N606FR
Registered owner: BANK OF UTAH TRUSTEE, UT (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
ACFT WAS ON SCHEDULED MAINTENANCE REFERENCE LP477858 #3 EPSU 10WL TEST FAIL BATTERY FAULT. REMOVED AND REPLACED EPSU BATTERY AT 10WL REF AMM 33-51-38-400-002-A. A/C OK FOR SERVICE. /END/.
ACFT WAS ON SCHEDULED MAINTENANCE REFERENCE LP477859 #1 EPSU 13WL TEST FAIL BATTERY FAULT. REMOVED AND REPLACED EPSU BATTERY AT 13WL REF AMM 33-51-38-400-002-A. A/C OK FOR SERVICE.
ACFT WAS ON SCHEDULED MAINTENANCE REFERENCE LP477859 #2 EPSU 16WL TEST FAIL BATTERY FAULT. REMOVED AND REPLACED EPSU BATTERY AT 16WL REF AMM 33-51-38-400-002-A. A/C OK FOR SERVICE.
AC WAS NOT OUT OF SERVICE DUE TO THIS EVENT, REFERENCE LP275823 ITEM #2 DURING HEAVY CHECK EPSU BATTERY 16WL OWD R, FAILED TEST. AIRCRAFT REMOVED FROM SERVICE. CORRECTIVE ACTION: LP275823 ITEM # 2 REMOVED AND REPLACED EPSU BATTERY 16WL, OWD R IAW AMM 33-51-38-000-002-A/400-002-A OPS CHECK GOOD. /END/.
ACFT WAS NOT OUT OF SERVICE DUE TO THIS EVENT REFERENCE LP275823 ITEM NR 1, DURING HEAVY CHECK EPSU BATTERY 11WL EXIT L, FAILED TEST. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED EPSU BATTERY 11WL, EXIT L IAW AMM 33-51-38-000-002-A/400-002-A. OPS TEST GOOD.
ACFT WAS NOT OUT OF SERVICE DUE TO THIS EVENT REFERENCE LP275822 ITEM NR 3. DURING HEAVY CHECK EPSU BATTERY 10WL FWD L, FAILED TEST. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE EPSU BATTERY 10WL, FWD LT IAW AMM 33-51-38-000-002-A/400-002-A OPS CHECK GOOD.