N652UA

BOEING 767-322 · 1992 · Fixed-wing multi-engine · 2 engines · 330 seats · Valid Registration

Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

303 reports on file, 1995-02-17 – 2026-10-25.

OTHER · 2026-10-25 Matched by certificate designator
ATA 2565

Part: PIN — SHEARED (NR 3 LATCH) · airframe 134,333 hrs · 20,350 cycles

LEFT OVERWING ESCAPE SLIDE DOOR LATCH NR 3 FOUND NOT FUNCTIONING. RETAINING PIN FOUND SHEARED. LATCH REMOVED IAW AMM 25-65-09-004-001 AND REPLACED IAW AMM 25-65-09-404-007. OPS TESTED GOOD. OVERWING SLIDE DOOR LATCH INSPECTED AND CONFIRMED FITTED IAW AMM 25-65-09-404-007.

Source: SDR CALA2026102720612
WARNING INDICATION · 2026-10-11 Matched by certificate designator
ATA 3430

Part: RECEIVER — FAULTY (RIGHT) · airframe 134,173 hrs · 20,328 cycles

NO LAND 3 ON ASA PERFORMED MCDP TEST 30, FOUND NO INFC FCC ILS BUS R, AND ILS R FAIL. REQUESTING MEL 3431J, DDP FOLLOWED. DISPATCH DESK: 11 NAME: BNC DATE: 05-OCT-26- 3431J APPROVED DEFERING PER MEL 3431J, DDP FOLLOWED. *DM* AFTER DOING BITE 22-02 TASK 801, PLEASE UPDATE LOG WITH FINDINGS SO PARTS CAN BE ORDERED. THANKS RIGHT MMR LRU FAILED. LEFT AND RIGHT MMR SWAPPED AND FAULT FOLLOWED. MMR LEFT AND RIGHT REINSTALLED TO ORIGINAL POSITION. NEEDS TO REPLACE RIGHT MMR PER AMM34-31-01/401. FIM TASK 22-02-00-815-801. MMR LRU PART REPLACE AS SHIPSETS PER IPC 34-31-01-50A AND EC 3431-0144C. LOG STILL ON MEL STATUS. REPLACED RIGHT MMR BOX REF AMM 34-31-01

Source: SDR CALA2026101320331
FLUID LOSS; WARNING INDICATION · 2026-06-29 Unresolved
ATA 8300

Part: CARBON SEAL — LEAKING (NR 2 ENGINE)

DURING CRUISE THE A/C FACE RT OIL PRESSURE LT INTERMITTENT ILLUMINATION AND RT ENG QTY INDICATION 0. OIL PRESS FLUCTUATES DOWN 1 TO 27 TEMP NORMAL. CREW REPORTED THAT APPROXIMATELY TWO HOURS PRIOR TO ARRIVAL, INTERMITTENT ENG2 OIL PRESSURE WARNING INDICATIONS WERE OBSERVED, ACCOMPANIED BY LOW AND FLUCTUATING OIL LEVEL. ENG2 OIL SERVICING CARRIED OUT, 18 CANS OF OIL WERE USED. VISUAL INSPECTION OF THE ENGINE C/OUT WITH NO OBVIOUS OIL LEAKS INITIALLY IDENTIFIED. ENG2 DRAIN MAST CONNECTIONS REMOVED AND PLASTIC BAGS INSTALLED TO ASSIST IN LOCALIZING A POTENTIAL OIL LEAK. EGR PERFORMED. OIL LEAK IDENTIFIED ORIGINATING FROM THE PMA CARBON FIBRE SEAL ON ENG2. TOMC INFORMED, AND AIRCRAFT DECLARED AOG. NO SPARE PARTS OR REQUIRED TOOLING AVAILABLE30.06. FIELD TEAM ARRIVED - READY TO REMOVE CARBON FIBRE FROM PMA. CONTINUED TO REMOVE THE SPACER ON THE SHAFT, RE-INSTALLATION OF THE SPACER INSIDE OF THE GEARBOX & PMA 01.07 ALL ACCESSES REINSTALLED AND ENGINE COWLS CLOSED. EGR TEST AND LEAK CHECK PERFORMED SATISFACTORY. NO LEAK. EPDSC PERFORMED. AIRCRAFT READY FOR DEPARTURE.

Source: SDR 2026F00138
ENGINE FLAMEOUT; WARNING INDICATION · 2026-05-16 Matched by certificate designator
ATA 7200

Part: ENGINE — FAULTED (NR 2) · airframe 132,708 hrs · 20,136 cycles

RT ENG OIL PRESS ZERO SHUT DOWN IN FLIGHT HAD COMP STALLS AND FLAMES REPORTED REFERENCE LOG PAGE 9027944 FOR # 2 ENGINE REPLACEMENT REMOVED AND REPLACED # 2 ENGINE AS PER TASK CARD 64-7100-1-0011 AND 76-0571-8-0015. RAN ENGINE, ALL CHECKS GOOD AND NO LEAKS NOTED

Source: SDR CALA2026052716563
SMOKE/FUMES/ODORS/SPARKS · 2026-03-19 Matched by certificate designator
ATA 2550

Part: DRIVE UNIT — BURNED (ZONE 100) · airframe 131,964 hrs · 20,041 cycles

FWD CARGO AFT PALLET PDU 12L FOUND INOP. CB C173 IN PANEL P35 FOUND TRIPPED. ALL PDUS ON AFT PALLET ARE AFFECTED. UPON FURTHER INVESTIGATION PDU 12L CIRCUIT BOARD FOUND BURNT. PDU 12L REQUIRES REPLACEMENT. PDU12L REPLACED IAW AMM: 25-53-01. OPERATIONAL CHECK SATIS.PARTS USED: 64-2553-3-0160,QTY :1

Source: SDR CALA2026032014703
Earlier reports · 1995–2025 · 298 reports

2025

OTHER · 2025-10-15 Matched by certificate designator
ATA 3350

Part: HOUSING — BROKEN (ZONE 200) · airframe 129,965 hrs · 19,779 cycles

31F EPL HOUSING BROKEN REPLACED BROKEN HOUSING WITH NEW REF CMM 25-23-52. TESTED EMERGENCY LIGHTS REF AMM 33-51-00-715-019-001. OPS CHECK OK

Source: SDR CALA2025101610185
OTHER · 2025-10-08 Matched by certificate designator
ATA 3350

Part: BRACKET — DAMAGED (ZONE 200) · airframe 129,858 hrs · 19,765 cycles

SEAT 31F EMERGENCY PATH LIGHT BRACKET DAMAGED. BRACKET REFITTED IAW B/E PINNACLE CMM 25-21-52.

Source: SDR CALA2025100909832
FALSE WARNING · 2025-10-07 Matched by certificate designator
ATA 3150

Part: PCB — FAULTED (EICAS) · airframe 129,851 hrs · 19,764 cycles

EICAS GEAR NOT DOWN WITH CONFIG ANUNCIATION OCCURED WHEN NOSE GEAR TOUCHED DOWN. CARRIED OUT FIM 31-51 FAULT TREE 812 AND PSEU BITE AS PER FIM 32-09 FAULT TREE 803, PSEU NO PREVIOUS SECTOR FAULTS AND CURRENT FAULTS CLEAR PSEU CLEARED. CARRIED OUT FIM 31-51 FAULT TREE 805 AND FOUND LANDING CONFIGURATION WARNING MODULE FAULTY. REMOVED AS PER AMM TASK 31-51-04-004-133, INSTALLED AS PER AMM TASK 31-51-04-404-014. WEU CARD MODULE TEST CARRIED OUT AS PER AMM TASK 31-51-04-724-154, TEST PASSED EICAS WARNING CLEARED AND ANNOUNCITOR EXTINGUISHED.

Source: SDR CALA2025100809795
OTHER · 2025-08-14 Matched by certificate designator
ATA 3510

Part: SAFETY WIRE — BROKEN (OXYGEN BOTTLE) · airframe 129,210 hrs · 19,681 cycles

CREW OXYGEN CYLINDER VALVE SAFTEY WIRE IS BROKEN, CHECK CORRECT VALVE POSITION AND RE-SAFTEYWIRE. CREW O2 BOTTLE FOUND IN AN UNSAFE CONDITION. RECTIFICATION OUTSTANDING VALVE POSITION CONFIRMED CORRECT, SAFETY WIRE RE APPLIED AND SECURED. WRT AMM 35-11-00-206-233.

Source: SDR CALA2025081507845
OTHER · 2025-08-01 Matched by certificate designator
ATA 3350

Part: SIGN — DETACHED (ZONE 200) · airframe 129,068 hrs · 19,662 cycles

DOOR 1L EMERGENCY EXIT SIGN FELL OFF RESECURED EMERGENCY EXIT LIGHT LENS COVER AT DOOR 1L REF AMM 33-51-01-402-030. ADDED SDR DATA

Source: SDR CALA2025080407244
WARNING INDICATION · 2025-06-23 Matched by certificate designator
ATA 2421

Part: IDG — FAULTED (NR 2) · airframe 128,576 hrs · 19,597 cycles

RT GEN DRIVE LIGHT ILLUMINATED.FL310 35 MINS INTO FLIGHT.. UPDATE WITH EICAS MESSAGE, R GEN DRIVE HIGH IDG RISE TEMP UPDATE WITH BPCU INFO REMOVED AND REPLACED #2 ENGINE IDG AS PER AMM 24-11-01-404-001-006. OPS CHECK GOOD. FOUND OIL LEAKING FROM IDG SERVICE OVERFLOW COUPLING 76-2411-3-0003. C/W REQUIRED IDT INSPECTION OF IDG FEEDER CABLE INSTALL REFF AMM 24-11-01. REMOVED AND REPLACED E2 IDG SERVICE OVERFLOW DRAIN COUPLING AS PER AMM 24-11-03. LEAK CHECK GOOD.

Source: SDR CALA2025062505870
OTHER · 2025-05-02 Matched by certificate designator
ATA 5330

Part: BEAR STRAP — CRACKED (ZONE 200) · airframe 127,998 hrs · 19,521 cycles

R1 FWD SERVICE DOOR AFTER CORNER - DURING HFEC OPEN HOLE INSPECTION WAS FOUND HOLES WITH CRACK INDICATION.UPDATE GENERATED DUE REPAIR ACCOMPLISHMENT CLASSIFIED AS MAJOR REPAIR. (CHANGE ATTRIBUTES). UPDATE GENERATED DUE REPAIR ACCOMPLISHMENT CLASSIFIED AS MAJOR REPAIR. THE FUSELAGE SKIN 1R DOOR CUTOUT AFTER LOWER CORNER BEAR STRAP WAS REPAIRED AT GIG. THE REPAIR IS A PERMANENT SOLUTION WITH INSPECTION REQUIREMENTS. ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF LATEST REVISION OF EC/RA 5310-08568 ON OR BEFORE THE AIRCRAFT REACHES 37.500 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 3.000 FLIGHT CYCLES. REF ECRA 5310-08568: ACCOMPLISH INSPECTION EQUIREMENTS PER PART 2 OF LATEST REVISION OF EC/RA 5310-08568.

Source: SDR CALA2025050504460
OTHER · 2025-05-02 Matched by certificate designator
ATA 5330

Part: BEAR STRAP — CRACKED (ZONE 200) · airframe 127,998 hrs · 19,521 cycles

L1 FWD ENTRY DOOR AFTER CORNER - THERE ARE TWO CRACKS AT 10 AND 4 O'CLOCK IN THE LOWER ON THE AFTER CORNER. UPDATE GENERATED DUE REPAIR TO BE ACCOMPLISHED CLASSIFIED AS MAJOR. THE FUSELAGE SKIN 1R DOOR CUTOUT AFTER LOWER CORNER BEAR STRAP WAS REPAIRED AT GIG. THE REPAIR IS A PERMANENTSOLUTION WITH INSPECTION REQUIREMENTS. ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF LATEST REVISION OF EC/RA 5310-08566 ON OR BEFORE THE AIRCRAFT REACHES 37.500 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 3.000 FLIGHT CYCLES. REF ECRA 5310-08566: ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF LATEST REVISION OF ECRA 5310-08566 ON OR BEFORE THE AIRCRAFT REACHES 37.500 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 3.000 FLIGHT CYCLES.

Source: SDR CALA2025050504459
OTHER · 2025-04-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — DAMAGED (ZONE 200) · airframe 127,998 hrs · 19,521 cycles

PAX COMPARTMENT FLOOR PANEL - IT NECESSARY TO PERFORM A REPAIR ON THE FLOOR BEAM LOCATED RBR 54.75 BETWEEN STA 785.9 / STA 933 DUE TO THE EXISTING REPAIR IN THE AREA HAVE NOT THE HOLES OF FLOOR PANEL ( P74, P80, P81 AND P82) AS PER NR: 002594240, NR: 002594252, NR: 002594246 AND NR: 002594234. ACCOMPLISHED REPAIR ON THE FLOOR BEAM AS PER SRM 53-00-51-2R-3. PERFORMED BY: U422642, U419664, U426239, U395678 NECESSARY MORE INFORMATIONS ABOUT THE ESFR. INCLUDED ESFR INFORMATIONS ESFR INFORMATION HAS ADD AND APPROVED. THE REPAIR HAS BEEN PERFORMED IN REF SRM 53-00-51-2R-3 UNDER NR2594240, NR2594252, NR2594246, NR2594234

Source: SDR CALA2025050104390

2024

NO TEST · 2024-12-19 Matched by certificate designator
ATA 3350

Part: LENS — DETACHED (ZONE 200) · airframe 126,927 hrs · 19,379 cycles

OVERWING EXIT SIGN AT AICRAFT RIGHT IS HANGING DOWN. OVERWING EXIT SIGN R-H SIDE CEILING POSITION LENS COVER REFITTED AND SECURED PER AMM 33-51-01

Source: SDR CALA2024122301625
OTHER · 2024-07-23 Matched by certificate designator
ATA 2433

Part: TRANS RECTIFIER — FAULTED (ZONE 100) · airframe 125,076 hrs · 19,132 cycles

767 FUEL FEED SYSTEM HEALTH CHECK - LH FWD BOOST PUMP - VOLTAGE INBALANCE OF FWD LH FUEL PUMP OUT OF TOLERANCE. LH TRANSFORMER RECTIFIER UNIT REPLACED AS PER AMM 24-32-01-004-001 AND 24-32-01-404-005. LH TRU OP-CHECK TEST OK, FWD LH FUEL PUMP VOLTAGE INBALANCE NOW WITHIN LIMITS. LH TRANSFORMER RECTIFIER UNIT REPLACED AS PER AMM 24-32-01-004-001 AND 24-32-01-404-005. LH TRU OP-CHECK TEST OK, FWD LH FUEL PUMP VOLTAGE INBALANCE NOW WITHIN LIMITS.

Source: SDR CALA2024072400275
OTHER · 2024-06-13 Matched by certificate designator
ATA 3460

Part: FMC — FAULTED (LEFT) · airframe 124,676 hrs · 19,077 cycles

LEFT FMC FROZE. UNABLE TO INPUT COMMAND. LEFT AIRSPEED BUG +/- 30 KNOTS FROM STEP F (7) TO COMPLETION (TEST FLIGHT MANAGEMENT COMPUTER). REMOVED AND REPLACED LEFT FLIGHT MANAGEMENT COMPUTER AS PER AMM 34-61-01-024-001-001 AND AMM 34-61-01-424-005-001 UP TO STEP F (6). ALL SOFTWARE FOR LEFT FMC IS UP TO DATE AND CORRECT. NEW NAV DATA NEEDS TO BE INSTALLED AND ALSO AMM 34-61-01-424-005-001 COMPUTER, FLT M OFF 19-3461-9-0004 9495 ON 19-3461-9-0004 5565 SEE LOG PAGE 827379 FOR NAV DATA INSTALL COMPLIED WITH TEST FLIGHT MANAGEMENT COMPUTER FROM F (7) TO COMPLETION ALL CHECKS GOOD 34-61-01-424-005-001.

Source: SDR CALA2024061701814
WARNING INDICATION · 2024-06-01 Matched by certificate designator
ATA 3244

Part: TIRE — LOW PRESSURE (NR 2 MLG) · airframe 124,505 hrs · 19,053 cycles

FOUND #2 MLG TIRE PRESSURE WAS UNDER REINFLATION RANGE. REMOVED AND REPLACED #2 TIRE. AMM 32-45-01.

Source: SDR CALA2024060401692

2022

OTHER · 2022-04-27 Matched by certificate designator
ATA 5210

Part: DOOR — BINDING (COCKPIT) · airframe 117,138 hrs · 18,057 cycles

COCKPIT DOOR DIFFICULT TO CLOSE APPEARS TO BE BINDING ON THRESHO LD TIGHTENED COCKPIT DOOR SILL, OPS CHECK OK.

Source: SDR CALA2022042701092

2021

FLT CONT AFFECTED · 2021-11-14 Matched by certificate designator
ATA 2710

Part: AILERON SYS — MALFUNCTIONED (RT) · airframe 116,079 hrs · 17,888 cycles

ON APP W/FLAPS 15 - RT AIL DROOPED FULL AND L AIL AT HALF. TE DISAGREE EICAS. FOR THE RIGHT INBD AILERON IS BYPASSING OR A PROBLEM WITH INBD AILERON DROOP MECHANISM. ITEM LOCKED FOR FURTHER CHECKS. UNLOCKED FOR L/P UPDATE LOGPAGE LOOCKED AS REQ''D. RIGHT INBD AILERON POSITION INDICATES LOWER THAN LEFT INBD SUSPECT INBD CENTER PCA IS BYPASSING. ISOLATED BY CYCLING CENTER AILERON WITH FLAPS SET TO 15. RIGHT INBD AILERON ALSO CONTINUES & RIGHT HYDRAULICS OFF & ON WHILE LISTENING AND FEELING INBD TO DROP FULLY DOWN WITH HYDRAULICS OFF WHILE LEFT INBD AILERON PCA, WHICH WAS EMITTING A HIGH FREQ SOUND & VIBRATING, WHILE THE REMAINS AT LAST POSITION. ACCOMPLISHED FIM 27-11 TASK 807 FOR OTBD PCA SOUNDED & FELT NORMAL. AILERON DROOP PROBLEM, NO FAULTS FOUND. SUSPECT ONE OF THE PCA''S UNLOCKED FOR MAINTENANCE UPDATE. LOG PAGE LOCKED AFTER MAINTENANCE UPDATE. UNLOCKING L/P FOR MAINTENANCE UPDATE. LOG PAGE LOCKED AFTER UPDATE. SDR IS FLAGGED DUE TO EMERGENCY LANDING DECLARED BY THE FLIGHT CREW.

Source: SDR CALA2021111702109
WARNING INDICATION · 2021-11-11 Matched by certificate designator
ATA 2841

Part: NONE — NONE (NA) · airframe 116,063 hrs · 17,885 cycles

CREW REPORT, L MAIN FUEL TANK AND TOTAL QTY INDICATION READING BLANK LEFT FLIGHT DECK FUEL QTY INDICATOR DEFERRED PER B767-300 MEL LEFT FLIGHT DECK FUEL QTY INDICATOR DEFERRED PER B767-300 MEL 2841R.M PROCEDURE COMPLIED WITH. REF LOG PAGE 7401962 FOR 2841R. M PROCEDURE COMPLIED WITH. REF LOG PAGE 7401962 FOR SECOND DEFERRAL FOR TOTAL FUEL QTY INDICATION. SECOND DEFERRAL FOR TOTAL FUEL QTY INDICATION. DISPATCH DESK: 3361 NAME: G.D. OK TO DEFER L MAIN TANK QTY INDICATION PER MEL.

Source: SDR CALA2021111102091
OTHER · 2021-07-20 Matched by certificate designator
ATA 2751

Part: TRANSMITTER — OUT OF ADJUST (TE FLAP SYS) · airframe 114,926 hrs · 17,701 cycles

TE FLAPS ASYM FLAPS STUCK LESS THAN 5 INTERROGATED FSEU ...MSG "TE ASYM XMT 1-8". FAULT CODE 27-51083. FLAPS LOCKED OUT. WILL NOT MOVE IN ALT AS WELL AS HYD. TROUBLESHOT PER FIM 27-51 TREE 811 AND ADJ #8 TRANSMITTER PER AMM 27-51-45-822-161. GROUND CK GOOD ADD EMP:352640

Source: SDR CALA2021072101154
OTHER · 2021-06-14 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 114,637 hrs · 17,648 cycles

P61 SQUIB TEST FOUND LH & RH SPOILER AND SLIDE LIGHT INOP, REF NRC 9130152 TROUBLESHOOTING CARRIED OUT FOUND R/H AND L/H POWER SUPPLY BATTERIES WAS POWER LOW,R/H AND L/H OFF WING SLIDE POWER SUPPLY ASSY AND BATTERIES REPLACED AND SQUIB TEST TEST CARRIED OUT RESU LT NORMAL AS PER FIM TASK 25-65 FAULT TREE818,TASK25-65,FAULT TREE 820,AMM 25-65-17 AND AMM 26-65-00. ADD EMP:V919559 FORM 44-0008 ITEM 1 TO 4 ACCOMPLISHED

Source: SDR CALA2021061400872
OTHER · 2021-06-11 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1219 S38L) · airframe 114,637 hrs · 17,648 cycles

B767-06-3-7022 - FX STA 1219 S38L AREA FOUND SUSPECT CORRODED. R EF N/R L/P 9130407 GENERATE A DIP FOR INSPECTION REQUIREMENT AS PER EC/RA 5360-0160 3 REV-PART 2 ADD EMP:V896876 FUSELAGE SKIN STA1219 STR38L INTERIM REPAIRED AS PER EC/RA5360-0 1603 REV-PART1 ATTACHED FORM44-0008 ITEM 1 TO ITEM 38 ACCOMPLISH ED GENERATED A DIP ACCOMPLISHED INSPECTION PER CATEST REV OF EC/ RA5360-01603 PART2 BEFORE REACHING 37,500 TOTAL FLIGHT CYCLES. R EPEAT THE INSPECTION AT INTERNAL NOT TO EXCEED ADD EMP:V912779 9000 FLIGHT CYCLES, THEREAFTER INSPECTED AND APPROVED BY HX146606 ADD EMP:V898549

Source: SDR CALA2021061400855

2020

OTHER · 2020-07-17 Matched by certificate designator
ATA 5610

Part: WINDOW — LEAKING (L2) · airframe 114,451 hrs · 17,601 cycles

CAPTAIN STATED LOUD SQUEEL DEVELOPED AT FL380 AND CABIN PRESSURE AT 6.5. DESCENDED TO FL 320 AND CABIN PRESSURE AT 6.0, NO HELP. SQUEEL SILENCED AT FL260 AND CABIN PRESSURE AT 1900. SOUND COMING FROM FWD SIDE OF THE CAPTAIN`S SLIDING WINDOW FROM TOP TO 1/2 WAY DOWN FWD SIDE. INSPECTED WINDOW, NO DEFECTS NOTED. PRESSURIZED ACFT NOTED NO NOTICABLE AUDIBLE SQUEELING FROM EITHER NR 2 WINDOW INSIDE. THE OUTSIDE HAD SMALL AMOUNT OF BUBBLES USING WATER AND SOAP SOLUTION IN THE UPPER FWD, LOWER FWD AND LOWER AFT CORNERS, BUT COULD NOT FEEL ANY AIR LEAKAGE IAW AMM 05-51-24. REPLACED THE L2 FLIGHT DECK WINDOW IAW AMM. OK FOR SERVICE.

Source: SDR CALA2020072001062

2019

OTHER · 2019-10-22 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (FWD GALLEY) · airframe 112,995 hrs · 17,383 cycles

PER TASK CARD 63-3310-1-7300 FWD GALLEY SIDE 2EA EMRE LT INOP REF BSH N0052 REPLACED FWD GALLEY SIDE 2EA EMER LT AND LT TEST R ESULT IS NORMAL AS PER AMM 33-51-05 R128.

Source: SDR CALA2019102501807
OTHER · 2019-10-22 Matched by certificate designator
ATA 3350

Part: LIGHT — CRACKED (ROW 6K) · airframe 112,995 hrs · 17,383 cycles

REF TO BSH N0481 CABIN 6K AISLE EMER LT ASSY HAVE CRACK REF BSH N0481 REPLACED 6K AISLE EMER LT ASSY AND LT TEST RESULT IS NORMAL AS PER AMM 33-51-05 R128.

Source: SDR CALA2019102501810
OTHER · 2019-10-22 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 112,995 hrs · 17,383 cycles

PER TASK CARD 63-3350-1-7100 38R AISLE EMERGENCY LIGHT AT CEILIN G PANEL DO NOT COME ON REF TO BSH N0170 REPLACED 38R AISLE EMER LT AT CEILING PANEL AND LT TEST RESULT IS NORMAL AS PER AMM 33-51-05 R128.

Source: SDR CALA2019102501808
OTHER · 2019-10-22 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (SEAT 38) · airframe 112,995 hrs · 17,383 cycles

PER TASK CARD 63-3350-1-7100 38F EMER LT INOP REF TO BSH N0125 REPLACED 38F EMER LT AND LT TEST RESULT IS NORM AL AS PER AMM 33-51-05 R128.

Source: SDR CALA2019102501811
NO TEST · 2019-09-23 Matched by certificate designator
ATA 3397

Part: CONNECTOR — BROKEN (CABIN) · airframe 112,954 hrs · 17,378 cycles

CROSS AISLE FLOOR MARKER LOOSE BETWEEN SEATROW 20DEF AND 21DEF. LIGHT TEST FAILED ON CROSS AISLE FLOOR MARKER AND 4 OVERWING EXITS LOWER EXIT SIGNS THESE EMERGENCY LIGHTS CAN ONLY BE SWITCHED ON FROM COCKPIT. NOT FROM FA PANEL TEST SWITCH. FOUND SOLDERING OF CONNECTOR OF LIGHT STRIP BROKEN. REPAIRED SOLDERING IAW SWPM 20-12-01. TEST EMERGENCY LIGHTS IAW AMM 33-51-10-712-130. ALL SATIS.

Source: SDR CALA2019092301631
OTHER · 2019-05-20 Matched by certificate designator
ATA 2520

Part: PANEL — UNSECURE (CABIN) · airframe 111,508 hrs · 17,192 cycles

ROW 27, 28 DEF SEATS O2 PANEL OPENED DURING TAKE OFF. PER CREW TOMC MO LOG#3251826 HAS BEEN CREATED BY CREW. TOMC MO FOUND PSU PANEL AT ROW 27 TO BE IN THE UNLATCHED AND DOWN POSITION. RESTOWED PSU PANEL IAW AMM 25-23-01-404-005. OPS CHECKED GOOD.

Source: SDR CALA2019052000804

2017

OTHER · 2017-12-30 Matched by certificate designator
ATA 3350

Part: LIGHT — DAMAGED (ROW 21) · airframe 106,355 hrs · 16,491 cycles

EMERGENCY EXIT LIGHT AT ROW 21 CENTER HAS DAMAGE. REPLACED THE POWER SUPPLY AND LIGHT . CHECKED OK.

Source: SDR CALA2017123004693
NO TEST · 2017-07-21 Matched by certificate designator
ATA 3350

Part: LIGHT — BROKEN (CABIN) · airframe 104,424 hrs · 16,227 cycles

ROWS 4,5,6 SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTS DO NOT WORK WITH ALL EMERGENCY SWITCH IN CABIN AND INCLUDING P5 PANEL SWITCH. TROUBLESHOT BATTERY PACK FUSE SHORT PER WDM 33-51-15. FOUND ROW 5D SEAT EEL ASSY BROKEN REPLACED OPS CHECK GOOD.

Source: SDR CALA2017072102315
SMOKE/FUMES/ODORS/SPARKS · 2017-07-10 Matched by certificate designator
ATA 2497

Part: WIRE — BURNED (CIRCUIT BREAKER) · airframe 104,313 hrs · 16,209 cycles

CREW REPORTED AFTER REACHING CRUISE ALTITUDE, NO POWER TO AFT GALLEYS. NO CIRCUIT BREAKERS TRIPPED, ALL GALLEY EQUIPMENT OFF. RESET UTILITY BUSS, GALLEY POWER RESTORED. JUST PRIOR TO TURNING GALLEY APPLIANCES ON, THE FLT ATTENDANT REPORTED AN ACRID ODOR FROM AFT GALLEY CIRCUIT BREAKER PANEL. G ALLEY POWER SECURED, NO FURTHER ODOR FOUND. TWO WIRES WITH BLACK INSULATON AT TERMINAL ENDS AT CIRCUIT BREAKER C404 AT AFT GALLEY LEFT SIDE CIRCUIT BREAKER PANEL. TERMINATED THE WIRES AND REMOVED AND REPLACED C404 CIRCUIT BREAKER. ALL WORK ACCOMPLISHED IAW SWPM 20-30-11 AND WDM 25-31-23. APPLIED POWER TO AFT GALLEY AND NO ISSUES NOTED.

Source: SDR CALA2017071002135
F.O.D. · 2017-07-07 Matched by certificate designator
ATA 7230

Part: BLADES — DAMAGED (NR 1 ENGINE) · airframe 104,280 hrs · 16,204 cycles

DAMAGE FOUND TO A FAN BLADE ON NR 1 ENG, SUSPECT BIRD INGESTION. REMOVED 2 EACH BLADES BLADE NUMBER 12 AND BLADE NUMBER 31 BLADE IN NUMBER 12 POS S/N 3505 OFF S/N ON 9068 BLADE IN POS 31 S/N OFF 3444 S/N ON 9050 REF AMM TASK 72-31-02-004-001-N00 AND TASK 72-31-02-404-021-N00.

Source: SDR CALA2017070702107
SMOKE/FUMES/ODORS/SPARKS · 2017-06-10 Matched by certificate designator
ATA 2530

Part: OVEN — FAILED (GALLEY) · airframe 103,993 hrs · 16,166 cycles

OVEN 106 FWD BURNS FOOD AND SMOKES. TEMP UNCONTROLABLE. FIRE HAZARD. R & R THE OVEN. ALL OPS OK.

Source: SDR CALA2017061001787
SMOKE/FUMES/ODORS/SPARKS · 2017-06-09 Matched by certificate designator
ATA 2530

Part: CONTROLLER — FAULTY (OVEN) · airframe 103,986 hrs · 16,165 cycles

OVEN 106 OVERHEATS WHILE COOKING. BURNS FOOD AND SMOKES. TEMP CONTROL UNCONTROLLABLE. REMOVED AND REPLACED OVEN TEMP CONTROLLER. OVEN OPERATES NORMAL WITH CONTROLLING (CYCLING) TEMPERATURE.

Source: SDR CALA2017060901740
SMOKE/FUMES/ODORS/SPARKS · 2017-05-05 Matched by certificate designator
ATA 2530

Part: OVEN — ODOR (GALLEY) · airframe 103,558 hrs · 16,108 cycles

FORWARD GALLEY OVEN 106 HAS ELECTRICAL BURNING SMELL. REMOVED AND REPLACED OVEN POS 106 IN FWD GALLEY. OPS CHK GOOD.

Source: SDR CALA2017050501253
OTHER · 2017-03-22 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAULTY (EMERGENCY LIGHTS) · airframe 103,102 hrs · 16,045 cycles

R2 DOOR EMERGENCY EXIT LIGHT AT FWD LOWER POSITION REMAINS ILLUMINATED WITH EMERGENCY LIGHT SWITCH IN ANY POSITION . PERFORMED T/S IAW WDM 33-51-14. FAULTY BATTERY PACK M1556 CONFIRMED. R & R THE BATTERY PACK IAW AMM 33-51-07. OPS OK.

Source: SDR CALA2017032400686
OTHER · 2017-03-21 Matched by certificate designator
ATA 3350

Part: SIGN — MALFUNCTIONED (EMERGENCY LIGHTS) · airframe 103,096 hrs · 16,044 cycles

R2 DOOR LOWER FWD EMERGENCY EXIT SIGN ILLUMINATED WITH SWITCH ON OR OFF. REMOVED AND REPLACED LOWER FWD EMERGENCY MAKER EXIT SIGN, OPS CHECK GOOD.

Source: SDR CALA2017032400680

2016

NO TEST · 2016-12-05 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 101,964 hrs · 15,889 cycles

R1 AND LEFT O/W SECOND FROM AFT EMERGENCY LIGHTS ARE INOP. RELAMPED OPS CHECK GOOD REF AMM 33-51-06.

Source: SDR CALA2016120501022
OTHER · 2016-09-01 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (BS 1197) · airframe 101,038 hrs · 15,754 cycles

PREVIOUS BLEND OUT FOUND ON FUSELAGE STA 1197+66 AND 1197+88 STR 35L. HFEC INSPECTION RESULTED IN A CRACK MEASUES 0.025. SKIN THICKNES S IS 0.160. REPAIRED AS PER SRM 53-00-01, REPAIR 14, FIG 201, TABLEII. PAGE 205.THIS IS A CATEGORAY B REPAIR INSPECTION REQUIR MENTS IS 37,000 FLIGHT CYCLES FROM DATE OF DELIVERY, OR 6,000 CYCLES FROM DATE OF REPAIR INSTALLATIONS WHICH EVER IS GREATER. AND 12,000 FLIGHT CYCLES INTERVAL.

Source: SDR CALA2016090100618
OTHER · 2016-09-01 Matched by certificate designator
ATA 5410

Part: STRUT — CRACKED (LT NACELLE) · airframe 101,038 hrs · 15,754 cycles

SUPPORT TASK EA 5100-02450 OP4. LT STRUT NAC STA 156 WL 145 FOUND REPAIR AROUND DRAIN HOLE. REMOVED EXISTING REPAIR L/H STRUT NAC STA 156, CRACK MEASURED 0.080. REPAIRED AS PER SRM 54-53-01, REPAIR 10, FIG 201, REPAIR B.

Source: SDR CALA2016090100616
OTHER · 2016-08-24 Matched by certificate designator
ATA 5410

Part: SPAR — CRACKED (NR 2 PYLON) · airframe 101,038 hrs · 15,754 cycles

NR 2 PYLON UPPER SPAR WEB FOUND CRACKED AT NAC STA 175. FILLER FABRICATED IAW ECRA 5410-01834 PART 1 INTERIM REPAIR, ALL REPAIR PARTS INSTALLED TO WEB REPAIR AREA, FILLET SEAL EDGE APPL IED PER ECRA 5410-01834 PART 1, HFEC INSP CARRIED OUT IAW NTM PART 6, 51-00-19, RESULT NO CRACK FOUND.

Source: SDR CALA2016082400574
OTHER · 2016-08-23 Matched by certificate designator
ATA 5414

Part: SKIN — CRACKED (NR 2 NACELLE) · airframe 101,038 hrs · 15,754 cycles

NR 2 PYLON PANEL 446BL CUTOUT S KIN FOUND CRACKED. REPAIRED IAW SRM 54-53-01 REPAIR 7 FIG 201 DETAIL I.

Source: SDR CALA2016082300567
NO TEST · 2016-02-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles

EMERGENCY EXIT LIGHT INOPERATIVE, DOOR 2 RT SILL LIGHT. REPLACED BATTERY AT M734 IAW MM 33-51-07.

Source: SDR CALA2016022995174
NO TEST · 2016-02-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles

EMERGENCY EXIT SIGN INOPERATIVE AT AFT GALLEY RT SIDE. REPLACED BATTERY AT M734 IAW MM 33-51-07.

Source: SDR CALA2016022995173
NO TEST · 2016-02-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles

EMERGENCY EXIT SIGN INOPERATIVE, JUST ABOVE & AFT OF ROW 39 RT. REPLACED BATTERY AT M734 IAW MM 33-51-07.

Source: SDR CALA2016022995172
NO TEST · 2016-02-24 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 99,691 hrs · 15,570 cycles

EXTERIOR EMER EXIT LIGHT INOPERATIVE, FIRST LIGHT JUST AFT OF RT WING TE ON FUSELAGE. RELAMPED. OPERATIONS CHECKED NORMAL.

Source: SDR CALA2016022995175
NO TEST · 2016-02-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles

EMERGENCY EXIT LIGHTS INOPERATIVE. CEILING ABOVE ROWS 29 RT THROUGH AFT GALLEY RT SIDE. REPLACED BATTERY AT M734 IAW MM 33-51-07 PG 201.

Source: SDR CALA2016022995171

2015

OTHER · 2015-07-08 Matched by certificate designator
ATA 5230

Part: SKIN — DENTED (CARGO DOOR) · airframe 94,896 hrs · 14,929 cycles

BULK CARGO DOOR, SKIN DENTED 2 PLACES ABOVE EXISTING DOUBLER. DENTS FOUND OUT OF SRM LIMITS. REMOVED DOUBLER & ENCOMPASSED INTO ONE REPAIR. REPAIRED IAW SRM 52-30-01 FIG 201 REPAIR 6. THIS IS A CAT B REPAIR.

Source: SDR CALA2015071094075
NO TEST · 2015-03-13 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 96,145 hrs · 15,100 cycles

SEAT MOUNTED EEL INOPERATIVE AT SEAT ROWS 35 RT - 39 RT. IAW WD 33 51 12 & MM 33 51 07, FOUND BATTERY M99084 BAD. CONNECTED NEW BATTERY & CHARGER TO CONNECTOR D9819P. ALL LIGHTS CAME ON.

Source: SDR CALA2015031793435
NO TEST · 2015-03-12 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles

FLOOR MOUNTED EEL STRIP INOPERATIVE AT MID LT LAVATORY. REPLACED BATTERY FLOOR MOUNTED EEL STRIP AT MID LT LAVATORY. OPERATIONS CHECKED NORMAL.

Source: SDR CALA2015031793432
NO TEST · 2015-03-12 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles

SEAT MOUNTED EMER EXIT LIGHT INOPERATIVE AT SEAT ROW 28 LT. CRIMPED FEEDER. OPERATIONS CHECKED IAW MM 33-51-00-501.

Source: SDR CALA2015031793433
NO TEST · 2015-03-12 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles

FLOOR MOUNTED EEL STRIP INOPERATIVE AT LT AISLE JUST FWD OF LT AFT DOOR. CRIMPED CABLE IAW SWPM 20- 30-12 & AMM 33-51-10. OPERATIONS CHECKED OK.

Source: SDR CALA2015031793434
NO TEST · 2015-03-12 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles

FLOOR MOUNTED EEL STRIP INOPERATIVE AT CTR SEAT ROW 19. REPLACED BATTERY FLOOR EEL STRIP AT ROW 19. OPERATIONS CHECKED NORMAL.

Source: SDR CALA2015031793431
NO TEST · 2015-03-12 Matched by certificate designator
ATA 3350

Part: SIGN — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles

GREEN EMER EXIT SIGNS INOPERATIVE AT BOTH LT OVERWING EXIT DOORS. REPLACED BATTERY EXIT SIGNS. OPERATIONS CHECKED NORMAL.

Source: SDR CALA2015031793430

2014

OTHER · 2014-10-27 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AFT PIT STATION 1285 HAS CORROSION ON J CHORD UNDER SIDE. REMOVED, FABRICATED & REPLACED STATION 1285 J CHORD PN 146T1210-20 IAW DWG 146T1210 REV C & SRM 51-40-02.

Source: SDR CALA2014102992623
OTHER · 2014-10-26 Matched by certificate designator
ATA 5414

Part: SKIN — DAMAGED (NR 1 NACELLE) · airframe 94,896 hrs · 14,929 cycles

NUMBER 1 ENG LT & RT TR'S LOWER INNER AFT BIFURCATION FAIRING S SKIN FOUND PITTED DURING GSO C-16 VISIT. AFTER DAMAGE REMOVAL & BLENDING REMAINING MATERIAL IS .081 INCHES WITH .019 INCHES REMOVED, OUT OF LIMITS OF SRM 54-33-01. WORK STEPS OF ECRA 7830-02831 ACCOMPLISHED INCLUDING FPI & HFEC INSPECTION WITH NO ADVERSE FINDINGS ON INBD OR OTBD TR'S.

Source: SDR CALA2014102792618
OTHER · 2014-10-18 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

FORWARD CGO DOOR CUT OUT SILL SUPPORT STRUCTURE CORRODED AT FS 588. R & R FWD CGO DOOR LOWER SILL PN 143T8204-1 WITH NEW SILL IAW SRM 51-40-02 & DWG 143T8513. THIS IS A PSE REPLACEMENT WITH NO INSPECTIONS REQUIRED OUTSIDE OF NORMAL MPD REQUIREMENTS. OPERATIONS CHECKED GOOD OF FWD CGO DOOR FUNCTION FIT & FAIR IAW AMM 52-33-00.

Source: SDR CALA2014102192541
OTHER · 2014-10-18 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD PIT LOWER DOOR SILL BALL PANEL SUPPORT BEAM HAS CORROSION ON WEB & CHANNEL STATION 540 - 565 RBL 45. REMOVED WEB, FABRICATED WEB PN 451T2603-41 IAW DWG 451T2603 REV C. INSTALLED WEB & NEW CHANNEL PN 452T1137-23 IAW SRM 51-40- 02 & DWG 451T1602. THIS IS A REPLACEMENT WITH NO INSPECTIONS REQUIRED OUTSIDE OF NORMAL MPD REQUIREMENTS.

Source: SDR CALA2014102192540
OTHER · 2014-10-11 Matched by certificate designator
ATA 5311

Part: FRAME — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR FRAME AT BS 500 RBL 15 J CHORD IS CORRODED UNDER NUTPLATES. REMOVED DAMAGED FRAME J CHORD ENTIRE LENGTH & FABRICATED & INSTALLED A NEW 143T1060-25 J CHORD IAW DWG 143T1203 REV A & SRM 51-40-02.

Source: SDR CALA2014101692455
OTHER · 2014-10-11 Matched by certificate designator
ATA 5311

Part: FRAME — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR BS 632 RBL 28 FRAME J CHORD CORRODED UNDER NUTPLATES. REMOVED ENTIRE J CHORD SECTION & REPLACED WITH A NEW J CHORD PN 143T1060-29 IAW DWG 143T1209 SHEET 4 REV C & SRM 51-40-02 ON NON-ROUTINE 40976.

Source: SDR CALA2014101692453
OTHER · 2014-10-11 Matched by certificate designator
ATA 5313

Part: STRINGER — DENTED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AREA AFT OF BULK CARGO COMPARTMENT LOWER BILGE STRINGER IS DENTED SEVERAL AREAS AT BS 1540 - 1560 STRINGER 36L. DENTS EXCEED SRM 53-00-03 DETAIL III LIMITS. REMOVED DAMAGED SECTION OF STRINGER 36L, FABRICATED STRINGER REPAIR CHANNEL, SPLICE ANGLES, FILLERS & INSTALLED IAW SRM 53-00-03 REPAIR 2 DETAIL IV ON NON-ROUTINE 41181.

Source: SDR CALA2014101692452
OTHER · 2014-10-11 Matched by certificate designator
ATA 5311

Part: FRAME — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR STATION 544 RBL 19 FRAME J CHORD IS CORRODED UNDER NUTPLATES. REMOVED DAMAGED FRAME J CHORD ENTIRE LENGTH, FABRICATED A NEW PN 143T1060-27 J CHORD & INSTALLED IAW DWG 143T1205. CAT A PERMANENT REPAIR.

Source: SDR CALA2014101692454
OTHER · 2014-10-11 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

BS 1263 FRAME UPPER J CHORD IS CORRODED AT NUTPLATES LBL 36. REMOVED FRAME J CHORD, FABRICATED & INSTALLED A NEW J CHORD PN 146T1209-26 IAW DWG 146T109 & SRM 51-40-02 ON NON-ROUTINE 41233.

Source: SDR CALA2014101692451
OTHER · 2014-10-10 Matched by certificate designator
ATA 5320

Part: STRAP — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

WEB UPPER STRAP IS CORRODED AT NUTPLATES BS 1219, LBL 22 - LBL 30. REMOVED DAMAGED CORROSION FROM AFT PIT FRAME J CHORD AT BS 1219, MATERIAL REMAINING EXCEEDS SRM 53-00-07 LIMITS. CUT OUT DAMAGED CHORD & REPLACED ENTIRE PN 146T1060-2 CHORD IAW DWG 146T0250 REV A & SRM 51-40-05 & 51-40-02.

Source: SDR CALA2014101692438
OTHER · 2014-10-10 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles

BS 347 FLOORBEAM T CAP CORROSION REMOVED & REMAINING MATERIAL BEYOND SRM LIMITS. DAMAGED T CAP CUT OUT BETWEEN RBL 4 & RBL 87. AFTER TRIMMING THE CHORD THERE IS SHORT ED IN THE WEB DUE TO EXISTING FASTENER LOCATIONS FROM A PREVIOUS REPAIR AT RBL 27 - 33. REMOVED EXISTING REPAIR AT WEB AT RBL 27 - 33, FABRICATED A NEW T CHORD, SPLICE ANGLES, STRAP & FILLERS IAW REO G18232 REV A & ECRA 5310-06258 REV A & SRM 53-00-51 REPAIR 4 IAW ECRA. THE REPAIR BETWEEN RBL 27 - 33 HAS BEEN APPROVED UNTIL ACFT REACHES 37,500 TOTAL FLIGHT CYCLES.

Source: SDR CALA2014101692440
OTHER · 2014-10-06 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AFT CARGO PIT STATION 1197 + 66 RBL 8 - 18 SHOWS SIGNS OF CORROSION ON UPPER J CHORD. R & R CORD IAW DWG 146T1226 SHEET 1 & SRM 51-40-02.

Source: SDR CALA2014100792380
OTHER · 2014-10-06 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

MAIN CABIN FLOORBEAM STATION 1518 UPPER CAP LBL 1 SHOWS SIGNS OF CORROSION. REPAIRED FLOORBEAM AT STATION 1518 UPPER CAP IAW SRM 53-00-51 REPAIR 2.

Source: SDR CALA2014100792379
OTHER · 2014-10-06 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AC4 CORROSION FOUND ON UPPER SURFACE STATION 1502 RBL 1 - LBL 1 SHOWS SIGNS OF CORROSION. REPAIRED CORROSION FOUND IAW SRM 53-00-51 REPAIR 4. CAT A REPAIR NO FURTHER ACTION NECESSARY.

Source: SDR CALA2014100792378
OTHER · 2014-10-06 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

MAIN CABIN STATION 1562 LBL 54 SHOWS SIGNS OF CORROSION ON UPPER SURFACE. REMOVED DAMAGED SECTION & REPAIRED IAW SRM 53-00-51 REPAIR 1 STATION 1562 LBL 52 - LBL 90.

Source: SDR CALA2014100792382
OTHER · 2014-10-06 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AFT CARGO FLOOR STRUCTURE STATION 1175 LBL 24 - 23 SHOWS SIGNS OF CORROSION. REMOVED & INSTALLED NEW J CHORD IAW DWG 146T1060 & SRM 51-40-02 SHEET 3.

Source: SDR CALA2014100792381
OTHER · 2014-09-28 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FLOORBOARD FASTENER HOLES ARE CORRODED, FOUR EACH UNDER FLOORBOARD P83, RBL 11. MATERIAL REMAINING ON UPPER CHORD AT BS 933, RBL 11 EXCEEDS SRM 53-00-51 DETAIL II LIMITS. REMOVED UPPER CHORD & SEAT TRACK CROWN. FABRICATED & INSTALLED IAW DWG 145T5211 REV L BETWEEN BS 911 TO 1042 AT RBL 11 & IAW SRM 51-40-02.

Source: SDR CALA2014092992348
OTHER · 2014-09-28 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

WEB UNDER STRAP CORRODED IN SEVERAL PLACES AT BS 1197+44, LBL 36 - RBL 45. J CHORD R & R IAW SRM 51-40 -02 & DWG 146T1225.

Source: SDR CALA2014092992347
OTHER · 2014-09-27 Matched by certificate designator
ATA 5322

Part: SHEAR TIE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AREA AFT OF BULK CARGO COMPARTMENT LOWER BILGE FRAME SHEAR TIE IS CORRODED AT BS 1540, STRINGER 39L TO 39R. REMOVED CORRODED SHEAR TIE & FABRICATED A NEW SHEAR TIE IAW DWG 140T2102 REV C. INSTALLED PN 140T2102-607 IAW SRM 51-40-05.

Source: SDR CALA2014092992335
OTHER · 2014-09-27 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

TRANSVERSE FLOORBEAM HAS CORROSION AT FASTENER HOLES APPROX BS 852 & RBL 76. REMOVED CORROSION & FOUND MATERIAL REMOVED EXCEEDS SRM 53-50-51 LIMITS. ORIGINAL THICKNESS IS .120, REMOVED .028, REMAINING IS .092. REMOVED DAMAGED SECTION OF UPPER CHORD. FABRICATED NEW UPPER CHORD, 2 SPLICE ANGELS & FILLER -6 & INSTALLED IAW SRM 53-00-51.

Source: SDR CALA2014092992334
OTHER · 2014-09-18 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

MAIN CABIN FLOORBEAM UPPER SURFACE CORRODED AT BS 325 RBL 36 - 46. REMOVED DAMAGE. MANUFACTURED REPAIR PARTS & INSTALLED REPAIR IAW SRM 53-00-51 REPAIR 1.

Source: SDR CALA2014092292269
OTHER · 2014-09-18 Matched by certificate designator
ATA 5320

Part: SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR STATION 577 RBL 44 PDU SUPPORT CHORD CORRODED UNDER NUTPLATES. REMOVED PDU SUPPORT CHORD, RECEIVED NEW CHORD 143T8236-8, LOCATED, DRILLED & DEBURRED IAW SRM 51-40-05. INSTALLED IAW DWG 143T8201 REV C & SRM 51-40-02.

Source: SDR CALA2014092292262
OTHER · 2014-09-18 Matched by certificate designator
ATA 5320

Part: SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR STATION 520 RBL 44 PDU SUPPORT CHORD CORRODED UNDER NUTPLATES. REMOVED PDU SUPPORT CHORD IAW SRM 51-40-0 2. RECEIVED NEW CHORD PN 143T8236-4. LOCATED, DRILLED & DEBURRED IAW SRM 51-40-05. INSTALLED IAW DWG 143T8201 REV C & SRM 51-40-02.

Source: SDR CALA2014092292264
OTHER · 2014-09-18 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO COMPARTMENT FLOOR FRAME J CHORD CORRODED AT BS 566 RBL 24 & LBL 24. REPLACED J CHORD IAW SRM 51-40-02.

Source: SDR CALA2014092292271
OTHER · 2014-09-18 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

MAIN CABIN FLOORBEAM UPPER SURFACE CORRODED AT BS 303 RBL 50. REMOVED DAMAGE. MANUFACTURED REPAIR PARTS & INSTALLED REPAIR IAW SRM 53-00-51 REPAIR 1.

Source: SDR CALA2014092292268
OTHER · 2014-09-18 Matched by certificate designator
ATA 5320

Part: SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR STATION 580 RBL 30 PDU SUPPORT CHORD CORRODED UNDER NUTPLATES. REMOVED PDU SUPPORT CHORD IAW SRM 51-40-0 2. RECEIVED NEW CHORD PN 143T8236-17. LOCATED, DRILLED & DEBURRED IAW SRM 51-40-05. INSTALLED IAW DWG 143T8201 REV C & SRM 51-40-02.

Source: SDR CALA2014092292265
OTHER · 2014-09-18 Matched by certificate designator
ATA 5320

Part: ANGLE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO COMPARTMENT, CHORD ANGLE CORRODED AT BS 478 - 632 RBL 29.5. REPLACED CHORD IAW SRM 51-40-02.

Source: SDR CALA2014092292270
OTHER · 2014-09-18 Matched by certificate designator
ATA 5230

Part: SKIN — DENTED (CARGO DOOR) · airframe 94,896 hrs · 14,929 cycles

BULK CARGO DOOR SKIN DENTED 2 PLACES ABOVE EXISTING DOUBLER. DENTS FOUND OUT OF SRM LIMITS. REMOVED DOUBLER & ENCOMPASSED INTO ONE REPAIR, REPAIRED IAW SRM 52-30-01 FIG 201 REPAIR 6. THIS IS A CAT B REPAIR WITH LFEC EXTERNAL INSPECTIONS TO BEGIN AT 30000 PTC & SUBSEQUENT INSPECTIONS EA 3000C THEREAFTER IAW SRM 52-30-01 FIG 201 TBL II. VERIFIED VIA ARL DOOR PN 1466301 SN 459 IS ORIGINAL DOOR, THUS FLIGHT CYCLES KNOWN TO BE SAME AS PTC OF 14929.

Source: SDR CALA2014092292266
INADEQUATE Q C · 2014-09-16 Matched by certificate designator
ATA 5347

Part: STRAP — MECHANIC ERROR (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

SEAT TRACK STRAP HAS A DRILL START NEXT TO REPAIR FASTENER COMMON TO TRANSVERSE FLOORBEAM AT BS 873 & RBL 34. REMOVED TRANSVERSE FLOORBEAM SPLICE REPAIR, FABRICATED UPPER CHORD ANGLE & INSTALLED SPLICE REPAIR IAW SRM 53-00-51. THIS IS A CAT A PERMANENT REPAIR.

Source: SDR CALA2014091892240
OTHER · 2014-09-16 Matched by certificate designator
ATA 5320

Part: STRAP — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

AFT PIT WEB UPPER STRAP IS CORRODED IN SEVERAL PLACES ON FRAME AT BS 1153 LBL 8 TO 37. REMOVED SKIN WEB AT STATION 1153, RBL 15 & DAMAGED FLOOR STRUCTURE. RECEIVED NEW J CHORD PN 146T1060-2 & INSTALLED IAW DWG 146T1204 & SRM 51- 40-05 & 51-40-02 ENTIRE LENGTH & INSTALLED SKIN WEB IAW SRM 51-40-2. THIS IS A CAT A PERMANENT REPAIR.

Source: SDR CALA2014091892242
OTHER · 2014-09-13 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

BS 287 FLOORBEAM CORRODED AT LBL 12. REMOVED CORROSION & HAD MATERIAL LOSS OF .049 INCHES FROM ORIGINAL THICKNESS OF .125 INCHES, EXCEEDING SRM 53-00-51 FIG 101 DETAIL II LIMITS. REMOVED DAMAGED SECTION OF FLOORBEAM, FABRICATED -1 & -2 ANGLE, -3 STRAP & INSTALLED IAW SRM 53-00-51. PERMANENT REPAIR.

Source: SDR CALA2014091892232
OTHER · 2014-09-11 Matched by certificate designator
ATA 5320

Part: STRAP — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

WEB UPPER STRAP IS CORRODED & NUTPLATES AT BS 1197 & 110, RBL 42 - 44. R & R J CHORD AT STATION 1197 & 110, RBL 42 - 44 IAW SRM 51-40-02.

Source: SDR CALA2014091292116
OTHER · 2014-09-10 Matched by certificate designator
ATA 5220

Part: HEATING ELEMENT — CRACKED (OVERWING EXIT) · airframe 94,896 hrs · 14,929 cycles

RIGHT FWD OVERWING INSULATION HEATER ELEMENT CRACKED. REMOVED RT FWD OVERWING EXIT LINER. INSTALLED ON EXIT HATCH & INSTALLED ON ACFT. OPERATIONS TESTED IAW MM 21-45-61.

Source: SDR CALA2014091292114
OTHER · 2014-09-10 Matched by certificate designator
ATA 5220

Part: INSULATION — BURNED (OVERWING EXIT) · airframe 94,896 hrs · 14,929 cycles

LEFT FWD OVERWING EXIT INSULATION IS BURNED AT HEATER ELEMENT. REMOVED LT FWD OVERWING EXIT LINER. INSTALLED ON EXIT HATCH & INSTALLED ON ACFT. OPERATIONS TESTED IAW MM 21-45-61.

Source: SDR CALA2014091292111
OTHER · 2014-09-10 Matched by certificate designator
ATA 5220

Part: HEATING ELEMENT — CRACKED (OVERWING EXIT) · airframe 94,896 hrs · 14,929 cycles

RIGHT AFT OVERWING INSULATION HEATER ELEMENT IS CRACKED. REMOVED RT AFT OVERWING EXIT LINER. INSTALLED ON EXIT HATCH & INSTALLED ON ACFT. OPERATIONS TESTED IAW MM 21-45-61.

Source: SDR CALA2014091292112
OTHER · 2014-09-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FLOORBEAM UPPER CORD FOUND CORRODED NEAR NUTPLATES STATION 1197 & 88 LBL 44 - 41. R & R FLOORBEAM CORD PN 146T1060-1 IAW DWG 146T1227SH1 & SRM 51-40-02. NO FURTHER ACTION NECESSARY.

Source: SDR CALA2014091292109
OTHER · 2014-09-04 Matched by certificate designator
ATA 5320

Part: BEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

TRANSVERSE BEAM UPPER STRAP IS CORRODED UNDER FLOORBOARD P 85 BS 880 LBL 32. REMOVED, FABRICATED & INSTALLED TRANSVERSE BEAM BS 860 - 900 LBL 33.09 IAW SRM 51-40-02 & 53-00-51 FIG 201 REPAIR 3 THIS IS A CATEGORY A REPAIR WITH NO REQUIRED INSPECTIONS OUTSIDE OF NORMAL MPD INSPECTIONS.

Source: SDR CALA2014090892075
OTHER · 2014-09-03 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles

FORWARD CARGO FLOOR WEB CORRODED ON BOTTOM SIDE STATION 610 RBL 24. CORROSION BEYOND SRM LIMITS. REMOVED, DRILLED UP NEW WEB IAW SRM 51-40-05 & DWG 143T5012 REV G.

Source: SDR CALA2014090892073
FLUID LOSS · 2014-05-06 Matched by certificate designator
ATA 2761

Part: SEAL — DAMAGED (SPOILER ACTUATOR) · airframe 93,924 hrs · 14,793 cycles

HYD CTR SYS LOSS OF QTY AT GR EXTENSION. REPLACED LEAKING NR 10 SPOILER ACTUATOR FILTER HOUSING SEAL MM27-61-01. LEAK CHECKED NORMAL & C SYS REPLENISHED.

Source: SDR CALA2014050690972
FALSE WARNING · 2014-03-30 Matched by certificate designator
ATA 2612

Part: WARNING BELL — FALSE ACTIVATION (COCKPIT) · airframe 93,501 hrs · 14,739 cycles

FIRE BELLS SOUNDING WITH NO FIRE INDICATION & UNABLE TO SILENCE.

Source: SDR CALA2014033190716

2013

OTHER · 2013-12-24 Matched by certificate designator
ATA 2910

Part: PRESSURE SWITCH — INOPERATIVE (HYDRAULIC SYS) · airframe 92,551 hrs · 14,611 cycles

LT HYD DEMAND PUMP INOPERATIVE IN AUTO & ON MODE IAW IAHMM. REPLACED LT ENG DRIVEN PUMP LOW PRESS SW IAW AMM 29-11-17. OPERATIONS CHECKED GOOD NO LEAKS. ENG LOW PRESS SW WAS PREVENTING AUTO FUNCTION OF DEMAND PUMP.

Source: SDR CALA2013122693937
WARNING INDICATION · 2013-12-22 Matched by certificate designator
ATA 2750

Part: FSEU — MALFUNCTIONED (TE FLAP) · airframe 92,540 hrs · 14,607 cycles

STATUS MESSAGE FLAP SLAT ELECTRICAL. STAB POSITION CARD M838 & FLAP SLAT ELECTRICAL UNIT AT FAULT. R & R STAB MODULE & FLAP SLAT MODULE IAW 27-51-01, 27-58-01. SYS OPERATIONS CHECKED GOOD. ALSO PERFORMED TEST 30 ALL SYS PASSED.

Source: SDR CALA2013122393891
OTHER · 2013-12-17 Matched by certificate designator
ATA 2300

Part: SDU — FAILED (SATCOM) · airframe 92,476 hrs · 14,598 cycles

SATCOM DOES NOT PASS INSTALL TEST IAW WORK CARD 6-2013-2C. FAILED SDU CH 5 TX & RX FAULT. REPLACED SATCOM SDU IAW MM, CHECKED OK. SOFTWARE VERIFIED CORRECT IAW IPC 31-00-00-99 & DIS 39908.

Source: SDR CALA2013121893777
OTHER · 2013-11-03 Matched by certificate designator
ATA 3460

Part: LIGHT — INOPERATIVE (COCKPIT) · airframe 92,013 hrs · 14,540 cycles

CAPTAINS EXECUTE LIGHT ON FMS IS BURNED OUT.

Source: SDR CALA2013110592661
OTHER · 2013-10-02 Matched by certificate designator
ATA 2520

Part: SHADE — DAMAGED (EMERGENCY EXIT) · airframe 91,652 hrs · 14,499 cycles

LT EMERGENCY EXIT WINDOW SHADE DAMAGED. STOWED IN THE OPEN POSITION. PLACED ON DF0082.

Source: SDR CALA2013100391692
OTHER · 2013-09-25 Matched by certificate designator
ATA 3460

Part: CONTROL PANEL — FAULTY (COCKPIT) · airframe 91,568 hrs · 14,489 cycles

CREW REPORTS RT FLIGHT DIRECTOR INOPERATIVE. DEFERRED IAW MEL. MAINTAIN INSTRUCTION SOURCE SELECT SWITCH IN OPERATIVE POSITION FOR ALL PHASES OF FLIGHT. RT FLT DIRECTOR WAS DEFERRED BEFORE CREW REPORTED MCP PROBLEM. MODE CONTROL PANEL REPLACED. RT FLT DIRECTOR OPERATES NORMAL.

Source: SDR CALA2013092591458
OTHER · 2013-09-25 Matched by certificate designator
ATA 2210

Part: AUTOPILOT SYS — MALFUNCTIONED (COCKPIT) · airframe 91,568 hrs · 14,489 cycles

MODE CONTROL PANEL FREEZES AT POWER TRANSFER & RT FLIGHT DIRECTOR DISAPPEARS. REPLACED MODE CONTROL PANEL IAW AMM & TESTED IAW AMM. FOUND ALL WORKING EXCEPT CENTER AUTO PILOT. DEFERRED CENTER AUTO PILOT IAW MEL 2210C. PERFORMED MCDP TEST FOR FCC LT, RT, BOTH FAULTED NO INFC L,R A-P CTN 1. C FCC FAULTED NO IN FC C A-P CTN 1, NO INFC C MCP A-P ENG DISC, & NO INFC C MCP A- P ARM IN. MCP TEST DISC BAR DID NOT REGISTER UPON CONT TEST.

Source: SDR CALA2013092591433
WARNING INDICATION · 2013-09-22 Matched by certificate designator
ATA 7830

Part: MODULE — FAULTY (THRUST REVERSER) · airframe 91,561 hrs · 14,488 cycles

R & L REV ISOLATION VALVE EICAS ILLUMINATED WITH THROTTLE QUAD LIGHT ON. REPLACED THRUST REVERSER RELAY MODULE IAW 78-36-03, OPERATIONS CHECKED GOOD.

Source: SDR CALA2013092491392
OTHER · 2013-09-22 Matched by certificate designator
ATA 2432

Part: CHARGER — INOPERATIVE (MAIN BATTERY) · airframe 91,561 hrs · 14,488 cycles

MAIN BATTERY CHARGER INOPERATIVE. R & R MAIN BATTERY & BATTERY CHARGER IAW AMM.

Source: SDR CALA2013092391378
WARNING INDICATION · 2013-09-09 Matched by certificate designator
ATA 4990

Part: SOLENOID VALVE — FAULTY (APU) · airframe 91,419 hrs · 14,469 cycles

LOST ELECTRICAL POWER & APU FAULT EICAS MESSAGE. R&R DEOIL SOLENOID VALVE, OPERATIONS CHECKED GOOD.

Source: SDR CALA2013091191216
WARNING INDICATION · 2013-09-01 Matched by certificate designator
ATA 2121

Part: FAN — FAULTY (E&E BAY) · airframe 91,307 hrs · 14,457 cycles

FORWARD EQUIPMENT BAY EXHAUST FAN STATUS MESSAGE AT GATE WILL NOT ERASE. R & R FORWARD EQUIPMENT BAY EXHAUST FAN, FAN CONTROL CARD M990 & K1009 CONTROL RELAY. EQUIPMENT BAY EXHAUST FAN STATUS MESSAGE CLEARED & SYSTEM OPERATIONS NORMAL.

Source: SDR CALA2013090290933
WARNING INDICATION · 2013-08-21 Matched by certificate designator
ATA 2421

Part: VALVE — INOPERATIVE (RT IDG) · airframe 91,183 hrs · 14,444 cycles

RT INTEGRATED DRIVE GENERATOR VALVE STATUS MESSAGE. RT ENGINE INTEGRATED DRIVE GENERATOR VALVE INOPERATIVE. NIL TIME TO T-S. MEL COMPLIED WITH.

Source: SDR CALA2013082290662
OTHER · 2013-08-14 Matched by certificate designator
ATA 5610

Part: SEAL — LEAKING (CAPTAIN'S WINDOW) · airframe 91,101 hrs · 14,433 cycles

CAPTAIN`S SIDE WINDOW HAS AN AIR LEAK IN AFT UPPER VERTICAL FRAME. FOUND AFT UPPER SEAL DAMAGED. R & R NR 2 CAPT'S OPENABLE WINDOW IAW AMM.

Source: SDR CALA2013081490455
OTHER · 2013-08-12 Matched by certificate designator
ATA 2300

Part: MICROPHONE — DAMAGED · airframe 91,083 hrs · 14,430 cycles

F/O HAND MICROPHONE STRAIN RELIEF PULLED OUT OF PLUG. REPLACED HAND MIC.

Source: SDR CALA2013081390427
FALSE WARNING · 2013-08-08 Matched by certificate designator
ATA 7261

Part: WARNING LIGHT — FALSE ACTIVATION (OIL FILTER) · airframe 91,028 hrs · 14,423 cycles

RIGHT OIL FILTER EICAS CAME ON MOMENTARILY 2-3 TIMES.

Source: SDR CALA2013080990293
OTHER · 2013-08-06 Matched by certificate designator
ATA 7397

Part: CONNECTOR — DIRTY (NR 2 ENG) · airframe 91,004 hrs · 14,420 cycles

RT PIMU MESSAGE, FOUND A CHANNEL RESISTANCE LOW AND FLUCTUATING. FOUND DEBRIS IN CONNECTOR W5J12. CLEANED CONNECTOR AND SECURED. PERFORMED EEC STATIC CHECK IAW MM 71-00-00. OPS CK GOOD

Source: SDR CALA2013080790233
OTHER · 2013-07-28 Matched by certificate designator
ATA 5753

Part: FAIRING — CRACKED (TE FLAP) · airframe 90,896 hrs · 14,406 cycles

FLAP CANOE FAIRING, 571DB HAS 1 INCH CRACK INBD SIDE. PERFORMED PERMANENT REPAIR IAW SRM 57-53-70, 1 PAGE, 103 NOTE A.

Source: SDR CALA2013072990026
WARNING INDICATION · 2013-07-26 Unresolved
ATA 3610

Part: CONTROLLER — FAILED (BLEED SYSTEM) · airframe 90,866 hrs · 14,402 cycles

LEFT ENGINE PRIORITY VALVE EICAS MESSAGE. R & R NR 1 ENGINE PRESSURE REGULATOR VALVE CONTROLLER IAW AMM. ACCOMPLISHED ENGINE IDLE RUN, NO BLEED FAULTS.

Source: SDR UALA2013072605253
WARNING INDICATION · 2013-07-09 Unresolved
ATA 2421

Part: HEAT EXCHANGER — FAILED (LT IDG) · airframe 90,701 hrs · 14,378 cycles

LEFT IDG VALVE STATUS MESSAGE. REPLACED IDG AIR-OIL HEAT EXCHANGER IAW MM. OPS TESTED IAW AMM, TESTED GOOD, IDG OPS NORMAL.

Source: SDR UALA2013071204898
OTHER · 2013-07-09 Unresolved
ATA 4940

Part: SWITCH — FAILED (APU START) · airframe 90,701 hrs · 14,378 cycles

APU START SWITCH DOES NOT SPRING RETURN FROM "START" TO "ON". REPLACED APU START SWITCH AND OPS NORMAL.

Source: SDR UALA2013071204897
WARNING INDICATION · 2013-07-07 Unresolved
ATA 2822

Part: PRESSURE SWITCH — FAILED (BOOST PUMP) · airframe 90,698 hrs · 14,377 cycles

FUEL SYSTEM PRESSURE EICAS MESSAGE, FLT DIVERTED. REPLACED THE LEFT AFT BOOST PUMP PRESSURE SWITCH.

Source: SDR UALA2013070904787
WARNING INDICATION · 2013-07-03 Unresolved
ATA 2822

Part: PUMP — FAILED (LEFT) · airframe 90,635 hrs · 14,370 cycles

LEFT FWD FUEL PUMP EICAS MESSAGE. NO ASSOCIATED PRESSURE LIGHT IN LT FWD FUEL PUMP SWITCH. FOUND P6 CIRCUIT BREAKER FWD BOOST PUMP OPEN. REPLACED LT FWD BOOST PUMP. LEAK AND OPS CHECKED GOOD.

Source: SDR UALA2013070504704
WARNING INDICATION · 2013-06-14 Unresolved
ATA 2133

Part: OUTFLOW VALVE — MALFUNCTIONED (CABIN PRESSURE) · airframe 90,385 hrs · 14,336 cycles

RECEIVED A CABIN ALTITUDE WARNING IN AUTO 1 - CABIN ALTITUDE REACHED 10,000 FT, MANUAL CONTROL AND AUTO 1 OK, NOW CONTROL OK AND AUTO 1 OK. NOW SHOWING GRADUAL CLIMB IN AUTO 1 EVEN THOUGH DIFFERENTIAL PRESSURE IS LESS THAN 8 PSI. CREW SELECTED MANUAL AND RECOVERED CABIN PSI. ACCOMPLISHED LM CALLOUTS ON PTT SEQ 3852009, 3852008 AND 3852001, OPS CHECKED GOOD.

Source: SDR UALA2013061704161
OTHER · 2013-05-09 Unresolved
ATA 2350

Part: AUDIO PANEL — WEAK (COCKPIT) · airframe 90,133 hrs · 14,303 cycles

FIRST OFFICER`S AUDIO PANEL VOLUME WEAK ALL CHANNELS SPEAKER VOLUME OK HEADSET WEAK. REPLACED MINITEL.

Source: SDR UALA2013050903247
OTHER · 2013-05-03 Unresolved
ATA 2450

Part: CIRCUIT BREAKER — TRIPPED · airframe 90,064 hrs · 14,295 cycles

CREW REPORTED CIRCUIT BREAKER G17 ON P11 TRIPPED SHORTLY AFTER TAKEOFF. G17 FOR 1R CSEU AC PWR SUPPLY. RESET NOT ATTEMPTED DUE TO POWER SUPPLY 2R POWERING THE CSEU. RERACK CSEU POWER SUPPLY AND CHECK PINS ALL OK RESET CIRCUIT BREAKER. CIRCUIT BREAKER STAYED IN, NO FAULT BALLS, TEST POWER SUPPLY AS PER MM, ALL OK.

Source: SDR UALA2013050603144
FLUID LOSS · 2013-04-22 Unresolved
ATA 2721

Part: ACTUATOR — LEAKING (RUDDER) · airframe 89,890 hrs · 14,277 cycles

RUNNING HYD LEAKAGE FROM VERTICAL STABILIZER. INDENTIFIED LEAKING COMING FROM RUDDER RATIO ACTUATOR (RRCA) ROD END. RRCA NEED REPLACEMENT REF AMM 27-21-15.

Source: SDR UALA2013042202753
NO TEST · 2013-04-12 Unresolved
ATA 2697

Part: CONTACT — DIRTY (EXTINGUISHER) · airframe 89,823 hrs · 14,270 cycles

AFT CARGO FIRE EXTINGUISHER ARM LIGHT DOES NOT ILLUMINATE DURING FIRE TEST. CLEANED AND RESEATED CONTACTS ON ARM LIGHT. OPS TESTED NORMAL.

Source: SDR UALA2013041502542
OTHER · 2013-04-12 Unresolved
ATA 2560

Part: HOOK AND LOOP — LOOSE (LIFE VEST POUCH) · airframe 89,813 hrs · 14,269 cycles

LIFE VEST POUCH ON CAPT SEAT IS LOOSE. REPLACED VELCRO ALL OPS OK.

Source: SDR UALA2013041202524
WARNING INDICATION · 2013-04-02 Unresolved
ATA 2840

Part: PUMP — FAILED (FUEL SYSTEM) · airframe 89,737 hrs · 14,256 cycles

FUEL CONFIGURATION LIGHT ON DURING CRUISE. ALL PUMPS ON. NO LIGHTS. PERFORMED FUEL PROCESSOR BITE FOUND FAULTS RM DENS SENSOR FAILURE A01, AND RM DENS SENSOR OPEN AT SPAR A01. VERIFIED MFQ OF RT AND LT TANKS TO BE WITHIN LIMITS VIA STICK READINGS AND PER FUELING MANUAL 6-4-2,31. REPLACED DENSITOMETER FOR FAULT HISTORY ONLY , FUEL CONFIG LIGHT SHOULD BE CORRELATED. FUEL PUMP REPLACED.

Source: SDR UALA2013040302178
OTHER · 2013-03-27 Unresolved
ATA 7830

Part: BLOCKER DOOR — DAMAGED (THRUST REVERSER) · airframe 89,653 hrs · 14,245 cycles

NR 1 ENGINE HAS A DAMAGED BLOCKER DOOR ON THE INNER THRUST REVERSER HALF AT THE 4.30 TO 5 O'CLOCK POSITION. REMOVED BLOCKER DOOR AND DRAG LINK PER CDL AND MM78-31-14 AND 15. REPLACED BLOCKER DOOR.

Source: SDR UALA2013032802008
OTHER · 2013-03-25 Unresolved
ATA 7830

Part: LINER — DENTED (THRUST REVERSER) · airframe 89,645 hrs · 14,244 cycles

NR 1 ENGINE INBOARD THRUST REVERSER HALF HAS THREE DENTS IN THE ACOUSTIC LINER IN THE INNER C DUCT. REPAIRED IAW SRM 54-00-01 REPAIR 1 AND 2.

Source: SDR UALA2013032601896
OTHER · 2013-02-26 Unresolved
ATA 2910

Part: CONTROL UNIT — FAILED (HYD PUMP) · airframe 89,313 hrs · 14,199 cycles

ACFT RETURNED TO BLOCKS WITH C1 ELECTRIC HYDRAULIC PUMP INOPERATIVE. NO HYD PRESSURE ON EICAS PAGE. FOUND PUMP TO OPERATE NORMAL FOR ABOUT 10 MINUTES AND THEN SHUTOFF UNCOMMANDED WITH NO UNUSUAL MESSAGES. REPLACED ELCU PER MM 29-11-14. RAN PUMP FOR 30 MINUTES LOADING PUMP WITH FLT CONTROLS AND OPERATION WAS NORMAL.

Source: SDR UALA2013022701195
WARNING INDICATION · 2013-01-25 Unresolved
ATA 7321

Part: PROBE — FAILED (LT ENGINE) · airframe 88,981 hrs · 14,154 cycles

LT ENGINE EEC MODE ILLUMINATED, FLT DIVERTED. REPLACED PT2 TT2 PROBE REF MM 73-21-03 ACCOMPLISHED PT2 SYSTEM LEAK TEST NO14 REF MM 71-0 0-00 AND EEC IDLE TEST NO6 REF MM 71-00-00 ALL CHECKED OK.

Source: SDR UALA2013012500476
WARNING INDICATION · 2013-01-25 Unresolved
ATA 8097

Part: WIRE HARNESS — CHAFED (LT ENGINE) · airframe 88,979 hrs · 14,153 cycles

CREW REPORTED WHEN LEFT ENGINE START SELECTED, CBS D19 (LT ENG START CONT) AND D28 (STBY ENG IND) ON P11. MAINTENANCE FOUND BENT PIN AT CONNECTOR D7982P ON P61 AND DAMAGED WIRES ON START VALVE HARNESS REF WDM80-11-11. FOUND WIRE BUNDLE TO STARTER VALVE CHAFED. ABOUT 2' BEFORE VALVE. PERFORMED TEMP REPAIR IAW SWPM 20-10-13. OPS TESTED OK.

Source: SDR UALA2013012800492
OTHER · 2013-01-25 Unresolved
ATA 8012

Part: START VALVE — FAULTY (LT ENGINE) · airframe 88,972 hrs · 14,152 cycles

WHEN GROUND SELECTED FOR LT ENGINE START, CIRCUIT BREAKER D28 AND D19 TRIPPED. REPLACED LEFT ENGINE START VALVE.

Source: SDR UALA2013012500461
OTHER · 2013-01-07 Unresolved
ATA 7510

Part: ANTI-ICE VALVE — DAMAGED (LT ENGINE) · airframe 88,763 hrs · 14,124 cycles

HMG HAS BEEN DEF IN COMPLIANCE WITH MEL CARD. REPLACED NUMBER 1 ENGINE COWL TAI VALVE REF AMM, NO HELP. ENG ANTI- ICE VALVE REPAIRED AND HMG SYSTEM HAS BEEN RESTORED PER MEL CARD. RAN CHECK & HMG CHECKED NORMAL. PERFORMED LEFT ENGINE ANTI-ICE VALVE TEST AND ALL INDICATIONS NORMAL. LEAK CHECKS GOOD. ALL VALVE INDICATIONS NORMAL DURING TEST.

Source: SDR UALA2013010700079
FLUID LOSS · 2013-01-03 Unresolved
ATA 2910

Part: HYDRAULIC LINE — LEAKING (RT WING) · airframe 88,722 hrs · 14,119 cycles

RIGHT HYDRAULIC SYSTEM QTY READS .81 ON ARRIVAL LHR. HYDRAULIC LINE LEAKING IN AREA BELOW RIGHT INBD SPOILER ACTUATOR. FOUND HYDRAULIC LINE WITH IMPACT DAMAGE. SEE IPC REF 29-11-77-005 ITEM 560. REPLACEMENT TUBE SECTION IAW AMM 20-10-09 REV 75 & GPM 1-0-13-006. TUBE SECTION INSTALLED BMS 7-185 - 21-6-9 CRES STEEL. SWAGE FITTINGS INSTALLED AT 2 LOCATIONS PER GPM 1-0-13-20. LEAK CHECKS ACCOMPLISHED, ALL OPS NOW NORMAL.

Source: SDR UALA2013010400051

2012

OTHER · 2012-11-13 Unresolved
ATA 5720

Part: HINGE — BROKEN (LT WING) · airframe 88,481 hrs · 14,083 cycles

LEFT WING THERMAL ANTI-ICING DUCT SEAL DOOR ASSY AFT HINGE BROKEN AND AFT OUTBD. CORNER OF PANEL SHEET METAL TORN. REMOVED DAMAGED DOOR ASSEMBLY AND HARDWARE AND PLACED IN BULK PIT. REMOVED DAMAGED ERODED EDGE STRIP AND APPLIED LAY-UP REPAIR PER SRM 57-41-01, RPR 2. REPLACED HINGES AND RE-INSTALLED TAI DOOR PER MM. DOOR ADJUSTMENT CHECKS GOOD PER MM. RESTORED ACFT TO NORMAL CONDITION.

Source: SDR UALA2012111306537
OTHER · 2012-11-12 Unresolved
ATA 5754

Part: SKIN — CRACKED (LE SLAT) · airframe 88,481 hrs · 14,083 cycles

LEFT WING NR 5 LEADING EDGE SLAT HAS A CRACK IN THE LOWER SURFACE OF THE SLAT SKIN AT THE TAB INBOARD OF THE ANTI ICING DOOR ASSEMBLY. CRACK STARTS AT AFT EDGE OF TAB AND EXTENDS 1 INCH TO RIVET. COMPLIED WITH SRM 57-43-01 PAGE 104 ITEM P. ALL ITEMS IN AREA ARE SECURED. REMOVED DAMAGED PLIES AND BOND NEW REPAIRS 2 IAW SRM APPLIED CONDUCTIVE COAT MM RESTORED FINISH.

Source: SDR UALA2012111306538
OTHER · 2012-11-10 Unresolved
ATA 5250

Part: PRESSURE SENSOR — DEFECTIVE (COCKPIT DOOR) · airframe 88,465 hrs · 14,080 cycles

FLT DECK DOOR CKT BREAK POPPED. TROUBLESHOT SYSTEM FOUND PRESSURE SENSOR BAD. INSTALLED ROBBED SENSOR. GROUND FUNCTIONAL TEST NORMAL IAW WD 52-51-11. NEW SENSOR ON AOG L4650 RESET CB NORMAL.

Source: SDR UALA2012111206510
FLUID LOSS · 2012-10-22 Unresolved
ATA 2230

Part: COMPUTER — FAULTY (AUTOTHROTTLE SYS) · airframe 88,220 hrs · 14,046 cycles

LT ENG HYD LEAK, FLIGHT DIVERTED. CREW REPORTS AUTOTHROTTLE DISCONNECT. WOULD NOT RESET. REPLACED THRUST MANAGEMENT COMPUTER PER MM. HYDRAULIC L ENG PUMP SUPPLY CB POPPED. LOCATION OVHD PANEL D29. LEFT ENG HYD SHUT-OFF VALVE IS LEAKING AT UPPER MATING FLANGE. INSTALLED NEW O-RINGS ON UPPER AND LOWER MATING FLANGES, LEAK CHECK OK. REPLACED LEFT ENG HYD SHUTOFF VALVE PER AMM, OPS CHECK GOOD.

Source: SDR UALA2012102306076
OTHER · 2012-09-20 Unresolved
ATA 2710

Part: TRANSMITTER — FAULTY (LT AILERON) · airframe 87,900 hrs · 13,993 cycles

INBOARD AILERONS DO NOT EXTEND SYMMETRICALLY WHEN FLAPS ARE LOWERED; RT SIDE DROPS LOWER. FOLLOWED FIM 27-18-00 FIG 106 FOR INDICATOR FAILS TO RETURN TO ZERO WITH CONTROL WHEEL ZERO. FOLLOW "NO" ON DIAGRAM AND NEXT STEP STATES TO EXAMINE AILERON CABLE SYSTEM. REMOVED AND REPLACED LEFT INBOARD AILERON POSITION TRANSMITTER REF MM27-18-10 AND MM 27-18-00 RIG PINS AS1 AND AS2 INSTALLED FOR RIGGING PINS REMOVED AFTER COMPLETION OF TRANSMITTER REPLACEMENT.

Source: SDR UALA2012092105368
FALSE WARNING · 2012-09-06 Unresolved
ATA 2751

Part: TRANSMITTER — FAULTY (TE FLAP) · airframe 87,738 hrs · 13,972 cycles

FLAP SLAT ELEC STATUS MSG. DUE TO REPEAT FLAP SLAT ELEC STATUS EICAS MESSAGES AND NOTHING FOUND WHEN BITING THE FSEU, INSTALL A -63 FSEU PCN 481-9266 PER MM. CREATED A CF ITEM STATING THAT THE -63 IS INSTALLED AND TO BE REMOVED AT A LATER DATE. REPLACED FSEU BOX. FOUND NR 8 FLAP POS TRANSMITTER OUT OF RANGE, PER MM. READING 226.45 SHOULD READ APPROX 47.57. REPLACED NR 8 FLAP POS TRANSMITTER TARGET 47.48. NOW WITHIN LIMITS PER MM. OPS CHECK FLAP SEVERAL TIMES, OPS NORMAL.

Source: SDR UALA2012090605034
OTHER · 2012-09-01 Unresolved
ATA 2422

Part: INVERTER — FAULTY (NR 1) · airframe 87,664 hrs · 13,963 cycles

STANDBY INVERTER STATUS MESSAGE . REPLACED STANDBY INVERTER IAW MM.

Source: SDR UALA2012090404978
OTHER · 2012-08-14 Unresolved
ATA 3797

Part: WIRE — CHAFED (VACUUM BLOWER) · airframe 87,444 hrs · 13,937 cycles

AFT VACUUM BLOWER (LAV SYS 1) CIRCUIT BREAKER POPPED. TROUBLESHOT AS PER WD 38-32-11. FOUND NO POWER AT PINS 2 AND 3 ON D1266, HAVE 115V AC AT PINS 22 2 0 24 ON D6314 NEED TO CHECK FROM D1266 BACK. NO FURTHER TIME DUE TO AC MOVEMENT BLOWER SYSTEM DEACTIVATED AS PER MEL CP PULLED. FOUND CHAFED WIRES W1354 -017-12 AND W1354-001-16 REF WDM 38-32-11 AND 21-26-11. REPAIRED WIRES WITH A SEALED SPLICE AT STA. 1550 FWD OF CABIN PRESSURE OUTFLOW VALVE (V15) PER SWPM 20-10-13 AND 20-30-12. OPS CHECK GOOD.

Source: SDR UALA2012081604551
OTHER · 2012-07-23 Unresolved
ATA 3610

Part: DUCT — DAMAGED (APU COOLING) · airframe 87,178 hrs · 13,900 cycles

APU COOLING AIR DUCT DAMAGED. REPLACED COOLING AIR DISCHARGE DUCT AND SECURED WITH CLAMPS PER AMM.

Source: SDR UALA2012072303982
OTHER · 2012-07-21 Unresolved
ATA 4990

Part: PRESSURE SWITCH — FAILED (APU OIL) · airframe 87,163 hrs · 13,898 cycles

LOW OIL PRESSURE SWITCH FAULTED. REPLACED LOW OIL PRESSURE SWITCH RAN APU. APU AUTO SHUTDOWN AFTER 90 SEC.

Source: SDR UALA2012072303992
OTHER · 2012-07-21 Unresolved
ATA 4960

Part: CONTROL UNIT — FAULTY (APU) · airframe 87,163 hrs · 13,898 cycles

APU AUTO SHUTDOWN AT THE GATE. REPLACED CONTROL UNIT PER MM. OPERATED APU PER JRH 2-6-15 WITH PNEUMATIC AND ELEC LOAD APPLIED. RUNS NORMAL.

Source: SDR UALA2012072303985
OTHER · 2012-07-19 Unresolved
ATA 4990

Part: FILTER — FAULTY (APU OIL) · airframe 87,148 hrs · 13,896 cycles

FOUND APU GENERATOR LUBE SYSTEM FILTER DIFFERENTIAL PRESS IND POPPED. REPLACED APU GENERATOR LUBE SYSTEM FILTER AND RESET DIFFERENTIAL PRESSURE INDICATOR.

Source: SDR UALA2012072303994
OTHER · 2012-07-18 Unresolved
ATA 4990

Part: PRESSURE SWITCH — FAILED (APU OIL) · airframe 87,148 hrs · 13,896 cycles

APU AUTO SHUTDOWN. APUC BITE TEST SHOWED LOP. REPLACED LOW OIL PSI SWITCH. REPLACED APU DEOIL SOLENOID AND FLOW SENSING MODULE-NO HELP. FOUND DIFFERENTIAL PRESS IND POPPED FOR GENERATOR LUBE FILTER.

Source: SDR UALA2012071903934
FLAME/FIRE · 2012-07-09 Unresolved
ATA 3240

Part: BRAKE — FIRE (LT MLG) · airframe 87,025 hrs · 13,881 cycles

LEFT MAIN GEAR AFT INBD BRAKE TEMP WENT TO 7. GROUND CREW NOTED FLAME AND DISCHARGED POWDER TYPE FIRE EXTINGUISHER. TIRE FUSE DID NOT RELEASE. CDG FIRE DEPT WAS CALLED AND SPRAYED WATER ON LEFT MAIN BRAKES. WHEEL AND BRAKE REPLACED LEFT MAIN GEAR AFT INBD POSITION.

Source: SDR UALA2012071103700
OTHER · 2012-07-03 Unresolved
ATA 5730

Part: ACCESS PANEL — OUT OF ADJUST (LT WING) · airframe 86,940 hrs · 13,869 cycles

LEFT WING FUELING PANEL WILL NOT STAY OPEN. SUPPLEMENTAL DATA, FUELING PANEL DOOR HOLD OPEN EYELET ADJUSTED TO SIT CORRECTLY IN RETAINING HOLE. NOW OPERATES NORMALLY.

Source: SDR UALA2012070503600
FLAME/FIRE · 2012-06-28 Unresolved
ATA 3241

Part: BRAKE — FIRE (MLG) · airframe 86,866 hrs · 13,859 cycles

HOT BRAKES, RAMP SAW FLAMES COMING FROM BRAKE. ACCOMPLISHED INSPECTION MM.

Source: SDR UALA2012070203512
WARNING INDICATION · 2012-05-10 Unresolved
ATA 2160

Part: VALVE — MALFUNCTIONED (CABIN TEMP) · airframe 86,220 hrs · 13,778 cycles

UNABLE TO CONTROL CABIN TEMP. CYCLED CB C33 PER TOMC AND REGAINED CAB TEMP CONTROL. FOUND MID TRIM MODULATING VALVES IN OPEN POSITION. AS PER DF0690 CLOSED AUX MID AND MID MODULATING VALVES.

Source: SDR UALA2012051102755
OTHER · 2012-03-23 Unresolved
ATA 5730

Part: PANEL — DAMAGED (LT WING) · airframe 85,619 hrs · 13,700 cycles

LEFT WING FIXED T/E UPPER OTBD PANEL HAS DAMAGE. REF IPC 57-51-65-002 REMOVED AND ROUTED TO SHOP 273 FOR DELAM REPAIR ON R62260.

Source: SDR UALA2012032601906
OTHER · 2012-03-15 Unresolved
ATA 5730

Part: PANEL — DAMAGED (LT WING) · airframe 85,607 hrs · 13,698 cycles

LT WING PANEL ISSUE, FLIGHT DIVERTED. THE L/E IS UP INTO THE AIRSTREAM APPROX 2-3 INCHES. NO CONTROL OR VIBRATION PROBLEMS. REMOVED PANEL. REPAIRED IAW EC-RA NR 5700-03044

Source: SDR UALA2012031501721
SMOKE/FUMES/ODORS/SPARKS · 2012-03-06 Unresolved
ATA 2597

Part: CABLE — SHORTED (CABIN) · airframe 85,484 hrs · 13,683 cycles

P62 PIGTAIL SPARKS WHEN DISCONNECTED. COLLARED CB. REPLACED SHORTED PIGTAIL CABLE AND RESET C-B.

Source: SDR UALA2012030601427
WARNING INDICATION · 2012-01-19 Unresolved
ATA 2750

Part: CONTROL UNIT — FAULTY (FLAP/SLAT) · airframe 84,874 hrs · 13,603 cycles

FLAP-SLAT MSG. TRBLSTG PER FIM. NEW FSEU, NO HELP. FAULTING M548 OTBD SLAT POS XDCR. ON AOG, E5555 ETA 0450. DMM 0240. REPLACED FSCU PER MM. SYSTEM OPERATED NORMAL. NO EICAS OR STATUS MSG. PRESENT.

Source: SDR UALA2012011900412
NO WARNING INDICATION · 2012-01-02 Unresolved
ATA 7421

Part: IGNITER — FAILED (NR 2 ENGINE) · airframe 84,636 hrs · 13,574 cycles

NO EGT RISE ON RT ENG WITH NR 2 IGNITION START OK ON BOTH IGNITORS. REPLACED NR 2 IGNITER PLUG IAW MM, ENGINE STARTED OK PER JRH 2-6-1.

Source: SDR UALA2012010300042
OTHER · 2012-01-01 Unresolved
ATA 2297

Part: WIRE — BROKEN (FCC) · airframe 84,626 hrs · 13,573 cycles

CENTER FCC FAILS INTERFACE TEST 04. FOUND WIRE W011-770-22 BROKEN AT CONNECTOR D479. REPINNED WIRE REF BOEING STANDARD PRACTICES MANUAL 20-10-13. CTR FCC TEST NORMAL. ACP CAT III TEST PER MM, TEST PASSED. AIRCRAFT RETURNED TO CAT III STATUS

Source: SDR UALA2012010300060

2011

OTHER · 2011-12-30 Unresolved
ATA 2211

Part: SELECTOR KNOB — BROKEN (HEADING) · airframe 84,606 hrs · 13,571 cycles

HEADING SELECT KNOB BROKEN BUT USEABLE. REPLACED MCP PER MM.

Source: SDR UALA2012010300059
OTHER · 2011-12-19 Unresolved
ATA 5730

Part: PANEL — LOOSE (RT WING) · airframe 84,492 hrs · 13,555 cycles

FOUND DURING WALK AROUND THE RT ANTI-ICE DUCT FAIRING PANEL JUST OUTSIDE OF THE ENGINE REAR PART HANGING DOWN. REMOVED PER CDL 57EE. DOOR ASSY IS LOST. REPLACED PANEL.

Source: SDR UALA2011121906930
WARNING INDICATION · 2011-12-05 Unresolved
ATA 2161

Part: CONTROLLER — FAULTY (CABIN) · airframe 84,311 hrs · 13,532 cycles

AFT CABIN TEMP EICAS MESSAGE WITH INOP LIGHT ON. RESET ZONE TEMP CONTROLLER - NO HELP. CW MEL. REPLACED ZONE TEMP CONTROLLER PER MM, OPS CHECK GOOD. NO EICAS MESSAGES OR FAULTS.

Source: SDR UALA2011120606720
OTHER · 2011-11-11 Unresolved
ATA 2497

Part: WIRE — DAMAGED (GENERATOR SYS) · airframe 84,062 hrs · 13,499 cycles

CREW ABORTED TAKEOFF AT APPROXIMATELY 80 KNOT DUE TO NR 1 GEN DRIVE LIGHT AND ASSOCIATED EICAS MSG. ACCOMPLISH HIGH ENERGY STOP CHECK PER MM 05-51-14 201. ITEM ROLLED FORWARD. ACP'D INSP PER AMM. NO DEFECTS NOTED. DUE TO RECENT REPORTS OF THE NR 1 ENG IDG DRIVE LIGHT COMING ON DURING TO ROLL, AFTER REPAIR TO AFFECTED IDG WIRING. RUN ENGINE AT HIGH POWER FOR A MINIMUM OF 10 MINUTES TO VERIFY POSITIVE FIX. ACCOMPLISHED HIGH PWR RUN NR 1 ENG PER LM CALLOUT. VOLTS AN FREQS WITHIN LIMITS PER JRH 2-6- 5. TEMPS NORMAL, NO FLUCTUATIONS OR ABNORMALITIES NOTED. WITH NR 1 IDG CARRYING ALL LOADS, ALL OPS NORMAL AS ABOVE.

Source: SDR UALA2011111106162
OTHER · 2011-09-20 Unresolved
ATA 2915

Part: PRESSURE SWITCH — FAULTY (FUEL PUMP) · airframe 83,409 hrs · 13,409 cycles

LEFT HYD DEMAND PUMP FAILED TO OPERATE IN AUTO WITH ENGINE OFF. WORKS OK IN ON POSITION. -RDF-T :RPL S27 ELEC HYD PUMP L CONTROL PRESSURE SWITCH, NO HELP. REPLACED RELAYS K130, K134, & K131 NO HELP. REPLACED L DEMAND PUMP SWITCH ASSY S5, NO HELP. CHECKED WIRING BETWEEN RELAYS K130, K131 AND S25, S26 AND S27 OK REF WDM 29-11-12. REPLACE ENG PUMP LT PRESS SWITCH S26. OPS CHECK NORMAL.

Source: SDR UALA2011092005081
OTHER · 2011-09-20 Unresolved
ATA 2310

Part: TRANSCEIVER — WEAK (HF COMM) · airframe 83,409 hrs · 13,409 cycles

HF TRANSMISSION AND RECEPTION ARE INOP, WEAK,GARBLED INTERMITTENT, ETC AT ALL CREW STNS. (1 = L HF, 2 = R HF). MAINT TEXT: LEFT HF INOP PER CREW. NO TIME TO TROUBLESHOOT. COMPLIED WITH MEL. REPLACED LEFT HF TRANSCEIVER PER AMM, OPS CHECKS GOOD.

Source: SDR UALA2011092005080
OTHER · 2011-08-30 Unresolved
ATA 2140

Part: CONTROL VALVE — FAULTY (CARGO HEAT) · airframe 83,153 hrs · 13,374 cycles

AFT CARGO OVERHEAT LIGHT ON. REPLACED AFT CARGO HEAT CONTROL VALVE PER MM, OPS CHECKED NORMAL.

Source: SDR UALA2011083104675
OTHER · 2011-08-02 Unresolved
ATA 5350

Part: FAIRING — MISSING (FUSELAGE) · airframe 82,803 hrs · 13,321 cycles

DURING RAMP CHECK FOUND PANEL MISSING ON AFT TOP OF RIGHT LANDING GEAR BODY DOOR AREA. ACCOMPLISH REPAIRS PER EVA 81169. RT WING MLG SIDE STRUT SWIVEL FAIRING ASSEMBLY TEMPORARY FAIRING INSTALLED AS PER EVA-8 1169. VERIFICATION REQUIRED BEFORE EACH FLIGHT FOR SECURITY OR DEFORMATION ALSO RIGHT MAIN LANDING GEAR SHOCK STRUT DOOR VERIFICATION RQRS EVERY FLT FOR DAMAGE. THIS FAIRING IS LOCATED UNDER THE WING JUST FORWARD OF THE RIGHT MLG SIDE STRUT SWIVEL.

Source: SDR UALA2011080304013
NO TEST · 2011-07-21 Unresolved
ATA 2710

Part: AILERON SYS — BINDING (LEFT) · airframe 82,728 hrs · 13,308 cycles

CREW REPORTS DURING THE FLIGHT CONTROL CHECK BOTH CAPT AND F/O FELT BINDING IN THE LEFT AND RIGHT AILERON CONTROL CHECK. AILERON CONTROL BINDING. MM INSPECTED CABLES AND BEARINGS PER MM. LUBED LEFT FEEL AND CTR MECH AND LEFT OUTBOARD AILERON PER MM. DISCONNECTED AND RECONNECTED RODS TO L,R,C LCCA. DISCONNECTED AND RECONNECTED BUS BAR BETWEEN CAPTS AND F/O COLUMN. DISC AND REFITTED SPOILER RVDT & FL FRCE TRNS. WHEN CAPTAINS COLUMM GETS TO 6.5 UNITS BEARING IN COLUMN OR DRUM HAS FLAT SPOT WITHIN LIMITS PER MM. REF WHEEL FORCE CHECK PER MM. TORQUE IS BETWEEN 65-104 POUNDS INCHES AND ACTUAL READING NEVER EXCEEDED 80 LBS INCHES.

Source: SDR UALA2011072203733
OTHER · 2011-07-19 Unresolved
ATA 5220

Part: FITTING — MISSING (CABIN) · airframe 82,705 hrs · 13,304 cycles

STRANGE NOISE AROUND ROW 19A. SOUNDS LIKE OBJECT FLAPPING IN WIND STREAM CLOSE TO FUSELAGE. FOUND LEFT AFT OVERWING DOOR STEP CHORD DISCONNECTED, REPLACED MISSING CIRCLIP AND SECURED CHORD TO STEP, ALL CHECKS NORMAL.

Source: SDR UALA2011071903655
OTHER · 2011-05-24 Unresolved
ATA 2297

Part: WIRE — BROKEN (AUTOPILOT) · airframe 82,176 hrs · 13,219 cycles

MCP FAULT. FOUND AUTOPILOT ANNUNCIATOR LIGHT L19 FAULTING. TRIED GOOD UNIT FCC L & R PASSED TEST 1. C FCC FAULTING NO INFC FCC C MCP A-P EN G DISC AND NO INFC FCC C MCP A-P ARM IN. PER FIM 28 V DC PRESENT AT PINS 7 ALL CONNECTORS. ACCOMPLISHED WIRING CHECKS PER WDM. FOUND BROKEN WIRE AT MCP CONNECTOR D479 PIN 30 WIRE W011-770-22. REPLACED THE CONTACT PIN AND ACCOMPLISHED CAT III GROUND CHECK PER MM, SYS CHECKED OK. REPLACED MODE CONTROL PANEL & C FCC COMPUTER REF MM.

Source: SDR UALA2011052402535
SMOKE/FUMES/ODORS/SPARKS · 2011-05-01 Unresolved
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 81,867 hrs · 13,176 cycles

CREW REPORTS BURNING RUBBER SMELL AT ROWS 31 TO 33. CALL LIGHT ON AT SEAT 33C WITHOUT CALL BUTTON, SEAT VIDEO 33C WENT BLANK AND SMELL DISSIPATED. CREW REPORTED CALL LIGHT WAS ABLE TO BE RESET. CHECKED VICINITY OF ROWS 31C THRU 33C ALL PCU AND VIDEO FUNCTIONS NORMAL. NO BURNING ODOR NOTICED.

Source: SDR UALA2011050202129
OTHER · 2011-04-14 Unresolved
ATA 7314

Part: PUMP — DEFECTIVE (NR 1 ENGINE) · airframe 81,638 hrs · 13,142 cycles

NR 1 ENG FUEL PUMP NEEDS TO BE OP AND LEAK CHECKED. FUEL PUMP CHANGED BY AMT. PERFORM IDLE RUN TO OPS CHK FUEL FILTER CONNECTOR NR 1 ENGINE. ACP'D FIVE MINUTE IDLE NR 1 ENGINE, OPS CHK OKAY. NO MESSAGES.

Source: SDR UALA2011041801886
OTHER · 2011-04-14 Unresolved
ATA 7397

Part: CONNECTOR — LOOSE (NR 1 ENGINE) · airframe 81,638 hrs · 13,142 cycles

NR 1 ENG MAIN FUEL FILTER SENSOR CANNON PLUG IS LOOSE. REPLACED CONNECTOR D10996.

Source: SDR UALA2011041501842
OTHER · 2011-04-10 Unresolved
ATA 5321

Part: FLOOR PANEL — CRACKED (ROW 20 RT) · airframe 81,587 hrs · 13,133 cycles

AROUND ROW 20 RT FLOOR SOFT HAS SLIGHT INDENTATION. FLOOR PANEL HAS 18 IN CRACK DOWN CENTER. ACCOMPLISHED INTERIM REPAIR IAW EVA 80757.

Source: SDR UALA2011041101758
OTHER · 2011-04-02 Unresolved
ATA 2820

Part: PRESSURE SENSOR — FAILED (FUEL SYSTEM) · airframe 81,476 hrs · 13,116 cycles

L FUEL OVERRIDE PUMP CIRCUIT BREAKER IS OUT. MEL COMPLIANT. REPLACED LEFT OVERRIDE PUMP PER AMM. NO PUMP PRESSURE. CHECKED PRESSURE SWITCH, OVERRIDE PUMP FOUND FAILED. REPLACED PCN AS PER MM. OP'S NORMAL NOW.

Source: SDR UALA2011040401611
WARNING INDICATION · 2011-03-21 Unresolved
ATA 2910

Part: RELAY — FAULTY (HYDRAULIC SYS) · airframe 81,315 hrs · 13,092 cycles

LEFT HYD ELEC DEMAND PUMP IN AUTO CAUSES PRESS AND SYS PRESS LTS TO ILLUMINATE. WORKS IN ON. DEFERRED LEFT HYD ELEC DEM AND PUMP AUTO FUNCTION IAW MEL. REPLACED K130 RELAY. LEFT HYD DEMAND PUMP OPERATES NORMAL IN AUTO.

Source: SDR UALA2011032101339
NO TEST · 2011-03-19 Unresolved
ATA 3350

Part: HOLDER — DEFECTIVE (CABIN) · airframe 81,293 hrs · 13,088 cycles

RT OVERWING SLIDE AFT EMERGENCY LIGHT INOPERATIVE. REPLACED LAMPHOLDER ASSY PER MM, OP CHECKS NORMAL.

Source: SDR UALA2011032101329
NO TEST · 2011-03-19 Unresolved
ATA 3397

Part: CONNECTOR — UNSECURE (CABIN) · airframe 81,293 hrs · 13,088 cycles

FWD GALLEY CROSSAISLE EEL LIGHT STRIP INOP. SECURED POWER FEEDER CONNECTOR, OPS CHECKED OK.

Source: SDR UALA2011032101348
FLUID LOSS · 2011-02-27 Unresolved
ATA 2721

Part: ACTUATOR — LEAKING (RUDDER) · airframe 81,048 hrs · 13,051 cycles

HYD LEAK COMING FROM VERTICAL STABILIZER MID AREA. SWING RUDDER BACK AND FORTH, WITH RIGHT HYD SYSTEM,LEAK INTENSIFED. REPLACED RT RUDDER PCA REF MM.

Source: SDR UALA2011022800965
OTHER · 2011-02-23 Unresolved
ATA 7200

Part: HEAT SHIELD — BROKEN (NR 2 ENGINE) · airframe 81,030 hrs · 13,046 cycles

REPLACED THE OIL TANK HEATSHIELD ON NR 2 ENGINE DUE TO LOWER SECTION BROKEN AND SEPARATING, WHICH HAS DAMAGED THE WIRE BUNDLE BELOW. REPLACED NR 2 OIL TANK HEAT SHIELD IAW MM.

Source: SDR UALA2011022500956
WARNING INDICATION · 2011-02-22 Unresolved
ATA 2421

Part: IDG — FAULTY (NR 2) · airframe 81,028 hrs · 13,045 cycles

RIGHT IDG DRIVE LIGHT CAME ON STEADY DURING CLIMB AT APPROX 10,000 TO 12,000 FT. WHEN THE DRIVE LIGHT CAME ON IT WAS ACCOMPANIED BY A VIBRATION. WHEN THE IDG WAS DISCONNECTED THE VIBRATION ENDED. REPLACED OVHD PUSH BUTTON SWITCH & RT IDG.

Source: SDR UALA2011022200899
OTHER · 2011-02-21 Unresolved
ATA 2421

Part: HEAT EXCHANGER — FAULTY (IDG OIL) · airframe 81,027 hrs · 13,044 cycles

DUE TO HISTORY OF RT IDG DRIVE LIGHT ON IN FLIGHT AND POSSIBLE FUEL CONTAMINATION AT TERMINATION OF FLT REPLACE IDG AIR-OIL HEAT EXCHANGER AND VALVE. (HEAT EXCHANGER AND VALVE SHOULD BE REPLACED AS AN ASSY). AIR OIL COOLER REPLACED IAW MM.

Source: SDR UALA2011022200898
INADEQUATE Q C; WARNING INDICATION · 2011-02-19 Unresolved
ATA 2421

Part: IDG — OVERSERVICED (RT GENERATOR) · airframe 81,026 hrs · 13,043 cycles

RT IDG DRIVE LIGHT, RTFL. CAME ON RT AFTER TAKEOFF. CREW REDUCED POWER AT 10,000 AND THE DRIVE LIGHT WENT OUT. CREW STARTED CLIMB & AT 12,000 FT, DRIVE LIGHT CAME BACK ON AND WOULD NOT GOT OUT. CREW DISCONNECTED IDG. CHECKED OIL LEVEL IN RIGHT IDG AFTER LANDING AND NOTIFIED SAMC 767 MAINT. CONTROLLER WITH FINDINGS. FOUND OVERFILLED BY 1 QUART.

Source: SDR UALA2011022100854
WARNING INDICATION · 2011-02-19 Unresolved
ATA 2421

Part: IDG — OVERSERVICED (RT GENERATOR) · airframe 81,025 hrs · 13,042 cycles

RT ENG IDG EICAS, RTFL. RIGHT IDG DRIVE LIGHT ILLUMINATED ON CLIMB. CREW REDUCED THE POWER ON THE RIGHT ENGINE AND THE DRIVE LIGHT WENT OUT. AT THIS TIME THE IDG IS NOT DISCONNECTED. FOUND IDG OVERSERVICED. REPLACED NR 2 ENG IDG. REPLACED NR 2 ENG IDG DRIVE OIL SEAL. RAN ENGINE AT HIGH POWER. SYS CHECKS GOOD. NO OIL LEAKS NOTED.

Source: SDR UALA2011022100853
WARNING INDICATION · 2011-02-18 Unresolved
ATA 2421

Part: IDG — FAULTY (RIGHT) · airframe 81,025 hrs · 13,041 cycles

RT GEN DRIVE LIGHT ON AND CREW DISCONNECTED GEN. FOUND RT IDG OVER SERVICE DRAINED 1.5 QTS. REPLACED RT GCU IAW MM. RAN BOTH ENGS FOR 5 MIN IAW JRH, ALL INDICATION ARE NORMAL, AFTER RUN CHECK IDG OIL SERVICE, FOUND NORMAL.

Source: SDR UALA2011022200897
WARNING INDICATION · 2011-02-17 Unresolved
ATA 2421

Part: IDG — FAULTY (RT GENERATOR) · airframe 81,016 hrs · 13,040 cycles

CREW REPORTS RT GENAERATOR DRIVE LIGHT ILLUMINATED. CREW DISCONNECTED RT GENERATOR. RT ENGINE IDG REPLACED. IDLE RUN ACCOMPLISHED BY CREW, GENERATOR OPS NORMAL. IDG SERVICED WITH 2197 OIL.

Source: SDR UALA2011021700830
OTHER · 2011-02-11 Unresolved
ATA 3411

Part: PROBE — LEAKING (PITOT STATIC) · airframe 80,974 hrs · 13,034 cycles

LOUD SQUEAL FROM BEHIND CAPT INST PANEL - REPEAT. TROUBLESHOT AND FOUND LT UPPER AND LOWER PITOT PROBE LEAKING, LT TAT PROBE AND RADOME HINGE ATTACHMENT BOLTS LEAKING. SEALED AS REQUIRED. PERFORMED LEAK CHECK, NO LEAKS NOTED.

Source: SDR UALA2011021100740
OTHER · 2011-01-09 Unresolved
ATA 3610

Part: BONDING JUMPER — BROKEN (BLEED AIR SYS) · airframe 80,699 hrs · 12,993 cycles

NR 1 ENG HPSOV BONDING JUMPER BROKEN AT LUG. REPLACED BROKEN BONDING JUMPER ON HPSOV AND SAME ON HP-IPSOV.

Source: SDR UALA2011011000134
WARNING INDICATION · 2011-01-09 Unresolved
ATA 2913

Part: VALVE — INOPERATIVE (HYD PUMP) · airframe 80,699 hrs · 12,993 cycles

ON SHORT FINAL HAD C HYD DEM PUMP EICAS AND PUMP PRESSURE LIGHT 2 TIMES FOR ABOUT 10 SECONDS EACH. CENTER ADP PUMP HAS BEEN RENDERED INOP PER MEL. FOUND HPSOV BITE FAILS. REPLACED NR 1 HPSOV IAW MM.

Source: SDR UALA2011011000135

2010

WARNING INDICATION · 2010-12-15 Unresolved
ATA 3097

Part: CONNECTOR — FAILED (WINDOW HEAT) · airframe 80,398 hrs · 12,946 cycles

WINDOW MESSAGE DISPLAYED ON EICAS. INOP LGT ILLUM. INOP LGT EXTINGUISHED WHEN SW WAS RECYCLED TO OFF THEN ON. POSN 4 (1=L FWD, 2=L SIDE,3=R FWD,4=R SIDE) FRM 30 41 01. CREW COMMENTS: LT SIDE WINDOW HEAT FAILED 3X - RESET EACH TIME FOR SEVERAL HOURS. REPLACED WHC M192 IAW MM, CKD WINDOW CONNECTORS, CKD BENCH PLUG WHC, OPS CHECKED OK.

Source: SDR UALA2010121604594
FALSE WARNING · 2010-12-12 Unresolved
ATA 3417

Part: ADC — FAULTY (LEFT) · airframe 80,349 hrs · 12,938 cycles

CAPTAIN ALT CONSTANTLY MOVES UP AND DOWN 60' AT CRUISE. ALSO TEMPORARILY WENT UP IN DESCENT. ALL FLIGHT CONTROLS FELT UNUSUALLY HEAVY ON FINAL AND LANDING. IAW CREW HEAVY FORCES WERE NOTICED ON AIL AND ELEV. LT ADC REPLACED. ACP BITE CHK OF ALL CSEU UNITS. ACP CK OF MCDP NO LAST FLT FAULTS. ACP LM6996 ALL CONTROL MOVEMENTS NORMAL & VISUAL CHECK OF VISIBLE CABLES & QUADRANTS NORMAL, ALSO CKD DRAIN TUBES. CONFERRED WITH LM ON ALL CKS. REPLACED CAPT'S ALTIMETER MM. TESTED NORMAL.

Source: SDR UALA2010121304533
OTHER · 2010-11-21 Unresolved
ATA 2300

Part: AMPLIFIER — INOPERATIVE (SATCOMM) · airframe 80,143 hrs · 12,910 cycles

SATCOM HI GAIN INOPERATIVE. AMPLIFIER FOUND DEFECTIVE. REPLACED HIGH POWER AMPLIFIER.

Source: SDR UALA2010112204306
FLUID LOSS · 2010-11-05 Unresolved
ATA 2710

Part: ACTUATOR — LEAKING (AILERONS) · airframe 79,934 hrs · 12,880 cycles

LT WING AFT OF PYLON SAIL TAIL AREA HAS EVIDENCE OF HYD LEAK. LEAK IS AT LT INBD AILERON INBD ACTUATOR ON ACT ROD SEAL. LEAK IS MEASURED AT 4 DROPS PER MIN. COMPLETED ACTUATOR REPLACEMENT.

Source: SDR UALA2010110504104
VIBRATION/BUFFET · 2010-11-01 Unresolved
ATA 2761

Part: ACTUATOR — BYPASSING (SPOILERS) · airframe 79,884 hrs · 12,873 cycles

OPERATED HYD & TURNED CONTROL WHEEL LEFT, CAN FEEL SHUTTER, VIBRATION IN COCKPIT AIRFRAME, CONTROL WHEEL & FROM INBD AILERON TO OTBD AILERON WHILE IT STILL HELD IN LT TURN. ISOLATED TO CTR HYD SYS. NO VIB IN RT & LT HYD SYS ON. RT WING AILERON OK NO VIBS. ISOLATED VIBS TO NR3 SPOILER ACTUATOR BYPASSING.

Source: SDR UALA2010110104040
WARNING INDICATION · 2010-10-21 Unresolved
ATA 2840

Part: PRESSURE SWITCH — FAULTED (LEFT) · airframe 79,728 hrs · 12,851 cycles

LEFT FWD BOOST PUMP LOW PRESSURE LIGHT INOPERATIVE. CLEANED CONNECTOR AND BLEED PRESSURE SWITCH LINE, NO HELP. DEFERRED PUMP INOPERATIVE. REPLACED LT FWD FUEL BOOST PUMP PRESSURE SWITCH (S70) IAW MM. CHECKED GOOD, NO LEAKS.

Source: SDR UALA2010102103896
OTHER · 2010-09-02 Unresolved
ATA 3040

Part: CONTROLLER — INOPERATIVE (WINDOW HEAT) · airframe 79,125 hrs · 12,769 cycles

LT WINDOW SIDE HEAT INOPERATIVE. REPLACED M192 WINDOW HEAT CONTROLLER, WINDOW HEAT OPERATION RESTORED.

Source: SDR UALA2010090303255
FLUID LOSS · 2010-08-17 Unresolved
ATA 2910

Part: LINE — LEAKING (HYD SYSTEM) · airframe 78,996 hrs · 12,748 cycles

HYD FLUID LEAKING FROM LT PYLON INBD DRAIN.

Source: SDR UALA2010081903056
FLUID LOSS · 2010-08-16 Unresolved
ATA 2910

Part: LINE — LEAKING (HYD SYSTEM) · airframe 78,996 hrs · 12,748 cycles

HEAVY HYD LEAK NR 1 PYLON. SUPPLEMENTAL DATA UPDATE HYDRAULIC FLUID LEAKING FROM LEFT PYLON INBD DRAIN WHILE REVERSER DEPLOYED AND LEFT HYDRAULICS PRESSURIZED. LINE IS LOCATED BETWEEN RESERVOIR AND INTO A BULKHEAD, EXTREMELY TIGHT ACCESS. LINE REMOVAL IS IN PROGRESS. NON STOCK AOG T6833. FOUND LEAK FWD OF LH HYD RESERVOIR IN SAIL TAIL ON REVERSER PRESS LINE. REMOVED LINES AND ROUTED TO SFO. HAD DIFFICULTY SEPARATING LINE NR 20 FROM LINE NR 45. LINE NR 45 ALSO ROUTED TO SFO FOR MANUFACTURE. HAD DIFFICULTY SEPARATING LINE NR 20 FROM LINE NR 45. LINE NR 45 ALSO ROUTED TO SFO FOR MANUFACTURE. INSTALL NEW LINES AND PRESSURE TEST LINES, NO LEAKS FROM NEW LINES. REVERSER OPS NORMAL.

Source: SDR UALA2010081703015
OTHER · 2010-08-14 Unresolved
ATA 3610

Part: ISOLATION VALVE — DEFECTIVE (BLEED AIR SYS) · airframe 78,966 hrs · 12,744 cycles

LEFT ISOLATION VALVE WOULD NOT OPEN. REPLACED LT ISOLATION VALVE. OPS CHECK NORMAL.

Source: SDR UALA2010081602998
OTHER · 2010-08-12 Unresolved
ATA 3460

Part: CDU — FAILED (RIGHT) · airframe 78,924 hrs · 12,737 cycles

RH FMC/CDU FAILURE, FLIGHT DIVERTED. 1ST OFFICER'S CONTROL DISPLAY UNIT FOUND FAULTY. REPLACED F-O'S CDU PER AMM. RT CDU CHECKS SATIS.

Source: SDR UALA2010081202941
OTHER · 2010-06-30 Unresolved
ATA 2330

Part: ENTERTAIN SYS — INOPERATIVE (CABIN) · airframe 78,301 hrs · 12,653 cycles

ENTIRE PASSENGER ENTERTAINMENT SYSTEM IS INOPERATIVE.

Source: SDR UALA2010063002338
OTHER · 2010-05-09 Unresolved
ATA 3245

Part: TIRE — UNKNOWN (MLG) · airframe 77,565 hrs · 12,555 cycles

TIRE DEBRIS ON T/O ROLL, RTFL. REPLACED TIRE.

Source: SDR UALA2010051001582
OTHER · 2010-05-07 Unresolved
ATA 2421

Part: IDG — FAULTY (RT ENGINE) · airframe 77,542 hrs · 12,552 cycles

RT ENG GEN DRIVE LIGHT NOT ILLUMINATED AFTER ENGINE SHUTDOWN. BPCU BITE FAULTED R IDG PRESS SWITCH OR WIRING. DISCONNECTED IDG. REPLACED IDG IAW MM. SERVICED OIL, LEAK CHECKED. NO LEAKS WERE NOTED. RAN ENGINE PERFORMED IDG DISCONNECT TEST, NORMAL OPS.

Source: SDR UALA2010050701563
SMOKE/FUMES/ODORS/SPARKS · 2010-04-29 Unresolved
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 77,433 hrs · 12,537 cycles

CREW REPORTS IN CLIMBOUT COULD SMELL ELECTRICAL TYPE ODOR. STRONGEST FROM ROWS 6-20. ENTERTAINMENT SYS AND BUFFER BOXES TURNED OFF. ODOR DISSIPATED WHEN CRUISE WAS REACHED. INBD FLT ATT SUSPECTED SMELL COMING FROM ONE OF THE MONITORS IN BUS CLASS. RAN IFE FOR APPROX 1HR, INSPECTED CABIN AND GALLEYS. NO SMELL NOTED. RAN PACKS, RECIRC FANS ARE RUNNING, NO ELECTRICAL SMELLS NOTED. ETOPS VERIFICATION OK, CF ITEM CLEARED. NFF.

Source: SDR UALA2010043001448
WARNING INDICATION · 2010-04-09 Unresolved
ATA 5242

Part: PIN — OUT OF ADJUST (E/E DOOR LATCH) · airframe 77,218 hrs · 12,503 cycles

E&E DOOR EICAS MESSAGE, RTFL. FOUND FLAT SPOT OF LATCH PIN OUT OF ADJUSTMENT MORE THAN 4 DEGREES AND TARGET TOO CLOSE. REMOVED SHIMS AND ADJUSTED PIN. ADJUSTED E&E DOOR. ACCOMPLISHED CHECK OF E-E DOOR. CLEANED AND LUBED MECHANISMS AND JAR CHECKED. UNABLE TO DUPLICATE ON GROUND. NO FAULTS PSEU DUE ONLY EICAS MESSAGE. SUSPECT PSEU CARD M162. DOOR OPS CHECKED OK AT ORD .

Source: SDR UALA2010041201232
NO TEST · 2010-04-09 Unresolved
ATA 3397

Part: CONNECTOR — UNSECURE (CABIN) · airframe 77,217 hrs · 12,502 cycles

EMERGENCY LIGHT AT SEAT 2A INOP. SECURED CONNECTOR, OPS CHECK OK.

Source: SDR UALA2010040901188
WARNING INDICATION · 2010-01-20 Unresolved
ATA 2612

Part: CIRCUIT BREAKER — TRIPPED (FIRE SUPPRESSION) · airframe 76,261 hrs · 12,364 cycles

APU INOP ACCT FIRE DISCHARGE LIGHT ILLUMINATED. THIS CONDITION INDICATES A BAD PRESSURE SWITCH AND THE APU FIRE EXTINGUISHER BOTTLE SHOULD BE REPLACED. REPLACED BOTTLE ASSY, NO HELP. CREW REPORTS CB C796 APU REMOTE FIRE INDICATOR CIRCUIT BREAKER POPPED. PULLED & COLLARED. VERIFIED NO OTHER A-C SYS AFFECTED.

Source: SDR UALA2010012100261
SMOKE/FUMES/ODORS/SPARKS · 2010-01-05 Unresolved
ATA 2550

Part: PDU — FAULTY (AFT CARGO BAY) · airframe 76,068 hrs · 12,338 cycles

AFT CARGO PIT, AFT CARGO LOADING SYS CHECK. DURING CHECK SMOKE WAS COMING OUT FROM UNDER CARGO PIT FLOOR PANELS ON LT SIDE FWD OF CARGO DOOR. 2 EACH PDU CONTROL C-B. REPLACED PDUS AT 3L AND 7L, OPS CHECKED GOOD.

Source: SDR UALA2010010700078

2009

OTHER · 2009-11-22 Unresolved
ATA 3610

Part: CONTROLLER — MALFUNCTIONED (BLEED AIR SYS) · airframe 75,484 hrs · 12,251 cycles

RIGHT BLEED LOSES PRESS WHENEVER THROTTLE IS IN LOW THRUST CONDITION. REPLACED PRESSURE REGULATING VALVE CONTROLLER. RAN ENG PNEU PRESSURE NORMAL.

Source: SDR UALA2009112303647
WARNING INDICATION · 2009-11-22 Unresolved
ATA 2997

Part: WIRE — SHORTED (HYDRAULIC SYS) · airframe 75,482 hrs · 12,250 cycles

LEFT SYSTEM AND LEFT DEMAND PUMP LOW PRESSURE LIGHT ILLUMINATED WITH PUMP ON AND EICAS SHOWING 3000 PSI. ISOLATED M925 TIME DELAY MODULE AND CHECK RESISTANCE FROM M925 TO LOW PRESS CONNECTOR. METER SHOWED 1.6 OR WIRE GROUNDED. ISOLATED GROUND IN WIRE BUNDLE FROM D4280P TO D52 REF WIRE DIAGRAM 29-11-12. ACCOMPLISHED WIRE CHECK FROM D52 TO APPROX 3 FEET. NO DEFECT FOUND. MOVED WIRE NEAR CON D4280P AND SHORT WENT AWAY. FOUND SHORTED WIRE PIN 4 ON WIRE W398-006-18 ABOUT 8 INCHES AFT OF D4280P. ACCOMPLISHED REPAIR. PERFORMED OPERATION. CHECK OF LT HYD PUMP IN AUTO AND ON, PRESSURES NORMAL AND NO FAULT LIGHT NOTED.

Source: SDR UALA2009112303648
NO TEST · 2009-11-20 Unresolved
ATA 3350

Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 75,477 hrs · 12,248 cycles

OVERWING EMERGENCY EXIT SIGN L297, L322, L699 AND L700 INOP. REPLACED M1209 EMERGENCY LIGHTS PWR SUPPLY. TEST OKAY.

Source: SDR UALA2009112303631
OTHER · 2009-09-28 Unresolved
ATA 5610

Part: WINDOW — LEAKING (COCKPIT) · airframe 74,872 hrs · 12,160 cycles

LOUD PRESSURE LEAK AT CAPTAIN'S LEFT SLIDING WINDOW. SUSPECTED LEAK AREA MARKED WITH TAPE. SQUEAL STARTED AT VERY LOW CBN DIFF PRESSURE AND CONTINUED UP TO CRZ DIFF PRESSURE OF 8.6. PRESSING ANYWHERE ON THE WINDOW DID NOT MAKE ANY DIFFERENCE. REPLACED & ADJUSTED WINDOW.

Source: SDR UALA2009092903070
OTHER · 2009-08-12 Unresolved
ATA 5754

Part: PANEL — DAMAGED (NR 5 SLAT) · airframe 74,272 hrs · 12,071 cycles

LEFT WING NR 5 LEADING EDGE SLAT HAS 2 SLAT CLOSURE PANELS WITH DAMAGE, 2ND FROM INBOARD PANEL HAS A 4 INCH CRACK THAT RUNS FROM THE AFT EDGE OF THE PANEL THROUGH 4 RIVET HOLES AND TERMINATES IN THE AFT HOLE, 3RD FROM INBOARD PANEL HAS SOME DELAM IN THE OUTBOARD CORNER MEASURING 0.5 BY 0.75 INCHES. ALSO A SMALL NICK OUT OF THE INBOARD CORNER. ACCOMPLISHED CHECKS AND REPAIRS PER EVA 72876. DELAMINATED PLY STOP DRILLED. BOTH PANELS CHECKED FOR FURTHER DELAMINATION AND MOUNTING BRACKETS CHECKED FOR CRACKS OR DAMAGE. NO FURTHER DAMAGE. TAPED PANELS WITH SPEED TAPE AND OPERATED FLAPS AND OPERATION NORMAL. THIS INTERIM REPAIR FOR 50 FLT HRS (MAX PTT 74322) WITH REQUIRED RE-INSPECTION OF THE ALUMINIUM SPEED TAPE FOR DETERIORATION AND A DETAILED VISUAL INSPECTION OF THE AREA EVERY FLT. RE-APPLY SPEED TAPE AS REQUIRED.

Source: SDR UALA2009081302474
SMOKE/FUMES/ODORS/SPARKS · 2009-07-28 Unresolved
ATA 2120

Part: COFFEEMAKER — CONTAMINATED (FWD GALLEY) · airframe 74,095 hrs · 12,043 cycles

STRONG ELECTRICAL ODOR EMANATING FROM SEAT 2A. CHECKED ALL AREAS AROUND SEAT 2A AND 1A. ALSO FWD CARGO PIT AREA. FOUND ALL TO BE GOOD. ALSO INOP SEAT 2A ELECTRICAL. RETURNED TO BLOCK A 2ND TIME FOR ELEC ODOR AT SEAT 2A. INSPECTED SEAT, FOUND NO ABNORMALITIES, CYCLED SEAT NUMEROUS TIMES, RAN ENGINES AND PACKS FOR 20 MINUTES, PERFORMED EMERGENCY LIGHT TEST AND FOUND NO ABNORMAL ELEC ODOR IN CABIN OR THE E&E COMPARTMENT. FELT SIDEWALL PANELS AND SEAT AREA FOR HOT SPOTS, NONE FOUND. MECH FOUND PLASTIC ON COFFEEMAKER IN FWD GALLEY AND REPLACED.

Source: SDR UALA2009072902277
OTHER · 2009-06-20 Unresolved
ATA 2131

Part: CONTROLLER — FAILED (CABIN PRESSURE) · airframe 73,585 hrs · 11,965 cycles

CABIN CLIMB EXCESS 2000FPM WITH BOTH PACKS OFF. REPLACED CABIN PRESSURE CONTROLLER. OPS CHECKS GOOD. PERFORMED CABIN LEAK CHECK, LEAK CHECKS GOOD.

Source: SDR UALA2009062301771
WARNING INDICATION · 2009-04-14 Unresolved
ATA 3460

Part: FMC — DEFECTIVE (RIGHT) · airframe 72,868 hrs · 11,857 cycles

RIGHT FMC FAILED. RTFL. CYCLED C/B FOR RIGHT FMC, MESSAGE CLEARED AND OPS CHECKS GOOD. RT FMC NEEDS PRECAUTIONARY REPLACEMENT DUE TO FMC FAILURE IN FLIGHT. REPLACED RT FMC. CLOSED BOTH BREAKERS FMC WILL NOT SYNC GIVES MESSAGE RESYNC FAILED SINGLE FMC WITH RT FMC FAILED EICAS. WITH JUST RT BREAKER IN RT OPERATES WITH CORRECT OPS SOFTWARE PN DISPLAYED. NAV DATA DRAG FACTOR AND FF FACTOR INCORRECT. REPLACED FMC. CORRECT OP SOFTWARE INSTALLED PS4052970-959. FMC CHECKS OK, NO FAULT LIGHTS.

Source: SDR UALA2009041401071
OTHER · 2009-03-02 Unresolved
ATA 3350

Part: LENS — BROKEN (EXTERIOR) · airframe 72,379 hrs · 11,784 cycles

FUSELAGE EXTERIOR EMERGENCY LIGHT LENS BROKEN RT SIDE APPROX 24 INCHES FWD OF AFT PIT DOOR. REMOVED AND REPLACED EMERGENCY LIGHT LENS.

Source: SDR UALA2009031000698
OTHER · 2009-03-02 Unresolved
ATA 3350

Part: LENS — BROKEN (EXTERIOR) · airframe 72,379 hrs · 11,784 cycles

FUSELAGE EXTERIOR EMERGENCY LIGHT LENS BROKEN RT SIDE APPROX 24 INCHES FWD OF AFT PIT DOOR. REMOVED AND REPLACED EMERGENCY LIGHT LENS.

Source: SDR UALA2009030300698
OTHER · 2009-01-25 Unresolved
ATA 2565

Part: SLIDE — LOW PRESSURE (L2 DOOR) · airframe 72,210 hrs · 11,756 cycles

DOOR 2L SLIDE PRESSURE BELOW SERVICEABLE LIMIT. REPLACED 2L SLIDE.

Source: SDR UALA2009012600274

2008

WARNING INDICATION · 2008-12-16 Unresolved
ATA 2710

Part: ACTUATOR — FAULTY (AILERONS) · airframe 71,682 hrs · 11,677 cycles

THE "AIL LOCK" LT ON AT LOW SPEED. EICAS MSG AILERON LOCKOUT DISPLAYED. REPLACED RIGHT WING AILERON LOCKOUT ACTUATOR. REPLACED RT WING AILERON LOCKOUT ACTUATOR. TESTED NORMAL. RECEIVED SAME EICAS SEVERAL FLIGHT SEGMENTS LATER. REPLACED RIGHT SAM AND RT ADC (P/N S242T210-211). MCDP TEST 30 AND 65 CHECKS OK.

Source: SDR UALA2008121706912
WARNING INDICATION · 2008-09-30 Unresolved
ATA 7261

Part: OIL FILTER — DEFECTIVE (RT ENGINE) · airframe 70,638 hrs · 11,535 cycles

THE 'R OIL FILTER' STATUS MSG DISPLAYED. REPLACED MAIN OIL FILTER & ENGINE OIL SCREEN. ENG RUN PERFORMED. NO LEAKS NOTED AND NO FURTHER MSG DISPLAYED.

Source: SDR UALA2008111305934
WARNING INDICATION · 2008-09-30 Unresolved
ATA 7930

Part: WARNING SYSTEM — ACTIVATED (COCKPIT) · airframe 70,638 hrs · 11,535 cycles

THE 'R OIL FILTER' STATUS MSG DISPLAYED.

Source: SDR 2008UALA05934
INADEQUATE Q C · 2008-09-27 Unresolved
ATA 2820

Part: ACTUATOR — MALFUNCTIONED (FUEL SYSTEM) · airframe 70,598 hrs · 11,530 cycles

FUEL SHUTOFF VALVE PROBLEM. RTBL. REPLACED SPAR VALVE ACTUATOR. OP CHECKS GOOD.

Source: SDR 2008UALA05900
OTHER · 2008-09-03 Unresolved
ATA 2400

Part: CONTROL UNIT — FAILED · airframe 70,276 hrs · 11,485 cycles

EICAS MSG (L,R) UTIL BUSS OFF DISPLAYED. UTILITY BUSS OFF LGT ILLUM. SYS FAILED TO RESET. BUSS PCU FAILURE. REPLACED BUSS POWER CONTROL UNIT.TESTS OKAY. RAN BOTH ENGINES & RAN ALL ELECTRICAL POWER SYSTEMS USING ALT BUSSES ALL INDICATION & OPS NORMAL.

Source: SDR 2008UALA05576
WARNING INDICATION · 2008-08-14 Unresolved
ATA 7261

Part: FILTER — UNKNOWN (ENGINE OIL) · airframe 70,016 hrs · 11,447 cycles

LT ENGINE OIL FILTER STATUS MESSAGE. *S/D* REPLACED MAIN OIL FILTER.

Source: SDR 2008UALA04274
FLUID LOSS; WARNING INDICATION · 2008-07-05 Unresolved
ATA 2910

Part: HYDRAULIC SYSTEM — LEAKING · airframe 69,481 hrs · 11,362 cycles

HYDRAULIC FLUID LOSS. FLIGHT DIVERTED.

Source: SDR 2008UALA03706
INADEQUATE Q C · 2008-06-29 Unresolved
ATA 7931

Part: LIGHT — INOPERATIVE (COCKPIT) · airframe 69,430 hrs · 11,355 cycles

THE L ENG OIL PRESS LIGHT IS NOT ILLUMINATED ON FORWARD 1ST PANEL.

Source: SDR 2008UALA03623
WARNING INDICATION · 2008-06-18 Unresolved
ATA 2421

Part: IDG — FAULTY (NR 1) · airframe 69,257 hrs · 11,332 cycles

L GEN DRIVE LIGHT CONTINUOUSLY FLICKERS IN FLIGHT. GEN WORKS NORMALLY. *S/D* SUSPECT FAULTY INTEGRATED DRIVE GENERATOR. REPLACED LEFT IDG PER MM 24-11-01, ALL OPS AND INDICATE NORMAL. AC OK FOR SERVICE.

Source: SDR 2008UALA03451
WARNING INDICATION · 2008-06-14 Unresolved
ATA 2100

Part: SHUTOFF VALVE — FAULTY (COOLING FAN) · airframe 69,196 hrs · 11,324 cycles

EQUIPMENT COOLING FAN EICAS MESSAGE. AFTER TROUBLESHOOTING FOUND SHUTOFF VALVE TO BE FAULTY. REPLACED VALVE PER MM 21-23-08, ALL OPS & INDICATIONS NOW NORMAL. AC OK FOR SERVICE.

Source: SDR 2008UALA03368
OTHER · 2008-06-05 Unresolved
ATA 5330

Part: SKIN — GOUGED (FUSELAGE) · airframe 69,120 hrs · 11,309 cycles

DEEP GOUGE ON FUSE SKIN AT STA 256.25 TO 276 AND STR 31R, JUST AFT OF CREW O2 DISCHARGE. MAJOR REPAIR ACCOMPLISHED: REMOV'D DAMAGED SKIN, INSTALLED DOUBLER REPAIR.

Source: SDR 2008UALA03228
OTHER · 2008-04-19 Unresolved
ATA 2721

Part: TRIM SYSTEM — INOPERATIVE (RUDDER) · airframe 68,952 hrs · 11,273 cycles

LEFT RUDDER TRIM INOP.

Source: SDR 2008UALA02329
WARNING INDICATION · 2008-04-12 Unresolved
ATA 2121

Part: FAN — FAULTY · airframe 68,859 hrs · 11,259 cycles

"FWD DET FAN" MAINTENANCE MESSAGE, WILL NOT CLEAR. SUSPECT FAULTY FAN AND OR PRESSURE SWITCH. REPLACED FAN AND PRESSURE SWITCH OPS CHECK GOOD MESSAGE CLEARED. AC OK FOR SERVICE.

Source: SDR 2008UALA02138
INADEQUATE Q C · 2008-03-10 Unresolved
ATA 2560

Part: MASK — CRACKED (COCKPIT) · airframe 68,450 hrs · 11,195 cycles

SMOKE MASK ON CAPTAIN'S SIDE IS CRACKED.

Source: SDR 2008UALA01326
F.O.D.; SMOKE/FUMES/ODORS/SPARKS · 2008-03-09 Unresolved
ATA 2150

Part: CONTROL VALVE — FOD (A/C PACK) · airframe 68,441 hrs · 11,194 cycles

LEFT PACK FAILED ON TAKEOFF WITH PACK INOP AND PACK OFF DISPLAYED RESET NORMAL BUT HAD PLASTIC BURNING SMELL AND ALSO A RATTLING SOUND IN DUCTING AREA ABOVE SEAT 9C. CREW SELECTED PACK OFF AGAIN AND BURNING SMELL AND RATTLE STOPPED. FOUND LEFT PACK CONTROL VALVE NOT OPENING FULLY FOUND PLASTIC IN BUSINESS CLASS WARMING OVEN, REMOVED PLASTIC. REPLACED VALVE PER MM 21-51-01. PACK OPS CHECKS NORMAL. AC OK FOR SERVICE.

Source: SDR 2008UALA01295
OTHER · 2008-03-09 Unresolved
ATA 3350

Part: LIGHT — LOOSE (CABIN) · airframe 68,436 hrs · 11,193 cycles

EMERGENCY EXIT PATH LIGHTING IN FIRST CLASS IS LOOSE. SECURED LIGHT OPS CHECKED GOOD. AC OK FOR SERVICE.

Source: SDR 2008UALA01325
INADEQUATE Q C · 2008-01-21 Unresolved
ATA 3350

Part: CAP — MISSING (CABIN) · airframe 67,813 hrs · 11,104 cycles

EEL END CAP MISSING, BY 1E. REPLACED END CAP. OPS CHECKS GOOD.

Source: SDR 2008UALA00363
NO TEST · 2008-01-05 Unresolved
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 67,639 hrs · 11,077 cycles

THE M736 BATTERY FOR LEFT EXTERIOR EMERGENCY LIGHTS IS INOP. REPLACED BATTERY (M736), OPS CHECKS GOOD.

Source: SDR 2008UALA00121
OTHER · 2008-01-05 Unresolved
ATA 5320

Part: SILL — CORRODED (BS 566-569) · airframe 67,639 hrs · 11,077 cycles

FWD PIT FLOOR LWR DOOR SILL CORRODED STA 566 TO 569 RBL 42 TO RBL 43. SUSPECT MOISTURE CONTAMINATION. CORRODED SILL. FWD CARGO DOOR LOWER SILL, STA 566-569, BL42R TO BL43R REPAIRED ON WU 35948 DURING C12 VISIT. UA-EVA-71016A. ACFT OK FOR SERVICE.

Source: SDR 2008UALA00084
OTHER · 2008-01-05 Unresolved
ATA 5311

Part: FITTING — CRACKED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles

AFT CARGO BAY, STA 1285, RBL 42, AFT SIDE OF FRAME UPPER FITTING IS CRACKED. REPLACED FITTING REF SRM 51-40-02. FAB FITTING REF BAC DWG 146T8068 AND REO-G1221 REV-A BY MECH, AND INSP QC.

Source: SDR 2008UALA00083
INADEQUATE Q C · 2008-01-03 Unresolved
ATA 3397

Part: WIRE — BROKEN (L1 DOOR) · airframe 67,639 hrs · 11,077 cycles

L1 DOOR LWR EMERGENCY EXIT IDENTIFIER SIGN L979 WIRES ARE BROKEN.

Source: SDR 2008UALA00066
NO TEST · 2008-01-02 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 67,639 hrs · 11,077 cycles

AFT LEFT AND RIGHT LAV EEL LIGHT BARS ARE INOP.

Source: SDR 2008UALA0044

2007

NO TEST · 2007-12-31 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 67,639 hrs · 11,077 cycles

FS-3 LAV EMERGENCY LIGHT PATH BAR INOP AT LAV DOOR.

Source: SDR 2008UALA0021
OTHER · 2007-12-26 Unresolved
ATA 5720

Part: WEB — CRACKED (LT WING) · airframe 67,639 hrs · 11,077 cycles

LEFT WING FIXED LEADING EDGE FORWARD WEB CRACK LOWER AREA AT STA 654. MAJOR REPAIR ACCOMPLISHED: STOP DRILLED CRACK. FABRICATED & INSTALLED DOUBLER REPAIR.

Source: SDR 2007UALA05305
INADEQUATE Q C · 2007-12-22 Unresolved
ATA 3500

Part: CASE — CRACKED (O2 SYSTEM) · airframe 67,639 hrs · 11,077 cycles

SUPPLEMENTAL - O2 CASE CRACKED.

Source: SDR 2007UALA05271
OTHER · 2007-12-21 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles

AFT CARGO BAY, STA 1131, RBL 36, TEE CAP CORRODED UNDER NUT PLATES.

Source: SDR 2007UALA05219
OTHER · 2007-12-21 Unresolved
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles

MAIN CABIN GALLEY FLOOR SUPPORT CORRODED AT STA 790 TO 800 BL 9R TO 10R.

Source: SDR 2007UALA05217
INADEQUATE Q C · 2007-12-21 Unresolved
ATA 2565

Part: HOSE — COLLAPSED (EVAC SLIDE) · airframe 67,639 hrs · 11,077 cycles

RIGHT OVERWING SLIDE INFLATION HOSE COLLAPSED.

Source: SDR 2007UALA05247
OTHER · 2007-12-21 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles

AFT PIT "T" CAP CORRODED STA 1197, LBL 34 TO LBL 41.

Source: SDR 2007UALA05218
OTHER · 2007-12-19 Unresolved
ATA 5315

Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles

FLOORBEAM CRACKED IN UPPER CHORD BS 325 LBL 10 AND ADJACENT FASTENER SHEARED.

Source: SDR 2007UALA05171
OTHER · 2007-12-19 Unresolved
ATA 5320

Part: STIFFENER — CRACKED (NLG WW) · airframe 67,639 hrs · 11,077 cycles

LEFT VERTICAL STIFFENER IN NOSE WHEEL WELL, BS 287, HAS ONE HALF INCH CRACK IN THE RADIUS. CRACK BEGINS 11.375 INCHES FROM NWW UPPER CEILING WEB.

Source: SDR 2007UALA05172
OTHER · 2007-12-19 Unresolved
ATA 2560

Part: SPRING — WEAK (PAX DOOR) · airframe 67,639 hrs · 11,077 cycles

LEFT FWD MAIN ENTRY DOOR DEPLOYMENT BAR GAS SPRING IS WEAK.

Source: SDR 2007UALA05186
OTHER · 2007-12-19 Unresolved
ATA 2565

Part: SLIDE — FAULTY (CABIN) · airframe 67,639 hrs · 11,077 cycles

RIGHT OVERWING SLIDE AFT AREA, ARM CAM OF SLIDE HITTING STOP BLOCK FITTING.

Source: SDR 2007UALA05185
OTHER · 2007-12-19 Unresolved
ATA 2565

Part: CYLINDER — DEFECTIVE (EVAC SLIDE) · airframe 67,639 hrs · 11,077 cycles

RIGHT OVERWING ESCAPE SLIDE CYLINDER DEPLOYMENT CABLE BALL IS BELOW SPRING FORCE RETAINER.

Source: SDR 2007UALA05183
OTHER · 2007-12-19 Unresolved
ATA 2565

Part: SLIDE — FAULTY (CABIN) · airframe 67,639 hrs · 11,077 cycles

LEFT OVERWING SLIDE AFT AREA, ARM CAM OF SLIDE HITTING STOP BLOCK FITTING.

Source: SDR 2007UALA05184
OTHER · 2007-08-24 Unresolved
ATA 3510

Part: OXYGEN MASK — LEAKING (COCKPIT) · airframe 66,250 hrs · 10,857 cycles

CAPTAIN'S OXYGEN MASK HEAD STRAPS LEAKS AIR WHEN INFLATED. REPLACED MASK PER MM 35-11 -51.CKS GOOD.

Source: SDR 2007UALA03412
NO TEST · 2007-08-21 Unresolved
ATA 3350

Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 66,221 hrs · 10,852 cycles

EMERGENCY EEL LIGHT INOP FROM SEAT 31HJ TO 39 HJ. REPLACED BATTERY POWER SUPPLY.

Source: SDR 2007UALA03315
NO TEST · 2007-07-15 Unresolved
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 65,738 hrs · 10,766 cycles

EXTERNAL EEL LIGHT JUST AFT OF LEFT WING IS INOP. [07-27-07] RELAMPED AND LIGHT CHECKS GOOD.

Source: SDR 2007UALA02651
OTHER · 2007-04-20 Unresolved
ATA 7200

Part: ENGINE — SURGES (NR 2) · airframe 64,693 hrs · 10,593 cycles

NR 2 ENG SURGED DURING GROUND RUN FOR BLEED T-S. [SUP 05-18-07] ACCOMPLISHED NR 2 ENGINE VISUAL CHK. REPLACED IDG OIL AND SCAV. OIL FILTER. INSPECTED MAG CHIP DET. PER MM79-21-1 0 601. NR 2 ENGINE REQUIRES BORESCOPE PER TROUBLESHOOTING OF SMC2. BORESCOPED C5,C6,C14,C15, T1&T2 AS REQ IN MM 71-05-00. FOUND ALL OK FOR INTERVAL-1. A/C RETURNED TO SERVICE.

Source: SDR 2007UALA01285
NO TEST · 2007-03-14 Unresolved
ATA 3397

Part: FEEDER CABLE — DAMAGED (EMERGENCY LIGHTS) · airframe 64,262 hrs · 10,515 cycles

EMERGENCY EEL LIGHTS INOP FROM SEATS 30HJ TO AFT GALLEY. SUPPLEMENTAL DATA UPDATE REPAIRED EEL STRIPS FEEDING LEFT REAR OF AIRCRAFT. OP CHECKS OK.

Source: SDR 2007UALA00771

2006

OTHER · 2006-11-20 Unresolved
ATA 3397

Part: CONNECTOR — DISCONNECTED (EMERGENCY LIGHT) · airframe 62,857 hrs · 10,263 cycles

EMERGENCY EEL LIGHT STRIP INOP AT RT MID LAV.

Source: SDR 2006UALA02234
FLAME/FIRE · 2006-07-15 Unresolved
ATA 3240

Part: BRAKE — FIRE (MLG) · airframe 61,348 hrs · 10,017 cycles

NR 4 MAIN TIRE-BRAKE FIRE AFTER A/C PARKED WITH BRAKES RELEASED. THE PROBLEM WAS CAUSED BY THE BUILD UP OF GREASE ON THE WHEEL AXLE DURING SERVICING, DURING WHILE/ TIRE CHANGE OR BRAKE INSTALLATION. FIRE WENT OUT WITHOUT NEEDING FIRE EXTINGUISHER. REPLACED 4R BRAKE AND TIRE. INSPECTED GEAR FOR HEAT DAMAGED. FOUND NONE. AMM 32-45-01/401 WHEEL AND TIRE INSTALLATION, ADVISES TECHNICIANS TO FOLLOW THE FOLLOWING PROCEDURES TO PREVENT CONTAMINATION OF THE WHEEL/TIRE ASSEMBLY; REMOVE CONTAMINATION AND UNWANTED MATERIAL FROM THE INSTALLATION COMPONENT OF THE LANDING GEAR. APPLY THIN LAYER OF WHEEL BEARING GREASE TO THE AXLE WHERE IT WILL CONTACT THE INNER AND OUTER SURFACES OF THE WHEEL BEARINGS.

Source: SDR 2006UALA01438
NO TEST · 2006-06-26 Unresolved
ATA 2162

Part: INDICATOR — MALFUNCTIONED (COCKPIT) · airframe 61,113 hrs · 9,982 cycles

EQUIP COOLING MONITOR EHSI-L, VOR-L AND FMCDU-L BALL INDICATORS DONT GO UP IN TEST. CONFIRMED RESPECTIVE SENSI NG LINES STATIC PRESSURE ABOVE 0.80 INCHES OF WATER AS PER MEL. ONLY VOR-L FAILING. CK'D AIRFLOW TO VOR-L,FOUND NORMAL. SECURED LOOSE HOSES AT MONITOR STILL NO HELP. REPLACED MONITOR. OP CHEKD OK FOR SERVICE.

Source: SDR 2006UALA01254
WARNING INDICATION · 2006-05-31 Unresolved
ATA 2710

Part: WARNING SYSTEM — ACTIVATED (COCKPIT) · airframe 60,753 hrs · 9,924 cycles

AILERON LOCKOUT EICAS DURING DESCENT FL110 250 KIAS. CLEANED AND SECURED CANON PLUG ON RIGHT ACTUATOR. OPS OK NOW.

Source: SDR 2006UALA01089

2005

OTHER · 2005-02-13 Unresolved
ATA 5315

Part: STIFFENER — CRACKED (FLOORBEAM) · airframe 55,296 hrs · 9,048 cycles

FLOORBEAM AT STA 246 HAS A CRACKED VERTICAL STIFFENER ON FWD FACE OF BEAM AT APPROX LBL 26. REPLACED CRACKED STIFFENER.

Source: SDR 2005UALA00157
OTHER · 2005-02-13 Unresolved
ATA 5712

Part: RIB — CRACKED (RT WING) · airframe 55,296 hrs · 9,048 cycles

RT WING L-E CAVITY AT FSS 512, UPPER RIB LOWER CHORD PREVIOUS REPAIR CRACKED AT AFT END-OUTBD OF NR 8 SLAT OUTBD ACTUATOR. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. RIB REPAIRED WITH ANGLE DOUBLER.

Source: SDR 2005UALA00155
OTHER · 2005-02-13 Unresolved
ATA 5315

Part: STIFFENER — CRACKED (FLOORBEAM) · airframe 55,296 hrs · 9,048 cycles

FLOORBEAM AT STA 246 HAS A CRACKED VERTICAL STIFFENER ON FWD FACE OF FLOORBEAM AT APPROX RBL 26.39. CRACKED STIFFENER WAS REPLACED.

Source: SDR 2005UALA00156

2003

PARTIAL RPM/PWR LOSS · 2003-11-01 Unresolved
ATA 7230

Part: COMPRESSOR — LEAKING (NR 1 ENGINE) · airframe 49,841 hrs · 8,135 cycles

NR 1 ENGINE SURGE ON TAKEOFF. ENGINE SELF RECOVERED AND CONTINUED NORMAL OPERATION. ENGINE EXPERIENCED GROUP 3 SURGE ON TAKE OFF. CAUSE OF THE SURGE IS OPEN CLEARANCES IN THE REAR OF THE HPC. FINAL FIX FOR SURGE ISSUES IS THE OVERHAUL OF THE ENGINE TO A RING CASE CONFIGURATION.

Source: SDR 2003UALA00831

2002

FALSE WARNING · 2002-10-01 Unresolved
ATA 2781

Part: CIRCUIT CARD — FAULTY (NR 10) · airframe 45,265 hrs · 7,356 cycles

EICAS "LE SLAT ASSY" AND ASSOCIATED LIGHT ILLUMINATED WITH INDICATED 1 DEGREE FOR BOTH LEFT AND RIGHT. TROUBLESHOT SYSTEM PER FAULT ISOLATION MANUAL. FOUND A5 DRIVER CARD IN THE NR 10 POSITION IN THE PROXIMITY SWITCH ELECTRONIC UNIT FAULTED. REPLACED CARD SYSTEM OP CHECKS OK.

Source: SDR 2002UALA01529
FLUID LOSS; WARNING INDICATION · 2002-09-11 Unresolved
ATA 1430

Part: SCREW — BACKED OUT (LT ENGINE) · airframe 45,095 hrs · 7,323 cycles

NO OIL PRESSURE IN LEFT ENGINE, ENGINE SHUTDOWN. FLIGHT LANDED WITHOUT INCIDENT. OIL PUMP DRIVE GEAR FAILURE. REF IPC 72-61-00-019: OIL PUMP DRIVE BEARING AND GEAR ASSY WERE FOUND LOOSE AND COCKED IN THE GEARBOX BEARING BORE. BEARING RETAINING SCREWS WERE BACKED OUT OF THE GEARBOX HOUSING AND LAYING IN THE BOTTOM OF THE GEARBOX. THIS RESULTED IN FRACTURE OF THE OIL PUMP DRIVE MODULE GEAR SHAFT IN THE WEB OF THE GEAR. ENGINE WILL REQUIRE OVERHAUL OF ALL BEARINGS DUE TO LOSS OF OIL PRESSURE.MAIN GEARBOX WILL BE OVERHAULED.

Source: SDR 2002UALA01444
NO TEST · 2002-05-14 Unresolved
ATA 3397

Part: WIRE HARNESS — FAULTY (CABIN) · airframe 43,739 hrs · 7,061 cycles

SECTION OF FLOOR EMERGENCY EXIT LIGHT BEGINNING AT RIGHT SIDE CLOSET AT MID GALLEY AND ENDING AT AFT EDGE OF MID LAV FORWARD OF ROW 15 IS INOPERATIVE. REPAIRED CABLE EMERGENCY ESCAPE PATH LIGHTING.

Source: SDR 2002UALA00878
OTHER · 2002-03-29 Unresolved
ATA 5312

Part: BULKHEAD — PUNCTURED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 246 RBL 50 BULKHEAD WEB IS PUNCTURED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER.

Source: SDR 2002UALA00604
OTHER · 2002-03-29 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 832 RBL II TRANSBEAM UPPER CAP IS CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED SPLICES.

Source: SDR 2002UALA00603
OTHER · 2002-03-23 Unresolved
ATA 5330

Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

CHAFED LOWER SKIN AFT OF STATION 1725.5 ABOVE STRINGER 22 LT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER.

Source: SDR 2002UALA00548
OTHER · 2002-03-23 Unresolved
ATA 5315

Part: CLIP — BROKEN · airframe 43,180 hrs · 6,953 cycles

FLOOBEAM ATTACH CLIP BROKEN STATION 390LH, FORWARD PIT ABOVE STRINGER 33L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW CLIP.

Source: SDR 2002UALA00544
OTHER · 2002-03-23 Unresolved
ATA 5315

Part: SPLICE — GOUGED · airframe 43,180 hrs · 6,953 cycles

STATION 880, RBL 54, TRANSBEAM OUTBOARD SPLICE GOUGED BEYOND LIMITS. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICE.

Source: SDR 2002UALA00546
OTHER · 2002-03-23 Unresolved
ATA 5315

Part: SPLICE — GOUGED · airframe 43,180 hrs · 6,953 cycles

STATION 880, RBL 33, TRANSBEAM INBOARD SPLICE IS GUOGED BEYOND LIMITS. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED SPLICE.

Source: SDR 2002UALA00547
OTHER · 2002-03-23 Unresolved
ATA 5210

Part: DOOR FRAME — CORRODED (L2 DOOR) · airframe 43,180 hrs · 6,953 cycles

L-2 DOOR CHORD HAS SEVERE CORROSION-EXFOLIATION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FILLER AND DOUBLER.

Source: SDR 2002UALA00545
OTHER · 2002-03-23 Unresolved
ATA 5315

Part: CAP — CORRODED · airframe 43,180 hrs · 6,953 cycles

CABIN STAION 832-RBL 11, TRANSBEAM UPPER CAP IS CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED WITH SPLICE BEAM.

Source: SDR 2002UALA00542
OTHER · 2002-03-23 Unresolved
ATA 5330

Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

FUSE SKIN CHAFED, FORWARD SKIN, STATION 1725.5 AT STRINGER 22 RT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR DOUBLER.

Source: SDR 2002UALA00551
OTHER · 2002-03-23 Unresolved
ATA 5330

Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

CHAFED LOWER SKIN AFT OF STATION 1725.5 ABOVE STRINGER 22 RT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR DOUBLER.

Source: SDR 2002UALA00549
OTHER · 2002-03-23 Unresolved
ATA 5315

Part: CLIP — BROKEN · airframe 43,180 hrs · 6,953 cycles

FLOOR BEAM ATTACH CLIP BROKEN STATION 434 LFT HAND, FORWARD PIT ABOVE STRINGER 33L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED CLIP.

Source: SDR 2002UALA00543
OTHER · 2002-03-23 Unresolved
ATA 5330

Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

LEFT HAND FUSELAGE SKIN CHAFED AFT OF STATION 1809.5 AT STRINGER 17. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR DOUBLER.

Source: SDR 2002UALA00550
OTHER · 2002-03-23 Unresolved
ATA 5312

Part: BULKHEAD — PUNCTURED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

CABIN STATION 246, RBL 50, BULKHEAD WEB IS PUNCTURED. MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED DOUBLER.

Source: SDR 2002UALA00540
OTHER · 2002-03-23 Unresolved
ATA 5315

Part: CAP — CORRODED · airframe 43,180 hrs · 6,953 cycles

CABIN STATION 832, RBL 11, TRANSBEAM UPPER CAP IS CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED SPLICE.

Source: SDR 2002UALA00541
OTHER · 2002-03-20 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 800-852 LBL 54.81 TRANSVERSE BEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICES.

Source: SDR 2002UALA00518
OTHER · 2002-03-20 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 852 RBL 54-81 TRANSVERSE BEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICES.

Source: SDR 2002UALA00517
OTHER · 2002-03-17 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

CABIN STATION 850, LBL 33, TRANSBEAM UPPER CAP IS CORRODED. MAJOR REPAIR ACCOMPLISHED. REPAIRED TRANSBEAM WITH NEW SECTION AND SPLICE ANGLES.

Source: SDR 2002UALA00492
OTHER · 2002-03-17 Unresolved
ATA 5315

Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

CABIN FLOORBEAM STATION 303, RBL 88 IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPAIRED FLOORBEAM NEW SECTION WITH SPLICE ANGLES.

Source: SDR 2002UALA00488
OTHER · 2002-03-14 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 852 RBL 33 TRANSBEAM CORRODED ON UPPER CAP. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICES.

Source: SDR 2002UALA00461
OTHER · 2002-03-14 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 800 LBL 11 TRANSBEAM UPPER CHORD IS CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED TRANSBEAM AND SPLICES.

Source: SDR 2002UALA00462
OTHER · 2002-03-14 Unresolved
ATA 5311

Part: FRAME — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles

BODY STATION 287 RBL 88 CHORD CORRODED AT CHORD LOCATED AT R-1 DOOR. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW CHORD.

Source: SDR 2002UALA00460
OTHER · 2002-03-08 Unresolved
ATA 5330

Part: SKIN — GOUGED · airframe 43,180 hrs · 6,953 cycles

BODY STATION 785 STRINGER 1-2 FUSELAGE SKIN IS GOUGED BODY STATION 785 LEFT HAND SIDE, STRINGER 1L-2L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER REPAIR.

Source: SDR 2002UALA00405

2001

SMOKE/FUMES/ODORS/SPARKS · 2001-05-20 Unresolved
ATA 2121

Part: FAN — ODOR (COCKPIT) · airframe 39,783 hrs · 6,375 cycles

CREW EXPERIENCED BURNING ODOR IN COCKPIT AND FOUND EQUIP EXHAUST FAN 1 CB TRIPPED.

Source: SDR 2001UALA00783
FLUID LOSS; WARNING INDICATION; ENGINE STOPPAGE · 2001-05-07 Unresolved
ATA 7310

Part: ENGINE — LEAKING (NR 1) · airframe 39,736 hrs · 6,368 cycles

NR 1 ENGINE SHUTDOWN DUE CONFIRMED FUEL LEAK. DIVERTED SDF.

Source: SDR 2001UALA00718
OTHER · 2001-04-17 Unresolved
ATA 5313

Part: STRINGER — DAMAGED (FUSELAGE) · airframe 39,516 hrs · 6,324 cycles

STRINGER 32R AT BS 1200 HAS A FIGURE EIGHT SHAPED FASTENER HOLE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHEDREPAIRED PER SRM 51-20-07 AND SRM 53-00-01.

Source: SDR 2001UALA00538
OVER TEMP · 2001-02-22 Unresolved
ATA 2432

Part: GROUND WIRE — DAMAGED (BATTERY) · airframe 38,872 hrs · 6,203 cycles

APU BATTERY GROUND GD3072DC OVERHEATED. INSULATION BLANKETS HEAT DAMAGED. *S/D* ACCOMPLISHED DETAILED VISUAL INSPECTION OF ALL EFFECTED WIRE BUNDLES AND INSTALLATIONS LOCATED IN E6-1 SHELF AND P49 PANEL. ALL WIRING CHECKED OK, EXCEPT APU BATTERY GROUND WIRE. REPLACED APU BATTERY GROUND BRACKET (P/N 287T0152-4), APU BATTERY GROUND WIRE W1048-007-1/0 AND GROUND GD3072DC HARDWARE.

Source: SDR 2001UALA00142

2000

ENGINE FLAMEOUT; WARNING INDICATION · 2000-01-27 Unresolved
ATA 7230

Part: BLADE — CRACKED (COMPRESSOR) · airframe 34,102 hrs · 5,342 cycles

RIGHT ENGINE SUFFERED A FLAME-OUT DURING INITIAL CLIMB FROM FL330 TO FL370. TWO RESTARTS ATTEMPTED WITH NO HELP. ENGINE SURGED AT FL330 NO VIBRATION. AFTER LANDING MECHANIC FOUND METAL IN TAILPIPE. *S/D* C5 BLADE FAILURE DUE TO IMPACT DAMAGE. BLADE WAS IMPACTED BY MATERIAL LIBERATED BY C5 DISK INTEGRAL KNIFE EDGE AIRSEAL. PRATT & WHITNEY SERVICE BULLETIN 72-653 CORRECTS THIS FAILURE MODE BY REMOVING C5 KNIFE EDGE SEAL FORWARD LAND.

Source: SDR 2000UALA00041

1999

FLT CONT AFFECTED; WARNING INDICATION · 1999-09-27 Unresolved
ATA 2750

Part: RETRACT MECH — MALFUNCTIONED (TE FLAPS)

ON FLAP RETRACTION DURING TAKEOFF (FLAPS 5), WHEN FLAPS 1 WAS CALLED FOR FLAPS STUCK AT ABOUT 3.5 DEG. TE FLAP DISAGREE EICAS MESSAGE WITH MASTER CAUTION PROCEDURE ON 7-43 WAS ACCOMPLISHED PER FLIGHT MANUAL.

Source: SDR 99UAL900496
ELECT. POWER LOSS-50 PC; WARNING INDICATION; FLUID LOSS · 1999-09-27 Unresolved
ATA 4940

Part: STARTER — DEFECTIVE (APU)

APU AUTO SHUTDOWN WITH 'APU OIL QTY' EICAS MSG DISPLAYED. DIVERTED TO ASU . *S/D* APU STARTER WAS FOUND LEAKING WHICH CAUSED THE LOP SHUTDOWN. REPLACED APU STARTER PER ENGINEER'S UPDATE. ALSO, REPLACED GEARBOX SHUTOFF VALVE AS A PRECAUTIONARY ACTION. SERVICED APU WITH OIL AND TESTED OK WITH NO FURTHER LEAKS AND OPERATION BACK TO NORMAL.

Source: SDR 99UAL900494
ELECT. POWER LOSS-50 PC; WARNING INDICATION · 1999-09-12 Unresolved
ATA 2421

Part: IDG — INOP (LEFT)

AIRCRAFT DISPATCHED WITH LT INTEGRATED DRIVE GENERATOR (IDG) INOP. APU AUTO SHUTDOWN CAUSING APU GENERATOR AND UTILITY BUSSES TO TRIP. FLIGHT DIVERTED TO MSY. REPLACED LT IDG. SHOP FOUND CONTAMINATION IN IDG SYSTEM.

Source: SDR 99UAL900470

1997

OTHER · 1997-12-01 Unresolved
ATA 7230

Part: COMPRSSOR — DETERIORATED (RT ENGINE)

RIGHT ENGINE COMPRESSOR STALL. RETURN TO FIELD. ENGINE WAS NOT SHUT DOWN, OVERWEIGHT LANDING. *S/D* ENGINE SURGED ON TAKEOFF DUE TO GENERAL DETERIORATION OF THE HIGH PRESSURE COMPRESSOR AND EXCESSIVE BLADE TIP CLEARANCES. ENGINE WAS REPLACED.

Source: SDR 97UAL900851

1996

SMOKE/FUMES/ODORS/SPARKS · 1996-07-17 Unresolved
ATA 2530

Part: OVEN — SMOKING (GALLEY)

USED FIRE EXTINGUISHER FOR SMOKE AND FUMES FROM GALLEY OVEN. FOUND MELTED PLASTIC MATERIAL ON HEATING ELEMENT GRILL IN OVEN. OVEN OPERATED NORMALLY AFTER PLASTIC MATERIAL WAS REMOVED.

Source: SDR 96UAL900550
FALSE WARNING · 1996-07-15 Unresolved
ATA 5270

Part: DOOR LIGHT — ILLUMINATED (CARGO DOOR)

AIRCRAFT RETURNED TO IAD DUE TO CARGO DOOR LIGHT. *S/D* BUILT IN TEST EQUIPMENT INDICATED LOGIC CARD 3 FAILED IN THE PROXIMITY SWITCH ELECTRONIC UNIT. REPLACED LOGIC CARD, OPERATIONS CHECK NORMAL.

Source: SDR 96UAL900535

1995

WARNING INDICATION · 1995-04-26 Unresolved
ATA 7260

Part: BEARING — FAILED (NR 2 GEAR BOX)

OIL FILTER BY-PASS LIGHT FOR THE NUMBER TWO ENGINE CAME ON, CREW BROUGHT BACK THROTTLE TO IDLE. SHORTLY, THEREAFTER THE NUMBER TWO ENGINE FLAMED-OUT. ANGLE GEARBOX BEARING FAILED.

Source: SDR 95UAL767016
WARNING INDICATION · 1995-02-17 Unresolved
ATA 8012

Part: VALVE — MALFUNCTION (STARTER)

STARTER VALVE, AND STARTER SEQUENCE LIGHT ILLUMINATED DURING FLIGHT. AIRCRAFT RETURNED TO FIELD. UNABLE TO FIND FAULT WITH VALVE. OVERHAULED IT AS A PRECAUTION AND RETURNED TO STOCK.

Source: SDR 95UAL767007