N669AB

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

3 reports on file, 2019-03-30 – 2019-03-31.

SMOKE/FUMES/ODORS/SPARKS · 2019-03-31 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 1) · airframe 36,409 hrs · 32,288 cycles

PDIS 669 21-01 1929651 31MAR19 TYS ASSGN ABNORMAL ODOR PRESSENT ON FLT DECK WITH PACK 1 ON, N O ODOR IN CABIN 24934 00 EK HISTORY: YES MEL 31MAR19 15:45 TYS C09011 21-13-2 AIR CONDITIONING PACKS

Source: SDR HNAA2019040100086
SMOKE/FUMES/ODORS/SPARKS · 2019-03-31 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 36,409 hrs · 32,288 cycles

MDIS 669 21-01 1929643 31MAR19 TYS CLOSE TROUBLESHOT ELECTRICAL ODOR REF. LOG PAGE 192964 SEQ 2 FACT 31MAR19 01:24 TYS VISUALLY INSPECTED FLIGHT COMPARTMENT RELAYS AS WELL AS POWER DISTRIBUTION RELAYS NO OBVIOUS DEFECTS OR BURN ODORS NOTED. REMOVED AND INSPECTED FA FWD HANDS ET FOUND NO OBVIOUS DEFECTS. CONTINUE DISCREPANCY LOG PAGE 192964 SEQ 2.

Source: SDR HNAA2019040100085
SMOKE/FUMES/ODORS/SPARKS · 2019-03-30 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 36,403 hrs · 32,281 cycles

PDIS 669 21-01 1929642 30MAR19 TYS CLOSE DURING CLIMBOUT AT 22000 FT, NOTICED ELECTRICAL ODOR IN FLIGHT COMPARTMENT, SMELL DISSAPATED AFTER REACH ING PAGE S-8 ON QRH. FACT 31MAR19 12:01 TYS INSP.'D LEFT AND RIGHT RELAY PANELS AND POWER DIST. BOX'S. NO DEFECTS. LOWERED AND INSP'D BACKSIDE OF OVERHEAD CB PANEL. NO DEFECTS NOTED. REINSTALLED PANEL.INSP'D RECIRC FAN UNDER CABIN FLOOR AT ROW 10. NO DEFECTS FOUND. REINSTALLED FLOOR PANEL. GROUND RAN APU & ENG'S W/BLEEDS, PACKS, FAN ON & OFF TOGETHER & INDEPENTLY. NO ODOR DETECTED. OK FOR SERVICE

Source: SDR HNAA2019040100084