L1 LAVATORY CONTINUOUSLY FLUSHING FLUSH VALVE STUCK IN OPEN POSITION. MANUALLY CLOSED. WATER IS SHUT OFF. TOILET IS INOPERATIVE XFD IAW MEL 3830J. R & R LAV TOILET ASSEMBLY IAW AMM 38-32-01. OPS CHECK GOOD. LEAK CHECK GOOD. REMOVED INOP PLACARD FROM LAV. LAVS G AND J NOT FLUSHING OP TEST OF TOILETS G AND J C/O IAW AMM 38-32-00 R148 SATIS. BOTH WORKING PROPERLY
PUDDLE OF LIQUID UNDERNEATH APU. LIQUID APPEARS TO BE DRIPPING FROM APU. UPON INSPECTION OF APU, FOUND APU RETURN TUBE FOR THE IGV ACTUATOR AND SURGE CONTROL VALVE LEAKING . R & R PACKINGS IAW AMM 49-31-01. OPS & LEAK CHKD GOOD. NO FUEL ODORS NOTED.
NO POTABLE WATER. LAV MOTOR WORKING WITH NO WATER. WATER GAUGE SHOWS FULL. RTB EWR IF AIR IS COMING OUT FROM AFT OVERFLOW DRAIN PORT AT STA 1530, REPLACE VENT OVERFLOW VALVE V130 REF AMM 38-11-05-004-001 EWRMM WORKING ITEM REF LOGPAGE 7804209. INSPECTED PRESSURE RELIEF AT FWD END OF MAIN POTABLE TANK AND FOUND VALVE CLOSED AND WORKING AS REQUIRED DOES NOT REQUIRE REPLACEMENT PERFORMED IN REF WITH AMM 38-15-06-710-803 .
COACH SEAT 30F, 35F, 42F, 47F, & 48F, FOUND ESCAPE PATH LIGHT (SEAT-MOUNTED) BROKEN. REMOVED AND REPLACED ESCAPE PATH LIGHTS. LIGHT POSITIONS 30F,35F,42F,47F, & 48F IAW AMM 33-51-10-962-104. ACCOMPLISHED OPS TEST, ITEMS GOOD FOR SERVICE.
UNSCHED STAB TRIM EICAS MSG ON T/O ROLL APPROX 65KTS. T/O ABORTE D. RTG UNSHED STAB TRIM T/S PFMD IAW FIM 22-05 FAULT TREE 809. FCC COMMUNICATION AND STAB TRIM MSG ON MCDP CLEARED. CHK SATIS. WORKED TWO FIM TASKS "UNSCHED STAB TRIM" PROBLEMS REF 27-09 FAULT TREE 812 BOCK 1,2,3 AND 27 . NO INFC FCC L (C, R) AUTO TRIM ARM DISPLAYED REF 22-05 FAULT TREE 809 SYSTEM IS SATISFACTORY REF BLOCKS 1,11,21. NO LATCHED FAULTS NOTED.
LOWER RED ANTI-COLLISION LIGHT HAS BEEN DEFERRED IN COMPLIANCE WITH CDL CARD 334430 REF LOG PAGE 5883456 APPLIED MEL 3344AD, BOTH (LEFT AND RIGHT) WING TIP WHITE, TAIL CONE WHITE STROBE LIGHTS AND UPPER RED ANTI-COLLISION OPERATE NORMALLY , ALL POSITION LIGHTS (BULBS) OPERATE NORMALLY. APPLIED MEL AND INOPERATIVE STICKER WAS INSTALLED LOWER RED ANTI-COLLISION LIGHT COVER AND LIGHT GOOD REF AMM 33-44-00.
NUMBER 12 SPOILER ACTUATOR LEAKING HYDRAULIC FLUID. INSPECTION FOUND NR 12 SPOILER PCA FAILED. NR 12 SPOILER PCA REMOVED AND REPLACED IAW AMM 27-61-02/401. OP TEST AND LEAK CHECK FOUND NO FURTHER DEFECT.
RT WING, UPPER SKIN PANEL NR 1 TE WS 350.95 & WS 374.05, RIB 6 & 7 CRACKED FROM FASTENER HOLE TO TE. VERIFIED CRACK TERMINATES IN HOLE 14 AS IDENTIFIED ON ECRA 5725- 01157. ACCOMPLISHED NDT OF ADDITIONAL HOLES ADJACENT TO HOLE 14. NO DAMAGE PRESENT. PERFORMED INTERNAL DVI OF THE REAR SPAR CHORD WITH NO DEFECTS NOTED. REINSTALLED FASTENERS. ACCOMPLISHED LEAK CHECK OF ALL REMOVED FASTENERS. ALL STEP S OF ECRA 5725-01157 HAVE BEEN COMPLIED WITH FOR FERRY FLIGHT. JACKED ACFT PERFORMED IN REF AVO14363 AND THE INSPECTIONS MENTIONED IN THE AVO AVO14341 HAS BEEN ACCOMPLISHED WITHOUT NEW CRACKS INDICATIONS. INSPECTED STEP#3 OF AVO14364 REV A, OK.
RIGHT WING UPPER ACCESS PANEL 113T1609-16 CORNER CRACKED. REPLACED PANEL PER SRM 57-51-01.
ETOPS PRE-DEPARTURE SERVICE CHECK REQUIRED. ETOPS PDSC COMPLETED EPDSC EXPIRES . OIL SERVICE ACCOMPLISHED ENGINE 1: 00 CHECKED BY U349089 ENGINE 2: 00
ENG 2 EGT FLUX DRAMATICA LLY JUST AFTER TO POWER SET. NO OVERTE MP INDICAT ED. OTHER ENG PARAM S DEBRIEFED FLIGHT CREW ALL OTHER INDICATIONS WERE NORMAL EGT WAS INTERMITTENT HAVING FLUCUATIONS. INTERROGATED MAINTENANCE MESSAGES CH. 71 AND FOUND AUTO AND MANUAL EVENTS SHOWING THE RT ENG. EGT HIGH COMPARED TO THE LT. PERFORMED FIM TASK 77-21 FT 806 AND FOUND UPPER THERMOCOUPLE HARNESS TERMINAL AT 11 O'CLOCK POSITION BROKEN. REPLACED UPPER HARNESS REF AMM 71-21-02 UP TO STEP 3G. OPS TEST FOR THE EGT INDICATION SYS IS REQUIRED REF AMM 77-21-00-715-012-H00.PARTS USED: 64-7721-3-0006,QTY :1 PERFORMED AMM TASK 77-21-00-715-012-H00 FOR EGT OPS CK. INDICATION STABLE AT IDLE POWER ON #2 ENG.
GOUGES ON THE FUSELAGE SKIN BETWEEN STA1197+231/STA1197+253 AND S-24R/S26R
PDA 2 REF LP 8839646 PANEL #446AL MISSING ON #2 IB STRUT. OK TO CONTINUE.
AFTER TAKEOFF THE TAKEOFF CONFIG WARNING CAME ON INTERMITANTLY A ND COULD NOT B SILENCED T/S PER SSM 31-51-03-101. SUSPECT ONE OF THE AIR GROUND RELAYS A/C OK TO CONTINUE. FOR TAKEOFF WARNING WAS STUCK ENABLING WARNING AFTER TAKEOFF AS 99-2332-3-0034,QTY :1 00-0363-3-0166,QTY :1 CREW CLEANED UP A/C. NO FAULTS PRESENT IN PSEU. REMOVED & REPLACED RELAYS K144 & K211 AS PER AMM 32-09-02. OPS CK GOOD.
AFTER TO AURAL WARNING HORN WOULDNT SILENCE TO/COFIG HORN FLAP/S POILER WARNING FLIGHT. THEY HAD RED SPOILER AND FLAP EICAS MESSAGE PICTURE ATTACHED. DEBRIEFED CREW.... AT 3000 FEET OVER 70% N1 GOING FROM FLAPS 1 TO FLAPS 0 THEY GOT THE T/O WARNING. THEY HAD THIS ALL THE WAY THROUGH UP TO 10K FEET. ANYTIME THEY WENT UNDER 70% N1 THE T/O WARNING WOULD GO AWAY. THEY HAD CLEAN WING IN INDICATION AND IN PERFORMED TAKEOFF CONFIG WARNING SYSTEM OPS TEST IRW AMM TEST PASSED. PARTS USED: 99-3151-9-9003,QTY :1 31-51-00-700-258-C1. TEST SATISFACTORY. R&R''D TAKEOFF ROTABLE PARTS CHANGE WAS INDICATED - TT # 1710767 SN OFF 2055 CONFIGURATION WARNING CARD MODULE IRW AMM 31-51-04. PERFORMED CARD MODULE TEST IRW AMM 31-51-04-724-154 STEPS 4. L THROUGH N.
AFTER T/O DURING FLAP RETRACT FRM F1 TO F UP THE FLAP T/O RED WA RN HORN/LGT ILLUMINATED JUNCTION BOX IS DAMAGED AND HAS BEEN ORDERED WITH TOMC. INSPECTED AIR GROUND SENSING SYSTEM PROXIMITY SENSORS AND FOUND REMOVED LEFT NOSE GEAR NOT COMPRESSED SENSOR REF AMM 32-09-08 THE LEFT NLG SENSOR TO BE DAMAGED. SEE ATTACHED PICTURE. AND TEMPORARILY INSTALLED A REPLACEMENT SENSOR TO VERIFY PHYSICAL GAP BETWEEN SENSOR AND TARGET. TARGET GAP IS OK. CONDUIT FROM LEFT NOSE GEAR NOT COMPRESSED SENSOR TO NLG REPLACED THE LEFT (SYSTEM 1) NOSE LANDING GEAR NOT COMPRESSED SENSOR. REF AMM 32-09-08 AND PERFORMED TEST OF SENSOR ADJUSTMENT REF AMM 32-09-08 WITH NO DEFECTS. ALSO PERFORMED TEST OF TAKEOFF CONFIGURATION WARNING SYSTEM REF AMM 31-51-00 OPS CHECK OK.
DURING FLAP RETRACTION RED FLAPS EICAS MSG W/ASSOCIATED WARNING ALARM ACCELERATING PAST PERFORMED T/S IN REF FIM 31-51 FAULT TREE 808. PERFORMED BITE TEST ON FSEU AND FSPM AND NO FAULT FOUND. PSEU BITE NO FAULT. T/O WARNING TEST PERFORMED IN REF AMM 31-51-00-725-258-002. OPS TEST NORMAL. NO OTHER DESCREPANCIES FOUND AT THIS TIME. ALSO REMOVED AND REPLACED CARD M11281 PER AMM 29-11-69. C ADO O/S TEST PASSED PER AMM TASK 29-11-00-735-116 (P) PARTS USED: 64-2911-9-0006,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1913132 SN OFF 0126 CORRECTING CARD EQUIPMENT NUMBER TO READ R & R C ADP ECC M11291 (P50) CARD, PRINTED C OFF 64-2911-9-0006 0126 ON 64-2911-9-0006 0177 CARD, PRINTED C OFF 64-2911-9-0006 0126 ON 0000 UNIT, PRINTED C OFF 99-3151-9-9003 1892 ON 0000 UNIT, PRINTED C OFF 99-3151-9-9003 1892 ON 99-3151-9-9003 2066 PERFORMED CENTER HYDRAULIC SYSTEMS TEST IN REF AMM 29-11-00-735-116, DUE TO C ADP HISTORY, ALL TEST & IND NORMAL. AS PRECAUTIONARY, SUGGEST TO REPLACE T/O CONFIG MODULE M620 AND M11291 ADP CONTROL CARD. (MFG#285T0259-19, SN#D01892) AT POSITION M620 (TAKEOFF/WARN CONFIG CARD). PERFORMED AMM 31-51-04/401 FOR REMOVAL AND REPLACEMENT AND PERFORMED TEST PROCEDURE AMM 31-51-04-864-108 . OPS CHECK OK. NO FAULTS FOUND.
L SEC HX SNSR AND LT COND TEMP CONTROL STATUS MESSAGES DISPLAYED INTERMITTENTLY BITE L CTC FOUND MSG L SEC HX OUT SNR 21-51236, L COND IN SNR 21-51230. DURING ARRIVAL L RAM DOOR WAS CLOSED, PERFORMED RAM DOOR ACUATOR TEST DID NOT PASS. DID NOT OPEN. NEEDS RAM INLET ACTUATOR. ALSO UPOND ARRIVAL PERFORMED OVERWEIGHT LANDING REMOVED PANEL 193ML FOR ACCESS TO LH RAM AIR ACTUATOR INSPECTION REF AMM 05-51-35, FOUND NO FURTHER DMG. ACTUATOR, RAM A OFF 64-2153-9-0001 8002 ON 64-2153-9-0001 0205 ACTUATOR, RAM A OFF 64-2153-9-0001 8002 ON 0000 REPLACED LH RAM AIR DOOR ACTUATOR AND OPS CHECK NORMAL REF AMM 21-53-03.
EICAS CAUTION 3 TIMES L ENG FUEL FILT STATUS MESSAGE AS WELL :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1836143 SN OFF 5952 R/R L ENGINE FUEL FILTER REF AMM. 73-11-03. DRY MOTORED ENGINE, NO LEAKS PRESENT. R/R FUEL PRESSURE SWITCH ON LEFT ENGINE. L ENGINE RUN PREFORMED, NO LEAKS PRESENT. L ENGINE FUEL FILT STATUS MESSAGE NOT PRESENT. ALSO, STBY ATT INDICATOR FAILED AT 23000 FEET SHOWED 20 DEG NOSE DOWN 10 DEG LEFT IN LVL FLT. R/R STBY ATT INDICATOR. PARTS USED: 64-3424-9-0001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1910913 SN OFF 0213
*EMERGENCY*MULTIPLE FLIGHT ATTENDTS REPORTED A BURNT SMELL AT ROW 19. LOCKED FOR MX SHUT DOWN. UNLOCKING TO UPDATE. LOCKING FOR POSITIVE FIND AND FIX SMOKE SMELL ALSO NOTICEABLE BY F/A AND PAX AT R ROWS 19 AND 20, ROWS LEFT 35-37. AFTER REPORT OF SMOKE CREW SHUTE DOWN IFE AND POWER TO THE CABIN INTERIOR LIGHTING. CHECKLIST RUN SHUTING DOWN IFE AND UTILITY BUS. SMOKE DISSIPATED ONCE POWER TO SYSTEM WAS ELECTRICAL SYSTEM TEST. P101 FAULT SELF CORRECTED AFTER RUN. UNLOCKED FOR UPDATE. IFE SYSTEM WONT POWER UP. T/S PER WDM 23-32-11-1. FOUND NO POWER ACCOMPLISHED BPCU BITE CHECK, BPCU HAS NO FAULTS. T/S PER WDM AT P101 ELETRICAL SYSTEMS PANAL. IFE BUSS ARE UNPOWERED. 23-32-11-1, FOUND LOAD SHED SIGNAL FROM BPCU AT BOTH ELCU M7254 AND M7253. ACCOMPLISHED ENGINE RUN AND ELECTRICAL SYSTEMS GENERATION TEST. REF AMM 24122100-501. RIGHT AND LEFT A/C AT POWER UP. IFE SYSTEM IS INOP. LOSS OF COOLING LIGHT IS ON. T/S PER WDM 23-32-11-1. FOUND NO POWER AT P101 CIRCIUT BRAKER POWER PANEL.. DETAILS AWAITED.
R TRIM AIR CONT STATUS MESSAGE RESET R/H TRIM AIR SYS OPS CHECK GOOD
UNABLE TO CONTROL FLT DECK AND FWD CABIN TEMP FOUND TRIM VLV POSTIONS FOR FLT DCK, MID1, MID2 BLANK ON MAINTENANCE PG BLANK, FOUND FD TEMP SEL 21-61211 AND R CTC CH2 FAIL 21-61003 ON R/H CTC. R&R R/H CTC IAW MM 21-61-20 OPS CHECK GOOD ROTABLE PARTS CHANGE WAS INDICATED - TT # 1051355 SN OFF 2697 IPC REFERENCE # 21-61-62-01B
R GEN DRIVE EICAS DISCONNECTED GEN IDT REQUIREMENTS C/W FOR IDG FEEDER CABLE TORQUE. UPDATED LABOR HOURS. REMOVED AND REPLACED #2 ENG IDG AS PER AMM 24-11-01. NEEDS OPS NEED TO TORQUE IDG FEEDER CABLE ON #2 ENG. TORQUED IDG FEEDER CABLES AS PER AMM 24-11-01 ON #2 ENG. AND LEAK CHECK. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1803657 SN OFF 1095 GENERATOR, INTE OFF 64-2411-9-0002 1095 ON 64-2411-9-0002 1284 PERFORMED OPS AND LEAK CHECK. OPS CHECK GOOD AND NO LEAKS NOTED. A/C OK TO CONTINUE.
STATUS MSG L BLEED HPSOV DURING TROUBLESHOOTING, FOUND ASCTU LT FAILED, WITH MX MESSAGE T/S FOUND HPSOV DAMAGED SEE PIC. FURTHER TROUBLESHOOTING REVEALED A BROKEN VALVE RING IN LT 36-13001, IAW FIM FAULT TREE 812. R&R ASCTU IAW AMM 36-11-22. HPSOV. R&R HPSOV IAW AMM 36-11-07, UP TO, AND INCLUDING STEP ASCTU PASSES SELF TEST / INSTALLATION TEST. BUT LT HPSOV MX 3.E.12. REQUIRES INSTALLATION TEST, IAW AMM 36-11-07, STEP 3.F. MESSAGE REMAINS. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1929112 SN OFF 5050 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1913128 SN OFF 1105 VALVE, ASSY, HI OFF 64-3611-9-0007 5050 ON 64-3611-9-0007 7000 UNIT, AIR SUPPL OFF 64-3600-9-0002 1105 ON 64-3600-9-0002 8559 C/W AMM 36-11-07, STEP 3.F., INSTALLATION TEST, TO COMPLETION. NO FAULTS FOUND, ALL MESSAGES CLEARED, OPS CHECKS GOOD.
AS 2012-09-04 SUPPORT TASK EA 5340-01385 REV ORIG OP 001 LH STA 955 REAR BULKHEAD FAILSAFT STRAP 1EA FASTENER HOLE FOUND 2EA CRACKS RUNNING FWD AND AFT TRANSFER REF. NON-ROUTINE LP 9131340 AND ORIGINATED BY EMP NO. V906014 LH STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP REPAIRED AS PER EA 5340-01385 REV ORIG OP 003 WORK ACCOMPLISHED BY MECHANIC V906014 INSPECTED BY V893003 ADD EMP:V906014 INSPECTED BY HX243551, APPROVED.
AD 2012-09-04 SUPPORT TASK EA 5340-01385 REV ORIG OP 002 STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP 1EA FASTENER HOLE FOUND 2EA CRACKS RUNNING FWD AND AFT TRANSFER REF. NON-ROUTINE LP 9131338 AND ORIGINATED BY EMP NO. V906014 RH STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP REPAIRED AS PER EA 5340-01385 REV ORIG OP 004 AND WORK ACCOMPLISHED BY EMP V893003 AND INSP HX243551
AS 2012-09-04 SUPPORT TASK EA 5340-01385 REV ORIG OP 001 LH STA 955 REAR BULKHEAD FAILSAFT STRAP 1EA FASTENER HOLE FOUND 2EA CRACKS RUNNING FWD AND AFT TRANSFER REF. NON-ROUTINE LP 9131340 AND ORIGINATED BY EMP NO. V906014 LH STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP REPAIRED AS PER EA 5340-01385 REV ORIG OP 003 WORK ACCOMPLISHED BY MECHANIC V906014 INSPECTED BY V893003 ADD EMP:V906014 INSPECTED BY HX243551, APPROVED.
SUPPORT TASK (TAR) DURING ACCOMPLISH EA 5340-01385 REV ORIG OP 004 RH SIDE STA 955 REAR SPAR BULKHEAD FAIL STRAP STRAP REPAIR, AT STEP -14.0 PREPARE NEW T-FITTING FOR INSTALLATION, WE FOUND THE I/B ROW AFT 5EA FASTENER HOLES HORT EDGE MARIGIN TRANSFER REF. NON-ROUTINE LP 9132161 AND ORIGINATED BY EMP NO. V893003 EA 5340-01385 REV ORIG OP 004 R/H STA 955 REAR SPAR BULKHEAD WORK ACCOMPLISHED BY MECHANIC V893003 INSPECTED BY V897471 FAILSAFE STRAP REPAIR AT STEP 14.0 NEW T-FITTING FASTENER HOLES SHORT EDGE MARGIN LOCATION A REPAIR GUSSET PLATE WAS INSTALLED AND PLUGGED AS PER EC/RA 5340-02004 REV ORIG ACCOMPLISHED ATTACH FORM 44.0008 ITEM 1-12 ACCOMPLISHED ADD EMP:V897471 INSPECTED BY HX182816, APPROVED.
B767-53-3-0172 CABIN STA 303 LBL 13 TO 53 FLOOR BEAM FOUND CORROSION TRANSFER REF. NON-ROUTINE LP 9131181 AND ORIGINATED BY EMP NO. V897790 CABIN STA 303 LBL 3" TO LBL 66" FLOOR BEAM REPAIRED AS PER SRM 53-00-51-2R-1 REPAIR 1 FIG 201 ATTACH FORM 44.0008 ITEM 1-24 ACCOMPLISHED ADD EMP:V897790 INSPECTED BY HX203141, APPROVED.
EMERGANCY LIGHT BATTERY INOP ( LH ROW 40) REMOVED AND REPLACED EMERGENCY LIGHT BATTERY(ROW 40BA) REF B767-400 AMM 33-51-07 REV 133
EMERGENCY LIGHT BATTERY INOP (ROW 19LK) REMOVED AND REPLACED EMERGENCY LIGHT BATTERY (ROW 19LK) REF. B767-400 AMM 33-51-07 REV 133
EMERGANCY LIGHT BATTERY INOP ( LH ROW 30) REMOVED AND REPLACED EMERGENCY LIGHT BATTERY REF 767-400 AMM 33-51-07 REV 133
EMERGANCY LIGHT BATTERY INOP ( LH ROW 41) REMOVED AND REPLACED EMERGENCY LIGHT BATTERY( LH ROW 41) REF B767-400 AMM 33-51-07 REV 133
EMERGENCY LIGHT BATTERY INOP(ROW 24LK) REMOVED AND REPLACED EMERGENGY LIGHT BATTERY (ROW 24 LK) REF. B767-400 AMM 33-51-07 REV 133
EMERGENCY LIGHT BATTERY INOP(ROW19BA) REMOVED AND REPLACED EMERGENCY LIGHT BATTERY (ROW19BA) REF B767-400 AMM 33-51-07 REV 133
DURING FLIGHT, HAD A FUEL LEAK FROM THE NR 2 ENGINE, FLIGHT DIVERTED. FOUND A FUEL LINE FROM IDG FUEL OIL COOLER DAMAGED. THE LINE WAS REPLACED IAW AMM 24-11-10-424-007-001, IDLE LEAK CHECK TEST PERFORMED. FOUND ALL GOOD.
BS 1654 - 1678, STRINGER 13AR SKIN FOUND CRACKED. REPAIRED IAW SRM 53-80-01, REPAIR 7, FIG 202.
LEFT PYLON PS 223, MID SPAR WEB FOUND CRACKED AT IDG FEED THROUGH CUTOUT POSITION. REPAIRED IAW SRM 54-55-01, REPAIR 2, FIG 203.
MCD 2L EMERG EXIT LIGHT WILL NOT TURN ON DURING FA TEST. RELAMPED DOOR SILL LIGHT AT 2L,ALL LIGHTS NOW TEST NORMAL DURING EMERGENCY LIGHT TEST REF AMM33-51-00.
EMERGENCY LIGHTS FROM SEAT ROWS 24 TO 28 LEFT AND RIGHT SIDES ARE INOPERATIVE. FOUND THE CONNECTOR LOOSE. CONNECTED AND OPS CHECKED GOOD IAW WDM 33-51-13.
EMERGENCY FLASHLIGHT NOT CHARGING REMOVED AND REPLACED THE BATTERY IAW AMM 25-60-98. OPS CHECKED GOOD.
STBY ALT HANGS UP THEN JUMPS 300 FEET DURING CLIMB. REMOVED AND REPLACED THE STBY ALT IAW 34-13-06, OPS CHK NORMAL, A/C REMAINS FULLY CAT QUALIFIED.
MID GALLEY EMERGENCY LIGHT LENS COVER IS MISSING. REATTACHED MID GALLEY EXIT LIGHT LENS.
ON APPROACH, LE SLAT DISAGREE & TE FLAP DISAGREE EICAS WITH TE FLAP SHUTDOWN & LE SLAT SHUTDOWN STATUS. PERFORMED BITE OF FSEU IAW FIM 27-51-00-815-809, NO MSG NOTED ON EICAS. CYCLED FLAPS SEVERAL TIMES, NO FAULTS NOTED. OK TO CONTINUE IAW AMM 27-51-01.
EICAS STATUS MSG, GEAR CONTROL, PERFORMED OPERATIONAL TEST OF LG CONTROL SYS IAW AMM TASK 32-31-00-715-001-0-01-1, WITH GOOD RESULTS. FAULT DID NOT REPEAT & EICAS MSG WENT AWAY, OK TO CONTINUE. FURTHER TROUBLESHOOTING, FOUND A SEQUENCE ISSUE WITH GEAR DOOR OPERATION ON GND. FOUND SWITCH S260 INDICATING INCORRECTLY. R & R EXTEND TEST SUCCESSFUL.
DURING DESCENT THRU 15000 FT FOLLOWING GEAR MALFUNCTION THE FOLLOWING STATUS MSGS OCCURRED. AIR & GND DISAGREE, RT ICE DET, LT ICE DET, RT REV ISLN VLV, GEAR CTL, YSM, & FIRST OFFICERS DISPLAY T - R UNIT RII VERIFIED ASSEMBLY PN & CLEARANCE TO INSTALL FN085211. REMOVED & REINSTALLED SELECTOR BYPASS VLV FOR MLG UP TO MM 32-31-04-404-060 STEP 14 TEH U90700. ACCOMPLISHED MM 32-31-04-4 04-060 STEP E 13 THRU G2. SYS OPERATIONS CHECKED GOOD.
CABIN STATION 325, LBL 20 - 55 FLOORBEAM UPPER CHORD CORROSION FOUND. CORROSION REMOVED IAW SRM 51-10-02. BLEND OUT AREA D0.030" W1" L2", ORG THK0.090", OUT OF SRM 53-00-51 ALLOWABLE DMG 1 FIG 101 LIMIT. UPPER CHORD CORRODED, AREA REPAIRED IAW SRM 53-00-51 REPAIR 1 FIG 201 AT RBL 48 - LBL 64.
CABIN STATION 303, LBL 15 - 55 FLOORBEAM UPPER CHORD CORROSION FOUND. REPAIRED IAW SRM 53-00-51 REPAIR 1 FIG 201 AT LBL 8 - 64. FLOORBEAM UPPER CHORD CORROSION REMOVED IAW SRM 51-10-02. BLEND OUT AREA D0.060 INCHES, ORG THK0.090 INCH, L3" W1" OUT OF SRM53-00-51 ALLOWABLE DMG 1 FIG 101 LIMIT.
OVEN 107 HAD SOME SMOKE & ODOR WHEN USED 2ND TIME IN FLIGHT. ODOR DID NOT APPEAR TO BE ELECTRICAL, SMELLED LIKE HOT PLASTIC. PERFORMED CONDITIONAL INSPECTION IAW AMM TASK 05-51-58-200-801C 1, OPERATIONS CHECKED NORMAL AFTER CLEANING OF SPILLED FOOD.
COCKPIT FLASHLIGHT INOPERATIVE. R & R BATTERY IAW GMM 05-20-10, ITEM 9.
DOOR 2L EXIT LIGHT FOUND DIM DOOR 2L EXIT LIGHT REPLACED AND TEST NORMAL IAW AMM 33-51-01.
CABIN RT, BS 1283, RBL 88.5 SEAT TRACK CROWN CORROSION REVEALED AFTER PAX SEAT REMOVED. CABIN RT BS 1283 RBL 88.5 SEAT TRACK STA 1208 TO 1428. REPAIRED IAW ECRA 5320-02077.
GATE RETURN. F/A REPORTED STRONG SMOKE/SULFER SMELL THROUGHOUT A/C. COCKPIT SMELLED A SULFER SMELL. GATE RETURN IN INTEREST OF SAFETY FOR INSPECTION. NOTE BAT PWR WHEEL CHAIR IN BELLY. ACCOMPLISHED AMM 05-51-58 CONDITIONAL INSPECTION NO SMOKE/ODOR FOUND. FLIGHT CREW QUESTIONNARE FORMS FILLED OUT.
CAPT O2 STOWAGE BOX OXYGEN ON FLAG DOES NOT WORK. REPLACED CAPT O2 STORAGE BOX PER AMM 35-11-51-404-009.
NOTICED ELECTRICAL BURNING SMELL, ABOUT 30 SEC LATER LEFT RECIC FAN EICAS MSG AND LEFT RECIRC FAN INOP LIGHT CAME ON, SMELL DISSAPEARED - NO SMOKE WAS SEEN. FOUND LEFT RECIRC FAN AT FAULT, REMOVED AND REPLACED LEFT RECIR FAN PER MM 21-25-01-004-0053, AS FOR PRECAUTIONARY REPLACED LEFT AND RIGHT RECIRCULATION AIR FILTER, ALL OPS CHECK GOOD OK TO CONT. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1474816 S/N OFF 01484 FAN, AIR, COOL OFF 25-2127-9-0006 1484, ON 25-2127-9-0006 2067.
R4 DOOR EMER EXIT LIGHT INOP ON BULKHEAD JUST ABOVE FLT ATTEND SEAT. REMOVED & REPLACED BATTERY CHARGER & BATTERY PACK ASSY, AND PERFORMED EMERGENCY LIGHT TEST, OPS CHECK NORMAL PER AMM 33-51-07 P. 204.
FOUND FLASHLIGHT DOOR 4R F/A FACE AFT INOP. REPLACED FLASHLIGHT BATTERY P/N-6-1020 ME 24-2500-3-0012. OK FOR SERVICE.
B767-57-3-0130 RT WING NR 9 SLAT EXT SURFACE 2 EA RIVET HOLES SURROUNDING FOUND CRACK. RT WING NR 9 SLAT OUTER SKIN SURFACE 2 RIVET HOLES CRACKED. REPAIRED AS PER SRM 57-43-01 REPAIR 2 FIG 201 AT 0SS572.549 AND OSS568.14 9 AND FORM 44.0008 ATT ITEM 1-18 ACCOMPLISHED.
LT WING NR 3 SLAT OUTER SURFACE LOWER AREA 3EA RIVET HOLES SURROUNDING AREA FOUND CRACK. LT WING NR 3 SLAT OUTER SKIN SURFACE LOWER AREA 3 RIVET HOLES CRACKED AREA REPAIRED AS PER SRM57-43-01 FIG 201 REPAIR 2 AT OSS723.941 AND OSS722.441 AND FORM 44.0008 ATT ITEM 1 - 17 ACCOMPLISHED.
B767-53-3-0172 STA 325 LBL 55 TO RBL 55 FLOORBEAM UPPER CHORD FOUND SEVERAL CORRODED. BS 325 FLOORBEAM UPPER CHORD CORROSION REMOVED AS PER SRM 51-10-02, BLEND OUT D0.035" (ORG THK 0.090") W1"L2.5" OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMITS & FLOORBEAM UPPER CHORD CORRODED AREA REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AT BS 325 LBL 63 TO RBL 55 & FORM 44.0008 ATTACHED ITEM 1 TO 10 ACCOMPLISHED.
B767-53-3-0172 STA 303 LBL 11 TO 55 FLOORBEAM UPPER CHORD FOUND SEVERAL CORRODED. BS 303 FLOORBEAM UPPER CHORD CORROSION REMOVED AS PER SRM 51-10-02, BLEND OUT AREA DEPTH 0.060" (ORG THK 0.100") WIDTH 1 INCH, LENGTH 3 INCHES OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT AND FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AT BS 303 LBL 7 TO LBL 63 & FORM 44.0008 ATTACHED ITEM 1 TO 10 ACCOMPLISHED.
LEFT MAIN GEAR PARTIAL COLLASPE DURING TAXI WHILE AIRCRAFT STOPPED. LEFT MAIN GEAR BEAM SNAPPED. REMOVED AND REPLACED LEFT MLG TRUCK BEAM ASSY PER ECRA 3210-02173, PERFORMED HARD LANDING AND INNER CYLINDER INSP PER ECRA 3200- 01423, OPS CHECK PERFORMED PER ECRA 3210-02173, ALL CHECKS GOOD.
ELECTRICAL SMELL FROM COFFEEMAKER NR 605/606 C/B`S PULLED. COFFEEMAKER NR 605 CHECKS OK. REMOVED AND REPLACED COFFEEMAKER NR 606 PER CMM 25-33-05. ROTABLE PARTS CHANGE WAS INDICATED - TT 1366548 S/N OFF 00998 COFFEEMAKER, S/N ON 0324.
DOOR 4 EMERGENCY EXIT LIGHTS FLASH ON/OFF APPROXIMATLEY EVERY 10 SECONDS. CHANGED EMERGENCY BATTERY CHARGER AND BATTERY PACK PER AMM 33- 51-07, OPS CHECK GOOD.
DOOR R4 EMERGENCY LIGHT AFT WALL AND DOOR LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY CHARGER PER AMM 33-51-07 AND OPS CHECKED GOOD.
LEFT-HAND WING LEADING EDGE BEAM FOUND CRACKED AT LEADING EDGE STATION 679. REPAIRED PER SRM 57-41-13.
BS 325 LBL 22-44 FLOOR SUPPORT FOUND CORRODED. FLOORBEAM REPAIRED PER SRM 53-00-51.
BODY STA 246 FLOORBEAM LBL 40 MID CHORD CRACKED. FLOORBEAM MID CHORD REPAIRED PER ECRA 5310-04718.
BS 246 FLOORBEAM LBL 40 FORWARD SIDE STIFFENER FOUND CRACKED. STIFFENER REPLACED AND INSTALLED PER SRM 53-10-51 REPAIR 4 FIG 201.
CABIN STA 303 LBL 15 TO 32 FLOOR SUPORT UPPER CHORD FOUND CORRODED. FLOORBEAM REPAIRED PER SRM 53-0051.
STA 303 TO STA 325 LBL 30" FLOOR SUPPORT FOUND CORROSION. REMOVED AND REPLACED AFT FLOOR PANELS PER SRM 51-40-02.
FOUND SEAT 38C PAX OXYGEN MODULE DOOR INOP. REPLACE LATCH PER AMM 35-21-00.
CABIN FLOORBEAM CORRODED AT BS 325 LBL 26 TO 52. REPAIRED FLOORBEAM PER SRM 51-10-02 AND 51-20-01.
CABIN FLOORBEAM CORRODED AT BS 325 LBL 33 - LBL 55. REPAIRED FLOORBEAM PER SRM 53-00-51.
CABIN FLOORBEAM CORRODED AT BS 303 LBL 18 TO 35. REPAIRED FLOORBEAM PER SRM 53-00-51, FIG 201.
THE R-3 EMERGENCY EXIT DOOR INTERIOR HANDLE DOES NOT BACK AGAINST THE DOOR LINING AT ONCE DURING OPERATIONAL CHECK. THIS WOULD HAVE PREVENTED THE EMERGENCY ESCAPE SLIDE FROM DEPLOYING. PERFORMED TORSION SPRING ADJUSTMENT ON THE TORQUE TUBE IAW MM 52-22-01. PAGE 511. OPERATIONAL CHECKS OF THE EMERGENCY DOOR WERE GOOD.
THE L-3 EMERGENCY EXIT DOOR INTERIOR HANDLE DOES NOT BACK AGAINST THE DOOR LINING ONCE DURING OPERATIONAL CHECK. THIS WOULD HAVE PREVENTED THE EMERGENCY ESCAPE SLIDE FROM DEPLOYING. PERFORMED TORSION SPRING ADJUSTMENT ON THE TORQUE TUBE IAW MM 52-22-01, PAGE 511. OPERATIONAL CHECKS OF THE EMERGENCY DOOR WERE GOOD.
WHEN MLG WAS SELECTED TO DOWN ON APPROACH TO FCO CREW REPORTED THAT ALL WAS QUIET & NOTHING HAPPENED. ALT GEAR EXTENSION USED & CREW GOT EICAS MSG GEAR DISAGREE AND NO GREEN NLG LIGHT. ALT GEAR EXTENSION USED AGAIN DURING A GO AROUND AND 3 GREEN MLG LIGHTS WERE ILLUMINATED. A/C LANDED W/O PROBLEM. GEAR SWUNG 3 TIMES & ALL OPS CHECKED GOOD. GEAR AREA INSPECTED INCLUDING GEAR, DOORS, ALL THE STOPS, AND CONTROL MECHANISMS & NO FAULTS WERE FOUND. GEAR FULLY LUBRICATED & MLG LEVER CONTROL MODULE (SWITCH) R & R IAW MM 32-31-01 AS A PRECAUTIONARY MEASURE. MLG CONTROL SYS, ALT EXTEND SYS, & POSITION INDICATION WARNING SYS TESTED IAW MM 32-31-00, 32-35-00, AND 32-61-00 AND ALL TESTS PASSED WITH NO DEFECTS NOTED.
THE LEADING EDGE DEVICE WAS FOUND HANGING ON RIGHT WING JUST INBOARD OF RIGHT ENGINE DURING WALKAROUND. MAINTENANCE FOUND BOLT FROM LINK SHEARED AND LINK DAMAGED AT KRUEGER SEAL DRIVE. THE LINK AND BOLT WERE REPLACED IAW MM 767-400-27-81-19, PAGE 401. OPERATIONAL CHECKS WERE GOOD.
INSPECTION FOUND THE EXTERIOR EMERGENCY SLIDE ILLUMINATION LIGHT AT R-4 DOOR INOPERATIVE. THE M734 EMERGENCY LIGHTS POWER SUPPLY WAS REMOVED AND REPLACED IAW MM 33-51-07, PAGE 201.