N59083

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

29 reports on file, 1998-02-10 – 2006-08-23.

FLUID LOSS; WARNING INDICATION · 2006-08-23 Matched by certificate designator
ATA 2913

Part: SEAL — CUT (HYD PUMP) · airframe 114,968 hrs · 23,418 cycles

ABOUT 1.5 HRS INTO FLIGHT NR3 ENG OIL PRESSURE WENT TO 10 PSI, NR3 ENG OIL QUANTITY WENT TO ZERO. PERFORMED PRECAUTIONARY ENG SHUTDOWN NR3 ENG. UPON INSPECTION OF ENGINE FOUND HYDRAULIC PUMP LOCKOUT KIT LEAKING. REF DMI NR 8739. REMOVED LOCKOUT KIT AND FOUND SHAFT SEAL ON O-RING TO BE CUT. INSTALLED NEW SHAFT SEAL O-RING ON LOCKOUT KIT. REINSTALLED HYDRAULIC PUMP LOCKOUT KIT IAW MEL 29-1. PERFORMED ENGINE RUN IAW OAI JRH. RAN ENGINE FOR 5 MINUTES AFTER START UP AND STABILIZATION. ENGINE SPEED VARIED FROM IDLE TO FIGHT IDLE. NO OIL LEAKAGE NOTED FROM HYD PUMP LOCKOUT KIT. NO OIL CONSUMPTION NOTED. A/C OK FOR CONTINUED SERVICE. NOTE: ENGINE OIL SERVICED TO 18 QT ON COCKPIT INDICATOR.

Source: SDR CNMA20060023
SMOKE/FUMES/ODORS/SPARKS · 2006-06-24 Matched by certificate designator
ATA 2530

Part: OVEN — ODOR (GALLEY) · airframe 114,493 hrs · 23,327 cycles

WHEN FORWARD OVENS 307 & 308 WHERE TURNED ON A STRONG ODOR CAME FROM THEM. WHEN TURNED OFF ODOR DISSIPATED. CLEANED TRAYS BOTH OVENS 307 & 308, OPS CHECK, NO ODOR NOTED, GOOD FOR SERVICE. OMNI AIR IS CURRENTLY ADDING AN INTERVAL FOR CLEANING OVENS AND OVEN RACKS.

Source: SDR CNMA20060015
PARTIAL RPM/PWR LOSS · 2006-04-24 Matched by certificate designator
ATA 7603

Part: PUSH-PULL CABLE — BROKEN (NR 3 THROTTLE) · airframe 114,203 hrs · 23,267 cycles

DURING TAKEOFF ROLL NR 3 ENGINE WOULD NOT SPOOL UP. INDICATIONS DID NOT CHANGE NO MATTER THROTTLE POSITION. ENGINE REMAINED IN IDLE THRUST. ABORTED TAKEOFF AT 65KTS. FOUND THROTTLE PUSH-PULL CABLE BROKEN AT PYLON REMOVED AND REPLACED PUSH-PULL CABLE IAW MM 76-11. RAN ENGINE AND RIGGED PUSH-PULL CABLE IAW JRH ENGINE OPERATES NORMAL.

Source: SDR CNMA20060007
ELECT. POWER LOSS-50 PC · 2006-02-23 Matched by certificate designator
ATA 2432

Part: CHARGER — MALFUNCTIONED (MASTER BATTERY) · airframe 114,016 hrs · 23,229 cycles

DURING CLIMBOUT BATTERY VOLTAGE READ 0 WITH NO CLOCKS. BATTERY CHARGER RELAY RESET 2 TIMES IN-FLIGHT WITH BATTERY VOLTAGE NORMAL AND CLOCKS RETURNED. CHARGER FAILED AGAIN, BATTERY VOLTAGE 0 FOR REMAINDER OF FLIGHT WITH NO CLOCKS. ALL OTHER INDICATIONS NORMAL. REMOVED AND REPLACED BOTH A/C BATTERIES IAW 24-34-01 AND BATTERY CHARGER AS WELL AS THE BATTERY CHARGER RELAY PERFORMED BATTERY CHARGER TEST IAW 24-34 NO DEFECT NOTED.

Source: SDR CNMA200600002
ELECT. POWER LOSS-50 PC; WARNING INDICATION · 2006-02-23 Matched by certificate designator
ATA 2432

Part: CHARGER — INOPERATIVE (MASTER BATTERY) · airframe 114,016 hrs · 23,229 cycles

DURING CLIMBOUT BATTERY VOLTAGE READ 0 WITH NO CLOCKS. BATTERY CHARGER RELAY RESET 2 TIMES IN-FLIGHT WITH BATTERY VOLTAGE NORMAL AND CLOCKS RETURNED. CHARGER FAILED AGAIN, BATTERY VOLTAGE 0 FOR REMAINDER OF FLIGHT WITH NO CLOCKS. ALL OTHER INDICATIONS NORMAL. REMOVED AND REPLACED BOTH A/C BATTERIES IAW 24-34-01 AND BATTERY CHARGER AS WELL AS THE BATTERY CHARGER RELAY PERFORMED BATTERY CHARGER TEST IAW 24-34, NO DEFECT NOTED.

Source: SDR CNMA2006002
Earlier reports · 1998–2005 · 24 reports

2005

FLUID LOSS; WARNING INDICATION · 2005-08-31 Matched by certificate designator
ATA 2810

Part: VALVE — MALFUNCTIONED (FUEL SYSTEM) · airframe 112,884 hrs · 22,986 cycles

FUEL VENTING OUT OF THE LEFT WING VENT BOX AREA. RIGHT SIDE OK. NO TANK OVERFILLED LIGHT ON. APPROX 1600 LBS VENTED. AFTER BLOCK IN FUEL LEAKING OUT OF LEFT FUEL VENT BOX DRAIN. REMOVED AND REPLACED CLIMB VENT FLOAT VLV IAW DC10 M/M 28-12. ALSO REMOVED AND REPLACED VENT BOX CK VLV PRECAUTIONARY PER 28-12.

Source: SDR 2005000015
FLUID LOSS; WARNING INDICATION · 2005-08-31 Matched by certificate designator
ATA 2810

Part: CHECK VALVE — LEAKING (FUEL VENT) · airframe 112,884 hrs · 22,986 cycles

FUEL VENTING OUT OF THE LEFT WING VENT BOX AREA. RIGHT SIDE OK. NO TANK OVERFILLED LT ON. APPROX 1600 LBS VENTED. AFTER BLOCK IN FUEL LEAKING OUT OF LEFT FUEL VENT BOX DRAIN. REMOVED AND REPLACED CLIMB VENT FLOAT VALVE IAW DC10 M/M 28-12. ALSO REMOVED AND REPLACED VENT BOX CHECK VALVE PRECAUTIONARY PER 28-12.

Source: SDR CNMA200500015
FLUID LOSS · 2005-08-29 Matched by certificate designator
ATA 2810

Part: CHECK VALVE — MALFUNCTIONED (FUEL SYSTEM) · airframe 112,882 hrs · 22,985 cycles

AFTER T/O, RECEIVED TANK OVERFILLED LIGHT ON. VISUAL CHECK CONFIRMED FUEL VENTING OUT OF THE LEFT WING VENT. FUEL VENTED FOR APPROX 20 MIN. FUEL LOSS CONFIRMED OUT OF NR 3 MAIN AT 2000 LBS. TRIED TAKING TANKS DOWN TO 3000 LBS BELOW FULL AND REFILLING THEM USING THEIR ASSOC TRANS PUMPS. NO HELP. FUEL FINALLY STOPPED VENTING ON APPROACH. REMOVED AND REPLACED FUEL VENT CHECK VALVE IAW DC 10 M/M 28-12. LEAK CHECK GOOD.

Source: SDR 2005000014
FLUID LOSS; WARNING INDICATION · 2005-08-29 Matched by certificate designator
ATA 2810

Part: CHECK VALVE — MALFUNCTIONED (FUEL VENT) · airframe 112,882 hrs · 22,985 cycles

AFTER T/O, GOT THE TANK OVERFILLED LEFT ON. VISUAL CHECK CONFIRMED FUEL VENTING OUT OF THE LEFT WING VENT. FUEL VENTED FOR APPROX 20 MIN. FUEL LOSS CONFIRMED OUT OF NR 3 MAIN AT 2000 LBS. TRIED TAKING TANKS DOWN TO 3000 LBS BELOW FULL AND REFILLING THEM USING ASSOC TRANS PUMPS. NO HELP, FUEL FINALLY STOPPED VENTING ON APPROACH. REMOVED AND REPLACED FUEL VENT CHECK VALVE IAW DC 10 M/M 28-12. LEAK CHECK GOOD.

Source: SDR CNMA2005014
FLUID LOSS · 2005-08-29 Matched by certificate designator
ATA 2810

Part: CHECK VALVE — LEAKING (FUEL VENT) · airframe 112,882 hrs · 22,985 cycles

AFTER T/O, GOT THE TANK OVERFILLED LT ON. VISUAL CHECK CONFIRMED FUEL VENTING OUT OF THE LEFT WING VENT. FUEL VENTED FOR APPROX 20 MIN. FUEL LOSS CONFIRMED OUT OF NR 3 MAIN AT 2000 LBS. TRIED TAKING TANKS DOWN TO 3000 LBS BELOW FULL AND REFILLING THEM USING ASSOC TRANS PUMPS. NO HELP, FUEL FINALLY STOPPED VENTING ON APPROACH. REMOVED AND REPLACED FUEL VENT CHECK VALVE IAW DC 10 M/M 28-12. LEAK CHECK GOOD.

Source: SDR CNMA200500014

2004

INFLIGHT SEPARATION · 2004-11-24 Matched by certificate designator
ATA 5410

Part: COWLING — DEPARTED (NR 3 ENGINE) · airframe 111,139 hrs · 22,622 cycles

AT CLIMB-OUT, NR 3 ENG LOST ENGINE COWLING DUMPED FUEL RETURNED TO EDDF.

Source: SDR 2004000015
PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2004-06-13 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 1) · airframe 110,287 hrs · 22,454 cycles

ON T/O ROLL, NR 1 ENGINE MADE LOUD BANG, ENGINE FAIL LIGHT ILLUMINATED AND EGT PEGGED. N1 WAS 130 PERCENT AND SPEED WAS 125 KIAS. T/O ABORTED. TOWER NOTED FIRE FROM INTAKE.

Source: SDR 2004000007
FLUID LOSS · 2004-03-09 Matched by certificate designator
ATA 7261

Part: SEAL — LEAKING (NR 2 ENGINE) · airframe 109,547 hrs · 22,313 cycles

NR 2 ENGINE OIL QUANITY STEADILY DECREASED DURING CRUISE. LOST 2.5 QTS IN 50 MINUTES. SHUTDOWN ENGINE TO PRESERVE OIL QTY. RESTARTED ENGINE AT ALT. FL 240, QTY HELD OK FOR APPROACH AND LANDING. FROM PREVIOUS ENGINE DRIVEN HYD PUMP REMOVAL AND BLOCKOUT FOUND SPLINE LOCKOUT TOOL SEAL DAMAGED. REPLACED SEAL LEAK CHECK GOOD

Source: SDR 2004000001

2003

FLT CONT AFFECTED · 2003-12-17 Matched by certificate designator
ATA 2720

Part: RUDDER — STUCK (TAIL) · airframe 108,838 hrs · 22,171 cycles

ON SHORT FINAL AND FLARE RUDDER PEDALS COULD NOT BE MOVED. RUDDER PEDALS COULD NOT BE MOVED ON TAXI IN. TILLER OPERATION NORMAL. CAPTAINS AND CO-PILOTS SAME. LIMITED TRAVEL AT GATE. TAXI CHECK OF RUDDER PEDALS NORMAL. F/O DID NOTICE ALOT OF RUDDER FORCE ON TAKEOFF WITH SYMETRICAL THRUST AND NO CROSSWIND.

Source: SDR CNMA200300011
OVER TEMP; WARNING INDICATION · 2003-12-10 Matched by certificate designator
ATA 7200

Part: ENGINE — OVERTEMP (NR 1) · airframe 108,765 hrs · 22,158 cycles

ON INITIAL CLIMBOUT NR 1 ENGINE OIL TEMP CLIMBED TO AND EXCEEDED LIMITS. (PEGGED OUT) SHUT DOWN ENGINE.

Source: SDR CNMA200300008
OTHER · 2003-01-17 Matched by certificate designator
ATA 2565

Part: SLIDE — DISLODGED (CABIN) · airframe 106,088 hrs · 21,681 cycles

WHILE AT GATE FLIGHT ATTENDANT OPENED R-1 DOOR WITHOUT DISARMING DOOR. SLIDE CAME OUT OF ITS CONTAINER AND LANDED ON TOP OF CATERING TRUCK AWAITING TO DELIVER. APPARENTLY SLIDE DID NOT FALL FAR ENOUGH TO ACTIVATE DEPLOYMENT MECHANISM. SLIDE WAS REMOVED AND REPLACED, SLIDE BEING SENT IN TO CHECK AND OVERHAUL. (P)

Source: SDR CNMA200300001

2002

WARNING INDICATION · 2002-12-20 Matched by certificate designator
ATA 3260

Part: ELECTRICAL BOX · airframe 105,889 hrs · 21,637 cycles

Overspeed warning sounded at 270 knots - slats confirmed retracted. Removed and replaced Proximity Electronic Unit. Bite test normal.

Source: SDR CNMA200200007

2001

OTHER · 2001-08-15 Matched by certificate designator
ATA 5411

Part: SPAR — CRACKED (NR 3 PYLON) · airframe 105,146 hrs · 21,500 cycles

INSPECTION FOUND A 2 INCH CRACK IN NR 3 PYLON LOWER SPAR WEB AT FAN DUCT CUTOUT. A REPAIR ANGLE AND STIFFENER WERE INSTALLED IAW SRM 54-20-00, FIGURE 19A.

Source: SDR CALA0100762

2000

OTHER · 2000-08-10 Unresolved
ATA 2841

Part: HARNESS — CHAFED (FUEL TANK NR 3)

D-CHECK, FQI SYSTEM WIRING CHAFING AND ARCING INSIDE FUEL TANK NR 3, PROBE NR 6, HARNESS FOUND CHAFING ON MOUNT BRACKET OF THE FILL ALOT VALVE IN BAY R07 (XORS- -298-500). WIRES 3E900E22GR X 3E901E22WH DAMAGED THROUGH OUTER SLEEVE INSULATION CAUSING ARCING ON BRACKET. HARNESS WAS EXCESSIVELY SLACK. HARNESS ANP0138-502 REPLACED IAW WDM28-41-08 FRM PROBE 6(T2-104) TO JUNC PROBE 2 (T2-102). PERFORMED STATIC BEND TESTS ON ALL BOOST PUMPS, DC START PUMPS, FEED SYS DUCTS, REFUEL DUCTS, VENT SYS, OVER 100 READINGS GREATER THAN 100 MILLIOHMS ACROSS ALL 3 MAIN TANKS AND AUX TANKS. THE NECESSARY ACTION WAS TAKEN (REBONDING). (X)

Source: SDR 20000810SH021
OTHER · 2000-07-28 Unresolved
ATA 2841

Part: HARNESS — CHAFED (FUEL TANK)

D-CHECK, FQI SYSTEM WIRING CHAFING AND ARCING INSIDE FUEL TANK NR 3, PROBE NR 6. HARNESS FOUND CHAFING ON MOUNT BRACKET OF THE FILL PILOT VALVE IN BAY R07 (XORS: -298-500). WIRES 3E900E22GR X 3E901E22WH DAMAGED THROUGH OUTER SLEEVE INSULATION CAUSING ARCING ON BRACKET. HARNESS WAS EXCESSIVELY SLACK. HARNESS ANPO138-502 REPLACED IAW WDM28-41-08 FROM PROBE 6 (T2-104) TO JUNC PROBE 2 (T2-102). PERFORMED STATIC BOND TESTS ON ALL BOOST PUMPS, DC START PUMPS, FEED SYS DUCTS, RE-FUEL DUCTS, VENT SYS. OVER 100 READINGS GREATER THAN 100 MILLIOHMS ACROSS ALL 3 MAIN TANKS AND AUXILIARY TANKS. THE NECESSARY ACTION WAS TAKEN (RE-BONDING). (X)

Source: SDR 20000829SH007
OTHER · 2000-07-26 Matched by certificate designator
ATA 2840

Part: HARNESS — FRAYED (RT WING) · airframe 101,637 hrs · 20,878 cycles

INSPECTION FOUND RT WING FUEL TANK WIRING OUTER AND INNER INSULATION CHAFING AND ARCING DAMAGE ON FLOAT SWITCH BRACKET ZONE R07-11, LOCATION T2-104, PROBE XORS = 298.500. ALSO FOUND RT WING FUEL TANK WIRING FRAYED AND INNER FERRULE AT TANK PROBE T2-105, ZONE R08, XORS 298.500. BOTH WIRING HARNESSES WERE REPLACED AND FUEL QUANTITY CHECK WAS SATISFACTORY IAW MM 28-41-00. THE ARCING DAMAGE FOUND ON RT WING PILOT VALVE MOUNTING BRACKET WAS BLENDED OUT IAW SRM 57-00-01 AND REPROTECTED IAW SRM 51-20-01.

Source: SDR CALA0001384

1999

OTHER · 1999-10-10 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1887)

FLOORBEAM J SECTION CORRODED AT ST 1887 AT 60R - 90R. REMOVED CORROSION. FABRICATED AND INSTALLED NEW SECTION PER SRM 51-21-00 AND GMM 10-900-01.

Source: SDR CALA9901353
OTHER · 1999-10-10 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1887)

FLOORBEAM J SECTION AT STA 1887 AT 60L - 90L CORRODED. REMOVED CORRODED AREA. FABRICATED AND INSTALLED NEW SECTION PER SRM 51-21-00 AND GMM 10-900-01.

Source: SDR CALA9901354
OTHER · 1999-10-10 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1887)

FLOORBEAM J SECTION AT STN 1887 AT 27R - 33R CORRODED. REMOVED CORRODED AREA. FABRICATED AND INSTALLED NEW SECTION PER SRM 51-21-00 AND GMM 10-900-01.

Source: SDR CALA9901355
OTHER · 1999-10-10 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1887)

FLOOR BEAM J SECTION CORRODED AT ST 1887 AT 39L TO 58 L. REMOVED CORROSION AND INSTALLED NEW SECTION PER SRM 51-21-00 AND GMM 10-900-01.

Source: SDR CALA9901352
SMOKE/FUMES/ODORS/SPARKS · 1999-07-28 Matched by certificate designator
ATA 2340

Part: DECODER — SHORTED (ROW 37&38KL)

SMOKE APPEARED IN THE AIRCRAFT CABIN NEAR THE VICINITY OF SEATS 37 AND 38KL WHILE ON FINAL APPROACH TO DUS. THE FLIGHT ATTENDANT'S PULLED OVERHEAD PANEL IN THE AREA AND USED HALON TO COOL THE AREA. NO FIRE WAS OBSERVED. THE AIRCRAFT LANDED AT DUS WITHOUT INCIDENT. THE FAULT WAS TRACED TO OVERHEATED TIMER/DECODER ABOVE SEATS 37 AND 38KL. THE TIMER/DECODER WAS REMOVED AND REPLACED. NO WIRING DAMAGE WAS FOUND. IN ADDITION, THE HALON FIRE EXTINGUISHER WAS REPLACED.

Source: SDR CALA9900878

1998

NO TEST · 1998-06-18 Matched by certificate designator
ATA 3350

Part: BATTERY CHARGER — INOPERATIVE (CABIN)

INSPECTION FOUND THE EMERGENCY AISLE LIGHTING INOPERATIVE AT ROWS 9 AND 10 (LEFT AND RIGHT). THE BATTERY CHARGER AT DOOR 2R AND 2L GALLEY OVERHEAD PANEL WAS REPLACED AND THE EMERGENCY LIGHT BATTERY PACK WAS CHARGED. OPERATIONAL CHECKS WERE GOOD IAW MM 33-50-00.

Source: SDR CALA9801129
OTHER · 1998-03-23 Matched by certificate designator
ATA 2565

Part: SLIDE — INOPERATIVE (R-3 DOOR)

INSPECTION FOUND THE R-3 DOOR SLIDE BOTTLE PRESSURE LIGHT ILLUMINATED. THE R-3 DOOR SLIDE WAS REMOVED AND REPLACED AND THE LIGHT TESTED NORMAL.

Source: SDR CALA9800537
FALSE WARNING · 1998-02-10 Matched by certificate designator
ATA 2612

Part: FIRE DETECTOR — CHAFED (NR 2 ENGINE)

THE NR 2 ENGINE A FIRE LOOP DETECTOR LIGHT BEGAN TO FLICKER WHILE IN CRUISE FLIGHT FROM LGW TO EWR. WHEN THE NR 2 ENGINE THRUST WAS REDUCED THE FLICKERING STOPPED. WHEN THRUST WAS ADDED THE FLICKERING RESUMED. THE NR 2 ENGINE WAS OPERATED WITH PARTIAL THRUST, FUEL WAS DUMPED, AND THE AIRCRAFT WAS RETURNED TO LGW WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND BROKEN CLAMPS AND LOOPS A AND B WERE CHAFING. THE NR 2 ENGINE LOWER CORE DETECTOR ASSEMBLY WAS REMOVED AND REPLACED. THE NR 2 ENGINE FIRE DETECTION SYSTEM CHECKED GOOD.

Source: SDR CALA9800206