N62896

BOEING 737-900ER · 2016 · Fixed-wing multi-engine · 2 engines · 222 seats · Valid Registration

Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

17 reports on file, 2016-11-15 – 2026-10-27.

SMOKE/FUMES/ODORS/SPARKS · 2026-10-27 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 30,141 hrs · 11,336 cycles

BAD ODOR IN CABIN DURING THE DESCENT FROM AIR CONDITIONING COMPLIED WITH FIM 21-00 TASK 806. NO ODOR NOTED FROM FLIGHT CREW. CABIN CREW NOTICED THE ODOR FOR 5 TO 10 MINS ON APPROACH, 20 TO 30 MINS FROM LANDING. NO ODOR OF ELECTRICAL OR SMOKED REPORTED. INSPECTED NR 1 & 2 ENG, NO DISCREPANCIES FOUND. INSPECTED INLET AND OUTLET OF NR 1 & 2 PACK, BOTH INSPECTED GOOD FOR FLIGHT. NO PREVIOUS HISTORY OF ODORS. AIRCRAFT GOOD FOR SERVICE.

Source: SDR CALA2026102820617
NO TEST · 2026-10-08 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (ZONE 200) · airframe 30,010 hrs · 11,275 cycles

FOUND L1 EXTERIOR SLIDE LIGHT INOPERATIVE, DURING A SERVICE CHECK. R & R L1 EXTERIOR EMERGENCY SLIDE LAMP IAW AMM 33-51-04-960-801. FOUND EMER BATTERY NOT HOLDING A CHARGE. R & R THE FWD OVERHEAD EMERGENCY BATTERY IAW AMM 33-51-06-960-805. OP CHECKED GOOD.

Source: SDR CALA2026100920241
SMOKE/FUMES/ODORS/SPARKS · 2026-04-08 Matched by certificate designator
ATA 7200

Part: ENGINE — ODOR · airframe 28,801 hrs · 10,734 cycles

RETURNED TO GATE FOR ODER AFTER STARTING NR 1 ENGINE. SUSPECT ODOR CAUSED BY ENGINE WASH PERFORMED THE PREVIOUS NIGHT. PILOTS REPORTED SMELLING ODOR WITH BOTH ENGINES RUNNING AT 40% N1. PERFORMED CONDITIONAL INSPECTION FOR ODOR PER AMM 05-51-26-800-801-C1. RAN BOTH ENGINES AT IDLE. AFTER TURNING ON ALL BLEED SOURCES AN OILY SMELL WAS PRESENT FOR APPROX 30 SECONDS THEN DISAPPEARED. PERFORMED OIL CONTAMINATION REMOVAL FROM PNEUMATIC SYSTEMS PER AMM 21-00-01-100-801. ACCOMPANIED PILOTS FOR MX TAXI AND DURING HIGH POWER RUN FOUND ALL ODORS TO DISSIPATE. RECIRCULAT.

Source: SDR CALA2026040915225
Earlier reports · 2016–2025 · 14 reports

2025

SMOKE/FUMES/ODORS/SPARKS · 2025-11-22 Matched by certificate designator
ATA 3460

Part: MODULE — ODOR (ZONE 200) · airframe 27,776 hrs · 10,316 cycles

CREW REPORTED STRONG PLASTIC ODOR EMINATING FROM FLOOR AREA BY RUDDER PEDALS AND FWD AVIONICS COMPARTMENT; UNABLE TO PINPOINT ODOR AT THIS TIME BUT SUSPECT STARTING WITH WEATHER/RADAR UNIT LOCATED AT FWD AVIONICS COMPARTMENT. REFERENCE TASK 05-51-26-800-801-C1, DEBRIEFED CREW AND REPORT CREATED AND SPOKE TO TOM C, AND COMPLETED STEPS UP TO ITEMS 1B6B, NEED TO CONTINUE FROM 1C. CONTINUED FROM 1C TO C.1.B.2.A NO DEFECTS NOTED , FURTHER T/S NEEDS TO BE CONTINUED REF AMM 05-51-26-800-801-C1. NOTE... SEE LOG 7036556 ALSO UPDATED FOR GROUND TIME PERFORMED GVI AND PHYSICALLY CHECKED WIRES AND GROUNDS IN FWD EE BAY IMMEDIATELY AFT OF RADOME FOCUSING ON AREA SURROUNDING WEATHER TRANSCEIVER IRT AMM 05-51-26-800-801-C1 STEP C,1, E, F NO VISUAL EVIDENCE OF BURNING OR ARCING. REQUIRES FURTHER T/S IN RADOME AND FWD EE BAY TO LOCATE SOURCE OF SMELL. OPS CHECKED WXR IRT 34-43-00-710-802-001. OPS CHECK GOOD BUT SMELL PERSISTS. ISOLATED "BURNT ELECTRICAL" SMELL COMING FROM AURAL WARNING MODULE (REF MM-31-51-04) SEE L/P 7047595 FOR REMOVAL OF AURAL WARNING MODULE ODOR IN FLIGHT DECK WAS FOUND TO BE EMANATING FROM AURAL WARNING MODULE. ODOR IS NO LONGER PRESENT.

Source: SDR CALA2025112511447
OTHER · 2025-11-14 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 27,712 hrs · 10,293 cycles

RED EMERGENCY LIGHT INOPERATIVE ON SEAT 21ABC. REPLACED FLOOR PROXIMITY LIGHT ASSEMBLY ON SEAT 21ABC. OPS CHECK GOOD IAW 33-51-11.

Source: SDR CALA2025111711233
OTHER · 2025-10-26 Matched by certificate designator
ATA 5240

Part: DOOR — NO DISCREPANCY (ZONE 800) · airframe 27,575 hrs · 10,235 cycles

FA REPORTS DOOR 2R KEEPS MOVING UP INFLT PRESSURERIZATION WAS NORMAL. PERFORMED GVI OF DOOR 2R ROLLER CAMS, LATCH ROLLERS AND DOOR INDICATION SENSOR FOR WITNESS MARKS OR CONTACT WEAR. NO DEFECTS FOUND. REF FIM 52-10 TASK 815. DOOR OPENS AND CLOSES NORMALLY, INIDICATIONS WERE NORMAL. NO DEFECTS FOUND. NO HISTORY WITHIN LAST 10 DAYS.

Source: SDR CALA2025103010719
OTHER · 2025-06-25 Matched by certificate designator
ATA 2565

Part: SLIDE — NO DISCREPANCY (ZONE 800) · airframe 27,025 hrs · 10,013 cycles

DOOR 1R SLIDE HAS YELLOW RAFT MATERIAL PROTRUDING FROM BOTTOM. NO DEFECTS NOTED REFERENCE AMM 25-66-00.

Source: SDR CALA2025062705980
OTHER · 2025-05-17 Matched by certificate designator
ATA 2565

Part: SLIDE — EXPOSED (ZONE 800) · airframe 26,652 hrs · 9,874 cycles

XCESSIVE SLIDE PACK MATERIAL SHOWING 2L 1R. VERTIFY AND INSPECT SLIDES AND GIRTH BAR IS SECURRED

Source: SDR CALA2025052004833

2024

OTHER · 2024-11-17 Matched by certificate designator
ATA 2560

Part: SKIRT — OUT OF ADJUST (GIRT BAR) · airframe 25,147 hrs · 9,285 cycles

GIRT BAR WILL NOT SEAT PROPERLY IN THE FWD LEFT FLOOR ATTACHMENT POINTS ADJUSTED SKIRT ON FWD DOOR L1. OPS CKS OK.

Source: SDR CALA2024112001205

2021

WARNING INDICATION · 2021-11-11 Matched by certificate designator
ATA 2911

Part: NONE — FAILED (#1 ENG) · airframe 15,463 hrs · 5,630 cycles

A-HYD QUANTITY DROP FROM 99PERCENT TO PRESENT 21 PERCENT W/2970 PRESS MET ACFT HYD FLUID LEAKING FROM #1 ENGINE FOUND ENGINE DRIVEN PUMP LEAKING PN INSTALLED 29-2910-9-0003 IS NIS EWR REF L/P 7412438 FOR ENG 1 HYDRAULIC PUMP REPLACEMENT PER AVO9276 AND ECRA# 7900-01439.

Source: SDR CALA2021111102094

2019

SMOKE/FUMES/ODORS/SPARKS · 2019-03-24 Matched by certificate designator
ATA 2510

Part: ADAPTER — OVERHEATED (COCKPIT) · airframe 8,230 hrs · 2,982 cycles

BURNING ELECTRIC SMELL FROM FD USB ADAPTOR WITH BOTH IPADS PLUGGED IN. CAPTAINS IPAD NOW INOP. DEBRIEFED CREW AND EVALUATED SMOKE QUESTIONNAIRE. DETERMINED ODOR DUE TO OVERHEATED DC IPAD ADAPTER. NO FURTHER ACTION REQUIRED PER AMM 05-51-26-800-801C1.

Source: SDR CALA2019032500466

2018

OTHER · 2018-02-02 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (CABIN) · airframe 4,251 hrs · 1,543 cycles

EMERGENCY LIGHTING LENS COVER IS MISSING AT AFT SIDE OF COAT CLOSET JUST FORWARD OF SEAT 1,B. REPLACED LENS COVER ON EMERGENCY LIGHT AT AFT SIDE OF COAT CLOSET.

Source: SDR CALA2018020200457

2017

OTHER · 2017-11-25 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (CABIN) · airframe 3,612 hrs · 1,317 cycles

FWD COAT CLOSET AFT EMER EXIT LIGHT MISSING LENS COVER. REPLACED FWD COAT CLOSET AFT EMERGENCY LIGHT LENS COVER. OPS CHECKED EMERGENCY LIGHTS.

Source: SDR CALA2017112504215
OTHER · 2017-09-22 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (EMERGENCY LIGHT) · airframe 3,048 hrs · 1,087 cycles

EMERGENCY LIGHT BY THE L1 DOOR IS MISSING THE AFT LENS. REPLACED THE LENS.

Source: SDR CALA2017092203297
OTHER · 2017-07-17 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE (CABIN) · airframe 2,480 hrs · 860 cycles

FLASHLIGHT DOES NOT TURN ON 122 LOCATION 2R. REPLACED EMERGENCY FLASHLIGHT AND BASE AT DOOR 2R.

Source: SDR CALA2017071702275

2016

FALSE WARNING · 2016-11-26 Matched by certificate designator
ATA 2613

Part: CONTROL UNIT — FAULTY (E&E BAY) · airframe 110 hrs · 33 cycles

WHEEL WELL FIRE INDICATION ON FINAL. OCCURRED WHEN FLAPS PLACED TO 5. REMAINED ON THROUGH LANDING FOUND FAULT CODE 84 ON CTRL UNIT, PER FIM26-18-00-810-802 VOLTAGE CHECKS & RESISTANCE CHECKS GOOD. CODE WOULD NOT RESET. RPL OVERHEAT CTRL UNIT REF MM 26-18-01. SYSTEM TEST GOOD & CODE CLEARED.

Source: SDR CALA2016112600974
OTHER · 2016-11-15 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 9 hrs · 3 cycles

AFT RT EXIT EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06.

Source: SDR CALA2016111800923