Accident & incident history
Maintenance disclosures
DURING THE ACCOMPLISHMENT OF NR 3478075, A DELAMINATED AREA WAS FOUND ON THE RH SIDE OF THE RUDDER. IT WAS REMOVED THE FASTENERS AROUND THE DAMAGE AREA AND REMOVED DAMAGED OF THE RUDDER, PERFORMED I NSPECTON E APPROVED THE MATERIALS, PERFORMED PERMANENT REPAIR AS PER SRM 55-40-01-2R-1 AND SRM 51-70-04-0G-0 PARAGRAPH 4, INSTAL LED THE RIVETS AS PER SRM 51-40-02-0G-0 AND PERFORMED PAINT AS PER AMM 51-21-10-377-003.
TE FLAP DISAGREE FOLLOWED CHECKLIST PERFORMED FSEU BITE TEST PER FIM 27-51 FAULT TREE 809 FOUND MSG 27-81045. PERFORMED BITE TEST ON PSEU PER FIM TASK 32-09 FAULT TREE 803, FOUND FAULT CODE 297 FOR R SLAT #9 OUTB. FLAPS DO NOT MOVE UP IN NORMAL MODE RECONFIGURED F/D TO NORMAL AND OPERATED FLAPS AND SLATS HYDRAULICALLY, OPS AND INDICATIONS CHECK GOOD WITH NO TE DISAGREE AT ANY TIME. PERFORMED BITE OF FSEU PER FIM 27-51 FAULT TREE 809, NO EXISTING FAULTS AND ONLY FAULT ON LEG -0 WAS ALT UP DISAGREE DUE TO ALT FLAPS BEING SELECTED. CHECKED FLAP CONTROL CABLE WFA AND WFB TENSIONS PER AMM 27-51-00-825-001. AT CURRENT TEMP, CABLES SHOULD BE BETWEEN 57 AND 67 LBS (RECOMMENDED TO BE RIGGED TO THE HIGH SIDE), BUT ARE READING BELOW TOLERANCE AT 43LBS. FLAP CONTROL CABLE WFA AND WFB REQUIRE ADJUSTMENT. ADJUSTED FLAP CONTROL CABLE WFA AND WFB BACK WITHIN TOLERANCE AND TO THE HIGH SIDE OF THE LIMIT PER AMM 27-51-00-825-001. OPS CHECKS GOOD. OK TO CONTINUE. RII CW ON WFA AND WFB CABLE TENION PER AMM 27-51-00-825-001. OK TO CONTINUE. CHECKED FLAP CONTROL CABLE WFA AND WFB TENSIONS PER AMM 27-51-00 -825-001. AT CURRENT TEMP, CABLES SHOULD BE BETWEEN 57 AND 67 LB S (RECOMMENDED TO BE RIGGED TO THE HIGH SIDE), BUT ARE READING B ELOW TOLERANCE AT 43LBS. FLAP CONTROL CABLE WFA AND WFB REQUIRE ADJUSTMENT. ADJUSTED FLAP CONTROL CABLE WFA AND WFB BACK WITHIN TOLERANCE AND TO THE HIGH SIDE OF THE LIMIT PER AMM 27-51-00-825 -001. OPS CHECKS GOOD. OK TO CONTINUE.
OUTER ESCAPE LIGHT LAMP FOR R4 DOOR INOPERATIVE. REMOVED AND REPLACED LAMP IAW AMM 33-51-06.
OUTER ESCAPE LIGHT LAMP FOR L4 DOOR INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-51-06.
AFTER ENGINE START THE L GEN EICAS ILLUMINATED RAN CHECKLIST AND RESET L GEN SUCESSFULLY REMOVED AND REPLACED BOTH L GCU & BPCU REF AMM 24-22-02 & FIM 24-20-04. NO FAULTS FOUND AND OPS CHECK GOOD AFTER ENGINE RUN.
DAMAGE FOUND ON DOOR 4R SLIDE BUSTLE. COMPLIED WITH EC/RA 2566-01351 PART 1 INTERIM REPAIR TO IT COMPLETION. PLACING ITEM ON DIP PER ECRA 2566-01352 PART 2.
R4 DOOR WONT ARM. REMOVED DOOR SLIDE BUSTLE & INSTALLED SLIDE SAFETY PIN IAW AMM 25-66-01-004-001. FOUND BROKEN PAWL ON EXTERIOR HANDLE, REMOVED AND REPLACED THE R4 DOOR PAWL IAW AMM 52-11-26, DOOR ARMS AND DISARMS NORMAL. REMOVED THE DOOR SLIDE SAFETY PIN AND REINSTALLED SLIDE BUSTLE IAW AMM 25-66-01.
LEFT PACK OFF L ENG BLEED OFF OCCURRED DURING TAKEOFF ROLL 80 KNOTS AS PER FLT CREW DEBRIEF BLEED SYS RECOVERED FOLLOWING TMOC REQUEST. PRECAUTIONARY ACCOMPLIHSED CTC BITE PER FIM 21-61-00/101 FIG 103. ALL IND NORMAL.
DOOR 4R SLIDE COVER LOOSE. DOOR 4R BUSTLE REPOSITIONED, NOW OK FOR FURTHER SERVICE PER AMM 25-66-11-404-004 REV 145.
BOTH EMERGENCY FLOOR PATH LIGHTS IN AFT RIGHT GALLEY HAVE CRACKED LENSES. REQUIRES REPLACEMENT. REPLACED EMERGENCY FLOOR PATH LIGHTS IAW CMM 25-02-80. OPS CHECK GOOD.
LE FLAP ASYM EICAS ON FLAP RETRACTION 1 TO UP WHEN A/C ARRIVED AT GATE, NO MSG PRESENT. CREW SAYS EICAS MSG WA S INTERMITTENT. ON BIT TEST OF FSEU, FOUND FAULT CODE 27-81021, LE OTBD ASYM IN FAULT HISTORY. VISUALLY INSPECTED & CLEANED PROX SENSORS M276 & M297 L SLAT #1 OUTBD, & RT SLAT 9 OTBD. R&R FSEU UP TO STEP (8) FLAP POS TRANSMITTER CHECK. DURING CHECK, FOUND M473, M492,M491,M489 OUT OF LIMITS. REMOVAL AND REPLACEMENT OF FSEU REF TASK 27-51-01-404-130. OUT OF LIMIT SENSORS. TRANSMITTER M473, M489, M491 AND M492 ADJUSTED IN REFERENCE WITH AMM 27-51-45. OPS CHECK CARRIED OUT IAW AMM 27-51-00. FOUND SATISFACTORY. NO MESSAGE ON EICAS
NECESSARY REPLACED THE SERVICE DOOR EMERGENCY ESCAPE SLIDES 4RH AS PER TASK CARD 64-2560-1-3800 IT WAS REMOVED AND REPLACED THE SERVICE DOOR EMERGENCY ESCAPE SLIDES 4RH AS PER AMM 25-66-01.GOOD FOR SERVICE.
L1 DOOR GIRT BAR CARRIER AFT CABLE RETRACT ASSY., CABLE BINDING INTERMITTENTANTLY. REPLACED L1 GIRT BAR CARRIER DEPLOYMENT CABLE RETRACTORS REF AMM 25-66-03-404-015
WX RADAR INOP. REPLACED WEATHER RADAR ANTENNA AMM 34-43-05-024, OPS CHECK OK.
LH LOCK SPRING AT NOSE LANDING GEAR LOCK LINK BROKEN. THE UPPER PART OF THE SPRING WAS MISSING UPON ARRIVAL IN BER. LH LOCK SPRING AT NOSE LANDING GEAR LOCK LINK INSTALLED IAW AMM 32-21-09-404-010 REV 141. NEW SPRING P/N 162T3033-3 AND FWD SPOOL P/N 162T3010-2 USED. AREA CLEANED AND INSPECTED, FOUND ALL SATIS.
ANTISKID EICAS MSG COMES UP INTERMITTENTLY WITH ASSOCIATED STATU S MESSAGES A/C HAS HISTORY DEBRIEFED FLIGHT CREW AND NO HIGH ENERY STOP WAS PERFORMED ALSO NO ANTISKID WAS USED . PART UPDATED FOR TRANSDUCER #5. IN STOCK AT EER PERFORMED BITE PROCEDURE AS PER AMM TASK 32-42-01-704-013-001. FAULT XDCR 5 APPEARED. INSTALL NEW ANTISKID CONTROL UNIT , NO HELP SAME FAULT. REINSTALLED FIRST ANTISKID CONTROL UNIT AS PER AMM TASK 32-42-01-424-006-001. SUGGEST FUTHER T/S ON FAULT XDCR 5. R/R #5 MLG ANTISKID TRANSDUCER IN REF WITH AMM 32-42-05. PERFORMED BITE TEST AS PER AMM 32-42-01-704-013-001. BITE TEST PASSED. NO FAULTS NOTED AT THIS TIME. PARTS USED: 1522365,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1522365 SN OFF 4107 IPC REFERENCE # 32-11-26-01.
EQUIP COOLING VALVE LIGHT CYCLED ON AND OFF CONTIUOSLY. REPLICATED FAULT WITH SWITCH IN STANDBY POSITION AND T-SHOT TO FAULTY OVERBOARD EXHAUST VALVE CLOSED POSITION DEMAND. REPLACED OVERBOARD EXHAUST VALVE REF AMM 21-58-05 AND ACP''D POST INSTALLATION TEST WITH NO FURTHER FAULTS. SYSTEM NOW OK. PARTS USED: 76-2125-9-0001,QTY :1 1775851,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1775851 SN OFF 0592.
HYD C QTY LOW LIGHT APPROX 1.0 AFTER T/O. FOUND HYDRAULIC QUANTITY LOW .23 ,PERFORMED EXTERNAL GVI FOUND SIGN OF LEAKAGE ON RIGHT WHEEL WELL SUSPECT HYDRAULIC LINE T FITTING LEAKING AT RIGHT WHEEL WELL. FOUND LINE T FITTING LEAKING FROM TUBE ASSY P/ N 27274508-122 AT 12-12-01. TORQUE TOOL USED P/N 9539169. RIGHT WHEEL WELL. PERFORMED RETORQUE AS PER AMM 20-11-00-910-802, LEAK TEST PASSED AT THIS TIME, NO FOUND SIGNAL OF ANY OTHERS LEAK ALSO PERFORMED HYD C SERVICED AS PER AMM 12-12-01.
PDA 1 PANEL 436AL FOUND MISSING ON ARRIVAL AT MAD PDA PROCEDURES COMPLIED WITH. ESC NOTIFIED ADD PIC.
ENG NBR 1 OUTBOARD NACELLE STRUT ACCESS DOOR FOUND MISSING DURING WALK AROUND ENG 1 OUTBOARD NACELLE STRUT ACCESS DOOR DEFERRED IAW CDL 54D DEFERRED IAW CDL 54D MAINT PROCEDURE ACCOMPLISHED DISPATCH DESK: 64 NAME: DS, DATE: 02-JUL-23- PANEL 436AL MISSING. APPROVED CDL 54BE. PDA LOG CREATED. PLACARD REMOVED. INSTALLED NEW PANEL PER IPC 54-53-01. OK FOR SERVICE.
AD 2012-09-14 - RH SIDE STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP FOUND CRACK, PLEASE PRINT AND ACCOMPLISH EA 5340-01385 OP 004 MODIFICATION TRANSFER REF. NON-ROUTINE HX NRC WO.1721660 AND ORIGINATED BY EMP NO. V906014 FX - RH SIDE STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP REPAIRED AS PER EA 5340-01385 REV ORIG OP 004. WORK ACCOMPLISHED BY MECHANIC V920531 INSPECTED BY V925649 RII INSPECT IS OKAY. APPROVED BY HX 129272.
AD 2012-09-14 - LH SIDE STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP FOUND CRACK, PLEASE PRINT AND ACCOMPLISH EA 5340-01385 OP 003 MODIFICATION TRANSFER REF. NON-ROUTINE HX NRC WO.1721671 AND ORIGINATED BY EMP NO. V906014 FX - LH SIDE STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP REPAIRED AS PER EA 5340-01385 REV ORIG OP 003. RII INSPECT IS OKAY. APPROVED BY HX 129272. WORK ACCOMPLISHED BY MECHANIC V897546 INSPECTED BY V925649 ADD EMP:V925649
AD 2012-09-14 - RH SIDE STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP FOUND CRACK, PLEASE PRINT AND ACCOMPLISH EA 5340-01385 OP 004 MODIFICATION TRANSFER REF. NON-ROUTINE HX NRC WO.1721660. RH SIDE STA 955 REAR SPAR BULKHEAD FAILSAFE STRAP REPAIRED AS PER EA 5340-01385 REV ORIG OP 004.
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1540 BTN S38R - S39R TRANSFER REF. NON-ROUTINE HX NRC WO.1731334 . BULK CARGO COMPT - BELOW FLOOR STA 1540 BTN S38R-S39R SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATTACHED FORM 44-0008 ITEM 1 TO ITEM 7 ACCOMPLISHED. RII INSPECT IS OKAY.
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S38R - S39R TRANSFER REF. NON-ROUTINE HX NRC WO.1731326 AND ORIGINATED BY EMP NO. V896820 BULK CARGO COMPT - BELOW FLOOR SHEAR TIE AT STA 1417 BTN S38R - S39R REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1-7 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V926499 INSPECTED BY V925649 RII INSPECT IS OKAY. APPROVED BY HX 129272
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S37R - S38R TRANSFER REF. NON-ROUTINE HX NRC WO.1731329. BULK CARGO COMPT - BELOW FLOOR STA 1417 BTN S37R-S38R SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 7 ACCOMPLISHED.
AFT CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S37L - S38L TRANSFER REF. NON-ROUTINE HX NRC WO.1731314 AND ORIGINATED BY EMP NO. V896820 BULK CARGO COMPT - BELOW FLOOR STA 1417 BTN S37L - S38L SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 17 ACCOMPLISHED.
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1540 BTN S38L - S39L TRANSFER REF. NON-ROUTINE HX NRC WO.1741329 AND ORIGINATED BY EMP NO. V896820 BULK CARGO COMPT - BELOW FLOOR STA 1540 BTN S38L-S39L SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 7 ACCOMPLISHED.
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S38R - S39R TRANSFER REF. NON-ROUTINE HX NRC WO.1731326 AND ORIGINATED BY EMP NO. V896820 BULK CARGO COMPT - BELOW FLOOR SHEAR TIE AT STA 1417 BTN S38R - S39R REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1-7 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V926499 INSPECTED BY V925649 RII INSPECT IS OKAY. APPROVED BY HX 129272
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1540 BTN S38R - S39R TRANSFER REF. NON-ROUTINE HX NRC WO.1731334. BULK CARGO COMPT - BELOW FLOOR STA 1540 BTN S38R-S39R SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATTACHED FORM 44-0008 ITEM 1 TO ITEM 7 ACCOMPLISHED.
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1540 BTN S38L - S39L TRANSFER REF. NON-ROUTINE HX NRC WO.1741329. BULK CARGO COMPT - BELOW FLOOR STA 1540 BTN S38L-S39L SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 7 ACCOMPLISHED.
BULK CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S37R - S38R TRANSFER REF. NON-ROUTINE HX NRC WO.1731329. BULK CARGO COMPT - BELOW FLOOR STA 1417 BTN S37R-S38R SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 7 ACCOMPLISHED.
AFT CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S37L - S38L TRANSFER REF. NON-ROUTINE HX NRC WO.1731314 AND ORIGINATED BY EMP NO. V896820 BULK CARGO COMPT - BELOW FLOOR STA 1417 BTN S37L - S38L SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 17 ACCOMPLISHED WORK ACCOMPLISHED BY MECHANIC V926499 INSPECTED BY V925649 RII INSPECT IS OKAY. APPROVED BY HX 129272
B767-33-3-7000 EMER LT POWER SUPPLY M734 INOP TRANSFER REF. NON ROUTINE HX WO 1032718 AND ORIGINATED BY EMP V920570 M734 EMER LT POWER SUPPLY CHARGER REPLACED & TESTED NORMAL AS PER AMM 33-51-07 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V928691
RT ENG OIL TEMP REACHED AMBER BAND. #2 LUBE SCAVENGE PUMP REPLACED AND HI POWER RUNS ACCOMPLOISHED. OIL TEMPS AND PRESSURE NOTIFIED. NORMAL. NO OBSEVED INDICATION FAULTS NOTED AND NO EXISTING STATUS MESSAGES.
ON CLIMB RT ENGINE OIL TEMP APPROACHED 160. RAN QRH. REDUCED THR UST TO 40 N1. TEMP REDUCED. ACCOMPLISHED FIM 79-34 808. TROUBLESHOT TO A BAD OIL TEMP SENSOR.REPLACED #2 ENGINE TEMP SENSOR AND NO FURTHER DEFECTS NOTED REF AMM 79-34-01-424-15-H03. ALL WORK ACCOMPLIOSHED BY AERSALE MECH V931299.
L HYD QTY STS MSG L HYD PRESS WARNING LITE. SERVICED LH HYDRAULIC SYSTEM NOW READING FULL, FOUND LH ENG EDP SUPPLY LINE B NUT LOOSE. TIGHTEN UP. MOTOR ENGINE FOR 5 MINS, NO LEAK FOUND.
LE SLAT ASSYMETRY EICAS AND DISPLAY WARNNG RETURN TO GATE ACCOMPLSHED FIM 27-81-00-815-809 MSG CLEARED.SYS OPS CK ON GROUND OK. ADD EMP:U288718
BOTH UTILITES DISCONNECTED AND THE LEFT GEN UNABLE TO RESET AFTER A/C ARRIVAL, PERFORMED PRELIMINARY INSP, FOUND MSG 24-35021 ON BPCU, OPENED #1 ENG COWL AND FOUND FAN AIR VALVE COOLING DUCT WITH A HOLE IN IT ON THE BEND AND RUBBING AGAINST AND DAMAGED. THE FEEDER CABLES, ALSO TWO OF THE FEEDER CABLES ARE WORN THRU CT WHICH IS P/N 64-7831-3-0031, CORRECTION TO THE DUCT THAT WAS DAMAGED, IT IS THE PRE-COOLER DU REF WDM 24-21-11, WIRES W204-003-3/0 AND W204-004-02 ARE CHAFED INTO CONDUCTOR ON LEFT ENG 10 O''CLOCK POSITION. REQUEST MADE TO ENGINEERING FOR ECRA FOR INTERIM REPAIR. INSTALLED TEMP SPLICE PER SWP 20-10-13 AND SWP 20-30-13 AND W/D 24-21-11 W204-003-3/0 AND W204-004-02 NEEDS ENG RUN TO CHECK LEFT GEN PERFORMED #1 ENG. IDLE RUN PER AMM 7100, VERIFIED LEFT GENERATOR ON LINE, LEFT SIDE BUS TIE STAYED ENGAGED. OPS CHECK NORMAL, NO DISCREPANCIES NOTED AT THIS TIME.
#1 ENGINE INBOARD SIDE NACELLE STRUT ACCESS PANEL 436AR IS MISSING. PLACED ON CDL. CDL 54BE TOMC REJECTED DUE TO PDA 2 LOG PAGE GENERATED. CLOSED BY TOMC. PDA 2 L/P 9296893 GENERATED AND ESC ADVISED.
FWD IFE COOLING EICAS S "FORWARD COOLING SYSTEM FAN FAILURE, ACTUAL SMOKE DETECTED, IFE CARD FAILURE, OR INBOARD SHUTOFF VALVE FAILED CLOSED." FWD IFE COOLING STATUS MSG. PERFORMED IFE COOLING CIRCUIT CARD BITE PER AMM 21-58-67-404-018, NO FAULTS FOUND AT THIS TIME.
BURNING SMELL ON FLT DECK FOR SEVERAL SECONDS NOT FROM GALLEY OR AC EYE O VENTS, NO CB POPPED. O/H PEDESTAL FLOOD LIGHT ASSY FOUND TO BE OVERHEATING. LAMP ASSY WAS REPLACED. NO FURTHER NOTICE OF BURNING SMELL IN FLT DECK OR GALLEY. ACCOMPLISHED AMM 05-51-58-200-801C1. FOUND BURNING SMELL COMING OFF OF L707 AISLE STAND FLOOD LT REF SSM 33-11-01 PG 102 SHEET.
EMERGENCY LIGHT SWITCH COVER IN CLOSED POSITION TURNS EMERGENCY LIGHTS MANUALLY OFF. GUARD SWITCH WAS ON WRONG SIDE OF THE EMERGANCY LIGHT SWITCH.GUARD SWITCH NOW CORRECTLY FITTED TO CORRECT SIDE.
NR 1 PYLON NAC STA 223, MID SPAR WEB FOUND CRACKED AT IDG FEED THROUGH CUTOUT POSITION. THE SPAR WEB WAS REPLACED IAW SRM54-55-01, REPAIR 2, FIG 202.
MAJOR REPAIR, CABIN STA 1529-1535 LBL 88 FLOOR SUPPORT TEE FOUND CORRODED. SUPPORT TEE 146T0051-53 LOCAL FABRICATED REF TO LOG PAGE 9131662 (200-1102). SUPPORT TEE REPLACED AS PER SRM 51-10-02 & 51-40-02 FORM 44-0008 SHEET 5 STEP1 TO 17 ACCOMPLISHED.
BS 246, LBL 25 FLOORBEAM CORRODED. THE FLOORBEAM UPPER ANGLE REPLACED IAW SRM 51-10-02, PG 8.
ODOR OF ELECTRICAL IN COCKPIT & CABIN, .FOLLOWED BY FWD EQUIPMENT EXHAUST FAN STATUS MESSAGE. ODOR DISSAPATED. REPLACED FWD EQUIPMENT EXHAUST FAN IAW AMM 21-58-06-404-146, OPS CHECKED NORMAL.
EMERGENCY FLASHLIGHT (MISSING, NEEDS NEW BATTERY, ETC.) COCKPIT FLASHLIGHT NEEDS A NEW BATTERY. REPLACED FLASHLIGHT AND BATTERY OPS CHECK NORMAL.
OVEN 110 PRODUCING AN ELECTRICAL ODOR WHEN STARTED. REMOVED AND REPLACED THE OVEN IAW AMM 25-34-00, OPS CHECKED GOOD.
AS PER CREW, ROW 1AB EMERGENCY LIGHT INOP. PERFORMED RESERVE OF ELECTRICAL CONNECTIONS ON AISLE LIGHT ASSY L3300 REF AMM 33-51-05. PERFORMED EMERGENCY LIGHTS OP CHECK AS PER REF AMM 33-51-00. FOUND NORMAL.
EMERGENCY CEILING LIGHT INOP 36F AND 43D. RELAMPED EMERGENCY CEILING LIGHT AT POS 36F(RT) AND 43D(LT). SYS OPS CHECKED NORMAL REF AMM 33-51-04.
R2/L1 EXTERIOR EMERGENCY LIGHTS INOP. RELAMPED L1 DOOR EMERGENCY EXT LIGHT. REPLACED FUSE IN R2 DOOR EMERGENCY LIGHT PWR SUPPLY SYSTEM. OPS CHECKED NORMAL REF AMM 33-51-06.
EMERGENCY LIGHTS INOPERATIVE AT SEAT ROW 17D & 38D. REPLACED THE LAMP, OPS CHECKED GOOD.
AT FL 340 LOUD CYCLING SQUEAL FROM RT COCKPIT WINDOW AT AFT PORTION BEHIND PLASTIC COVER WITH HIGH DIFFERENTIAL PRESS. THE SOUND STOPPED DESCENDING THROUGH FL 320 & DID NOT OCCUR AGAIN DURING DIVERT AT FL 220. ACCOMPLISHED VISUAL INSPECTION OF NR 2 & 3 RT WINDOW IAW 56-11-02-706-001. ACCOMPLISHED PRESS CHECK IAW 05-51-24-782-221-001, FOUND ONLY PLASTIC PROTECTION SHEET STUCK IN UPPER LT CORNER OF NR 3 RT WINDOW. CLEANED NR 2 & 3 WINDOW SEALS & TORQUED NR 2 RT IAW 56-11-10-004-001 & AGAIN ACCOMPLISHED PRESS CHECK TO 4 PSID. NO LEAKS DETECTED OUTSIDE.
EMERGENCY EXIT LIGHTS AT SEAT ROWS 4 & 5 ARE INOPERATIVE. RESEATED EEPL CONNECTOR ON SEAT ROW 6 IAW WDM 33-51-18. EMER LIGHTS CHECKED GOOD IAW AMM 33-51-00-715-001.
SUPPORT TASK R4 DOOR ABOVE ATTENDANTS SEAT EXIT SIGN FOUND DIM. R4 DOOR ATTENDANTS SEAT BATTERY REPLACED & EMER LIGHT TEST FOUND NORMAL IAW AMM 33-51-01.
HYDRAULIC PRESSURE LOW, COMPLIED WITH UNABLE TO EXTEND T/E FLAPS BEYOND 5. L/E SLAT DISAGREE T/E FLAP DISAGREE, R & R LT, INBD (CTR HYD SYS) ELEVATOR ACTUATOR, L/E SLAT INBD MOTOR & T/E FLAP PDU ELECTRIC MOTOR, OPS CHECKED GOOD.
CABIN BS 325 RBL 22-33 FLOORBEAM CORRODED. BS 325 RBL 13 TO RBL 35 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 21 AND HFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 21 ACCOMPLISHED.
CABIN BS 325 LBL 52 TO 57 FLOORBEAM CORRODED. CABIN BS 325 LBL 45" TO LBL 61" FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 21 ACCOMPLISHED.
CABIN BS 3043 LBL 20 TO 35 FLOORBEAM CORRODED. CABIN BS 303 LBL 20 TO LBL 35 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 24 ACCOMPLISHED.
BS 325 LBL 88 LONGITUDINAL FLOOR SUPPORT CORRODED. CABIN BS 325 LBL 88 LONGITUDINAL FLOOR SUPPORT REPAIRED AS PER ECRA 5310-05464 REV HFEC NIL CRACK FOUND ATTACH MAINTAINED WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 3 ACCOMPLISHED.
CABIN: BS 1614 LBL 50 AND RBL 50 GALLEY TIE DOWN FITTING CORRODED. CABIN BS 1614 LBL 50 AND RBL 50 TIE DOWN FITTINGS REPLACED AS PER AMM 25-31-04 AND SRM 51-40-04 (2EA).
CABIN: BS 1592 LBL 15 AND LBL 50 GALLEY TIE DOWN FITTING CORRODED. CABIN BS 1592 LBL 15 AND LBL 50 GALLEY TIE DOWN FITTINGS REPLACED AS PER AMM 25-31-04 AND SRM 51-40-04 (2EA).
WITH FLAPS UP AT 230 KNTS APPROXIMATELY 15 MINUTES PRIOR TO LANDING THE L/E SLAT ASYM EICAS MESSAGE ILLUMINATED, DECLARED AN EMERGENCY AND COMPLIED WITH QRH. INSPECTED L/E SLATS & T/E FLAPS, NO DEFECTS NOTED, FOUND MSG 27 -81021 ON PSEU, PERFORMED PSEU BITE, NO DEFECTS NOTED, ALL SENS ORS & TARGETS NORMAL, T/S PER FIM 27-81-00-101, CYCLED L/E ALTN ARM SWITCH, MSG ERASED, CYCLED FLAPS & SLATS NUMEROUS TIMES, NO DEFECTS NOTED, NO FAULTS ON PSEU OR FSEU, OPS CHECKS GOOD.
PASSENGER OXYGEN PSU MANUAL DEPLOY TEST FAILED OXYGEN CONT MANUAL DEPLOY TIME DELAY RELAY K466 REPLACED AND OXYGEN PSU MANUAL DEPLOY OPERATION TEST CARRIED OUT NORMAL REF AMM 35-21-00.
SMELL ODOR OF BURNING PLASTIC AT ROWS 18ABC AND SEAT 24AB. ENTERTAINMENT UNIT BELOW SEAT 18C FOUND TO BE WARMER HOTTER THAN THE OTHER UNITS ADJACENT TO IT. SHUTDOWN ENTERTAINMENT SYSTEM AS A RESULT. COULD NOT VERIFY FAULT. SMELL ODOR ACTUALLY ORIGINATED AT SEAT ROW 18DEF. ALL IFE FUNCTION NORMAL AT 18DEF AMP 24AB. REQUEST FROM PANASONIC ENG R AMP R D SEAT HARNESS, HANDSETS, CRADLES, RJUS AMP SEAT BOX IAW AMM 23-32-00. ALL IFE FUNCTIONS NORMAL AT SEAT 18DEF.
DOOR L4 OUTSIDE EMERGENCY LIGHT INOPERATIVE. FOUND LIGHT SOCKET WITH CORROSION, CLEANED SOCKET CHECKS GOOD PER AMM 33-51-00.
EMERGENCY CEILING LIGHT AT ROWS 2 AB INOPERATIVE. FOUND CONNECTION LOOSE ON CEILING EMERGENCY LIGHT AT ROW 2 A, B GROUND, CHECKS GOOD PER AMM 33-51-00.
THE EMERGENCY LIGHTS AT ROWS 18-21DEF WERE FOUND INOPERATIVE. THE BATTERY AND CHARGER WERE REPLACED IAW MM 33-51-07, PAGE 201.
INSPECTION FOUND FLOORBEAM CORRODED AT BS 325, LBL 54. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIGURE 201.
INSPECTION FOUND FLOORBEAM CORRODED AT BS 303, LBL 30. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIGURE 201.
INSPECTION FOUND FLOORBEAM CORRODED AT BS 303, LBL 30. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIGURE 201.
INSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 303-325, LBL 30. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-10-02, PAGE 8.
THE EMERGENCY LIGHT BATTERY FAILED TEST PER W/C 64-3350-1-3800. THE BATTERY PACK AND CHARGER WERE REMOVED AND REPLACED IAW MM 33-51-07.
SMOKE WITH ELECTRICAL ODOR APPEARED IN CABIN SHORTLY AFTER TAKEOFF. ELECTRICAL SPARKING IN CEILING AREA FORWARD OF L-3 DOOR. LIGHTS & NSFSB SIGNS FLICKERED & PA SPEAKERS CRACKLED. HALON FIRE EXTINGUISHER WAS USED ON OVERHEAD AREA OF FORWARD CENTER LAV J. LANDED WITHOUT FURTHER PROBLEMS. PANEL ABOVE LAV-J OPENED FOR INSPECTION. MX FOUND A BURNT WIRING HARNESS AT A SUPPORTING CLAMP WITH EVIDENCE OF HEAT DAMAGE ON SURROUNDING STRUCTURE. THE W1276 HARNESS INCORPORATED WIRING FOR LAV HOT WATER HEATER, SPEAKERS & LIGHTS. WIRE BUNDLE WAS CHAFING ON EDGE OF HONEYCOMB WALL PANEL. WIRING HARNESS WAS REPAIRED & CLAMP SECURED. AN FCD WAS ISSUED TO INSPECT THE REMAINDER OF THE FLEET.
THE EMERGENCY LIGHTS ON PASSENGER SEATS ROW 23-28 LT AND RT SIDE WERE FOUND INOPERATIVE. INSPECTION FOUND LOOSE CONNECTOR AT SEAT 22D AND BLOWN FUSE IN POWER SUPPLY FOR EMERGENCY LIGHTS AT STA 785 RT SIDE. SECURED LOOSE CONNECTOR AND REPLACED POWER SUPPLY.