N645DL

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

22 reports on file, 1995-01-16 – 2012-10-31.

NO TEST · 2012-10-31 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 80,139 hrs · 35,097 cycles

MX DISCOVERED MID CABIN EMERGENCY EXIT SIGN HAS NUMEROUS LAMPS INOPERATIVE. REPLACED LAMPS, OPS NORMAL.

Source: SDR DALA1253550645
Earlier reports · 1995–2010 · 21 reports

2010

SMOKE/FUMES/ODORS/SPARKS · 2010-06-29 Matched by certificate designator
ATA 3425

Part: DISPLAY — MALFUNCTIONED (COCKPIT) · airframe 72,366 hrs · 32,328 cycles

DURING FLIGHT, AN ELECTRICAL BURNING SMELL WAS EXPERIENCED IN THE COCKPIT ALONG WITH LEFT HSI FAILURE. MAINTENANCE REPLACED THE LEFT HSI DISPLAY UNIT. OPERATIONAL CHECK WAS GOOD.

Source: SDR DALA1015200645

2009

FLT CONT AFFECTED · 2009-05-28 Matched by certificate designator
ATA 2750

Part: TRANSMISSION — MALFUNCTIONED (RT WING TE FLAPS) · airframe 68,565 hrs · 31,091 cycles

UPON SELECTING FLAPS 20, BECAME STUCK BETWEEN 15 AND 20 AND TE FLAP DISAGREE EICAS MSG APPEARED EXECUTED PROC WITH TE FLAP DISAGREE AND FLAPS 26. PERFORMED FSEU BITE NTF INSP FLAP TRANSMISSION, FOUND RT W/W SIDEWAYS TRANSMISSION OVERLOAD INDICATOR POPPED. RESET INDICATOR AND SERVICED TRANSMISSION IAW AMM RAN FLAPS SEVERAL TIMES CKS GOOD IAW AMM.

Source: SDR DL757090935

2008

SMOKE/FUMES/ODORS/SPARKS · 2008-09-02 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 66,167 hrs · 30,246 cycles

AT 40K FEET FLT NOTIFIED FLT CREW OF RUBBERY/SULFUR ODOR AROUND ROWS 23-27 IN PASSENGER CABIN. THE ODOR WAS EMANATING FROM THE FLOOR AREA. CREW DECIDED TO DIVERT TO IAD, DECLARED AN EMERGENCY. AT APPROX 20K FT ODOR WAS DISSIPATING, ON LANDING ODOR WAS GONE. INSPECTED A/C INCLUDING ENG 1 AND INSPECTED LT AND RT PACK BAY, APU AND BOTH PACKS FOR 90 MINUTES, RECIRC FAN AREA. INSPECTED PAX CA ELECTRONIC BOXES. INSPECTED OVHD PSUS IN AFFECTED AREA. NO TROUBLE.

Source: SDR DL757081138

2007

NO TEST · 2007-12-01 Matched by certificate designator
ATA 2597

Part: WIRE HARNESS — BROKEN (RT OVRWG SLIDE) · airframe 63,904 hrs · 29,505 cycles

RIGHT OVERWING SLIDE DID NOT DEPLOY DURING SAMPLING EVENT. TROUBLESHOT PER WD 25-65-21. FOUND WIRE HARNESS W0624 ON P79 PANEL TIED TOO TIGHT CAUSING WIRE COMING FROM RELAY BASE K10536 TO BE VERY TAUGHT. THIS CAUSED WIRE TO BREAK FROM PIN B1. REPLACED B1 PIN IN RELAY BASE K10536. TESTED FOR 28 VOLTS DC AT RIGHT OVERWING SLIDE PRESSURE BOTTLE SQUIB. TEST GOOD.

Source: SDR DL757071594

2005

OTHER · 2005-05-12 Matched by certificate designator
ATA 5414

Part: SKIN — CRACKED (NR 1 PYLON) · airframe 54,630 hrs · 26,420 cycles

APPROX 1 INCH CRACK IN PYLON TORQUE BOX INBOARD SIDE, UPPER FWD CORNER OF FWD ACCESS HOLE, PREVIOUSLY STOP DRILLED. REFERENCE NR CARD 291 PSV 17 CHECK. INSTALLED PERMANENT REPAIR PER SRM 54-51-01D FIG 203.

Source: SDR DL75K050283

2004

AFFECT SYSTEMS · 2004-06-14 Matched by certificate designator
ATA 2131

Part: CONTROLLER — MALFUNCTIONED (LT A/C PACK) · airframe 51,325 hrs · 25,189 cycles

RT CRUISE FL350 GOT CABIN ALT WARNING. CABIN CONTINUED TO CLIMB TO 12,500 FT BEFORE REVERSING. INITIATED DESCENT TO FL240. CABIN WILL NOT HOLD WITH LEFT THROTTLE AT OR NEAR IDLE BOTH DUCT PRESSURES APPEAR NORMAL (40-42 PSI) AT CRUISE FL280 CABIN ALT AT 280 = 4000 FT, NO RATE NOTED IE PRESS STEADY. FOUND LT PAC BITE MSG WOULD NOT ERASE. FOUND LT PAC CONTROLLER FAULTING LT PAC CONTROL VALVE. REMOVED AND REPLACED SAME PER MM, RAN PAC NOW CHECKS GOOD. RAN ENGINES PER PFHB PRESS CABIN TO 5 PSI DIFF PRESS, ALL CHECKS GOOD, NO MESSAGES.

Source: SDR DL75K040554
SMOKE/FUMES/ODORS/SPARKS · 2004-04-03 Matched by certificate designator
ATA 3442

Part: TRANSCEIVER — BURNED (RADAR UNIT) · airframe 50,563 hrs · 24,902 cycles

FAINT ELECTRICAL ODOR IN COCKPIT AFTER ENGINES SHUT DOWN. ISOLATED TO BAD WX RADAR R/T WHICH FAILED ON TAXI IN. DEACT R/T BY PULLING C/BS AND DISPATCHED WITH RADAR INOP PER MEL 34-43-01A. REPLACED R/T UNIT.

Source: SDR DL75K040300
FLUID LOSS · 2004-03-12 Matched by certificate designator
ATA 2910

Part: LINE — RUPTURED (HYD SYSTEM) · airframe 50,319 hrs · 24,803 cycles

ON TOUCHDOWN GOT LEFT HYDRAULIC SYSTEM FAILURE, QUANTITY IS AT .07RF. THE AIRCRAFT WAS TOWED BACK TO THE GATE, INSPECTED THE LEFT LANDING GEAR AND FOUND THE DOWNLOCK ACTUATOR FWD HYDRAULIC LINE LEAKING. THE LINE WAS REPLACED AND THE HYDRAULIC SYSTEM WAS REFILLED AND PRESSURIZED WITHOUT INCIDENT.

Source: SDR DL75K040236

2002

OTHER · 2002-06-17 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (FS 570, S-16L) · airframe 44,849 hrs · 22,498 cycles

FUSELAGE / SKIN / FS 570-660 / STRG. 14L-19L : GROUND DAMAGE SPLICE REPAIR THE FUSELAGE SKIN WAS FOUND WITH 2 DENTS IN CLOSE PROXIMITY TO AN EXISTING SKIN REPAIR DOUBLER. TO REMOVE ALL DAMAGE AND ACCOMPLISH A REPAIR, THE SKIN WAS CUT AT FS 570 BETWEEN THE SKIN LAP JOINTS AT STRG. 14L & 19L AND THE AFT SECTION OF SKIN REMOVED. A NEW SKIN SECTION WAS SPLICE IN WITH AN INTERNAL AND EXTERNAL ALUMINUM SPLICE DOUBLER PER ER/A 383226-14, REV A.

Source: SDR DL757020681

2001

NO TEST · 2001-11-22 Matched by certificate designator
ATA 3397

Part: HARNESS — OPEN (CARGO DOOR) · airframe 43,342 hrs · 21,793 cycles

EMERGENCY LIGHT ON C-2 CARGO DOOR INOP. DOOR HARNESS HAS OPEN. REPLACED SAME.

Source: SDR DL757011842
NO TEST · 2001-08-30 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 42,620 hrs · 21,450 cycles

EMERGENCY LIGHT INOP. AT SEAT 20DEF. REPLACED EMERGENCY LIGHT ASSY. AT 20DEF; OPS CHECK GOOD. DELTA PART NUMBER 333201532 INSTALLED.

Source: SDR DL757011435

2000

NO TEST · 2000-02-20 Matched by certificate designator
ATA 3350

Part: HARNESS — DAMAGED (ROW 21)

SEAT 21 D, E, F EMERGENCY LIGHT INOP. FOUND WIRE HARNESS DAMAGED. REPLACED WIRE HARNESS, OPS NORMAL.

Source: SDR DL757000345

1999

OTHER · 1999-05-16 Matched by certificate designator
ATA 5350

Part: RADOME — BROKEN (FWD FUSELAGE)

ON CLIMBOUT ABOUT 13,000 FT, HEARD TWO LOUD BANGING NOISE FOLLOWED BY LOUD AIR NOISE IN NOSE GEAR AREA. FOUND RADOME AND RADAR ANTENNA DAMAGED. MAINT IN PROGRESS.

Source: SDR DL757991072

1998

VIBRATION/BUFFET · 1998-09-12 Matched by certificate designator
ATA 5510

Part: FAIRING — GAPPED (LT HORIZ STAB)

AIRFRAME BUFFET AFTER TAKEOFF. WORSE WITH INCREASE IN ALT AND SPEED FELT THROUGH CONTROLS FIRST THEN UP THROUGH SEAT. F/A FELT ALL THE WAY TO BACK OF PLANE. INSPECTED FUSELAGE AND WINGS INCLUDING FLT CONTROLS AND FLAPS AND ALSO EMPENNAGE. FOUND LT LWR STAB FAIRING GAPPED, SHIMMED FAIRING. PERFORMED TEST FLT PER SP 4080, NO DISCREPANCIES NOTED BY FLT CREW OR INSPECTOR DURING TEST FLT.

Source: SDR DL757981900
WARNING INDICATION · 1998-05-23 Matched by certificate designator
ATA 2133

Part: OUTFLOW VALVE — FAILED (CABIN)

BOTH 1 AND 2 AUTO PRESS SYSTEMS INOP. REPLACED OUTFLOW VLV.

Source: SDR DL757981105

1997

OTHER · 1997-08-24 Matched by certificate designator
ATA 3520

Part: PSUS — MALFUNCTIONED (CABIN)

THE FOLLOWING PSUS DID NOT OPEN WHEN O2 SYS ACTIVATED PASSING 36,000 FT, WHEN CABIN LOST PRESSURIZATION 2AB, 2CD, 23DEF, 24ABC, 34DEF, 37DEF. DNTC REPLACED ABOVE LISTED PSUS.

Source: SDR DL757971654
WARNING INDICATION · 1997-08-24 Matched by certificate designator
ATA 5230

Part: SEAL — FAILED (CARGO DOOR)

WHILE PASSING THRU 36,000 FT, LOST CABIN PRESSURIZATION. MADE EMERGENCY DESCENT, O2 MASKS AUTO DEPLOYED AT 14,000 FT CABIN ALTITUDE. A 2 FT SECTION OF C2 CARGO DOOR SEAL MISSING ON ARRIVAL ATL. REPLACED DOOR SEAL.

Source: SDR DL757971651
OTHER · 1997-06-19 Matched by certificate designator
ATA 5754

Part: WEDGE — DELAMINATED (NR 9 LE SLAT TE)

THE NR 9 LEADING EDGE SLAT WEDGE WAS DELAMINATED. REPLACED SLAT.

Source: SDR DL757971192

1996

NO TEST · 1996-08-26 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

F/C TRACK LIGHTS INOP. REPAIRED BROKEN WIRES AT FLOOR TRACK, OPN NORM.

Source: SDR DL757961974

1995

WARNING INDICATION · 1995-05-11 Matched by certificate designator
ATA 3230

Part: VALVE — FAILED (LT MLG)

ON TAKEOFF, EICAS PROBE HEAT ADVISORY DISPLAYED. EICAS STATUS NOSE A/G DISAGREE. UNABLE TO RAISE GEAR. RETURNED DFW. FOUND LEFT TRUCK SHUTTLE VALVE FAULTY. REPLACED VALVE, SWUNG GEAR RETURNED TO SERVICE.

Source: SDR DL757952123
FLUID LOSS; WARNING INDICATION · 1995-01-16 Matched by certificate designator
ATA 7261

Part: PUMP — CRACKED (NR 2 ENGINE)

DURING CRUISE, NR 2 ENGINE OIL QUANTITY STEADILY DECREASED. INSPECTION OF NR 2 OIL SYSTEM FOUND THE ENGINE SCAVANGE OIL PUMP WITH A CRACKED PUMP CASE. REPLACED OIL PUMP, OPERATION NORMAL.

Source: SDR DL757950191