N677AZ

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

4 reports on file, 2026-09-13 – 2026-10-26.

FALSE WARNING · 2026-10-26 Matched by certificate designator
ATA 2612

Part: WARNING MESSAGE — FALSE ACTIVATION (ZONE 400) · airframe 13,099 hrs · 2,184 cycles

ON ENG SHUTDOWN, RECIEVED STATUS MESSAGE RT ENG FIRE LOOP 1. PERFORMED FIM 26-11 FT 804. NO FAULTS FOUND. ACFT OK FOR SERVICE ACFT REMAINS NO ETOPS.

Source: SDR ABXA20261026485
FALSE WARNING · 2026-09-16 Matched by certificate designator
ATA 2611

Part: WARNING MESSAGE — FALSE INDICATION (NR 1 FIRE LOOP) · airframe 12,853 hrs · 2,090 cycles

LEFT ENG FIRE LP 1 STATUS MESSAGE CAME ON AFTER SHUTDOWN. PERFORMED ENGINE FIRE DETECTION SYSTEM OPERATIONAL TEST IAW AMM 26-11-715-001. TEST SUCCESSFUL MESSAGE CLEARED NO FURTHER DEFECTS NOTED. A/C REMAINS NO ETOPS AND RETURNED TO SERVICE.

Source: SDR ABXA20260916411
WARNING INDICATION · 2026-09-13 Matched by certificate designator
ATA 2612

Part: FIRE LOOP — FAULTED (ZONE 400) · airframe 12,834 hrs · 2,083 cycles

AFTER PRESSURIZE FOR PUSH "R ENG FIRE LP 1" STATUS MSG ILLUMINATED. PERFORMED ENG FIRE LOOP TEST IAW AMM 26-11-00 WITH NO ISSUES NOTED. NO PRESENT EICAS MSG. A/C REMAINS NO ETOPS. A/C RETURNED TO SERVICE.

Source: SDR ABXA20260913405
OTHER · 2026-09-13 Matched by certificate designator
ATA 2150

Part: A/C PACK — NO DISCREPANCY (ZONE 100) · airframe 12,835 hrs · 2,084 cycles

AFTER DOOR SHUT, SAW SMOKE AT L & R PACK VENTS W/ BURNING ODOR. FOUND NO BURNING ODOR AND RAN THE PACKS AND NO SMOKE FOUND TO BE CONDENSATION FROM PACKS IAW AMM 21-00-00 A/C REMAINS NO ETOPS. A/C RETURNED TO SERVICE.

Source: SDR ABXA20260913406