N652UA
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
303 reports on file, 1995-02-17 – 2026-10-25.
Part: PIN — SHEARED (NR 3 LATCH) · airframe 134,333 hrs · 20,350 cycles
LEFT OVERWING ESCAPE SLIDE DOOR LATCH NR 3 FOUND NOT FUNCTIONING. RETAINING PIN FOUND SHEARED. LATCH REMOVED IAW AMM 25-65-09-004-001 AND REPLACED IAW AMM 25-65-09-404-007. OPS TESTED GOOD. OVERWING SLIDE DOOR LATCH INSPECTED AND CONFIRMED FITTED IAW AMM 25-65-09-404-007.
Part: RECEIVER — FAULTY (RIGHT) · airframe 134,173 hrs · 20,328 cycles
NO LAND 3 ON ASA PERFORMED MCDP TEST 30, FOUND NO INFC FCC ILS BUS R, AND ILS R FAIL. REQUESTING MEL 3431J, DDP FOLLOWED. DISPATCH DESK: 11 NAME: BNC DATE: 05-OCT-26- 3431J APPROVED DEFERING PER MEL 3431J, DDP FOLLOWED. *DM* AFTER DOING BITE 22-02 TASK 801, PLEASE UPDATE LOG WITH FINDINGS SO PARTS CAN BE ORDERED. THANKS RIGHT MMR LRU FAILED. LEFT AND RIGHT MMR SWAPPED AND FAULT FOLLOWED. MMR LEFT AND RIGHT REINSTALLED TO ORIGINAL POSITION. NEEDS TO REPLACE RIGHT MMR PER AMM34-31-01/401. FIM TASK 22-02-00-815-801. MMR LRU PART REPLACE AS SHIPSETS PER IPC 34-31-01-50A AND EC 3431-0144C. LOG STILL ON MEL STATUS. REPLACED RIGHT MMR BOX REF AMM 34-31-01
Part: CARBON SEAL — LEAKING (NR 2 ENGINE)
DURING CRUISE THE A/C FACE RT OIL PRESSURE LT INTERMITTENT ILLUMINATION AND RT ENG QTY INDICATION 0. OIL PRESS FLUCTUATES DOWN 1 TO 27 TEMP NORMAL. CREW REPORTED THAT APPROXIMATELY TWO HOURS PRIOR TO ARRIVAL, INTERMITTENT ENG2 OIL PRESSURE WARNING INDICATIONS WERE OBSERVED, ACCOMPANIED BY LOW AND FLUCTUATING OIL LEVEL. ENG2 OIL SERVICING CARRIED OUT, 18 CANS OF OIL WERE USED. VISUAL INSPECTION OF THE ENGINE C/OUT WITH NO OBVIOUS OIL LEAKS INITIALLY IDENTIFIED. ENG2 DRAIN MAST CONNECTIONS REMOVED AND PLASTIC BAGS INSTALLED TO ASSIST IN LOCALIZING A POTENTIAL OIL LEAK. EGR PERFORMED. OIL LEAK IDENTIFIED ORIGINATING FROM THE PMA CARBON FIBRE SEAL ON ENG2. TOMC INFORMED, AND AIRCRAFT DECLARED AOG. NO SPARE PARTS OR REQUIRED TOOLING AVAILABLE30.06. FIELD TEAM ARRIVED - READY TO REMOVE CARBON FIBRE FROM PMA. CONTINUED TO REMOVE THE SPACER ON THE SHAFT, RE-INSTALLATION OF THE SPACER INSIDE OF THE GEARBOX & PMA 01.07 ALL ACCESSES REINSTALLED AND ENGINE COWLS CLOSED. EGR TEST AND LEAK CHECK PERFORMED SATISFACTORY. NO LEAK. EPDSC PERFORMED. AIRCRAFT READY FOR DEPARTURE.
Part: ENGINE — FAULTED (NR 2) · airframe 132,708 hrs · 20,136 cycles
RT ENG OIL PRESS ZERO SHUT DOWN IN FLIGHT HAD COMP STALLS AND FLAMES REPORTED REFERENCE LOG PAGE 9027944 FOR # 2 ENGINE REPLACEMENT REMOVED AND REPLACED # 2 ENGINE AS PER TASK CARD 64-7100-1-0011 AND 76-0571-8-0015. RAN ENGINE, ALL CHECKS GOOD AND NO LEAKS NOTED
Part: DRIVE UNIT — BURNED (ZONE 100) · airframe 131,964 hrs · 20,041 cycles
FWD CARGO AFT PALLET PDU 12L FOUND INOP. CB C173 IN PANEL P35 FOUND TRIPPED. ALL PDUS ON AFT PALLET ARE AFFECTED. UPON FURTHER INVESTIGATION PDU 12L CIRCUIT BOARD FOUND BURNT. PDU 12L REQUIRES REPLACEMENT. PDU12L REPLACED IAW AMM: 25-53-01. OPERATIONAL CHECK SATIS.PARTS USED: 64-2553-3-0160,QTY :1
Earlier reports · 1995–2025 · 298 reports
2025
Part: HOUSING — BROKEN (ZONE 200) · airframe 129,965 hrs · 19,779 cycles
31F EPL HOUSING BROKEN REPLACED BROKEN HOUSING WITH NEW REF CMM 25-23-52. TESTED EMERGENCY LIGHTS REF AMM 33-51-00-715-019-001. OPS CHECK OK
Part: BRACKET — DAMAGED (ZONE 200) · airframe 129,858 hrs · 19,765 cycles
SEAT 31F EMERGENCY PATH LIGHT BRACKET DAMAGED. BRACKET REFITTED IAW B/E PINNACLE CMM 25-21-52.
Part: PCB — FAULTED (EICAS) · airframe 129,851 hrs · 19,764 cycles
EICAS GEAR NOT DOWN WITH CONFIG ANUNCIATION OCCURED WHEN NOSE GEAR TOUCHED DOWN. CARRIED OUT FIM 31-51 FAULT TREE 812 AND PSEU BITE AS PER FIM 32-09 FAULT TREE 803, PSEU NO PREVIOUS SECTOR FAULTS AND CURRENT FAULTS CLEAR PSEU CLEARED. CARRIED OUT FIM 31-51 FAULT TREE 805 AND FOUND LANDING CONFIGURATION WARNING MODULE FAULTY. REMOVED AS PER AMM TASK 31-51-04-004-133, INSTALLED AS PER AMM TASK 31-51-04-404-014. WEU CARD MODULE TEST CARRIED OUT AS PER AMM TASK 31-51-04-724-154, TEST PASSED EICAS WARNING CLEARED AND ANNOUNCITOR EXTINGUISHED.
Part: SAFETY WIRE — BROKEN (OXYGEN BOTTLE) · airframe 129,210 hrs · 19,681 cycles
CREW OXYGEN CYLINDER VALVE SAFTEY WIRE IS BROKEN, CHECK CORRECT VALVE POSITION AND RE-SAFTEYWIRE. CREW O2 BOTTLE FOUND IN AN UNSAFE CONDITION. RECTIFICATION OUTSTANDING VALVE POSITION CONFIRMED CORRECT, SAFETY WIRE RE APPLIED AND SECURED. WRT AMM 35-11-00-206-233.
Part: SIGN — DETACHED (ZONE 200) · airframe 129,068 hrs · 19,662 cycles
DOOR 1L EMERGENCY EXIT SIGN FELL OFF RESECURED EMERGENCY EXIT LIGHT LENS COVER AT DOOR 1L REF AMM 33-51-01-402-030. ADDED SDR DATA
Part: IDG — FAULTED (NR 2) · airframe 128,576 hrs · 19,597 cycles
RT GEN DRIVE LIGHT ILLUMINATED.FL310 35 MINS INTO FLIGHT.. UPDATE WITH EICAS MESSAGE, R GEN DRIVE HIGH IDG RISE TEMP UPDATE WITH BPCU INFO REMOVED AND REPLACED #2 ENGINE IDG AS PER AMM 24-11-01-404-001-006. OPS CHECK GOOD. FOUND OIL LEAKING FROM IDG SERVICE OVERFLOW COUPLING 76-2411-3-0003. C/W REQUIRED IDT INSPECTION OF IDG FEEDER CABLE INSTALL REFF AMM 24-11-01. REMOVED AND REPLACED E2 IDG SERVICE OVERFLOW DRAIN COUPLING AS PER AMM 24-11-03. LEAK CHECK GOOD.
Part: BEAR STRAP — CRACKED (ZONE 200) · airframe 127,998 hrs · 19,521 cycles
R1 FWD SERVICE DOOR AFTER CORNER - DURING HFEC OPEN HOLE INSPECTION WAS FOUND HOLES WITH CRACK INDICATION.UPDATE GENERATED DUE REPAIR ACCOMPLISHMENT CLASSIFIED AS MAJOR REPAIR. (CHANGE ATTRIBUTES). UPDATE GENERATED DUE REPAIR ACCOMPLISHMENT CLASSIFIED AS MAJOR REPAIR. THE FUSELAGE SKIN 1R DOOR CUTOUT AFTER LOWER CORNER BEAR STRAP WAS REPAIRED AT GIG. THE REPAIR IS A PERMANENT SOLUTION WITH INSPECTION REQUIREMENTS. ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF LATEST REVISION OF EC/RA 5310-08568 ON OR BEFORE THE AIRCRAFT REACHES 37.500 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 3.000 FLIGHT CYCLES. REF ECRA 5310-08568: ACCOMPLISH INSPECTION EQUIREMENTS PER PART 2 OF LATEST REVISION OF EC/RA 5310-08568.
Part: BEAR STRAP — CRACKED (ZONE 200) · airframe 127,998 hrs · 19,521 cycles
L1 FWD ENTRY DOOR AFTER CORNER - THERE ARE TWO CRACKS AT 10 AND 4 O'CLOCK IN THE LOWER ON THE AFTER CORNER. UPDATE GENERATED DUE REPAIR TO BE ACCOMPLISHED CLASSIFIED AS MAJOR. THE FUSELAGE SKIN 1R DOOR CUTOUT AFTER LOWER CORNER BEAR STRAP WAS REPAIRED AT GIG. THE REPAIR IS A PERMANENTSOLUTION WITH INSPECTION REQUIREMENTS. ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF LATEST REVISION OF EC/RA 5310-08566 ON OR BEFORE THE AIRCRAFT REACHES 37.500 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 3.000 FLIGHT CYCLES. REF ECRA 5310-08566: ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF LATEST REVISION OF ECRA 5310-08566 ON OR BEFORE THE AIRCRAFT REACHES 37.500 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 3.000 FLIGHT CYCLES.
Part: FLOOR SUPPORT — DAMAGED (ZONE 200) · airframe 127,998 hrs · 19,521 cycles
PAX COMPARTMENT FLOOR PANEL - IT NECESSARY TO PERFORM A REPAIR ON THE FLOOR BEAM LOCATED RBR 54.75 BETWEEN STA 785.9 / STA 933 DUE TO THE EXISTING REPAIR IN THE AREA HAVE NOT THE HOLES OF FLOOR PANEL ( P74, P80, P81 AND P82) AS PER NR: 002594240, NR: 002594252, NR: 002594246 AND NR: 002594234. ACCOMPLISHED REPAIR ON THE FLOOR BEAM AS PER SRM 53-00-51-2R-3. PERFORMED BY: U422642, U419664, U426239, U395678 NECESSARY MORE INFORMATIONS ABOUT THE ESFR. INCLUDED ESFR INFORMATIONS ESFR INFORMATION HAS ADD AND APPROVED. THE REPAIR HAS BEEN PERFORMED IN REF SRM 53-00-51-2R-3 UNDER NR2594240, NR2594252, NR2594246, NR2594234
2024
Part: LENS — DETACHED (ZONE 200) · airframe 126,927 hrs · 19,379 cycles
OVERWING EXIT SIGN AT AICRAFT RIGHT IS HANGING DOWN. OVERWING EXIT SIGN R-H SIDE CEILING POSITION LENS COVER REFITTED AND SECURED PER AMM 33-51-01
Part: TRANS RECTIFIER — FAULTED (ZONE 100) · airframe 125,076 hrs · 19,132 cycles
767 FUEL FEED SYSTEM HEALTH CHECK - LH FWD BOOST PUMP - VOLTAGE INBALANCE OF FWD LH FUEL PUMP OUT OF TOLERANCE. LH TRANSFORMER RECTIFIER UNIT REPLACED AS PER AMM 24-32-01-004-001 AND 24-32-01-404-005. LH TRU OP-CHECK TEST OK, FWD LH FUEL PUMP VOLTAGE INBALANCE NOW WITHIN LIMITS. LH TRANSFORMER RECTIFIER UNIT REPLACED AS PER AMM 24-32-01-004-001 AND 24-32-01-404-005. LH TRU OP-CHECK TEST OK, FWD LH FUEL PUMP VOLTAGE INBALANCE NOW WITHIN LIMITS.
Part: FMC — FAULTED (LEFT) · airframe 124,676 hrs · 19,077 cycles
LEFT FMC FROZE. UNABLE TO INPUT COMMAND. LEFT AIRSPEED BUG +/- 30 KNOTS FROM STEP F (7) TO COMPLETION (TEST FLIGHT MANAGEMENT COMPUTER). REMOVED AND REPLACED LEFT FLIGHT MANAGEMENT COMPUTER AS PER AMM 34-61-01-024-001-001 AND AMM 34-61-01-424-005-001 UP TO STEP F (6). ALL SOFTWARE FOR LEFT FMC IS UP TO DATE AND CORRECT. NEW NAV DATA NEEDS TO BE INSTALLED AND ALSO AMM 34-61-01-424-005-001 COMPUTER, FLT M OFF 19-3461-9-0004 9495 ON 19-3461-9-0004 5565 SEE LOG PAGE 827379 FOR NAV DATA INSTALL COMPLIED WITH TEST FLIGHT MANAGEMENT COMPUTER FROM F (7) TO COMPLETION ALL CHECKS GOOD 34-61-01-424-005-001.
Part: TIRE — LOW PRESSURE (NR 2 MLG) · airframe 124,505 hrs · 19,053 cycles
FOUND #2 MLG TIRE PRESSURE WAS UNDER REINFLATION RANGE. REMOVED AND REPLACED #2 TIRE. AMM 32-45-01.
2022
Part: DOOR — BINDING (COCKPIT) · airframe 117,138 hrs · 18,057 cycles
COCKPIT DOOR DIFFICULT TO CLOSE APPEARS TO BE BINDING ON THRESHO LD TIGHTENED COCKPIT DOOR SILL, OPS CHECK OK.
2021
Part: AILERON SYS — MALFUNCTIONED (RT) · airframe 116,079 hrs · 17,888 cycles
ON APP W/FLAPS 15 - RT AIL DROOPED FULL AND L AIL AT HALF. TE DISAGREE EICAS. FOR THE RIGHT INBD AILERON IS BYPASSING OR A PROBLEM WITH INBD AILERON DROOP MECHANISM. ITEM LOCKED FOR FURTHER CHECKS. UNLOCKED FOR L/P UPDATE LOGPAGE LOOCKED AS REQ''D. RIGHT INBD AILERON POSITION INDICATES LOWER THAN LEFT INBD SUSPECT INBD CENTER PCA IS BYPASSING. ISOLATED BY CYCLING CENTER AILERON WITH FLAPS SET TO 15. RIGHT INBD AILERON ALSO CONTINUES & RIGHT HYDRAULICS OFF & ON WHILE LISTENING AND FEELING INBD TO DROP FULLY DOWN WITH HYDRAULICS OFF WHILE LEFT INBD AILERON PCA, WHICH WAS EMITTING A HIGH FREQ SOUND & VIBRATING, WHILE THE REMAINS AT LAST POSITION. ACCOMPLISHED FIM 27-11 TASK 807 FOR OTBD PCA SOUNDED & FELT NORMAL. AILERON DROOP PROBLEM, NO FAULTS FOUND. SUSPECT ONE OF THE PCA''S UNLOCKED FOR MAINTENANCE UPDATE. LOG PAGE LOCKED AFTER MAINTENANCE UPDATE. UNLOCKING L/P FOR MAINTENANCE UPDATE. LOG PAGE LOCKED AFTER UPDATE. SDR IS FLAGGED DUE TO EMERGENCY LANDING DECLARED BY THE FLIGHT CREW.
Part: NONE — NONE (NA) · airframe 116,063 hrs · 17,885 cycles
CREW REPORT, L MAIN FUEL TANK AND TOTAL QTY INDICATION READING BLANK LEFT FLIGHT DECK FUEL QTY INDICATOR DEFERRED PER B767-300 MEL LEFT FLIGHT DECK FUEL QTY INDICATOR DEFERRED PER B767-300 MEL 2841R.M PROCEDURE COMPLIED WITH. REF LOG PAGE 7401962 FOR 2841R. M PROCEDURE COMPLIED WITH. REF LOG PAGE 7401962 FOR SECOND DEFERRAL FOR TOTAL FUEL QTY INDICATION. SECOND DEFERRAL FOR TOTAL FUEL QTY INDICATION. DISPATCH DESK: 3361 NAME: G.D. OK TO DEFER L MAIN TANK QTY INDICATION PER MEL.
Part: TRANSMITTER — OUT OF ADJUST (TE FLAP SYS) · airframe 114,926 hrs · 17,701 cycles
TE FLAPS ASYM FLAPS STUCK LESS THAN 5 INTERROGATED FSEU ...MSG "TE ASYM XMT 1-8". FAULT CODE 27-51083. FLAPS LOCKED OUT. WILL NOT MOVE IN ALT AS WELL AS HYD. TROUBLESHOT PER FIM 27-51 TREE 811 AND ADJ #8 TRANSMITTER PER AMM 27-51-45-822-161. GROUND CK GOOD ADD EMP:352640
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 114,637 hrs · 17,648 cycles
P61 SQUIB TEST FOUND LH & RH SPOILER AND SLIDE LIGHT INOP, REF NRC 9130152 TROUBLESHOOTING CARRIED OUT FOUND R/H AND L/H POWER SUPPLY BATTERIES WAS POWER LOW,R/H AND L/H OFF WING SLIDE POWER SUPPLY ASSY AND BATTERIES REPLACED AND SQUIB TEST TEST CARRIED OUT RESU LT NORMAL AS PER FIM TASK 25-65 FAULT TREE818,TASK25-65,FAULT TREE 820,AMM 25-65-17 AND AMM 26-65-00. ADD EMP:V919559 FORM 44-0008 ITEM 1 TO 4 ACCOMPLISHED
Part: SKIN — CORRODED (BS 1219 S38L) · airframe 114,637 hrs · 17,648 cycles
B767-06-3-7022 - FX STA 1219 S38L AREA FOUND SUSPECT CORRODED. R EF N/R L/P 9130407 GENERATE A DIP FOR INSPECTION REQUIREMENT AS PER EC/RA 5360-0160 3 REV-PART 2 ADD EMP:V896876 FUSELAGE SKIN STA1219 STR38L INTERIM REPAIRED AS PER EC/RA5360-0 1603 REV-PART1 ATTACHED FORM44-0008 ITEM 1 TO ITEM 38 ACCOMPLISH ED GENERATED A DIP ACCOMPLISHED INSPECTION PER CATEST REV OF EC/ RA5360-01603 PART2 BEFORE REACHING 37,500 TOTAL FLIGHT CYCLES. R EPEAT THE INSPECTION AT INTERNAL NOT TO EXCEED ADD EMP:V912779 9000 FLIGHT CYCLES, THEREAFTER INSPECTED AND APPROVED BY HX146606 ADD EMP:V898549
2020
Part: WINDOW — LEAKING (L2) · airframe 114,451 hrs · 17,601 cycles
CAPTAIN STATED LOUD SQUEEL DEVELOPED AT FL380 AND CABIN PRESSURE AT 6.5. DESCENDED TO FL 320 AND CABIN PRESSURE AT 6.0, NO HELP. SQUEEL SILENCED AT FL260 AND CABIN PRESSURE AT 1900. SOUND COMING FROM FWD SIDE OF THE CAPTAIN`S SLIDING WINDOW FROM TOP TO 1/2 WAY DOWN FWD SIDE. INSPECTED WINDOW, NO DEFECTS NOTED. PRESSURIZED ACFT NOTED NO NOTICABLE AUDIBLE SQUEELING FROM EITHER NR 2 WINDOW INSIDE. THE OUTSIDE HAD SMALL AMOUNT OF BUBBLES USING WATER AND SOAP SOLUTION IN THE UPPER FWD, LOWER FWD AND LOWER AFT CORNERS, BUT COULD NOT FEEL ANY AIR LEAKAGE IAW AMM 05-51-24. REPLACED THE L2 FLIGHT DECK WINDOW IAW AMM. OK FOR SERVICE.
2019
Part: LIGHT — INOPERATIVE (FWD GALLEY) · airframe 112,995 hrs · 17,383 cycles
PER TASK CARD 63-3310-1-7300 FWD GALLEY SIDE 2EA EMRE LT INOP REF BSH N0052 REPLACED FWD GALLEY SIDE 2EA EMER LT AND LT TEST R ESULT IS NORMAL AS PER AMM 33-51-05 R128.
Part: LIGHT — CRACKED (ROW 6K) · airframe 112,995 hrs · 17,383 cycles
REF TO BSH N0481 CABIN 6K AISLE EMER LT ASSY HAVE CRACK REF BSH N0481 REPLACED 6K AISLE EMER LT ASSY AND LT TEST RESULT IS NORMAL AS PER AMM 33-51-05 R128.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 112,995 hrs · 17,383 cycles
PER TASK CARD 63-3350-1-7100 38R AISLE EMERGENCY LIGHT AT CEILIN G PANEL DO NOT COME ON REF TO BSH N0170 REPLACED 38R AISLE EMER LT AT CEILING PANEL AND LT TEST RESULT IS NORMAL AS PER AMM 33-51-05 R128.
Part: LIGHT — INOPERATIVE (SEAT 38) · airframe 112,995 hrs · 17,383 cycles
PER TASK CARD 63-3350-1-7100 38F EMER LT INOP REF TO BSH N0125 REPLACED 38F EMER LT AND LT TEST RESULT IS NORM AL AS PER AMM 33-51-05 R128.
Part: CONNECTOR — BROKEN (CABIN) · airframe 112,954 hrs · 17,378 cycles
CROSS AISLE FLOOR MARKER LOOSE BETWEEN SEATROW 20DEF AND 21DEF. LIGHT TEST FAILED ON CROSS AISLE FLOOR MARKER AND 4 OVERWING EXITS LOWER EXIT SIGNS THESE EMERGENCY LIGHTS CAN ONLY BE SWITCHED ON FROM COCKPIT. NOT FROM FA PANEL TEST SWITCH. FOUND SOLDERING OF CONNECTOR OF LIGHT STRIP BROKEN. REPAIRED SOLDERING IAW SWPM 20-12-01. TEST EMERGENCY LIGHTS IAW AMM 33-51-10-712-130. ALL SATIS.
Part: PANEL — UNSECURE (CABIN) · airframe 111,508 hrs · 17,192 cycles
ROW 27, 28 DEF SEATS O2 PANEL OPENED DURING TAKE OFF. PER CREW TOMC MO LOG#3251826 HAS BEEN CREATED BY CREW. TOMC MO FOUND PSU PANEL AT ROW 27 TO BE IN THE UNLATCHED AND DOWN POSITION. RESTOWED PSU PANEL IAW AMM 25-23-01-404-005. OPS CHECKED GOOD.
2017
Part: LIGHT — DAMAGED (ROW 21) · airframe 106,355 hrs · 16,491 cycles
EMERGENCY EXIT LIGHT AT ROW 21 CENTER HAS DAMAGE. REPLACED THE POWER SUPPLY AND LIGHT . CHECKED OK.
Part: LIGHT — BROKEN (CABIN) · airframe 104,424 hrs · 16,227 cycles
ROWS 4,5,6 SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTS DO NOT WORK WITH ALL EMERGENCY SWITCH IN CABIN AND INCLUDING P5 PANEL SWITCH. TROUBLESHOT BATTERY PACK FUSE SHORT PER WDM 33-51-15. FOUND ROW 5D SEAT EEL ASSY BROKEN REPLACED OPS CHECK GOOD.
Part: WIRE — BURNED (CIRCUIT BREAKER) · airframe 104,313 hrs · 16,209 cycles
CREW REPORTED AFTER REACHING CRUISE ALTITUDE, NO POWER TO AFT GALLEYS. NO CIRCUIT BREAKERS TRIPPED, ALL GALLEY EQUIPMENT OFF. RESET UTILITY BUSS, GALLEY POWER RESTORED. JUST PRIOR TO TURNING GALLEY APPLIANCES ON, THE FLT ATTENDANT REPORTED AN ACRID ODOR FROM AFT GALLEY CIRCUIT BREAKER PANEL. G ALLEY POWER SECURED, NO FURTHER ODOR FOUND. TWO WIRES WITH BLACK INSULATON AT TERMINAL ENDS AT CIRCUIT BREAKER C404 AT AFT GALLEY LEFT SIDE CIRCUIT BREAKER PANEL. TERMINATED THE WIRES AND REMOVED AND REPLACED C404 CIRCUIT BREAKER. ALL WORK ACCOMPLISHED IAW SWPM 20-30-11 AND WDM 25-31-23. APPLIED POWER TO AFT GALLEY AND NO ISSUES NOTED.
Part: BLADES — DAMAGED (NR 1 ENGINE) · airframe 104,280 hrs · 16,204 cycles
DAMAGE FOUND TO A FAN BLADE ON NR 1 ENG, SUSPECT BIRD INGESTION. REMOVED 2 EACH BLADES BLADE NUMBER 12 AND BLADE NUMBER 31 BLADE IN NUMBER 12 POS S/N 3505 OFF S/N ON 9068 BLADE IN POS 31 S/N OFF 3444 S/N ON 9050 REF AMM TASK 72-31-02-004-001-N00 AND TASK 72-31-02-404-021-N00.
Part: OVEN — FAILED (GALLEY) · airframe 103,993 hrs · 16,166 cycles
OVEN 106 FWD BURNS FOOD AND SMOKES. TEMP UNCONTROLABLE. FIRE HAZARD. R & R THE OVEN. ALL OPS OK.
Part: CONTROLLER — FAULTY (OVEN) · airframe 103,986 hrs · 16,165 cycles
OVEN 106 OVERHEATS WHILE COOKING. BURNS FOOD AND SMOKES. TEMP CONTROL UNCONTROLLABLE. REMOVED AND REPLACED OVEN TEMP CONTROLLER. OVEN OPERATES NORMAL WITH CONTROLLING (CYCLING) TEMPERATURE.
Part: OVEN — ODOR (GALLEY) · airframe 103,558 hrs · 16,108 cycles
FORWARD GALLEY OVEN 106 HAS ELECTRICAL BURNING SMELL. REMOVED AND REPLACED OVEN POS 106 IN FWD GALLEY. OPS CHK GOOD.
Part: BATTERY PACK — FAULTY (EMERGENCY LIGHTS) · airframe 103,102 hrs · 16,045 cycles
R2 DOOR EMERGENCY EXIT LIGHT AT FWD LOWER POSITION REMAINS ILLUMINATED WITH EMERGENCY LIGHT SWITCH IN ANY POSITION . PERFORMED T/S IAW WDM 33-51-14. FAULTY BATTERY PACK M1556 CONFIRMED. R & R THE BATTERY PACK IAW AMM 33-51-07. OPS OK.
Part: SIGN — MALFUNCTIONED (EMERGENCY LIGHTS) · airframe 103,096 hrs · 16,044 cycles
R2 DOOR LOWER FWD EMERGENCY EXIT SIGN ILLUMINATED WITH SWITCH ON OR OFF. REMOVED AND REPLACED LOWER FWD EMERGENCY MAKER EXIT SIGN, OPS CHECK GOOD.
2016
Part: LIGHT — INOPERATIVE (CABIN) · airframe 101,964 hrs · 15,889 cycles
R1 AND LEFT O/W SECOND FROM AFT EMERGENCY LIGHTS ARE INOP. RELAMPED OPS CHECK GOOD REF AMM 33-51-06.
Part: SKIN — CRACKED (BS 1197) · airframe 101,038 hrs · 15,754 cycles
PREVIOUS BLEND OUT FOUND ON FUSELAGE STA 1197+66 AND 1197+88 STR 35L. HFEC INSPECTION RESULTED IN A CRACK MEASUES 0.025. SKIN THICKNES S IS 0.160. REPAIRED AS PER SRM 53-00-01, REPAIR 14, FIG 201, TABLEII. PAGE 205.THIS IS A CATEGORAY B REPAIR INSPECTION REQUIR MENTS IS 37,000 FLIGHT CYCLES FROM DATE OF DELIVERY, OR 6,000 CYCLES FROM DATE OF REPAIR INSTALLATIONS WHICH EVER IS GREATER. AND 12,000 FLIGHT CYCLES INTERVAL.
Part: STRUT — CRACKED (LT NACELLE) · airframe 101,038 hrs · 15,754 cycles
SUPPORT TASK EA 5100-02450 OP4. LT STRUT NAC STA 156 WL 145 FOUND REPAIR AROUND DRAIN HOLE. REMOVED EXISTING REPAIR L/H STRUT NAC STA 156, CRACK MEASURED 0.080. REPAIRED AS PER SRM 54-53-01, REPAIR 10, FIG 201, REPAIR B.
Part: SPAR — CRACKED (NR 2 PYLON) · airframe 101,038 hrs · 15,754 cycles
NR 2 PYLON UPPER SPAR WEB FOUND CRACKED AT NAC STA 175. FILLER FABRICATED IAW ECRA 5410-01834 PART 1 INTERIM REPAIR, ALL REPAIR PARTS INSTALLED TO WEB REPAIR AREA, FILLET SEAL EDGE APPL IED PER ECRA 5410-01834 PART 1, HFEC INSP CARRIED OUT IAW NTM PART 6, 51-00-19, RESULT NO CRACK FOUND.
Part: SKIN — CRACKED (NR 2 NACELLE) · airframe 101,038 hrs · 15,754 cycles
NR 2 PYLON PANEL 446BL CUTOUT S KIN FOUND CRACKED. REPAIRED IAW SRM 54-53-01 REPAIR 7 FIG 201 DETAIL I.
Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles
EMERGENCY EXIT LIGHT INOPERATIVE, DOOR 2 RT SILL LIGHT. REPLACED BATTERY AT M734 IAW MM 33-51-07.
Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles
EMERGENCY EXIT SIGN INOPERATIVE AT AFT GALLEY RT SIDE. REPLACED BATTERY AT M734 IAW MM 33-51-07.
Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles
EMERGENCY EXIT SIGN INOPERATIVE, JUST ABOVE & AFT OF ROW 39 RT. REPLACED BATTERY AT M734 IAW MM 33-51-07.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 99,691 hrs · 15,570 cycles
EXTERIOR EMER EXIT LIGHT INOPERATIVE, FIRST LIGHT JUST AFT OF RT WING TE ON FUSELAGE. RELAMPED. OPERATIONS CHECKED NORMAL.
Part: BATTERY — DISCHARGED (CABIN) · airframe 99,691 hrs · 15,570 cycles
EMERGENCY EXIT LIGHTS INOPERATIVE. CEILING ABOVE ROWS 29 RT THROUGH AFT GALLEY RT SIDE. REPLACED BATTERY AT M734 IAW MM 33-51-07 PG 201.
2015
Part: SKIN — DENTED (CARGO DOOR) · airframe 94,896 hrs · 14,929 cycles
BULK CARGO DOOR, SKIN DENTED 2 PLACES ABOVE EXISTING DOUBLER. DENTS FOUND OUT OF SRM LIMITS. REMOVED DOUBLER & ENCOMPASSED INTO ONE REPAIR. REPAIRED IAW SRM 52-30-01 FIG 201 REPAIR 6. THIS IS A CAT B REPAIR.
Part: BATTERY — DISCHARGED (CABIN) · airframe 96,145 hrs · 15,100 cycles
SEAT MOUNTED EEL INOPERATIVE AT SEAT ROWS 35 RT - 39 RT. IAW WD 33 51 12 & MM 33 51 07, FOUND BATTERY M99084 BAD. CONNECTED NEW BATTERY & CHARGER TO CONNECTOR D9819P. ALL LIGHTS CAME ON.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles
FLOOR MOUNTED EEL STRIP INOPERATIVE AT MID LT LAVATORY. REPLACED BATTERY FLOOR MOUNTED EEL STRIP AT MID LT LAVATORY. OPERATIONS CHECKED NORMAL.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles
SEAT MOUNTED EMER EXIT LIGHT INOPERATIVE AT SEAT ROW 28 LT. CRIMPED FEEDER. OPERATIONS CHECKED IAW MM 33-51-00-501.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles
FLOOR MOUNTED EEL STRIP INOPERATIVE AT LT AISLE JUST FWD OF LT AFT DOOR. CRIMPED CABLE IAW SWPM 20- 30-12 & AMM 33-51-10. OPERATIONS CHECKED OK.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles
FLOOR MOUNTED EEL STRIP INOPERATIVE AT CTR SEAT ROW 19. REPLACED BATTERY FLOOR EEL STRIP AT ROW 19. OPERATIONS CHECKED NORMAL.
Part: SIGN — INOPERATIVE (CABIN) · airframe 96,145 hrs · 15,100 cycles
GREEN EMER EXIT SIGNS INOPERATIVE AT BOTH LT OVERWING EXIT DOORS. REPLACED BATTERY EXIT SIGNS. OPERATIONS CHECKED NORMAL.
2014
Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AFT PIT STATION 1285 HAS CORROSION ON J CHORD UNDER SIDE. REMOVED, FABRICATED & REPLACED STATION 1285 J CHORD PN 146T1210-20 IAW DWG 146T1210 REV C & SRM 51-40-02.
Part: SKIN — DAMAGED (NR 1 NACELLE) · airframe 94,896 hrs · 14,929 cycles
NUMBER 1 ENG LT & RT TR'S LOWER INNER AFT BIFURCATION FAIRING S SKIN FOUND PITTED DURING GSO C-16 VISIT. AFTER DAMAGE REMOVAL & BLENDING REMAINING MATERIAL IS .081 INCHES WITH .019 INCHES REMOVED, OUT OF LIMITS OF SRM 54-33-01. WORK STEPS OF ECRA 7830-02831 ACCOMPLISHED INCLUDING FPI & HFEC INSPECTION WITH NO ADVERSE FINDINGS ON INBD OR OTBD TR'S.
Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
FORWARD CGO DOOR CUT OUT SILL SUPPORT STRUCTURE CORRODED AT FS 588. R & R FWD CGO DOOR LOWER SILL PN 143T8204-1 WITH NEW SILL IAW SRM 51-40-02 & DWG 143T8513. THIS IS A PSE REPLACEMENT WITH NO INSPECTIONS REQUIRED OUTSIDE OF NORMAL MPD REQUIREMENTS. OPERATIONS CHECKED GOOD OF FWD CGO DOOR FUNCTION FIT & FAIR IAW AMM 52-33-00.
Part: WEB — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD PIT LOWER DOOR SILL BALL PANEL SUPPORT BEAM HAS CORROSION ON WEB & CHANNEL STATION 540 - 565 RBL 45. REMOVED WEB, FABRICATED WEB PN 451T2603-41 IAW DWG 451T2603 REV C. INSTALLED WEB & NEW CHANNEL PN 452T1137-23 IAW SRM 51-40- 02 & DWG 451T1602. THIS IS A REPLACEMENT WITH NO INSPECTIONS REQUIRED OUTSIDE OF NORMAL MPD REQUIREMENTS.
Part: FRAME — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR FRAME AT BS 500 RBL 15 J CHORD IS CORRODED UNDER NUTPLATES. REMOVED DAMAGED FRAME J CHORD ENTIRE LENGTH & FABRICATED & INSTALLED A NEW 143T1060-25 J CHORD IAW DWG 143T1203 REV A & SRM 51-40-02.
Part: FRAME — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR BS 632 RBL 28 FRAME J CHORD CORRODED UNDER NUTPLATES. REMOVED ENTIRE J CHORD SECTION & REPLACED WITH A NEW J CHORD PN 143T1060-29 IAW DWG 143T1209 SHEET 4 REV C & SRM 51-40-02 ON NON-ROUTINE 40976.
Part: STRINGER — DENTED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AREA AFT OF BULK CARGO COMPARTMENT LOWER BILGE STRINGER IS DENTED SEVERAL AREAS AT BS 1540 - 1560 STRINGER 36L. DENTS EXCEED SRM 53-00-03 DETAIL III LIMITS. REMOVED DAMAGED SECTION OF STRINGER 36L, FABRICATED STRINGER REPAIR CHANNEL, SPLICE ANGLES, FILLERS & INSTALLED IAW SRM 53-00-03 REPAIR 2 DETAIL IV ON NON-ROUTINE 41181.
Part: FRAME — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR STATION 544 RBL 19 FRAME J CHORD IS CORRODED UNDER NUTPLATES. REMOVED DAMAGED FRAME J CHORD ENTIRE LENGTH, FABRICATED A NEW PN 143T1060-27 J CHORD & INSTALLED IAW DWG 143T1205. CAT A PERMANENT REPAIR.
Part: FRAME — CRACKED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
BS 1263 FRAME UPPER J CHORD IS CORRODED AT NUTPLATES LBL 36. REMOVED FRAME J CHORD, FABRICATED & INSTALLED A NEW J CHORD PN 146T1209-26 IAW DWG 146T109 & SRM 51-40-02 ON NON-ROUTINE 41233.
Part: STRAP — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
WEB UPPER STRAP IS CORRODED AT NUTPLATES BS 1219, LBL 22 - LBL 30. REMOVED DAMAGED CORROSION FROM AFT PIT FRAME J CHORD AT BS 1219, MATERIAL REMAINING EXCEEDS SRM 53-00-07 LIMITS. CUT OUT DAMAGED CHORD & REPLACED ENTIRE PN 146T1060-2 CHORD IAW DWG 146T0250 REV A & SRM 51-40-05 & 51-40-02.
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 94,896 hrs · 14,929 cycles
BS 347 FLOORBEAM T CAP CORROSION REMOVED & REMAINING MATERIAL BEYOND SRM LIMITS. DAMAGED T CAP CUT OUT BETWEEN RBL 4 & RBL 87. AFTER TRIMMING THE CHORD THERE IS SHORT ED IN THE WEB DUE TO EXISTING FASTENER LOCATIONS FROM A PREVIOUS REPAIR AT RBL 27 - 33. REMOVED EXISTING REPAIR AT WEB AT RBL 27 - 33, FABRICATED A NEW T CHORD, SPLICE ANGLES, STRAP & FILLERS IAW REO G18232 REV A & ECRA 5310-06258 REV A & SRM 53-00-51 REPAIR 4 IAW ECRA. THE REPAIR BETWEEN RBL 27 - 33 HAS BEEN APPROVED UNTIL ACFT REACHES 37,500 TOTAL FLIGHT CYCLES.
Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AFT CARGO PIT STATION 1197 + 66 RBL 8 - 18 SHOWS SIGNS OF CORROSION ON UPPER J CHORD. R & R CORD IAW DWG 146T1226 SHEET 1 & SRM 51-40-02.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
MAIN CABIN FLOORBEAM STATION 1518 UPPER CAP LBL 1 SHOWS SIGNS OF CORROSION. REPAIRED FLOORBEAM AT STATION 1518 UPPER CAP IAW SRM 53-00-51 REPAIR 2.
Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AC4 CORROSION FOUND ON UPPER SURFACE STATION 1502 RBL 1 - LBL 1 SHOWS SIGNS OF CORROSION. REPAIRED CORROSION FOUND IAW SRM 53-00-51 REPAIR 4. CAT A REPAIR NO FURTHER ACTION NECESSARY.
Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
MAIN CABIN STATION 1562 LBL 54 SHOWS SIGNS OF CORROSION ON UPPER SURFACE. REMOVED DAMAGED SECTION & REPAIRED IAW SRM 53-00-51 REPAIR 1 STATION 1562 LBL 52 - LBL 90.
Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AFT CARGO FLOOR STRUCTURE STATION 1175 LBL 24 - 23 SHOWS SIGNS OF CORROSION. REMOVED & INSTALLED NEW J CHORD IAW DWG 146T1060 & SRM 51-40-02 SHEET 3.
Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FLOORBOARD FASTENER HOLES ARE CORRODED, FOUR EACH UNDER FLOORBOARD P83, RBL 11. MATERIAL REMAINING ON UPPER CHORD AT BS 933, RBL 11 EXCEEDS SRM 53-00-51 DETAIL II LIMITS. REMOVED UPPER CHORD & SEAT TRACK CROWN. FABRICATED & INSTALLED IAW DWG 145T5211 REV L BETWEEN BS 911 TO 1042 AT RBL 11 & IAW SRM 51-40-02.
Part: WEB — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
WEB UNDER STRAP CORRODED IN SEVERAL PLACES AT BS 1197+44, LBL 36 - RBL 45. J CHORD R & R IAW SRM 51-40 -02 & DWG 146T1225.
Part: SHEAR TIE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AREA AFT OF BULK CARGO COMPARTMENT LOWER BILGE FRAME SHEAR TIE IS CORRODED AT BS 1540, STRINGER 39L TO 39R. REMOVED CORRODED SHEAR TIE & FABRICATED A NEW SHEAR TIE IAW DWG 140T2102 REV C. INSTALLED PN 140T2102-607 IAW SRM 51-40-05.
Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
TRANSVERSE FLOORBEAM HAS CORROSION AT FASTENER HOLES APPROX BS 852 & RBL 76. REMOVED CORROSION & FOUND MATERIAL REMOVED EXCEEDS SRM 53-50-51 LIMITS. ORIGINAL THICKNESS IS .120, REMOVED .028, REMAINING IS .092. REMOVED DAMAGED SECTION OF UPPER CHORD. FABRICATED NEW UPPER CHORD, 2 SPLICE ANGELS & FILLER -6 & INSTALLED IAW SRM 53-00-51.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
MAIN CABIN FLOORBEAM UPPER SURFACE CORRODED AT BS 325 RBL 36 - 46. REMOVED DAMAGE. MANUFACTURED REPAIR PARTS & INSTALLED REPAIR IAW SRM 53-00-51 REPAIR 1.
Part: SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR STATION 577 RBL 44 PDU SUPPORT CHORD CORRODED UNDER NUTPLATES. REMOVED PDU SUPPORT CHORD, RECEIVED NEW CHORD 143T8236-8, LOCATED, DRILLED & DEBURRED IAW SRM 51-40-05. INSTALLED IAW DWG 143T8201 REV C & SRM 51-40-02.
Part: SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR STATION 520 RBL 44 PDU SUPPORT CHORD CORRODED UNDER NUTPLATES. REMOVED PDU SUPPORT CHORD IAW SRM 51-40-0 2. RECEIVED NEW CHORD PN 143T8236-4. LOCATED, DRILLED & DEBURRED IAW SRM 51-40-05. INSTALLED IAW DWG 143T8201 REV C & SRM 51-40-02.
Part: STRUCTURE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO COMPARTMENT FLOOR FRAME J CHORD CORRODED AT BS 566 RBL 24 & LBL 24. REPLACED J CHORD IAW SRM 51-40-02.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
MAIN CABIN FLOORBEAM UPPER SURFACE CORRODED AT BS 303 RBL 50. REMOVED DAMAGE. MANUFACTURED REPAIR PARTS & INSTALLED REPAIR IAW SRM 53-00-51 REPAIR 1.
Part: SUPPORT — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR STATION 580 RBL 30 PDU SUPPORT CHORD CORRODED UNDER NUTPLATES. REMOVED PDU SUPPORT CHORD IAW SRM 51-40-0 2. RECEIVED NEW CHORD PN 143T8236-17. LOCATED, DRILLED & DEBURRED IAW SRM 51-40-05. INSTALLED IAW DWG 143T8201 REV C & SRM 51-40-02.
Part: ANGLE — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO COMPARTMENT, CHORD ANGLE CORRODED AT BS 478 - 632 RBL 29.5. REPLACED CHORD IAW SRM 51-40-02.
Part: SKIN — DENTED (CARGO DOOR) · airframe 94,896 hrs · 14,929 cycles
BULK CARGO DOOR SKIN DENTED 2 PLACES ABOVE EXISTING DOUBLER. DENTS FOUND OUT OF SRM LIMITS. REMOVED DOUBLER & ENCOMPASSED INTO ONE REPAIR, REPAIRED IAW SRM 52-30-01 FIG 201 REPAIR 6. THIS IS A CAT B REPAIR WITH LFEC EXTERNAL INSPECTIONS TO BEGIN AT 30000 PTC & SUBSEQUENT INSPECTIONS EA 3000C THEREAFTER IAW SRM 52-30-01 FIG 201 TBL II. VERIFIED VIA ARL DOOR PN 1466301 SN 459 IS ORIGINAL DOOR, THUS FLIGHT CYCLES KNOWN TO BE SAME AS PTC OF 14929.
Part: STRAP — MECHANIC ERROR (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
SEAT TRACK STRAP HAS A DRILL START NEXT TO REPAIR FASTENER COMMON TO TRANSVERSE FLOORBEAM AT BS 873 & RBL 34. REMOVED TRANSVERSE FLOORBEAM SPLICE REPAIR, FABRICATED UPPER CHORD ANGLE & INSTALLED SPLICE REPAIR IAW SRM 53-00-51. THIS IS A CAT A PERMANENT REPAIR.
Part: STRAP — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
AFT PIT WEB UPPER STRAP IS CORRODED IN SEVERAL PLACES ON FRAME AT BS 1153 LBL 8 TO 37. REMOVED SKIN WEB AT STATION 1153, RBL 15 & DAMAGED FLOOR STRUCTURE. RECEIVED NEW J CHORD PN 146T1060-2 & INSTALLED IAW DWG 146T1204 & SRM 51- 40-05 & 51-40-02 ENTIRE LENGTH & INSTALLED SKIN WEB IAW SRM 51-40-2. THIS IS A CAT A PERMANENT REPAIR.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
BS 287 FLOORBEAM CORRODED AT LBL 12. REMOVED CORROSION & HAD MATERIAL LOSS OF .049 INCHES FROM ORIGINAL THICKNESS OF .125 INCHES, EXCEEDING SRM 53-00-51 FIG 101 DETAIL II LIMITS. REMOVED DAMAGED SECTION OF FLOORBEAM, FABRICATED -1 & -2 ANGLE, -3 STRAP & INSTALLED IAW SRM 53-00-51. PERMANENT REPAIR.
Part: STRAP — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
WEB UPPER STRAP IS CORRODED & NUTPLATES AT BS 1197 & 110, RBL 42 - 44. R & R J CHORD AT STATION 1197 & 110, RBL 42 - 44 IAW SRM 51-40-02.
Part: HEATING ELEMENT — CRACKED (OVERWING EXIT) · airframe 94,896 hrs · 14,929 cycles
RIGHT FWD OVERWING INSULATION HEATER ELEMENT CRACKED. REMOVED RT FWD OVERWING EXIT LINER. INSTALLED ON EXIT HATCH & INSTALLED ON ACFT. OPERATIONS TESTED IAW MM 21-45-61.
Part: INSULATION — BURNED (OVERWING EXIT) · airframe 94,896 hrs · 14,929 cycles
LEFT FWD OVERWING EXIT INSULATION IS BURNED AT HEATER ELEMENT. REMOVED LT FWD OVERWING EXIT LINER. INSTALLED ON EXIT HATCH & INSTALLED ON ACFT. OPERATIONS TESTED IAW MM 21-45-61.
Part: HEATING ELEMENT — CRACKED (OVERWING EXIT) · airframe 94,896 hrs · 14,929 cycles
RIGHT AFT OVERWING INSULATION HEATER ELEMENT IS CRACKED. REMOVED RT AFT OVERWING EXIT LINER. INSTALLED ON EXIT HATCH & INSTALLED ON ACFT. OPERATIONS TESTED IAW MM 21-45-61.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FLOORBEAM UPPER CORD FOUND CORRODED NEAR NUTPLATES STATION 1197 & 88 LBL 44 - 41. R & R FLOORBEAM CORD PN 146T1060-1 IAW DWG 146T1227SH1 & SRM 51-40-02. NO FURTHER ACTION NECESSARY.
Part: BEAM — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
TRANSVERSE BEAM UPPER STRAP IS CORRODED UNDER FLOORBOARD P 85 BS 880 LBL 32. REMOVED, FABRICATED & INSTALLED TRANSVERSE BEAM BS 860 - 900 LBL 33.09 IAW SRM 51-40-02 & 53-00-51 FIG 201 REPAIR 3 THIS IS A CATEGORY A REPAIR WITH NO REQUIRED INSPECTIONS OUTSIDE OF NORMAL MPD INSPECTIONS.
Part: WEB — CORRODED (FUSELAGE) · airframe 94,896 hrs · 14,929 cycles
FORWARD CARGO FLOOR WEB CORRODED ON BOTTOM SIDE STATION 610 RBL 24. CORROSION BEYOND SRM LIMITS. REMOVED, DRILLED UP NEW WEB IAW SRM 51-40-05 & DWG 143T5012 REV G.
Part: SEAL — DAMAGED (SPOILER ACTUATOR) · airframe 93,924 hrs · 14,793 cycles
HYD CTR SYS LOSS OF QTY AT GR EXTENSION. REPLACED LEAKING NR 10 SPOILER ACTUATOR FILTER HOUSING SEAL MM27-61-01. LEAK CHECKED NORMAL & C SYS REPLENISHED.
Part: WARNING BELL — FALSE ACTIVATION (COCKPIT) · airframe 93,501 hrs · 14,739 cycles
FIRE BELLS SOUNDING WITH NO FIRE INDICATION & UNABLE TO SILENCE.
2013
Part: PRESSURE SWITCH — INOPERATIVE (HYDRAULIC SYS) · airframe 92,551 hrs · 14,611 cycles
LT HYD DEMAND PUMP INOPERATIVE IN AUTO & ON MODE IAW IAHMM. REPLACED LT ENG DRIVEN PUMP LOW PRESS SW IAW AMM 29-11-17. OPERATIONS CHECKED GOOD NO LEAKS. ENG LOW PRESS SW WAS PREVENTING AUTO FUNCTION OF DEMAND PUMP.
Part: FSEU — MALFUNCTIONED (TE FLAP) · airframe 92,540 hrs · 14,607 cycles
STATUS MESSAGE FLAP SLAT ELECTRICAL. STAB POSITION CARD M838 & FLAP SLAT ELECTRICAL UNIT AT FAULT. R & R STAB MODULE & FLAP SLAT MODULE IAW 27-51-01, 27-58-01. SYS OPERATIONS CHECKED GOOD. ALSO PERFORMED TEST 30 ALL SYS PASSED.
Part: SDU — FAILED (SATCOM) · airframe 92,476 hrs · 14,598 cycles
SATCOM DOES NOT PASS INSTALL TEST IAW WORK CARD 6-2013-2C. FAILED SDU CH 5 TX & RX FAULT. REPLACED SATCOM SDU IAW MM, CHECKED OK. SOFTWARE VERIFIED CORRECT IAW IPC 31-00-00-99 & DIS 39908.
Part: LIGHT — INOPERATIVE (COCKPIT) · airframe 92,013 hrs · 14,540 cycles
CAPTAINS EXECUTE LIGHT ON FMS IS BURNED OUT.
Part: SHADE — DAMAGED (EMERGENCY EXIT) · airframe 91,652 hrs · 14,499 cycles
LT EMERGENCY EXIT WINDOW SHADE DAMAGED. STOWED IN THE OPEN POSITION. PLACED ON DF0082.
Part: CONTROL PANEL — FAULTY (COCKPIT) · airframe 91,568 hrs · 14,489 cycles
CREW REPORTS RT FLIGHT DIRECTOR INOPERATIVE. DEFERRED IAW MEL. MAINTAIN INSTRUCTION SOURCE SELECT SWITCH IN OPERATIVE POSITION FOR ALL PHASES OF FLIGHT. RT FLT DIRECTOR WAS DEFERRED BEFORE CREW REPORTED MCP PROBLEM. MODE CONTROL PANEL REPLACED. RT FLT DIRECTOR OPERATES NORMAL.
Part: AUTOPILOT SYS — MALFUNCTIONED (COCKPIT) · airframe 91,568 hrs · 14,489 cycles
MODE CONTROL PANEL FREEZES AT POWER TRANSFER & RT FLIGHT DIRECTOR DISAPPEARS. REPLACED MODE CONTROL PANEL IAW AMM & TESTED IAW AMM. FOUND ALL WORKING EXCEPT CENTER AUTO PILOT. DEFERRED CENTER AUTO PILOT IAW MEL 2210C. PERFORMED MCDP TEST FOR FCC LT, RT, BOTH FAULTED NO INFC L,R A-P CTN 1. C FCC FAULTED NO IN FC C A-P CTN 1, NO INFC C MCP A-P ENG DISC, & NO INFC C MCP A- P ARM IN. MCP TEST DISC BAR DID NOT REGISTER UPON CONT TEST.
Part: MODULE — FAULTY (THRUST REVERSER) · airframe 91,561 hrs · 14,488 cycles
R & L REV ISOLATION VALVE EICAS ILLUMINATED WITH THROTTLE QUAD LIGHT ON. REPLACED THRUST REVERSER RELAY MODULE IAW 78-36-03, OPERATIONS CHECKED GOOD.
Part: CHARGER — INOPERATIVE (MAIN BATTERY) · airframe 91,561 hrs · 14,488 cycles
MAIN BATTERY CHARGER INOPERATIVE. R & R MAIN BATTERY & BATTERY CHARGER IAW AMM.
Part: SOLENOID VALVE — FAULTY (APU) · airframe 91,419 hrs · 14,469 cycles
LOST ELECTRICAL POWER & APU FAULT EICAS MESSAGE. R&R DEOIL SOLENOID VALVE, OPERATIONS CHECKED GOOD.
Part: FAN — FAULTY (E&E BAY) · airframe 91,307 hrs · 14,457 cycles
FORWARD EQUIPMENT BAY EXHAUST FAN STATUS MESSAGE AT GATE WILL NOT ERASE. R & R FORWARD EQUIPMENT BAY EXHAUST FAN, FAN CONTROL CARD M990 & K1009 CONTROL RELAY. EQUIPMENT BAY EXHAUST FAN STATUS MESSAGE CLEARED & SYSTEM OPERATIONS NORMAL.
Part: VALVE — INOPERATIVE (RT IDG) · airframe 91,183 hrs · 14,444 cycles
RT INTEGRATED DRIVE GENERATOR VALVE STATUS MESSAGE. RT ENGINE INTEGRATED DRIVE GENERATOR VALVE INOPERATIVE. NIL TIME TO T-S. MEL COMPLIED WITH.
Part: SEAL — LEAKING (CAPTAIN'S WINDOW) · airframe 91,101 hrs · 14,433 cycles
CAPTAIN`S SIDE WINDOW HAS AN AIR LEAK IN AFT UPPER VERTICAL FRAME. FOUND AFT UPPER SEAL DAMAGED. R & R NR 2 CAPT'S OPENABLE WINDOW IAW AMM.
Part: MICROPHONE — DAMAGED · airframe 91,083 hrs · 14,430 cycles
F/O HAND MICROPHONE STRAIN RELIEF PULLED OUT OF PLUG. REPLACED HAND MIC.
Part: WARNING LIGHT — FALSE ACTIVATION (OIL FILTER) · airframe 91,028 hrs · 14,423 cycles
RIGHT OIL FILTER EICAS CAME ON MOMENTARILY 2-3 TIMES.
Part: CONNECTOR — DIRTY (NR 2 ENG) · airframe 91,004 hrs · 14,420 cycles
RT PIMU MESSAGE, FOUND A CHANNEL RESISTANCE LOW AND FLUCTUATING. FOUND DEBRIS IN CONNECTOR W5J12. CLEANED CONNECTOR AND SECURED. PERFORMED EEC STATIC CHECK IAW MM 71-00-00. OPS CK GOOD
Part: FAIRING — CRACKED (TE FLAP) · airframe 90,896 hrs · 14,406 cycles
FLAP CANOE FAIRING, 571DB HAS 1 INCH CRACK INBD SIDE. PERFORMED PERMANENT REPAIR IAW SRM 57-53-70, 1 PAGE, 103 NOTE A.
Part: CONTROLLER — FAILED (BLEED SYSTEM) · airframe 90,866 hrs · 14,402 cycles
LEFT ENGINE PRIORITY VALVE EICAS MESSAGE. R & R NR 1 ENGINE PRESSURE REGULATOR VALVE CONTROLLER IAW AMM. ACCOMPLISHED ENGINE IDLE RUN, NO BLEED FAULTS.
Part: HEAT EXCHANGER — FAILED (LT IDG) · airframe 90,701 hrs · 14,378 cycles
LEFT IDG VALVE STATUS MESSAGE. REPLACED IDG AIR-OIL HEAT EXCHANGER IAW MM. OPS TESTED IAW AMM, TESTED GOOD, IDG OPS NORMAL.
Part: SWITCH — FAILED (APU START) · airframe 90,701 hrs · 14,378 cycles
APU START SWITCH DOES NOT SPRING RETURN FROM "START" TO "ON". REPLACED APU START SWITCH AND OPS NORMAL.
Part: PRESSURE SWITCH — FAILED (BOOST PUMP) · airframe 90,698 hrs · 14,377 cycles
FUEL SYSTEM PRESSURE EICAS MESSAGE, FLT DIVERTED. REPLACED THE LEFT AFT BOOST PUMP PRESSURE SWITCH.
Part: PUMP — FAILED (LEFT) · airframe 90,635 hrs · 14,370 cycles
LEFT FWD FUEL PUMP EICAS MESSAGE. NO ASSOCIATED PRESSURE LIGHT IN LT FWD FUEL PUMP SWITCH. FOUND P6 CIRCUIT BREAKER FWD BOOST PUMP OPEN. REPLACED LT FWD BOOST PUMP. LEAK AND OPS CHECKED GOOD.
Part: OUTFLOW VALVE — MALFUNCTIONED (CABIN PRESSURE) · airframe 90,385 hrs · 14,336 cycles
RECEIVED A CABIN ALTITUDE WARNING IN AUTO 1 - CABIN ALTITUDE REACHED 10,000 FT, MANUAL CONTROL AND AUTO 1 OK, NOW CONTROL OK AND AUTO 1 OK. NOW SHOWING GRADUAL CLIMB IN AUTO 1 EVEN THOUGH DIFFERENTIAL PRESSURE IS LESS THAN 8 PSI. CREW SELECTED MANUAL AND RECOVERED CABIN PSI. ACCOMPLISHED LM CALLOUTS ON PTT SEQ 3852009, 3852008 AND 3852001, OPS CHECKED GOOD.
Part: AUDIO PANEL — WEAK (COCKPIT) · airframe 90,133 hrs · 14,303 cycles
FIRST OFFICER`S AUDIO PANEL VOLUME WEAK ALL CHANNELS SPEAKER VOLUME OK HEADSET WEAK. REPLACED MINITEL.
Part: CIRCUIT BREAKER — TRIPPED · airframe 90,064 hrs · 14,295 cycles
CREW REPORTED CIRCUIT BREAKER G17 ON P11 TRIPPED SHORTLY AFTER TAKEOFF. G17 FOR 1R CSEU AC PWR SUPPLY. RESET NOT ATTEMPTED DUE TO POWER SUPPLY 2R POWERING THE CSEU. RERACK CSEU POWER SUPPLY AND CHECK PINS ALL OK RESET CIRCUIT BREAKER. CIRCUIT BREAKER STAYED IN, NO FAULT BALLS, TEST POWER SUPPLY AS PER MM, ALL OK.
Part: ACTUATOR — LEAKING (RUDDER) · airframe 89,890 hrs · 14,277 cycles
RUNNING HYD LEAKAGE FROM VERTICAL STABILIZER. INDENTIFIED LEAKING COMING FROM RUDDER RATIO ACTUATOR (RRCA) ROD END. RRCA NEED REPLACEMENT REF AMM 27-21-15.
Part: CONTACT — DIRTY (EXTINGUISHER) · airframe 89,823 hrs · 14,270 cycles
AFT CARGO FIRE EXTINGUISHER ARM LIGHT DOES NOT ILLUMINATE DURING FIRE TEST. CLEANED AND RESEATED CONTACTS ON ARM LIGHT. OPS TESTED NORMAL.
Part: HOOK AND LOOP — LOOSE (LIFE VEST POUCH) · airframe 89,813 hrs · 14,269 cycles
LIFE VEST POUCH ON CAPT SEAT IS LOOSE. REPLACED VELCRO ALL OPS OK.
Part: PUMP — FAILED (FUEL SYSTEM) · airframe 89,737 hrs · 14,256 cycles
FUEL CONFIGURATION LIGHT ON DURING CRUISE. ALL PUMPS ON. NO LIGHTS. PERFORMED FUEL PROCESSOR BITE FOUND FAULTS RM DENS SENSOR FAILURE A01, AND RM DENS SENSOR OPEN AT SPAR A01. VERIFIED MFQ OF RT AND LT TANKS TO BE WITHIN LIMITS VIA STICK READINGS AND PER FUELING MANUAL 6-4-2,31. REPLACED DENSITOMETER FOR FAULT HISTORY ONLY , FUEL CONFIG LIGHT SHOULD BE CORRELATED. FUEL PUMP REPLACED.
Part: BLOCKER DOOR — DAMAGED (THRUST REVERSER) · airframe 89,653 hrs · 14,245 cycles
NR 1 ENGINE HAS A DAMAGED BLOCKER DOOR ON THE INNER THRUST REVERSER HALF AT THE 4.30 TO 5 O'CLOCK POSITION. REMOVED BLOCKER DOOR AND DRAG LINK PER CDL AND MM78-31-14 AND 15. REPLACED BLOCKER DOOR.
Part: LINER — DENTED (THRUST REVERSER) · airframe 89,645 hrs · 14,244 cycles
NR 1 ENGINE INBOARD THRUST REVERSER HALF HAS THREE DENTS IN THE ACOUSTIC LINER IN THE INNER C DUCT. REPAIRED IAW SRM 54-00-01 REPAIR 1 AND 2.
Part: CONTROL UNIT — FAILED (HYD PUMP) · airframe 89,313 hrs · 14,199 cycles
ACFT RETURNED TO BLOCKS WITH C1 ELECTRIC HYDRAULIC PUMP INOPERATIVE. NO HYD PRESSURE ON EICAS PAGE. FOUND PUMP TO OPERATE NORMAL FOR ABOUT 10 MINUTES AND THEN SHUTOFF UNCOMMANDED WITH NO UNUSUAL MESSAGES. REPLACED ELCU PER MM 29-11-14. RAN PUMP FOR 30 MINUTES LOADING PUMP WITH FLT CONTROLS AND OPERATION WAS NORMAL.
Part: PROBE — FAILED (LT ENGINE) · airframe 88,981 hrs · 14,154 cycles
LT ENGINE EEC MODE ILLUMINATED, FLT DIVERTED. REPLACED PT2 TT2 PROBE REF MM 73-21-03 ACCOMPLISHED PT2 SYSTEM LEAK TEST NO14 REF MM 71-0 0-00 AND EEC IDLE TEST NO6 REF MM 71-00-00 ALL CHECKED OK.
Part: WIRE HARNESS — CHAFED (LT ENGINE) · airframe 88,979 hrs · 14,153 cycles
CREW REPORTED WHEN LEFT ENGINE START SELECTED, CBS D19 (LT ENG START CONT) AND D28 (STBY ENG IND) ON P11. MAINTENANCE FOUND BENT PIN AT CONNECTOR D7982P ON P61 AND DAMAGED WIRES ON START VALVE HARNESS REF WDM80-11-11. FOUND WIRE BUNDLE TO STARTER VALVE CHAFED. ABOUT 2' BEFORE VALVE. PERFORMED TEMP REPAIR IAW SWPM 20-10-13. OPS TESTED OK.
Part: START VALVE — FAULTY (LT ENGINE) · airframe 88,972 hrs · 14,152 cycles
WHEN GROUND SELECTED FOR LT ENGINE START, CIRCUIT BREAKER D28 AND D19 TRIPPED. REPLACED LEFT ENGINE START VALVE.
Part: ANTI-ICE VALVE — DAMAGED (LT ENGINE) · airframe 88,763 hrs · 14,124 cycles
HMG HAS BEEN DEF IN COMPLIANCE WITH MEL CARD. REPLACED NUMBER 1 ENGINE COWL TAI VALVE REF AMM, NO HELP. ENG ANTI- ICE VALVE REPAIRED AND HMG SYSTEM HAS BEEN RESTORED PER MEL CARD. RAN CHECK & HMG CHECKED NORMAL. PERFORMED LEFT ENGINE ANTI-ICE VALVE TEST AND ALL INDICATIONS NORMAL. LEAK CHECKS GOOD. ALL VALVE INDICATIONS NORMAL DURING TEST.
Part: HYDRAULIC LINE — LEAKING (RT WING) · airframe 88,722 hrs · 14,119 cycles
RIGHT HYDRAULIC SYSTEM QTY READS .81 ON ARRIVAL LHR. HYDRAULIC LINE LEAKING IN AREA BELOW RIGHT INBD SPOILER ACTUATOR. FOUND HYDRAULIC LINE WITH IMPACT DAMAGE. SEE IPC REF 29-11-77-005 ITEM 560. REPLACEMENT TUBE SECTION IAW AMM 20-10-09 REV 75 & GPM 1-0-13-006. TUBE SECTION INSTALLED BMS 7-185 - 21-6-9 CRES STEEL. SWAGE FITTINGS INSTALLED AT 2 LOCATIONS PER GPM 1-0-13-20. LEAK CHECKS ACCOMPLISHED, ALL OPS NOW NORMAL.
2012
Part: HINGE — BROKEN (LT WING) · airframe 88,481 hrs · 14,083 cycles
LEFT WING THERMAL ANTI-ICING DUCT SEAL DOOR ASSY AFT HINGE BROKEN AND AFT OUTBD. CORNER OF PANEL SHEET METAL TORN. REMOVED DAMAGED DOOR ASSEMBLY AND HARDWARE AND PLACED IN BULK PIT. REMOVED DAMAGED ERODED EDGE STRIP AND APPLIED LAY-UP REPAIR PER SRM 57-41-01, RPR 2. REPLACED HINGES AND RE-INSTALLED TAI DOOR PER MM. DOOR ADJUSTMENT CHECKS GOOD PER MM. RESTORED ACFT TO NORMAL CONDITION.
Part: SKIN — CRACKED (LE SLAT) · airframe 88,481 hrs · 14,083 cycles
LEFT WING NR 5 LEADING EDGE SLAT HAS A CRACK IN THE LOWER SURFACE OF THE SLAT SKIN AT THE TAB INBOARD OF THE ANTI ICING DOOR ASSEMBLY. CRACK STARTS AT AFT EDGE OF TAB AND EXTENDS 1 INCH TO RIVET. COMPLIED WITH SRM 57-43-01 PAGE 104 ITEM P. ALL ITEMS IN AREA ARE SECURED. REMOVED DAMAGED PLIES AND BOND NEW REPAIRS 2 IAW SRM APPLIED CONDUCTIVE COAT MM RESTORED FINISH.
Part: PRESSURE SENSOR — DEFECTIVE (COCKPIT DOOR) · airframe 88,465 hrs · 14,080 cycles
FLT DECK DOOR CKT BREAK POPPED. TROUBLESHOT SYSTEM FOUND PRESSURE SENSOR BAD. INSTALLED ROBBED SENSOR. GROUND FUNCTIONAL TEST NORMAL IAW WD 52-51-11. NEW SENSOR ON AOG L4650 RESET CB NORMAL.
Part: COMPUTER — FAULTY (AUTOTHROTTLE SYS) · airframe 88,220 hrs · 14,046 cycles
LT ENG HYD LEAK, FLIGHT DIVERTED. CREW REPORTS AUTOTHROTTLE DISCONNECT. WOULD NOT RESET. REPLACED THRUST MANAGEMENT COMPUTER PER MM. HYDRAULIC L ENG PUMP SUPPLY CB POPPED. LOCATION OVHD PANEL D29. LEFT ENG HYD SHUT-OFF VALVE IS LEAKING AT UPPER MATING FLANGE. INSTALLED NEW O-RINGS ON UPPER AND LOWER MATING FLANGES, LEAK CHECK OK. REPLACED LEFT ENG HYD SHUTOFF VALVE PER AMM, OPS CHECK GOOD.
Part: TRANSMITTER — FAULTY (LT AILERON) · airframe 87,900 hrs · 13,993 cycles
INBOARD AILERONS DO NOT EXTEND SYMMETRICALLY WHEN FLAPS ARE LOWERED; RT SIDE DROPS LOWER. FOLLOWED FIM 27-18-00 FIG 106 FOR INDICATOR FAILS TO RETURN TO ZERO WITH CONTROL WHEEL ZERO. FOLLOW "NO" ON DIAGRAM AND NEXT STEP STATES TO EXAMINE AILERON CABLE SYSTEM. REMOVED AND REPLACED LEFT INBOARD AILERON POSITION TRANSMITTER REF MM27-18-10 AND MM 27-18-00 RIG PINS AS1 AND AS2 INSTALLED FOR RIGGING PINS REMOVED AFTER COMPLETION OF TRANSMITTER REPLACEMENT.
Part: TRANSMITTER — FAULTY (TE FLAP) · airframe 87,738 hrs · 13,972 cycles
FLAP SLAT ELEC STATUS MSG. DUE TO REPEAT FLAP SLAT ELEC STATUS EICAS MESSAGES AND NOTHING FOUND WHEN BITING THE FSEU, INSTALL A -63 FSEU PCN 481-9266 PER MM. CREATED A CF ITEM STATING THAT THE -63 IS INSTALLED AND TO BE REMOVED AT A LATER DATE. REPLACED FSEU BOX. FOUND NR 8 FLAP POS TRANSMITTER OUT OF RANGE, PER MM. READING 226.45 SHOULD READ APPROX 47.57. REPLACED NR 8 FLAP POS TRANSMITTER TARGET 47.48. NOW WITHIN LIMITS PER MM. OPS CHECK FLAP SEVERAL TIMES, OPS NORMAL.
Part: INVERTER — FAULTY (NR 1) · airframe 87,664 hrs · 13,963 cycles
STANDBY INVERTER STATUS MESSAGE . REPLACED STANDBY INVERTER IAW MM.
Part: WIRE — CHAFED (VACUUM BLOWER) · airframe 87,444 hrs · 13,937 cycles
AFT VACUUM BLOWER (LAV SYS 1) CIRCUIT BREAKER POPPED. TROUBLESHOT AS PER WD 38-32-11. FOUND NO POWER AT PINS 2 AND 3 ON D1266, HAVE 115V AC AT PINS 22 2 0 24 ON D6314 NEED TO CHECK FROM D1266 BACK. NO FURTHER TIME DUE TO AC MOVEMENT BLOWER SYSTEM DEACTIVATED AS PER MEL CP PULLED. FOUND CHAFED WIRES W1354 -017-12 AND W1354-001-16 REF WDM 38-32-11 AND 21-26-11. REPAIRED WIRES WITH A SEALED SPLICE AT STA. 1550 FWD OF CABIN PRESSURE OUTFLOW VALVE (V15) PER SWPM 20-10-13 AND 20-30-12. OPS CHECK GOOD.
Part: DUCT — DAMAGED (APU COOLING) · airframe 87,178 hrs · 13,900 cycles
APU COOLING AIR DUCT DAMAGED. REPLACED COOLING AIR DISCHARGE DUCT AND SECURED WITH CLAMPS PER AMM.
Part: PRESSURE SWITCH — FAILED (APU OIL) · airframe 87,163 hrs · 13,898 cycles
LOW OIL PRESSURE SWITCH FAULTED. REPLACED LOW OIL PRESSURE SWITCH RAN APU. APU AUTO SHUTDOWN AFTER 90 SEC.
Part: CONTROL UNIT — FAULTY (APU) · airframe 87,163 hrs · 13,898 cycles
APU AUTO SHUTDOWN AT THE GATE. REPLACED CONTROL UNIT PER MM. OPERATED APU PER JRH 2-6-15 WITH PNEUMATIC AND ELEC LOAD APPLIED. RUNS NORMAL.
Part: FILTER — FAULTY (APU OIL) · airframe 87,148 hrs · 13,896 cycles
FOUND APU GENERATOR LUBE SYSTEM FILTER DIFFERENTIAL PRESS IND POPPED. REPLACED APU GENERATOR LUBE SYSTEM FILTER AND RESET DIFFERENTIAL PRESSURE INDICATOR.
Part: PRESSURE SWITCH — FAILED (APU OIL) · airframe 87,148 hrs · 13,896 cycles
APU AUTO SHUTDOWN. APUC BITE TEST SHOWED LOP. REPLACED LOW OIL PSI SWITCH. REPLACED APU DEOIL SOLENOID AND FLOW SENSING MODULE-NO HELP. FOUND DIFFERENTIAL PRESS IND POPPED FOR GENERATOR LUBE FILTER.
Part: BRAKE — FIRE (LT MLG) · airframe 87,025 hrs · 13,881 cycles
LEFT MAIN GEAR AFT INBD BRAKE TEMP WENT TO 7. GROUND CREW NOTED FLAME AND DISCHARGED POWDER TYPE FIRE EXTINGUISHER. TIRE FUSE DID NOT RELEASE. CDG FIRE DEPT WAS CALLED AND SPRAYED WATER ON LEFT MAIN BRAKES. WHEEL AND BRAKE REPLACED LEFT MAIN GEAR AFT INBD POSITION.
Part: ACCESS PANEL — OUT OF ADJUST (LT WING) · airframe 86,940 hrs · 13,869 cycles
LEFT WING FUELING PANEL WILL NOT STAY OPEN. SUPPLEMENTAL DATA, FUELING PANEL DOOR HOLD OPEN EYELET ADJUSTED TO SIT CORRECTLY IN RETAINING HOLE. NOW OPERATES NORMALLY.
Part: BRAKE — FIRE (MLG) · airframe 86,866 hrs · 13,859 cycles
HOT BRAKES, RAMP SAW FLAMES COMING FROM BRAKE. ACCOMPLISHED INSPECTION MM.
Part: VALVE — MALFUNCTIONED (CABIN TEMP) · airframe 86,220 hrs · 13,778 cycles
UNABLE TO CONTROL CABIN TEMP. CYCLED CB C33 PER TOMC AND REGAINED CAB TEMP CONTROL. FOUND MID TRIM MODULATING VALVES IN OPEN POSITION. AS PER DF0690 CLOSED AUX MID AND MID MODULATING VALVES.
Part: PANEL — DAMAGED (LT WING) · airframe 85,619 hrs · 13,700 cycles
LEFT WING FIXED T/E UPPER OTBD PANEL HAS DAMAGE. REF IPC 57-51-65-002 REMOVED AND ROUTED TO SHOP 273 FOR DELAM REPAIR ON R62260.
Part: PANEL — DAMAGED (LT WING) · airframe 85,607 hrs · 13,698 cycles
LT WING PANEL ISSUE, FLIGHT DIVERTED. THE L/E IS UP INTO THE AIRSTREAM APPROX 2-3 INCHES. NO CONTROL OR VIBRATION PROBLEMS. REMOVED PANEL. REPAIRED IAW EC-RA NR 5700-03044
Part: CABLE — SHORTED (CABIN) · airframe 85,484 hrs · 13,683 cycles
P62 PIGTAIL SPARKS WHEN DISCONNECTED. COLLARED CB. REPLACED SHORTED PIGTAIL CABLE AND RESET C-B.
Part: CONTROL UNIT — FAULTY (FLAP/SLAT) · airframe 84,874 hrs · 13,603 cycles
FLAP-SLAT MSG. TRBLSTG PER FIM. NEW FSEU, NO HELP. FAULTING M548 OTBD SLAT POS XDCR. ON AOG, E5555 ETA 0450. DMM 0240. REPLACED FSCU PER MM. SYSTEM OPERATED NORMAL. NO EICAS OR STATUS MSG. PRESENT.
Part: IGNITER — FAILED (NR 2 ENGINE) · airframe 84,636 hrs · 13,574 cycles
NO EGT RISE ON RT ENG WITH NR 2 IGNITION START OK ON BOTH IGNITORS. REPLACED NR 2 IGNITER PLUG IAW MM, ENGINE STARTED OK PER JRH 2-6-1.
Part: WIRE — BROKEN (FCC) · airframe 84,626 hrs · 13,573 cycles
CENTER FCC FAILS INTERFACE TEST 04. FOUND WIRE W011-770-22 BROKEN AT CONNECTOR D479. REPINNED WIRE REF BOEING STANDARD PRACTICES MANUAL 20-10-13. CTR FCC TEST NORMAL. ACP CAT III TEST PER MM, TEST PASSED. AIRCRAFT RETURNED TO CAT III STATUS
2011
Part: SELECTOR KNOB — BROKEN (HEADING) · airframe 84,606 hrs · 13,571 cycles
HEADING SELECT KNOB BROKEN BUT USEABLE. REPLACED MCP PER MM.
Part: PANEL — LOOSE (RT WING) · airframe 84,492 hrs · 13,555 cycles
FOUND DURING WALK AROUND THE RT ANTI-ICE DUCT FAIRING PANEL JUST OUTSIDE OF THE ENGINE REAR PART HANGING DOWN. REMOVED PER CDL 57EE. DOOR ASSY IS LOST. REPLACED PANEL.
Part: CONTROLLER — FAULTY (CABIN) · airframe 84,311 hrs · 13,532 cycles
AFT CABIN TEMP EICAS MESSAGE WITH INOP LIGHT ON. RESET ZONE TEMP CONTROLLER - NO HELP. CW MEL. REPLACED ZONE TEMP CONTROLLER PER MM, OPS CHECK GOOD. NO EICAS MESSAGES OR FAULTS.
Part: WIRE — DAMAGED (GENERATOR SYS) · airframe 84,062 hrs · 13,499 cycles
CREW ABORTED TAKEOFF AT APPROXIMATELY 80 KNOT DUE TO NR 1 GEN DRIVE LIGHT AND ASSOCIATED EICAS MSG. ACCOMPLISH HIGH ENERGY STOP CHECK PER MM 05-51-14 201. ITEM ROLLED FORWARD. ACP'D INSP PER AMM. NO DEFECTS NOTED. DUE TO RECENT REPORTS OF THE NR 1 ENG IDG DRIVE LIGHT COMING ON DURING TO ROLL, AFTER REPAIR TO AFFECTED IDG WIRING. RUN ENGINE AT HIGH POWER FOR A MINIMUM OF 10 MINUTES TO VERIFY POSITIVE FIX. ACCOMPLISHED HIGH PWR RUN NR 1 ENG PER LM CALLOUT. VOLTS AN FREQS WITHIN LIMITS PER JRH 2-6- 5. TEMPS NORMAL, NO FLUCTUATIONS OR ABNORMALITIES NOTED. WITH NR 1 IDG CARRYING ALL LOADS, ALL OPS NORMAL AS ABOVE.
Part: PRESSURE SWITCH — FAULTY (FUEL PUMP) · airframe 83,409 hrs · 13,409 cycles
LEFT HYD DEMAND PUMP FAILED TO OPERATE IN AUTO WITH ENGINE OFF. WORKS OK IN ON POSITION. -RDF-T :RPL S27 ELEC HYD PUMP L CONTROL PRESSURE SWITCH, NO HELP. REPLACED RELAYS K130, K134, & K131 NO HELP. REPLACED L DEMAND PUMP SWITCH ASSY S5, NO HELP. CHECKED WIRING BETWEEN RELAYS K130, K131 AND S25, S26 AND S27 OK REF WDM 29-11-12. REPLACE ENG PUMP LT PRESS SWITCH S26. OPS CHECK NORMAL.
Part: TRANSCEIVER — WEAK (HF COMM) · airframe 83,409 hrs · 13,409 cycles
HF TRANSMISSION AND RECEPTION ARE INOP, WEAK,GARBLED INTERMITTENT, ETC AT ALL CREW STNS. (1 = L HF, 2 = R HF). MAINT TEXT: LEFT HF INOP PER CREW. NO TIME TO TROUBLESHOOT. COMPLIED WITH MEL. REPLACED LEFT HF TRANSCEIVER PER AMM, OPS CHECKS GOOD.
Part: CONTROL VALVE — FAULTY (CARGO HEAT) · airframe 83,153 hrs · 13,374 cycles
AFT CARGO OVERHEAT LIGHT ON. REPLACED AFT CARGO HEAT CONTROL VALVE PER MM, OPS CHECKED NORMAL.
Part: FAIRING — MISSING (FUSELAGE) · airframe 82,803 hrs · 13,321 cycles
DURING RAMP CHECK FOUND PANEL MISSING ON AFT TOP OF RIGHT LANDING GEAR BODY DOOR AREA. ACCOMPLISH REPAIRS PER EVA 81169. RT WING MLG SIDE STRUT SWIVEL FAIRING ASSEMBLY TEMPORARY FAIRING INSTALLED AS PER EVA-8 1169. VERIFICATION REQUIRED BEFORE EACH FLIGHT FOR SECURITY OR DEFORMATION ALSO RIGHT MAIN LANDING GEAR SHOCK STRUT DOOR VERIFICATION RQRS EVERY FLT FOR DAMAGE. THIS FAIRING IS LOCATED UNDER THE WING JUST FORWARD OF THE RIGHT MLG SIDE STRUT SWIVEL.
Part: AILERON SYS — BINDING (LEFT) · airframe 82,728 hrs · 13,308 cycles
CREW REPORTS DURING THE FLIGHT CONTROL CHECK BOTH CAPT AND F/O FELT BINDING IN THE LEFT AND RIGHT AILERON CONTROL CHECK. AILERON CONTROL BINDING. MM INSPECTED CABLES AND BEARINGS PER MM. LUBED LEFT FEEL AND CTR MECH AND LEFT OUTBOARD AILERON PER MM. DISCONNECTED AND RECONNECTED RODS TO L,R,C LCCA. DISCONNECTED AND RECONNECTED BUS BAR BETWEEN CAPTS AND F/O COLUMN. DISC AND REFITTED SPOILER RVDT & FL FRCE TRNS. WHEN CAPTAINS COLUMM GETS TO 6.5 UNITS BEARING IN COLUMN OR DRUM HAS FLAT SPOT WITHIN LIMITS PER MM. REF WHEEL FORCE CHECK PER MM. TORQUE IS BETWEEN 65-104 POUNDS INCHES AND ACTUAL READING NEVER EXCEEDED 80 LBS INCHES.
Part: FITTING — MISSING (CABIN) · airframe 82,705 hrs · 13,304 cycles
STRANGE NOISE AROUND ROW 19A. SOUNDS LIKE OBJECT FLAPPING IN WIND STREAM CLOSE TO FUSELAGE. FOUND LEFT AFT OVERWING DOOR STEP CHORD DISCONNECTED, REPLACED MISSING CIRCLIP AND SECURED CHORD TO STEP, ALL CHECKS NORMAL.
Part: WIRE — BROKEN (AUTOPILOT) · airframe 82,176 hrs · 13,219 cycles
MCP FAULT. FOUND AUTOPILOT ANNUNCIATOR LIGHT L19 FAULTING. TRIED GOOD UNIT FCC L & R PASSED TEST 1. C FCC FAULTING NO INFC FCC C MCP A-P EN G DISC AND NO INFC FCC C MCP A-P ARM IN. PER FIM 28 V DC PRESENT AT PINS 7 ALL CONNECTORS. ACCOMPLISHED WIRING CHECKS PER WDM. FOUND BROKEN WIRE AT MCP CONNECTOR D479 PIN 30 WIRE W011-770-22. REPLACED THE CONTACT PIN AND ACCOMPLISHED CAT III GROUND CHECK PER MM, SYS CHECKED OK. REPLACED MODE CONTROL PANEL & C FCC COMPUTER REF MM.
Part: UNKNOWN — ODOR (CABIN) · airframe 81,867 hrs · 13,176 cycles
CREW REPORTS BURNING RUBBER SMELL AT ROWS 31 TO 33. CALL LIGHT ON AT SEAT 33C WITHOUT CALL BUTTON, SEAT VIDEO 33C WENT BLANK AND SMELL DISSIPATED. CREW REPORTED CALL LIGHT WAS ABLE TO BE RESET. CHECKED VICINITY OF ROWS 31C THRU 33C ALL PCU AND VIDEO FUNCTIONS NORMAL. NO BURNING ODOR NOTICED.
Part: PUMP — DEFECTIVE (NR 1 ENGINE) · airframe 81,638 hrs · 13,142 cycles
NR 1 ENG FUEL PUMP NEEDS TO BE OP AND LEAK CHECKED. FUEL PUMP CHANGED BY AMT. PERFORM IDLE RUN TO OPS CHK FUEL FILTER CONNECTOR NR 1 ENGINE. ACP'D FIVE MINUTE IDLE NR 1 ENGINE, OPS CHK OKAY. NO MESSAGES.
Part: CONNECTOR — LOOSE (NR 1 ENGINE) · airframe 81,638 hrs · 13,142 cycles
NR 1 ENG MAIN FUEL FILTER SENSOR CANNON PLUG IS LOOSE. REPLACED CONNECTOR D10996.
Part: FLOOR PANEL — CRACKED (ROW 20 RT) · airframe 81,587 hrs · 13,133 cycles
AROUND ROW 20 RT FLOOR SOFT HAS SLIGHT INDENTATION. FLOOR PANEL HAS 18 IN CRACK DOWN CENTER. ACCOMPLISHED INTERIM REPAIR IAW EVA 80757.
Part: PRESSURE SENSOR — FAILED (FUEL SYSTEM) · airframe 81,476 hrs · 13,116 cycles
L FUEL OVERRIDE PUMP CIRCUIT BREAKER IS OUT. MEL COMPLIANT. REPLACED LEFT OVERRIDE PUMP PER AMM. NO PUMP PRESSURE. CHECKED PRESSURE SWITCH, OVERRIDE PUMP FOUND FAILED. REPLACED PCN AS PER MM. OP'S NORMAL NOW.
Part: RELAY — FAULTY (HYDRAULIC SYS) · airframe 81,315 hrs · 13,092 cycles
LEFT HYD ELEC DEMAND PUMP IN AUTO CAUSES PRESS AND SYS PRESS LTS TO ILLUMINATE. WORKS IN ON. DEFERRED LEFT HYD ELEC DEM AND PUMP AUTO FUNCTION IAW MEL. REPLACED K130 RELAY. LEFT HYD DEMAND PUMP OPERATES NORMAL IN AUTO.
Part: HOLDER — DEFECTIVE (CABIN) · airframe 81,293 hrs · 13,088 cycles
RT OVERWING SLIDE AFT EMERGENCY LIGHT INOPERATIVE. REPLACED LAMPHOLDER ASSY PER MM, OP CHECKS NORMAL.
Part: CONNECTOR — UNSECURE (CABIN) · airframe 81,293 hrs · 13,088 cycles
FWD GALLEY CROSSAISLE EEL LIGHT STRIP INOP. SECURED POWER FEEDER CONNECTOR, OPS CHECKED OK.
Part: ACTUATOR — LEAKING (RUDDER) · airframe 81,048 hrs · 13,051 cycles
HYD LEAK COMING FROM VERTICAL STABILIZER MID AREA. SWING RUDDER BACK AND FORTH, WITH RIGHT HYD SYSTEM,LEAK INTENSIFED. REPLACED RT RUDDER PCA REF MM.
Part: HEAT SHIELD — BROKEN (NR 2 ENGINE) · airframe 81,030 hrs · 13,046 cycles
REPLACED THE OIL TANK HEATSHIELD ON NR 2 ENGINE DUE TO LOWER SECTION BROKEN AND SEPARATING, WHICH HAS DAMAGED THE WIRE BUNDLE BELOW. REPLACED NR 2 OIL TANK HEAT SHIELD IAW MM.
Part: IDG — FAULTY (NR 2) · airframe 81,028 hrs · 13,045 cycles
RIGHT IDG DRIVE LIGHT CAME ON STEADY DURING CLIMB AT APPROX 10,000 TO 12,000 FT. WHEN THE DRIVE LIGHT CAME ON IT WAS ACCOMPANIED BY A VIBRATION. WHEN THE IDG WAS DISCONNECTED THE VIBRATION ENDED. REPLACED OVHD PUSH BUTTON SWITCH & RT IDG.
Part: HEAT EXCHANGER — FAULTY (IDG OIL) · airframe 81,027 hrs · 13,044 cycles
DUE TO HISTORY OF RT IDG DRIVE LIGHT ON IN FLIGHT AND POSSIBLE FUEL CONTAMINATION AT TERMINATION OF FLT REPLACE IDG AIR-OIL HEAT EXCHANGER AND VALVE. (HEAT EXCHANGER AND VALVE SHOULD BE REPLACED AS AN ASSY). AIR OIL COOLER REPLACED IAW MM.
Part: IDG — OVERSERVICED (RT GENERATOR) · airframe 81,026 hrs · 13,043 cycles
RT IDG DRIVE LIGHT, RTFL. CAME ON RT AFTER TAKEOFF. CREW REDUCED POWER AT 10,000 AND THE DRIVE LIGHT WENT OUT. CREW STARTED CLIMB & AT 12,000 FT, DRIVE LIGHT CAME BACK ON AND WOULD NOT GOT OUT. CREW DISCONNECTED IDG. CHECKED OIL LEVEL IN RIGHT IDG AFTER LANDING AND NOTIFIED SAMC 767 MAINT. CONTROLLER WITH FINDINGS. FOUND OVERFILLED BY 1 QUART.
Part: IDG — OVERSERVICED (RT GENERATOR) · airframe 81,025 hrs · 13,042 cycles
RT ENG IDG EICAS, RTFL. RIGHT IDG DRIVE LIGHT ILLUMINATED ON CLIMB. CREW REDUCED THE POWER ON THE RIGHT ENGINE AND THE DRIVE LIGHT WENT OUT. AT THIS TIME THE IDG IS NOT DISCONNECTED. FOUND IDG OVERSERVICED. REPLACED NR 2 ENG IDG. REPLACED NR 2 ENG IDG DRIVE OIL SEAL. RAN ENGINE AT HIGH POWER. SYS CHECKS GOOD. NO OIL LEAKS NOTED.
Part: IDG — FAULTY (RIGHT) · airframe 81,025 hrs · 13,041 cycles
RT GEN DRIVE LIGHT ON AND CREW DISCONNECTED GEN. FOUND RT IDG OVER SERVICE DRAINED 1.5 QTS. REPLACED RT GCU IAW MM. RAN BOTH ENGS FOR 5 MIN IAW JRH, ALL INDICATION ARE NORMAL, AFTER RUN CHECK IDG OIL SERVICE, FOUND NORMAL.
Part: IDG — FAULTY (RT GENERATOR) · airframe 81,016 hrs · 13,040 cycles
CREW REPORTS RT GENAERATOR DRIVE LIGHT ILLUMINATED. CREW DISCONNECTED RT GENERATOR. RT ENGINE IDG REPLACED. IDLE RUN ACCOMPLISHED BY CREW, GENERATOR OPS NORMAL. IDG SERVICED WITH 2197 OIL.
Part: PROBE — LEAKING (PITOT STATIC) · airframe 80,974 hrs · 13,034 cycles
LOUD SQUEAL FROM BEHIND CAPT INST PANEL - REPEAT. TROUBLESHOT AND FOUND LT UPPER AND LOWER PITOT PROBE LEAKING, LT TAT PROBE AND RADOME HINGE ATTACHMENT BOLTS LEAKING. SEALED AS REQUIRED. PERFORMED LEAK CHECK, NO LEAKS NOTED.
Part: BONDING JUMPER — BROKEN (BLEED AIR SYS) · airframe 80,699 hrs · 12,993 cycles
NR 1 ENG HPSOV BONDING JUMPER BROKEN AT LUG. REPLACED BROKEN BONDING JUMPER ON HPSOV AND SAME ON HP-IPSOV.
Part: VALVE — INOPERATIVE (HYD PUMP) · airframe 80,699 hrs · 12,993 cycles
ON SHORT FINAL HAD C HYD DEM PUMP EICAS AND PUMP PRESSURE LIGHT 2 TIMES FOR ABOUT 10 SECONDS EACH. CENTER ADP PUMP HAS BEEN RENDERED INOP PER MEL. FOUND HPSOV BITE FAILS. REPLACED NR 1 HPSOV IAW MM.
2010
Part: CONNECTOR — FAILED (WINDOW HEAT) · airframe 80,398 hrs · 12,946 cycles
WINDOW MESSAGE DISPLAYED ON EICAS. INOP LGT ILLUM. INOP LGT EXTINGUISHED WHEN SW WAS RECYCLED TO OFF THEN ON. POSN 4 (1=L FWD, 2=L SIDE,3=R FWD,4=R SIDE) FRM 30 41 01. CREW COMMENTS: LT SIDE WINDOW HEAT FAILED 3X - RESET EACH TIME FOR SEVERAL HOURS. REPLACED WHC M192 IAW MM, CKD WINDOW CONNECTORS, CKD BENCH PLUG WHC, OPS CHECKED OK.
Part: ADC — FAULTY (LEFT) · airframe 80,349 hrs · 12,938 cycles
CAPTAIN ALT CONSTANTLY MOVES UP AND DOWN 60' AT CRUISE. ALSO TEMPORARILY WENT UP IN DESCENT. ALL FLIGHT CONTROLS FELT UNUSUALLY HEAVY ON FINAL AND LANDING. IAW CREW HEAVY FORCES WERE NOTICED ON AIL AND ELEV. LT ADC REPLACED. ACP BITE CHK OF ALL CSEU UNITS. ACP CK OF MCDP NO LAST FLT FAULTS. ACP LM6996 ALL CONTROL MOVEMENTS NORMAL & VISUAL CHECK OF VISIBLE CABLES & QUADRANTS NORMAL, ALSO CKD DRAIN TUBES. CONFERRED WITH LM ON ALL CKS. REPLACED CAPT'S ALTIMETER MM. TESTED NORMAL.
Part: AMPLIFIER — INOPERATIVE (SATCOMM) · airframe 80,143 hrs · 12,910 cycles
SATCOM HI GAIN INOPERATIVE. AMPLIFIER FOUND DEFECTIVE. REPLACED HIGH POWER AMPLIFIER.
Part: ACTUATOR — LEAKING (AILERONS) · airframe 79,934 hrs · 12,880 cycles
LT WING AFT OF PYLON SAIL TAIL AREA HAS EVIDENCE OF HYD LEAK. LEAK IS AT LT INBD AILERON INBD ACTUATOR ON ACT ROD SEAL. LEAK IS MEASURED AT 4 DROPS PER MIN. COMPLETED ACTUATOR REPLACEMENT.
Part: ACTUATOR — BYPASSING (SPOILERS) · airframe 79,884 hrs · 12,873 cycles
OPERATED HYD & TURNED CONTROL WHEEL LEFT, CAN FEEL SHUTTER, VIBRATION IN COCKPIT AIRFRAME, CONTROL WHEEL & FROM INBD AILERON TO OTBD AILERON WHILE IT STILL HELD IN LT TURN. ISOLATED TO CTR HYD SYS. NO VIB IN RT & LT HYD SYS ON. RT WING AILERON OK NO VIBS. ISOLATED VIBS TO NR3 SPOILER ACTUATOR BYPASSING.
Part: PRESSURE SWITCH — FAULTED (LEFT) · airframe 79,728 hrs · 12,851 cycles
LEFT FWD BOOST PUMP LOW PRESSURE LIGHT INOPERATIVE. CLEANED CONNECTOR AND BLEED PRESSURE SWITCH LINE, NO HELP. DEFERRED PUMP INOPERATIVE. REPLACED LT FWD FUEL BOOST PUMP PRESSURE SWITCH (S70) IAW MM. CHECKED GOOD, NO LEAKS.
Part: CONTROLLER — INOPERATIVE (WINDOW HEAT) · airframe 79,125 hrs · 12,769 cycles
LT WINDOW SIDE HEAT INOPERATIVE. REPLACED M192 WINDOW HEAT CONTROLLER, WINDOW HEAT OPERATION RESTORED.
Part: LINE — LEAKING (HYD SYSTEM) · airframe 78,996 hrs · 12,748 cycles
HYD FLUID LEAKING FROM LT PYLON INBD DRAIN.
Part: LINE — LEAKING (HYD SYSTEM) · airframe 78,996 hrs · 12,748 cycles
HEAVY HYD LEAK NR 1 PYLON. SUPPLEMENTAL DATA UPDATE HYDRAULIC FLUID LEAKING FROM LEFT PYLON INBD DRAIN WHILE REVERSER DEPLOYED AND LEFT HYDRAULICS PRESSURIZED. LINE IS LOCATED BETWEEN RESERVOIR AND INTO A BULKHEAD, EXTREMELY TIGHT ACCESS. LINE REMOVAL IS IN PROGRESS. NON STOCK AOG T6833. FOUND LEAK FWD OF LH HYD RESERVOIR IN SAIL TAIL ON REVERSER PRESS LINE. REMOVED LINES AND ROUTED TO SFO. HAD DIFFICULTY SEPARATING LINE NR 20 FROM LINE NR 45. LINE NR 45 ALSO ROUTED TO SFO FOR MANUFACTURE. HAD DIFFICULTY SEPARATING LINE NR 20 FROM LINE NR 45. LINE NR 45 ALSO ROUTED TO SFO FOR MANUFACTURE. INSTALL NEW LINES AND PRESSURE TEST LINES, NO LEAKS FROM NEW LINES. REVERSER OPS NORMAL.
Part: ISOLATION VALVE — DEFECTIVE (BLEED AIR SYS) · airframe 78,966 hrs · 12,744 cycles
LEFT ISOLATION VALVE WOULD NOT OPEN. REPLACED LT ISOLATION VALVE. OPS CHECK NORMAL.
Part: CDU — FAILED (RIGHT) · airframe 78,924 hrs · 12,737 cycles
RH FMC/CDU FAILURE, FLIGHT DIVERTED. 1ST OFFICER'S CONTROL DISPLAY UNIT FOUND FAULTY. REPLACED F-O'S CDU PER AMM. RT CDU CHECKS SATIS.
Part: ENTERTAIN SYS — INOPERATIVE (CABIN) · airframe 78,301 hrs · 12,653 cycles
ENTIRE PASSENGER ENTERTAINMENT SYSTEM IS INOPERATIVE.
Part: TIRE — UNKNOWN (MLG) · airframe 77,565 hrs · 12,555 cycles
TIRE DEBRIS ON T/O ROLL, RTFL. REPLACED TIRE.
Part: IDG — FAULTY (RT ENGINE) · airframe 77,542 hrs · 12,552 cycles
RT ENG GEN DRIVE LIGHT NOT ILLUMINATED AFTER ENGINE SHUTDOWN. BPCU BITE FAULTED R IDG PRESS SWITCH OR WIRING. DISCONNECTED IDG. REPLACED IDG IAW MM. SERVICED OIL, LEAK CHECKED. NO LEAKS WERE NOTED. RAN ENGINE PERFORMED IDG DISCONNECT TEST, NORMAL OPS.
Part: UNKNOWN — ODOR (CABIN) · airframe 77,433 hrs · 12,537 cycles
CREW REPORTS IN CLIMBOUT COULD SMELL ELECTRICAL TYPE ODOR. STRONGEST FROM ROWS 6-20. ENTERTAINMENT SYS AND BUFFER BOXES TURNED OFF. ODOR DISSIPATED WHEN CRUISE WAS REACHED. INBD FLT ATT SUSPECTED SMELL COMING FROM ONE OF THE MONITORS IN BUS CLASS. RAN IFE FOR APPROX 1HR, INSPECTED CABIN AND GALLEYS. NO SMELL NOTED. RAN PACKS, RECIRC FANS ARE RUNNING, NO ELECTRICAL SMELLS NOTED. ETOPS VERIFICATION OK, CF ITEM CLEARED. NFF.
Part: PIN — OUT OF ADJUST (E/E DOOR LATCH) · airframe 77,218 hrs · 12,503 cycles
E&E DOOR EICAS MESSAGE, RTFL. FOUND FLAT SPOT OF LATCH PIN OUT OF ADJUSTMENT MORE THAN 4 DEGREES AND TARGET TOO CLOSE. REMOVED SHIMS AND ADJUSTED PIN. ADJUSTED E&E DOOR. ACCOMPLISHED CHECK OF E-E DOOR. CLEANED AND LUBED MECHANISMS AND JAR CHECKED. UNABLE TO DUPLICATE ON GROUND. NO FAULTS PSEU DUE ONLY EICAS MESSAGE. SUSPECT PSEU CARD M162. DOOR OPS CHECKED OK AT ORD .
Part: CONNECTOR — UNSECURE (CABIN) · airframe 77,217 hrs · 12,502 cycles
EMERGENCY LIGHT AT SEAT 2A INOP. SECURED CONNECTOR, OPS CHECK OK.
Part: CIRCUIT BREAKER — TRIPPED (FIRE SUPPRESSION) · airframe 76,261 hrs · 12,364 cycles
APU INOP ACCT FIRE DISCHARGE LIGHT ILLUMINATED. THIS CONDITION INDICATES A BAD PRESSURE SWITCH AND THE APU FIRE EXTINGUISHER BOTTLE SHOULD BE REPLACED. REPLACED BOTTLE ASSY, NO HELP. CREW REPORTS CB C796 APU REMOTE FIRE INDICATOR CIRCUIT BREAKER POPPED. PULLED & COLLARED. VERIFIED NO OTHER A-C SYS AFFECTED.
Part: PDU — FAULTY (AFT CARGO BAY) · airframe 76,068 hrs · 12,338 cycles
AFT CARGO PIT, AFT CARGO LOADING SYS CHECK. DURING CHECK SMOKE WAS COMING OUT FROM UNDER CARGO PIT FLOOR PANELS ON LT SIDE FWD OF CARGO DOOR. 2 EACH PDU CONTROL C-B. REPLACED PDUS AT 3L AND 7L, OPS CHECKED GOOD.
2009
Part: CONTROLLER — MALFUNCTIONED (BLEED AIR SYS) · airframe 75,484 hrs · 12,251 cycles
RIGHT BLEED LOSES PRESS WHENEVER THROTTLE IS IN LOW THRUST CONDITION. REPLACED PRESSURE REGULATING VALVE CONTROLLER. RAN ENG PNEU PRESSURE NORMAL.
Part: WIRE — SHORTED (HYDRAULIC SYS) · airframe 75,482 hrs · 12,250 cycles
LEFT SYSTEM AND LEFT DEMAND PUMP LOW PRESSURE LIGHT ILLUMINATED WITH PUMP ON AND EICAS SHOWING 3000 PSI. ISOLATED M925 TIME DELAY MODULE AND CHECK RESISTANCE FROM M925 TO LOW PRESS CONNECTOR. METER SHOWED 1.6 OR WIRE GROUNDED. ISOLATED GROUND IN WIRE BUNDLE FROM D4280P TO D52 REF WIRE DIAGRAM 29-11-12. ACCOMPLISHED WIRE CHECK FROM D52 TO APPROX 3 FEET. NO DEFECT FOUND. MOVED WIRE NEAR CON D4280P AND SHORT WENT AWAY. FOUND SHORTED WIRE PIN 4 ON WIRE W398-006-18 ABOUT 8 INCHES AFT OF D4280P. ACCOMPLISHED REPAIR. PERFORMED OPERATION. CHECK OF LT HYD PUMP IN AUTO AND ON, PRESSURES NORMAL AND NO FAULT LIGHT NOTED.
Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 75,477 hrs · 12,248 cycles
OVERWING EMERGENCY EXIT SIGN L297, L322, L699 AND L700 INOP. REPLACED M1209 EMERGENCY LIGHTS PWR SUPPLY. TEST OKAY.
Part: WINDOW — LEAKING (COCKPIT) · airframe 74,872 hrs · 12,160 cycles
LOUD PRESSURE LEAK AT CAPTAIN'S LEFT SLIDING WINDOW. SUSPECTED LEAK AREA MARKED WITH TAPE. SQUEAL STARTED AT VERY LOW CBN DIFF PRESSURE AND CONTINUED UP TO CRZ DIFF PRESSURE OF 8.6. PRESSING ANYWHERE ON THE WINDOW DID NOT MAKE ANY DIFFERENCE. REPLACED & ADJUSTED WINDOW.
Part: PANEL — DAMAGED (NR 5 SLAT) · airframe 74,272 hrs · 12,071 cycles
LEFT WING NR 5 LEADING EDGE SLAT HAS 2 SLAT CLOSURE PANELS WITH DAMAGE, 2ND FROM INBOARD PANEL HAS A 4 INCH CRACK THAT RUNS FROM THE AFT EDGE OF THE PANEL THROUGH 4 RIVET HOLES AND TERMINATES IN THE AFT HOLE, 3RD FROM INBOARD PANEL HAS SOME DELAM IN THE OUTBOARD CORNER MEASURING 0.5 BY 0.75 INCHES. ALSO A SMALL NICK OUT OF THE INBOARD CORNER. ACCOMPLISHED CHECKS AND REPAIRS PER EVA 72876. DELAMINATED PLY STOP DRILLED. BOTH PANELS CHECKED FOR FURTHER DELAMINATION AND MOUNTING BRACKETS CHECKED FOR CRACKS OR DAMAGE. NO FURTHER DAMAGE. TAPED PANELS WITH SPEED TAPE AND OPERATED FLAPS AND OPERATION NORMAL. THIS INTERIM REPAIR FOR 50 FLT HRS (MAX PTT 74322) WITH REQUIRED RE-INSPECTION OF THE ALUMINIUM SPEED TAPE FOR DETERIORATION AND A DETAILED VISUAL INSPECTION OF THE AREA EVERY FLT. RE-APPLY SPEED TAPE AS REQUIRED.
Part: COFFEEMAKER — CONTAMINATED (FWD GALLEY) · airframe 74,095 hrs · 12,043 cycles
STRONG ELECTRICAL ODOR EMANATING FROM SEAT 2A. CHECKED ALL AREAS AROUND SEAT 2A AND 1A. ALSO FWD CARGO PIT AREA. FOUND ALL TO BE GOOD. ALSO INOP SEAT 2A ELECTRICAL. RETURNED TO BLOCK A 2ND TIME FOR ELEC ODOR AT SEAT 2A. INSPECTED SEAT, FOUND NO ABNORMALITIES, CYCLED SEAT NUMEROUS TIMES, RAN ENGINES AND PACKS FOR 20 MINUTES, PERFORMED EMERGENCY LIGHT TEST AND FOUND NO ABNORMAL ELEC ODOR IN CABIN OR THE E&E COMPARTMENT. FELT SIDEWALL PANELS AND SEAT AREA FOR HOT SPOTS, NONE FOUND. MECH FOUND PLASTIC ON COFFEEMAKER IN FWD GALLEY AND REPLACED.
Part: CONTROLLER — FAILED (CABIN PRESSURE) · airframe 73,585 hrs · 11,965 cycles
CABIN CLIMB EXCESS 2000FPM WITH BOTH PACKS OFF. REPLACED CABIN PRESSURE CONTROLLER. OPS CHECKS GOOD. PERFORMED CABIN LEAK CHECK, LEAK CHECKS GOOD.
Part: FMC — DEFECTIVE (RIGHT) · airframe 72,868 hrs · 11,857 cycles
RIGHT FMC FAILED. RTFL. CYCLED C/B FOR RIGHT FMC, MESSAGE CLEARED AND OPS CHECKS GOOD. RT FMC NEEDS PRECAUTIONARY REPLACEMENT DUE TO FMC FAILURE IN FLIGHT. REPLACED RT FMC. CLOSED BOTH BREAKERS FMC WILL NOT SYNC GIVES MESSAGE RESYNC FAILED SINGLE FMC WITH RT FMC FAILED EICAS. WITH JUST RT BREAKER IN RT OPERATES WITH CORRECT OPS SOFTWARE PN DISPLAYED. NAV DATA DRAG FACTOR AND FF FACTOR INCORRECT. REPLACED FMC. CORRECT OP SOFTWARE INSTALLED PS4052970-959. FMC CHECKS OK, NO FAULT LIGHTS.
Part: LENS — BROKEN (EXTERIOR) · airframe 72,379 hrs · 11,784 cycles
FUSELAGE EXTERIOR EMERGENCY LIGHT LENS BROKEN RT SIDE APPROX 24 INCHES FWD OF AFT PIT DOOR. REMOVED AND REPLACED EMERGENCY LIGHT LENS.
Part: LENS — BROKEN (EXTERIOR) · airframe 72,379 hrs · 11,784 cycles
FUSELAGE EXTERIOR EMERGENCY LIGHT LENS BROKEN RT SIDE APPROX 24 INCHES FWD OF AFT PIT DOOR. REMOVED AND REPLACED EMERGENCY LIGHT LENS.
Part: SLIDE — LOW PRESSURE (L2 DOOR) · airframe 72,210 hrs · 11,756 cycles
DOOR 2L SLIDE PRESSURE BELOW SERVICEABLE LIMIT. REPLACED 2L SLIDE.
2008
Part: ACTUATOR — FAULTY (AILERONS) · airframe 71,682 hrs · 11,677 cycles
THE "AIL LOCK" LT ON AT LOW SPEED. EICAS MSG AILERON LOCKOUT DISPLAYED. REPLACED RIGHT WING AILERON LOCKOUT ACTUATOR. REPLACED RT WING AILERON LOCKOUT ACTUATOR. TESTED NORMAL. RECEIVED SAME EICAS SEVERAL FLIGHT SEGMENTS LATER. REPLACED RIGHT SAM AND RT ADC (P/N S242T210-211). MCDP TEST 30 AND 65 CHECKS OK.
Part: OIL FILTER — DEFECTIVE (RT ENGINE) · airframe 70,638 hrs · 11,535 cycles
THE 'R OIL FILTER' STATUS MSG DISPLAYED. REPLACED MAIN OIL FILTER & ENGINE OIL SCREEN. ENG RUN PERFORMED. NO LEAKS NOTED AND NO FURTHER MSG DISPLAYED.
Part: WARNING SYSTEM — ACTIVATED (COCKPIT) · airframe 70,638 hrs · 11,535 cycles
THE 'R OIL FILTER' STATUS MSG DISPLAYED.
Part: ACTUATOR — MALFUNCTIONED (FUEL SYSTEM) · airframe 70,598 hrs · 11,530 cycles
FUEL SHUTOFF VALVE PROBLEM. RTBL. REPLACED SPAR VALVE ACTUATOR. OP CHECKS GOOD.
Part: CONTROL UNIT — FAILED · airframe 70,276 hrs · 11,485 cycles
EICAS MSG (L,R) UTIL BUSS OFF DISPLAYED. UTILITY BUSS OFF LGT ILLUM. SYS FAILED TO RESET. BUSS PCU FAILURE. REPLACED BUSS POWER CONTROL UNIT.TESTS OKAY. RAN BOTH ENGINES & RAN ALL ELECTRICAL POWER SYSTEMS USING ALT BUSSES ALL INDICATION & OPS NORMAL.
Part: FILTER — UNKNOWN (ENGINE OIL) · airframe 70,016 hrs · 11,447 cycles
LT ENGINE OIL FILTER STATUS MESSAGE. *S/D* REPLACED MAIN OIL FILTER.
Part: HYDRAULIC SYSTEM — LEAKING · airframe 69,481 hrs · 11,362 cycles
HYDRAULIC FLUID LOSS. FLIGHT DIVERTED.
Part: LIGHT — INOPERATIVE (COCKPIT) · airframe 69,430 hrs · 11,355 cycles
THE L ENG OIL PRESS LIGHT IS NOT ILLUMINATED ON FORWARD 1ST PANEL.
Part: IDG — FAULTY (NR 1) · airframe 69,257 hrs · 11,332 cycles
L GEN DRIVE LIGHT CONTINUOUSLY FLICKERS IN FLIGHT. GEN WORKS NORMALLY. *S/D* SUSPECT FAULTY INTEGRATED DRIVE GENERATOR. REPLACED LEFT IDG PER MM 24-11-01, ALL OPS AND INDICATE NORMAL. AC OK FOR SERVICE.
Part: SHUTOFF VALVE — FAULTY (COOLING FAN) · airframe 69,196 hrs · 11,324 cycles
EQUIPMENT COOLING FAN EICAS MESSAGE. AFTER TROUBLESHOOTING FOUND SHUTOFF VALVE TO BE FAULTY. REPLACED VALVE PER MM 21-23-08, ALL OPS & INDICATIONS NOW NORMAL. AC OK FOR SERVICE.
Part: SKIN — GOUGED (FUSELAGE) · airframe 69,120 hrs · 11,309 cycles
DEEP GOUGE ON FUSE SKIN AT STA 256.25 TO 276 AND STR 31R, JUST AFT OF CREW O2 DISCHARGE. MAJOR REPAIR ACCOMPLISHED: REMOV'D DAMAGED SKIN, INSTALLED DOUBLER REPAIR.
Part: TRIM SYSTEM — INOPERATIVE (RUDDER) · airframe 68,952 hrs · 11,273 cycles
LEFT RUDDER TRIM INOP.
Part: FAN — FAULTY · airframe 68,859 hrs · 11,259 cycles
"FWD DET FAN" MAINTENANCE MESSAGE, WILL NOT CLEAR. SUSPECT FAULTY FAN AND OR PRESSURE SWITCH. REPLACED FAN AND PRESSURE SWITCH OPS CHECK GOOD MESSAGE CLEARED. AC OK FOR SERVICE.
Part: MASK — CRACKED (COCKPIT) · airframe 68,450 hrs · 11,195 cycles
SMOKE MASK ON CAPTAIN'S SIDE IS CRACKED.
Part: CONTROL VALVE — FOD (A/C PACK) · airframe 68,441 hrs · 11,194 cycles
LEFT PACK FAILED ON TAKEOFF WITH PACK INOP AND PACK OFF DISPLAYED RESET NORMAL BUT HAD PLASTIC BURNING SMELL AND ALSO A RATTLING SOUND IN DUCTING AREA ABOVE SEAT 9C. CREW SELECTED PACK OFF AGAIN AND BURNING SMELL AND RATTLE STOPPED. FOUND LEFT PACK CONTROL VALVE NOT OPENING FULLY FOUND PLASTIC IN BUSINESS CLASS WARMING OVEN, REMOVED PLASTIC. REPLACED VALVE PER MM 21-51-01. PACK OPS CHECKS NORMAL. AC OK FOR SERVICE.
Part: LIGHT — LOOSE (CABIN) · airframe 68,436 hrs · 11,193 cycles
EMERGENCY EXIT PATH LIGHTING IN FIRST CLASS IS LOOSE. SECURED LIGHT OPS CHECKED GOOD. AC OK FOR SERVICE.
Part: CAP — MISSING (CABIN) · airframe 67,813 hrs · 11,104 cycles
EEL END CAP MISSING, BY 1E. REPLACED END CAP. OPS CHECKS GOOD.
Part: BATTERY — DISCHARGED (CABIN) · airframe 67,639 hrs · 11,077 cycles
THE M736 BATTERY FOR LEFT EXTERIOR EMERGENCY LIGHTS IS INOP. REPLACED BATTERY (M736), OPS CHECKS GOOD.
Part: SILL — CORRODED (BS 566-569) · airframe 67,639 hrs · 11,077 cycles
FWD PIT FLOOR LWR DOOR SILL CORRODED STA 566 TO 569 RBL 42 TO RBL 43. SUSPECT MOISTURE CONTAMINATION. CORRODED SILL. FWD CARGO DOOR LOWER SILL, STA 566-569, BL42R TO BL43R REPAIRED ON WU 35948 DURING C12 VISIT. UA-EVA-71016A. ACFT OK FOR SERVICE.
Part: FITTING — CRACKED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles
AFT CARGO BAY, STA 1285, RBL 42, AFT SIDE OF FRAME UPPER FITTING IS CRACKED. REPLACED FITTING REF SRM 51-40-02. FAB FITTING REF BAC DWG 146T8068 AND REO-G1221 REV-A BY MECH, AND INSP QC.
Part: WIRE — BROKEN (L1 DOOR) · airframe 67,639 hrs · 11,077 cycles
L1 DOOR LWR EMERGENCY EXIT IDENTIFIER SIGN L979 WIRES ARE BROKEN.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 67,639 hrs · 11,077 cycles
AFT LEFT AND RIGHT LAV EEL LIGHT BARS ARE INOP.
2007
Part: LIGHT — INOPERATIVE (CABIN) · airframe 67,639 hrs · 11,077 cycles
FS-3 LAV EMERGENCY LIGHT PATH BAR INOP AT LAV DOOR.
Part: WEB — CRACKED (LT WING) · airframe 67,639 hrs · 11,077 cycles
LEFT WING FIXED LEADING EDGE FORWARD WEB CRACK LOWER AREA AT STA 654. MAJOR REPAIR ACCOMPLISHED: STOP DRILLED CRACK. FABRICATED & INSTALLED DOUBLER REPAIR.
Part: CASE — CRACKED (O2 SYSTEM) · airframe 67,639 hrs · 11,077 cycles
SUPPLEMENTAL - O2 CASE CRACKED.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles
AFT CARGO BAY, STA 1131, RBL 36, TEE CAP CORRODED UNDER NUT PLATES.
Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles
MAIN CABIN GALLEY FLOOR SUPPORT CORRODED AT STA 790 TO 800 BL 9R TO 10R.
Part: HOSE — COLLAPSED (EVAC SLIDE) · airframe 67,639 hrs · 11,077 cycles
RIGHT OVERWING SLIDE INFLATION HOSE COLLAPSED.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles
AFT PIT "T" CAP CORRODED STA 1197, LBL 34 TO LBL 41.
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 67,639 hrs · 11,077 cycles
FLOORBEAM CRACKED IN UPPER CHORD BS 325 LBL 10 AND ADJACENT FASTENER SHEARED.
Part: STIFFENER — CRACKED (NLG WW) · airframe 67,639 hrs · 11,077 cycles
LEFT VERTICAL STIFFENER IN NOSE WHEEL WELL, BS 287, HAS ONE HALF INCH CRACK IN THE RADIUS. CRACK BEGINS 11.375 INCHES FROM NWW UPPER CEILING WEB.
Part: SPRING — WEAK (PAX DOOR) · airframe 67,639 hrs · 11,077 cycles
LEFT FWD MAIN ENTRY DOOR DEPLOYMENT BAR GAS SPRING IS WEAK.
Part: SLIDE — FAULTY (CABIN) · airframe 67,639 hrs · 11,077 cycles
RIGHT OVERWING SLIDE AFT AREA, ARM CAM OF SLIDE HITTING STOP BLOCK FITTING.
Part: CYLINDER — DEFECTIVE (EVAC SLIDE) · airframe 67,639 hrs · 11,077 cycles
RIGHT OVERWING ESCAPE SLIDE CYLINDER DEPLOYMENT CABLE BALL IS BELOW SPRING FORCE RETAINER.
Part: SLIDE — FAULTY (CABIN) · airframe 67,639 hrs · 11,077 cycles
LEFT OVERWING SLIDE AFT AREA, ARM CAM OF SLIDE HITTING STOP BLOCK FITTING.
Part: OXYGEN MASK — LEAKING (COCKPIT) · airframe 66,250 hrs · 10,857 cycles
CAPTAIN'S OXYGEN MASK HEAD STRAPS LEAKS AIR WHEN INFLATED. REPLACED MASK PER MM 35-11 -51.CKS GOOD.
Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 66,221 hrs · 10,852 cycles
EMERGENCY EEL LIGHT INOP FROM SEAT 31HJ TO 39 HJ. REPLACED BATTERY POWER SUPPLY.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 65,738 hrs · 10,766 cycles
EXTERNAL EEL LIGHT JUST AFT OF LEFT WING IS INOP. [07-27-07] RELAMPED AND LIGHT CHECKS GOOD.
Part: ENGINE — SURGES (NR 2) · airframe 64,693 hrs · 10,593 cycles
NR 2 ENG SURGED DURING GROUND RUN FOR BLEED T-S. [SUP 05-18-07] ACCOMPLISHED NR 2 ENGINE VISUAL CHK. REPLACED IDG OIL AND SCAV. OIL FILTER. INSPECTED MAG CHIP DET. PER MM79-21-1 0 601. NR 2 ENGINE REQUIRES BORESCOPE PER TROUBLESHOOTING OF SMC2. BORESCOPED C5,C6,C14,C15, T1&T2 AS REQ IN MM 71-05-00. FOUND ALL OK FOR INTERVAL-1. A/C RETURNED TO SERVICE.
Part: FEEDER CABLE — DAMAGED (EMERGENCY LIGHTS) · airframe 64,262 hrs · 10,515 cycles
EMERGENCY EEL LIGHTS INOP FROM SEATS 30HJ TO AFT GALLEY. SUPPLEMENTAL DATA UPDATE REPAIRED EEL STRIPS FEEDING LEFT REAR OF AIRCRAFT. OP CHECKS OK.
2006
Part: CONNECTOR — DISCONNECTED (EMERGENCY LIGHT) · airframe 62,857 hrs · 10,263 cycles
EMERGENCY EEL LIGHT STRIP INOP AT RT MID LAV.
Part: BRAKE — FIRE (MLG) · airframe 61,348 hrs · 10,017 cycles
NR 4 MAIN TIRE-BRAKE FIRE AFTER A/C PARKED WITH BRAKES RELEASED. THE PROBLEM WAS CAUSED BY THE BUILD UP OF GREASE ON THE WHEEL AXLE DURING SERVICING, DURING WHILE/ TIRE CHANGE OR BRAKE INSTALLATION. FIRE WENT OUT WITHOUT NEEDING FIRE EXTINGUISHER. REPLACED 4R BRAKE AND TIRE. INSPECTED GEAR FOR HEAT DAMAGED. FOUND NONE. AMM 32-45-01/401 WHEEL AND TIRE INSTALLATION, ADVISES TECHNICIANS TO FOLLOW THE FOLLOWING PROCEDURES TO PREVENT CONTAMINATION OF THE WHEEL/TIRE ASSEMBLY; REMOVE CONTAMINATION AND UNWANTED MATERIAL FROM THE INSTALLATION COMPONENT OF THE LANDING GEAR. APPLY THIN LAYER OF WHEEL BEARING GREASE TO THE AXLE WHERE IT WILL CONTACT THE INNER AND OUTER SURFACES OF THE WHEEL BEARINGS.
Part: INDICATOR — MALFUNCTIONED (COCKPIT) · airframe 61,113 hrs · 9,982 cycles
EQUIP COOLING MONITOR EHSI-L, VOR-L AND FMCDU-L BALL INDICATORS DONT GO UP IN TEST. CONFIRMED RESPECTIVE SENSI NG LINES STATIC PRESSURE ABOVE 0.80 INCHES OF WATER AS PER MEL. ONLY VOR-L FAILING. CK'D AIRFLOW TO VOR-L,FOUND NORMAL. SECURED LOOSE HOSES AT MONITOR STILL NO HELP. REPLACED MONITOR. OP CHEKD OK FOR SERVICE.
Part: WARNING SYSTEM — ACTIVATED (COCKPIT) · airframe 60,753 hrs · 9,924 cycles
AILERON LOCKOUT EICAS DURING DESCENT FL110 250 KIAS. CLEANED AND SECURED CANON PLUG ON RIGHT ACTUATOR. OPS OK NOW.
2005
Part: STIFFENER — CRACKED (FLOORBEAM) · airframe 55,296 hrs · 9,048 cycles
FLOORBEAM AT STA 246 HAS A CRACKED VERTICAL STIFFENER ON FWD FACE OF BEAM AT APPROX LBL 26. REPLACED CRACKED STIFFENER.
Part: RIB — CRACKED (RT WING) · airframe 55,296 hrs · 9,048 cycles
RT WING L-E CAVITY AT FSS 512, UPPER RIB LOWER CHORD PREVIOUS REPAIR CRACKED AT AFT END-OUTBD OF NR 8 SLAT OUTBD ACTUATOR. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. RIB REPAIRED WITH ANGLE DOUBLER.
Part: STIFFENER — CRACKED (FLOORBEAM) · airframe 55,296 hrs · 9,048 cycles
FLOORBEAM AT STA 246 HAS A CRACKED VERTICAL STIFFENER ON FWD FACE OF FLOORBEAM AT APPROX RBL 26.39. CRACKED STIFFENER WAS REPLACED.
2003
Part: COMPRESSOR — LEAKING (NR 1 ENGINE) · airframe 49,841 hrs · 8,135 cycles
NR 1 ENGINE SURGE ON TAKEOFF. ENGINE SELF RECOVERED AND CONTINUED NORMAL OPERATION. ENGINE EXPERIENCED GROUP 3 SURGE ON TAKE OFF. CAUSE OF THE SURGE IS OPEN CLEARANCES IN THE REAR OF THE HPC. FINAL FIX FOR SURGE ISSUES IS THE OVERHAUL OF THE ENGINE TO A RING CASE CONFIGURATION.
2002
Part: CIRCUIT CARD — FAULTY (NR 10) · airframe 45,265 hrs · 7,356 cycles
EICAS "LE SLAT ASSY" AND ASSOCIATED LIGHT ILLUMINATED WITH INDICATED 1 DEGREE FOR BOTH LEFT AND RIGHT. TROUBLESHOT SYSTEM PER FAULT ISOLATION MANUAL. FOUND A5 DRIVER CARD IN THE NR 10 POSITION IN THE PROXIMITY SWITCH ELECTRONIC UNIT FAULTED. REPLACED CARD SYSTEM OP CHECKS OK.
Part: SCREW — BACKED OUT (LT ENGINE) · airframe 45,095 hrs · 7,323 cycles
NO OIL PRESSURE IN LEFT ENGINE, ENGINE SHUTDOWN. FLIGHT LANDED WITHOUT INCIDENT. OIL PUMP DRIVE GEAR FAILURE. REF IPC 72-61-00-019: OIL PUMP DRIVE BEARING AND GEAR ASSY WERE FOUND LOOSE AND COCKED IN THE GEARBOX BEARING BORE. BEARING RETAINING SCREWS WERE BACKED OUT OF THE GEARBOX HOUSING AND LAYING IN THE BOTTOM OF THE GEARBOX. THIS RESULTED IN FRACTURE OF THE OIL PUMP DRIVE MODULE GEAR SHAFT IN THE WEB OF THE GEAR. ENGINE WILL REQUIRE OVERHAUL OF ALL BEARINGS DUE TO LOSS OF OIL PRESSURE.MAIN GEARBOX WILL BE OVERHAULED.
Part: WIRE HARNESS — FAULTY (CABIN) · airframe 43,739 hrs · 7,061 cycles
SECTION OF FLOOR EMERGENCY EXIT LIGHT BEGINNING AT RIGHT SIDE CLOSET AT MID GALLEY AND ENDING AT AFT EDGE OF MID LAV FORWARD OF ROW 15 IS INOPERATIVE. REPAIRED CABLE EMERGENCY ESCAPE PATH LIGHTING.
Part: BULKHEAD — PUNCTURED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 246 RBL 50 BULKHEAD WEB IS PUNCTURED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 832 RBL II TRANSBEAM UPPER CAP IS CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED SPLICES.
Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
CHAFED LOWER SKIN AFT OF STATION 1725.5 ABOVE STRINGER 22 LT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER.
Part: CLIP — BROKEN · airframe 43,180 hrs · 6,953 cycles
FLOOBEAM ATTACH CLIP BROKEN STATION 390LH, FORWARD PIT ABOVE STRINGER 33L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW CLIP.
Part: SPLICE — GOUGED · airframe 43,180 hrs · 6,953 cycles
STATION 880, RBL 54, TRANSBEAM OUTBOARD SPLICE GOUGED BEYOND LIMITS. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICE.
Part: SPLICE — GOUGED · airframe 43,180 hrs · 6,953 cycles
STATION 880, RBL 33, TRANSBEAM INBOARD SPLICE IS GUOGED BEYOND LIMITS. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED SPLICE.
Part: DOOR FRAME — CORRODED (L2 DOOR) · airframe 43,180 hrs · 6,953 cycles
L-2 DOOR CHORD HAS SEVERE CORROSION-EXFOLIATION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FILLER AND DOUBLER.
Part: CAP — CORRODED · airframe 43,180 hrs · 6,953 cycles
CABIN STAION 832-RBL 11, TRANSBEAM UPPER CAP IS CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED WITH SPLICE BEAM.
Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
FUSE SKIN CHAFED, FORWARD SKIN, STATION 1725.5 AT STRINGER 22 RT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR DOUBLER.
Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
CHAFED LOWER SKIN AFT OF STATION 1725.5 ABOVE STRINGER 22 RT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR DOUBLER.
Part: CLIP — BROKEN · airframe 43,180 hrs · 6,953 cycles
FLOOR BEAM ATTACH CLIP BROKEN STATION 434 LFT HAND, FORWARD PIT ABOVE STRINGER 33L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED CLIP.
Part: SKIN — CHAFED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
LEFT HAND FUSELAGE SKIN CHAFED AFT OF STATION 1809.5 AT STRINGER 17. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR DOUBLER.
Part: BULKHEAD — PUNCTURED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
CABIN STATION 246, RBL 50, BULKHEAD WEB IS PUNCTURED. MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED DOUBLER.
Part: CAP — CORRODED · airframe 43,180 hrs · 6,953 cycles
CABIN STATION 832, RBL 11, TRANSBEAM UPPER CAP IS CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED SPLICE.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 800-852 LBL 54.81 TRANSVERSE BEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICES.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 852 RBL 54-81 TRANSVERSE BEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICES.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
CABIN STATION 850, LBL 33, TRANSBEAM UPPER CAP IS CORRODED. MAJOR REPAIR ACCOMPLISHED. REPAIRED TRANSBEAM WITH NEW SECTION AND SPLICE ANGLES.
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
CABIN FLOORBEAM STATION 303, RBL 88 IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPAIRED FLOORBEAM NEW SECTION WITH SPLICE ANGLES.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 852 RBL 33 TRANSBEAM CORRODED ON UPPER CAP. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR SPLICES.
Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 800 LBL 11 TRANSBEAM UPPER CHORD IS CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED TRANSBEAM AND SPLICES.
Part: FRAME — CORRODED (FUSELAGE) · airframe 43,180 hrs · 6,953 cycles
BODY STATION 287 RBL 88 CHORD CORRODED AT CHORD LOCATED AT R-1 DOOR. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW CHORD.
Part: SKIN — GOUGED · airframe 43,180 hrs · 6,953 cycles
BODY STATION 785 STRINGER 1-2 FUSELAGE SKIN IS GOUGED BODY STATION 785 LEFT HAND SIDE, STRINGER 1L-2L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER REPAIR.
2001
Part: FAN — ODOR (COCKPIT) · airframe 39,783 hrs · 6,375 cycles
CREW EXPERIENCED BURNING ODOR IN COCKPIT AND FOUND EQUIP EXHAUST FAN 1 CB TRIPPED.
Part: ENGINE — LEAKING (NR 1) · airframe 39,736 hrs · 6,368 cycles
NR 1 ENGINE SHUTDOWN DUE CONFIRMED FUEL LEAK. DIVERTED SDF.
Part: STRINGER — DAMAGED (FUSELAGE) · airframe 39,516 hrs · 6,324 cycles
STRINGER 32R AT BS 1200 HAS A FIGURE EIGHT SHAPED FASTENER HOLE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHEDREPAIRED PER SRM 51-20-07 AND SRM 53-00-01.
Part: GROUND WIRE — DAMAGED (BATTERY) · airframe 38,872 hrs · 6,203 cycles
APU BATTERY GROUND GD3072DC OVERHEATED. INSULATION BLANKETS HEAT DAMAGED. *S/D* ACCOMPLISHED DETAILED VISUAL INSPECTION OF ALL EFFECTED WIRE BUNDLES AND INSTALLATIONS LOCATED IN E6-1 SHELF AND P49 PANEL. ALL WIRING CHECKED OK, EXCEPT APU BATTERY GROUND WIRE. REPLACED APU BATTERY GROUND BRACKET (P/N 287T0152-4), APU BATTERY GROUND WIRE W1048-007-1/0 AND GROUND GD3072DC HARDWARE.
2000
Part: BLADE — CRACKED (COMPRESSOR) · airframe 34,102 hrs · 5,342 cycles
RIGHT ENGINE SUFFERED A FLAME-OUT DURING INITIAL CLIMB FROM FL330 TO FL370. TWO RESTARTS ATTEMPTED WITH NO HELP. ENGINE SURGED AT FL330 NO VIBRATION. AFTER LANDING MECHANIC FOUND METAL IN TAILPIPE. *S/D* C5 BLADE FAILURE DUE TO IMPACT DAMAGE. BLADE WAS IMPACTED BY MATERIAL LIBERATED BY C5 DISK INTEGRAL KNIFE EDGE AIRSEAL. PRATT & WHITNEY SERVICE BULLETIN 72-653 CORRECTS THIS FAILURE MODE BY REMOVING C5 KNIFE EDGE SEAL FORWARD LAND.
1999
Part: RETRACT MECH — MALFUNCTIONED (TE FLAPS)
ON FLAP RETRACTION DURING TAKEOFF (FLAPS 5), WHEN FLAPS 1 WAS CALLED FOR FLAPS STUCK AT ABOUT 3.5 DEG. TE FLAP DISAGREE EICAS MESSAGE WITH MASTER CAUTION PROCEDURE ON 7-43 WAS ACCOMPLISHED PER FLIGHT MANUAL.
Part: STARTER — DEFECTIVE (APU)
APU AUTO SHUTDOWN WITH 'APU OIL QTY' EICAS MSG DISPLAYED. DIVERTED TO ASU . *S/D* APU STARTER WAS FOUND LEAKING WHICH CAUSED THE LOP SHUTDOWN. REPLACED APU STARTER PER ENGINEER'S UPDATE. ALSO, REPLACED GEARBOX SHUTOFF VALVE AS A PRECAUTIONARY ACTION. SERVICED APU WITH OIL AND TESTED OK WITH NO FURTHER LEAKS AND OPERATION BACK TO NORMAL.
Part: IDG — INOP (LEFT)
AIRCRAFT DISPATCHED WITH LT INTEGRATED DRIVE GENERATOR (IDG) INOP. APU AUTO SHUTDOWN CAUSING APU GENERATOR AND UTILITY BUSSES TO TRIP. FLIGHT DIVERTED TO MSY. REPLACED LT IDG. SHOP FOUND CONTAMINATION IN IDG SYSTEM.
1997
Part: COMPRSSOR — DETERIORATED (RT ENGINE)
RIGHT ENGINE COMPRESSOR STALL. RETURN TO FIELD. ENGINE WAS NOT SHUT DOWN, OVERWEIGHT LANDING. *S/D* ENGINE SURGED ON TAKEOFF DUE TO GENERAL DETERIORATION OF THE HIGH PRESSURE COMPRESSOR AND EXCESSIVE BLADE TIP CLEARANCES. ENGINE WAS REPLACED.
1996
Part: OVEN — SMOKING (GALLEY)
USED FIRE EXTINGUISHER FOR SMOKE AND FUMES FROM GALLEY OVEN. FOUND MELTED PLASTIC MATERIAL ON HEATING ELEMENT GRILL IN OVEN. OVEN OPERATED NORMALLY AFTER PLASTIC MATERIAL WAS REMOVED.
Part: DOOR LIGHT — ILLUMINATED (CARGO DOOR)
AIRCRAFT RETURNED TO IAD DUE TO CARGO DOOR LIGHT. *S/D* BUILT IN TEST EQUIPMENT INDICATED LOGIC CARD 3 FAILED IN THE PROXIMITY SWITCH ELECTRONIC UNIT. REPLACED LOGIC CARD, OPERATIONS CHECK NORMAL.
1995
Part: BEARING — FAILED (NR 2 GEAR BOX)
OIL FILTER BY-PASS LIGHT FOR THE NUMBER TWO ENGINE CAME ON, CREW BROUGHT BACK THROTTLE TO IDLE. SHORTLY, THEREAFTER THE NUMBER TWO ENGINE FLAMED-OUT. ANGLE GEARBOX BEARING FAILED.
Part: VALVE — MALFUNCTION (STARTER)
STARTER VALVE, AND STARTER SEQUENCE LIGHT ILLUMINATED DURING FLIGHT. AIRCRAFT RETURNED TO FIELD. UNABLE TO FIND FAULT WITH VALVE. OVERHAULED IT AS A PRECAUTION AND RETURNED TO STOCK.