512 hrs · 18,295 cycles
RUDDER FAILS BACKLASH CHECK FOR HYDRAULIC SYSTEM 1 & 2 PER CRJ 900 AMM TASK 27-21-00-720-803. MAXIMUM ALLOWABLE BACKLASH ON HYDRAULIC SYSTEM 1 IS 0.250". HIGHEST TESTED VALUE WAS 0.395". MAX ALLOWABLE BEARING BACKLASH VALUE IS 0.120", MEASURED VALUE WAS 0.132". MAXIMUM ALLOWABLE BACKLASH ON HYDRAULIC SYSTEM 2 IS 0.250", AND HIGHEST TESTED VALUE WAS 0.365". WORN SPHERICAL BEARINGS IN HINGE FITTINGS 2 AND 3 IS THE CAUSE.
Part: FAIRING — UNSERVICEABLE (FAN COWL HINGE) · airframe 20,512 hrs · 18,295 cycles
RH ENGINE, FWD FAN COWL HINGE LINE FAIRING DAMAGED/BENT BEYOND REPAIR LIMITS. (PANEL 442BB)
Part: COWLING — DENTED (RT NACELLE) · airframe 20,512 hrs · 18,295 cycles
RH NACELLE, I/B SIDE, FAN COWL PANEL (442AB), TOP EDGE OF PANEL DAMAGED (2 DENTS) APPROX. 12" FROM AFT END OF PANEL. DAMAGE CLASSIFIED IN PSA AIRLINES EA A1-690-54-00024 REV A.
Part: BRACKET — CRACKED (SERVICE DOOR) · airframe 20,512 hrs · 18,295 cycles
SERVICE DOOR STABILIZATION BRACKET (P/N CC670-38380-3), CRACKED (UPPER STABILIZER BAR MOUNT AT ROD ATTACH POINT)
Part: BUSHING — WORN (LT ELEVATOR) · airframe 20,512 hrs · 18,295 cycles
LH ELEVATOR FAILS BACKLASH CHECK FOR HYDRAULIC SYSTEM 3 PER CRJ900 AMM CH. 27-31-00-720-804. MAXIMUM ALLOWABLE BACKLASH IS 0.070", MEASURED VALUE WAS .090". SPHERICAL BALL P3A3211, AND BUSHING B0309008-08-055 AT LH ELEVATOR, PCU #3 WORN BEYOND LIMITS.
Part: BEARING — WORN (LT ELEVATOR) · airframe 20,512 hrs · 18,295 cycles
LH ELEVATOR FAILS BACKLASH CHECK FOR HYDRAULIC SYSTEM 3 PER CRJ900 AMM CH. 27-31-00-720-804. MAXIMUM ALLOWABLE BACKLASH IS 0.070", MEASURED VALUE WAS .090". SPHERICAL BALL P3A3211, AND BUSHING B0309008-08-055 AT LH ELEVATOR, PCU #3 WORN BEYOND LIMITS.
Part: DRAIN — CORRODED (FWD GALLEY) · corrosion level 2 · airframe 20,512 hrs · 18,295 cycles
RH FWD GALLEY SERVICE DOOR AFT DRAIN TUBE ASSEMBLY CORRODED THROUGH.
Part: CHANNEL — CRACKED (WNG-BDY FAIRING) · airframe 20,512 hrs · 18,295 cycles
WING/FUSELAGE FAIRING, RH (PANEL 196DR) SUPPORT CHANNEL HAS A 1.33" CRACK, 7.4" FROM FWD END OF CHANNEL. PN:BA690-39311-1.
Part: MOUNT FITTING — CORRODED (GALLEY) · corrosion level 2 · airframe 20,512 hrs · 18,295 cycles
G1 GALLEY HAS 2 CORRODED FLOOR FITTING MOUNTS. FWD OUTBD AND AFT INBD LOCATIONS.
Part: MOUNT FITTING — UNSERVICEABLE (FWD LAVATORY) · airframe 20,512 hrs · 18,295 cycles
FWD LAVATORY FWD OUTBOARD FLOOR MOUNT EXFOLIATING CORROSION THROUGH MOUNT.
2023
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 20,046 hrs · 17,885 cycles
DIRTY SOCK SMELL COMING THRU VENTILATION SYSTEM / PERFORMED POST WASH BLEED DRY OUT PROCEDURE ON L & R BLEEDS IAW CRJ-900 AMM 72-00-00-100-803-A01-PSA STEPS H(6) THROUGH SHUTDOWN. NO ABNORMAL ODORS NOTED AFTER EXTENDED VERIFICATION STEP.
2022
Part: PRESSURE VALVE — DEPARTED · airframe 16,423 hrs · 14,787 cycles
THE LOW PRESSURE DOOR WAS LEFT OPEN DEPARTING CLT AND THE LOW PRESSURE VALVE DOOR CAME OFF SOMEWHERE BETWEEN CLT AIRPORT AND JAN AIRPORT. CLT OPS HAS BEEN NOTIFIED OF THE MISSING VALVE COVER AND AIRCRAFT DAMAGE AS WELL. A DENT NEXT TO THE LOW PRESSURE VALVE DOOR AND SOME SCRATCHES WERE DOCUMENTED BY OUTSTATION MAINTENANCE IN JAN. THE AIRCRAFT LANDED WITHOUT INCIDENT IN JAN. NO FURTHER INFORMATION HAS BEEN PROVIDED. LP DOOR LEFT OPENED AND CONNECTION CAP FELL OFF. INSPECTED LP DOOR IAW CRJ 900 AMM 52-45-00-PSA. FOUND LP DOOR LANYARD AND CAP MISSING. COMPLIED WITH REO 690-53-61-1080. DENT L=1.3960" W=0.9580" D=0.25" BETWEEN FS 1031.00 AND FS1051.30 AND STGR 24R AND STGR 25R.
2020
Part: FAN — FAILED (RECIRCULATION) · airframe 13,023 hrs · 11,844 cycles
RECIRC FAN FAULT STATUS MESSAGE FOLLOWED BY BURNING RUBBER SMELL. TROUBLE SHOT RECIRC FAN FAULT STATUS MESSAGE "RECIRC FAN 2, FAILED WIRING/LOW FAN SPEED" IAW CRJ 900 FIM 21-22-10-810-802-A02. REMOVED AND REPLACED RT RECIRC FAN IAW CRJ 900 AMM 21-22-10-000/400-801-A01. OPS CHECK GOOD.
Part: FLOOR SUPPORT — CORRODED (BS 310-349) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
INTERCOSTALS BELOW FLOOR AT PAX DOOR FROM FS 310.00 TO FS 349.00 ARE CORRODED. REPLACED INTERCOSTALS.
Part: INTERCOSTAL — CORRODED (BS 349-364) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
L/H AND R/H INTERCOSTALS AT STGR 27 BETWEEN FS 349 AND FS 364 ARE CORRODED. REPLACED INTERCOSTALS.
Part: SEAT TRACK — CORRODED (BS 485-533) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
FLOOR SEAT TRACK CORRODED AT RBL 9.00 BETWEEN FS 485 AND FS 533.00.
Part: FLOORBEAM — CORRODED (BS 280) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
FS 280 CROSSBEAM FWD FLOOR SUPPORT ANGLE BETWEEN LBL 12 AND RBL 12 IS CORRODED.
Part: SEAT TRACK — CORRODED (BS 364-485) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
FLOOR SEAT TRACK CORRODED AT LBL 27.00 AND BETWEEN FS 364 TO FS 485.00.
Part: INTERCOSTAL — CORRODED · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
INTERCOSTALS CORRDED.
Part: SEAT TRACK — CORRODED (BS 364-483) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
FLOOR SEAT TRACK CORRODED AT RBL 9.00 AND BETWEEN FS 364 TO FS 483.00. REPLACED SEAT TRACK.
Part: SEAT TRACK — CORRODED (BS 374-483) · corrosion level 2 · airframe 12,603 hrs · 11,451 cycles
FLOOR SEAT TRACK AT LBL 9.00 AND BETWEEN FS 374.00 TO FS 483 CORRODED IN SEVERAL LOCATIONS. SEAT TRACK REPLACED.
2019
Part: ACM — FAILED (RIGHT) · airframe 11,440 hrs · 10,492 cycles
SMOKE IN CABIN. C/W GVI OF AFT EQUIPMENT BAY IAW CRJ 900 AMM 53-60-01-PSA. NO VISUAL DEFECTS NOTED. T/S PER CRJ 900 FIM 21-22-00-810-806 AND FOUND ISSUE TO BE WITH THE RH PACK. MAINTENANCE REMOVED AND REPLACED R/H AIR CYCLE MACHINE OPS CHECK GOOD AT THIS TIME
Part: PROXIMITY SENSOR — OUT OF ADJUST (LANDING GEAR) · airframe 10,811 hrs · 9,878 cycles
IN PREPARATION TO LAND THE CREW RECEIVED A ANTI SKID CAUTION MESSAGE WITH A WOW MESSAGE. THE CREW RAN THE QRH AND WAS NOT ABLE TO RESET THE SYSTEM. THEY DECLARED AN EMERGENCY AND GROUND EMERGENCY EQUIPMENT RESPONDED. THE AIRCRAFT LANDED WITHOUT ISSUE AND WAS ABLE TO TAXI TO THE GATE. NO PASSENGERS ON BOARD DUE TO PREVIOUS DELAYS IN SAV. ADJUSTED PROX SENSOR PX113PX03 IAW AMM. OPS CHECK GOOD AT THIS TIME / "
2018
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 8,731 hrs · 8,067 cycles
AIRCRAFT FAILED TO PRESSURIZE ON CLIMBOUT AND HAD SERVICE DOOR CAUTION LIGHT, THE CREW DECLARED AN EMERGENCY AND RETURNED TO FIELD. THE / MASKS DID NOT DROP, BUT EQUIPMENT DID ROLL. THE AIRCRAFT TAXIED INTO THE GATE UNDER ITS OWN POWER. MX INSPECTED A/C AND FOUND MDC FLAGGING PX38 SENSOR FAR. INSPECTED SERVICE DOOR AND SEAL. FOUND NO DEFECTS. PRESSURE CHECK GOOD.
Part: UNKNOWN — ODOR (CABIN) · airframe 7,494 hrs · 6,942 cycles
AFTER PUSHING OFF THE GATE FAS REPORTED AN ODOR IN THE CABIN, LIKE A BURNING MATCH. RETURNED TO THE GATE. MAINTENANCE INSPECTED. FOUND NO EVIDENCE OF SOURCE OF BURNING ODOR. RAN ENGINES, NO ODOR NOTED.
2017
Part: LENS — MISSING (EMERGENCY LIGHT) · airframe 4,926 hrs · 4,512 cycles
SERVICE DOOR EXIT SIGN LENS IS MISSING. INSTALLED A REPLACEMENT LENS.
2016
Part: COVER — MISSING (EMERGENCY LIGHT) · airframe 3,604 hrs · 3,273 cycles
GALLEY FLOOR EMERGENCY LIGHT COVER MISSING. MAINTENANCE INSTALLED LENS COVER AND PERFORMED CHECKS IAW THE AMM. THE AIRCRAFT WAS RELEASED FOR SERVICE.
Part: CIRCUIT BREAKER — POPPED (EMERGENCY LIGHTS) · airframe 3,353 hrs · 3,048 cycles
EMERGENCY LIGHTS ON WITH SWITCH IN ARM POSITION. CREW RESET CIRCUIT BREAKER CBP-2 U3 AND THE ACFT CONTINUED SERVICE.
2015
Part: FAN — ODOR (CABIN) · airframe 1,565 hrs · 1,430 cycles
SHORTLY AFTER TAKEOFF, CREW REPORTED SMOKE ODOR WHICH PROGRESSIVELY GOT WORSE DURING CLIMBOUT TO 1,000 FT. CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. TROUBLESHOT, AND FOUND ODOR COMING FROM FORWARD GALLEY EXHAUST FAN.
Part: PROBE — FAILED (BRAKE TEMP) · airframe 887 hrs · 823 cycles
CREW REPORTED BRAKE OVERHEAT MESSAGE IN CRUISE AND ON APPROACH. INNER LT BRAKE TEMPERATURE MONITORING SYS, BTMS, INDICATOR WENT TO 20 BOTH TIMES. CREW LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED, R & R NR 2 MLG BRAKE TEMPERATURE PROBE AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.