N615CK

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
CROMAN CORP (JYEA)Certificate holderMatched by certificate designator
CROMAN CORP (JYEA)Operator2022-02-22 – 2022-02-22Operator named in NTSB report

Accident & incident history

Acc · 2022-02-22 Operator named in NTSB report
SIKORSKY S-61N Fatal injury Part 133CROMAN CORP
Source: NTSB case ANC22FA018

Maintenance disclosures

J · 2015-05-13 Matched by certificate designator
ATA 2930

WHEN TESTING HYD SYS USING MOGEN AND SELECTING PRIMARY OFF, IT WOULD NOT. AFTER THE THIRD SELECTION TO OFF, IT FINALLY TURNED OFF SECURING PRESSURE TO PRIMARY WITH A CAUTION LIGHT ILLUMINATED. FURTHER CHECKS OF THE INTERLOCK SYSTEM WERE NORMAL. ON THE PREVIOUS FLIGHT 12 MAY, 2015 AUX HYDRAULICS WERE SECURED ON SHORT FINAL, SIMULATING AN INFLIGHT SYSTEM FAILURE, NOT ACTUAL, AND AT THIS TIME ON SHORT FINAL THE PRIMARY SYSTEM STARTED CYCLING ON AND OFF CAUSING BUFFETING AND VIBRATIONS IN THE CYCLIC CONTROL. AUX HYDRAULICS WERE IMMEDIATELY RESTORED AND AN UNEVENTFUL LANDING PERFORMED. UPON REACHING PARKING AND MAINTENANCE CHECKS PERFORMED ALL SYSTEMS OPERATED NORMAL. ON 13 MAY, 2015 AFTER FURTHER TROUBLESHOOTING MAINTENANCE TECHS ISOLATED THE FAULT TO BE THE PRIMARY HYDRAULICS PRESSURE SWITCH. REPLACEMENT WITH AN O/H UNIT RETURNED THE SYSTEMS TO NORMAL OPERATION.

Source: SDR JYEA2015FA0000211 · FAA SDRS