Maintenance disclosures
4L DOOR SLIDE LIGHT WON'T ILLUMINATE WITH DOOR ARMED. FOUND GIRT BAR BRACKET UNSECURED. RESECURED IN BRACKET. OPS TEST IAW AMM 52-11. OPS CHECKED GOOD. (9083156) AIRCRAFT WAS GROUNDED.
KNUCKLE BUSTER ON DOOR 1L EXTENDS A LOT. RETRACTABLE DOOR MECHANISM (KNUCKLE BUSTER ) ON DOOR 1L WAS ADJUSTED IAW AMM 52-11-20. (1657830) AIRCRAFT WAS GROUNDED
ON FINAL ARMED/DISARMED LEVER MOVES DURING OPEN L4 DOOR. ADJUST LINKAGE TO GIRT BAR MECHANISM AT L4 DOOR WAS PERFORMED IAW AMM 52-11-20 AND ARMED/DISARMED LEVER DOES NOT MOVES DURING DOOR OPENING, TESTED OK.
IAW AMDS 2040-8008: DURING RESERVOIR POWER PINS REMOVAL, LOW PRESSURE (2,100 PSI) WAS FOUND AT 2R DOOR POWER EMERGENCY RESERVOIR. EMERGENCY POWER RESERVOIR OF DOOR 2RH WAS REPLACED IAW AMM 52-11-30. (1654468) AIRCRAFT WAS GROUNDED
FUSELAGE SKIN, BS 1540 & 1560, STR 27R & 29R. AFT LAVATORY SERVICE CUTOUT CORROSION. IAW ERA 634692-14. (1655469) AIRCRAFT WAS GROUNDED.
LIGHTING STRIKE NEAR T/E ON TIP WINGLET AT RT WING. T/E ON TIP WINGLET AT RH WING WAS REPAIRED PER PRI 634986-14 REV 2 AND ERA 634986-14 REV ORIGINAL. (1651963) AIRCRAFT WAS GROUNDED
IN REF TO AMDS 2525-0062: WHILE ACCOMPLISHING CIC APPLICATION, CRACK WAS FOUND ON LT OTBD SEAT TRACK BS 550 AT FLOOR PAX CABIN STRUCTURE. LT OTBD SEAT TRACK BS 550 AT FLOOR PAX CABIN STRUCTURE WAS REPAIRED IAW SRM 53-00-52-2R PROCEDURE 3 REPAIR 3. (1652296) AIRCRAFT WAS GROUNDED
SHIP 5807 N REF TO AMDS 2525-0062: WHILE ACCOMPLISHING CIC APPLICATION, CRACK WAS FOUND ON LH OUTBD SEAT TRACK BS 550 AT FLOOR PAX CABIN STRUCTURE. LT OTBD SEAT TRACK BS 550 AT FLOOR PAX CABIN STRUCTURE WAS REPAIRED IAW SRM 53-00-52-2R. (1652305) AIRCRAFT WAS GROUNDED.
AFTER REMOVAL OF AFT TOILET SERVICE PANEL CORROSION WAS FOUND AROUND FUSELAGE SKIN BS 1540-1560 S-29R TO S-27R AT LOWER FUSELAGE. FUSELAGE SKIN STA 1540- 1560 S-29R TO S-27R AT LOWER FUSELAGE WAS REPAIRED PER ERA 634606-14 REV. ORIGINAL, SECTION I: REPAIR INSTRUCTIONS AND PRI 634606-14 REV. 0 TO REV 5. (1648948) AIRCRAFT WAS GROUNDED
CORROSION ON LT SIDEPLATE (UPPER/LOWER) STA 1490-1460 AT AFT CARGO COMPARTMENT. SIDEPLATE LH SIDE STA 1380+10 TO 1520+10 AT AFT CARGO COMPARTMENT WERE REPLACED PER B757-300 SRM 51-40-02-0G. (1648185) AIRCRAFT WAS GROUNDED
ENGAGEMENT FOR THE GIRT BAR AFT SLIDER IS LESS THAN 0.37 INCH AT L4 DOOR. L4 DOOR SLIDE GIRT BAR WAS REPLACED PER AMDS 2561-01257-01E STEP 16. AND AIPC 25-66-05. (1638499) AIRCRAFT WAS GROUNDED
ENGAGEMENT FOR THE GIRT BAR AFT SLIDER IS LESS THAN 0.37 INCH AT R4 DOOR. R4 DOOR SLIDE GIRT BAR WAS REPLACED PER AMDS 2561-01257-01F STEP 16. AND B757-300 AIPC 25-66-05-05 ITEM -112W. (1638350) AIRCRAFT WAS GROUNDED
AFTER REMOVAL OF AFT TOILET SERVICE PANEL CORROSION WAS FOUND ON INTERCOSTAL OF SERVICE PANEL. CORROSION LEVEL 2: INTERCOSTAL (PAN ASSY) OF AFT SERVICE TOILET PANEL WAS REPLACED PER SRM 51-40- 02-0G PAR 4.B. (1636269) AIRCRAFT WAS GROUNDED.
CORROSION OUT OF LIMITS IN REF NRC 00459: UT) MEASUREMENT THICKNESS WAS ACOMPLISHED ON ANGLE FLOOR SUPPORT STA 976 TO 1040 STGR 17L OF AREA ABOVE WING CENTER SECTION ORIGINAL THICKNESS 0.070IN AND MINIMUM REMAINING THICKNESS IS 0.033IN THEREFORE IT IS OUT OF LIMITS PER B757-300 SRM 53-40-13-1A PROCEDURE 1, DETAIL VII. CORROSION LEVEL 2: ANGLE FLOOR SUPPORT STA 976 TO 1040 STGR 17L OF AREA ABOVE WING CENTER WAS REPLACED PER B757-300 SRM 51-40-02-0G (1636264) AIRCRAFT WAS GROUNDED
CORROSION LEVEL 2 IN FRAME STA 1440 BTW S-30 TO S-29R AND BWT S-29L TO S-28L AT AFT CARGO COMPARTMENT. FRAME STA 1440 BTW S-30 TO S-29R AND BWT S-29L TO S-28L AT AFT CARGO COMPARTMENT WAS REPLACED PER B757-300 SRM 51-40-02-0G PAR. 4, B AND PAR. 7, D. (LP 1634705 - AIRCRAFT WAS GROUNDED)
CRACK ON STABILIZATION STRAP STA 1621 LBL 44, STA 1380 RBL 46 AT CEILING AFT CARGO COMPARMENT. REPAIRED PER SRM 53-00-51-2R PROCEDURE 12, REPAIR 12. (LP 1628830 - AIRCRAFT WAS GROUNDED)
CRACK ON STABILIZATION STRAPS 2EAS FROM STA 365.-25 TO STA 377.7 1EA LBL 25 AND 1EA LBL 46 AT CABIN PASSENGER FLOOR. CABIN PASSENGER FLOOR WAS REPAIRED PER B757-300 SRM 53-00-51-2R PROCEDURE 12 REPAIR 12. (LP 1625322 - AIRCRAFT WAS GROUNDED)
CORROSION LEVEL 2 ON INBD AND OUTBD RH SEAT TRACK FROM STA 365.25 TO 418 AT PASSENGER CABIN FLOOR. REPLACED PASSENGER CABIN FLOOR PER B757-300 SRM 51-40-02-0G. (LP 1624837 - AIRCRAFT WAS GROUNDED)
CRACK ON STABILIZER STRAP AT BS 560 LBL 45 AT FWD CARGO COMPARTMENT. STABILIZER STRAP AT STA 560 LBL 45 AT FWD CARGO COMPARTMENT WAS REPAIRED PER B757-300 SRM 53-00-51-2R-12 REPAIR INSTRUCTIONS. (1621690) AIRCRAFT WAS GROUNDED
CORROSION ON CHANNEL 30 STA 1620 AT AFT CARGO COMPARTMENT. S CORROSION LEVEL 2. CHANNEL 30 STA 1620 AT AFT CARGO COMPARTMENT WAS REPLACED PER B757-300 SRM 51-40-02-0G PARAGRAPH 4.BAND PARAGRAPH 7.D. (1621688) AIRCRAFT WAS GROUNDED
CORROSION ON BOXBEAM FROM STA 1660 TO STA 1680 RBL 54 AT PASSENGER CABIN FLOOR. CORROSION LEVEL 2. BOXBEAM FROM STA 1660 TO STA 1680 RBL 54 AT PASSENGER CABIN FLOOR WAS REPLACED PER B757-300 SRM 51-40-02-0G PAR 7 D. (1617683) AIRCRAFT WAS GROUNDED
AIRCRAFT 5807, EMERGENCY LIGHT L EMERG CHARGER C/B POPPED WHEN ARMED. CORRECTIVE ACTION: REPLACED POWER SUPPLY CHARGER M371. CKS OK PER B757-300 AMM 33-51. (LP 8048982)
L1 DOOR ASSIST BOTTLE BELOW SERVICE CHECK LIMITS. R & R L1 EMERGENCY POWER RESERVOIR IAW AMM 52-11-30. (8138794)
PAX AND CREW REPORTS STRONG MIX OF ODORS ON TAXI RTG PER CA/ DSPCH 3 DOOR BACK. REF LOG 8138772 FOR BOROSCOPE FINDINGS. WORK CARD 0550-9001-B757, C/W REF ERA 631308-14 FOR REPAIR. (8138770)
R1 DOOR WILL NOT ARM. FOUND GREEN CORD WITH CLIP FROM SLIDE OUT OF IT'S POCKET. STOWED SAME. REINSTALLED BUSSEL COVER. SLIDE ARMING OPS NORMAL . REF B757 AMM 52-11. (6683456)
EXIT SIGN FELL OFF DURING TAKE OFF. REASECURED SIGN COVER PER B757 AMM 33-51 OPS CHECK NML. (1287137)
R1 ENTRY DOOR WILL NOT ARM. FOUND 1R ESCAPE SLIDE MOORING LINE STICKING OUT. RESECURED ESCAPE SLIDE MOORING LINE. REF B757 AMM25-66. (7189244)
SHIP 5807 EMERGENCY EXIT SIGN FELL OFF IN MID A/C. CORRECTIVE ACTION: RESECURED EMERGENCY EXIT LENSE COVER. (7026496)
SHIP 5807 DENT ON FUSELAGE SKIN PANEL BTW STA 760 AND 780 AND BTW S-15L AND S-16L. CORRECTIVE ACTION: SUMMARY OF NRC 00052: FUSELAGE SKIN BTW STA 760 AND 780 AND BTW S-15L AND S-16L WAS REPAIRED PER ER/A 625264-14 REV ORIGINAL SECTION I: REPAIR INSTRUCTIONS AND PRI 625264-14 REV 4. (0895403)
SHIP 5807 DTA MONITOR INSPECTION LOG REF ERA 625264-14 FUSELAGE / SKIN BTW STA 760 AND 780 AND BTW S-15L AND S-16L / DENT. CORRECTIVE ACTION: REF ERA 625264-14. (0895249)
SHIP 5807 CRACK ON STABILIZATION STRAP STA 396.5 BL=0 AT E/E COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00079: STABILIZATION STRAP STA 396.5 BL=0 AT E/E COMPARTMENT WAS REPAIRED PER B757-300 SRM 53-00-51-2R PROCEDURE 13 REPAIR 13. (0884393)
SHIP 5807 CRACK ON STABILIZER STRAP BTW STA 365 AND STA 377 AND LBL 20 AT E/E COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00091 PERMANENT REPAIR CATEGORY "A" ON STABILIZER STRAP BTW STA 365 AND STA 377 AND LBL 20 AT E/E COMPARTMENT WAS PERFORMED PER B757-300 SRM 53-00-51-2R, PROCEDURE 12, REPAIR 12. (0881672)
SHIP 5807 CRACK ON FIXED LEADING EDGE OSS 421 AT RH WING. CORRECTIVE ACTION: SUMMARY OF NRC 00062: FIXED LEADING EDGE OSS 421 AT RH WING WAS REPAIRED PER B757-300 SRM 51-70-17-0G IN REFERENCE B757-300 SRM 57-41-01-2R PROCEDURE 1 REPAIR 1 TABLE I. (0879364)
SHIP 5807 IN REFERENCE AD, A.A WORK CARD 2561-01257-01F STEP12 AND 14 OUT OF LIMITS BTW GIRT BAR SLIDER AND FWD AND AFT FLOOR FITTINGS AT 4R PASSENGER DOOR. CORRECTIVE ACTION: SUMMARY OF NRC 00022: GIRT BAR AT 4R DOOR P/N: UNK WAS REPLACED BY SERVICEBLE GIRT BAR P/N: 140N2762-26 TEST OF MEASURE MINIMUM ENGAGEMENT WAS PERFORMED UNDER AD, A.A, 2561- 01257-01F STEP 10 TO STEP 14. AND APLICABILITY WAS VERIFY PER B757-300 IPC 25-66-05-05 ITEM -112W, TEST OK
SHIP 5807 4L DOOR SLIDE/BUSTLE HAS ROPE HANGING FROM DOOR. CORRECTIVE ACTION: RESTOWED ROPE, SECURITY CHECK GOOD. (6580656)
SHIP 5807 4R KNUCKLE KNOCKER DOES NOT MOVE OUT WHEN DOOR IS ARMED. CORRECTIVE ACTION: KNUCKLE KNOCKER AT DOOR 4R STILL INTERFERING WITH CORNER OF DOOR LINER CUTOUT SLIGHTLY - DOES NOT AFFECT ARMING - TRIMMED KNUCKLE KNOCKER OPENING A LITTLE MORE NOW POPS OUT WITH DOOR ARMING CONSISTENTLY. (6580622)
SHIP 5807 4R DOOR DIFFICULT TO ARM. CORRECTIVE ACTION: REPOSITIONED DOOR TRIM NEAR KNOCKER. DOOR ARMING OPS GOOD PER B757 AMM 25-64. (6580614)
SHIP 5807 R FWD WINDOW BEGAN ARCING AT LOWER CORNER. APPLIED QRH TURNED R FWD WINDOW HEAT OFF. WINDOW INTACT BUT LOWER CORNER OUTER PANE BURNED. WINDOW FOUND TO BE CRACKED AFTER PARKING. CORRECTIVE ACTION: R/R RIGHT # 1 WINDSHIELD REF B757 AMM 56-11. OPN GOOD.
SHIP 6807 EMERGENCY EXIT LIGHT AT 27A DAMAGED/LENS MISSING. CORRECTIVE ACTION: REMOVED AND REPLACED EMERGENCY EXIT LIGHT AT SEAT 27A PER B757 AMM 33-51. OPS CHECK GOOD. (5411181)
SHIP 5807 FA NABLE TO ARM DOOR 4L. CORRECTIVE ACTION: LANYARD FOR SLIDE RESTOWED OP'S CHECK GOOD. REF 757 AMM 25-66-00. (5411154)
KNUCKLE KNOCKER ON 4R DOOR WILL NOT GO TO ARMED POSITION WHEN DOOR CLOSED. FOUND DOOR LINER NOT ALIGNED IN GROOVE OF SLIDE BUSTLE. READJUSTED TOP DOOR LINER. OPS NORMAL
SHIP 5807 EMERGENCY EXIT SIGN COVER LOOSE / DETATCHED LOCATIONS:605. CORRECTIVE ACTION: SECURED EMER EXIT SIGN. (0696785)
SHIP 5807 RT OVERWING TEST 2 BTL PRESS LIGHT NOT ILLUMINATING. CORRECTIVE ACTION: T/S PER B757 WDM 25-65-21. FOUND BROKEN WIRE W6484-0014-24 BEHIND SIDEWALL KICK PANEL. REPAIRED WIRE PER B757 SWPM 20-10-13 . R WING SLIDE BOTTLE PRESSURE INDICATION OPS CK GOOD PER B757 AMM 25-65-00. (6413508)
SHIP 5807 FWD FITTING ON DOOR 4R LOOSE. CORRECTIVE ACTION: REMOVED AND REPLACED DOOR 4R FITTING AND RIGGED AS NEEDED REF AMM 52-11 OPS CHECKED NORMAL. (6467263)
SHIP 5807 DOOR 4 RT EMERGENCY SLIDE PACK FELL TO THE GROUND WHILE OPENING THE DOOR PACK NOT DEPLOYED PINNED AND SAFETIED THE PACK. CORRECTIVE ACTION: REMOVED AND REPLACED DOOR 4 R EMER SLIDE PACK WITH SERVICEABLE PER AMDS CARD. (6467262)
SHIP 5807 FUSELAGE SKIN DENTS AT STA 610, S-17L, REPAIR. ER/A 500142-14AD. CORRECTIVE ACTION: REF ERA 500142-14AD. (0586612)
R1 DOOR ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT INOPERATIVE. R & R SLIDE LIGHT ASSY AS PER B757 AMM 33-11. OPS NORMAL.
SHIP 5807 R4 DOOR ARMED KNUCKLE KNOCKER WILL NOT DEPLOY. CORRECTIVE ACTION: READJUSTED R4 DOOR BUSTLE PER B757 AMM 52-11. OPS CHK GOOD. (4869253)
SHIP 5807 STBY INVERTER STATUS MSG IN FLIGHT. CORRECTIVE ACTION: REMOVED & REPLACED STBY INVERTER REF B757 AMM 24-33. CHK OK. (5311006)
SHIP 5807 -DIV- TO DTW DUE TO ANTISKID MESSAGE AND WEATHER CONDITIONS IN MSP. CORRECTIVE ACTION: R/R RELAY K419 AND PARKING BRAKE SW 459 AND PERFORMED ADJUSTMENT OF PARKING BRAKE. PERFORMED A/S TRANSDUCER SPIN UP TEST, CKS GOOD.
SHIP 5807 -MISC/DE- DUE TO ANTISKID MESSAGE. CORRECTIVE ACTION: REPLACED PARKING BRAKE VALVE.
SHIP 5807 DURING CRUISE AT FL 380, FLIGHT ATTENDANTS REPORTED ELECTRICAL ODOR IN AFT HALF OF CABIN. ALSO REPORTED IFE CONTROL BOX HOT TO TOUCH. AFTER SHUTTING DOWN IFE, ODOR DISSIPATED. PERFORMED SYSTEM QUICK TEST AND ALL TEST, NO PROBLEMS NOTED. FOUND SPM AT 17B ENCASED IN SHREDDED AND MELTED PLASTIC BAG. VACUUMED OUT CAVITY AND R&R SPM. SYSTEM OPS CHECK NORMAL. REPLACED SPM IAW B757 AMM 23-32. COMPLIED WITH B757 NO GO ODI PREVENTION 2172 SMOKE IN CABIN.
SHIP 5807 CREW NOTED 1R DOOR HARD TO ARM. CORRECTIVE ACTION: FOUND SURVIVAL KIT LANYARD TANGLED AROUND GIRT BAR. TANGLE RMVD AND STOWED LANYARD FROM GIRT BAR. 1R DOOR ARMING OPN GOOD. REF B757 AMM 25-66. (5485966)
SHIP 5807 EMERGENCY EXIT COVER DIFFUSER LENS DAMAGED OR MISSING / LOCATIONS:603. CORRECTIVE ACTION: REINSTALLED AS REQUIRED. (0134421)
SHIP 5807 UPON CLOSING R1 DOOR FOR DEPARTURE LATCHES WILL NOT CLOSE AND ARM COMPLETELY. CORRECTIVE ACTION: PERFORMED OPS CHECK OF 1R DOOR SLIDE PER B757 AMM 52-11. OPS CHECKS GOOD. REMOVED DEBRIS OK FOR SERVICE. (5485950)
SHIP 5807 R1 DOOR WILL NOT ARM. CORRECTIVE ACTION: REMOVED DEBRI FROM GIRT BAR TRACK. CYCLED DOOR SEVERAL TIMES PER B757 AMM 52-11. OPS CHECK GOOD. A/C OK FOR SERVICE. (5485900)
SHIP 5807 1R DOOR IS NOT ARMING PROPERLY PER FLIGHT ATTENDANT. CORRECTIVE ACTION: LUBRICATED & OPS TESTED GIRT BAR ENGAGEMENT PER B757 AMM 52-12. OPS CKS GOOD. (9635790)
SHIP 5807 M737 BATTERY INOP. CORRECTIVE ACTION: REMOVED AND REPLACED M737 BATTERY PER B737 AMM 33-51-07. (4461901)
SHIP 5807 - ATB/FUME - DUE TO REPORTS OF AIR NOISE, VIBRATION AND SMELL IN AFT CABIN. CORRECTIVE ACTION: T/S FOUND RT RECIRC AIR CHECK VALVE ORIENTED SIDEWAYS, REINSTALLED. REMOVED AND REPLACED LEFT AND RIGHT RECIRC AIR FILTERS. FOUND APU DUCT SUPPORT BRACKETS BROKEN IN AFT CARGO BIN, REPLACED BRACKETS.
SHIP 5807 FROM THE FLOOR AND CEILING TOWARDS THE AFT GALLEY. THEY SMELLED A BRIEF RUBBER, METALLIC SMELL. IT WAS CONSTANT VIBRATION UNTIL 250. THEN INTERMITTENT. DELTA MX HELPED TROUBLESHOOT IN AIR. WE TURNED THE L PACK TO STBY AND WE DIDN'T HAVE THE VIBRATION. CORRECTIVE ACTION: REMOVED AFT CARGO AFT WALL PANEL FOR INSPECTION. REMOVED FWD CARGO AFT WALL PANELS AND REMOVED RT RECIRC FAN TO BE REPLACED. C/W ODI CHECKLIST, FOUND AFT EQUIP VENT FAN 2 PRODUCING STRONG METALLIC SMELL AND HIGH VIBRATIONS. R&R AFT VENT FAN 2 PER B757 AMM 21-26. OPS CHECK GOOD. INSTALLED NEW RT RECIRC FAN PER B757 AMM 21-25. OPS CHECK GOOD. REINSTALLED CARGO PANELS PER B757 AMM 25-50. (9957564)
SHIP 5807 DENT FOUND ON TAIL CONE AFTER OF VERTICAL FIN ABOVE APU. CORRECTIVE ACTION: INSTALLED TIME LIMITED REPAIR PER B757-- 300 SRM 53-80-01-1A NOTE "C". (2755875)
SHIP 5807 FROM NR# 344 - GIRT BAR LEAF SPRINGS FAIL TO RETAIN SLIDERS AT R2 DOOR. CORRECTIVE ACTION: REMOVED AND REPLACED GIRT BAR REF B757 AMM 25-66-10. (2749336)
SHIP 5807 AFT CARGO DOORWAY, LWR THRESHOLD SUPPORT STRUCTURE HAS LIGHT SURFACE CORROSION SEVERAL PLACES FROM STA 1380R TO 1440R CORRECTIVE ACTION: SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0265:2550-3006/005 00222 REPLACED TRANSITION PANEL REF B757-300 SRM. (2744497)
SHIP 5807 EXISTING REPAIR WAS FOUND IN THE INSPECTION AREA (OVERSIZE HOLE) AT STA 1640 AT LOWER I/B HOLE COMMON TO I-14F TEE. REF: ERA 590914-14. REF: STEP 4 OF AMDS 5311-01218-01A. REF N/R 226. CORRECTIVE ACTION: BHEC COMPLIED WITH ON OVERSIZED FASTENER HOLE WITH NO ITEMS NOTED REF ERA 59014-14AD CASTLE 8100-9 ID#202103100127-0003. OK TO CONTINUE WITH AMDS CARD 5311-01218-01A. C/W CARD 5311-01218- 01A STEP 12. (2737794)
SHIP 5807 PASSENGER R2 DOOR CAM PLATE UPPER RUSTED ON (NR 109 ATG TASK CARD. CORRECTIVE ACTION: C/W ER/A 476391-14MA REV B SECTION ONE ON NR 0109 TASK CARD 0591 -0201/002. REF SECTION II. (2736516)
SHIP 5807 PASSENGER R2 DOOR LOWER CAM PLATE RUSTED (NR 109 ATG TASK CARD 0591-0201/002). CORRECTIVE ACTION:C/W ER/A 476391-14MA REV B SECTION ONE ON NR 109 ATG TASK CARD 0591-0201/00. REF SECTION II. (2736520)
SHIP 5807 SNUBBER BEYOND LIMITS PASSENGER L-2 DOOR. CORRECTIVE ACTION: SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0183:2040-0191-2L/ 001 00130 REPLACED DOOR SNUBBER REF B757 AMM 52-11-10. (2728409)
SHIP 5807 DOOR 2L CLOSES BUT SLIDE WILL NOT ARM. CORRECTIVE ACTION: REMOVED DEBRIS FROM GIRT BAR FITTING. NOW CKS GOOD. (9600748)
FOUND SEAT MOUNTED EMERGENCY LIGHT AT 42 DEF INOP. FOUND DAMAGED SPLICE AT SEAT ROW 42 REPLACED SPLICE PER BOING SWPM 20-30-00. OPS CHECK GOOD. (9568795)
SHIP 5807 DURING MEET & GREET RAMP REPORTED AFT CARGO DOOR DENTED ON LOWER FWD CORNER OF DOOR. CORRECTIVE ACTION: REMOVED INNER SKIN PANEL FOR ACCESS TO DAMAGE AREA AND REMOVE FASTENERS IAW B757-300 SRM. CUTOUT DAMAGE IAW B757-300 SRM 52-30-01. FABRICATED REPAIR PARTS IAW B757-300 SRM. TREATED & PRIMMED REPAIR PARTS AMD CUT OUT AREAS IAW B757-300 SRM. INSTALLED DOUBLER & FILLER COMPLETETED THRU STEP 13. PER B757 SRM. ACOMPLISHED STEP 14 AND 15 PER B757-300 SRM. (9568769)
SHIP 5807 REPAIR TO RH WING UPPER SKIN COMMON TO DRAG FITTING ATTACHMENT REQUIRES SUPPLEMENTAL INSPECTIONS PER ERA 590477-14AD REV A. CORRECTIVE ACTION: REF ERA 590477-14 REV A. (2460715)
SHIP 5807 MAIN ENTRY DOOR #2L EXTERIOR EMERGENCY SLIDE LIGHT INOP. CORRECTIVE ACTION: REPLACED EMERGENCY LIGHT PWR SUPPLY AND BATT. M11613 REF B-757 IPC 33-51-07. (9124616)
SHIP 5807 - MISC/DE - DUE TO TE FLAP DISAGREE MSG. CORRECTIVE ACTION: REPLACED RT OUTBOARD TRANSMISSION DUE TO POPPED TORQUE INDICATOR. DRAIN AND FILLED REMAINING TRANSMISSIONS. PERFORMED FOQA DOWNLOAD PER ETS REQUEST.
SHIP 5807 1R DOOR WILL NOT ARM. CORRECTIVE ACTION: REMOVED TRASH UNDER GIRTBAR PER B757 AMM 52-11, CHKD OK.(8797244)
SHIP 5807 4R DOOR WOULD NOT ARM CYCLED SEVERAL TIMES. CORRECTIVE ACTION: CYCLED DOOR OPENED/CLOSED DOOR ARMS DISARMS. OK TO CONT. WORK DONE IAW 52-11. (9109266)
SHIP 5807 4R DOOR WOULD NOT ARM , CYCLED SEVERAL TIME. CORRECTIVE ACTION: CYCLED DOOR OPEN / CLOSE DOOR ARMS DISARMS IAW B757 AMM 52-11. (9109226)
SHIP 5807 DOOR 1R SLIDE LIGHT INOP. CORRECTIVE ACTION: CLEANED 1R SLIDE LIGHT IND. PROX SENSORS AND LUBED GIRT BAR FLOOR FITTINGS. SLIDE IND. AT 1R CKS OK, REF B757 AMM 25-66. (8438480)
SHIP 5807 SLIDE INDICATOR LIGHT INOP OR DAMAGED / LOCATIONS: 1R. CORRECTIVE ACTION: FOUND DEBRIS KEEPING GIRT BAR FULL ENGAUGEMENT. REMOVED DEBRIS FROM GIRT BAR AND SENSOR AREA IAW B757 AMM 52-71. OPS CHK NML. (2349373)
SHIP 5807 R1 DOOR WOULD NOT ARM. CORRECTIVE ACTION: REMOVED OBSTRUCTION. CHKS OK. (8438412)
SHIP 5807 2L DOOR GUST LOCK BROKEN. CORRECTIVE ACTION: REMOVED BROKEN GUST LOCK COLLAR AND CATCH. INSTALLED NEW HOLD OPEN COLLAR & CATCH PER B757 AMM 52-11. CHECKS GOOD. (8438406)
SHIP 5807 R1 ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT INOP. CORRECTIVE ACTION: OPENED R1 DOOR AND FOUND CORD HANGIN IN WAY OF GIRT BAR PLACED CORD BACK IN DOOR BUSTLE OPS CHK ARM AND DISARM MECHANISM SLIDE LIGHT ILLUMINATES. (2289107)
SHIP 5807 OVERWING EXIT SIGN IN MIDDLE OF CABIN MISSING. CORRECTIVE ACTION: REPLACED SIGN OPN CHECKS GOOD. (8513050)
SHIP 5807 1R DOOR WON'T ARM. CORRECTIVE ACTION: REMOVED DEBRIS. DOOR CHKS OK. REF B757AMM 25-66. (8725516)
SHIP 5807 -MISC/DE- DECLARED EMERGENCY DUE TO TRAILING EDGE DISAGREE LIGHT ILLUMINATED WITH "FLAP DISAGREE" EICAS MESSAGE WHEN SELECTING FLAPS 25 DURING APPROACH. CORRECTIVE ACTION: COMPLETED FIM / NO GO TASKS. PERFORMED BITE OF FSEU WITH NO FAULTS. FOUND NUMBER 1 FLAP TORQUE LIMITER TRIPPED. DRAINED AND SERVICED TRANSMISSION. CYCLED FLAPS/SLATS SEVERAL TIMES WITH NTF.
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RIGHT SIDE STRINGER 6 APPROX STA 653. CORRECTIVE ACTION: PERFORM DETAIL VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1. DAMAGE CLEANUP IS COMPLETE. (2175756)
SHIP 5807 POSSIBLE LIGHTNING STRIKE RIGHT SIDE FUSELAGE STATION 740 2" BELOW STRINGER 5. CORRECTIVE ACTION: PERFORM DETAIL VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1. DAMAGE CLEANUP IS COMPLETE. (2175748)
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RT SIDE 3" ABOVE STRINGER 6 APPROX STA 701. CORRECTIVE ACTION:PERFORMED DETAILED VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1 DAMAGE CLEANED UP COMPLETE. (2175751)
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RT 1" ABOVE STRINGER 7 APPROX STA 620. CORRECTIVE ACTION:PERFORMED DETAILED VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1. DAMAGE CLEAN UP COMPLETE. (2175759)
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RIGHT SIDE 1" ABOVE STRINGER 7 APPROX STA 612. CORRECTIVE ACTION: PERFORM DETAIL VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1. DAMAGE CLEANUP IS COMPLETE. (2175762)
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RT SIDE STRINGER 8 APPOX STA. 530. CORRECTIVE ACTION: PERFORMED DETAILED VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1. DAMAGE CLEAN UP COMPLETE. (2175765)
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RIGHT SIDE 5" BELOW STRINGER 9 AT STATION 440. CORRECTIVE ACTION: PERFORM DETAIL VISUAL INSPECTION. DAMAGE MEETS LIMITS PER B757 SRM 53-00-01-1A-1. DAMAGE CLEANUP IS COMPLETE. (2175766)
SHIP 5807 POSSIBLE LIGHTNING STRIKE FUSELAGE RT SIDE BETWEEN STRINGERS 8 AND 9 APPROX STA 488. CORRECTIVE ACTION: REMOVED DAMAGE FROM SKIN INSPECTED WITH 10X MAGNIFIED GLASS NO DEFECTS NOTED. INSTALLED BLIND FASTENER PER B757 SRM 53-00-01. (2175729)
SHIP 5807 EMER EXIT LT AT DR 3 MISSING LENS O. CORRECTIVE ACTION: INSTALLED MISSING EMERGENCY LIGHT LENS. (8147798)
SHIP 5807 1 RIGHT DOOR WILL NOT ARM. CORRECTIVE ACTION: REMOVED DEBRIS, CKS GOOD. (8311928)
SHIP 5807 AFT LEFT UPPER LIFE RAFT PRESSURE CYLINDER READ 1800 PSI ON GAUGE (DOOR ASSIST BOTTLE). CORRECTIVE ACTION: REMOVED AND REPLACED 4L DOOR ASSIST RESERVOIR PER B757 AMM 52-11. (7867474)
SHIP 5807 UNABLE TO ARM R1 DOOR. CORRECTIVE ACTION: FOUND EXCESS SLIDE ATTACHMENT LANYARD DANGLING FROM SLIDE. STOWED EXCESS LANYARD AND OPS CHECK NORMAL. (7867450)
SHIP 5807 1R DOOR DIFFICULT TO ARM. CORRECTIVE ACTION: T/S PER FIM 52-11-00-815-813. NO DEFETS NOTED ON GIRT BAR & FLOOR FITTING. GIRT BAR ENGAGED NO PROBLEM. PERFORMED GIRT BAR LUBE ON 1R DOOR. IAW B757 AMM 12-21. OPS CHECK GOOD.
SHIP 5807 R1 DOOR ARMING LEVER WILL NOT ARM. CORRECTIVE ACTION: REMOVED DEBRIS. SYSTEM OPERATION IS NORMAL. (LP 7525224)
SHIP 5807 1R DOOR WILL NOT ARM. CORRECTIVE ACTION:OPENED DOOR CLEARED OBSTRUCTION. CLOSED DOOR. NOW ARMS PROPERLY. (7525200)
SHIP 5807 R1 ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT INOP. CORRECTIVE ACTION: FOUND OBSTRUCTION IN DOOR 1R GIRT BAR TRACK - REMOVED. SLIDE ARMED LIGHT WORKING GOOD NOW. REMOVED PLACARDS. (1842674)
SHIP 5807 1R DOOR DOES NOT CLOSE CORRECTLY KNUCKLE KNOCKER WON'T EXTEND. CORRECTIVE ACTION: MOVED LOOSE DOOR TRIM INSULATION THAT WAS BLOCKING 1R DOOR KNUCKLE KNOCKER FROM EXTENDING. NOW IT EXTENDS WHEN ARMED. (7827428)
SSHIP 5807 PASSENGER O2 MASKS DEPLOYED AFTER LANDING. LANDING WAS NOT FIRM. CORRECTIVE ACTION: REMOVED AND REPLACED O2 GENERATORS AND REPLACED MASK FOR SEATS 2AB, 17ABC, 18DEF, 21 ABC PER B757 AMM 35-21. T/S PER B757 FIM 35-21-00-815-805, CONFIRMED X2 TO GND AT K4 RELAY WAS OPEN. X2 TO C1 AT K7 RELAY CHECKS GOOD. FOUND ALTITUDE PRESSURE SWITCH BROKEN AT PLUG. R/R ALTITUDE PRESSURE SWITCH OPS CHK PENDING. REF B757 WDM 32-21-11. R&R O2 GENERATORS REPACKED MASKS AT SEATS 22DEF,23ABC, 28BC, 30ABC, 33ABC, 33DEF, 34ABC. 44DEF PER B757 AMM 35-21. RFID TAGS SCANNED & UPLOADED (399486). PERFORMED ALTITUDE PRESSURE SWITCH TEST PER B757 AMM 35-21. OPS CHECK GOOD. MASKS STOWED. (7827416)
SHIP 5807 UPON SMOOTH MAIN GEAR TOUCHDOWN, THE AUTO BRAKES AT SETTING 3 AGGRESSIVELY ENGAGED AND CAUSED THE NOSE GEAR TO TOUCHDOWN FIRMLY RESULTING IN ACTIVATION OF DEPLOYMENT OF PAX O2 MASKS. CORRECTIVE ACTION: DAMAGE OR ISSUES NOTED. REINSTALLED PAX O2 MASKS EXCEPT FOR ONES WHERE GENERATORS NEED REPLACING. REF LP 7827410 FOR O2 GEN AND MASK REPLACEMENT. PERFORMED ANTI-SKID/AUTOBRAKE BITE PER B757 FRMFIM 32-42-00-815-802 NO FAULTS NOTED. AUTOBRAKE /ANTI-SKID SYSTEM OPERATED NORMALLY BY AIR/GROUND LOGIC ON MAIN WHEEL TOUCHDOWN AND GREATER THAN 60KNOTS SPEED. ALL OPS NORMAL. REPLACED EMER LIGHT/PAX O2 PANEL (M00043) IAW B757 AMM 33-51 TEST OF EMERGENCY LIGHTS / PASS OXY CONTROL PANEL OK. (7827404)
SHIP 5807 MISSING THREAD ON EXCESS GIRT MATERIAL AT R4 DOOR SLIDE. CORRECTIVE ACTION: SUMMARY OF NRC 00176. PASSENGER DOOR SLIDE WAS REPLACED BY SERVICEABLE PASSENGER DOOR SLIDE. (1781318)
SHIP 5807 DAMAGES WERE FOUND ON OPEN HOLES AT RH ENG DRAG FTG CLAMP-UP & DIAG BRACE AS FOLLOW; HOLE #2 SCRATCHES AND CORROSION ON SKIN AND FITTING AT 4 O CLOCK POSITION, HOLE #7 SCRATCHES ON FITTING AT 7 O?CLOCK POSITION PER CARD. CORRECTIVE ACTION: SUMMARY: OF NRC 00551 (CORROSION LEVEL 2) HOLES #2 AND #7 WERE REPAIRED PER ER/A 590477-14AD REV. ORIGINAL; SECTION I: PERMANENT REPAIR AND ETI 57-21-124 REV.7. (1777829)
SHIP 5807 CORROSION ON FRAME STA 1460 BTW S29 AND S30R. CORRECTIVE ACTION: SUMMARY ON REFERENCE NRC 00407: FRAME WAS REPAIRED PER ER/A 590989-14 REV. ORIGINAL AND ETI-57-21-153 REV.2. (1776022)
SHIP 5807 PREVIOUS BLEND OUT ON OUTER SKIN, BTW STA 520 TO 540 BELOW S14L AT FUSELAGE. CORRECTIVE ACTION: SUMMARY ON REFERENCE NRC 01109: EXISTING BLEND OUT WAS REPAIRED PER ETI-57-21-164 REV. 2 AND ER/A 590902-14 REV. ORIGINAL. (1775778)
SHIP 5807 SEVERAL CRACKS AT L-4 DOOR INNER SKIN ( UPPER HINGE SUPPORT AREA) LOCATED 9 INCHES BACK FROM FWD EDGE, 24 INCHES DOWN OF UPPER BEAM. CORRECTIVE ACTION: SUMMARY OF NRC 01064: L-4 DOOR INNER SKIN WAS REPAIRED PER ETI-57-21-140 REV 3 AND ER/A: 590960-14 REV. ORIGINAL. (1773966)
SHIP 5807 CORROSION ON SEAT TRACK FLANGE STA. 620 AND 680, RBL 25 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 01025: SEAT TRACK WAS REPAIRED PER ER/A: 590916-14 REV. ORIGINAL. (1770950)
SHIP 5807 CRACK WAS FOUND ON HOLE ON STA 1180+80 APROX BTW S-2L AND S-3L. CORRECTIVE ACTION: SUMMARY OF NRC 00795:HOLE ON STA 1180+80 APROX BTW S-2L AND S-3L WAS REPAIRED PER ERA 590742-14 REV.ORIGINAL. (1771513)
SHIP 5807 DTE/MONITOR INSP. LOG REF. ER/A 590852-14 FUSELAGE / SKIN / STA 620-640, S-17L & S-18L / DENT, FUSELAGE SKIN, STA. 620-640, S-17L ? S-18L, DENT. CORRECTIVE ACTION: REF ERA 590852-14. (1771257)
SHIP 5807 INITIAL INSPECTION: NICKS (4 EAS) ON INBD MAIN FLAP, LOWER SKIN BTW. MF STA 240 TO MF STA 300 AT RH WING. CORRECTIVE ACTION:SUMMARY OF NRC 00980 NICKS ON INBD MAIN FLAP, LOWER SKIN BTW. MF STA 240 TO MF STA 300 AT RH WING WERE BLENDED OUT PER B-757-300 SRM. FOUND TO BE OUT OF LIMITS AND WILL BE ATTENDED UNDER NRC 01135. (1770007)
SHIP 5807 AWR: A.A: HIDDEN DAMGE: ELONGATED HOLE ON INTERSCOSTAL TEE CLIP AND FRAME STA. 1640, S-14L AT INNER FUSELAGE STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00362: HOLE ON INTERSCOSTAL TEE CLIP AND FRAME STA. 1640, S-14L AT INNER FUSELAGE STRUCTURE WAS REPAIRED PER ER/A: 590914-14 AD, REV. ORIGINAL. (1770581)
SHIP 5807 ERA 590914-14AD ISSUED FOR REPAIR AT STA 1640, I14L. CORRECTIVE ACTION: REF ERA 590914-14AD. (1769648)
SHIP 5807 CORROSION ON ANGLE SUPPORT BTW STA 992 TO 1049, RBL 65 AT WING BOX AREA. (IN REF. NRC 00702). CORRECTIVE ACTION: SUMMARY OF NRC 01070: ANGLE SUPPORT BTW STA 992 TO 1049 WAS REPAIRED PER B757-300 SRM. (1766591)
SHIP 5807 CORROSION ON ANGLE SUPPORT BTW STA 1015 TO 1040, LBL 65 AT WING BOX AREA. (CPAX) (IN REF. NRC 00705). CORRECTIVE ACTION: SUMMARY OF NRC 01072:(CORROSION LEVEL 2) ANGLE SUPPORT BTW STA 1015 TO 1040, LBL 65 WAS REPAIRED PER B757-300 SRM. (1766973)
SHIP 5807 INITIAL INSPECTION: CORROSION ON NUT OF PNEUMATIC ACTUATOR STA. 1640, BTW S-11R TO S-13R AT INTERNAL FUSELAGE ESTRUCTURE. SUMMARY OF NRC 00732: EMERGENCY PNEUMATIC POWER ACTUATOR FROM DOOR R4 WAS REMOVED AND EMERGENCY PNEUMATIC POWER ACTUATOR WAS INSTALLED PER B757-300 AMM 52-11.(1766980)
SHIP 5807 CORRORION ON ANGLE SUPPORT STA. 956, LBL 65 AT WING BOX AREA. CORRECTIVE ACTION: SUMMARY OF NRC 00704: ANGLE SUPPORT ANGLE SUPPORT STA. 956, LBL 65 WAS REPAIRED PER B757-300 SRM. (1766597)
SHIP 5807 CORROSION ON SEAT TRACK FLANGE BTW STA. 620 TO 640, RBL 25 AND RBL 45 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00714; CORROSION ON SEAT TRACK FLANGE BTW STA. 610 TO 640, RBL 25 AND RBL 45 AT PASSENGER FLOOR STRUCTURE WERE REPAIRED PER B757-300 SRM. (1765793)
SHIP 5807 CORROSION ON SEAT TRACK FLANGE BTW STA. 620 TO 640, RBL 25 AND RBL 45 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00714; CORROSION ON SEAT TRACK FLANGE BTW STA. 610 TO 640, RBL 25 AND RBL 45 AT PASSENGER FLOOR STRUCTURE WERE REPAIRED PER B757-300 SRM.(1765795)
SHIP 5807 INITIAL INSPECTION:CORROSION ON DOUBLER LBL=2.5 TO RBL=2.5 AND FS= 1681 AT W-4. CORRECTIVE ACTION: SUMMARY OF NRC 00670 : CORROSION LEVEL 2 ON DOUBLER LBL=2.5 TO RBL=2.5 AND FS= 1681 AT W-4 WAS REPLACED PER B757-300 SRM. (1763243)
SHIP 5807 INITIAL INSPECTION: CORROSION ON INTERCOSTAL FROM STA 1520 TO 1540 BTW S29 AND 30R. CORRECTIVE ACTION: SUMMARY OF NRC 00411: CORROSION ON INTERCOSTAL FROM STA 1520 TO 1540 BTW S29 AND 30R WAS REPAIRED PER B757-300 SRM. (1763195)
SHIP 5807 INITIAL INSPECTION: CORROSION ON STRINGERS 2.90, 7.55, 10.45, 16.10 RH STA 1328. CORRECTIVE ACTION: SUMMARY OF NRC 00396: CORROSION ON STRINGERS 2.90, 7.55, 10.45, 16.10 RH STA 1328 WERE REPAIRED PER B-757-300 SRM. (1763240)
SHIP 5807 DURING REMOTION OF FASTENER, TOOL MARKS WERE FOUND ON INTERSCOSTAL TEE CLIP OF FRAME STA. 1640, S-14 RH INTERCOSTAL AT INNER STRUCTURE OF FUSELAGE. (IN REFERENCE AMDS. CORRECTIVE ACTION: SUMMARY OF N.R.C. 00359. DAMAGE TEE CLIP OF FRAME STA. 1640, S-14 RH, WAS REPLACED. PER. B757-300 SRM. (1763533)
SHIP 5807 INITIAL INSPECTION: CORROSION ON STRINGERS 2.90, 7.55, 10.45,16.10 LH STA 1328. CORRECTIVE ACTION: SUMMARY OF NRC 00395: CORROSION LEVEL 2 ON STRINGERS 2.90, 7.55,10.45, 16.10 LH STA 1328 WERE REPAIRED PER B-757-300 SRM. (1763236)
SHIP 5807 CORROSION ON ANGLE SUPPORT STA 1170, LBL 65 AT WING BOX AREA. CORRECTIVE ACTION: SUMMARY OF NRC 01077: CORROSION LEVEL 2 ON ANGLE SUPPORT STA 1170, LBL 65 AT WING BOX AREA WAS REPAIRED PER. B757-300 S.R.M. (1762818)
SHIP 5807 CORROSION ON ANGLE SUPPORT BTW STA 1058 AND 1078 TO 1082, RBL 65 AT WING BOX AREA. (CPAX) (IN REF. NRC 703). CORRECTIVE ACTION: SUMMARY OF NRC 01071: CORROSION LEVEL 2 ON ANGLE SUPPORT BTW STA: 1058 AND 1078 TO 1082, RBL 65 AT WING BOX AREA.WAS REPAIRED PER. B757-300 S.R.M. (1762944)
SHIP 5807 INITIAL INSPECTION: CORROSION ON ANGLE SUPPORT BTW STA. 759 TO 780, RBL 65 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00717: CORROSION LEVEL 2 ON ANGLE SUPPORT BTW STA 759 TO 780, RBL 65 AT PASSENGER FLOOR STRUCTURE WAS REPAIRED PER B757-300 S.R.M. (1761332)
SHIP 5807 CORROSION ON FLOOR STRINGER 7.55 LBL, STA 622 AT FWD CARGO COMPARTMENT. (CCD). ( IN REF. TO NRC 00315 AND 01063). CORRECTIVE ACTION: SUMMARY OF NRC 01097: CORROSION LEVEL 2 ON FLOOR STRINGER AT FWD CARGO COMPARTMENT WAS REPAIRED PER B757-300 SRM. (1761303)
SHIP 5807 HIDDEN DAMAGE: AFTER REMOTION ANGLE, ELONGATED HOLES WERE FOUND ON INTERCOSTAL BTW STA.1580-1600 BL. 0 AT PASSENGER FLOOR STRUCTURE, IN REF NRC.00571. CORRECTIVE ACTION: SUMMARY OF NRC 1076 : INTERCOSTAL BTW STA.1580-1600 BL. 0 AT PASSENGER FLOOR STRUCTURE WAS REPAIRED PER B757-300 SRM. (1762008)
SHIP 5807 CRAKED AND BENT FILTER HOUSING SUPPORT AT AIR DISTRIBUTION BAY LH SIDE. CORRECTIVE ACTION: SUMMARY OF NRC 1085: HOUSING SUPPORT AT AIR DISTRIBUTION BAY LH SIDE WAS REPAIRED PER B757-300 SRM. (1760517)
SHIP 5807 REPLACE ROTARY SNUBBER DUE TO FAIL CHECK STEP 4B2 IN REFERENCE CARD. CORRECTIVE ACTION: SUMMARY OF NRC 00913: SNUBBER AT DOOR L2 WAS REPLACED FOR SERVICEABLE ROTARY SNUBBER PER B757-300 AMM 52-11. (1759653)
SHIP 5807 CORROSION ON FLOOR CHANNEL SUPPORT STA. 700 TO 720, LBL 63 IN ORDER TO PERFORM NRC 721. CORRECTIVE ACTION: SUMMARY OF NRC: 01004. CORROSION LEVEL: 2. FLOOR CHANNEL SUPPORT STA. 700 TO 720, LBL 63 WAS REPAIRED. B757-300 SRM. (1759672)
SHIP 5807 CORROSION ON INTERCOSTAL, BTW S-29R TO S-27R, BTW STA.1540 TO 1560 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC.00985: INTERCOSTAL WAS REPLACED PER B757-300 SRM. (1759499)
SHIP 5807 REPLACE ROTARY SNUBBER DUE TO FAIL CHECK. CORRECTIVE ACTION: REPLACED SERVICEABLE SNUBBER. (1758482)
SHIP 5807 CORROSION ON FLOOR SUPPORT BTW STA. 720 TO 740, LBL 60 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00723: CORROSION ON FLOOR SUPPORT BTW STA. 720 TO 740, LBL 60 WAS REMOVED PER B757-300 SRM AND FOUND TO BE OUT OF LIMITS. REPAIRED PER B757-300 SRM. (1758307)
SHIP 5807 INITIAL INSPECTION: CRACK ON STABILIZATION STRAP STA. 720. CORRECTIVE ACTION: SUMMARY OF 00728: CRACK ON STABILIZATION STRAP STA. 720, RBL 25 AT PASSENGER FLOOR STRUCTURE WAS REPAIRED PER B757-300 SRM. (1757894)
DURING INSPECTION MAINTNENACE FOUND BROKEN STABILIZER STRAP BTW STA 365 377 AND 25 LBL AT MAIN EQUUIPMENT CENTER. AND REPAIRED PER SRM. (LP 1755294)
(AIRCRAFT 5807, L/P 7138262) 2L DOOR WOULDN'T ARM FOR DEPARTURE. CORRECTIVE ACTION: REMOVED DEBRIS FROM GIRT BAR AREA. OPS OK PER B757 AMM 5211.
FOUND THE PAX SEAT EMERGENCY LIGHTS AT SEATS 46 - 49 WERE INOPERATIVE. FOUND THE POWER SUPPLY FUSES ON M737 FAILED. R & R THE FUSES AND OPS CHECKED GOOD IAW AMM 33-51.
(AIRCRAFT 5807, L/P 6416222) 4R DOOR NOT ABLE TO CLOSE/SEAL PROPERLY. CORRECTIVE ACTION: SECURED 4R DOOR TRIM COVER-4R DOOR CLOSES AND ARMS/DISARMS NML-PER B757 AMM 25-66.
(AIRCRAFT 5807, L/P 6423330) WHILE CONFIGURING TO LAND WE GOT THE TE FLAP DISAGREE EICAS MESSAGE THE FLAP LEVER POSITION WAS SET AT 25 DEGREES, THE INDICATED POSITION WAS GREATER THAN 20 DEGREES, BETWEEN 20 AND 25, AFTER ENGINE SHUTDOWN FLAP'S MOVED TO INDICATE 20 DEGREE FLAP HANDLE AT 20 DEGREES. CORRECTIVE ACTION: FOUND RT OB FLAP TRANS TORQUE LIMITER TRIPPED, RESET R/H OB TORQUE LIMITER DRAINED AND SERVICED PER B757 AMM 12-13-06-603-029, LUBED R/H FLAP PER B757 AMM 12-21-09, T/S PER B757 FIM 27-51-00-815-805. FOUND TORQUE TUBE SECOND FROM END WITH EXCESSIVE WEAR AND MAKING LOUD SNAPPING SOUND EVERTIME FLAP'S MOVE. REMOVED BAD TORQUE TUBE PER B757 AMM 27-51-25-022-001. INSTALLED TORQUE TUBE AND OP'S CKD PER B757 AMM 27-51-25-422-016 NO FAULT'S ALSO COMPLIED WITH NO GO ODI PREVENTION PER 27-55 THE FLAP'S DISAGREE OK FOR SVC.
SHIP 5807 ACS REPORTS DOOR 2L CLOSING PROBLEMS. CORRECTIVE ACTION: FOUND AFT PART OF GIRT BAR NOT FULLY ATTACHED TO SLIDE. RECONNECTED & OPS CK GOOD. (5511362)
(AIRCRAFT 5807, L/P 5510582) MID ENTRY DOOR (L2) OPEN DOES NOT SHOW ENTRY DOORS OVERHEAD LIGHT OR EICAS CAUTION. REMOVED DEBRIS FROM DOOR 2L PROX SWITCH, SWITCH OPERATES SMOOTHLY ALL INDICATIONS NORMAL.
COFFEE MAKER FORWARD GALLEY HAD SPARK THEN SMOKE WHEN ACTIVATED. TURNED OFF UTILITY BUSES. LOCATION F105 #1. REPLACED COFFEE MAKER PER B757 AMM 25-31. OK FOR SVC.
SHIP 5807 PILOT REPORTS THE L4 DOOR SLIDE MOORING CORD IS EXPOSED FROM BOTTOM OF BUSTLE. CORRECTIVE ACTION: RESTOWED CORD BACK INTO BUSTLE COVER. (5764320)
SHIP 5807 EICAS MSG EQUIP OVHT. QRH COMPLETED LIGHT OUT IN ALT. ON TAKE OFF BOTH PILOTS SMELLED ELECT, SMOKE DISIPATED RETURNED DISIPATED AGAIN. CORRECTIVE ACTION: R/R #1 EQUIPMENT COOLING FAN AND FILTER. (5273434)
(AIRCRAFT 5807, L/P 0801475) EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS: 3C / INTERIOR. REMOUNTED EMER LT AT 3C. OK FOR SVC.
(AIRCRAFT 5807, L/P 4561284) SEAT 35 DEF EMERGENCY LIGHT ASSY MISSING. INSTALLED NEW EMER LIGHT ASSY AT SEAT 35 D. OPS CK GOOD.
2R DOOR EMERGENCY EXIT SIGNAGE FELL OFF IN FLIGHT. REATTACHED 2R DOOR EMERGENCY EXIT SIGNAGE.
L2 DOOR EMERGENCY EXIT LIGHT SIGN INOP. REPLACED EMERGENCY LIGHT POWER SUPPLY AND BATTERY PER AMM 33-51-07, OPS OK.
DOOR 3 OVERHEAD EXIT SIGN NEEDS TO BE ATTACHED. REPLACED THE LIGHT ASSY.
L4 DOOR WILL NOT ARM. REMOVED DEBRIS FROM FWD EDGE OF THE GIRT BAR FITTING.
AFT CARGO DOOR THRESHOLD LOWER SILL CORROSION ON LOWER SUPPORT ANGLE BETWEEN STA 1380 AND 1440. REPAIRED AFT CARGO DOOR THRESHOLD LWR SILL BTWN STA 1380-1440 IAW PRI 567743-14 REV O, REV 1 AND ERA 567743-14 REV ORIG.
STA 760 ABOVE STR 16L FUSELAGE SKIN DENT. 53-00-01 REPAIR 3 FIG 201. NO DAMAGE NOTED ON FRAME FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-01 REPAIR 3.
STA 640 STR 17L SKIN DENT. DENT AT STA 640 STR 17L. REPAIRED IAW ERA 567742-14 REV O.
EMERGENCY LIGHTS AT SEAT ROWS 1, 2 AND 3 INOPERATIVE. REPLACED THE POWER SUPPLY M731 IAW AMM 33-51. OPS CHECKED NORMAL.
SEAT 39-40 EMERGENCY LIGHT INOPERATIVE. FOUND TWO BROKEN WIRES. REPAIRED THE WIRES. REMOVED AND REPLACED THE POWER SUPPLY, OPS CHECKED OK 20-90-03.
ISLE EMERGENCY LIGHTS FROM ROWS 27 - 40 ARE INOPERATIVE. TROUBLESHOT IAW WDM 33-51-11. FOUND A BAD FUSE IN THE M11487 POWER SUPPLY. REPLACED THE POWER SUPPLY. OPS CHECKED OK.
FOUND EXIT SIGN MISSING AT THE L3 & R3 DOORS DURING A WAKE UP CHECK. REPLACED THE MISSING EXIT SIGN.
SEAT 39 DEF EMERGENCY LIGHT INOPERATIVE. FOUND DISCONNECTED PINS AT THE BASE OF THE SEAT. REPAIRED THE PINS & OPS CHECKED GOOD.
R1 EXTERNAL DOOR HANDLE PUSH LATCH SPRING WAS FOUND BROKEN. REPAIRED IAW ERA 557498-14, REV ORIG. REPLACED R1 DOOR HANDLE EXTERNAL PUSH LATCH RETAINER SPRING. OPS CHECKED GOOD.
ELECTRICAL FUMES DETECTED INFLIGHT FROM COFFEEMAKER CIRCUIT BREAKER PANEL NEAR R2 DOOR. FOUND OVERHEAT DAMAGE ON COFFEEMAKER PC BOARD. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-31-12. NO FURTHER FUMES DETECTED. VERIFIED CORRECT VOLTAGE AT CONNECTOR.
NR 1 ENGINE PYLON FIREWALL AFT FIRE SEAL ATTACH ANGLE CRACKED. REPALCED FIRE SEAL SUPPORT IAW DWG 311N3570.
DURING FINAL INSPECTION OF RT WING, FOUND A PUNCTURE ON INBD MAIN FLAP T/E PANEL LOWER SURFACE, AT APROXIMATELY FLAP STA 161 AND 8 INCHES FROM AFT EDGE. REPAIRED PUNCTURE ON RT INBD MAIN FLAP LOWER SURFACE IAW SRM 51-70-07 & AMM 51-21-10-377-039.
DURING ZONE FINAL FOUND OUTWARD DENT IN SKIN WITH A CRACK AT BS 1275 STRINGER 25L. TRIMMED-OUT DENT AND INSTALLED PERMANENT REPAIR IAW SRM 53-00-01.
CREASE BEAM DAMAGED BS 1610-1630. REPAIRED RT CREASE BEAM IAW ER/A 524466-14, REV ORIGINAL.
CORROSION ON MAIN CABIN RT CUSP WEB AND ATTACHING RIVETS AT BS 1182. REPAIRED CUSP WEB IAW ER/A 524464-14, REV.
FOUND THE EMERGENCY MECHANISM AFT LIFTER SPACER CRACKED. R & R SPRING ASSY, SPACER, AT R-2 DOOR EMERGENCY MECHANISM AFT LIFTER, IAW CMM 52-11-15.
MAIN CABIN FUSELAGE, STRINGER 16R CRACKED AT BS 780+24. REMOVED AND REPLACED THE STRINGER SECTION IAW SRM 51-40-02 & DWG 143N3110, DWG 143N3800.
RIGHT HORIZONTAL STAB LOWER L/E FIXED COMPOSITE PANEL HAS A 16 INCH DENT.
AFT FUSELAGE SKIN HAS CHAFING WEAR AT AREA UNDER LT HORZONTAL STAB LOWER SLIDING FAIRING STATION 1800. ACCOMPLISHED ER/A 524465-14 REV ORIGINAL FOR A PERMANENT REPAIR.
STABILIZER STRAP IS SEVERED AT BS 377.7, LBL 45.50 AND IS CRACKED AT BS 375 BOTTOM OF FLOOR SUPPORT. REMOVED DAMAGE SECTION OF STABILIZER STRAP AND FABRICATED SPLICE REPAIR TREAT PRIME AND INSTALLED REPAIR APPLIED PROTECTIVE TREATMENT OF REPAIR AREA AND IDENTIFIED REPAIR AS ENGINEERING APPROVED AND PERMANENT PER ERA 384483-14MA
RIGHT HORIZONTAL STABILIZER LOWER L/E FIXED COMPOSITE PANEL HAS A 16 INCH DENT. REPAIRED DENT IAW SRM 51-70-10 & AMM 51-21.
SEAT TRACK SUPPORT AT RBL 24.75 BS 365.25 HAS CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. REMOVED AND REPLACED SEAT TRACK SUPPORT IAW SRM .
SEAT TRACK AT RBL 24.75 HAS CORROSION INSIDE SCALLOPS FROM BS 1290-1320. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-52. CUTOUT DAMAGE, FABRICATED REPAIRED AND INSTALLED SEAT TRACK IAW SRM 53-00-52.
MAIN CABIN FLOORBEAM BS 377.7 BL-0-LBL 53 DAMAGED. BLENDED DAMAGE AND FOUND OUT OF LIMITS. REMOVED DAMAGE AND ACCOMPLISHED PERM REPAIR IAW SRM 53-00-51.
SEAT TRACK AT LBL 24.75 HAS COROSSION INSIDE SCALLOPS AND FLANGES, BS 1290-1320. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 51-30-02. REMOVED DAMAGED SEAT TRACK AND INSTALLED NEW IAW SRM 53-00-52.
SEAT TRACK INBD FLANGE HAS CORROSION ABOVE FLOORBEAM AT BS 1320, LBL 24.75. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-52. REMOVED DAMAGED SEAT TRACK BS1320-1351 AND INSTALLED NEW SEAT TRACK IAW SRM 53-00-52.
MAIN CABIN FUSELAGE STRINGER 16L CRACKED AT BS 780+24 AT END OF STR. REMOVED, FABRICATED ON TRAVELER 70005936070001, AND INSTALLED STRINGER SECTION AND 2 EA STR CLIP, SPLICE IAW SRM.
DENT IN EXTERNAL FUSELAGE SKIN BS 200.5, 11" BELOW STR 20L LAP JOINT. REPAIRED IAW SRM 53-00-01.
STABILIZING STRAP IS CRACKED AT AFT CARGO BAY CEILING AREA FLOORBEAM BS 1660, RBL 24.7 REMOVED DAMAGED BS1650-1670 RBL 24.7 IAW ERA 384483-14MA REV D SH 2, STEP 7. FABRICATED STRAP AND TWO REPAIR SPLICES AND INSTALLED IAW ERA 384483-14MA, REV D SH 2 PARA 8, FIG 2 AND STEP 13.
FOUND AFT LENS OF LIGHTED EXIT SIGN IN AFT GALLEY WITH INCORRECT CONFIGURATION. REPLACED LENS WITH PROPER PART.
EMERGENCY LIGHTS HAVE INOPERATIVE BULBS. REPLACED BULBS. OPS NORMAL.
EMERGENCY LIGHTS AT OVERWING EXITS HAVE BULBS INOPERATIVE. REPLACED BULBS. OPS CHECKED GOOD.
DURING SERVICE WALKAROUND, FOUND SEVERAL NICKS FROM LIGHTING STRIKES ON LT FWD LOWER FUSELAGE SKIN. PERFORMED LIGHTING STRIKE CONDITION INSPECTION. NICKS FOUND WERE BLENDED AND FOUND TO BE WITHIN LIMITS IAW SRM CHAP 53-00. BLENDED AREAS WERE CLEANED TREATED PRIMED AND PAINTED.
DURING EMERGENCY LIGHT BATTERY PACK CHECK, FOUND BATTERY PACKS M11488, M11613, AND M11384 BAD. R & R BATTERY PACKS IAW AMM 33-51.
EMERGENCY LIGHTS AT SEAT 18D BULLNOSE AISLE LIGHT, SEAT 16D OVERHEAD DOME LIGHT (EMERGENCY LIGHT) AND FLT DECK ABOVE OBS SEAT INOPERATIVE. REPLACED LAMPS EMERGENCY LIGHTS AT 18D BULLNOSE (AISLE LIGHT), 16D EMERGENCY DOME LIGHT AND FLT DECK DOME LIGHT ABOVE OBS SEAT IAW AMM 33-51. OPS CHECKED GOOD.
EMERGENCY LIGHTS INOPERATIVE ON SEATS ROW 31 TO ROW 36. REPLACED FUSE ON BATTERY CHARGER M11082, OPS CHECKED GOOD, REF 33-5.
MAINTENANCE DISCOVERED THE R2 DOOR EMERGENCY POWER ACTUATION CABLE FAILED TEST. ADJUSTED R2 DOOR EMERGENCY POWER ACTUATION CABLE IAW B757-300 AMM 52--11. ADJUSTMENT CHECKS GOOD.
MAINTENANCE DISCOVERED THE R4 DOOR EMERGENCY POWER ACTUATION CABLE FAILED TEST. ADJUSTED R4 DOOR EMERGENCY POWER ACTUATION CABLE IAW AMM 52-11. ADJUSTMENTS CHECKED GOOD.
MAINTENANCE DISCOVERED THE L2 DOOR EMERGENCY POWER ACTUATION CABLE FAILED TEST. ADJUSTED L2 DOOR EMERGENCY POWER ACTUATION CABLE IAW B757-300 AMM 52--11. ADJUSTMENT CHECKS GOOD.
MAINTENANCE DISCOVERED THE L1 DOOR EMERGENCY POWER ACTUATION CABLE FAILED TEST. ADJUSTED L1 DOOR EMERGENCY POWER ACTUATION CABLE IAW B757-300 AMM 52--11. ADJUSTMENT CHECKS GOOD.
MX DISCOVERED FUSELAGE SKIN HAS LIGHTNING STRIKE AT BS 1180+95 AT STRINGER 3R. REMOVED DAMAGED FASTENER, HFEC INSPECTED HOLE, NO DAMAGE NOTED, INSTALLED BLIND FASTENER IAW SRM 53-00-01. REMOVED TEMP FASTENER, REAMED HOLE TO HOLE .185 CLEANED SURFACE. ACCOMPLISHED HFEC INSPECTION IAW REF 53-00-01 IAW NDTPM 51-00-19. NO DEFECTS NOTED TREATED AND PRIMED , INSTALLED SOLID RIVET IAW SRM 53-00-01, FIG 201 STEP 5. RESTORED ACCESS AND PAINTED. NO DEFECTS NOTED.
MX DISCOVERED THE FUSELAGE SKIN HAS LIGHTNING STRIKE AT BS 1180+37.5 AT STRINGER 3R. REMOVED DAMAGED FASTENER, HFEC INSPECTED HOLE, NO DAMAG E NOTED, INSTALLED BLIND FASTENER IAW SRM 53-00-01. REMOVED TEMP FASTENER, REAMED HOLE TO .262. CLEANED SURFACE. ACCOMPLISHED HFEC INSPECTION IAW SRM 53-00-01, IAW NDTSPM 51-00-19 PT 6, NO DEFECTS NOTED. TREATED AND PRIMED. INSTALLED HY-LOCK IAW SRM 53-00-01, FIG 201, STEP 5 & SRM 51-4--03 . RESTORED FINISH AND ACCESS.
MX DISCOVERED THE FUSELAGE SKIN HAS LIGHTNING STRIKE AT BS 1180-65.5 AT STRINGER 3R. REMOVED DAMAGED FASTENER, HFEC INSPECTED HOLE, NO DAMAGE NOTED, INSTALLED BLIND FASTENER IAW SRM 53-00-01. REMOVED TEMP FASTENER, REAMED HOLE TO .262 CLEANED AREA. ACCOMPL ISHED HFEC INSPECTION IAW SRM 53-00-01 IAW NDTSPM 51-00-19, PT 6, NO DEFECTS NOTED. TREATED & PRIMED INSTALLED HY-LOC IAW SRM 53-00-01 FIG 201 STEP 5 & SRM 51-40-03, RESTORED FINISH & ACCESS.
LIGHTNING STRIKE DAMAGE AT BS 719, S27R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.
LIGHTNING STRIKE DAMAGE AT BS 484, S27R DRILLED OUT DAMAGE AREA .125, 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECTION 1.
LIGHTNING STRIKE DAMAGE AT BS 889, S24R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.
LIGHTNING STRIKE DAMAGE AT BS 504, S26R. DRILLED OUT DAMAGE AREA .125, 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECTION 1.
LIGHTNING STRIKE DAMAGE AT BS 732, S27R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.
LIGHTNING STRIKE DAMAGE AT BS 541, S26R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.
LIGHTNING STRIKE DAMAGE AT BS 855, S25R. DRILLED OUT DAMAGE AREA .125, 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECTION 1.
LIGHTNING STRIKE DAMAGE AT BS 825, S25R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.
LIGHTNING STRIKE DAMAGE AT BS 522, S26R. DRILLED OUT DAMAGED AREA, .125 INCH DIAMETER 10X VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT 1.
LIGHTNING STRIKE DAMAGE AT BS 668, S28R, DRILLED OUT DAMAGED AREA .125 DIA, 10X VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT 1.
LIGHTNING STRIKE DAMAGE AT BS 880, S24R DRILLED OUT DAMAGE AREA .125, 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECTION 1.
LIGHTNING STRIKE ON FUSELAGE BS 780, 3 INCHES OUTBOARD S2R. DRILLED OUT DAMAGE, .125 INCH DIAMETER, 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201.
LIGHTNING STRIKE DAMAGE AT FUSELAGE BS 698, S27R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01FIG 201 SECT II.
LIGHTNING STRIKE ON FUSELAGE STATION 770 2 INCH OUTBOARD OF STRINGER 2 RT. DRILLED OUT DAMAGE .125 INCH DIAMETER, 10X MAG VISUAL INSPECTION. NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201.
AT ROTATION, FUMES WERE DETECTED IN THE COCKPIT AND CABIN. FLIGHT RETURNED TO MCO AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED A VISUAL INSPECTION OF THE AIRFRAME, ENGINE, AND APU AND NO OIL OR HYDRAULIC LEAKS WERE NOTED. A TAKEOFF POWER RUN WAS PERFORMED WITH BOTH ENGINES AND FULL OPERATION OF PACKS, APU, AND RECIRCULATION FAN ACCOMPLISHED WITH NO SMOKE OR FUMES NOTED. MAINTENANCE REPLACED THE RIGHT RECIRCULATION FAN AND FILTER AS PRECAUTIONARY.
EMERGENCY LIGHT AT OVERWING EXIT LEFT SIDE INSIDE INOPERATIVE. FORWARD BOTTOM LIGHT PLATE INOPERATIVE AND BATTERY DRAINED. MAINTENANCE REPLACED EMERGENCY BATTERY SUPPLY PACK. OPS NORMAL.
EMERGENCY LIGHTS AT DOOR 3L INSIDE INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY. OPS CHECK GOOD.
EMERGENCY LIGHTS AT DOOR 3L OUTSIDE INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY. OPS CHECK GOOD.
EMERGENCY LIGHTS OUTSIDE DOOR 2L INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY. OPS NORMAL.
DURING EMERGENCY LIGHT CHECK, FOUND EMERGENCY AISLE LIGHT FORWARD OF L3 DOOR INOP. REPLACED M11490 POWER SUPPLY AND BATTERY. LIGHT OPS CHECKED NORMAL.
DURING AN OVERNIGHT LINE CHECK THE EMERGENCY LIGHT AT DOOR THREE LEFT WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE ASSOCIATED BATTERY PACK TO BE INOPERATIVE AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY PACK WAS REPLACED.
DURING CRUISE MULTIPLE ENGINE NR 1 CONTROL MESSAGES ENUNCIATED AND LEFT ENGINE THRUST DID NOT RESPOND TO THRUST LEVER INPUT. FLIGHT CREW DIVERTED TO HNL, SHUTDOWN ENGINE NR 1 AT TOD AND PERFORMED AN UNEVENTFUL LANDING. MAINTENANCE REMOVED AND REPLACED ENGINE NR 1 PDIU, EEC AND THE STATOR/ALT.
AIRCRAFT RETURNED TO MSP DUE TO LOSS OF LEFT HYDRAULIC SYSTEM QUANTITY AND PRESSURE. AIRCRAFT LANDED WITHOUT INCIDENT AND WAS TOWED TO THE GATE. MAINTENANCE FOUND A DISCONNECTED SUPPLY LINE ON THE ENGINE DRIVEN HYDRAULIC PUMP. REMOVED AND REPLACED THE ENGINE DRIVE PUMP, BRAKE QUICK DISCONNECT AND FILTERS. RECONNECTED THE SUPPLY LINE, TESTED THE SYSTEM AND RETURNED TO SERVICE.
FLIGHT ATTENDANT REPORTED STRONG SMELL OF SMOKE AND FUMES. CO-PILOT COULD SMELL ELECTRICAL FUMES. AN EMERGENCY WAS DECLARED, DIVERTED TO HNL, AND LANDED UNEVENTFULLY. FOUND AIR CHECK VALVE AND CABIN RECIRCULATION FAN INOPERATIVE. REPLACED CHECK VALVE AND RIGHT RECIRCULATION FAN. OPERATIONAL CHECK GOOD.
DOOR 2L ARMING FLAP DOES NOT EXTEND WHEN DOOR IS ARMED. FOUND BOLT TO RETRACTABLE DOOR LINKAGE LEVERS BACKED OUT. REINSTALLED BOLT WITH LOCTITE PER EA 58-195881, SEC III AND PLACED ON MONITOR.
THE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EA 58-200472. OPERATIONAL CHECK GOOD.