N61ZZ
Registered owner: VALIAIR LC TRUSTEE, WY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
1 report on file, 2006-02-08.
Part: VALVE — FAILED (COCKPIT)
THIS AIRCRAFT WAS ENROUTE. THE PIC NOTICED AN AIR DISTRIBUTION DUCT OVERHEAT LIGHT ON IN THE COCKPIT. THE FLIGHT CREW ELECTED TO DIVERT FOR FURTHER INVESTIGATION AND TROUBLESHOOTING. MAINTENANCE REMOVED AND REPLACED THE COCKPIT TEMPERATURE SENSOR FAN, COCKPIT TEMPERATURE CONTROL VALVE AND COCKPIT TEMPERATURE CONTROL TORQUE MOTOR IAW MM. OPERATION CHECK FOUND SATISFACTORY. (K)