FABRICATE ANGLE BRACKET FOR AFT ACCESSORY COMPARTMENT BETWEEN FR74 AND FR 75 STR 19R PER DRAWING PN 145-27014-001 OUT OF 2024T3 0.040 SEE DRAWING ATTACHED FILE NAME 145-27014. FABRICATED (1 EACH) ANGLE-FLOOR, REAR FUSLG I, AL PN 145-27014-001 PER DRAWING 145-27014 AND E01-05-26-0228.
00664 UPON GIVING OK TO CLOSE CARGO FLOOR PANEL, FOUND 1EA CLIP ON RH OMEGA BEAM AT FR 74 BROKEN. INSTALLED FABRICATED CLIP P/N 145-27014-001 ON R/H OMEGA BEAM AT FR 74 -FR 75 PER EMB 145 SRM 51-40-02-PR, AND EO-1-05-26-0228.
DURING A DOUBLER INSTALL FOUND ADDITIONAL CORROSION ON LH FLOOR SILL AT FR 40. FABRICATED AND INSTALLED DOUBLER ON MID CABIN LH FLOOR SILL AT FR40 IAW ETD 2026-145-008549 REV: B. SEE MAJOR EO# EO1-53-26-0243
00619 MID OMEGA BEAM FR 24 TO 25 AREA FOUND TO BE OUT OF LIMITS REQUIRES REPAIR. REPAIRED OUT OF LIMITS CORROSION ON MID OMEGA BEAM AT FR 24 TO FR 25 WITH A DOUBLER IAW EMB 145 SRM 53-22-10-RE SECTION 4 SEE PIEDMONT MAJOR EO1-53-26-0251
00543 RH ELEVATOR UPPER CENTER HINGE DOUBLER IS CRACKED. REMOVED AND REPLACED RH ELEVATOR UPPER CENTER HINGE DOUBLER IAW EMB 145 SRM 55-20-01 REPAIR TYPE A, SECTION A - A, FIG. 229 SEE PIEDMONT MAJOR EO1-55-26-0240
00556 DURING REMOVAL OF SERVICE DOOR LOWER SURROUND STRUCTURE FLOOR SILL FOUND FWD SEALING SUPPORT TO BE CORRODED AND CRACKED. REMOVED AND REPLACED SERVICE DOOR LWR FWD SUPPORT P/N 145-25136-001 PER EMB 154 SRM 51-40-02-PR STEP 2.B, AND 2.C.
DURING REMOVAL OF SERVICE DOOR LOWER SURROUND STRUCTURE FLOOR SILL FOUND AFT SEALING SUPPORT TO BE CRACKED AND CORRODED. REMOVED AND REPLACED SERVICE DOOR LWR AFT SUPPORT P/N 145-25136-002 PER EMB 154 SRM 51-40-02-PR STEP 2.B, AND 2.C.
AFTER REMOVAL OF RH FLOOR GUSSET AT FR 22 FOUND CORROSION AROUND THE FWD NUTPLATE HOLE PERFORMED CUTOUT AND INSTALLED DOUBLER ON THE RH OMEGA BEAM AT FR 22 AROUND FWD NUTPLATE HOLE IAW ETD2026-145-008618. PIEDMONT MAJOR EO# EO1-53-26-0244 NUTPLATE HOLE.
00523 MULTIPLE AREAS OF CORROSION ON SERVICE DOOR LOWER FRAME. REPAIRED OUT OF LIMITS CORROSION ON GALLEY SERVICE DOOR LOWER FRAME PER EMB 145 SRM 52-43-06 SECTION 2. SEE PIEDMONT MAJOR EO# EO1-52-26-0247
PANEL 191 LR HAS CORROSION IN MULTIPLE LOCATION. RAR PANEL AND APPLIED SURFACE PROTECTION TO NEW PANEL 191LR PER EMB 145 CPM 51-21-04, CPM 51-21-05, CPM 51-21-06.
00413 FUSELAGE EXTERNAL SKIN AT FR 7, STR 15L, UNDER GPU ACCESS DOOR HAS A GOUGE. PERFORMED CUTOUT AND INSTALLED FABRICATED FILLER AND DOUBLER TO FUSELAGE EXTERNAL SKIN AT FR 7 STR 15L UNDER GPU ACCESS DOOR IAW EMB 145 SRM M53-12-01-RE STEP 2 FIGURE 201 SEE PIEDMONT MAJOR EO# EO1-53-26-0246.
LH ENGINE THRUST REVERSER OUTBRD SKIN BETWEEN PNLS 416SL AND 416UL AND AFT OF PANELS HAS MAJOR CORROSION UNDERNEATH SKIN AND PULLING PAST RIVITS. MAJOR SKIN BUBBLES AND VOIDS/DISBONDING. LH ENG THRUST REVERSER RAR IAW EMB AMM
RH FLOOR SILL FROM FR 32 FR 35 HAS CORROSION. REMOVED AND REPLACED WITH NEW MID CABIN RH FLOOR SILL FROM FR 32 TO FR 35 IAW EMB 145 SRM 51-40-02-PR, SECTION 2
MID OMEGA BEAM GUSSET FROM FR 32 TO FR 36 HAS CORROSION. REMOVED AND REPLACED WITH NEW MID CABIN MID OMEGA BEAM GUSSET FROM FR 32 TO FR 36 IAW EMB 145 SRM 51-40-02-PR
00272 LH OMEGA BEAM GUSSET FROM FR 36 TO FR 38 HAS CORROSION. REMOVED AND REPLACED WITH NEW LH OMEGA BEAM GUSSET FROM FR 36 TO FR 38 IAW EMB 145 SRM 51-40-02 STEP 2, B.
00271 LH FLOOR SILL FROM FR 36 TO FR 39 HAS CORROSION. FABRICATED AND INSTALLED DOUBLER ON MID CABIN LH FLOOR SILL AT FR39 IAW ETD 2026-145-008549 REV: B. SEE PIEDMONT MAJOR EO# EO1-53-26-0243
RT FLOOR SILL FROM FR 41 TO FR 48 HAS CORROSION. REMOVED AND REPLACED MID CABIN RT FLOOR SILL FROM FR 41 - FR 48 PER EMB 145 SRM 51-40-02-PR.
LT OMEGA BEAM GUSSET FROM FR 38 TO FR 44 HAS CORROSION. REMOVED CORROSION FROM MID CABIN, 1EA LH OMEGA BEAM GUSSET FROM FR 38 TO FR 44. FOUND IN LIMITS
00254 LH OMEGA BEAM GUSSET FROM FR 50 TO FR 53 HAS CORROSION. REMOVED AND REPLACED MID CABIN LH OMEGA BEAM GUSSET FROM FR 50 TO FR 53 IAW SRM 51-40-02-PR
00253 CORROSION RH SILL BETWEEN FRAMES 65 AND 66. REMOVED AND REPLACED RH FLOOR SILL FROM FR 65 - FR 66 PER EMB 145 SRM 51-40-02-PR.
00249 RH FLOOR SILL AT FR 48 HAS CORROSION. REMOVED AND REPLACED MID CABIN RH FLOOR SILL AT FR 48 IAW EMB 145 SRM 51-40-02-PR
00248 MID OMEGA BEAM GUSSET FROM FR 44 TO FR 52 HAS CORROSION. REMOVED AND REPLACED WITH NEW MID CABIN MID OMEGA BEAM GUSSET FROM FR 44 TO FR 52 IAW EMB 145 SRM 51-40-02-PR
00238 SERVICE DOOR INNER FRAME STRUCTURE ON RH SIDE MIDDLE OF DOOR IS GOUGED/SCRATCHED ON PREVIOUS REPAIR. CUTOUT AND INSTALLED FILLER AND DOUBLER ON SERVICE DOOR INNER FRAME STRUCTURE RH SIDE MIDDLE OF DOOR IAW EMB 145 SRM 52-43-01 STEP 7 FIG. 208. SEE PIEDMONT MAJOR EO# EO1-52-26-0235
00235 OMEGA BEAM GUSSET, MID, FROM FR 53 TO FR 57 HAS CORROSION. REMOVED AND REPLACED WITH NEW AFT WET AREA OMEGA BEAM GUSSET MID FROM FR 53 TO FR 57 IAW EMB 145 SRM 51-40-02-PR
00234 FLOOR SILL, RH, FROM FR 53 TO FR 59 HAS CORROSION. REMOVED AND REPLACED RH FLOOR SILL FROM FR 53 TO FR 59 PER EMB 145 SRM 51-40-02 STEP 2, B
00237 LH OMEGA BEAM FLANGE FROM FR 53 TO FR 59 HAS CORROSION. REMOVED CORROSION BY BLENDING ON AFT WET AREA, 1EA LH OMEGA BEAM FLANGE FROM FR 53 TO FR 59. FOUND WITHIN MAXIMUM ALLOWABLE LIMITS IAW EMB 145 53-24-10-AD.
RUDDER 2 LOWER SECTION INTERNAL BRACKET IS GOUGED. REMOVED AND REPLACED INTERNAL BRACKET ON RUDDER 2 LOWER SECTION PER SRM 51-40-02.
MID OMEGA BEAM GUSSET FROM FR 36 TO FR 38 HAS CORROSION. REMOVED AND REPLACED WITH NEW MID CABIN MID OMEGA BEAM GUSSET FROM FR 36 TO FR 38 IAW EMB 145 SRM 51-40-02-PR
00216 AFT CARGO DOOR MECHANISM BOX FRAME BRACKET ON FR 61 HAS A CRACK. REMOVED AND REPLACED WITH NEW AFT CARGO DOOR MECHANISM BOX FRAME BRACKET ON FR 61 IAW EMB 145 SRM 51-40-02 STEP 2, B AND C.
AFT CARGO DOOR MECHANISM BOX FRAME BRACKET ON FR 61 HAS A CRACK. REMOVED AND REPLACED WITH NEW AFT CARGO DOOR MECHANISM BOX FRAME BRACKET ON FR 61 IAW EMB 145 SRM 51-40-02 STEP 2, B AND C.
00236 MID OMEGA BEAM FLANGE FROM FR 53 TO FR 59 HAS CORROSION. REMOVED CORROSION BY BLENDING ON AFT WET AREA, 1EA MID OMEGA BEAM FLANGE FROM FR 53 TO FR 59. FOUND TO BE WITHIN MAXIMUM ALLOWABLE LIMITS IAW EMB 145 SRM 53-24-01-AD
RH FLOOR SILL FROM FR 36 TO FR 41 HAS CORROSION. REMOVED AND REPLACED WITH NEW RH FLOOR SILL FROM FR 36 TO FR 41 IAW EMB 145 SRM 51-40-02
LH OMEGA BEAM GUSSET FROM FR 29 TO FR 34 HAS CORROSION. REMOVED AND REPLACED MID CABIN L/H FLOOR SILL FROM FR 29 - FR 34 PER EMB 145 SRM 51-40-02-PR.
00300 CRACK IN THE RH WHEEL WELL WEB AT RIB 3. FABRICATED AND INSTALLED DOUBLER OVER CRACK IN THE RH WHEEL WELL WEB AT RIB 3 IAW EMB 145 SRM 53-23-12-RE SEE MINOR EO# EO1-05-26-0228
LEFT OMEGA BEAM GUSSET AT FR 22 HAS CORROSION. REMOVED AND REPLACED WITH NEW FWD WET AREA LH OMEGA BEAM GUSSET AT FR 22 IAW SRM 51-40-02-PR
MID OMEGA BEAM FLANGE FROM FR 23 TO FR 29 HAS CORROSION. BLENDED 6 QTY AREAS ON MID OMEGA BEAM FLANGE FROM FR 24 TO 29 TO REMOVE CORROSION. ALL 6 AREAS FOUND TO BE IN LIMITS IAW EMB 145 SRM 53-22-10-AD.
LH FLOOR SILL FROM FR 25 TO FR 29 HAS CORROSION. REMOVED AND REPLACED LH FLOOR SILL FROM FR 25 TO FR 29. REF SRM 51-40-02-PR SECTION 2 SOLID RIVETS
00126 SERVICE DOOR AFT LOWER FLOOR SILL AT FR 22 HAS CORROSION. REMOVED AND REPLACED WITH NEW FWD WET AREA SERVICE DOOR AFT LOWER FLOOR SILL AT FR 22 IAW EMB 145 SRM 51-40-02-PR
RIGHT FLOOR GUSSET AT FR 22 HAS CORROSION. REMOVED AND REPLACED RT FLOOR GUSSET AT FR 22 PER SRM 51-40-02 STEP 2C AND 3 B.
RIGHT FLOOR SILL DOUBLER AT FR 19 HAS CORROSION. REMOVED AND REPLACED WITH NEW RH FLOOR SILL AT FR 19 IAW SRM 51-40-02-PR STEP 2.B, 2.C AND 3.B.
ONE LT CROSSBEAM AT FR 20 HAS CORROSION. REMOVED AND REPLACED WITH NEW FWD WET AREA LT CROSSBEAM AT FR 20 IAW SRM 51-40-02-PR.
FLOOR GUSSET AT FR 18 LH OB AFT SECTION HAS CORROSION. RESTORED SURFACE PROTECTION TO FWD WET AREA FLOOR GUSSET AT FR 18 LH OB AFT BY APPLYING ALODINE, PRIMER, AND BLUE TOPCOAT PER CPM 51-21-04, PARAGRAPH 7 AND EMB 145 CPM 51-21-05 PARAGRAPH 8, STEP C, EMB 145 CPM 51-21-06, PARAGRAPH 8, STEP D (4), AND BULLETIN NUMBER 51-03.
SERVICE DOOR LOWER SURROUND STRUCTURE FLOOR SILL HAS CORROSION. REMOVED AND REPLACED WITH NEW FWD WET AREA SERVICE DOOR LOWER SURROUND STRUCTURE FLOOR SILL IAW SRM 51-40-02-PR STEP 2.B AND 4.B MAJOR EO# EO1-52-26-0237
LEFT OTBD FLOOR SILL AT FR 22 HAS CORROSION. REMOVED AND REPLACED WITH NEW FWD WET AREA LT OB FLOOR SILL AT FR 22 IAW SRM 51-40-02-PR.
LEFT OMEGA BEAM GUSSET FROM FR 25 TO FR 29 HAS CORROSION. REMOVED AND REPLACED WITH NEW FWD WET AREA LT OMEGA BEAM GUSSET FROM FR 25 TO FR 29 IAW SRM 51-40-02-PR.
1ST ORANGE EMERGENCY LIGHT INOPERATIVE. R & R THE LIGHT IAW AMM33-50-12.
GUST LOCK WOULD NOT DISENGAGE UPON ENTERING RUNWAY. FACT 27JAN25 09:56 PHL RR RELAY K0848 IAW AMM 20-13-02. NO FIX, RR GUST LOCK ACTUATOR IAW AMM 27-71-01. OPS CK GOOD AT THIS TIME. AC OK FOR SERVICE AT THIS TIME
STRONG ELECTRICAL SMELL COMING FROM AROUND L/H DC DISTRIBUTION BOX WITH NOTICABLE TEMP RISE NEAR BOX. R&R #3 FEEDER RELAY IRW AMM 24-31-05. OPS CHECK IRW AMM 24-31-00, OPS CHECK GOOD. OKAY FOR SERVICE AT THIS TIME.
AFTER TAKEOFF FUEL APPEAR TO ONLY BE PUMPING FROM RIGHT TANK. 700LB IMBALANCE NOTED. FACT 25MAY24 18:41 FAY PERFORMED FUEL LOW PRESS WARNING OPS CHECK IAW AMM 28-45-00-700-801-A & FUEL PANEL OPS CHECK IAW AMM 28-20-04-700-801-A BOTH OPS CHECKS GOOD. NO FUEL IMBALANCE AT THIS TIME. ACFT OK FOR SERVICE.
019241 LH ELEVATOR UPPER SKIN IS CRACKED AND BENT AT CENTER HINGE. PERFORMED DOUBLER REPAIR ON LH ELEVATOR UPPER SKIN AT CENTER HINGE IAW ETD2024-145-002671 AND EO1-55-24-0082.
E018700 NLG DRAG BRACE RH TRUNNION FITTING UPPER OTBD HOLE IS GOUGED. : REPAIRED GOUGED HOLE ON NLG DRAG BRACE RH TRUNNION FITTING UPPER OUTBOARD HOLE IAW PIEDMONT EO1-53-24-0113 AND ETD2024-145-002438REV A
E018701 NLG DRAG BRACE RH TRUNNION FITTING UPPER INBD HOLE IS GOUGED. : REPAIRED GOUGED HOLE ON NLG DRAG BRACE RH TRUNNION FITTING UPPER INBOARD HOLE IAW PIEDMONT EO1-53-24-0113 AND ETD2024-145-002438REV A.
E018661 RUDDER I LOWER CENTER HINGE FITTING UPPER DOUBLE HAT BUSHING HOLE WORN. REAMED RUDDER I LOWER CENTER HINGE FITTING UPPER DOUBLE HAT BUSHING HOLE TO REMOVE THE WORN AREA AND INSTALLED NEW FABRICATED HAT BUSHINGS AS REQUIRED IAW EMB145 SRM 55-00-02RE, ITEM 3, FIG 202 AND EO1-55-24-0075
E018662 RUDDER I UPPER CENTER HINGE FITTING LOWER HAT BUSHING HOLE WORN. REAMED RUDDER I UPPER CENTER HINGE FITTING LOWER HAT BUSHING HOLE TO REMOVE THE WORN AREAS AND INSTALLED OVERSIZE HAT BUSHING AS REQUIRED IAW EMB145 SRM 55-00-02RE, ITEM 3, FIG 202 AND EO1-55-24-0074
E018480 RH CABIN FLOOR SILL #2 CORRODED. RAR R/H CABIN FLOOR SILL #2 IAW EMB 145 SRM 51-40-02
E018479 LH CABIN FLOOR SILL #3 CORRODED. RAR LH CABIN FLOOR SILL #3 IAW EMB-145 SRM 51-40-02
E018429 LH OUTBD FLOOR SILL #2 CORRODED. REMOVED AND REPLACED THE LH OUTBD FLOOR SILL #2 IAW EMB 145 SRM 51-40-02, AND 51-20-03.
E018409 LH FLOOR OMEGA BEAM CRACKED AT FR22, BETWEEN STRG19L-18L. : ACCOMPLISHED PERMANENT REPAIR ON LH FLOOR OMEGA BEAM FR 22 ,BETWEEN STRG19L-18L IAW EMBRAER ETD2024-145-001945 AND PDT EO1-53-24-0078.
E018423 LH FLOOR STRUCTURE CROSSBEAM AT FR18 CORRODED. RAR L/H FLOOR STRUCTURE CROSSBEAM AT FR18 IAW EMB 145 SRM 51-40-02
E018410 LH FLOOR OMEGA BEAM CRACKED AT FR23, BETWEEN STRG19L-18L . PERFORMED REPAIR ON LH OMEGA BEAM AT FR 23 IAW EMB145 ETD2024-145-001946 REV A AND PDT EO1-53-24-0079.
E018428 LH OUTBD FLOOR SILL #1 CORRODED. RAR L/H OUTBD FLOOR SILL #1 IAW EMB 145 SRM 51-40-02
E018328 FR 72 CRACKED BETWEEN STRG 16L-17L UNDER FLOOR SILL. REMOVED CRACKED FR 72 FRAME SECTION BETWEEN STR 16L-17L UNDER FLOOR SILL, INSTALLED SERVICEABLE FRAME SECTION BETWEEN STR 17L-5L IAW EMB 145 SRM 51-40-02.
E018326 . RH CARGO FLOOR SILL FR68-FR71 HAS CORRSION AROUND SCREW HOLES. REMOVED AND REPLACED RH CARGO FLOOR SILL FR68-FR71 IAW EMB 145 SRM 51-40-02
E018325 RH CARGO FLOOR SILL FR71-FR73 HAS CORRSION AROUND SCREW HOLES. : RAR R/H CARGO FLOOR SILL FR71-FR73 IAW EMB 145 SRM 51-40-02
E018321 CARGO DOOR CUT-OUT LOWER FR65 SHEAR CLIP CORRODED. : RE-ACCOMPLISHED SHEAR CLIP REPAIR AT CARGO DOOR CUT-OUT LOWER FR65 IAW EMB 145 SRM 53-31-04RE.ITEM 4D.FIG. 212 AND EO1-53-24-0076.
E018330 FR 66 CRACKED BETWEEN STRG 16R-17R UNDER FLOOR SILL. REMOVED CRACKED FR 66 LOWER SECTION AND INSTALLED NEW SERVICEABLE FRAME 66 LOWER SECTION BETWEEN STRG14R-17L UNDER FLOOR SILL IAW EMB 145 SRM 51-40-02.
E017973 CORROSION AROUND SCREW HOLE ON SERVICE DOOR CUT-OUT AFT LOWER REINFORMENT STRUCTURE. BLENDED CORROSION AROUND SCREW HOLE ON SERVICE DOOR CUT-OUT AFT LOWER REINFORCEMENT STRUCTURE IAW EMB 145 SRM 51-10-03 AND ACCEPTED BLENDED AREA IAW PIEDMONT EO1-05-24-0123 AND ETD2024-145-001947
E017449 INTERNAL SIDE OF CARGO DOOR OUTER SKIN HAS 2 OVERLAPPING RIVET LINES NEAR THE UPPER END OF THE DOOR, WHERE EDGE DISTANCE IS NOT MAINTAINED, INCLUDING SOME RIVETS INSTALLED THRU EACH OTHER. REMOVED DAMAGED INTERNAL SIDE OF CARGO DOOR OUTER SKIN (UPPER OUTER FRAME), PREPPED AND INSTALLED SERVICEABLE INTERNAL SIDE OF CARGO DOOR OUTER SKIN (UPPER OUTER FRAME) IAW EMB 145 SRM 51-40-02.
E017313 THE LH WING SPAR 1 LOWER FLANGE IS CRACKED AT RIB 9. PERFORMED REPAIR ON LH SPAR I REPAIR PARTS AT RIB 9 IAW EO #EO1-57-24-0072 AND IAW EMB 145 SRM 57-20-05 ITEM 2.
E017309 3 RIVETS WITH POSSIBLE CRACKS ON FRAME 78 BETWEEN STRINGERS 3R-9R. : FURTHER INVESTIGATION OF 3 RIVETS WITH POSSIBLE CRACKS ON FR 78 BTW STR 3R-9R IAW EASI NDTM SHOWS ONLY 2 CRACKS. REPAIRED 1 CRACK ON FR 78 BTW STR 3R-4R AND 1 CRACK ON FR 78 BTW STR 8R-9R IAW PIEDMONT EO1-53-24-0083 AND EMB 145 SRM 53-32-01, ITEM 9, FIG 213.
BLEED 1 VALVE CLOSED MSG DISPLAYED IN FLT FOLLOWED BY PACK 1 VALVE CLOSED. REPLACED HOSE FROM HEPE FILTER TO #1 PACK, ALSO SLEEVE ON #1 PACK DUAL TEMP VALVE. GROUND RAN A/C PERFORMED AIR BLEED SYSTEM OPS CHECK. NO MESSAGE ON EICAS IAW AMM TSK 36-00-00-700-803-A. OK FOR SERVICE.
E2 REV DISAGREE ON EICAS ON TAKE OFF ROLL. #2 TR ICU AND HARNESS ASSY REPLACED AND COMPLIED WITH THRUST REVERSER RIGGING PROCEDURE. EVALUATION FLIGHT REQUIRED DUE TO "E2 REVERSE DISAGREE ON EICAS T/O ROLL. SBY EVALUATION FLIGHT SATISFACTORY.
ON TAKE OFF ROLL AFTER POWER LEVER FULLY ADVANCED FOR 2 SEC EICAS DISPLAYED E2 T/R DISAGREE. CREW REPORTED TR DID NOT DEPLOY. AND MESSAGE EXTINGUISHED AFTER THROTTLE PULLED BACK. CMC DISPLAYED E2 T/R ICU VALVE FAIL. MEL 20NOV23 23:06 CLT C32411 78-2 ENG 1(2) REV DISAGREE MESS. RE-ACTIVATED #2 T/R IAW AMM TASK 78-31-01-980-801-A. R/R'D #2 ICU IAW AMM 78-33-01-04. OPS CHECKS & LEAK CHECKS GOOD. NO RELATED EICAS OR CMC MESSAGES NOTED AT THIS TIME. CLEAR MEL 78-2.
E2 TR FAIL DISPLAYED WHEN PL ADVANCED. CW MX PROCEDURE MEL 16NOV23 12:31 CLT C32012 78-1 THRUST REVERSERS. REACTIVATED #2 TR IAW 78-31-01-780-801A A/C ARRIVED TO MX W/O RELATED CMC OR EICAS MSGS. CMC DWNLD DATED 11-17-23 SHOWED 4 OCC OF ENG2 TR ICU FAIL. C/W FIM 78-30-00-810-802A TO STEP 3. R&R'D #2 DAU IAW 31-41-01-04 OPS CHECK GOOD. OPS CHECK TR IAW 78-31-01-700-801A OPS CHECK GOOD CLEAR MEL
AFTER TAKE-OFF A BURNING SMELL WAS NOTED IN CABIN AND CIRCUIT BREAKER H-10 FOUND POPPED. (PASS SIGNS). FACT 27FEB23 10:39 PHL T/S AND FOUND STERILE LIGHT TO BE THE CAUSE OF CB H-10 TO POP. DID NOT DETECT ANY UNUSUAL ODORS WHEN RUNNING PACKS AND WITHOUT. REF SEQ.2 FOR STERILE LIGHT MEL.
PDIS 657 31-50 2852572 12FEB23 BOS CLOSE DURING TAKEOFF ROLL, SPOILERS OPENED WITH OPEN INDICATION AND AUDIBLE TRIM ANNUNCIATION WITH UNKNOWN MASTER WARNING FACT 12FEB23 22:19 BOS C/W OPS CHECK OF THE SPOILER SYS. AS PER AMM 22-63-01. OPS CHECK GOOD. A/C OK FOR SERVICE
RAPID CABIN DEPRESSURIZATION AT 12,000 FT. CA REPORT MANUAL PRESS CONT OPS NORMAL. R & R DIGITAL CONTROLLER OPS CHECK IN AUTO MODE GOOD. IAW AMM 21-31-01. (SHORT SIGN) R&R GROUND CONNECTION VALVE SPRING IAW AMM 21-22-04.
NOSE DOOR OPENED INFLIGHT UNCOMMANDED. TROUBLESHOT IRW EMB145 FIM 32-32-00810-802-A TO BLOCK 7. DETERMINED SOLENOID VALVE FAULTY. RB37833 08/06/22 R&R NLG DOOR SOLENOID VALVE IRW EMB 145 AMM 32-33-00 OPS & LEAK CHECK GOOD
PDIS 657 27-36 2473701 02APR22 ORD CLOSE RTO DUE TO EICAS MSG SPS 2 INOP AND SPS ADVANCE. FO PFD SHOWS AMBER AOA FACT 02APR22 22:19 ORD UPON ARRIVAL TO AIRCRAFT FOUND AOA VANES 1 AND 2 SPLIT. ALIGNED AOA PERFORMED STEP 1 OF FIM 27-36-00-810-802-A AND PERFORMED OPS CHECK IAW AMM 27-36-00-700-801-A FOUND TO BE TRANSITORY CONDITION OPS CHECK GOOD A/C OK FOR SERVICE.
PDIS 657 21-01 2583752 17FEB22 CLT ASSGN BAGG SMOKE EICAS MESSAGE APPEARED AFTER LANDING. FOLLOWED QRH AND USED BAG FIRE EXTINGUISHERS *AIRCRAFT CURRENTLY IN WORK. INSPECTED BAGGAGE COMPARTMENT AND BAGGAGE COMPARTMENT SMOKE DETECTORS NO DEFECTS NOTED. R&R BAGAGE COMPARTMENT FIRE BOTTLES IAW AMM 26-23-01 OPS CHECK GOOD. A/C OK FOR SERVICE. NO ABNORMAL EICAS MESSAGES PRESENT
FUSELAGE EXTERNAL SKIN IS CRACKED AROUND 2 FASTENERS ON FR 77 RH SIDE BELOW VERTICAL STAB. FABRICATED, PERFORMED CUTOUT. INSTALLED AND EDGE SEALED 1 EA. SKIN BUSHING ON FR. 77 RH SIDE IAW EMB 145 SRM 53-32-01 ITEM #9 FIG. 213 SHEET 2 SRM 51-20-01 AND PIEDMONT EO1-53-21-0243.
FUSELAGE EXTERNAL SKIN IS CRACKED AROUND 2 FASTENERS ON FR 77 LH SIDE BELOW VERTICAL STAB. FABRICATED, PERFORMED CUTOUTS, AND INSTALLED EDGE SEALED 2 EA SKIN BUSHINGS ON FR 77 LH SIDE IAW EMB 145SRM 53-32-01 ITEM #9 FIG 213 SHEET 2, 51-20-01 AND EO1-53-21-0242.
FUSELAGE EXTERNAL SKIN IS CRACKED AROUND 2 FASTENERS ON FR 79 RH SIDE BELOW VERTICAL STAB. INSTALLED AND EDGE SEALED 2 EA SKIN BUSHINGS ON FR 79 RH SIDE IAW EMB 145 SRM 53-32-01, ITEM 9, FIG. 213, SHEET 2, EMB 145 SRM 51-20-01, AND PIEDMONT EO1-53-21-0243.
RH ELEVATOR UPPER SURFACE SKIN EDGE ABOVE SERVO TAB CONTROL LEVER HINGE DAMAGED. FABRICATED, INSTALLED AND EDGE SEALED REPAIR DOUBLER ON RH ELEVATOR UPPER SKIN EDGE AT SERVO TAB CONTROL LEVER HINGE CUTOUT IAW EMB 145 SRM 55-20-01, ITEM 3, REPAIR A, FIG. 229 AND EO1-55-21-0232.
CARGO DOOR CUT OUT LOWER CENTER SILL FR 65 AND FR 68 CONNECTING STRAPS FOUND TO BE GOUGED AND HAVE ELONGATED HOLES. INSTALLED DOUBLER P/N 145-25412-005 AT FR 65 AND DOUBLER P/N 145- 25412-001 AT FR 68 IAW EMB 145 SRM 51-40-02.
L/H LOWER BANANA PANEL CORRODED. REMOVED AND REPLACED WITH NEW AND SERVICEABLE L/H LOWER BANANA PANEL IAW EMB145 SRM 51-40-02.
CARGO LH FWD FLOOR SILL IS CORRODED AT FWD SCREW HOLE IN LAVATORY. REMOVED AND REPLACED FWD L/H SILL IAW EMB 145 SRM 51-40-02.
PAX DOOR ENTRANCE FWD AND AFT FLOOR BOARD SUPPORT BRACKETS ARE CORRODED AROUND SCREW HOLES. REMOVED AND REPLACED PAX DOOR CUTOUT FWD AND AFT FLOOR SUPPORTS IAW EMB-145 SRM 51-40-02.
CROSSBEAM BTW FR 24-25 IS CORRODED. REMOVED AND REPLACED CROSSBEAM BTW FR 24-25 IAW EMB 145 SRM 51-40-02 AND 51-20-01.
CENTER OMEGA BEAM GUSSET #1 IS PITTED. REMOVED AND REPLACED CABIN CENTER OMEGA BEAM GUSSET #1 IAW EMB-145 SRM 51-40-02.
CENTER OMEGA BEAM GUSSET #2 IS PITTED. REMOVED AND INSTALLED SERVICEABLE CENTER OMEGA BEAM GUSSET #2 IAW EMB145 SRM 51-40-02.
COCKPIT LH BULKHEAD OTBD GUIDE PIN HOLE DOUBLER IS CHAFED. REPAIRED LH COCKPIT OTBD GUIDE PIN HOLE IAW EMB 145 SRM 53-21-02 RE, ITEM 4, FIGURE 204 AND PIEDMONT EO1-53-21-0231.
LH OUTBD FLOOR SILL #4 IS PITTED. REMOVED AND INSTALLED NEW AND SERVICEABLE LH OUTBD FLOOR SILL #4 IAW EMB145 SRM 51-40-02.
RH OUTBD SEAT TRACK SUPPORT IS CORRODED AT FR 46. PERFORMED REPAIR OF SEAT TRACK SUPPORT AT FR 46 IAW EMB 145 SRM 53-00-11 REPAIR TYPE C.
RH OUTBD FLOOR SILL #4 IS PITTED. REMOVED AND REPLACED RH OUTBD FLOOR SILL #4 IAW EMB 145 SRM 51-40-02.
RH OUTBD FLOOR SILL #3 IS PITTED. REMOVED AND REPLACED RH CABIN FLOOR SILL #3 IAW EMB-145 SRM 51-40-02.
CARGO DOOR CUTOUT LWR SILL IS CORRODED IN MULTIPLE AREAS. REMOVED AND INSTALLED SERVICEABLE CARGO DOOR CUT OUT LOWER CENTER SILL IAW EMB 145 SRM 51-40-02.
LAV CENTER FLOOR GUSSET IS CORRODED AT AFT SCREW HOLE.(PREVIOUS BLEND) REMOVED CORRODED AND INSTALLED NEW LAV CENTER FLOOR GUSSET IAW EMB 145 SRM 51-40-02.
LAV RH CENTER FLOOR GUSSET IS CORRODED AROUND 3 SCREW HOLES. REMOVED CORRODED CENTER RH LAV GUSSET AND INSTALLED SERVICEABLE GUSSET IAW EMB 145 SRM 51-40-02.
LH OUTBD FLOOR SILL #2 IS PITTED. REMOVED AND REPLACED LH OUTBD FLOOR SILL #2 IAW EMB145 SRM 51-40-02.
CENTER OMEGA BEAM GUSSET #3 IS PITTED. REMOVED AND REPLACED CENTER OMEGA BEAM GUSSET #3 IAW EMB145 SRM 51-40-02.
LH OUTBD FLOOR SILL #3 IS PITTED. REMOVED AND INSTALLED NEW LH OUTBD FLOOR SILL #3 IAW EMB 145 SRM 51-40-02.
RH OUTBD FLOOR SILL #1 IS PITTED. REMOVED AND REPLACED RH #1 OUTBD FLOOR SILL AS REQUIRED IAW EMB 145 SRM 51-40-02.
LAV LH CENTER FLOOR GUSSET IS CORRODED AT FWD AND AFT SCREW HOLES. REMOVED CORRODED AND INSTALLED NEW L/H LAV CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-02.
RH OUTBOARD FLOOR SILL #2 IS PITTED. REMOVED AND INSTALLED NEW SERVICEABLE OUTBOARD FLOOR SILL #2 IAW EMB145 SRM 51-40-02.
RH WING RIB 21 IS CRACKED INSIDE PANEL 651CB. INSTALLED DOUBLER, FILLER AND SHIM FOR REPAIR OF RH WING RIB 21 INSIDE PANEL 651CB IAW EMB145 SRM 57-20-07RE, ITEM 4, FIG 203 AND PIEDMONT EO1-57-21-0233.
MAIN CABIN DOOR WILL NOT OPEN FROM THE INSIDE. FOUND PAX DOOR HANDLE INCORRECTLY POSITIONED. REMOVED HANDLE AND RE INSTALLED IN CORRECT POSITION PER AMM 52-18-05. OPS CHECK GOOD. OK FOR SERVICE
LAV SMOKE EICAS MSG DISPLAYED IN FLT. PERFORMED INSPECTION OF LAV SMOKE DETECTOR. NO DEFECTS NOTED. C/W LAV SMOKE DETECTION SYSTEM IAW 26-14-00. SYS OPS NORMAL. OK FOR SERVICE. SUSPECT VAPING IN LAV
RH OVER WING EMERGENCY LIGHT INOP....FIX: R&RD RH OVER WING EMERGENCY LIGHT IAW 33-50-10-000/400-801-A.OPS CHECK GOOD
MDIS 657 72-13 2081341 02NOV19 CLT ASSGN OIL LEAK #2 ENG AFT END NEAR DIFFUSER. FIRE IN EXHAU ST FOR 1 TO 2 MINUTES 26631 00 EK ENGINE CHANGE IS CURRENTLY IN PROGRESS FIX: R&RD #2 ENGINE IAW W/C 71-00-00.
R/H AFT EMERGENCY EGRESS LIGHT INOP....FIX: REMOVED LENS REPLACED BULB, INSTALLED LENS
PDIS 657 31-50 2067831 11SEP19 PHL ASSGN CAPT CAUTION LIGHT DOES NOT EXTINGUISH. MEL 11SEP19 21:28 PHL C25422 31-7-1 MASTER CAUTION LIGHTS.
FA/PASSENGERS CALLED COCKPIT FOR BURNING SMELL IN CABIN ON TAXI. NO SMOKE NOTED. CAPTAIN AND FO SMELLED BURNING IN FLT DECK, NO SMOKE NOTED. RAN QRH PROCEDURE, GOT A/C IN SAFE STATE. RAN BOTH PACKS OF APU AND ENGINE BLEEDS, CHECKED FOR SMELLS AND SMOKE, NONE NOTED. TAXIRD A/C AND CHECKED BRAKES AND STEERING FOR DEFECTS, NONE NOTED, OK FOR SERVICE
657 26-15 1935221 10APR19 ROC CLOSE BAGBAY EXT. BOTTLE INOP EICAS MESSAGE DISPLAYED. DISCOVERED HALON LEAKING IN BAGBAY. 10APR19 16:11 ROC C10009 26-8 BAG BAY FIRE EXTINGUISHER FACT 11APR19 02:37 PHL R&R BAGGAGE BAY HIGH RATE AND METERING FIRE BOTTLES. ALSO TWO-WAY CHECK VALVE. C/W WORCARD 26-23-01. ON RON WORK PACKET DATED 4/10/19. CLEAR MEL 26-8
PDIS 657 21-11 1915522 16DEC18 PHL CLOSE AFTER TAKEOFF BLD 1 LEAK EICAS MSG ALONG WITH RED INSCRIPTION ON BLEED SWITCH. AFTER QRH, MESSAGES EXTINGUISHED. HISTORY: YES FACT 16DEC18 14:35 PHL INSPECTED ENGINE 1 BLEED VALVE AND FOUND LOOSE BLEED CLAMP CONNECTING VALVE TO Y DUCT. TIGHTENED CLAMP AS REQUIRED PERFORMED ENNGINE BLEED LEAK CHECK IAW EMB 145 AMM 36-00-00-710-002-A. NO LEAKS NOTED OPS CHECK GOOD AT THIS TIME OK FOR SERVICE.
RH EXTERNAL FUSELAGE SKIN CRACKED AROUND 2 RIVETS FR 78-C/A-RH EXTERNAL FUSELAGE SKIN CRACKED AROUND 2 RIVETS FR 78 REPAIRED IAW ERS-EM-53MR-3518
#4 FLOOR EMERGENCY LITE STRIP HAS BROKEN WIRE-C/A-RAR #4 EMERGENCY LITE STRIP IAW EMB 145 AMM 33-50-12 OCK GOOD
FR20 FLOOR PROXIMITY LIGHT #1 WIRES BROKEN CONNECTORS-C/A-REPAIRED FR 20 FLOOR PROXIMITY LIGHT #1 WIRES IAW EMB 145 SWPM 20-21-00. FOUND DURING OPEN UP.
EMERGENCY LIGHT STRIP #8 CONNECTOR AT FLOOR PANEL 261BF MISSING (AIRCRAFT SIDE)-C/A-INSTALLED MISSING CONNECTORS AT FLOOR PANEL 261BF (AIRCRAFT SIDE) SP9212 WIRE W192-8832-22 AND SP9213 WIRE W192-8833-22 IAW EMB 145 SWPM 20-50-00
CENTER SERVICE DOOR SILL CORRODED AROUND FWD AND AFT NUTPLATE HOLES-C/A-REMOVED AND REPLACED SERVICE DOOR CUTOUT LOWER CENTER SILL IAW EMB145 SRM 51-40-02
FRAME 73 IS CRACKED BETWEEN STRINGERS 16R - 17R-C/A-REMOVED AND REPLACED FRAME 73 (LOWER FRAME) IAW EMB 145 SRM 51-40-02
LH OMEGA BEAM IS CORRODED AT CROSSBEAM FR-29-C/A-REPAIRED LH OMEGA BEAM CORROSION AT FRAME 29 IAW ERS-EM-53MR-3510.
NUTPLATE ON RUDDER II LH SIDE ELONGATED HOLES-C/A-ACCOMPLISHED PERMANENT REPAIR OF RUDDER II BOTTOM LH SIDE SKIN IAW ERS-EM-55MR-717
BAGGAGE DOOR EXTERNAL SKIN IS CRACKED NEAR HANDLE-C/A-PERFORMED PERMANENT REPAIR ON BAGGAGE DOOR IAW ENVOY ERS-EM-52MR-928
CORROSION ON BAGGAGE DOOR LOWER INTERNAL PROFILE BRACKET AT PREVIOUS REPAIR-C/A-REMOVED AND REPLACED BAGGAGE DOOR LOWER PROFILE IAW EMB 145 SRM 51-40-02
RH ENGINE PYLON FWD LOWER YOKE CRACKED-C/A-REMOVED AND REPLACED RH FWD LOWER YOKE IAW EO EM-54MR-698
RH ELEVATOR SPRING TAB CENTER HINGE FITTING WORN-C/A-REMOVED AND REPLACED RH ELEVATOR SPRING TAB CENTER HINGE SUPPORT IAW EMB 145 AMM 55-22-01 AND ENVOY ETN-EM-55-086
R/H EXTERNAL FUSELAGE SKIN CRACKED AROUND RIVET FR-77 MARKED-C/A-COMPLETE:REPAIRED SKIN CRACK AT 1 LOCATION ON T HE RH EXTERNAL FUSELAGE SKIN AT FR77 IAW EMB 145 SRM 53-32-01 (ITEM 9) AND ETN-EM-53-194R1 AND ETN-EM-53-276R2. SEE TURNOVER FOR DETAILS
PILOTS ESCAPE ROPE FRAYED.-C/A-COMPLETE:REMOVED AND REPLACED PILOTS ESCAPE ROPE IAW EMB 145 AMM 25-60-07.
UPON GATE ARRIVAL UNABLE TO OPEN MAIN PAX DOOR FROM INSIDE. HAD TO BE OPEN FROM OUTSIDE.-C/A-RE SECURED DOOR HANDLE ATTACH BOLT AN OPERATED DOOR SEVERAL TIMES FROM INSIDE. IAW EMB145 AMM52-18-05. REF AML LOG 4442071 ITEM 2 FOR FUNCTIONAL TEST. PERFORMED MAIN CABIN DOOR FUNCTIONAL TEST IAW EMB 145 AMM 52-18-06. FUNCTIONAL CHECK GOOD.
EMERGENCY LIGHT ON SERVICE DOOR INOP-C/A-COMPLETE:REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT BULB IAW EMB 145 AMM 33-50-09. ILLUMINATION CHECK GOOD.
R/H EXTERNAL FUSELAGE SKIN CRACKED AROUND RIVET FR-79 MARKED-C/A-COMPLETE:REPAIRED SKIN CRACK AT 1 LOCATION ON THE RH EXTERNAL FUSELAGE SKIN AT FR79 IAW EMB 145 SRM 53-32-01 (ITEM 9) AND ETN-EM-53-194R1 AND ETN-EM-53-276R2. SEE TURNOVER FOR DETAILS
LH PASSENGER ESCAPE HATCH LINING LOWER EMERGENCY LIGHT INOP.-C/A-COMPLETE:REMOVED CONNECTED AND REINSTALED LH PASSENGER ESCAPE HATCH LINING LOWER EMERGENCY LIGHT OP CK CW IAW EMB 145 AMM 33-50-13
CLIMBING THROUGH FL220, CREW RECEIVED PACK 1 & 2 FAIL MESSAGES AND NOTED THE CABIN ALTITUDE WAS 10,000 FT. AND CLIMBING. DECLARED AN EMERGENCY, BEGAN A DESCENT. CREW WAS ABLE TO RESET THE PACKS AND PRESSURIZATION RETURNED TO NORMAL. CREW CONTINUED TO DESTINATION. NO LEAKS NOTED DURING THE FLIGHT. PERFORMED THE PRSSURIZATION OF THE AIRRAFT ON THE GROUND IAW AMM 21-31-00. OPS CHECKED GOOD. AIRCRAFT HELD ITS PRESSURE AT 3.7 DELTA P. PACKS OPERATED NORMALLY. AIRCRAFT IS OK FOR SERVICE.
ROW 16 CEILING EMERGENCY LIGHT WAS INOPERATIVE. R & R THE LAMP IAW AMM 33-50-08. OPS CHECKED GOOD.
FWD FA FLASHLIGHT INOPERATIVE. R & R THE FWD FA FLASHLIGHT, OPS CHECKED GOOD IAW AMM 33-50-16.
MAIN ENTRY DOOR UNABLE TO OPEN WITH DOOR HANDLE, DOOR HANDLE NOT SECURE. SECURED THE DOOR HANDLE IAW AMM 52-10-01, OPS CHECKED GOOD, NO DEFECT NOTED.
BLEED 1 LEAK DURING DEPARTURE, RAN QRH, MESSAGE DID NOT EXTINGUISH AND RETURNED TO DEPARTURE. EMERGENCY DECLARED. PERFORMED OPC OF E1 BLEED AIR SYSTEM AS PER EMB145 AMM 36-00-00. OPS CHECKED GOOD. PERFORMED LEAKAGE TEST OF LT AIR BLEED SYSTEM DUCTS IAW AMM 36-00-00. LEAK CHECKED GOOD. PERFORMED AN OPS CHECK IAW AMM 36-11-05, OPS CHECKED GOOD. PERFORMED OPS CHECK OF BLEED 1 TEMP SENSOR IAW AMM 36-11-05, OPS CHECKED GOOD. INSTALLED BLEED DUCT AT JOINT 17 IAW AMM 36-11-10. REPLACED BLEED DUCT CLAMP ON ENGINE 1 BLEED VALVE IAW AMM 36-11-05. REPOSITIONED CLAMPS AND DUCTS BETWEEN PRECOOLER AND Y-DUCT IN THE LT PYLON IAW AMM 36-11-09. OPS AND LEAK CHECKED GOOD. REMOVED AND REPLACED LT PYLON HARNESS W421 IAW SWPM 20-50-00 AND SWPM 20-13-02, OPS CHECKED GOOD IAW AMM 36-20-02. REMOVED AND REPLACED CHECK VALVE GASKET AND OPS CHECKED GOOD IAW AMM 36-11-01.
DURING PS-1 FOUND EMER PATH LIGHTING STRIP BETWEEN ROWS 5 AND 7 INOP. R&R FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12, OPS CHECK GOOD.
EMERGENCY LIGHT AT ROW 6 - 7A INOPERATIVE.
EMERGENCY LIGHTS AT MAIN ENTRANCE AND GALLEY INOPERATIVE. R & R THE BULBS IAW AMM 33-50-06, AND 33-50-09. OPS CHECKED GOOD.
RIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE EXTERNAL EMERGENCY LIGHT ASSY IAW AMM 33-50-10. OPS CHECKED GOOD.
AFTER SUCCESSFUL ICE TEST, THE NR 1 ENGINE BLEED LEAK ON EICAS, WENT OUT AFTER DESELECTED THE BLEED SWITCH. REMOVED AND REPLACED O-RINGS AT JOINT NR 1 AND 28. REPLACED THE BLEED DUCT IN AVIONICS COMPARTMENT ALL WORK PERFORMED IAW AMM 36-11-09 AND LEAK AND OPS CHECKED GOOD IAW AMM 36-00-00.
NR 1 BLEED LEAK WARNING DURING FLIGHT. RAN PROCEDURE, MESSAGE EXTINGUISHED. REMOVED AND REPLACED BLEED O-RINGS IN THE AFT ELECTRONIC COMPARTMENT IAW AMM 36-11-10. OPS CHECKED GOOD IAW AMM 36-00-00.
THE LAV BUCKET IS CORRODED. ACCOMPLISHED REPAIR TO LAV BUCKET IAW ERS-EM-53MR-2566.
PASSENGER DOOR SKIN LOWER AFT CORNER GOUGED ON INTERNAL SIDE. ACCOMPLISHED REPAIR OF PASSENGER DOOR SKIN LOWER AFT CORNER INTERNAL SIDE IAW ERS-EM-52MR-705. SEE TASKS AND WIPS FOR DETAILS.
CARGO DOOR FWD FRAME CORRODED AT 3 NUTPLATE HOLES. ACCOMPLISHED REPAIR TO CARGO DOOR FWD FRAME AT 3 NUTPLATE HOLES IAW ENVOY ERS-EM-52MR-704.
FR 65 SHEAR CLIP CORRODED STGR 16L-17L AT LOWER CARGO DOOR GUIDE STRIKER PLATE. REPAIRED SHEAR CLIP SECTION AT FRAME 65 BETWEEN STRINGERS 16L-17L AT LOWER CARGO DOOR GUIDE STRIKER PLATE IAW SRM 53-31-04.
IN COCKPIT, RT LATERAL BRACKET IS CRACKED ADJACENT TO THE RT CEILING SPEAKER. ACCOMPLISHED REPAIR OF RT LATERAL BRACKET ADJACENT TO THE RT CEILING SPEAKER IAW SRM 51-40-02, 51-20-03
LT RFII SKIN DENT BTW FR 78-79 AND STR 5L-6L. ACCOMPLISHED PERMANENT REPAIR DOUBLER FOR LT RFII SKIN DENT BTW FR 78-79 AND STR 5L-6L IAW ERS-EM-53MR-2572.
RT UPPER FUSELAGE SKIN CRACKED AFT OF FRAME 75 AND ABOVE STRINGER 2R, CRACK IS APPROX 3/8" LONG ENDS MARKED. PERFORMED REPAIR TO RT UPPER FUSELAGE SKIN AFT OF FR 75 AND ABOVE STRINGER 2R IAW SRM 53-31-01 AND ETN-EM-51-40-02.
LT PYLON LOWER FWD ENGINE YOKE CRACKED AFT SIDE. REMOVED AND INSTALLED NEW LT PYLON LOWER FWD ENGINE YOKE IAW EO EM-54MR-386R1.
LT ENGINE AFT LOWER MOUNT FLEX CRACKED BEYOND LIMITS. REMOVED AND REPLACED LT ENGINE AFT LOWER ENGINE MOUNT IAW AMM 71-20-00.
LT ENGINE AFT UPPER MOUNT FLEX CRACKED BEYOND LIMITS. REMOVED AND REPLACED LT ENGINE AFT UPPER ENGINE MOUNT IAW AMM 71-20-00.
RT TR S HOOK ACTUATOR TO DOG BONE LINK HARDWARE INSIDE 426QL CORRODED. REMOVED HARDWARE FOR RT TR S HOOK ACTUATOR TO DOG BONE LINK INSIDE 426QL, CLEANED CORROSION, AND REINSTALLED HARDWARE IAW AMM 78-32-02 STEPS 2 J (2) AND 3 I (3) AND CPM 51-14-04. OPERATIONAL CHECK OF THE THRUST REVERSERS
AFT CABIN FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED THE FLASHLIGHT . OPS CHECKED GOOD.
WHEN GEAR SELECTED DOWN ON APPROCH, RECEIVED AN EICAS MESSAGE FOR BRAKE INBD INOPERATIVE. THE BRAKING ACTION ON THIS RUNWAY WAS SIGNIFICANTLY REDUCED. PERFORMED OPS CHECK OF THE MAIN BRAKE SYSTEM IAW AMM 32-41-00. NO DEFECT NOTED NO MESSAGES NOTED. OK FOR SERVICE. REMOVED AND REPLACED BCU IAW AMM 32-41-02 OPS CHECKED GOOD
PACK 2 VALVE CLOSED TWICE DURING CLIMBOUT. TRANSFERED DISCREPANCY TO ITEM NR 3, THIS LOG PAGE. R & R OUTLET DUCT AND SLEEVE IAW AMM-21-51-02. OPS CHECK GOOD.
DURING LANDING GEAR EXTENSION, IT SOUNDED LIKE SIGNIFICANT DEBRIS CAME LOOSE IN THE NOSE WHEEL WELL. WE DID LOW FLY BY, TOWER INDICATED EVERYTHING APPEARED NORMAL. WE DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. FOUND NLG LANDING LIGHT ASSY BROKEN. R & R NLG LANDING LIGHT ASSY IAW AMM 33-41-02. OPS CHECK GOOD.
NR 2 WINDSHIELD HEAT FAIL, NR 2 VHF COM INOPERATIVE. FLIGHT CREW PLACARDED, NR 2 WINDSHIELD HEAT. M PROCEEDURES CW MEL 30-24. AUTHORIZATION 060788DM-C. FLIGHT CREW PLACARDED NR 2 VHF. MEL 23-02. AUTHORIZATION 060790D-C. R & R NR 2 WINDSHIELD HEAT CONTROLLER IAW AMM 30-42-01. OPS GOOD AT THIS TIME, ALL MAINTENANCE ACTIONS COMPLIED WITH, MEL RESTORED.
ENTER ICING CONDITIONS AT FL290, ANTI-ICE SYS TURNED ON AUTOMATICALLY. EICAS PRESENTED WING ANTI-ICE FAIL MSG 30 SECONDS AFTERWARDS. DECLARED EMERGENCY, INBD & GRR DUE WING ANTI-ICE FAIL. LANDED SAFE. PERFORMED OPERATIONAL TEST OF THE WING ANTI-ICE SYS IAW AMM 30-00-00. OPERATIONS CHECK GOOD.
RIGHT AFT OVERWING EMER LIGHT INOPERATIVE. R & R THE RT AFT OVERWING EMER LIGHT LAMP IAW AMM 33-50-07-000-801-A & 33-50-07-400-801-A. OPERATIONS CHECKED GOOD.
MAIN DOOR OVERHEAD EMER LIGHT INOPERATIVE. REPLACED MAIN DOOR OVERHEAD EMER LIGHT IAW AMM 33-26-05-000-801-A & 33-26-05-400-801-A.
CAPTAINS SIDE FLASHLIGHT WORKS ONLY WHEN YOU SHAKE OR TAP ON IT. R & R A NEW FLASHLIGHT IAW 33-50-16.
NUMBER 1 HYD QTY LOW ADVISORY ON EICAS UPON TAKEOFF & LG RETRACTION INDICATION IN THE AMBER. FOUND HYD 1 LOW & HYD 2 TO BE HIGH, INSPECTED HYD SYS 1 FOR LEAKS, NO LEAKS NOTED. R & R 1 & 4 BRAKE SHUTTLE VLVS IAW AMM 32-49-03. OPERATIONS CHECKED GOOD & LEAK CHECKED GOOD. REF AML 3994137 ITEM 1 FOR FURTHER CORRECTIVE ACTION. SERVICED HYD SYS 1 IAW AMM-12-13-01. SHUTTLE VLV PN 211-118 & SN 5164 NR 4.
MAIN CABIN DOOR INNER HANDLE HARD TO OPERATE. PERFORMED LUBRICATION OF MAIN DOOR FRAME ROLLERS IAW AMM 53-21-02. OPERATIONS CHECKED SATISFACTORY IAW AMM 52-18-00.
THERE WAS A FLASH & POP WITH BURNING SMELL UNDER CAPTAINS PEDESTAL. CB C 20 POPPED, LOSS OF ALL ASSOCIATED ELEC. PERFORMED WIRE REPAIR ON WIRE W101-3438-24, AT MFD-1 PEDESTAL LIGHTING PANEL, WIRE W101-0837 20, PEDESTAL CONT LT, PEDESTAL LIGHTING PANEL & W101-2644-20, PEDESTAL LIGHTING PANEL, P7169. OPERATIONS CHECKED GOOD IAW SWPM 20-20-00 & AMM 33-11-00.
RIGHT EXTERNAL OVERWING EMER LIGHT INOPERATIVE. R & R RT EXTERNAL OVERWING EMER LIGHT LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A. OPERATIONS CHECKED GOOD.
RIGHT AFT OVERWING EMER LIGHT INOPERATIVE. FOUND A LOOSE ELEC CONNECTOR ON RT AFT OVERWING EMER LIGHT. TIGHTENED ELEC CONNECTOR IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.
RIGHT OVERWING EMER LIGHT INOPERATIVE. R & R RT OVERWING EMER LIGHT LAMP IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.
NUMBER 2 FLOOR PROXIMITY LIGHT INOPERATIVE. R & R NR 2 BATTERY POWER SUPPLY & BATTERY PACK IAW AMM 33-50-04.
MAIN DOOR EMER LIGHT DOES NOT COME ON. R & R NR 1 BATTERY POWER SUPPLY & BATTERY PACK IAW AMM 33-50-04. OPERATIONS CHECKED GOOD.
FLOOR PROXIMITY LIGHT WIRE LT NR 1 HAS BROKEN WIRES. REPLACED FLOOR PROXIMITY LIGHT STRIP NR 1 IAW AMM 33-50-12. FOUND DURING ACFT OPEN UP.
FRAME 75 SKIN CRACK ABOVE STRINGER 2L AREA. PERFORMED PERMANENT REPAIR OF FRAME 75 SKIN CRACK ABOVE STRINGER 2L AREA IAW ERS-EM-53MR-929.
NUMBER 1 EMER LIGHT STRIP EXTRUSION DAMAGED. R & R NR 1 EMER LIGHT STRIP EXTRUSION IAW AMM 33-50-12.
STRONG SULFUR SMELL EN ROUTE, MID CABIN. R & R ROW 4A PSU LIGHT BALLAST IAW AMM 33-21-03. NO STRONG SMELL NOTED.
DURING HIGH SPEED TAXI & ABORT 80 - 90 KNOTS, WE GOT A TAKEOFF CONFIG ON EICAS & MASTER WARNING. SPOILERS INDICATED OPEN ON EICAS. COMPLIED WITH OPERATIONS CHECK FOR SPOILER SYS IAW ETM-27-165. COMPLIED WITH CONFIG WITH WARNING. OPERATIONS CHECKED GOOD IAW AMM 27-53-00.
AFTER GEAR RETRACTION WIND NOISE FROM FRONT GEAR, SUSPECT GEAR DOORS OPENED. GEAR CYCLE UNSUCCESSFUL AFTER 3 ATTEMPTS. R & R NLG SEQUENCE PROX SWITCH & PERFORMED RETRACTION & EXTENSION IAW AMM 32-30-00. PER REQUEST OF REPEAT DESK R & R NLG DOOR LT & RT ACTUATOR IAW AMM 32-33-03. OPERATIONS CHECKED GOOD. NLG DOOR ACTUATOR RT PN 21180100401, SN 1765. PROXIMITY NLG 6 PN 8-527-01 SN A28744.
MAIN CABIN DOOR DIFFICULT TO OPEN & CLOSE. FLIGHT ATTENDANT REPORTS HANDLE IS BINDING UP. SERVICED MAIN DOOR ROLLERS IAW AMM 53-21-02. NO FURTHER DEFECTS NOTED AT THIS TIME.
FLIGHT ATTENDANT FLASHLIGHT HOLDER ASSEMBLY WILL NOT HOLD FLASHLIGHT SECURELY. R & R FLIGHT ATTENDANT FWD FLASHLIGHT ASSEMBLY & OPERATIONS CHECKED IAW AMM 25-60-03 SATISFACTORY.
FLIGHT ATTENDANT REPORTS MAIN CABIN DOOR HARD TO OPEN. TIGHTEN INTERNAL HANDLE BOX BOLTS IAW ETN-EM-52-052. DOOR OPERATIONS CHECKED GOOD IAW MM 52-18-00.
RIGHT INTERIOR OVERWING EXIT SIGN INOPERATIVE. R & R EMERGENCY LIGHT DC & AC INVERTER NR 5 IAW AMM 33-50-11, OPERATIONS CHECKED GOOD.
EXIT EMERGENCY LIGHT AT ROW 3 INOPERATIVE. R & R EXIT EMERGENCY LIGHT AT ROW 3, OPERATIONS CHECKED BAD IAW AMM 33-50-13.
FOLLOWING EMERGENCY LIGHT INOPERATIVE. BOTH OVERWING, AFT FLOOR & AFT 2 CEILING LIGHTS. R & R NR 4 BATTERY POWER SUPPLY IAW AMM-33-50-04. OPERATIONS CHECKED GOOD.
EMERGENCY LIGHT FLOOR STRIPS PUT IN BACKWARDS. REPOSITIONED EMERGENCY FLOOR LIGHTING STRIPS IAW AMM 33-50-12, OPERATIONS CHECKED GOOD.
FLIGHT ATTENDANT AFT FLASHLIGHT MISSING. INSTALLED AFT F/A FLASHLIGHT AS PER CMM 25-60-11 MEL RESTORED
ELECTRICAL EMERGENCY ABNORMAL EICAS MESSAGE CAME ON CLIMBING THRU 30000 FT, ALONG WITH EMERGENCY LIGHTS NOT ARMED, EMERGENCY LIGHTS ILLUMINATED IN THE CABIN. MESSAGE STAYED ON AFTER 30 SECONDS THEN DISAPPEARED. TRANSFERRED TO NRWC 657-ORD-01540. R & R ELEC CONTROL PANEL IAW AMM 24-00-01, OPERATIONS CHECKED GOOD IAW NRWC 657-ORD-01540.
MAIN CABIN DOOR HARD TO OPEN. CHECKED AND LUB MAIN DOOR FRAME ROLLERS IAW AMM 53-21-02, OPS CK DOOR IAW AMM 52-10-01, SATISFACTORY.
MAIN PAX DOOR VERY DIFFICULT TO CLOSE AND OPEN. LUBED MAIN DOOR ROLLERS AND OPERATED DOOR NUMEROUS TIMES WITH NO ISSUES IAW MM 52-10-00.
ON FLIGHT 3538 THE FLIGHT ATTENDANT REPORTED THAT AFTER LANDING A BURNING ODOR WAS NOTICE IN THE CABIN. THE COCKPIT CREW NOTICED THE ODOR IN THE COCKPIT AS WELL. THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED ENGINE ODOR EVENT TROUBLESHOOTING IAW-ETN-EM-72-034. NO ODOR FOUND. THE AIRCRAFT WAS RETURNED TO SERVICE.
DURING B INSPECTION FOUND THE RIGHT EXTERIOR OVERWING EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LIGHT BULB IAW EMB AMM 33-50-07-000-801-A AND INSTALLED NEW BULB IAW EMB AMM 33-50-10-400-801-A. THE OPERATIONAL CHECK WAS GOOD. NO DEFECTS NOTED. THE AIRCRAFT WAS RETURNED TO SERVICE.
DURING MAINTENANCE INSPECTION FOUND CENTER FWD DIGITAL CORRODED ABOVE PULLEYS FR 17 ON PREVIOUE REPAIR. THE AIRCRAFT WAS REMOVED FROM SERVICE. PREPPED, PRIMED AND PAINTED CENTER FWD DIGITAL ABOVE PULLEYS ABOVE FR 17 ON PREVIOUS REPAIR IAW EMB 145 CPM 51-21-03, 51-21-04, 51-21-05, 51-21-06 AND ETN-GN-51-008, ETN-51-075 AND ETN-GN-51-016. OPS CHECK GOOD. THE AIRCRAFT RETURN TO SERVICE.
DURING MAINTENANCE INSPECTION FOUND FLOOR PROX EMERGENCY LIGHT CONNECTOR SP9102 BROKEN. THE AIRCRAFT WAS REMOVED FROM SERVICE. COMPLETE AND REPAIRED FLOOR PROX EMERGENCY LIGHT CONNECTOR SP9102 IAW EMB 145 SWPM 20-00-03, 20-21-00 AND 20-50-01. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.
DURING MAINTENANCE INSPECTION FOUND NLG UPLOCK BOX LEFT SUPPORT CRACKED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED CRACKED NLG UPLOCK BOX LEFT SUPPORT IAW EMB SRM 51-40-02. THE AIRCRAFT RETURN TO SERVICE.
ONFLIGHT 4199 THE CREW REPORTED THE CAPTAINâS FLASHLIGHT WAS INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE CAPTAINâS FLASHLIGHT ASSEMBLY IAW MM 33-50-16. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.
DURING MAINTENANCE INSPECTION FOUND THE LEFT WING UPPER EMERGENCY LIGHT IINOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE UPPER EMERGENCY LIGHT ASSEMBLY ON THE LEFT WING IAW AMM 33-50-07. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.
ON FLIGHT 3244 THE CREW REPORTED THE EICAS WENT BLACK THEN SMOKE WAS COMING OUT OF DASH. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FIRST OFFICERâS MFD IAW EMB 145 AMM 34-22-01 OPC GOOD IAW EMB 145 AMM 34-22-00. THE AIRCRAFT WAS RETURNED TO SERVICE.
FLIGHT 3559, CREW REPORTED, AFTER TAKEOFF AT AROUND 3000 FT HAD A MASTER WARNING BATTERY 2 OVERTEMP MESSAGE DISPLAYED ON EICAS. FOLLOWED AOM PROCEDURES AND DECLARED AN EMERGECNY AND RETURNED DEPARTURE. AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPLACED THE BACK UP BATTERY. OPS CHECKED GOOD. AIRCRAFT RETUTNED TO SERVICE.
FLIGHT 3452, DURING CLIMB THROUGH FL180 TO FL230, NOTICED A STRONG BURNING ODOR IN COCKPIT AND FORWARD PART OF CABIN. COMPLETED EPC FOR SMOKE/FUMES IN COCKPIT/CABIN AND DONNED OXYGEN MASKS AND GOGGLES. DECLARED AN EMERGENCY AND DIVERTED. AIRCRAFT LANDED WITHOUT INCIDENT. THERMAL IMAGING SCANS NOTED NO FIRE. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND INSTALLED RIGHT AVIONICS RECIRCULATING FAN IAW AMM 21-26-02. OPS CHECKED GOOD. NO FUMES NOTED. AIRCRAFT RETURNED TO SERVICE.
DURING FLIGHT 4067 THE FLIGHT ATTENDANT REPORTED THE CABIN FORWARD FLASHLIGHT WORKED INTERMITTENTLY. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FLASHLIGHT IAW EMB MM 33-50-16. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.
DURING B-INSPECTION FOUND THE ROW 12 EMERGENCY EXIT SIGNS INOP. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED NR 3 EPSU BATTERY IAW EMB 145 AMM 33-50-04-000-802-AS AND 33-50-04-400-802-A. NO FIX. REMOVED AND REPLACED NR 3 EPSU BATTERY POWER SUPPLY IAW EMB 145 AMM 33-50-04-000-801-A AND 33-50-04-400-801-A OPERATIONAL CHECK WAS GOOD IAW WC 33-700-17 DID NOT REMOVE SEAT. THE AIRCRAFT WAS RETURNED TO SERVICE.
FLIGHT 3560, CREW REPORTED THE EMERGENCY LIGHT SWITCH KNOB WAS BROKEN OFF. AIRCRAFT REMOVED FROM SERVICE. REPLACED EMERGENCY LIGHT SWITCH IAW SPM 20-13-03. THE OPERATIONAL CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.
ON FLIGHT 4067 THE CREW REPORTED THE AFT CABIN FLASHLIGHT SERVICE CLIP IS LOOSE AND THE LIGHT IS NOT CHARGING. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED AFT FLASHLIGHT IAW EMB 145 AMM 33-50-16. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.
ON FLIGHT 3451 THE CREW REPORTED THE E2 FIRE DETECT FAILED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED NR 2 ENGINE FIRE DETECTOR ASSEMBLY IAW EMB 145 AMM 26-11-01. PERFORMED OPS CHECK IAW 26-10-00 AND SYSTEM WORKS GOOD. NO DEFECTS FOUND. THE AIRCRAFT WAS RETURNED TO SERVICE.
ON FLIGHT 3519 THE CREW REPORTED A E2 FIRE DETECT FAIL IN CRUISE. THE CREW ELECTED TO RETURN. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED NR 2 ENGINE FIRE DETECTOR ASSEMBLY IAW EMB 145 AMM 26-11-01. PERFORMED AN OPERATIONAL CHECK IAW 26-10-00 AND SYSTEM WORKS GOOD. NO DEFECTS FOUND. THE AIRCRAFT WAS RETURNED TO SERVICE.
DURING MAINTENANCE INSPECTION FOUND THE LEFT AND RIGHT MASTER CAUTION WARNING LIGHTS DIM. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LEFT AND RIGHT MASTER CAUTION WARNING LIGHT LAMPS IAW EMB AMM 20-13-01. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.
ON FLIGHT 3461 THE CREW REPORTED THE GEAR IN TRANSIT INDICATION DID NOT COME ON DURING RETRACTION OR EXTENSION. THE CREW DECLARED AN EMERGENCY AND ELECTED TO RETURN TO MIA. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND INSTALLED LANDING GEAR ELECTRONIC UNIT (LGEU) IAW EMB-145 AMM32-32-01. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.
ON FLIGHT 3616 THE CAPTAIN REPORTED, ON THE GROUND HAD HIGH WIND UP AROUND 45 KNOTS. TRIMMED ALL THE WAY TO BOTTOM. WHEN CAPTAIN TURNED THE AIRCRAFT INTO THE WIND FOR TAKEOFF, CAPTAIN WAS ABLE TO TRIM INTO TAKEOFF CONFIGURATION. AFTER TAKEOFF AT AROUND 150 -155 KNOTS CAPTAIN ATTEMPTED TO TRIM AND REPORTED CONTROLS STILL FELT HEAVY. SO ATTEMPTED AGAIN AND HAD FIRST OFFICER TRY WITH MAIN AND BACKUP PITCH TRIM AS WELL. NEITHER COULD GET TRIM TO MOVE. RETURNED TO FIELD AND DID DECLARE EMERGENCY, WAS NOT AN OVERWEIGHT LANDING. THE AIRCRAFT LANDED WITHOUT INCIDENT. DID NOT RECEIVE CMC MESSAGES OR EICAS MESSAGES. THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED OPERATIONAL CHECK OF HORIZONTAL STABILIZER ELECTRICAL FLASH ELECTRONIC SYSTEM IAW EMB145 AMM 27-40-00. THE OPERATIONAL CHECK WAS GOOD. ALSO CLEANED THE CAPTAIN'S, FIRST OFFICER'S AND BACKUP TRIM SWITCHES IAW AMM 27-40-03, 04, THE OPERATIONAL CHECK WAS GOOD. NO PARTS REMOVED OR REPLACED. THE AIRCRAFT WAS RETURNED TO SERVICE.
ON FLIGHT 3693 CREW REPORTED THAT THEIR WAS A READING LIGHT THAT WAS FLICKERING AND THEN BEGAN TO EMIT AN ODOR OR SMOKE WHILE IN FLIGHT AIRCRAFT REMOVED FROM SERVICE. UPON INVESTIGATION FOUND CONNECTORS TO BE DAMAGED ON LIGHT ASSEMBLY. REMOVED AND REPLACED LIGHT ASSEMBLY NO FURTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.
VIBRATION FELT INFLIGHT BETWEEN ROW 3 AND ROW 7.
DURING TAKEOFF, CREW NOTED THE AIRCRAFT SHUDDERED WHEN CLIMB THRUST SELECTED AFTER TAKEOFF. REPLACED FADEC 1A AND 1B IAW AMM. PASSED FCF. AIRCRAFT RETURNED TO SERVICE. (M)
DURING APPROACH CREW REPORTED FLAP FAIL AND SPS ADVANCE CAUTION MESSAGES ON EICAS. RESETING BREAKERS DID NOT HELP. MAINTENANCE RESET FLAP ELECTRIC CONTROL UNIT IAW MM. INDICATION RETURNED TO NORMAL AND ALL EICAS MESSAGES WERE CLEARED. AIRCRAFT WAS RETURNED TO SERVICE.