N622UP
Registered owner: UNITED PARCEL SERVICE CO, KY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
5 reports on file, 2020-11-05 – 2024-08-09.
Part: SNUBBER — OUT OF LIMITS (ZONE 800) · airframe 15,846 hrs · 2,369 cycles
*** SDR FILED OPEN *** FAULT - FOUND MAIN ENTRY DOOR ROTARY SNUBBER PIN EXTENSION IS WITHOUT THE MINIMUM LIMIT. (REPLACE) FAULT APPROVED PER GMM-MTX 09.05.01.05.
Part: SNUBBER — INOPERATIVE (ZONE 800) · airframe 15,846 hrs · 2,369 cycles
FOUND MAIN ENTRY DOOR ROTARY SNUBBER PIN EXTENSION IS WITHOUT THE MINIMUM LIMIT. (REPLACE). I.A.W AMM TASK 52-11-10-000-801 REV. 45 AND AMM TASK 52-11-10-400-801 REV. 45 REPLACE MAIN ENTRY DOOR ROTARY SUNBBER AND OPREACTION CHECK NORMAL.
Part: DOOR — JAMMED (L1) · airframe 13,892 hrs · 2,093 cycles
L1 DOOR JAMMED ON CREW STAIRS DURING UNLOAD PERFORMED GROUND HANDLING EQUIPMENT HITS THE AIRPLANE CONDITIONAL INSPECTION PER AMM 05-51-59. NO DAMAGE NOTED, OK FOR SERVICE
Part: OXYGEN MASK — DAMAGED (COCKPIT) · airframe 12,029 hrs · 1,826 cycles
CAPTAINS O2 MASK QUICK DON MASK RED LEVER MISSING R AND R CAPTAINS O2 MASK REF AMM 35-11-18
Part: HOSE — DISCONNECTED (NR 2 PACK MIXER) · airframe 641 hrs · 109 cycles
INSPECTION TYPE: NA ATB. SDR FILED OPEN. PAN PAN WAS DECLARED BUT CANCELLED, LANDING UNEVENTFUL, NO EMERGENCY EQUIPMENT USED. CRUISE ALT FL370 CABIN ALT INCREASING OUTFLOW VALVES BOTH CLOSED. CHANGED CABIN ALT. CONTROLLER FROM BOTH TO A. CABIN ALT CONTINUED CLIMBING. AT CABIN ALT 1000 MASTER/CAUTION WARNING EMERGENCY DESCENT TO F250. CABIN ALT REDUCED PASSING FL280. T/S FWD CRG OVBD DEFCK FOUND HOSE DISCONNECTED PARTLY AT PACK 2 MIXER, PORT AT RECIRC FAN, PER AMM 21-51-44. REINSTALLED HOSE, PER AMM 21-51-00. DO CMC TEST OF PACK, PASS, PER MEL 21-26-1-2. REACTIVATE FWD OVRBRD VALVE. DO AMM 05-51-08 EXCESS CABIN PRESS LEAK TEST DELTA P PROP 4.0 TO 3.1, PER MEL 21-26-1-2 REV DMP. PER AMM 21-26-00 LOWER FWD CARGO OVBRD EXH SYSTEM TEST, PASS. CLOSED M725078.