N677UA

BOEING 767-322 · 2001 · Fixed-wing multi-engine · 2 engines · 330 seats · Valid Registration

Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

331 reports on file, 2002-01-16 – 2026-10-28.

OTHER · 2026-10-28 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 90,092 hrs · 16,886 cycles

CEILING EMERGENCY LIGHT AT SEAT 7L, NOT WORKING, LAMP REPLACED NO FIX. REPLACED LIGHT ASSY IAW AMM 33-51-04. OPS CHKD GOOD.

Source: SDR CALA2026102920639
SMOKE/FUMES/ODORS/SPARKS · 2026-09-28 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 89,768 hrs · 16,844 cycles

STRONG BURNING PLASTIC ODOR COMING FROM AFT RIGHT LAV, WHEN LAV DOOR CLOSED AND LOCKED. PERFORMED CONDITIONAL INSPECTION IN AFT RT LAVS. VISUALLY INSPECTED LAVS M & K WHILE DOORS ARE LATCHED CLOSED, NO ODOR, NO BURNING NOTED, IAW AMM 05-51-56-940-801-C1.

Source: SDR CALA2026092919971
SMOKE/FUMES/ODORS/SPARKS · 2026-09-12 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 89,636 hrs · 16,827 cycles

HIGH HEAT ODOR ON CLIMB FO SIDE HAD ELECTRICAL BURNING ODOR SEVERAL TIMES IN CLIMB & CREW REPORTED FLIGHT DECK WAS COOL BEFORE TAKEOFF. DURING CLIMB NOTICED FWD INSTRUMENT PANEL WAS VERY HOT BUT PACK ON FULL COLD & WAS BLOWING COLD AIR. HOTTER ON FO SIDE THAN CAPT SIDE. FO NOTICED ELECTRICAL BURNING ODOR FROM GEAR HANDLE. PERFORMED GVI OF FWD & MAIN E/E BAY & FOUND NO OBVIOUS EVIDENCE OF FIRE OR BURNING. NO ODOR IN EITHER E/E BAY. REMOVED UPPER EICAS DISPLAY, FOUND EQPT COOLING AIR WARMER THAN NORMAL. INSTALLED UPPER EICAS DISPLAY IAW AMM 31-41-01. SUSPECT EQPT COOLING ISSUE. PERFORMED CONDITIONAL INSP OF ODOR IAW AMM 05-51-56-940-801-C1. RAN PACKS FOR LONG DURATION & CYCLED FLT DECK TEMP MULTIPLE TIMES, NO ODOR NOTED. PERFORMED INSP BEHIND BOTH NAV SCREENS FOR LOOSE DUCTING & WIRING. NO FAULTS NOTED. INSPD FWD & CENTER E/E FOR SIGNS OF ELECT BURNING ODOR, & LOOSE DUCTING, NO FAULTS NOTED. CYCLED EQUIPMENT COOLING SWITCH IN DIFFERENT MODES FOR SIGNS ODOR. NO ODOR NOTED. ALL C/B VERIFIED CLOSED PRIOR TO INSPECTION. DUE TO ODOR FORM 46-6020, FLIGHT CREW REPORT ODOR AND HIGH HEAT COMING FROM MCP. WILL REPLACE AS PRECAUTIONARY. EICAS DISPLAYS WERE ALSO INSPECTED FOR LOOSE DUCTING AND ANY BURNT CONNECTIONS. NO PERFORMED TESTS 4 & 30 PER AMM 22-00-02-742-006-001. NO FAULTS FOUND DURING TESTS. RETURNING A/C TO FULL CAT STATUS. OK TO CONTINUE.

Source: SDR CALA2026091419388
OTHER · 2026-04-11 Matched by certificate designator
ATA 2561

Part: LIFE VEST — MISSING (ZONE 200) · airframe 87,797 hrs · 16,587 cycles

LIFE VEST CHECK. 1L ADULT LIFE VEST MISSING. NEW LIFE VEST INSTALLED IAW DWG 2560DD15305 & AMM 25-62-99-900-801.

Source: SDR CALA2026041315294
OTHER · 2026-03-31 Matched by certificate designator
ATA 5730

Part: ACCESS DOOR — MISSING (ZONE 500) · airframe 87,634 hrs · 16,564 cycles

LEFT WING LEADING EDGE SLAT MECHANISM ACCESS DOOR MISSING. PANEL 521WB. PANEL 521WB REPLACED I.A.W AMM TASK 57-41-01-400-801. LOOSE ARTICAL CHECK CARRIED OUT BEFORE PANEL FITTMENT. PARTS DEPARTING LOGPAGE CREATED.PARTS USED: 76-5741-3-0002,QTY :1

Source: SDR CALA2026040115004
SMOKE/FUMES/ODORS/SPARKS · 2026-02-26 Matched by certificate designator
ATA 2120

Part: FILTER — DIRTY (ZONE 100) · airframe 87,241 hrs · 16,512 cycles

AFTER ENGINE START AND WHEN THE PACKS WERE PLACED ON, WE GOT A CALL FROM THE CABIN THAT PAX SMELLED STRONG FUEL/ENGINE EXAUST SMELL AND WERE HAVING A HARD TIME BREATHING. PLACE PACKS ON APU BLEED AND THEN THE CABIN REPORTED THAT THE SMELL WENT AWAY. FLAGGING SDR TROUBLE SHOOTING CARRIED OUT IAW AMM 05-51-56-940-801-C1 FUME/ODOUR EVENT CONDITIONAL INSPECTIONS. INSPECTIONS COMPLETE REF LP 8048700. NIL FAULTS/ODOURS DETECTED DURING ALL TESTING. BOTH ENGINES AND APU RAN USING BOTH PACKS. NO FAULTS FOUND. RECICULATION FILTERS REPLACED AS PRECAUTION REF LP 8050313. UPON CONSULTATION WITH TOMC PP AC RELEASED BACK TO SERVICE.

Source: SDR CALA2026030214133
Earlier reports · 2002–2025 · 325 reports

2025

OTHER · 2025-11-24 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (ZONE 200) · airframe 86,194 hrs · 16,372 cycles

DOOR 4L ESCAPE SLIDE LIGHT INOP RELAMPED DOOR 4L (AFT MOST LEFT DOOR) PER AMM 33-51-06-902-082. OPS CHECKS GOOD.

Source: SDR CALA2025112811546
OTHER · 2025-11-09 Matched by certificate designator
ATA 3397

Part: ELEC CONNECTOR — DAMAGED (ZONE 200) · airframe 86,023 hrs · 16,348 cycles

EMERGENCY LIGHTS FROM ROW 37 TO 43 DO NOT ILLUMINATE, CONFIRMED FAULT. REPAIRED CONNECTOR AT 37D REF SWPM 20-42-01. EMG PATHWAY LIGHTS OP CHK GOOD.

Source: SDR CALA2025110911016
NO TEST · 2025-09-30 Matched by certificate designator
ATA 3397

Part: ELEC CONNECTOR — DAMAGED (ZONE 200) · airframe 85,600 hrs · 16,291 cycles

EMERGENCY LIGHT ABOVE SEAT 7L INOP CONNECTOR BROKEN ON AIRCRAFT SIDE AND LENS MISSING CONNECTOR REPLACED AS PER SWPM 20-63-03, LENS BEZEL REPLACED IAW AMM 33-51-05-002-039. OPERATIONAL TEST CARRIED OUT IAW AMM 33-51-00-715-001-001 WITH RESULT GOOD.

Source: SDR CALA2025093009477
SMOKE/FUMES/ODORS/SPARKS · 2025-07-27 Matched by certificate designator
ATA 2120

Part: TIRE — ODOR (CABIN) · airframe 84,895 hrs · 16,197 cycles

BURNT RUBBER SMELL AT TOUCHDOWN AT 1L AND 1R FROM FLT ATTENDANT. AREA AROUND DOORS 1L AND 1R INSPECTED, NO VISIBLE SIGNS OF DAMAGE, LEAKAGE OR OVEHEATING. WHEELS AND BRAKES INSPECTED WITH NO FAULTS FOUND, SMELL LIKELY DUE TO NORMAL TIRE/BRAKE HEATING ON LANDING. ALL SYSTEMS NORMAL.

Source: SDR CALA2025073007092
OTHER · 2025-07-15 Matched by certificate designator
ATA 3350

Part: CHARGER — FAULTED (ZONE 200) · airframe 84,756 hrs · 16,177 cycles

ON ARRIVAL FOUND DOOR 1L & 1R INTERNAL EMERGENCY EXIT LIGHTS ILLUMINATED WITH EMERGENCY LIGHT SWITCH IN OFF POSITION R&R BATTERY CHARGER ASSY AND BATTERY PACK AS PER AMM 33-51-07. OPS TESTED OKAY AND LIGHT TESTS OKAY. DEFECT CLEARED.

Source: SDR CALA2025071606621
WARNING INDICATION · 2025-03-17 Matched by certificate designator
ATA 2800

Part: TRANSFER SYS — NO DISCREPANCY · airframe 83,318 hrs · 15,986 cycles

FUEL IMBALANCE OF 2800 LBS INFLIGHT. R WING LOW . AFTER BRIEFING WITH THE FLIGHT CREW WE WERE ABLE TO DETERMINE THAT THE FUEL XFEED SYSTEM WORKS AS EXPECTED AND THE INBALANCE WAS PLACED UNDER CONTROL BY NORMAL MANAGEMENT OF THE XFEED SYSTEM VALVES. OPERATIONAL TEST OF THE ENGINE FUEL CROSSFEED VALVE CARRIED OUT PER AMM TASK 28-22-00-715-128. TEST OK.

Source: SDR CALA2025031902944
FALSE WARNING · 2025-02-24 Matched by certificate designator
ATA 3414

Part: INDICATOR — FAULTED (AIRSPEED) · airframe 83,078 hrs · 15,954 cycles

ON DEPARTURE ROLL AIRSPEED DESCREPENCY OF 40 KTS LOG PAGE CLEARED IN REFERNCE TO LOG PAGE 3978826. SEE FORMENTIONED LOG PAGE FOR UPDATED DETAILS. DURING INSPECTION IT WAS NOTED THAT F/O AIRSPEED INDICATOR, TRACKED UP AND DOWN ON MECHANICAL DIGITS, DURING STATIONARY INDICATION AND FAILED TEST, ALSO TRACKED UP AND DOWN USING ALT SYSTEM. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1652315 SN OFF 9591 INDICATOR, MACH OFF 75-3111-9-0001 9591 ON 75-3111-9-0001 0008 F/O AIRSPEED INDICATOR R/R IAW AMM 34-13-02-404-003 WHICH INCLUDED OPERATIONAL TEDT OF AIR DATA COMPUTING SYSTEM REF AMM 34-12-00-715-001, STSTEM OP CHECK SATIS. AIRCRAFT SYSTEM SERVICIBLE FOR FURTHER FLIGHT.

Source: SDR CALA2025022702503
NO TEST · 2025-02-21 Matched by certificate designator
ATA 3397

Part: ELEC CONNECTOR — DAMAGED (ZONE 200) · airframe 83,057 hrs · 15,951 cycles

EMERGENCY LIGHTS OPERATIONAL CHECK - EMERG FLOOR PROXIMITY LIGHTING SEAT 40FED - 43FED NOT COMING ON DURING LIGHT TEST TROUBLE SHOOTING CARRIED OUT, SUSPECT EMERG BATTERY POWER SUPPLY . R/R IAW AMM 33-51-07-002-006. FAULT NOT FIXED. REINSTALLED ORIGINAL POWER SUPPLY BOX WITH BATTERY. FURTHER TROUBLE SHOOTING CARRIED REF WDM 33-51-15 PG 3, FOUND ON CONNECTOR D9194 WIRE 4NS097-2035, HAD PULLED WIRES FROM CONNECTOR D9194, UNDER SEAT 44E. REQUIRES REINSTALLATION, WITH NEW PINS AND CONNECTOR REF SWPM. : WIRE NO/ CONNECTOR NO/ WDM SWDP WIRE HAS BEEN BAGGED UP UNDER SEAT 44E, SUSPECT BERNEDY CONNECTOR PN B9787-001 REQ & PINS REQ FOR JOB PN NEEDS TO BE INVESTIGATED REF SWPM 20-86-00 CABLE UNDER 44D FOUND DISCONECTED FROM ELECTRICAL CONNECTOR. NEW CABLE FITTED AS PER AIPC 23-34-51-76 AND WDM 33-51-15-1. EMERGENCY LIGHTS TEST CARRIED OUT; LIGHTS NOW OPERATE CORRECTLY.

Source: SDR CALA2025022402420
WARNING INDICATION · 2025-02-15 Matched by certificate designator
ATA 3010

Part: ANTI-ICE VALVE — FAULTED (ZONE 500) · airframe 83,030 hrs · 15,947 cycles

L WING ANTI ICE VALVE INOP PERFORMED LH WING ANTI ICE VALVE REMOVAL UP TO AND INCLUDING STEP 2D(3) IAW AMM 30-11-02-004-001. REMOVED AND REPLACED ANTI-ICE VALVE, WING LE DUCT ON L/H IAW AMM 30-11-02-404-012. COMPETED STEPS FROM A UP TO INCLUDED E(13) PARTS USED: 1579681,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1579681 SN OFF 1880 IPC REFERENCE # 30-11-00-01 CONTINUED WITH STEP 3E.14 OF AMM 30-11-02-404-012 UPTO COMPLETION. OPS CHECK GOOD. PREVIOUS TECH MIXED UP SN OFF AND NEW PART. REF PICS. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1579681 SN OFF 1151 VALVE, ANTI-ICE OFF 75-3013-9-9001 1151 ON 75-3013-9-9001 1880

Source: SDR CALA2025021802356

2024

OTHER · 2024-12-25 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 200) · airframe 82,563 hrs · 15,881 cycles

CABIN STA 303 LBL 37 TO LBL 56 FLR STRUCTURE FOUND CORRODED.

Source: SDR CALA2024122703168
OTHER · 2024-12-25 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — DAMAGED (ZONE 200) · airframe 82,563 hrs · 15,881 cycles

REFER WO.4105436 FLOORBEAM SUPPORT CLIP P/N 141T5134-38 NIL STOCK, LOCAL FABRICATE PER HX R1-53-00-17302 REV A ITEM 2. CABIN STA 303 FLOORBEAM SUPPORT CLIP P/N: 141T5134-38 FABRICATE AS PER ECRA 5310-08477 REV A ATTACHED FORM 44-0008 ITEM 1-7.

Source: SDR CALA2024122703173
OTHER · 2024-12-25 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — DAMAGED (ZONE 200) · airframe 82,563 hrs · 15,881 cycles

FLOORBEAM SUPPORT CLIP PN: 141T5134-28 NIL STOCK, LOCAL FABRICATE PER HX R1-53-00-17302 REV A ITEM 1. CABIN STA 303 FLOORBEAM SUPPORT CLIP P/N: 141T5134-28 LOCL FABRICATED AS PER ECRA 5310-08477 REV - ATTACHED FORM 44-0008 1-7.

Source: SDR CALA2024122703174
OTHER · 2024-12-25 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 200) · airframe 82,563 hrs · 15,881 cycles

CABIN STA 325 LBL 43 TO LBL 55 FLR STRUCTURE FOUND CORRODED. CABIN STA 325 LBL 43 TO LBL 55 FLOORBEAM UPPER CHORD PERMANENT REPAIRED AS PER SRM 53-00-51-2R-4 REPAIR 4 FIG 201. ATTACHED FORM 44-0008 ITEM 1-23.

Source: SDR CALA2024122603167
OTHER · 2024-12-25 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — DAMAGED (ZONE 200) · airframe 82,563 hrs · 15,881 cycles

REFER WO.4105436 SUPPORT CLIP PN: 141T5178-463 NIL STOCK, LOCAL FABRICATE PER HX R1-53-00-17302 REV A ITEM 3. CABIN STA 303 FLOOR BEAM SUPPORT CLIP P/N: 141T5178-463 FABRICAT E AS PER ECRA 5310-08477 REV - ATTACHED FORM 44-0008 ITEM 1-7.

Source: SDR CALA2024122703169
FALSE WARNING · 2024-11-12 Matched by certificate designator
ATA 5270

Part: SENSOR — FALSE INDICATION (ZONE 800) · airframe 82,551 hrs · 15,880 cycles

FWD ACCESS DOOR CAUTION REMAINS ON WITH DOOR CLO SED. APPLY MEL DOOR VERIFIED CLOSED APPROVED COMPLIED WITH MEL DOOR VERIFIED CLOSED AND LATCHED *DM* REF DOOR WARNING SENSOR TEST - ACCESS DOORS TASK 52-71-00-865-081.DOOR WARNING SENSOR (S0200) P/N 284T0484-2 AND DOOR WARNING SENSOR (S0201) P/N 8-345-03 ADDED TO M&L IN CASE NEEDED

Source: SDR CALA2024111401138
WARNING INDICATION · 2024-08-25 Matched by certificate designator
ATA 3510

Part: OXYGEN MASK — LEAKING (ZONE 200) · airframe 81,589 hrs · 15,749 cycles

IN CRUISE ABOVE FL300 OXY LEAK BEHIND P6 PANEL TEST GOOD ON GROUND TEST BAD IN FLIGHT MXP147. ALSO SUGGEST REPLACING CLOTH BRADED LINE THAT GOES FROM BEHIND O2 MASK BOX TO TEE AS PRECAUTIONARY. CREW STATED THAT O2 WAS READING 1790 PSI BEFORE FLIGHT. WHEN BRIEFLY INSPECTED AREA THAT CREW STATED THEY HEARD AN AIR LEAK. FLIGHT LANDED CREW O2 IS NOW READING 1460 PSI. NO OBVIOUS LEAKS NOTED. R & R 2ND OBSERVER MASK IAW AMM 35-11-51-004-059. ALSO REMOVED OXYGEN MASK STOWAGE BOX IAW AMM 35-11-51-004-002. OPS & LEAK CHECK GOOD. OXYGEN HAS BEEN STEADY AT 1480 SINCE PLANE HAS BEEN ON THE GROUND.

Source: SDR CALA2024082602277
NO TEST · 2024-08-22 Matched by certificate designator
ATA 3350

Part: LAMP — FAULTY (ZONE 200) · airframe 81,558 hrs · 15,744 cycles

EMERGENCY LIGHTS OPERATIONAL CHECK {B767-33-3-7000} - DR #2 L/H EMERGENCY LIGHT INOPERATIVE. DR#2 RH EMERGENCY LIGHT REPLAMPED AS PER AMM 33-51-06-902-082. EMERGENCY LAMP NOW OPERATIVE. SATISFACTORY FOR CONTINUED SERVICE.

Source: SDR CALA2024082300484
OTHER · 2024-08-09 Matched by certificate designator
ATA 5512

Part: SKIN — CORRODED (HORIZONTAL STAB) · airframe 81,409 hrs · 15,721 cycles

WHILE WORKING HSTA WORK CARD, OBSERVED CORROSION/BULGING ON THE UPPER SKIN ON THE HORIZONTAL STABILIZER CENTER MAIN STRUCTURE. TRANSCRIBED FROM HAECO GSO NRC 9286005. 08-AUG-2026. PER ECRA 5512-01030 PART 1 INTERIM REPAIR ITEM 2 CREATE LOG PAGE TO PERFORM INSPECTION PER PART 2 OF ECRA 5512-01030 ON OR BEFORE REF ECRA 5512-01030, "PERFORM INSPECTIONS PER PART 2 OF ECRA TOMC-APPROVAL FROM SC1ELBYC COMMENT 5512-01030 ON OR BEFORE 08-AUG-2026." CHECK EC-RA5512-01030 PART 1 STEP 2 INSPECTION REQUIRED BEFORE 08-AUG-2026. "PERFORM INSPECTIONS PER PART 2 OF ECRA 5512-01030 ON OR BEFORE QC RECORDS UPDATE 08/AUG/2026". QC REVIEWED T/A: ON OR BEFORE 08AUG26....LN/U253409 REF PLN/ENG LP 8877531

Source: SDR CALA2024081202191
SMOKE/FUMES/ODORS/SPARKS · 2024-07-27 Matched by certificate designator
ATA 2121

Part: BEARING — FAILED (RECIRC FAN) · airframe 81,393 hrs · 15,718 cycles

POWER IDLE SMELL FROM INOP RECIRC FAN INCREASE ON FLIGHT DECK/CA BIN CABIN ODOR FORM PHOTOS BONDING RESISTANCE CHECK MEASURES .00297 OHMS, WITHIN LIMITS. REF AMM TASK 21-25-01-404-019. PERFORMED INSPECTION FOR ODOR IN FLIGHT DECK/CABIN IN ACCORDANCE AMM 5-51-56-940-801-C1. DETERMINED CAUSE OF ODOR TO BE FAILED RIGHT RECIRCULATION FAN (BEARINGS FAILED IN FAN CAUSING BLADES TO INTERFERE WITH FAN CASE). CONTACTED TOMC (ED) AND CONFIRMED NO FURTHER INVESTIGATION OR BURNOUT NEEDED AFTER FAN REPLACEMENT. REMOVED AND REPLACED RH RECIRC FAN IAW AMM 21-25-01. OPS CHK NORMAL.

Source: SDR CALA2024072900299
SMOKE/FUMES/ODORS/SPARKS · 2024-06-20 Matched by certificate designator
ATA 2530

Part: CONTROL UNIT — UNKNOWN (OVEN) · airframe 80,997 hrs · 15,661 cycles

ALL REAR GALLEY OVEN CIRCUIT BREAKERS POPPED DURING CLIMBOUT SETTING SDR FLAG. INSPECTED BEHIND CB PANEL NO SIGN OF ARCING OR ANY FAULTS T/S PER SSM 25-31-02-102, NO FAULTS FOUND, REMOVED AND REPLACED BOTH RIGHT ELCU S AS PRECAUTIONARY, REF AMM 25-31-03-404-009. OPS CHECK GOOD. PARTS USED: 1563980,QTY :1 PARTS USED: 1563980,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1563980 SN OFF 3491 IPC REFERENCE # 2531102 CONTROL, LOAD, OFF 99-2531-9-0002 3491 ON 99-2531-9-0002 6664

Source: SDR CALA2024062000030
NO TEST · 2024-05-05 Matched by certificate designator
ATA 3350

Part: LAMP — NO TEST (EMERGENCY LIGHT) · airframe 80,445 hrs · 15,586 cycles

EMERGENCY LIGHTS OPERATIONAL CHECK {B767-33-3-7000} - DOOR 1 RIGHT SLIDE EMERGENCY LIGHT U/S DOOR 1 RIGHT SLIDE EMERGENCY LIGHT LAMP REPLACED AS PER AMM 33-51-06-902-082, TESTED OK PARTS USED: 99-3351-3-0014,QTY :1

Source: SDR CALA2024050601316
NO TEST · 2024-05-05 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CAIBN) · airframe 80,445 hrs · 15,586 cycles

REF LOGPAGE 7867179 - (DOOR 1 LEFT SLIDE EMERGENCY LIGHT U/S) TO REPORT AS SDR DOOR 1 LEFT SLIDE EMERGENCY LIGHT LAMP REPLACED AS PER AMM 33-51-06-902-082. TESTED OK

Source: SDR CALA2024050601319
OTHER · 2024-05-05 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 80,490 hrs · 15,592 cycles

REF LOG PAGE 7867224 - (LEFT MID TYPE 1 SLIDE EXIT EMERGENCY LIGHT U/S) TO REPORT AS SDR LEFT MID TYPE 1 SLIDE EXIT EMERGENCY LIGHT LAMP REPLACED AS PER AMM 33-51-06-902-082, TESTED OK. LEFT MID TYPE 1 SLIDE EXIT EMERGENCY LIGHT LAMP REPLACED AS PER AMM 33-51-06-902-082, TESTED OK PARTS USED: 99-3351-3-0014,QTY :1

Source: SDR CALA2024050801390
NO TEST · 2024-05-05 Matched by certificate designator
ATA 3350

Part: LAMP — NO TEST (EMERGENCY LIGHT) · airframe 80,445 hrs · 15,586 cycles

REF LOGPAGE 7867184 - (DOOR 2 LEFT SLIDE EMERGENCY LIGHT U/S) TO REPORT AS SDR DOOR 2 LEFT SLIDE EMERGENCY LIGHT LAMP REPLACED AS PER AMM 33-51-06-902-082, TESTED OK

Source: SDR CALA2024050601318
NO TEST · 2024-05-05 Matched by certificate designator
ATA 3350

Part: LAMP — NO TEST (EMERGENCY LIGHT) · airframe 80,445 hrs · 15,586 cycles

EMERGENCY LIGHTS OPERATIONAL CHECK {B767-33-3-7000} - LEFT MID TYPE 1 SLIDE EXIT EMERGENCY LIGHT U/S (ABOVE AFT WING TO BODY FAIRING) LEFT MID TYPE 1 SLIDE EXIT EMERGENCY LIGHT LAMP REPLACED AS PER AMM 33-51-06-902-082, TESTED OK.

Source: SDR CALA2024050601317

2023

OTHER · 2023-10-19 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 78,478 hrs · 15,323 cycles

DOOR L1 EXTERNAL EMERGENCY LIGHT INOP. M736 CHARGER UNIT AND BATTERY REPLACED IAW AMM 33-51-07. ALL OPS NOW SATISFACTORY. PARTS USED: 99-3351-3-0166,QTY :1

Source: SDR CALA2023102003126
WARNING INDICATION; OTHER · 2023-10-11 Matched by certificate designator
ATA 2200

Part: COMPUTER — FAULTY (STA 328) · airframe 78,422 hrs · 15,315 cycles

AUTOTHROT DISC ON TAKE OFF AFTER SELECTING A/T A/T DISC EICAS. T/S AS PER FIM 22-32 FAULT TREE 803. REMOVED AND REPLACED THRUST :1 MANAGEMENT COMPUTER AS PER AMM 22-31-01-404-005, PERFORMED MCDP ROTABLE PARTS CHANGE WAS INDICATED - TT # 1615633 SN OFF 0085 TESTS 02 AND 30. ALL TESTS PASSED, A/C REMAINS FULL CAT CAPABILITY. OK TO CONTINUE. PARTS USED: 76-2231-9-0001,QTY COMPUTER, THRUS OFF 76-2231-9-0001 0085 ON 76-2231-9-0001 2232

Source: SDR CALA2023101303042
WARNING INDICATION; OTHER · 2023-10-11 Matched by certificate designator
ATA 2230

Part: SERVO — FAULTY (AUTOTHROTTLE) · airframe 78,422 hrs · 15,315 cycles

RTO AT 10KTS DUE TO AUTOTHROT DISC EICAS TOMC LOCKS LOG FOR REPEAT WRITEUP AND SECOND RTO IN 2 DAYS UNLOCK TO CLEAR PERFORMED MCDP TESTS 02, 10, 30, 52, & 60. ALL TESTS PASSED EXCEPT TEST 10, SHOWED TLA L FAIL-FWD AND TLA R FAIL-FWD. NEEDS FURTHER T/S. SERVO, AUTOTHRO OFF 75-2232-9-0001 0351 ON 64-2232-9-0001 1229 SERVO, AUTOTHRO OFF 75-2232-9-0001 0351 ON 0000 REMOVED AND REPLACED SERVOMOTOR GENERATOR PER AMM 22-32-01. PERFORMED MCDP TEST 10 SERVO A/T AND MCDP TEST 30 PER AMM 22-00-02. NO FAULTS. SYSTEM CHECKS OK. AIRCRAFT FULL CAT CAPABLE.

Source: SDR CALA2023101303040
FLT CONT AFFECTED; WARNING INDICATION · 2023-09-24 Matched by certificate designator
ATA 2700

Part: PROXIMITY SWITCH — DAMAGED (STA 328) · airframe 78,258 hrs · 15,292 cycles

LE SLAT ASYM CAUTION UPON FLAP RETRACTION BETWEEN 1 AND UP FLAP NEEDLES BOUNCED DURING PILOT DEBRIEF THE CAPTAIN INDICATED THAT THE FLAPS/SLATS NEVER DID GET TO 0 POSITION DETENT. FSEU BITE SHOWED 1 FAULT. LE OUTBD ASYM WITH MESSAGE 27-80121 MESSAGE WAS ACTUALLY 27-81021. ACP RESISTANCE AND INDUCTANCE MEASUREMENTS ON RT HAND OB LE SLATS REF AMM 27-88-99-206-001. NO SIGNIFICANT FINDINGS. ACP VISUAL CHECK OF UNIT, ASSY, PRO OFF 76-3260-9-0005 0977 ON 76-3260-9-0005 9028 UNIT, ASSY, SENSORS & CHECKED GAP MEASUREMENTS REF AMM 27-88-01. NO FINDINGS. ACCOMPLISHED LE AND TE FLAP OP'S CHECK PER AMM 27-81-00/27-51-00. FLAP OPERATION AND INDICATION WAS NORMAL WITH NO EICAS MSG'S OR WARNING LIGHT.

Source: SDR CALA2023092702890
FLUID LOSS · 2023-06-14 Matched by certificate designator
ATA 7300

Part: SEAL — LEAKING (RT ENG) · airframe 77,106 hrs · 15,140 cycles

RIGHT ENGINE FUEL LEAK FOUND AT FMU TO FUEL PUMP JOINT FACE. REPLACED FUEL TRANSFER TUBE SEALS BETWEEN PUMP AND FMU WITH REF TO AMM 73-21-01/401. ACCOMPLISHED ENGINE IDLE RUN AND NO LEAKS FOUND. ALL OK.

Source: SDR CALA2023061601890
FLUID LOSS; WARNING INDICATION · 2023-05-28 Matched by certificate designator
ATA 2840

Part: PROCESSOR — INOPERATIVE · airframe 76,919 hrs · 15,114 cycles

AT FL330 THE CENTER AND TOTAL FUEL QUANTITY BLANKED OUT. REQUESTING MEL COMPLIED WITH MEL DISPATCH DESK: 35 NAME: DATE: 28-MAY-23- NOC DESK: 767 NAME: DATE: 28-MAY-23- CENTER FUEL QTY IND INOP PER CREW DEBRIEF, CENTER TANK FUEL GUAGE BLANKING REST OF LEG -00 FAULTS ADDED INTERMITTANTLY. PERFORMED BITE CHECK ON FQIS REF FIM 28-41 FAULT TREE 847. FOUND FAULT HISTORY FROM LEG -00, SEE ATTACHED PICTURES. C/W FIM 28-41 FAULT TREE 859. ALL SYSTEM INDICATIONS NORMAL. C/W REF AMM 28-41-08. PARTS USED: 75-2842-9-0010,QTY :1 FIM 28-41 FAULT TREE 847, PERFORMED FQIS BITE. NO PRESENT LEG ROTABLE PARTS CHANGE WAS INDICATED - TT # 1079016 SN OFF 0500 FAULTS, SELF TEST PASSED. PER FIM 28-41 FAULT TREE 851 SHEET 1, NO FURTHER ACTION REQUIRED. AS PRECAUTIONARY, R&R FQIS PROCESSOR INFO ONLY, ADDITIONAL PERSONNEL, ALSO ADD U348946 ADD EMP:U187639,U181326,U354353 PROCESSOR, FUEL OFF 75-2842-9-0010 0500 ON 75-2842-9-0010 0468

Source: SDR CALA2023053101717

2022

OTHER · 2022-12-26 Matched by certificate designator
ATA 5753

Part: DOOR — MISSING (RT WING TE FLAP) · airframe 75,223 hrs · 14,885 cycles

PDA 3, RH INBOARD FLAP SLOT DOOR FOUND MISSING. APPROVED PANEL PREVIOUSLY INSTALLED! REQUIRES DISASSEMBLING OF THE TUBE DRIVE. DOOR REQUIRES DRILLING HOLES AND INSTALLING HARDWARES TO ATTACH THE HING ASSEMBLY. 2 RIVETS P/N BACR15BB6AD, 4 BOLTS BACB30NN3K5, 4 NUTS MS21042L3, 4 WASHERS P/N AN960JD10L. NOT ENOUGH GROUND TIME TO ACCOMPLISH TASK. UPDATED MATERIALS AND LABOR. IPC 27-51-03-21. DOOR, ASSY NOT IN STOCK AT EWR UNABLE TO WORK ITEM. INSTALLED PIVOT ARM AND FWD DOOR. REF SRM 52-40-02

Source: SDR CALA2022122603501
NO TEST · 2022-12-14 Matched by certificate designator
ATA 2561

Part: RELAY — DEFECTIVE (M1136 MODULE) · airframe 75,095 hrs · 14,868 cycles

REF AAR N/R 9668954. P61 SQUIB TEST #2, RIGHT SPOILER DO NOT TEST REMOVED AND REPLACED RIGHT OFF WING ESCAPE M1136 MODULE RELAYS K4 AND K6 AND PERFORMED P61 PANEL #2 RIGHT SPOILER SQUIB TEST FOUND NORMAL. PER B767 FIM 25-65 TASK 820, WD 25-65-11 AND AMM 26-21-04. WORK ACCOMPLISHED BY V891303

Source: SDR CALA2022121603393
OTHER · 2022-03-19 Matched by certificate designator
ATA 5300

Part: STIFFENER — NONE (RH) · airframe 72,463 hrs · 14,513 cycles

EA 5310-07143 OP 004 - B767-FABRICATE/INSTALL STIFFENER REPAIR PARTS RIGHT SIDE TRANSFER REF HXCR 647442 AND ORIGINATED BY EMP V897470

Source: SDR CALA2022032100716
OTHER · 2022-03-17 Matched by certificate designator
ATA 5300

Part: SKIN — CRACKED (BS1660-1670) · airframe 72,463 hrs · 14,513 cycles

SUPPORT TASK- EA5380-01178 REV.A OP.002, 1EA CRACK FOUND BETWEEN BS1660 AND 1670 STR 13AR APPROX. 3/8" IN LENGTH DETAIL REFER FINDING RECORD. TRANSFER WO.643912 AND ORIGINATED BY V906014. SRM 53-80-01-2R-7 RPR 7 TABLE 202 DETAIL XIV FUSELAGE SKIN BS 1660-1670 STR13AR SKIN REPAIRED IAW SRM 53-80-01-2R-7 RPR 7 FIG 201 DETAIL VII. REPEAT INSPECTIONS PER SRM 53-80-01-2R-7 RPR 7 , 5. INSPECTION REQUIREMENTS : TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTION THRESHOLD OF DOUBLER BETWEEN BWS1660 AND 1670 STRINGER 13AR 37,500 FLT CYCLES AFTER AIRPLANE DELIVERY OR WITHIN 7,500 FLT CYCLES FROM THE REPAIR INSTALLATION, WHICHEVER COMES LAST. REPEAT INSPECTIONS: 7,500 FLT CYCLES QC RECORDS UPDATE QC REVIEW INIT: 37,500 TAFC (LATER LIMIT) INIT (-0703) WILL ITO TO RIR (-0704) RIR: 7,500 FC...LN/U253409

Source: SDR CALA2022032100705
OTHER · 2022-01-31 Matched by certificate designator
ATA 2131

Part: CABIN PRESSURE — UNKNOWN (NA) · airframe 72,171 hrs · 14,475 cycles

CABIN DPRESSURIZED ON DESCENT AND DPI SHOWED 0 AT 3000 FT. LOUD AIR SOUND AT 2L REPORTED FIM 21-31 TREE 803, NO FAULTS REPORTED. CYCLED OUTFLOW VALVE, NO DEFECTS WITH VALVE NOTED. ACP''D GENERAL VISUAL INSPECTION OF CABIN DOOR 2L, OUTER FUSALAGE AREA AROUND DOOR 2L AND OUTFLOW VALVE. ALSO LOOKED AT AFT PRESSURE BULKHEAD, NO DEFECTS NOTED IN ANY AREAS. ACP''D BITE AND VERIFY OF BOTH LEFT AND RIGHT CABIN PRESSURE CONTROLLERS REF ADD EMP:348842 REF AMM 05-51-24 PERFORMED EXCESSIVE LEAKAGE TEST USING APU,ALL PARAMETERS NORMAL. REPEATED TEST USING ENGINES, ALL PARAMETERS NORMAL. NO LEAKS NOTED AT DOOR 2L. ADD EMP:121056

Source: SDR CALA2022013100272

2021

OTHER · 2021-10-01 Matched by certificate designator
ATA 2200

Part: NONE — NONE (AUTO THROTTLE) · airframe 71,058 hrs · 14,317 cycles

DURING INTIAL CLB AUTO THROTTLE DISARMED ON IT S OWN. AFTER RE-E NGING A/C ACCELERATED TO UNCOMMANDED SPEED. (CONTINUED LANGUAGE FROM LP 7143700) REF LP 7146211 FOR CORRECTIVE ACTION. ENG IDG WAS RUN AND PROVIDED CLEAN PWR. ACP''D A/T MCDP TEST 2 TMC REF 22-00-02. AN EMPLOYEE FILE #106649

Source: SDR CALA2021100101759
OTHER · 2021-10-01 Matched by certificate designator
ATA 2450

Part: BATTERY PACK — NONE (EMERGENCY LIGHT) · airframe 71,058 hrs · 14,317 cycles

PER FA, CABIN EMERGENCY LIGHTS STARTED FLICKERING AT 10K''. REF LP 7146211 FOR CORRECTIVE ACTION. ENG IDG WAS RUN AND PROVIDED CLEAN PWR. LP 7146211 DETAILS - TS FOUND NUETUAL CABLE FOR FEEDER CABLE W208-004-4 AT GD5248-ACNOT SECURED, SECURE 2EA GROUND BOLT PROPERLY TO GROUND STUD. IDLE RUN BOTH ENGINES FOR APPROX 10 EVERYTHING OPS NORMAL NO FLICKERS OF LIGHTS , VOLTAGE AC AND DC FREQ NORMAL. REF AMM 24-11-01-004-002-006 AND WDM 24-21-21 106649

Source: SDR CALA2021100101750
OTHER · 2021-07-26 Matched by certificate designator
ATA 3350

Part: LIGHT — DAMAGED (FWD GALLEY) · airframe 70,322 hrs · 14,202 cycles

FWD GALLEY FLOOR PROXIMITY EMERGENCY LIGHT FOUND DAMAGED. R&R FWD GALLEY FLOOR PROXIMITY EMERGENCY PATH LIGHT IAW AMM 33-51-10. GND CHECKS GOODS.

Source: SDR CALA2021072601197

2020

WARNING INDICATION · 2020-12-09 Matched by certificate designator
ATA 2751

Part: TRANSMITTER — FAILED (TE FLAPS) · airframe 68,774 hrs · 13,920 cycles

AFTER T/O WHEN WE WENT FROM FLAPS 5 TO 1 WE GOT TRAILING EDGE FLAP DISAGEE AND FLAP STAYED AT FLAP 5 ABOVE INF IS ACCURATE, PER CREW DEBRIEF. AT ARRIVAL, BITE CHECKED FSEU AND FLT LEG 0 SHOWS C FLAP/STAB POS WITH CORRELATED FAULT MESSAGE 27-51101, FDE "TE DISAGREE" INTERMITTENT. NEED TO RESEARCH AND TS AS NECESSARY. CHECK AS NECESSARY FOR TS, PER FIM 27-51-00-815-809 PG 10 TABLE A, NEED TO ACCOMP FSPM BITE. FOUND NO CURRENT FDE OR FAULTS. PERFORMED BITE ON FSEU CONFERMED MESSAGE 27-51101 ON LEG 0. RAN FLAP/SLATS UP AND DOWN SEVERAL TIMES, AMBER CAUTION "TE FLAP DISAGREE" BETWEEN DETENTS 5-15. FLAPS NEVER STOPPED AND MESSAGE WAS ONLY MOMENTARY. PERFORMED BITE CHECK ON FSEU FAULT MESSAGE 27-51104. PERFORMED FSPM, REF FIM 27-58-00-01 FIG 104, NO FAULTS. NEED MORE T/S 839 C FLAP/STAB POSITION P50) ACP''D FIM 27-51-00-815-838 WITH EICAS "TE FLAP SHUTDOWN" SHOWN. EICAS AND RELAY K350, OPERATIONS NORMAL. ORDERED M476 FLAP POS XMTR 4 M ADJUSTMENT AND TEST, PER AMM27-51-45-822-161 REPLACED NR 4 FLAP POSITION XMITER, PER AMM27-51-45. NEED TO ACP ROTABLE PARTS CHANGE WAS INDICATED-TT NR 1070931 S/N OFF 1774 IPC REFERENCE NR 27-51-45-05 TRANSMITTER, FL OFF 76-2754-9-0002 1774 ON 76-2754-9-0002 0236 ACP ADJUSRMENT OF FLAP POSITION NR 4, PER AMM 27-51-45-822-161. FSEU BITE CHECKS GOOD. OPERATION OF FLAPS NORMAL WITH NO EICAS MESSAGES OR FLAP SHUTDOWN. POSITION INDICATION CHECKS OK. SYSTEM CHECKS OK.

Source: SDR CALA2020120901354

2019

FLAME/FIRE; SMOKE/FUMES/ODORS/SPARKS · 2019-11-01 Matched by certificate designator
ATA 2530

Part: OVEN — FIRE (GALLEY) · airframe 67,262 hrs · 13,702 cycles

OVEN 107 CAUGHT FIRE AND ARCHED. CREW DEBRIEFED AS PER AMM 05-51-56-940-801C1, SOURCE VERIFIED TO BE OVEN 107 IN FORWARD GALLEY. OVEN INTERNAL REAR ELEMENT AND F AN COVER REMOVED AND NOTED TO BE HEAVILY CONTAMINATED WITH BURNT FOOD REMAINS. SMOKE/ODUR IN THE CABIN FORMS 46-6020 COMPLETED B Y BOTH CABIN AND FLIGHT CREW PER AMM 05-51-56. ALL 5 FORWARD E REPLACED. REMAINING OVENS REFITTED INTO ORIGINAL POSITIONS. ELECTRICAL FIRE. OVEN 107 LEFT REMOVED REF LOGPAGE 3716713 TO B ND, CIRCUIT BREAKER HAD NOT TRIPPED AND THERE WAS NO EVIDENCE OF EHIND INSPECTED FOR ANY SIGNS OF OVERHEATING OR DAMAGE, NONE FOU GALLEY OVENS REMOVED AS PER AMM 25-34-00 CONNECTORS AND WIRING B ESFR RAISED AS PER GMM 04-20-16.

Source: SDR CALA2019110501918
OTHER · 2019-04-16 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 325) · airframe 65,351 hrs · 13,427 cycles

STA LBL54 FLOOR SUPPORT FOUND CORRODED, CABIN STA 325 FLOOR BEAM BETWEEN LBL44 AND LBL58 REPAIRED PER SRM 53-00-51 REPAIR 4 FIG 201. HFES INSP CARRIED OUT PER NTM PART 6 51-00-19, NO CRACK FOUND AT TRIMMED EDGE.

Source: SDR CALA2019041900601

2018

NO WARNING INDICATION · 2018-11-09 Matched by certificate designator
ATA 2841

Part: PROCESSOR — FAILED (FUEL QTY INDICAT) · airframe 64,271 hrs · 13,269 cycles

CENTER FUEL QUANTITY INDICATOR WENT BLANK REPLACED PROCESSOR AS PER AMM 28-41-08-004-001, OPS CHECK NORMAL. NO MESSAGES OR FAULTS AT THIS TIME. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1417568 SN OFF 0480 IPC REFERENCE # IPC 28-41-08

Source: SDR CALA2018110902326
FALSE WARNING · 2018-02-09 Matched by certificate designator
ATA 3416

Part: ALTIMETER — READS HIGH (STANDBY) · airframe 60,894 hrs · 12,827 cycles

STANDBY ALTIMETER READS PLUS 600 FEET AT ALTITUDE. REMOVED AND REPLACED THE STANDBY ALTIMETER IAW AMM 34-13-06-344-031. OPS CHECKED SATISFACTORY. NO DEFECTS NOTED. OK TO CONTINUE.

Source: SDR CALA2018020900536
OTHER · 2018-02-09 Matched by certificate designator
ATA 2560

Part: SWITCH — MISSING (EVACUATION) · airframe 60,894 hrs · 12,827 cycles

FA JUMPSEAT, MISSING THE EVACUATION SWITCH. R & R THE EVACUATION CONTROL PANEL IAW AMM 25-63-00, TESTED GOOD.

Source: SDR CALA2018020900549
OTHER · 2018-02-09 Matched by certificate designator
ATA 2565

Part: CLEVIS — DAMAGED (RT OVRWG SLIDE) · airframe 60,894 hrs · 12,827 cycles

RIGHT OVERWING ESCAPE SLIDE COMPARTMENT DOOR, FWD LATCH CONTROL ROD, FWD CLEVIS IS BENT AND RUSTED. REPLACED THE CLEVIS.

Source: SDR CALA2018020900548

2017

OTHER · 2017-12-08 Matched by certificate designator
ATA 3350

Part: SIGN — UNKNOWN (CABIN) · airframe 60,190 hrs · 12,726 cycles

FLIGHT DECK EXIT SIGN DOES NOT WORK WHEN OVERHEAD PANEL 5 EMERGENCY EXIT SWITCHED TO ON. REF CARD76-2333-1-6190. LIGHTS OPS CHK NORMAL.

Source: SDR CALA2017120804351
OTHER · 2017-12-08 Matched by certificate designator
ATA 3350

Part: LIGHT — UNKNOWN (CABIN) · airframe 60,190 hrs · 12,726 cycles

FLOOR MOUNTED EMERGENCY ESCAPE LIGHTING AND 4 SMALL EXIT LIGHTS AT OVERWING EMERGENCY EXITS ARE INOP. LIGHTS OPS CHK NORMAL.

Source: SDR CALA2017120804352
OTHER · 2017-12-08 Matched by certificate designator
ATA 3397

Part: PIN — DAMAGED (CONNECTOR) · airframe 60,190 hrs · 12,726 cycles

EMERGENCY EXIT LIGHTS ON SEAT 24 DEF BOTH SIDES ARE INOP. REMOVED AND REPLACED DAMAGED PIN ON CONNECTOR TESTED EMERGENCY LIGHTS ON SEAT 24 DEF OPS CK GOOD REF SWPM 20-00-12 AND AMM 33-51 -00.

Source: SDR CALA2017120804353
NO TEST · 2017-08-25 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 58,902 hrs · 12,543 cycles

EMERGENCY LIGHT FWD OF AFT CARGO DOOR DOES NOT OPERATE DURING EMERGENCY LIGHT TEST. REPLACED THE LAMPS. OPS CHECKED GOOD.

Source: SDR CALA2017082502882
NO TEST · 2017-08-25 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 58,902 hrs · 12,543 cycles

EMERGENCY LIGHT JUST AFT OF THE L1 DOOR IS NOT OPERATING DURING EMERGENCY LIGHT TEST. REPLACED THE LAMPS, OPS CHECKED GOOD.

Source: SDR CALA2017082502881
OTHER · 2017-07-17 Matched by certificate designator
ATA 3350

Part: SIGN — LOOSE (CABIN) · airframe 58,462 hrs · 12,483 cycles

EMERGENCY EXIT SIGN INOP AT FIRST ROW OF COACH. SECURED EXIT SIGN, OK FOR SERVICE.

Source: SDR CALA2017071702267
OTHER · 2017-06-01 Matched by certificate designator
ATA 7297

Part: WIRE HARNESS — CHAFED (NR 1 ENGINE) · airframe 57,934 hrs · 12,406 cycles

LEFT ENGINE WIRE BUNDLE CHAFED AT PNEUMATIC LINE AFT & INBD OF FWD MOUNT. REMOVED & REPLACED WIRES W002-725/726-YR, & W002-727/725-YR IAW WDN 71-51-14 PG 1.B, BSWPM 20-10- 11, BSWPM 20-63-19 & RAN THE NR 1 ENGINE IAW JRH & AMM 71-00-00, TESTED GOOD.

Source: SDR CALA2017060201653
OTHER · 2017-05-27 Matched by certificate designator
ATA 5311

Part: FRAME — DAMAGED (BS 883.5) · airframe 57,934 hrs · 12,406 cycles

(AD 5310-05292-9) DURING ACCOMPLISHMENT OF AD RELATED CARD FOR LH FRAME INNER CHORD REPAIR AT STA 883.5 FRAME WAS DAMAGED AT AREA OF REPAIR. REPAIRED LT INNER FRAME CHORD AT MAIN CABIN BS 883.5 IAW UNITED ECRA 5310-07141

Source: SDR CALA2017052701620
NO TEST · 2017-05-27 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DEFECTIVE (EMERGENCY LIGHTS) · airframe 57,934 hrs · 12,406 cycles

NUMEROUS EMERGENCY LIGHTS NOT STAYING ILLUMINATED MORE THAN 20 SECOND WHEN SWITCHED ON. TROUBLESHOT THE EMERGENCY LIGHTS AND REPAIR THE TIMING DELAY IAW AMM 33-51-02. OPS CHECKED GOOD IAW 33-51-02, 20 SECOND TIME DELAY OPS CHECKED GOOD IAW AMM 25-22-01, AND REMOVED AND REPLACED THE BATTERY PACK, OPS CHECKED GOOD AMM 33-51 -07.

Source: SDR CALA2017052701611
OTHER · 2017-05-27 Matched by certificate designator
ATA 5230

Part: STRAP — GOUGED (AFT CARGO DOOR) · airframe 57,934 hrs · 12,406 cycles

DISCOVERED TWO GOUGES ON THE LOWER END ATTACH STRAP, REPAIRED IAW SRM 53-30-01, RPR 6, PAGES 201-5.

Source: SDR CALA2017052701622
OTHER · 2017-05-27 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1570) · airframe 57,934 hrs · 12,406 cycles

AFT WASTE SERVICE PAN ATTACH DOUBLER BS 1570, BL 0 IS CORRODED. REMOVED, FABRICATED, AND INSTALLED AFT WASTE SERVICE PAN ATTACH DOUBLER IAW DWG 146T3250 AND SRM 51-40-02, PAR 7D, FIG 12.

Source: SDR CALA2017052701619
OTHER · 2017-05-25 Matched by certificate designator
ATA 5322

Part: SHEAR TIE — CORRODED (BS 1540) · airframe 57,934 hrs · 12,406 cycles

AFT CARGO BAY BS 1540 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 38R AND 39R, OUT OF SRM LIMITS. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02, PAR 4.

Source: SDR CALA2017052601565
OTHER · 2017-05-25 Matched by certificate designator
ATA 5322

Part: SHEAR TIE — CORRODED (BS 1540) · airframe 57,934 hrs · 12,406 cycles

AFT CARGO BAY, BS 1540 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 38L & 39L, FOUND TO BE OUT OF LIMITS. REMOVED, FABRICATED, LOCATED, DRILLED AND INSTALLED A NEW SHEAR TIE IAW SRM 51-40-02, PAR 4, & ENGINEERING DOCUMENT 140T2102, TYPE PL, REV FR.

Source: SDR CALA2017052601567
OTHER · 2017-05-25 Matched by certificate designator
ATA 5322

Part: SHEAR TIE — CORRODED (BS 1562) · airframe 57,934 hrs · 12,406 cycles

AFT CARGO BAY, BS 1562 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 39 L AND 39R. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02, PARA 4 AND 7.

Source: SDR CALA2017052601566
OTHER · 2017-05-23 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 1400) · airframe 57,934 hrs · 12,406 cycles

CORROSION ON STRINGER 39R AT BS 1400. REMOVED DAMAGED SECTION OF STRINGER AND REPLACED WITH REPAIR IAW SRM 53-00-03, FIG 201, REPAIR 2.

Source: SDR CALA2017052601559

2016

OTHER · 2016-11-21 Matched by certificate designator
ATA 3350

Part: LIGHT — INTERMITTENT (CABIN) · airframe 56,235 hrs · 12,171 cycles

EMERGENCY LIGHTS TURNED ON AND OFF FOR 3 SECONDS BY THEMSELVES. PERFORMED OPERATIONAL TEST EMERGENCY LIGHT IAW AMM 33-51-00-715- 001-001. OK FOR SERVICE.

Source: SDR CALA2016112100950
PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2016-10-07 Matched by certificate designator
ATA 7230

Part: COMPRESSOR — DAMAGED (NR 1 ENGINE) · airframe 55,775 hrs · 12,110 cycles

LOW SPEED ABORT DURING TAKEOFF (80 KTS) DUE TO LOUD NOISE ON NR 1 ENGINE. NO VISIBLE EXTERNAL DAMAGE TO FUSELAGE. ALL TIRES, WHEELS AND BRAKES OK. SURGE MESSAGE ON EICAS. COMPRESSOR DAMAGE FOUND, ENGINE REPLACEMENT

Source: SDR CALA2016100700730
FALSE WARNING · 2016-06-27 Matched by certificate designator
ATA 2781

Part: SENSOR — DEFECTIVE (LE SLAT) · airframe 54,634 hrs · 11,943 cycles

EICAS MSG L/E SLAT ASYM DISPLAYED, L/E LIGHT ILLUMINATED WITH THE FLAP LEVER IN 1. BOTH FLAP POINTERS ARE CORRECT. T/S IAW FIM TASK 27-81/809. FOUND S302, SLAT 10 INBD TO BE FAULTING. CONFIRMED S302 TO BE BAD IAW L/E SLAT SYSTEM HEALTH CHECK IAW AMM 27-88-99. R & R S302 IAW AMM 27-88- 01. PERFORMED ADJ/ TEST IAW AMM 27-88-00. ALL CHECKS GOOD, NO FAULTS NOTED.

Source: SDR CALA2016062700389

2015

WARNING INDICATION · 2015-09-21 Matched by certificate designator
ATA 3442

Part: TRANSCEIVER — FAILED (WEATHER RADAR) · airframe 51,585 hrs · 11,508 cycles

INITIALLY, WXR RADAR TILT & INDICATIONS ERRONEOUS WITHOUT FAIL MSG. RESET CB IAW QRH, SYS RECOVERED, WORKED NORMALLY 3 HRS & THEN FAILED WITH WX FAIL MSG DISPLAYED. DIVERTED DUE TO WEATHER & EMER DECLARED. REPLACED WEATHER RADAR TRANSCEIVER IAW AMM 34-43-01-401. SYS OPERATIONS CHECKED GOOD.

Source: SDR CALA2015092494395
OTHER · 2015-09-04 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CORRODED (RT MLG WW) · corrosion level 2 · airframe 51,401 hrs · 11,478 cycles

C53-144-01 CORROSION IN RT WW FWD BULKHEAD, STATION 955, INBD SIDE OF REAR SPAR FITTING, 4" BELOW BOTTOM EDGE OF CANTED PRESS DECK BS 955. REPAIRED CORRODED AREA IAW ECRA 5340-01 668.

Source: SDR CALA2015090894273
OTHER · 2015-08-07 Matched by certificate designator
ATA 5310

Part: DOOR FRAME — CRACKED (FUSELAGE) · airframe 51,401 hrs · 11,478 cycles

2.5" CRACK AT STATION 610, RBL42 FWD CARGO FLOOR STRUCTURE FRAME, LOWER DOOR STRUCTURE. R & R PN 143T8236-7 CORD IAW DWG 143T1208 SH1 & SRM 51-40-02. NO FURTHER ACTION REQUIRED.

Source: SDR CALA2015081194188
FLUID LOSS · 2015-07-18 Matched by certificate designator
ATA 2910

Part: O-RING — DAMAGED (HYDRAULIC SYS) · airframe 51,319 hrs · 11,466 cycles

AIRCRAFT LOSING LT HYD QTY, QRH FOLLOWED, PUMPS OFF & HYD QTY STOPPED DECREASING. ACCOMPLISHED AMM FAULT TREE 29-11-815 & FOUND DPI INDICATOR LEAKING FROM O RING ON EDP PRESS MODULE. REPLACED O RINGS IAW MM 29-11-17. PRESSURIZED & CHECKED FOR LEAKS, NONE. QTY HAD DROPPED TO .48. SERVICED HYD SYS.

Source: SDR CALA2015072194139
SMOKE/FUMES/ODORS/SPARKS · 2015-07-02 Matched by certificate designator
ATA 2330

Part: MODULE — MALFUNCTIONED (CABIN) · airframe 51,107 hrs · 11,433 cycles

SEAT 1A IFE CONTROL BOX REPORTED OVERHEATED. FOUND HOT AREA AROUND SEAT 1A IFE BOX. CONNECTORS REMOVED, CAPPED & STOWED, OTHER ADJACENT COMPONENTS CONNECTORS REMOVED, CHECKED & REFITTED. NO FURTHER SMELLS EVIDENT DURING OR POST DEACTIVATION. R & R SEAT POWER MODULE IAW AMM 23-81-08.

Source: SDR CALA2015070694050
SMOKE/FUMES/ODORS/SPARKS · 2015-07-02 Matched by certificate designator
ATA 2330

Part: MODULE — DEFECTIVE (CABIN) · airframe 51,107 hrs · 11,433 cycles

CREW REPORTED VERY HOT AIR FROM VENT AT SEAT 1A IN 1ST CLASS. 2ND CALL CREW REPORTED BURNING SMELL. DIVERSION, CHECKED THE AREA WITH A THERMAL IMAGING CAMERA, SEAT BOTTOM WAS REMOVED & THE EXPOSED IFE CONTROL BOX WAS IDENTIFIED AS HOT AT 47C WHICH WAS NOTICEABLY WARMER WITH A FAINT ODOR. NO OTHER HOT SPOTS IDENTIFIED. REPLACED SEAT POWER MODULE IAW AMM 23-81-08. OPERATIONS CHECKED NORMAL.

Source: SDR CALA2015070294038

2014

SMOKE/FUMES/ODORS/SPARKS · 2014-09-13 Matched by certificate designator
ATA 2530

Part: CHILLER — INOPERATIVE (GALLEY) · airframe 47,970 hrs · 11,007 cycles

AFT GALLEY SMOKE ODOR, CHILLER INOPERATIVE. R & R AFT RT GALLEY CHILLER IAW AMM 25-33-02. 28VDC PIN 6 NO 115VAC PINS 1, 2 & 3 AT CHILLER WDM 25-33-11, NO 115VAC AT RT AFT GALLEY POWER PANEL. SUSPECT RT AFT GALLEY ELCU TRIPPED. CYCLED RT UTILITY BUS SWITCH. POWER NOW AVAIL AT AFT RT GALLEY POWER PANEL. OPERATED ALL ASSOCIATED EQUIP WITH PANEL WITHOUT ODOR OR DEFECTS FOR 10 MINUTES.

Source: SDR CALA2014091892230
WARNING INDICATION · 2014-05-24 Matched by certificate designator
ATA 3610

Part: SHUTOFF VALVE — FAULTY (BLEED AIR SYS) · airframe 46,518 hrs · 10,825 cycles

DURING CLIMB RT ENG HPSOV EICAS WITH LIGHT. REPLACED NR 2 ENG HPSOV & CONTROLLER IAW AMM 36-11-08 & 36-11-07. OPERATIONS CHECKED GOOD.

Source: SDR CALA2014060991251
SMOKE/FUMES/ODORS/SPARKS · 2014-02-25 Matched by certificate designator
ATA 2120

Part: UNKNOWN — SMOKE (CABIN) · airframe 45,558 hrs · 10,712 cycles

SMOKE IN THE CABIN, SMOKE OCCURRED AT DEPARTURE. CUSTOMERS WERE DEPLANED.

Source: SDR CALA2014022790496
OTHER · 2014-02-03 Matched by certificate designator
ATA 7110

Part: FIRESEAL — DAMAGED (NR 2 ENGINE) · airframe 45,298 hrs · 10,681 cycles

E2 OTBD THRUST REVERSER UPPER FWD FIRE SEAL DAMAGED. REPLACED E2 OTBD UPPER FWD FIRE SEAL IAW CMM 71-11-56, ALL CHECKED NORMAL.

Source: SDR CALA2014020690316

2013

OTHER · 2013-12-30 Matched by certificate designator
ATA 7230

Part: FAIRING — DAMAGED (NR 2 ENGINE) · airframe 44,966 hrs · 10,630 cycles

NR 2 ENG COMPRESSOR INTERMEDIATE CASE FAIRING AT 3 O'CLOCK POS HAS HOLE IN FAIRING. R & R 2 ENG COMPRESSOR CASE FAIRING IAW AMM. NO FURTHER DEFECTS NOTED AT THIS TIME.

Source: SDR CALA2014010290042
PARTIAL RPM/PWR LOSS · 2013-12-26 Matched by certificate designator
ATA 7321

Part: EEC — FAULTY (RT ENGINE) · airframe 44,934 hrs · 10,625 cycles

RT ENGINE EGT DROPPED TO ZERO APPROXIMATELY 12 MIN INTO FLT. EGT RETURNED TO NORMAL WITHIN 5 SEC. CONT NXT MR SAMC TEXT STBY EGT ALSO ZERO. ENG OPERATIONS NORMAL, EGT NORMAL FOR DURATION OF FLT. NEED TO CHECK ALL CONNECTIONS FOR SECURITY ESPECIALLY W6 CONNECTIONS. ACCOMPLISHED MM 71 PIMU CHECK FOR MESSAGES. ALSO CHECK STUDS & LUG CONNECTIONS IN J BOX & AT EGT PROBES. CHECK HARNESSES A ROUND EXH CASE TO J BOX & W6 HARNESS FWD OF J BOX. TROUBLE SHOT IAW FIM SUSPECT EEC. R & R IAW AMM 73-21-04-401, CHECKED GOOD. PIMU CHECKED GOOD.

Source: SDR CALA2013122793974
OTHER · 2013-12-20 Matched by certificate designator
ATA 2161

Part: CONTROLLER — INOPERATIVE (COCKPIT TEMP) · airframe 44,868 hrs · 10,615 cycles

FLT DECK TEMP VERY HARD TO CONTROL, HAD TO USE MANUAL, PER CREW. FLT DECK TEMP CTRL INOPERATIVE, USE MANUAL, DEFERRED IAW MEL.

Source: SDR CALA2013122093845
FLUID LOSS · 2013-12-12 Matched by certificate designator
ATA 2910

Part: HYDRAULIC LINE — LEAKING (THRUST REVERSER) · airframe 44,850 hrs · 10,611 cycles

HYD LEAK FOUND AFT OF NR 2 ENG DRIPPING FROM PYLON. FOUND FROM THRUST REVERSER ISOLATION VLV ASSEMBLY ONE LINE LEAKING IAW 272T0242-100, IPC 78-34-07-01, FIGURE 3 ITEM 100. PERFORMED INTERIM REPAIR WITH AA FLEXIBLE LINE BACH8A08NN0161. RT ENG THRUST REVERSER OPERATIONS CHECKED OK & LEAK CHECKED OK IAW AMM 78-34-07.

Source: SDR CALA2013121393677
OTHER · 2013-12-11 Matched by certificate designator
ATA 2820

Part: ACTUATOR — FAULTY (FUEL SYSTEM) · airframe 44,839 hrs · 10,610 cycles

DURING OPERATION CHECKS OF LT DEFUEL VLV FOUND ACTUATOR NOT RUNNING SMOOTH. REMOVED ACTUATOR & VLV SEEMS TO BE OPERATING SMOOTHLY. TEMPORARY INSTALL ACTUATOR & OPERATION CHECKED AGAIN, ACTUATOR RUNNING SMOOTHLY. CANNON PLUG NOT FULLY SECURED BOLTS TEMPORARILY INSTALLED, IAW LOG 5. REPLACED LT DEFUEL ACTUATOR, OPERATIONS CHECKED GOOD. NO UNWANTED FUEL TRANSFERRED.

Source: SDR CALA2013121293631
OTHER · 2013-12-03 Matched by certificate designator
ATA 2421

Part: IDG — CONTAMINATED (LT ENGINE) · airframe 44,758 hrs · 10,600 cycles

IAW CALLOUT LM7758, FOUND LT IDG OIL CONTAMINATED WITH HYD FLUID. REMOVED IDG, FLUSHED SYS IAW. INSTALLED & TESTED NEW IDG IAW 24-11-0. NO OTHER DEFECTS NOTED.

Source: SDR CALA2013120393424
OTHER · 2013-12-03 Matched by certificate designator
ATA 5610

Part: SEALANT — MISSING (COCKPIT WINDOW) · airframe 44,758 hrs · 10,600 cycles

AT 350 AFTER 2HRS GOT A LOUD SQUEAL FOLLOWED BY A CHOO CHOO SOUND. CABIN ALT 5200 DIFF 8.3 CONTINUED UNTIL CABIN ALT 4000, DIFF 7.3 & NOISE STOP AT 3500, 6.8. NOISE WAS INVERT DIVIDER IN CAPTAIN'S WINDOW. NR 2 CAPTAIN`S OPEN ABLE WINDOW SEAL INSPECTED IAW MM 56-11-02, MISSING SEALANT AT THE LOWER LATCH STUD. ACCOMPLISHED INTERIM REPAIR IAW AMM 56-11-11 PB 401 PARA 1 F. OPERATIONS CHECKED OF WINDOW PERFORMED OK FOR CONT OPERATIONS. USED ALUMINUM TAPE IAW ECRA 5611-01164. INSPECTED INTERIM REPAIR, NO FAULTS FOUND. ACCOMPLISHED PERMANENT REPAIR FOR L2 COCKPIT WINDOW.

Source: SDR CALA2013120393425
OTHER · 2013-11-27 Matched by certificate designator
ATA 3510

Part: OXYGEN MASK — LEAKING (COCKPIT) · airframe 44,717 hrs · 10,594 cycles

CAPTAIN`S O2 MASK DEFECTIVE LEAKS. REPLACED MASK.

Source: SDR CALA2013120293365
OTHER · 2013-11-06 Matched by certificate designator
ATA 5310

Part: DOOR FRAME — CRACKED (FUSELAGE) · airframe 44,714 hrs · 10,592 cycles

AFT RT CARGO DOOR AFT SIDE OF DOOR CUTOUT FRAME WEB CRACKED & TORN BELOW E-6 EQUIPMENT RACK. REPAIRED IAW B767-300 SRM 53-00-07, REPAIR 3, FIG 201.

Source: SDR CALA2013110792714
WARNING INDICATION · 2013-10-06 Matched by certificate designator
ATA 3230

Part: VALVE — INTERMITTENT (TAILSKID EXTEND) · airframe 44,616 hrs · 10,577 cycles

ON GEAR EXTENSION, TAIL SKID LIGHT & EICAS ILLUMINATED. TROUBLESHOOTING FOUND MOTOR OPERATED VALVE FOR TAIL SKID INTERMITTENT. R & R VALVE ASSEMBLY, OPS CHECKED NORMAL.

Source: SDR CALA2013100991907
OTHER · 2013-09-24 Matched by certificate designator
ATA 2560

Part: COVER — UNSECURE (EXIT SIGN) · airframe 44,454 hrs · 10,556 cycles

EXIT COVER AT 1L FELL OFF. EXIT COVER AT DR 1L REFITTED. INSTALLATION & SECURITY CHECKED SATISFACTORY.

Source: SDR CALA2013092491413
FLUID LOSS · 2013-09-19 Matched by certificate designator
ATA 7520

Part: ACTUATOR — LEAKING (RT ENGINE) · airframe 44,376 hrs · 10,547 cycles

REPORTS OF FUEL LEAK FROM RT ENG DRAIN. FOUND FUEL LEAKING FROM TCC AIR VALVE ACTUATOR. R & R TCC AIR VALVE ACTUATOR IAW MM. OPERATIONS & LEAK CHECKED GOOD.

Source: SDR CALA2013092091300
FLUID LOSS · 2013-09-08 Matched by certificate designator
ATA 3830

Part: VALVE — LEAKING (LAVATORY) · airframe 44,263 hrs · 10,532 cycles

LT CENTER LAVATORY RINSE VALVE LEAKING. WATER SHUT OFF. PLACED LAVATORY ON IAW MEL 38 -30M. WATER SHUTOFF & LAVATORY SECURED. LT AFT CENTER LAVATORY PC NR 160-9511.

Source: SDR CALA2013090991141
FALSE WARNING · 2013-09-08 Matched by certificate designator
ATA 3260

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 44,257 hrs · 10,531 cycles

EICAS TAIL SKID MESSAGE & LIGHT. NO DAMAGE NOTICED ON TAIL-SKID.

Source: SDR CALA2013090991125
OTHER · 2013-08-18 Matched by certificate designator
ATA 3140

Part: COMPUTER — INOPERATIVE (LT EICAS) · airframe 44,015 hrs · 10,499 cycles

LEFT EICAS COMPUTER INOPERATIVE. R & R LT EICAS COMPUTER. SOFTWARE VERIFIED. OPS CHECKED GOOD.

Source: SDR CALA2013081990537
OTHER · 2013-08-16 Matched by certificate designator
ATA 3140

Part: MODULE — FAILED (EICAS DISPLAY) · airframe 44,000 hrs · 10,496 cycles

LOWER EICAS SCREEN LOOSES COLOR. REPLACED LOWER EICAS DISPLAY SWITCHING MODULE M10418, OPS NORMAL.

Source: SDR CALA2013081690464
OTHER · 2013-08-16 Matched by certificate designator
ATA 2350

Part: AUDIO PANEL — MALFUNCTIONED (COCKPIT) · airframe 44,000 hrs · 10,496 cycles

OBSERVER STATION VHF RADIO DOES NOT TRANSMIT AFTER CHANNEL CHANGE. REPLACED SECOND OBSERVERS AUDIO PANEL, CHECKED OK.

Source: SDR CALA2013081690473
OTHER · 2013-08-15 Matched by certificate designator
ATA 2350

Part: AUDIO PANEL — FAILED (COCKPIT) · airframe 44,000 hrs · 10,496 cycles

OBSERVER STATION 2, VHF RADIO DOES NOT TRANSMIT AFTER CHANNEL CHANGE. REPLACED 2ND OBSERVERS AUDIO PANEL, CHECKED OK.

Source: SDR CALA2013081690491
FLUID LOSS · 2013-07-19 Matched by certificate designator
ATA 2910

Part: LINE — LEAKING (HYDRAULIC SYS) · airframe 43,643 hrs · 10,453 cycles

DURING WALK AROUND FOUND HYD LEAK LT WING,TROUBLESHOT TO HYD LINE. LINE HAS TWO PIN HOLES, REQUIRES REPLACEMENT. R & R LEAKING HYD LINE IN LT WING. LEAK CHECKED GOOD.

Source: SDR CALA2013072990043
WARNING INDICATION · 2013-07-15 Unresolved
ATA 2150

Part: ACTUATOR — FAILED (RT A/C PACK) · airframe 43,617 hrs · 10,449 cycles

RIGHT PACK TEMP EICAS MESSAGE ON ARRIVAL. R & R RAM AIR ACTUATOR IAW AMM, NO DEFECTS NOTED.

Source: SDR UALA2013071604990
WARNING INDICATION · 2013-07-09 Unresolved
ATA 3140

Part: COMPUTER — FAILED (LT EICAS) · airframe 43,526 hrs · 10,439 cycles

AFTER LT ENGINE START, LT EICAS COMPUTER FAILED. R & R LT EICAS COMPUTER IAW AMM. SOFTWARE LOADED, OPS CHECKED GOOD.

Source: SDR UALA2013070904783
OTHER · 2013-07-09 Matched by certificate designator
ATA 3140

Part: COMPUTER — FAILED (LT EICAS) · airframe 43,526 hrs · 10,439 cycles

AFTER LEFT ENG START, LT EICAS COMPUTER FAILED. R & R LT EICAS COMPUTER IAW AMM. SOFTWARE LOADED, OPS CHECKED GOOD.

Source: SDR CALA20130709002
WARNING INDICATION · 2013-07-07 Matched by certificate designator
ATA 2150

Part: ACTUATOR — FAULTY (RT A/C PACK) · airframe 43,526 hrs · 10,439 cycles

RT PACK TEMP EICAS AFTER ENGINE START. SUPPLEMENTAL DATA UPDATE, R & R RT RAM AIR INLET DOOR ACTUATOR, OPS CHECKED GOOD.

Source: SDR CALA20130708002
WARNING INDICATION · 2013-07-07 Unresolved
ATA 2150

Part: ACTUATOR — FAULTY (RAM AIR DOOR) · airframe 43,526 hrs · 10,439 cycles

RIGHT PACK TEMP EICAS AFTER ENGINE START. R & R RT RAM AIR INLET DOOR ACTUATOR, OPS CHECKED GOOD.

Source: SDR UALA2013070804746
OTHER · 2013-07-03 Unresolved
ATA 3350

Part: COVER — FAULTY (EMERGENCY LIGHT) · airframe 43,475 hrs · 10,433 cycles

OVERHEAD EXIT COVER BY SEAT 15LK IS MISSING ON ONE SIDE. ECRA 3351-0167 ACCOMPLISHED INTERIM REPAIR WITH TAPE FOR MISSING EXIT SIGN BLANKING PLATE. REPLACED EXIT COVER AT ROW 15 LT SIDE.

Source: SDR UALA2013070504702
OTHER · 2013-05-20 Unresolved
ATA 2132

Part: INDICATOR — FLUCTUATES (CABIN PRESSURE) · airframe 42,910 hrs · 10,363 cycles

DPI FLUX, RTFL R & R CABIN PRESSURIZATION INDICATOR IAW AMM. OPS CHECK NORMAL, AC OK TO CONTINUE.

Source: SDR UALA2013052103509
WARNING INDICATION · 2013-05-08 Unresolved
ATA 2150

Part: ACTUATOR — FAILED (LT A/C PACK) · airframe 42,730 hrs · 10,342 cycles

LEFT A/C PACK INOPERATIVE LIGHT ON. EICAS MESSAGE LEFT A/C PACK TEMP DISPLAYED. LIGHT DID NOT EXTINGUISH WHEN STANDBY SELECTED & RESET PUSHED. REPLACED LEFT A/C PACK RAM AIR ACTUATOR.

Source: SDR UALA2013050903245
OTHER · 2013-05-08 Unresolved
ATA 3350

Part: LENS — OUT OF POSITION (CABIN) · airframe 42,741 hrs · 10,343 cycles

EXIT SIGN COVER FELL OFF RIGHT AISLE BETWEEN BUS & COACH. REPLACED LENS.

Source: SDR UALA2013050903260
FALSE WARNING · 2013-05-01 Unresolved
ATA 7330

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 42,646 hrs · 10,329 cycles

LEFT ENGINE FUEL FILTER BYPASS IND, RTFL. REF FAULT ISOLATION MAINTENANCE MANUAL 73-34-00 PG 101. RAN ENGINE PER JRH2-6-1 PER 2 MINUTES. NO LEAKS FOUND & NO FUEL FILTER BYPASS INDICATION.

Source: SDR UALA2013050203066
WARNING INDICATION · 2013-03-27 Unresolved
ATA 2565

Part: SLIDE — WARNING LIGHT (LT OVERWING) · airframe 42,240 hrs · 10,280 cycles

LEFT WING SLIDE EICAS ILLUMINATED. REPLACED LEFT OFF-WING SLIDE ASSY.

Source: SDR UALA2013032801987
FLUID LOSS · 2013-03-25 Unresolved
ATA 2910

Part: LINE — LEAKING (HYD SYSTEM) · airframe 42,228 hrs · 10,278 cycles

DURING WALK AROUND FOUND HYD LEAKAGE FROM RT WING ABOVE NR 4 MLG WHEEL. FOUND LEAKAGE FROM RT ANTI-SKID SHUTTLE VALVE MODULE LINE. RETIGHTENED LINE AND NO MORE LEAKAGE.

Source: SDR UALA2013032601926
OTHER · 2013-03-16 Unresolved
ATA 2560

Part: GIRT BAR — OBSTRUCTED (R2 DOOR) · airframe 42,081 hrs · 10,260 cycles

DOOR 2R WILL NOT ARM. YELLOW STRAP STUCK DOWN, CHECKED GOOD, NO DEFECTS, OK TO CONTINUE.

Source: SDR UALA2013031801626
SMOKE/FUMES/ODORS/SPARKS · 2013-01-28 Unresolved
ATA 2440

Part: RECEPTACLE — SPARKS (EXTERNAL POWER) · airframe 41,484 hrs · 10,181 cycles

EXTERNAL POWER RECEPTACLE HAD SPARKS WHEN EXTERNAL POWER CORD FROM JETWAY HOOKED UP. INSPECTED EXTERNAL POWER PANEL INSIDE, NO DAMAGE NOTED. NO ARCING. AIRCRAFT OK FOR SERVICE. CONFIRMED WILL NEED RECEPTACLE REPLACEMENT DUE TO ERODED PINS AND DAMAGED BASE INSULATION BETWEEN PINS "A" AND "B". WILL ALSO REQUIRE BMS 5-95 SEALANT DURING REPLACEMENT PER AMM 24-41-02.

Source: SDR UALA2013012900545
OTHER · 2013-01-24 Unresolved
ATA 5270

Part: KEY PAD — MALFUNCTIONED (COCKPIT DOOR) · airframe 41,432 hrs · 10,173 cycles

COCKPIT ENTRY CHIME INOPERATIVE WITH NORMAL CODE. REMOVED AND REPLACED COCKPIT DOOR KEYPAD AND ATTACHING HARNESS AND MODULE. DOOR CHIME FUNCTIONALLY TESTS OKAY.

Source: SDR UALA2013012500459
VIBRATION/BUFFET · 2013-01-17 Unresolved
ATA 7200

Part: ACCELEROMETER — FAULTED (NR 2 ENGINE) · airframe 41,338 hrs · 10,161 cycles

NR 2 ENGINE HIGH VIB FELT IN AIRFRAME OR THROTTLE. PERFORMED FAN LUBE AS PER 72-31-99 VIBE GOOD AT THIS TIME. ACP CK OF INLET & EXHAUST INCLUDING FAN BLADES FOR DAMAGE & MIDSPAN SHROUDS FOR SHINGLING. CHECKED VIBE PICKUP AT 1 O'CLOCK ON FAN CASE 'A' FLANGE FOR TIGHTNESS TO FLANGE & BRACKET. CHECKED CABLE FOR LOOSE OR MISSING CLAMPS. CHECKED TIGHTNESS & CONDITION OF ELECT CONNECTORS AT PICKUP & FIREWALL.

Source: SDR UALA2013011700309
OTHER · 2013-01-15 Unresolved
ATA 7532

Part: SEAL — OUT OF POSITION (NR 1 ENGINE) · airframe 41,321 hrs · 10,159 cycles

PIECE OF ORANGE FOD IN STATOR SECTION OF NR 1 ENGINE. FOUND 2.5 BLEED VLV SEAL AT BLEED PORT 3 O'CLOCK POSITION, REMOVED SEAL PER MM 75-32-00. EXAMINE THE FORWARD EDGE OF THE FAN EXIT LINER SEGMENTS FOR DAMAGE AT EVERY A CHECK UNTIL SEAL IS REPLACED. SEAL TO BE REPLACED AT NEXT ENGINE SHOP VISIT. -INF- :ENG SER #727970 INSTALLED IN NR 1 POSITION. -INF- :MF1722 CREATED TO ACP RECHECK EVERY A-CHECK.

Source: SDR UALA2013011600282

2012

WARNING INDICATION · 2012-12-11 Unresolved
ATA 2121

Part: FAN — FAULTY (CARGO BAY) · airframe 40,958 hrs · 10,108 cycles

STATUS MESSAGE BULK CARGO FAN CB P37 F7 POPPED OUT. COLLARED CB AND CHECKED BY WD 21-26-21-001 ONLY AFFECT RELATED FAN. PARTS: 563-9037 606707-1 FAN. REMOVED AND REPLACED BULK CARGO VENTILATION FAN AS PER AMM 21-26-06 OPS CHECK GOOD. NO STATUS MSG NOTED.

Source: SDR UALA2012121207190
WARNING INDICATION · 2012-12-10 Unresolved
ATA 2121

Part: FAN — FAULTY (NR 1) · airframe 40,947 hrs · 10,107 cycles

VERY LOUD HOWL FROM AFT EXHAUST FAN OUTFLOW DOOR. ALSO LOUD IN AFT GALLEY. AFT EQ EXHAUST FAN 1 MSG DISPLAYED. REMOVED AND REPLACED NR 1 AFT EQUIPMENT - LAVATORY FAN IAW AMM, NO DEFECTS NOTED.

Source: SDR UALA2012121207175
OTHER · 2012-11-30 Unresolved
ATA 3442

Part: ANTENNA — INOPERATIVE (WEATHER RADAR) · airframe 40,833 hrs · 10,094 cycles

WX RADAR FAILURE, RTFL. PERFORMED FIM 34-43-00 TEST SHOWED WXR FAIL ANT. REPLACED WEATHER RADAR ANTENNA PER MM 34 -43-05. SYSTEM CHECK OK.

Source: SDR UALA2012113006866
OTHER · 2012-11-29 Unresolved
ATA 3350

Part: SIGN — UNSECURE (CABIN) · airframe 40,822 hrs · 10,092 cycles

OVERWING EXIT SIGN IS HANGING DOWN ROW 21. SECURED LOOSE OVERWING EXIT SIGN AT ROW 21.

Source: SDR UALA2012113006865
NO TEST · 2012-11-15 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 40,752 hrs · 10,077 cycles

SEAT 2AB, 6AB, 16AB, 18KL, 21KL, AND 38KL CEILING EMERGENCY LIGHT INOP. EA BULBS REPLACED AND TEST GOOD PER AMM ON NR HRN503885.

Source: SDR UALA2012111606618
OTHER · 2012-11-14 Unresolved
ATA 5347

Part: SEAT TRACK — DAMAGED (FUSELAGE) · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK CORRODED AT RBL 88 FROM BS 586 TO BS 590. REPAIRED SEAT TRACK PER ECRA 5300-01445 ON HAECO NR HRN502309.

Source: SDR UALA2012111406566
OTHER · 2012-11-13 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 40,752 hrs · 10,077 cycles

FLOORBEAM UPPER CHORD CORRODED FROM BL 0 TO LBL 15 AT BS 287. MAJOR REPAIR ACCOMPLISHED: REPAIRED FLOORBEAM PER SRM 53-00-51 REPAIR 1 FIG 101.

Source: SDR UALA2012111306524
OTHER · 2012-11-13 Unresolved
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · corrosion level 2 · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK CORRODED AT LBL 11 FROM BS 325-327. FABRICATED AND INSTALLED NEW SEAT TRACK PER SRM 51-10-02 AND 51-40-04.

Source: SDR UALA2012111306523
OTHER · 2012-11-13 Unresolved
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK CORRODED AT RBL 88 FROM BS 344 TO 347. FABRICATED AND INSTALLED NEW SEAT TRACK PER SRM 51-10-02 AND 51-40-05.

Source: SDR UALA2012111306522
OTHER · 2012-11-13 Unresolved
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK FLANGE CORRODED AT RBL 11 FROM BS 325-329. MAJOR REPAIR ACCOMPLISHED: FABRICATED AND REPLACED SEAT TRACK PER SRM 51-10-02 AND 51-40-05.

Source: SDR UALA2012111306521
OTHER · 2012-11-13 Unresolved
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK CORRODED AT RBL 88 FROM BS 586 TO BS 590. SEAT TRACK REPAIRED AND FASTENERS INSTALLED PER ECRA 5300-01445 ON HAECO NR HRN501053.

Source: SDR UALA2012111306526
OTHER · 2012-11-13 Unresolved
ATA 3350

Part: LIGHT — DAMAGED (CABIN) · airframe 40,752 hrs · 10,077 cycles

CABIN FLOOR EMERGENCY LIGHT DAMAGED. CABIN FLOOR EMERGENCY LIGHT ASSY REPLACED AND OPS CHECK NORMAL PER AMM.

Source: SDR UALA2012111306525
OTHER · 2012-11-02 Unresolved
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · corrosion level 2 · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK CORROSION STATION 1393 T0 1408 D=.040"W=.75" L=4" & STA 1329 TO 1348 D=.035"W=.7"L=3" & STA 1363 TO 1370 D=.045"W=.75"L=3.5" & STA 1423 TO 1426 D=.032 W=.7"L=3". ALL AT BL R88 TO R88. REPLACED SEAT TRACK IAW SRM 51-10-02 AND INSTALLED NEW SEAT TRACK IAW SRM. REPLACE SEAT TRACK STA 1207 TO 1427 IAW.

Source: SDR UALA2012110606382
OTHER · 2012-11-02 Unresolved
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · corrosion level 2 · airframe 40,752 hrs · 10,077 cycles

SEAT TRACK CORROSION STATION 1250 TO 1273 D=.034"W=.75" L=4" & STA 1283 TO 1285 D=.032"W=.7"L=2.5 & STA 1300 TO 1314 D=..038"W=.75"L=3.5". ALL AT BL R88 TO R88. REPLACED SEAT TRACK IAW SRM AND INSTALLED NEW SEAT TRACK IAW SRM. REPLACED SEAT TRACK STA 1207 TO 1427.

Source: SDR UALA2012110606383
OTHER · 2012-09-11 Unresolved
ATA 3420

Part: INDICATOR — FAULTY (ATTITUDE) · airframe 40,620 hrs · 10,046 cycles

ATT INDICATION OF STNDBY ATT IND IS ABNORMAL IN PITCH, ROLL, ETC. GYRO FLAG IS RETRACTED. SEE LOG BOOK FOR DETAILS. SHOWS 7 DEGREE LEFT BANK WHILE IN LEVEL LT. WORSE AFTER A TURN. REPLACED SAI PER AMM, OPS TESTED OKAY.

Source: SDR UALA2012091305172
OTHER · 2012-08-19 Unresolved
ATA 3442

Part: TRANSCEIVER — ERRATIC (WEATHER RADAR) · airframe 40,383 hrs · 9,982 cycles

WXR ANTENNA TILT ERRATIC. CREW COMMENTS: ANTENNA TILT DID NOT WORK IN AUTO. IN MANUAL, RETURNS DID NOT DEPICT TO CORRESPONDING TILT. REPLACED RT IAW AMM.

Source: SDR UALA2012082104654
OTHER · 2012-08-15 Unresolved
ATA 5420

Part: LATCH — DAMAGED (LT PYLON) · airframe 40,324 hrs · 9,969 cycles

LEFT INBD PYLON ACCESS PANEL AFT LATCH IS UNHOOKED. FOUND LATCH DAMAGED REPLACED LT INBOARD PYLON LATCH.

Source: SDR UALA2012081604566
WARNING INDICATION · 2012-07-21 Unresolved
ATA 3442

Part: TRANSCEIVER — FAILED (WX RADAR SYSTEM) · airframe 40,093 hrs · 9,917 cycles

WEATHER RADAR INOPERATIVE. WEATHER RADAR SYS FAULT ON EICAS NO "FAIL" MESSAGE ON EADI. NO CONTROL OF RADAR BY EITHER FIRST OFFICERS OR CAPTAINS SIDE. REPLACED WEATHER RADAR TRANSCEIVER AND GROUND TESTED OK.

Source: SDR UALA2012072404008
WARNING INDICATION · 2012-07-20 Unresolved
ATA 8012

Part: START VALVE — FAULTY (RT ENGINE) · airframe 40,089 hrs · 9,915 cycles

RT ENG STARTER EICAS. ENGINE MANUALLY STARTED. REPLACED START VALVE ASSY IAW AMM. START VALVE OPERATES OK.

Source: SDR UALA2012072404005
OTHER · 2012-07-20 Unresolved
ATA 3442

Part: TRANSCEIVER — FAULTY (WX RADAR SYS) · airframe 40,085 hrs · 9,914 cycles

WEATHER RADAR FAILS FREQUENTLY, REPLACED WEATHER RADAR TRANSCEIVER, TESTED OKAY.

Source: SDR UALA2012072404006
OTHER · 2012-07-20 Unresolved
ATA 3442

Part: DRIVE UNIT — FAILED (WX RADAR SYS) · airframe 40,089 hrs · 9,915 cycles

RADAR FAILED. WEATHER RADAR STAB MOMENTARILY ON LWR LT AND VAR. WX UPPER RT PRIOR TO FAIL. NO WEATHER RADAR FAIL MESSAGES ON SCREEN WITH WEATHER RADAR SYS STATUS MESSAGE. REPLACED THE WEATHER RADAR ANTENNA DRIVE UNIT. WEATHER RADAR OPS TEST IS GOOD.

Source: SDR UALA2012072404007
INADEQUATE Q C · 2012-07-05 Unresolved
ATA 2497

Part: CONNECTOR — MISWIRED · airframe 39,916 hrs · 9,880 cycles

WHILE TROUBLESHOOTING DF38, FOUND CONNECTOR NOT WIRED PER HOOK UP CHART PG 136. REPINNED CONNECTOR

Source: SDR UALA2012070303562
WARNING INDICATION · 2012-07-04 Unresolved
ATA 2913

Part: PUMP — FAULTY (HYD SYSTEM) · airframe 39,916 hrs · 9,880 cycles

REPEAT REPORT OF NR 2 CTR ACCOMPLISHED HYD PUMP PRESS LIGHT CAME ON DURING HEAVY DEMAND. SUPPLEMENTAL DATA, REPLACED NR 2TR ACMP HYP PUMP, OP'S AND LEAK CHK GOOD.

Source: SDR UALA2012070503584
OTHER · 2012-07-03 Unresolved
ATA 2741

Part: TRANSMITTER — FAULTY (STAB) · airframe 39,907 hrs · 9,878 cycles

FLAP AND STAB POSITION TRANSMITTER, DUE TO FLAP-STAB POSITION SENSING CIRCUIT BREAKER TRIPPING. REPLACED THE LEFT STAB POSITION TRANSMITTER M519 PER MM. REF IPC 27-48-01-001. REPLACED POSITION TRANSMITTER M519 PER MM. CIRCUIT BREAKER NOT TRIPPING.

Source: SDR UALA2012070503589
NO TEST · 2012-05-12 Unresolved
ATA 3397

Part: WIRE — BROKEN (EMERGENCY LIGHT) · airframe 39,360 hrs · 9,753 cycles

FOUND SEAT EMERGENCY LIGHT INOPERATIVE AT SEAT 33AB. FOUND BROKEN WIRE, REPLACED AND CHECKED ALL EMERGENCY LIGHTS INSIDE AND OUTSIDE OF AIRCRAFT. ALL OPERATED NORMALLY.

Source: SDR UALA2012051602793
NO TEST · 2012-05-11 Unresolved
ATA 3350

Part: BATTERY PACK — FAULTY (EMERGENCY LIGHTS) · airframe 39,351 hrs · 9,751 cycles

FWD CABIN RT SIDE EMERGENCY SEAT LIGHTS DIM. REPLACED BATTERY PACK, OPS GOOD.

Source: SDR UALA2012051102745
NO TEST · 2012-05-09 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 39,312 hrs · 9,742 cycles

FLOOR EMERGENCY LIGHT IS OUT BY LEFT AFT LAVATORY. REPLACED POWER STRIP AND LIGHT ASSY ALL CHECKED OK.

Source: SDR UALA2012051002715
NO TEST · 2012-05-08 Unresolved
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 39,312 hrs · 9,742 cycles

OUTSIDE EMERGENCY LIGHT IS OUT BY L2 DOOR. RELAMP ABOVE, LIGHT OPS TESTED OK.

Source: SDR UALA2012051002713
NO TEST · 2012-05-08 Unresolved
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 39,312 hrs · 9,742 cycles

SEAT EMERGENCY LIGHTS ARE OUT BETWEEN SEAT 20AB AND 23AB REPLACED BATTERY PACK AND OPS CHECKED GOOD IAW MM 33-51-07.

Source: SDR UALA2012051002714
NO TEST · 2012-04-30 Unresolved
ATA 2565

Part: BATTERY PACK — INOPERATIVE (ESCAPE SLIDE) · airframe 39,219 hrs · 9,723 cycles

SQUIB TEST 1 AND 2 INOPERATIVE FOR EMERGENCY ESCAPE SLIDE. REPLACED LEFT AND RIGHT OVERWING EMERGENCY ESCAPE BATTERY PACKS. SQUIB TEST 1 AND 2 CHECKED NORMAL.

Source: SDR UALA2012043002567
NO TEST · 2012-04-23 Unresolved
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT) · airframe 39,138 hrs · 9,706 cycles

EMERGENCY LIGHTS AT SEAT ROWS 20AB TO 33AB INOPERATIVE. REPLACED BATTERY PACKS, OP CHECKED GOOD.

Source: SDR UALA2012042302438
F.O.D. · 2012-04-22 Unresolved
ATA 2520

Part: CABLE — FOD (SEAT 24H) · airframe 39,130 hrs · 9,704 cycles

SEAT BACK WILL NOT RECLINE AT 24H. REMOVED DEBRIS FROM SEAT ACTUATOR CABLE.

Source: SDR UALA2012042402476
OTHER · 2012-04-15 Unresolved
ATA 2520

Part: ARMREST — MISSING (CABIN) · airframe 39,045 hrs · 9,687 cycles

NO ARM REST ON 16B. UNABLE TO LOCATE ARMCAP, TAPED OVER ARMREST TO ENSURE NO PAX HAZARD EXISTS. REPLACED ARMCAP.

Source: SDR UALA2012041702316
FLUID LOSS · 2012-04-05 Unresolved
ATA 2913

Part: PUMP — LEAKING (HYD SYSTEM) · airframe 38,951 hrs · 9,665 cycles

NR 2 ENGINE DRIVEN HYDRAULIC PUMP LEAKING. REPLACED NR 2 ENGINE DRIVEN PUMP PER MM.

Source: SDR UALA2012040502110
OTHER · 2012-04-05 Unresolved
ATA 7397

Part: CONNECTOR — LOOSE (PRESSURE SWITCH) · airframe 38,951 hrs · 9,665 cycles

NR 2 ENGINE FUEL PUMP, FUEL PRESSURE SWITCH CONNECTOR AND BACKSHELL LOOSE. REPLACE CONNECTOR AND BACKSHELL D10996 FUEL FILTER BYPASS SWITCH REF WDM 73-34-11 & IPC 73-34-0 0A-001 ITEMS 40 & 45. SEPARATE CARD WRITTEN FOR REPLACE OF DIFFERENTIAL PRESSURE SW. OP CHECK WILL BE ACP AFTER SW REPLACEMENT.

Source: SDR UALA2012040502104
OTHER · 2012-04-05 Unresolved
ATA 7397

Part: CONNECTOR — BROKEN (PRESSURE SWITCH) · airframe 38,951 hrs · 9,665 cycles

NR 2 ENG FUEL PUMP FILTER DIFFERENTIAL PRESSURE SWITCH HAS CONNECTOR RUSTED AND BROKEN OFF INSIDE. REPLACED NR 2 ENGINE FUEL PUMP PRESSURE SWITCH PER MM.

Source: SDR UALA2012040502109
OTHER · 2012-04-05 Unresolved
ATA 7797

Part: CONNECTOR — DAMAGED (NR 2 EGT HARNESS) · airframe 38,951 hrs · 9,665 cycles

NR 2 ENGINE, EGT HARNESS, W5J12, CONNECTOR BACKSHELL IS LOOSE (PLUG J12). ALL SOCKETS ARE OVAL IN CONNECTOR. DAMAGED CONNECTOR & BACKSHELL REMOVED.

Source: SDR UALA2012040502117
OVER TEMP; WARNING INDICATION · 2012-03-25 Unresolved
ATA 7797

Part: WIRE HARNESS — FAULTED (NR 2 ENGINE) · airframe 38,834 hrs · 9,640 cycles

RT ENG EGT OVER TEMPED ON TAXI. DEBRIEFED CREW AND THEY NOTED THAT THE RT EGT INDICATION PEGGED OUT AT 735 AT THRUST SETTING JUST ABOVE IDLE. EGT WAS NOT FLUCTUATING AND APPEARED TO BE JUST STUCK AT THE HIGH END READING. ALL OTHER ENGINE PARAMETERS WERE NORMAL. NR 2 ENGINE EGT HARNESS REPLACED. ACCOMPLISHED ENGINE RUN AT IDLE POWER AND AT 70% N2. EGT INDICATIONS NORMAL.

Source: SDR UALA2012032601912
WARNING INDICATION · 2012-02-29 Unresolved
ATA 3610

Part: SHUTOFF VALVE — FAULTY (BLEED AIR SYS) · airframe 38,538 hrs · 9,575 cycles

CREW REPORT: L ENG HPSOV EICAS. NO L ENG BLEED LIGHT. L ENG BLEED CLOSED PER PROCEDURE. COMPLIED WITH MEL CARD. ACCOMPLISHED BITE FAULT LH HPSOV REPLACED NR 1 ENG HPSOV IAW AMM, TESTS OKAY.

Source: SDR UALA2012022901267
OTHER · 2012-02-29 Unresolved
ATA 2312

Part: ANTENNA — FAULTY (NR 1 VHF) · airframe 38,539 hrs · 9,576 cycles

STATIC NR 1 VHF COMM RADIO MAKING COMM IMPOSSIBLE. FLYING IN PRECIP NR 2 VHF COMM CLEAR. PER LOCAL MANAGEMENT'S DIRECTIVE, REPLACED L VHF ANTENNA PER MM, USING THE ALTERNATE METHOD (NO GEL GASKET USED).

Source: SDR UALA2012030101270
WARNING INDICATION · 2012-02-26 Unresolved
ATA 3610

Part: CONTROLLER — FAULTY (BLEED AIR SYS) · airframe 38,505 hrs · 9,568 cycles

ON DESCENT L ENG HPSOV CAUTION CAME ON, WENT OUT AT 15-16 THOUSAND. LOCKED L ENG HPSOV IN CLOSED POSITION PER MEL. ACP'D AIR SUPPLY CONTROL SYSTEM BITE TEST PER MM, HAD "HPC" AND "HPSOV" FAULT. ACP'D PNEUMATIC HEALTH CK ON HPSOV-HPC AND PRV-PRC PER MM. HPC FAILED HEALTH CHECK. RPL'D NR 1 ENG HIGH PRESS CONTROLLER PER MM. RECHECKED NEW HPC WITH 118169 HEALTH CHECK TESTER. HPC PASSED, OPERATIONAL AND LEAK CHECK GOOD.

Source: SDR UALA2012022901266
WARNING INDICATION · 2012-02-23 Unresolved
ATA 3610

Part: CARD — FAULTY (BLEED AIR SYS) · airframe 38,478 hrs · 9,560 cycles

L ENG HPSOV EICAS DURING DESCENT W- BLEED LIGHT ON PNEUMATIC PANEL. RPL LEFT BLEED AIR CONTROL CARD PER MM. MSG CLEARED SYSTEM CHECKED OK.

Source: SDR UALA2012022401128
INADEQUATE Q C · 2012-02-12 Unresolved
ATA 3520

Part: OXYGEN MASK — MISINSTALLED (CABIN) · airframe 38,392 hrs · 9,538 cycles

ALL CENTER PASSENGER OXYGEN MASKS IMPROPERLY PACKED. REPACKED ALL CENTER O2 MASK.

Source: SDR UALA2012021300838
OTHER · 2012-02-12 Unresolved
ATA 5270

Part: TARGET — MISSING (E&E DOOR) · airframe 38,392 hrs · 9,538 cycles

FORWARD & MAIN E & E COMPARTMENT DOORS MISSING HY-MU TARGETS. INSTALLED AND OPS CHECKED THE HYMU TARGETS ON MAIN E&E BAY ACCESS DOOR AND FWD NOSE COMPARTMENT DOOR PER AMM AND JIC#611006011. OPS CHECKED GOOD.

Source: SDR UALA2012021300837
INADEQUATE Q C · 2012-02-12 Unresolved
ATA 3520

Part: OXYGEN MASK — MISINSTALLED (CABIN) · airframe 38,392 hrs · 9,538 cycles

ALL RIGHT PASSENGER OXYGEN MASKS IMPROPERLY PACKED. REPACKED ALL RIGHT O/B O2 MASK.

Source: SDR UALA2012021300839
OTHER · 2012-02-11 Unresolved
ATA 5270

Part: TARGET — MISSING (E&E DOOR) · airframe 38,392 hrs · 9,538 cycles

FWD AND MAIN E&E DOORS MISSING HYMU TARGETS. INSTALLED AND OPS CHECKED THE HYMU TARGETS ON MAIN E&E BAY ACCESS DOOR AND FWD NOSE COMPARTMENT DOOR. OPS CHECKED GOOD.

Source: SDR UALA2012021300824
OTHER · 2012-02-07 Unresolved
ATA 2565

Part: SLIDE — FAULTY (CABIN) · airframe 38,392 hrs · 9,538 cycles

RT OVERWING SLIDE PACK BOARD COVER RELEASE TRIGGER NOT FULLY SEATED ON ARMING CAM. REMOVED AND REPLACED RT OVERWING SLIDE.

Source: SDR UALA2012020900766
OTHER · 2012-02-02 Unresolved
ATA 4950

Part: BLEED VALVE — FAULTY (APU) · airframe 38,382 hrs · 9,535 cycles

APU BLEED VALVE WOULD NOT OPEN. REPLACED AND OPS CHECKED THE APU BLEED VALVE PER AMM AND THE IGV ACTUATOR PER AMM. OPS CHECKED GOOD.

Source: SDR UALA2012020300680

2011

WARNING INDICATION · 2011-12-21 Unresolved
ATA 7261

Part: SCAVENGE PUMP — FAILED (OIL SYSTEM) · airframe 37,917 hrs · 9,437 cycles

LOW OIL QTY REPORTED IN FLIGHT AND OIL QTY RECOVERS ON GROUND. REPLACED NR 2 ENGINE LUBE AND SCAVENGE OIL PUMP PER MM. DRY MOTOR LEAK CHECKED GOOD.

Source: SDR UALA2011122207071
WARNING INDICATION · 2011-12-20 Unresolved
ATA 7932

Part: TRANSMITTER — MALFUNCTIONED (NR 2 OIL QTY) · airframe 37,908 hrs · 9,435 cycles

NR 2 ENGINE HAS LOWER THAN NORMAL OIL QTY INDICATION DURING FLIGHT WITH OIL TEMP AND PRESSURE INDICATIONS NORMAL. REPLACED OIL QTY TRANSMITTER, OPS CHECKED GOOD.

Source: SDR UALA2011122207070
WARNING INDICATION · 2011-12-04 Unresolved
ATA 3457

Part: RECEIVER — FAILED (LEFT) · airframe 37,714 hrs · 9,395 cycles

LEFT GPS EICAS INOPERATIVE. RESET, NO HELP. INOP PER MEL. REPLACED LEFT MMR RECEIVER PER MM AND ACP TEST 30 ON MCDP, ALSO ACCOMPLISHED ILS TEST, CHECKED OKAY.

Source: SDR UALA2011120506684
WARNING INDICATION · 2011-12-02 Unresolved
ATA 2910

Part: PRESSURE SWITCH — FAILED (HYD SYSTEM) · airframe 37,702 hrs · 9,390 cycles

LEFT HYDRAULIC PRIMARY PUMP AND RUDDER RATIO EICAS CAME ON INTERMITTENTLY DURING FLIGHT AT FL 380-400. REPLACED EDP PRESSURE SWITCH, S26, OPERATIONAL CHECKED GOOD WITH ENGINE RUN. ENG CHECK GOOD.

Source: SDR UALA2011120506675
OTHER · 2011-11-07 Unresolved
ATA 3040

Part: CAP — MISSING (R1 WINDOW) · airframe 37,418 hrs · 9,328 cycles

WINDOW R1 1 WINDOW HEAT WIRE CAP MISSING. ROBBED CAP FROM L3 WINDOW. MEL L3 WINDOW HEAT. CB PULLED AND SAFETIED P37 H6. REPLACED L3 WINDOW HEAT WIRE CAP.

Source: SDR UALA2011110806087
NO TEST · 2011-11-04 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 37,386 hrs · 9,320 cycles

CEILING EMERGENCY LIGHT INOP AT SEAT 23 LT. RELAMPED, OPS GOOD.

Source: SDR UALA2011110405993
PARTIAL RPM/PWR LOSS · 2011-11-03 Unresolved
ATA 7520

Part: TUBE — CRACKED (LT ENGINE) · airframe 37,386 hrs · 9,320 cycles

NR 1 ENG SILENT SURGE. NR 1 ENG - 6EA FAN BLADES NICKED AS MARKED. INSPECTED BLENDED FAN BLADES ON NR 1 ENG WITH EDDY CURRENT PER MM. NO CRACKS FOUND OK FOR FINAL BLEND. NR 1 ENGINE LPT COOLING TUBE CRACKED COMPLETELY THROUGH. ACPD NR 1 ENG HPC DUCT VISUAL AND VSV CHK PER MM, NO DISCREPANCIES NOTED. LPT COOLING MANIFOLD CRACKED AT 8:00. RPLD LPT COOLING MANIFOLD. DURING THE T-S'S THE IP CK VALVE WAS RMVD, CKD & REINSTALLED. POSS DUCT CLAMPING, BROKEN DUCT, HOLE IN DUCT, ETC. VERIFICATION FLIGHT CONFIRMS NORMAL OPERATION OF THE SUBJECT SYSTEM(S). TRANSMISSION OF THIS MRM CODE IS CONFIRMATION THAT THE SYSTEM(S) OPERATE NORMALLY.

Source: SDR UALA2011110305950
WARNING INDICATION · 2011-10-22 Unresolved
ATA 3150

Part: WARNING LIGHT — ILLUMINATED (POSIT C2) · airframe 37,264 hrs · 9,290 cycles

CREW REPORTED AT ROTATION, ACFT ENCOUNTERED NOTICEABLE BUMP IN RUNWAY SURFACE, IMMEDIATELY FOLLOWED BY AN AIR DEMAND PUMP AND NR 2 CTR SYS ACMP LOW PRESSURE LIGHTS. ADP LOW PRESSURE LIGHT EXTINGUISHED AFTER GEAR RETRACTED AND NR 2 ACMP LOW PRESSURE LIGHT EXTINGUISHED AFTER POWER REDUCTION. ALL LOW PRESSURE LIGHTS REMAINED OUT, GEAR & FLAP OPERATION SLOW. CTR QTY NORMAL, NO CONTROL ISSUES.

Source: SDR UALA2011102405759
OTHER · 2011-10-02 Unresolved
ATA 3140

Part: DISPLAY — FAILED (COCKPIT) · airframe 37,018 hrs · 9,238 cycles

TOP EICAS BECAME BLURRY AND UNREADABLE AT 1000FT ON LANDING. CAME BACK, ON TAXI IN. REPLACED UNIT, CHECKED OKAY.

Source: SDR UALA2011100505399
OTHER · 2011-09-29 Unresolved
ATA 3460

Part: COMPUTER — FAILED · airframe 36,989 hrs · 9,232 cycles

LEFT YAW DAMPER INOPERATIVE. COMPLIED WITH MEL CARD AND LEAK CHECKED. FOUND LEFT FCC COMPUTER FAILURE THE CAUSE. REPLACED LEFT FCC PER AMM. OPS CHECKED MCDP GROUND TEST MODE 01 FCC LEFT NORMAL, AND TEST OF YAW DAMPER SYSTEM PER AMM TESTED NORMAL.

Source: SDR UALA2011100505400
OTHER · 2011-09-29 Unresolved
ATA 2720

Part: SERVO VALVE — FAILED (RUDDER) · airframe 36,989 hrs · 9,232 cycles

NO INFC FCC L RUD SERVO CMD, FAULT DURING ADFS TEST. REPLACED LEFT RUDDER ELECTRO HYDRAULIC SERVO VALVE, OPS CHECK OKAY. ACCOMPLISHED CAT III CHECK. ALL OK PER LAX MM. RETURNED AC BACK TO CAT III STATUS.

Source: SDR UALA2011100505401
OTHER · 2011-09-07 Unresolved
ATA 7397

Part: CONNECTOR — DEFECTIVE (ENGINE) · airframe 36,858 hrs · 9,202 cycles

AFTER ENG SHUTDOWN, NOTED MAINTENANCE LEVEL ECS MESSAGE R EEC C2 MESSAGE. FAULT RETURNED AFTER EEC REPLACEMENT. FOUND CONTACT PUSHED BACK IN CONNECTOR W5J12 PIN 6. REPLACED CONNECTOR, PIMU GROUND SCAN OKAY.

Source: SDR UALA2011090904896
OTHER · 2011-09-06 Unresolved
ATA 3350

Part: LIGHT — BROKEN (CABIN) · airframe 36,848 hrs · 9,200 cycles

SEAT 10B AISLE EEL LIGHT BROKEN. REPLACED EEL LIGHT, OP CHECKED GOOD.

Source: SDR UALA2011090904895
NO TEST · 2011-09-05 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 36,839 hrs · 9,198 cycles

LT AFT OVERWING SLIDE LIGHT INOPERATIVE. RELAMPED PER MM, OP CHECKS GOOD.

Source: SDR UALA2011090504775
OTHER · 2011-09-05 Unresolved
ATA 3350

Part: SCREW — STRIPPED (EXIT LIGHT) · airframe 36,839 hrs · 9,198 cycles

SCREWS STRIPED AT LT AFT OVERWING SLIDE LIGHT LENS ASSY. REPLACED LENS ASSY PER MM.

Source: SDR UALA2011090504776
NO TEST · 2011-09-05 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 36,839 hrs · 9,198 cycles

EEL LIGHT STRIP AT SEATS 2AB INOP. REPLACED LIGHT STRIP PER MM, OP CHECKS GOOD.

Source: SDR UALA2011090504774
OTHER · 2011-08-09 Unresolved
ATA 7230

Part: TAPE — TORN (LT ENGINE) · airframe 36,536 hrs · 9,131 cycles

CREW REPORT: LT ENGINE SPEED TAPE ON FAN EXIT VANE IS TORN AND MISSING PIECES. ACP'D 'RE-TAPE' OF FAN-EXIT GUIDE VANES. OK TO CONTINUE IN SERVICE. REVIEWED WITH SAMC-EMC.

Source: SDR UALA2011081004184
WARNING INDICATION · 2011-07-06 Unresolved
ATA 2100

Part: UNKNOWN — MALFUNCTIONED (EQ COOLING) · airframe 36,110 hrs · 9,037 cycles

EQ COOLING OVERHEAT. EQ COOLING INTERMITTENT OVHT IN AUTO AND STANDBY MODES, OVERRIDE SYSTEM OPERATES NORMAL. ALL MODES OPS CHECKS GOOD ON GROUND.

Source: SDR UALA2011070603338
OTHER · 2011-07-01 Unresolved
ATA 2820

Part: SWITCH — FAULTY (RT CTR TANK) · airframe 36,056 hrs · 9,027 cycles

RIGHT CENTER TANK FUEL PUMP INOPERATIVE AND DEACTIVATED. REPLACED RIGHT CENTER TANK SWITCH, OPERATIONAL CHECK OF PUMP NORMAL

Source: SDR UALA2011070103248
WARNING INDICATION · 2011-06-19 Unresolved
ATA 2121

Part: RELAY — FAILED (COOLING FAN) · airframe 35,903 hrs · 8,994 cycles

FWD EQP COOLING EICAS MSG, FLIGHT DIVERTED. REPLACED EQ COOLING SUPPLY FAN NR 1 RELAY K343. ACCOMPLISHED OPERATIONAL TEST, CHECKS OKAY.

Source: SDR UALA2011062003016
OTHER · 2011-06-10 Unresolved
ATA 3350

Part: LIGHT — UNSECURE (SEAT 1H) · airframe 35,811 hrs · 8,974 cycles

EXIT PATH LIGHT STRIP NEXT TO SEAT 1H IS LOOSE. SECURED SEAT MOUNTED LIGHT WITH INTERIM REPAIR. LIGHT WORKS AND IS VISIBLE.

Source: SDR UALA2011061002865
WARNING INDICATION · 2011-06-09 Unresolved
ATA 2121

Part: FAN — FAULTY (EQUIPEMENT BAY) · airframe 35,802 hrs · 8,972 cycles

ON LOWER EICAS, FWD EQUIPMENT EXHAUST FAN STATUS MESSAGE ON. REPLACED EQUIPMENT COOLING EXHAUST FAN AND VIBRATION MONITOR. OP'S CHECKED SYS NORMAL. NO EICAS MESSAGES OR LIGHTS.

Source: SDR UALA2011061002864
OTHER · 2011-06-08 Unresolved
ATA 3350

Part: LIGHT — LOOSE (CABIN) · airframe 35,793 hrs · 8,970 cycles

EMERGENCY LIGHT ON SIDE OF SEAT IS LOOSE 1H. SECURED LIGHT ASSY.

Source: SDR UALA2011060902835
OTHER · 2011-06-06 Unresolved
ATA 3350

Part: LIGHT — UNSECURE (CABIN) · airframe 35,773 hrs · 8,964 cycles

SEAT EEL LIGHT ON 36B FALLING OFF. REPLACED ASSY, OPS OK.

Source: SDR UALA2011060602757
OTHER · 2011-06-05 Unresolved
ATA 2300

Part: SATCOM — FAULTY (COCKPIT) · airframe 35,763 hrs · 8,962 cycles

NO COMM DISPLAYED ON ACARS DISPLAY UNIT OVER OCEAN, ACARS SENDS OK IN VHF RANGE. CREW COMMENTS: SATCOM VOICE INOP. SATCOM DATALINK INTERMITTENT. LOW GAIN DISPLAYED ON FMC SATCOM MAIN MENU. REPLACED SDU PER MM. BITE FUNCTION CKS OKAY. ESTABLISHED COMM WITH SAMC.

Source: SDR UALA2011060602767
OTHER · 2011-06-05 Unresolved
ATA 2421

Part: GENERATOR — INOPERATIVE (APU) · airframe 35,758 hrs · 8,961 cycles

APU GEN INOPERATIVE. REPLACED APU GEN PER MM.

Source: SDR UALA2011060602756
WARNING INDICATION · 2011-06-03 Unresolved
ATA 2121

Part: FAN — FAULTY (EQ BAY) · airframe 35,737 hrs · 8,956 cycles

EICAS MSG' FWD EQPT OVHT' DISPL &'OVHT' LGT ILLUM AFTER SELECTION WAS POS TO 'STBY' LGT RE-ILLUM FOLLOWING 5 MIN DELAY. SELECTION WAS POS TO 'OVRD' EICAS MESSAGE 'FWD EQPT COOLING' DISPL & 'NO COOLING' LGT. REPLACED EXHAUST FAN AND MONITOR.

Source: SDR UALA2011060302706
FLUID LOSS · 2011-05-07 Unresolved
ATA 4920

Part: APU — LEAKING (APU BAY) · airframe 35,426 hrs · 8,886 cycles

APU DRAIN SHROUD HAS MASSIVE LEAK OF OIL-LIKE FLUID. APU OIL COMING FROM VENT TUBE APU DOWN ABOUT 1-1/2 QUARTS. REVIEW HIST. (APU OIL QTY STS MSGS), IDENTIFY LEAKY DRAIN REF AMM 49-16-00 (601), IF LEAK IS NOT FROM APU DRAINS THEN MUST LOCATE LEAK & REPAIR AS REQUIRED. NOTIFY SAMC ENG CONTROLLER WITH FINDINGS. REPLACED APU DUE TO OIL LEAK FROM TURBINE VENT LINE.

Source: SDR UALA2011050902257
WARNING INDICATION · 2011-05-06 Unresolved
ATA 4990

Part: SWITCH — FAULTY (APU) · airframe 35,417 hrs · 8,883 cycles

APU OIL QTY STATUS MSG. NO LEAKS NOTED. REPLACED LOW OIL LEVEL SWITCH PER MM, OPS CHECKS GOOD AND NO MESSAGES.

Source: SDR UALA2011050902258
OTHER · 2011-04-11 Unresolved
ATA 2300

Part: SATCOM — FAULTY (COCKPIT) · airframe 35,127 hrs · 8,822 cycles

SAT VOICE LOST EICAS CONTINUOSLY DISPLAYED DURING ENTIRE FLIGHT. REPLACED SATCOM DATA UNIT. OPS NORMAL.

Source: SDR UALA2011041101752
NO TEST · 2011-04-11 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 35,127 hrs · 8,822 cycles

EMERGENCY LIGHT STRIP AT AFT LT MED NEAR LAV INOP. REPLACED EMERGENCY LIGHT PER WDM, OP CHECKS GOOD.

Source: SDR UALA2011041101754
NO TEST · 2011-04-11 Unresolved
ATA 3397

Part: WIRE — DAMAGED (EMERGENCY LIGHT) · airframe 35,127 hrs · 8,822 cycles

EMERGENCY LIGHT AT SEAT 12AB INOPERATIVE. REPAIRED WIRING UNDER SEAT 12AB PER WDM, OP CHECKS GOOD.

Source: SDR UALA2011041101753
OTHER · 2011-03-09 Unresolved
ATA 5753

Part: FAIRING — PUNCTURED (RT WING TE FLAP) · airframe 34,746 hrs · 8,741 cycles

RIGHT OTBD FLAP, INBD FLAP CANOE AFT SECTION INBD SIDE HAS PUNCTURE. APPROX 6IN FROM FWD EDGE AND 1" IN LENGTH. ONLY THRU OUTER SKIN. CANOE IS HONEYCOMB STRUCTURE. TAP TEST AND VISUAL INSPECTION OF CRACK-PUNCTURE NR 5 CANOE FAIRING. WITHIN LIMITS PER SRM. TO BE REPAIRED PER TABLE II. MADE INTERIM REPAIR WITH SPEED TAPE. REPAIR ACP MM.

Source: SDR UALA2011031001164
OTHER · 2011-03-07 Unresolved
ATA 2197

Part: CONNECTOR — BURNED (HEATER) · airframe 34,732 hrs · 8,738 cycles

HEATER NEAR DOOR 1R BLOWING COLD AIR. FOUND WIRING BURNED BEHIND RIGHT FWD DOOR HEAT SELECTOR SWITCH S940. FOUND WIRING BURNT BEHIND RIGHT FWD DOOR HEAT SELECTOR SWITCH S940. GND PIN MISSING ON R FWD DR HEATER CONNECTOR D21198P PIN 2. (WD21-45-21 SH2) BUT ON GROUND STUD HOOKUP LIST AND WIRE LIST, BOTH SHOW IT DOES NOT EXIST. NEEDS ENGINEER ASSISTANCE. REF GND STUD LIST AND WIRING LIST. NORMAL FOR THIS AIRCRAFT. CONCURRENTED WITH LINE ENGINEERING. REPLACED CONNECTOR D21200 AND RANG WIRES FROM D21200 TO D21198. ALL NORMAL. STILL WAITING FOR S940. AFTER REPLACED BURNT CONNECTOR, SWITCH S940, AND HEATER, SYSTEM OPS CHECK NORMAL.

Source: SDR UALA2011030701114
NO TEST · 2011-03-07 Unresolved
ATA 3350

Part: LIGHT — MISSING (SEAT 1F) · airframe 34,746 hrs · 8,741 cycles

SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHT(S) INOPERATIVE. SEAT 1F SEAT MOUNT MISSING LIGHT. SECURED AND TAPED WIRING. REPLACED SEAT MOUNT EMERGENCY LIGHT ASSY, OPS CHECKED NORMAL.

Source: SDR UALA2011030701115
OTHER · 2011-02-25 Unresolved
ATA 2211

Part: KNOB — BROKEN (MCP) · airframe 34,630 hrs · 8,717 cycles

KNOB ON HEADING ON MCP FELL OFF. REPLACED MODE CONTROL PANEL SYSTEM. SERVICEABLE PER MM.

Source: SDR UALA2011022800967
OTHER · 2011-02-23 Unresolved
ATA 2560

Part: SMOKE GOGGLES — BROKEN (COCKPIT) · airframe 34,603 hrs · 8,712 cycles

CREW REPORTED ONE COCKPIT SMOKE GOGGLE BROKEN. REPLACED 2ND OBSERVER SMOKE GOGGLE.

Source: SDR UALA2011022400937
OTHER · 2011-02-17 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (SEAT 35AB) · airframe 34,531 hrs · 8,696 cycles

SEAT MOUNTED EMERGENCY LIGHT INOP AT SEAT 35AB IAW A-CHECK. REPLACED LIGHT ASSY, OP CHECK NORMAL.

Source: SDR UALA2011021700822
NO TEST · 2011-02-17 Unresolved
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 34,531 hrs · 8,696 cycles

LT AND RT AISLE CEILING MOUNTED EMERGENCY INOP AT 11AB AND 11HJ. RELAMPED, OP CHECK NORMAL.

Source: SDR UALA2011021700821
WARNING INDICATION · 2011-01-25 Unresolved
ATA 2913

Part: PUMP — FAILED (LT ENGINE) · airframe 34,259 hrs · 8,639 cycles

"LT HYD PRI PUMP" EICAS MESSAGE. REPLACED LT ENG EDP IAW MM. REPLACED PRESSURE AND CASE DRAIN FILTERS. NO METAL NOTED.

Source: SDR UALA2011012500403
FLUID LOSS · 2011-01-09 Unresolved
ATA 2910

Part: MODULE — LEAKING (HYD SYSTEM) · airframe 34,105 hrs · 8,605 cycles

DRIPPING HYDRAULIC FLUID OUT OF RIGHT PYLON. REPLACED ACMP FILTER MODULE PER MM, OP CHECKED OKAY.

Source: SDR UALA2011011000148

2010

WARNING INDICATION · 2010-12-10 Unresolved
ATA 2131

Part: CONTROLLER — MALFUNCTIONED (NR 1) · airframe 33,768 hrs · 8,526 cycles

'AUTO INOP' LIGHT ILLUM EICAS MSG'CABIN AUTO INOP & CABIN ALT AUTO 1 & 2 DISPLAYED. OPS IN MANUAL MODE WAS OK. REPLACED AC MOTOR 1 AND CABIN PRESSURE CONTROLLER 1 TEST AND OPS CHECKED OK.

Source: SDR UALA2010121004521
OTHER · 2010-11-21 Unresolved
ATA 7510

Part: ANTI-ICE VALVE — FAULTY (RIGHT ENGINE) · airframe 33,568 hrs · 8,478 cycles

RIGHT ENG ANTI-ICE INTERMITTENT. VALVE FOUND FAULTY. ENG ANTI-ICE VALVE REPLACED. VALVE OPERATIONAL CHECK NORMAL.

Source: SDR UALA2010112204310
WARNING INDICATION · 2010-11-20 Unresolved
ATA 2121

Part: FAN — FAULTY (EXHAUST) · airframe 33,566 hrs · 8,477 cycles

"FWD EQ EXH FAN" MSG DISPLAYED. CANNOT GET STATUS MSG TO CLEAR. REPLACED FAN, OPS NORMAL.

Source: SDR UALA2010112204308
FLUID LOSS · 2010-11-10 Unresolved
ATA 2910

Part: O-RING — LEAKING (HYD SYSTEM) · airframe 33,456 hrs · 8,451 cycles

CTR HYD LEAK, FLIGHT DIVERTED. CENTER HYD QTY DROPPING TO .49. REFILL EICAS CENTER HYD SYS TURNED OFF. LEAKING O-RING ON RT CENTER HYDRAULIC ACCMP WAS CHANGED.

Source: SDR UALA2010111004170
OTHER · 2010-11-06 Unresolved
ATA 2432

Part: BATTERY — DISCHARGED (APU) · airframe 33,417 hrs · 8,443 cycles

FOUND APU BATTERY UNDER VOLTAGE 13V. REPLACED BATTERY, OPS CHECK OKAY. APU STARTS NORMAL

Source: SDR UALA2010110804153
FLUID LOSS · 2010-11-06 Unresolved
ATA 7310

Part: B-NUT — LEAKING (FUEL LINE) · airframe 33,422 hrs · 8,444 cycles

OIL LEAK NR 1 ENGINE AT B-NUT ON LARGE SUPPLY LINE AT FUEL OIL COOLER. SUPPLEMENTAL DATA UPDATE SECURED LINE. MOTORED NR 1 ENGINE, NO ACTIVE LEAKS NOTED AT THIS TIME.

Source: SDR UALA2010110804154
OTHER · 2010-10-13 Unresolved
ATA 8012

Part: START VALVE — INOPERATIVE (RT ENGINE) · airframe 33,164 hrs · 8,374 cycles

ACP AN OPS CHECK OF THE RIGHT ENG START VALVE PRIOR TO DEPT. MANUAL START. START VALVE PARTIALLY OPEN DURING START CYCLE. REPLACED START VALVE, TEST OKAY.

Source: SDR UALA2010101403818
OTHER · 2010-10-07 Unresolved
ATA 5410

Part: ACCESS PANEL — MISSING (NR 2 NACELLE) · airframe 33,100 hrs · 8,355 cycles

NR2 ENG 446AR STRUT ACCESS PANEL MISSING. REPLACED DOOR ASSY.

Source: SDR UALA2010100703728
OTHER · 2010-10-06 Unresolved
ATA 2560

Part: SMOKE GOGGLES — CONTAMINATED (F/O) · airframe 33,090 hrs · 8,352 cycles

F/O SMOKE GOGGLE STORAGE BIN FULL OF LIQUID. REPLACED GOGGLES. CLEANED AREA.

Source: SDR UALA2010100703723
OTHER · 2010-10-02 Unresolved
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHT) · airframe 33,060 hrs · 8,345 cycles

EMERGENCY CEILING LIGHT AT ROW 3HJ VERY DIM. CHARGED BATTERY IAW MM AND OPS CHECKED GOOD AT SEAT ROW 3HJ ON NON ROUTINE 2273N0 0151.

Source: SDR UALA2010100403670
NO TEST · 2010-10-02 Unresolved
ATA 3350

Part: LIGHT — NO TEST (COCKPIT) · airframe 33,060 hrs · 8,345 cycles

COCKPIT EMERGENCY LIGHTS FAILED OPS CHECKS. TROUBLESHOT PORTABLE FLIGHT DECK EMERGENCY LIGHT CONTROL CIRCUIT IAW WDM. REPLACED FLIGHT DECK PORTABLE EXIT LIGHT WITH A SERVICEABLE UNIT IAW MM AND OPS CHECK GOOD.

Source: SDR UALA2010100403671
NO TEST · 2010-10-02 Unresolved
ATA 3350

Part: BATTERY PACK — FAULTY (EMERGENCY LIGHTS) · airframe 33,060 hrs · 8,345 cycles

EMERGENCY LIGHTS BATTERY PACKS AT SEATS 23AB & JK, FAILED. R & R BATTERY PACKS FOR EMERGENCY LIGHTS AT SEAT ROW 23AB AND 23JK PER MM, AND OPS CHECK GOOD ON NON ROUTINE 2273N00390.

Source: SDR UALA2010100403669
NO TEST · 2010-10-02 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (SEATS 23H & 6H) · airframe 33,060 hrs · 8,345 cycles

EMERGENCY EXIT LIGHTS ON SEATS 23H AND 6H ARE INOP. R & R EMERGENCY EXIT LIGHTS AT SEATS 6H AND 23H IAW AMM. OPS CHECKED GOOD IAW AMM.

Source: SDR UALA2010100403672
OTHER · 2010-09-30 Unresolved
ATA 2150

Part: VALVE — FAILED (RT A/C PACK) · airframe 33,060 hrs · 8,345 cycles

RIGHT PACK LOW LIMIT VALVE FAILED CHECK. REMOVED AND REPLACED LOW LIMIT VALVE IAW ROUTINE TASKCARD. LEAK AND OPS PERFORMED ON TASKCARD.

Source: SDR UALA2010100103637
OTHER · 2010-09-29 Unresolved
ATA 2565

Part: SLIDE — FAULTY (L2 DOOR) · airframe 33,060 hrs · 8,345 cycles

THE L2 DOOR SLIDE CABLE NOT INSTALLED ON FWD SIDE OF SLIDE PACK AT THE GIRT BAR. REMOVED AND REPLACED L2 DOOR SLIDE PACK IAW AMM.

Source: SDR UALA2010092903608
OTHER · 2010-09-29 Unresolved
ATA 3610

Part: CONTROLLER — FAULTY (POS 2) · airframe 33,060 hrs · 8,345 cycles

NR 2 ENG HPC FAILED PNEUMATIC HEALTH CHECK. REMOVED AND REPLACED NR 2 ENG HPC, OPS CHECK GOOD IAW.

Source: SDR UALA2010092903607
OTHER · 2010-09-27 Unresolved
ATA 3610

Part: CONTROLLER — FAILED (HIGH PRESSURE) · airframe 33,060 hrs · 8,345 cycles

NR1 ENG HPC FAILED CHK. R & R NR1 ENGINE HIGH PRESSURE CONTROLLER, OPS CHECK GOOD.

Source: SDR UALA2010092803584
OTHER · 2010-09-09 Unresolved
ATA 2565

Part: WASHER — CORRODED (RT OVERWING SLID) · airframe 32,971 hrs · 8,319 cycles

RT OVERWING SLIDE COMPARTMENT FWD DOOR LATCH ACTUATOR PIVOT LINK JUST FWD OF ACTUATOR, CORRODED AT ROD END. REMOVED SURFACE CORROSION AND REPLACED WASHER.

Source: SDR UALA2010091003352
FLUID LOSS; WARNING INDICATION · 2010-09-02 Unresolved
ATA 2421

Part: FITTING — LEAKING (LT IDG) · airframe 32,914 hrs · 8,304 cycles

EICAS MESSAGE LT GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUMINATED GEN DRIVE DISCONNECTED. FOUND LT IDG OIL SERVICE FITTINGS LEAKING. ACP 5 MIN IDLE RUN RECONNECTED LT IDG AND SERVICED IDG, FREQ AT 403, VOLTS 116, OUT 87, RISE 6 RESAFTIED DISC SWITCH.

Source: SDR UALA2010090203225
OTHER · 2010-08-31 Unresolved
ATA 3610

Part: VALVE — FAULTY (APU) · airframe 32,900 hrs · 8,301 cycles

APU VALVE FAILED TO OPEN FULLY. DUCT PRESSURE ONLY 5 PSI WITH BLEED SWITCH SELECTED OPEN. REPLACED APU AIR SUPPLY SHUTOFF VALVE. OPS CKS NORMAL.

Source: SDR UALA2010090203224
FALSE WARNING · 2010-08-19 Unresolved
ATA 3420

Part: INDICATOR — FAULTY (STDBY ATTITUDE) · airframe 32,781 hrs · 8,271 cycles

STBY ATTITUDE INDCATOR INDICATES 2.5-3.0 DEGREES AND WHEN COMPARED TO ATTITUDE OF EHSI ON STBY ATTITUDE INDICATOR. REPLACED STBY ATTIDUDE INDICATOR IAW MM AND ACCOMPLISHED TEST IAW MM. INDICATOR OPS CHECKED OK.

Source: SDR UALA2010081903053
WARNING INDICATION · 2010-08-10 Unresolved
ATA 3040

Part: CONTROLLER — FAULTY (POS 1) · airframe 32,699 hrs · 8,245 cycles

WINDOW EICAS MSG DISPLAYED. SUPPLEMENTAL DATA UPDATE POSN 4 (1-L FWD,2=L SIDE,3= R FWD,4=R SIDE). INOP LGT ILLUM. INOP LGT DID NOT EXTING WHEN SW WAS RECYCLED TO OFF THEN ON. REPLACED WHCU. OPS NORMAL.

Source: SDR UALA2010081202945
NO TEST · 2010-07-22 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 32,429 hrs · 8,176 cycles

EMERGENCY EXIT LIGHT AT 21HJ IS INOPERATIVE. REPLACED LIGHT STRIP, OPS NORMAL.

Source: SDR UALA2010072202620
OTHER · 2010-06-12 Unresolved
ATA 3150

Part: COMPUTER — FAULTY (LT EICAS) · airframe 31,944 hrs · 8,057 cycles

LOWER EICAS DISPLAY BLANK. REPLACED DISPLAY NO HELP. FOUND LT CMPTR BLANKS LWR DISPLAY AFTER PWR SWITCHING,OK ON RIGHT. HAS HISTORY. EICAS COMPUTER IN FLIGHT DECK. REPLACED LT EICAS COMPUTER. OPS ARE GOOD.

Source: SDR UALA2010061402088
WARNING INDICATION · 2010-06-11 Unresolved
ATA 4960

Part: CONTROLLER — MALFUNCTIONED (APU) · airframe 31,929 hrs · 8,053 cycles

APU BITE MSG WILL NOT ERASE. REPLACED APU CONTROLLER IAW MM, CKS GOOD.

Source: SDR UALA2010061102052
OTHER · 2010-06-11 Unresolved
ATA 3510

Part: HOSE — KINKED (CREW OXYGEN) · airframe 31,929 hrs · 8,053 cycles

CAPTS O2 MASK LOSES 10 PSI EVERY :02. DURING TROUBLESHOOTING, FOUND 2ND OBSERVER'S O-2 SUPPLY HOSE KINKED, LEAKING AT CROSS THREADED TEE FTG. REPLACED SUPPLY HOSE, PCN=192-2103 P/N 38001-606. REPLACED OTBD TEE FITTING, PCN =710-2303. ACP POST INSTALLATION LEAK CHECK ON BOXES, MASKS & REPLACED HARDWARE. NO LEAKS FOUND.

Source: SDR UALA2010061102049
OTHER · 2010-06-10 Unresolved
ATA 3510

Part: OXYGEN MASK — LEAKING (COCKPIT) · airframe 31,922 hrs · 8,050 cycles

O2 MASK LEAKING. REPLACED CAPTAIN'S 02 MASK. CAPT'S O2 MASK OPS CHECKS GOOD. O2 PRESSURE IS WITHIN DISPATCH LIMITS.

Source: SDR UALA2010061102048
WARNING INDICATION · 2010-06-01 Unresolved
ATA 4960

Part: APU — FAULTY · airframe 31,809 hrs · 8,022 cycles

APU AUTO SHUTDOWN WHEN PACKS TURNED OFF, PRIOR TO ENG START. PNEU PRESS DROPS CLOSE TO ZERO WHEN PACKS SWITCHED OFF. REPEAT W-U. BIT CONTROLLER. FOUND REVERSE FLOW FAULT. REPLACED APU. CLEARED CONTROLLER FAULT. WITH ELEC AND PNEU LOAD, UNABLE TO DUPLICATE SHUTDOWN, TURNING PACKS ON-OFF AND MOTORING ENGS.

Source: SDR UALA2010060301922
OTHER · 2010-05-29 Unresolved
ATA 4920

Part: CONTROL VALVE — FAULTY (APU) · airframe 31,778 hrs · 8,016 cycles

APU SHUTDOWN DURING ENGINE START RT AFTER BOTH PACKS WERE TURNED OFF. REPLACED INLET TEMP SENSOR AND APU OPERATES NORMAL WITH LOAD ON AND OFF. AFTER AUTO SHUTDOWN AGAIN REPLACED SURGE VALVE AND FLOW CONTROL MODULE. OPS CHECKS GOOD.

Source: SDR UALA2010060101890
WARNING INDICATION · 2010-05-27 Unresolved
ATA 2120

Part: FILTER — DIRTY (CABIN AIR) · airframe 31,764 hrs · 8,012 cycles

EQ COOLING FAULT, RTFL. REMOVED EQUIPMENT COOLING AIR CLEANER, CLEANED AND REINSTALLED CLEANER. RAN EQUIPMENT COOLING IN NORMAL MODE. NO MESSAGES DISPLAYED. PERFORMED EQUIPMENT COOLING TEST. ALL FINDINGS NORMAL.

Source: SDR UALA2010052801839
SMOKE/FUMES/ODORS/SPARKS · 2010-05-25 Unresolved
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 31,742 hrs · 8,006 cycles

MID F/A REPORTED FUEL TYPE ODOR LOCATED AT SEATS 24 AND 25 H,J. REMOVED SIDEWALL PANELS LOWER DADO PANELS AND CARPET, NO FUEL SMELL EVIDENT.

Source: SDR UALA2010052601817
OTHER · 2010-05-18 Unresolved
ATA 3410

Part: INDICATOR — INTERMITTENT (EICAS) · airframe 31,663 hrs · 7,987 cycles

4 EICAS CRT GOES BLANK INTERMITTENTLY. OP NORM ON ALT COMPUTER (03=UPPER, 04=L0WER, 05=UPPR & LOWER). REPLACED LWR EICAS UNIT DISPLAY IAW MM. UNIT CHECKS OK. PAPER WORK IN LOG BK. SHIPPING CONTAINER IN BULK PIT.

Source: SDR UALA2010051901676
WARNING INDICATION · 2010-04-16 Unresolved
ATA 3610

Part: VALVE — FAULTY (POSITION 2) · airframe 31,332 hrs · 7,903 cycles

RT ENG BLEED LGT & RT ENG PRV EICAS MSG DURING CRUISE, WITH ENG BLEED SW ON, & ENG RUNNING. L & R DUCT PSI ARE. LT DUCT PRSS IS 24PSI RDUCT PRSSR IS 3 PSI. NR 2 ENG PRESS REV VALVE IS DEFECTIVE. NEEDS TO BE REPLACED. REPLACED NR 2 ENG PRESSURE REGULATING VALVE. OPS TEST ON ENG RUN-UP SUCCESSFUL.

Source: SDR UALA2010041901297
OTHER · 2010-04-14 Unresolved
ATA 7830

Part: BLOCKER DOOR — CUT (NR 1 ENGINE) · airframe 31,307 hrs · 7,896 cycles

NR 1 ENGINE BLOCKER DOOR AT THE 1130 POSITION HAS A 3 INCH LONG BY 1 INCH DEEP CUT. REMOVED BLOCKER DOOR IAW CDL 78CB INSP REMAINING AREA AND AFT FOUND NO MORE DAMAGE. REV DRAG LINK AND ASSOC HARDWARE FOR BLOCKER DOOR IN LOB BOX. REPLACED BLOCKER DOOR AT 11:30 POSITION WITH MM. OP CHECK GOOD.

Source: SDR UALA2010041401260
OTHER · 2010-04-14 Unresolved
ATA 7230

Part: CASE — FOD (COMPRESSOR) · airframe 31,307 hrs · 7,896 cycles

LOOSE METAL PIECE WEDGED AGAINST A BRACE ON THE EXHAUST SIDE OF THE LT ENGINE AT 11:30 POS PART WAS FACE OF COMPRESSOR INTERMEDIATE CASE FAIRING. REMOVED METAL. REPLACED COMPRESSOR INTERMEDIATE CASE FAIRING IAW MM.

Source: SDR UALA2010041401259
OTHER · 2010-04-02 Unresolved
ATA 3350

Part: SIGN — INOPERATIVE (EMERGENCY LIGHTS) · airframe 31,176 hrs · 7,865 cycles

FLIGHT DECK EMERGENCY EXIT LIGHT ILLUMINATES WITH POWER OFF AND EMERGENCY LIGHTS DISARMED. REPLACED SIGN, NO HELP. NO LIGHTS AT ALL. ON OR OFF. A PIECE CAME OFF OF MOUNT BASE. REPLACED MOUNT BASE AND LIGHT ASSY, OP CK OK.

Source: SDR UALA2010040501106
OTHER · 2010-03-17 Unresolved
ATA 3610

Part: VALVE — FAULTY (LT ENGINE) · airframe 31,015 hrs · 7,826 cycles

FL390 DUCT PRESS SPLIT: L= 20 PSI, R= 45-50. REPLACED PRV ON LEFT ENGINE. GROUND RUN CHKS BOTH LEFT & RIGHT DUCT PRESSURES MATCHED APPROX 33PSI.

Source: SDR UALA2010031700892
OTHER · 2010-03-14 Unresolved
ATA 4950

Part: VALVE — MALFUNCTIONED (APU) · airframe 30,991 hrs · 7,820 cycles

APU BLEED DOES NOT INCRS FOR ENG START. MAX BLEED PRESS 15 PSI. ENG MAX MOTOR 20PCT N2. WITH PACKS OFF, MOTORED ENG, REACHED 22 PERCENT N2, 20 PSI DUCT PRESSURE REACHED. REPLACED APU FLOW SENSING MODULE, NO HELP. REPLACED SURGE VALVE DUCT PRESS 32 PSI UNLOADED ENG MOTORED TO 25 PERCENT.

Source: SDR UALA2010031500872
OTHER · 2010-03-13 Unresolved
ATA 4950

Part: ACTUATOR — MALFUNCTIONED (APU) · airframe 30,977 hrs · 7,816 cycles

ENGINES STARTED NORMALLY IN DEN HOWEVER APU DUCT PRESSURE WAS 18 PSI. ACTUATOR FOUND FAULTY. REPLACED APU INLET GUIDE ACTUATOR. OPS NORMAL.

Source: SDR UALA2010031500871

2009

OTHER · 2009-12-19 Unresolved
ATA 3350

Part: LIGHT — OUT OF POSITION (SEAT 2B) · airframe 29,984 hrs · 7,592 cycles

SEAT 2B EMERGENCY LIGHT MISSING. LIGHT IS OUT OF POSITION . INSTALLED NEW SEAT EMERGENCY LIGHT STRIP. OPS CHECK GOOD.

Source: SDR UALA2009122103938
OTHER · 2009-12-19 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (GALLEY) · airframe 29,984 hrs · 7,592 cycles

MID AND AFT GALLEY FLOOR EMERGENCY LIGHT INOPERATIVE. LIGHTS FOUND DEFECTIVE. REPLACED LIGHT ASSY. TESTS OKAY.

Source: SDR UALA2009122103933
OTHER · 2009-12-06 Unresolved
ATA 2565

Part: SLIDE — OUT OF RIG (R1 DOOR) · airframe 29,843 hrs · 7,555 cycles

DOOR 1 RT SLIDE LT SIDE COMING OUT OF PAN. WILL NEED SLIDE REPLACEMENT. REPLACED & INSPECTED 1R SLIDE-RAFT ASSY INSTALLATION.

Source: SDR UALA2009120703760
OTHER · 2009-09-23 Unresolved
ATA 4960

Part: CONTROLLER — MALFUNCTIONED (APU) · airframe 29,040 hrs · 7,352 cycles

APU WON'T START. TRIED TWO TIMES. APU FAULT ON EICAS. FOUND APU BATT NORMAL AND NO FAULTS RECORDED AT APU CONTROLLER. RESET APU CONTROLLER, APU STARTS NORMAL. NFF. DEEMED OK FOR SERVICE.

Source: SDR UALA2009092503019
OVER TEMP · 2009-09-18 Unresolved
ATA 3240

Part: BRAKE — MALFUNCTIONED (MLG) · airframe 28,979 hrs · 7,341 cycles

ABORTED TAKEOFF AT APPROX 120 KNOTS DUE TO RUNWAY INCURSION. FOUND 2 FWD TIRE FUSE PLUG BLOWN, REPLACED 2 FWD TIRE. REMOVED AND REINSTALLED 2F BRAKE ASSY. REMOVED & REINSTALLED ANTI SKID TRANSDUCER. ACPD NR 1 FWD AXLE ASSY HIGH ENERGY STOP INSP NR 1F TIRE, NEEDS REPLACING DUE TO MATE TIRE ASSY BLOWN FUSE PLUG. REMOVED, INSP AND REINSTALLED TIRE ASSY. REMOVED, INSP AND REINSTALLED BRAKE ASSY. REMOVED, INSP AND REINSTALLED ANTISKID TRANSDUCER. NO DEFECTS NOTED.

Source: SDR UALA2009091802948
WARNING INDICATION · 2009-09-08 Unresolved
ATA 2121

Part: FAN — FAILED (EQUIP COOLING) · airframe 28,860 hrs · 7,317 cycles

EQ COOLING FAN FAILURE, RTFL. REPLACED FAN, OPERATES NORMAL. SAMC REQUESTS CARD REPLACEMENT BEFORE FLIGHT. REPLACED L ECS FAN CONTROL CARD PER LM REQUEST, CKS OKAY.

Source: SDR UALA2009090802799
FLUID LOSS · 2009-08-30 Unresolved
ATA 2910

Part: O-RING — DAMAGED (FILTER MODULE) · airframe 28,773 hrs · 7,296 cycles

HYD FLUID LEAKING FROM UNION ON TOP OF LT ACMP PRESSURE CASE DRAIN FILTER MODULE. REMOVED MODULE FROM PYLON. REPLACED DAMAGED O-RING FOUND AT FITTING FROM PRESSURE SENSE LINE. RE-INSTALLED MODULE.

Source: SDR UALA2009083102735
OTHER · 2009-08-18 Unresolved
ATA 3350

Part: LIGHT — MISSING (SEAT 28HJ) · airframe 28,627 hrs · 7,262 cycles

FOUND EMERGENCY LIGHT MISSING AT SEAT 28HJ. INSTALLED LIGHT ASSY, OP CHECKED GOOD.

Source: SDR UALA2009081902540
WARNING INDICATION · 2009-08-05 Unresolved
ATA 2432

Part: BATTERY — FAULTY (MAIN) · airframe 28,444 hrs · 7,221 cycles

MAIN BATTERY CHARGER STATUS MSG. REPLACED MAIN BATTERY AND CHARGER.

Source: SDR UALA2009080602391
OTHER · 2009-07-27 Unresolved
ATA 4940

Part: STARTER — FAILED (APU) · airframe 28,333 hrs · 7,194 cycles

APU FAILED TO START. APU WILL REACH 33 PERCENT AND OVER 700 EGT. FOUND STARTER CLUTCH FAILURE. INSPECTED MAG. PLUGS AND REPLACED LUBE PRESSURE AND SCAVENGE FILTERS, NO METAL NOTED. REPLACED STARTER CLUTCH. REPLACED STARTER. OPS AND LEAK CHECK'S OK.

Source: SDR UALA2009072802261
WARNING INDICATION · 2009-07-24 Unresolved
ATA 3150

Part: CIRCUIT CARD — FAULTY (EQUIP COOLING IN) · airframe 28,299 hrs · 7,185 cycles

EQUIPMENT COOLING EICAS, RTFL. SEQUENCE OF EVENT WAS FWD EQUIP OVERHEAT EICAS MESSAGE & OVERHEAT LIGHT IN AUTO; SWITCHED TO STANDBY - OVERHEAT LIGHT WENT OUT BUT CAME ON 5 MINS LATER. SWITCHED TO OVERRIDE OVERHEAT LIGHT WENT OUT BUT NO COOLING LIGHT ILLUMINATED AND EICAS MESSAGE CHANGED TO FWD EQUIP COOLING. REPLACED RELAY K626 & COOLING IND CARD M867. OK IN AIR MODE.

Source: SDR UALA2009072402207
OTHER · 2009-07-23 Unresolved
ATA 3397

Part: CONNECTOR — UNSECURE (EMERGENCY LIGHTS) · airframe 28,296 hrs · 7,183 cycles

EMERGENCY LIGHT STRIP INOP AT RT MID LAV. RE-CONNECTED EMERGENCY LIGHT STRIP CONNECTOR. OPS CHECKED OK.

Source: SDR UALA2009072402201
NO TEST · 2009-07-16 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 28,211 hrs · 7,163 cycles

SEAT 27H HAS LOOSE WIRE PROTRUDING INTO AISLE. SEAT MOUNTED EMERGENCY LIGHT INOP, WIRE STOWED. REPLACED LIGHT ASSY AND SECURED WIRE HARNESS. OPS CHECKED, OKAY.

Source: SDR UALA2009071702109
OTHER · 2009-07-16 Unresolved
ATA 2130

Part: CONTROL PANEL — DEFECTIVE (COCKPIT) · airframe 28,209 hrs · 7,162 cycles

LDG ALT KNOB SPINS BUT DOES NOT CHANGE ALTITUDE IN WINDOW. REPLACED THE CABIN ALTITUDE CONTROL PANEL.

Source: SDR UALA2009072002139
WARNING INDICATION · 2009-07-09 Unresolved
ATA 2120

Part: FILTER — DIRTY (EQ COOLING) · airframe 28,107 hrs · 7,135 cycles

EQUIP COOLING STATUS MSG. RTFL. CLEANED EQ COOLING FILTER & FWD RACK LOW FLOW DETECTOR. ACP COMPLETE EQUIP COOLING SYS TESTS. ALL STEPS PASS.

Source: SDR UALA2009070901977
OTHER · 2009-07-05 Unresolved
ATA 7421

Part: IGNITER — FAILED (NR 1 ENGINE) · airframe 28,053 hrs · 7,121 cycles

NR 1 ENG FAILED TO LIGHT WITH START SELECTION NUMBER 1 STOPPED START AND THEN STARTED L. REPLACED NR 1 ENG NR 1 EXCITER AND REPLACED BOTH NR 1 ENG IGNITERS. PRIOR TO REPLACEMENT ITEMS RAN NR 1 ENG AND DETERMINED NR 1 IGNITER FAILED, AFTER REPLACEMENTS RAN NR 1 ENG ON NR 1 & NR 2 IGNITIONS. ALL OPS NORMAL.

Source: SDR UALA2009070701950
OTHER · 2009-07-01 Unresolved
ATA 3140

Part: COMPUTER — INTERMITTENT (LT EICAS) · airframe 28,008 hrs · 7,111 cycles

LOWER EICAS SCREEN IS INTERMITTENT WHEN SELECTED TO LEFT EICAS COMPUTER. OK ON RIGHT COMPUTER. REPLACED LEFT EICAS COMPUTER. OPS CHECK NORMAL.

Source: SDR UALA2009070201910
SMOKE/FUMES/ODORS/SPARKS · 2009-06-28 Unresolved
ATA 2432

Part: BATTERY — FAULTY (APU) · airframe 27,966 hrs · 7,102 cycles

STRONG SMOKE SMELL FROM AFT RIGHT CABIN CEILING. REMOVED CEILING PANEL, OXY GEN PANELS AT 39, 40 AND 41HJ. REMOVED PSU AT 40HJ AND NO INDICATION OF OVERHEATING BUT STRONG SMOKE SMELL STILL PRESENT. FOUND APU BATTERY CAUSING SMELL. REPLACED APU BATTERY CHARGER AND APU BATTERY.

Source: SDR UALA2009062901843
OTHER · 2009-06-21 Unresolved
ATA 2350

Part: TRANSMITTER — FAILED (NR 1 AUDIO) · airframe 27,884 hrs · 7,078 cycles

VHF 1 BAD TRANSMITTER. REPLACED NR 1 AUDIO SELECT PANEL.

Source: SDR UALA2009062201754
OTHER · 2009-06-20 Unresolved
ATA 3350

Part: LIGHT — UNSECURE (CABIN) · airframe 27,873 hrs · 7,075 cycles

EMERGENCY PATH LIGHTS SEAT 2B HANGING LOOSE. SECURED LIGHT ASSY.

Source: SDR UALA2009062201750
OTHER · 2009-06-13 Unresolved
ATA 3350

Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 27,782 hrs · 7,055 cycles

EMERGENCY AISLE LIGHTS ILLUMINATED ROW 26 AND AFT WITH COCKPIT SWITCH IN ARMED POSITION. REPLACED SEAT EEL LIGHT POWER SUPPLY M1555, OPS TEST OKAY. EMERGENCY EEL SEAT LIGHTS SECTION L903 DID NOT FLICKER DURING TEST OR WITH THE SYSTEM ARMED & CHARGING.

Source: SDR UALA2009061501699
OTHER · 2009-06-09 Unresolved
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 27,737 hrs · 7,041 cycles

EMERGENCY ESCAPE PATH LIGHTS ROWS 21-36 AB FLASHING ON & OFF. REPLACED BATTERY PACKS M1559, M1560 AND M1561, LIGHTS CHECK GOOD.

Source: SDR UALA2009061001643
NO TEST · 2009-06-07 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 27,711 hrs · 7,035 cycles

EEL CYCLING ON AND OFF ROWS 26 - 36 H-J SIDE. REPLACED EEL BATTERY PACK. OPS CHECK OK.

Source: SDR UALA2009060801622
WARNING INDICATION · 2009-05-17 Unresolved
ATA 2913

Part: PUMP — FAULTY (HYD SYSTEM) · airframe 27,497 hrs · 6,973 cycles

CREW REPORTS, LEFT EDP LIGHT AND EICAS ILLUMINATED SEVERAL TIMES. FIRST OCCURRENCE INCLUDED AURAL WARNING AND MAINTENANCE PAGE AUTO RECORDED LEFT SYS PRESSURE OF 470 PSI. REPLACED LEFT ENG DRIVEN HYD PUMP. ALSO REPLACED K131 L PRESS SENSE RLY AND HYD SYS L PRES DLY MOD M921. PERFORMED OPERATIONAL TEST. OPERATED WITHIN NORMAL LIMITS.

Source: SDR UALA2009051801406
OTHER · 2009-04-18 Unresolved
ATA 3350

Part: BATTERY PACK — FAULTY (CABIN) · airframe 27,345 hrs · 6,935 cycles

SEAT 26HJ THRU 36HJ, EEL COMES ON INTERMITTENTLY. COULD NOT DUPLICATE. REPLACED EEL BATTERY PACK M1555 PRECAUTIONARY, TEST OK.

Source: SDR UALA2009042001133
INADEQUATE Q C · 2009-04-15 Unresolved
ATA 2300

Part: PANEL — FAILED (LH VHF) · airframe 27,323 hrs · 6,930 cycles

LT VHF RECEIVES BUT UNABLE TO TRANSMIT. TROUBLESHOOTING LOG 1,VHF 1- WILL RCV BUT NO SIDE TONE OR TXMISSION FR ANY POS. DISC MIKES & 4 ACP PANELS 1 AT TIME & OVHD CALL PANEL, NO HELP. BITE ON VHF 1 OK, SWAPPING 1 & 2, NO HELP. BACK IN ORIG POS BP VHF 1 OK, GNDS AT BP CK OK. CHECKED DISC AEO307 CNTR D4927. CHECKED WIRING FROM RCVR TO D FDAU, RCVR TO D4501P, ALL CHECK OK. PTT SIGNAL AT RCVR OK. FIRST OBS AUDIO PANEL & O2 MASK DISTURBED, SYS CORRECTED ITSELF. REPLACED 1ST OBS AUDIO PANEL & O2 MASK. NR 1 VHF COMM CHKS OK. ISOLATING AUDIO SELECT PANELS FROM VHF SYS BY DISCONNECTING PLUGS D4601P, D4607P & D4603P, REF WDM 23-51-14, 23-51-21, 23-51-41, COULD NOT FIND D4611P REF 23-51-31 FOR 2ND OBS, SYS REMAINED INOP, TED AUDIO ACC UNIT, NO HELP. RPL'D NR 3 O2 MASK AND AUD PNL.

Source: SDR UALA2009041701123
OTHER · 2009-04-05 Unresolved
ATA 2820

Part: SWITCH — FAULTY (RT FUEL TANK) · airframe 27,242 hrs · 6,912 cycles

RIGHT CENTER PUMP LOW PRESSURE INDICATION INOP. RIGHT CTR FUEL PUMP PRESS LIGHT NOT ON WITH PUMP SW ON AND ENG OFF. ALSO FOUND EICAS MESSAGE "R FUEL SYS PRESS" MESSAGE IS ALSO INOP. ISOLATED TO THE RIGHT FUEL TANK PUMP LOW PRESSURE SWITCH, S424. SWITCH REPLACED, OPS CHECK OK.

Source: SDR UALA2009040600986
OTHER · 2009-04-04 Unresolved
ATA 5230

Part: SEAL DEPRESSOR — DAMAGED (CARGO DOOR) · airframe 27,220 hrs · 6,908 cycles

FWD CARGO PIT, FWD SEAL DEPRESSOR DAMAGED. DAMAGED AREA MEASURES 2.5 IN X 1 IN. LOCATED 2 FT UP FROM BOTTOM OF DOOR SILL. MAJOR REPAIR ACCOMPLISHED. STRAIGHTENED DEPRESSOR, INSTALLED DOUBLER, SEALANT, FASTENERS.

Source: SDR UALA2009040600972
OTHER · 2009-03-25 Unresolved
ATA 2565

Part: BEARING — BROKEN (EVAC SLIDE) · airframe 27,045 hrs · 6,866 cycles

EMERGENCY ESCAPE SLIDE BEARINGS BROKEN. TENSION ON TENSION ROD CAUSED STRESS ON BEARINGS, CAUSING BEARINGS TO BREAK. REPLACED BEARINGS.

Source: SDR UALA2009032600893
NO TEST · 2009-03-18 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 27,045 hrs · 6,866 cycles

EMERGENCY LIGHT L334 AT L-2 DOOR INOP. RELAMPED EMERGENCY LIGHT L2 DOOR AND OPS CHECK GOOD.

Source: SDR UALA2009031900839
NO TEST · 2009-03-18 Unresolved
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 27,045 hrs · 6,866 cycles

R-2 DOOR EXTERIOR EMERGENCY LIGHT INOP. RELAMPED R2 DOOR EXTERIOR EMERGENCY LIGHT AND OPS CHECK GOOD.

Source: SDR UALA2009031900842
NO TEST · 2009-03-18 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 27,045 hrs · 6,866 cycles

LEFT OVERWING EMERGENCY LIGHT L642 INOP. RELAMPED LEFT OVERWING EMERGENCY LIGHT L642 AND OPS CHECK GOOD.

Source: SDR UALA2009031900841
WARNING INDICATION · 2009-03-18 Unresolved
ATA 2913

Part: PUMP — FAULTY (HYDRAULIC SYS) · airframe 27,047 hrs · 6,867 cycles

EDP (ENGINE DRIVEN PUMP) HYD PWR POS 1O1=L,O2=R) EDP HYD LOW PRESS LGT ILLUM. EICAS MSG DISPLAYED (L,R) HYD PRIM PUMP. EICAS MSG (L,R) HYD SYS MAINT (WAS, WAS NOT) DISPLAYED. REPLACED NR 1 ENGINE HYDRAULIC PUMP.

Source: SDR UALA2009032000852
OTHER · 2009-03-18 Unresolved
ATA 5210

Part: LATCH — FAULTY (OVERWING EXIT) · airframe 27,045 hrs · 6,866 cycles

RT OVERWING COMPT DOOR INTEGRATOR TORQUE EXCEEDS 175 INCH POUNDS. REMOVED AND REPLACED 4 EACH LATCHES AND OPS CHECK GOOD.

Source: SDR UALA2009031900843
NO TEST · 2009-03-18 Unresolved
ATA 3397

Part: CONNECTOR — NOT SEATED (CABIN) · airframe 27,045 hrs · 6,866 cycles

AFT EMERGENCY LIGHT BAR INOP. RESEATED CONNECTOR FOR AFT EMERGENCY LIGHT BAR AND OPS CHECK GOOD.

Source: SDR UALA2009031900840
OTHER · 2009-03-18 Unresolved
ATA 2565

Part: SLIDE — UNSERVICEABLE (OVERWING EXIT) · airframe 27,045 hrs · 6,866 cycles

RT OVERWING SLIDE DEPLOYMENT BAR CLAMPS ARE BROKEN AND SLIDE UNLACED. REMOVED AND REPLACED RT OFF WING SLIDE.

Source: SDR UALA2009031900846
NO TEST · 2009-03-17 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 27,045 hrs · 6,866 cycles

FWD GALLEY FLOOR EMERGENCY LIGHT BAR INOP. REPLACED AND OPS CHECKED THE EMERGENCY LIGHT BAR.

Source: SDR UALA2009031800825
NO TEST · 2009-03-15 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 27,045 hrs · 6,866 cycles

EMERGENCY EXIT LIGHT AT ROW 38H IS INOP. REMOVED BROKEN EMERGENCY EXIT LIGHT AND REPLACED WITH SERVICEABLE EXIT LIGHT AT SEAT ROW 38. OP CHECK GOOD.

Source: SDR UALA2009031600804
NO TEST · 2009-03-15 Unresolved
ATA 3350

Part: LIGHT — BROKEN (CABIN) · airframe 27,045 hrs · 6,866 cycles

CENTER LT OVERWING EMERGENCY LIGHT STRIP INOP. REMOVED BROKEN LIGHT STRIP AND REPLACED WITH SERVICEABLE LIGHT STRIP AT CENTER LT OVERWING. OPS CHECK GOOD.

Source: SDR UALA2009031600805
OTHER · 2009-03-13 Unresolved
ATA 5220

Part: CABLE — FRAYED (OVERWING EXIT) · airframe 27,045 hrs · 6,866 cycles

RT AFT OVERWING EMERGENCY EXIT EXTERNAL STEP AFT CABLE IS FRAYED. REPLACED AFT CABLE.

Source: SDR UALA2009031600788
NO TEST · 2009-03-12 Unresolved
ATA 3397

Part: CONNECTOR — NOT SEATED (CABIN) · airframe 27,045 hrs · 6,866 cycles

EMERGENCY EXIT LIGHT AT ROW 26 SEAT H IS INOP. RESEATED CONNECTOR, OPS CHECK GOOD.

Source: SDR UALA2009031300774
NO TEST · 2009-03-12 Unresolved
ATA 3350

Part: LIGHT — DISCONNECTED (CABIN) · airframe 27,045 hrs · 6,866 cycles

SEAT 21H EMERGENCY LIGHT STRIP INOP. CONNECTED LIGHT STRIP AND OPS TEST GOOD.

Source: SDR UALA2009031300776
NO TEST · 2009-03-12 Unresolved
ATA 3350

Part: LIGHT — DISCONNECTED (CABIN) · airframe 27,045 hrs · 6,866 cycles

SEAT 20A EMERGENCY LIGHT STRIP INOP. CONNECTED LIGHT STRIP AND OPS TEST GOOD.

Source: SDR UALA2009031300777
NO TEST · 2009-03-12 Unresolved
ATA 3397

Part: CONNECTOR — NOT SEATED (CABIN) · airframe 27,045 hrs · 6,866 cycles

EMERGENCY EXIT LIGHT AT ROW 11 SEAT 'B' IS INOP. RESEATED CONNECTOR AND OPS CHECK GOOD.

Source: SDR UALA2009031300773
NO TEST · 2009-03-12 Unresolved
ATA 3397

Part: CONNECTOR — NOT SEATED (CABIN) · airframe 27,045 hrs · 6,866 cycles

EMERGENCY EXIT LIGHT AT ROW 12 RIGHT SIDE INOP. RESEATED CONNECTOR, OPS CHECK GOOD.

Source: SDR UALA2009031300775
FALSE WARNING · 2009-02-10 Unresolved
ATA 3260

Part: SWITCH — OUT OF ADJUST (TAIL SKID) · airframe 26,727 hrs · 6,783 cycles

TAIL STRIKE ON TAKEOFF. RTFL. ACCOMPLISHED TAIL-TAIL SKID DRAG CHECK. ACCOMPLISHED INSPECTION. NO EVIDENCE OF INTERNAL OR EXTERNAL DAMAGE. 2/18/09: ADJUSTED RETRACT SWITCH INDICATION NORMAL.

Source: SDR UALA2009031000485

2008

INADEQUATE Q C · 2008-12-24 Unresolved
ATA 3350

Part: LIGHT — BROKEN (CABIN) · airframe 26,205 hrs · 6,660 cycles

EMERGENCY LIGHT AT 1H BROKEN PREVIOUSLY DEFERRED. SECURED LIGHT IN SEAT. INSTALLED MISSING EMERGENCY LIGHT STRIP.

Source: SDR UALA2008122407001
OTHER · 2008-11-21 Unresolved
ATA 2432

Part: BATTERY — FAULTY (MASTER) · airframe 25,820 hrs · 6,574 cycles

EICAS MESSAGE, MAIN BATTERY CHARGER WILL NOT CLEAR. REPLACED MAIN BATTERY. OPS CHECKS GOOD. MESSAGE CLEARED.

Source: SDR UALA2008112506671
NO TEST · 2008-11-01 Unresolved
ATA 3397

Part: CONNECTOR — LOOSE (CABIN) · airframe 25,600 hrs · 6,521 cycles

SEAT MOUNTED EMERGENCY LAMP STRIP AT 26HJ IS INOP. TRIED A NEW STRIP LAMP ASSY, NO HELP. REPAIRED LOOSE PLUG UNDER SEAT. OP'S CHECKED GOOD.

Source: SDR 2008UALA06346
NO TEST · 2008-11-01 Unresolved
ATA 3350

Part: POWERPACK — FAULTY (CABIN) · airframe 25,600 hrs · 6,521 cycles

RIGHT AISLE EEL PATH LIGHTS INOP AT ROW 20 - 26. FOUND BOTH PWR SUPPLIES ARE DISCONNECTED AT ROW 24, WIRING NEEDS TO BE SECURED UNDER THE SEATS. SECURED WIRING. REPLACED EEL LIGHT PWR PACK LOCATED ON FLOOR BEHIND AIR GRILL BETWEEN SEATS 23HJ AND 24HJ EEL LTS. OP CHECKS NORMAL.

Source: SDR 2008UALA06347
OTHER · 2008-10-30 Unresolved
ATA 3350

Part: LIGHT — MISSING (CABIN) · airframe 25,585 hrs · 6,517 cycles

SEAT 4H FWD EEL LIGHT MISSING. LIGHT IS OUT-OF-POSITION. REPLACED EEL LIGHT. OPS CHECK GOOD.

Source: SDR 2008UALA06342
INADEQUATE Q C; WARNING INDICATION · 2008-10-25 Unresolved
ATA 2421

Part: IDG — FAILED (LEFT) · airframe 25,533 hrs · 6,505 cycles

EICAS MSG L GEN OFF DISPLAYED. GEN OFF LIGHT ILLUM & FAILED TO RESET. GENERATOR FOUND FAULTY. REPLACED LEFT IDG. OK FOR SERVICE.

Source: SDR 2008UALA06274
OTHER · 2008-08-25 Unresolved
ATA 3397

Part: CONNECTOR — INOPERATIVE (EMERGENCY LIGHTS) · airframe 24,839 hrs · 6,323 cycles

EMERGENCY LIGHT AT SEAT 13 NOT LIGHTED WHEN LIGHTS ON. SINGLE SEAT LIGHT INOP 13H. ADJACENT LIGHTS ALL WORK OK. RESEATED CONNECTOR AT OUTBOARD SEAT. LIGHT OP CHECKS GOOD.

Source: SDR 2008UALA05471
ELECT. POWER LOSS-50 PC; WARNING INDICATION · 2008-07-30 Unresolved
ATA 2421

Part: IDG — TRIPPED (LEFT) · airframe 24,541 hrs · 6,247 cycles

L GEN TRIPPED OFF AS POWER BROUGHT UP DURING INITIAL TAKEOFF ROLL. ABORTED TAKEOFF. IDG REPLACED AND TESTED.

Source: SDR 2008UALA04075
WARNING INDICATION · 2008-07-23 Unresolved
ATA 7261

Part: WARNING LIGHT — ILLUMINATED (RT ENGINE) · airframe 24,458 hrs · 6,228 cycles

RT OIL FILTER STATUS MESSAGE. OIL FILTER STATUS MESSAGE WENT OUT AFTER 1-MINUTE WITH NO CREW ACTION. MM REPLACED THE MAIN OIL FILTER, NO METAL CHIPS FOUND. AIRCRAFT RETURNED TO SERVICE AFTER 35 MINUTE FLIGHT DELAY. NO FURTHER PROBLEMS.

Source: SDR 2008UALA03958
WARNING INDICATION · 2008-06-27 Unresolved
ATA 2150

Part: VALVE — FAULTY (COCKPIT) · airframe 24,124 hrs · 6,147 cycles

DEBRIEFED CREW AND NOTED ON APPROACH AT APPROX 4K FEET AND EQUIP COOLING POS ON OVERRIDE, THE "NO COOLING" LIGHT ILLUMINATED UNTIL ACFT BLOCKED INTO GATE. AFTER EXTENSIVE TROUBLE SHOOTING FOUND FAULTY OVERRIDE VALVE AND EQUIPMENT COOLING CARD. REPLACED COOLING CARD AND OVERRIDE VALVE. AC OK FOR SERVICE.

Source: SDR 2008UALA03599
PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2008-03-02 Unresolved
ATA 7200

Part: ENGINE — FAILED (NR 2) · airframe 22,750 hrs · 5,798 cycles

NR 2 ENGINE COMPRESSOR STALL AT 1.1 EPR ON T-O ROLL. AFTER RETURN TO THE GATE, MM FOUND METAL IN THE TAILPIPE. ENGINE REPLACED PRIOR TO FURTHER FLIGHT. ESTIMATING SHOP INPUT AT END OF MARCH. TEARDOWN FINDINGS EXPECTED BY END OF APRIL

Source: SDR 2008UALA01154
OTHER · 2008-02-22 Unresolved
ATA 3350

Part: LIGHT — MISSING (CABIN) · airframe 22,650 hrs · 5,773 cycles

EEL LIGHT ON END OF SEAT 21H MISSING. REPLACED LIGHT.

Source: SDR 2008UALA01005
INADEQUATE Q C · 2008-02-05 Unresolved
ATA 3510

Part: OXYGEN BOTTLE — LOW PRESSURE (CREW O2) · airframe 22,476 hrs · 5,727 cycles

CREW O2 NEEDS SERVICING. NOW AT 940 PSI.

Source: SDR 2008UALA00667
SMOKE/FUMES/ODORS/SPARKS · 2008-02-04 Unresolved
ATA 2120

Part: UNKNOWN — SMOKE (CABIN) · airframe 22,476 hrs · 5,727 cycles

CREW REPORTS VISIBLE SMOKE IN CABIN, MOST NOTICEABLE AT ROW 12. UNABLE TO DUPLICATE REPORTED PROBLEM. MECHANICS AND FLT CREW NOTED NO SMOKE IN CABIN ON RETURN FLIGHT FROM MCI TO ORD. NOTED FIND IN ATA CODE 210000. ACFT OK FOR SERVICE.

Source: SDR 2008UALA00638
INADEQUATE Q C · 2008-01-13 Unresolved
ATA 2420

Part: GEAR — FAILED (IDG) · airframe 22,231 hrs · 5,672 cycles

FOUND NR 1 ENG IDG DELTA P SWITCH POPPED WITH METAL IN FILTER. SUSPECT BEARING OR GEAR FAILURE DUE TO METAL FOUND IN FILTER. REPLACED NR 1 ENG IDG PER MM 24-11-01, LEAK AND OPS CHECK OK. AC OK FOR SERVICE

Source: SDR 2008UALA00219
OTHER · 2008-01-11 Unresolved
ATA 4920

Part: EEC — MALFUNCTIONED (APU ENGINE) · airframe 22,207 hrs · 5,667 cycles

APU WILL NOT START. SPEED SENSORS FAULTY DUE TO NORMAL OPERATIONS. REPLACED ENGINE CONTROL UNIT. FLIGHT CREW ACCOMPLISHED VERIFICATION FLIGHT AND SENT APPROPRIATE MESSAGE FOR NORMAL OPERATION OF THE APU. ACFT OK FOR SERVICE.

Source: SDR 2008UALA00218
INADEQUATE Q C · 2008-01-09 Unresolved
ATA 2312

Part: ANTENNA — FAULTY (VHF COMM) · airframe 22,184 hrs · 5,663 cycles

NR 1 VHF COMM XMISSIONS ABNORMAL AT ALL CREW STAT'N (1= L VHF, 2=R VHF). CREW COMMENTS: ATC HAD POOR RECEPTION USING HEADSET AND HAND MIKE. REPLACED, AND OP CHECKED LT VHF ANTENNA REF MM 23-12-03, CKS GOOD.

Source: SDR 2008UALA00172

2007

OTHER · 2007-12-10 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 21,848 hrs · 5,579 cycles

EMERGENCY LIGHTS OVER L OVERWING EXIT ROWS 15-22 ARE INOP.

Source: SDR 2007UALA05045
OTHER · 2007-12-07 Unresolved
ATA 7200

Part: ENGINE — BURNED (NR 2) · airframe 21,813 hrs · 5,571 cycles

NR 2 ENGINE IS BURNED AND CRACKED AT COMBUSTION CHAMBER BULKHEAD FWD OF AP-8 PLUG AT 7:00 POS. DAMAGE IS BEYOND LIMITS.

Source: SDR 2007UALA04990
OTHER · 2007-10-23 Unresolved
ATA 2497

Part: WIRE HARNESS — SHORTED · airframe 21,338 hrs · 5,459 cycles

LAVATORY CALL SMOKE DETECTOR SYS CIRCUIT BREAKER P34 TRIPPED. FOUND WIRE BUNDLE W820 ABOVE FWD LAV (F1) WIRES WERE BEING SMASHED BY L1 DOOR WHEN DOOR HANDLE WAS PLACED IN CLOSE POSITION. SPLICED FOLLLOWING WIRES. W 0820-201B-22, 007-22, 014-22, 013-16, 015-22, 024-20, 001-20, 00 8-22, 018-18, 019-20, 016-22, 032-20. WD33-25-11PG3. SYS CHECKED OK.

Source: SDR 2007UALA04350
FLT CONT AFFECTED · 2007-10-17 Unresolved
ATA 2211

Part: COMPUTER — UNKNOWN (AUTOPILOT) · airframe 21,315 hrs · 5,452 cycles

AIRPLANE HAS PITCH OSCILLATION (PORPOISES) WITH ANY A-P CHANNEL IN CMD AND (V-S, ALT HOLD, FLCH, VNAV) MODE SELECTED. SUSPECT THRUST MANAGEMENT COMPUTER. REPLACED THRUST MANAGEMENT COMPUTER, GROUND TEST OK. AUTOPILOT CAT III CKS GOOD. ACFT OK FOR SERVICE

Source: SDR 2007UALA04298
OTHER · 2007-10-04 Unresolved
ATA 3350

Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 21,164 hrs · 5,417 cycles

EEL LIGHTS AT SEAT 17HJ-23HJ AND EMERGENCY EXIT DOOR LIGHTS AT 17HJ AND 18HJ INOP. REPLACED EEL BATTERY, GROUND CHECK NORMAL.

Source: SDR 2007UALA04079
OTHER · 2007-10-02 Unresolved
ATA 3350

Part: LIGHT — INTERMITTENT (20HJ-25HJ) · airframe 21,134 hrs · 5,408 cycles

20HJ TO 25HJ EMERGENCY STRIP LIGHTING ON AISLE SIDE OF SEATS FLICKERS ON INTERMITTENTLY. CYCLED SWITCHES COULD NOT DUPLICATE.

Source: SDR 2007UALA04040
NO TEST · 2007-09-28 Unresolved
ATA 3350

Part: LIGHT — INTERMITTENT (RIGHT OVERWING) · airframe 21,090 hrs · 5,395 cycles

RIGHT OVERWING EMERGENCY EXIT LIGHTS ON INTERMITTENTLY IN FLT. ACCOMPLISHED CHECK OF OVERWING EXIT LIGHT. CYCLE SWITCH AND NO DEFECTS NOTED

Source: SDR 2007UALA03997
OTHER · 2007-09-28 Unresolved
ATA 3350

Part: LIGHT — MISSING (SEAT 21H) · airframe 21,084 hrs · 5,394 cycles

TECH REPORTS SEAT 21H MISSING EMERGENCY EXIT LIGHT. REPLACED MISSING LIGHT.

Source: SDR 2007UALA04007
NO TEST · 2007-09-23 Unresolved
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 21,025 hrs · 5,380 cycles

EMERGENCY FLASH LIGHT BY 1L RED LIGHT NOT BLINKING. REPLACED BATTERY, OP CHECKS OK.

Source: SDR 2007UALA03868
OTHER · 2007-09-23 Unresolved
ATA 2560

Part: HANDLE — DIRTY (R1 DOOR) · airframe 21,025 hrs · 5,380 cycles

DOOR 1R WILL NOT ARM, AND DOOR 2R ARM BUTTON WILL NOT EXTEND. FOUND OUTER DOOR HANDLE NOT STOWED ON DOOR 1-LEFT. CLEANED POP OUT BUTTON ON DOOR 1-RIGHT. DOOR ARMS PROPERLY. OK FOR SERVICE.

Source: SDR 2007UALA03869
OTHER · 2007-09-21 Unresolved
ATA 5315

Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 21,024 hrs · 5,379 cycles

CRACKED ANGLE ON FLOORBEAM BS 246, RBL 16, PULLEY SUPPORT ANGLE. REMOVED DAMAGED, FABRICATED AND INSTALLED REPLACEMENT ANGLE DOUBLER. REPAIRED IAW SRM 51-40-020. INSPECTED & OK FOR SERVICE.

Source: SDR 2007UALA03864
NO TEST · 2007-09-21 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (EXTERIOR) · airframe 21,024 hrs · 5,379 cycles

AFT LEFT EMERGENCY EXTERIOR LIGHT IS INOP. RELAMPED, EEL LIGHT OP CHECKED OK FOR SERVICE.

Source: SDR 2007UALA03867
OTHER · 2007-09-21 Unresolved
ATA 5512

Part: SKIN PANEL — DENTED (HORIZ STAB) · airframe 21,024 hrs · 5,379 cycles

RT HORIZ STABILIZER LOWER SURFACE HAS DENT AT APPROX STA 290. REMOVED DAMAGE FROM RT HORIZ LOWER SURFACE & FABRICATED REPAIR DOUBLERS AND FILLERS. INSTALLED IAW SRM 55-10-01. INSPECTED AND APPROVED FOR RETURN TO SERVICE.

Source: SDR 2007UALA03865
NO TEST · 2007-09-21 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 21,024 hrs · 5,379 cycles

EMERGENCY LIGHTS ROW 19 TO 23 LEFT ARE INOP. REMOVED AND REPLACED BATTERY PACK M1559. EEL SYSTEM OP CHECKED OK FOR SERVICE.

Source: SDR 2007UALA03866
OTHER · 2007-09-13 Unresolved
ATA 5315

Part: FLOORBEAM — CRACKED (BS 246) · airframe 21,024 hrs · 5,379 cycles

FLOORBEAM STA 246 VERTICAL STIFFENER LBL 40 CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED DAMAGED STIFFENER.

Source: SDR 2007UALA03698
OTHER · 2007-09-12 Unresolved
ATA 2565

Part: HOSE — DAMAGED (EVAC SLIDE)

HOSE WAS FOUND DAMAGED DURING HOSE TEST. 10-5-07 HOSE WAS LEAKING THRU OUTSIDE SURFACE WITHOUT VISIBLE EVIDENCE OF DAMAGE. REPLACED HOSE. SLIDE AND AIRCRAFT OK FOR SERVICE.

Source: SDR 2007UALA03686
WARNING INDICATION · 2007-08-11 Unresolved
ATA 2421

Part: IDG — FAULTY (LT ENGINE) · airframe 20,783 hrs

LEFT GEN DRIVE DISCONNECTED FOLLOWING L GEN DRIVE LIGHT ILLUMINATION. REPLACED LT IDG PER MM 24-11-01. OPS CHECK GOOD

Source: SDR 2007UALA03149
OVER TEMP; WARNING INDICATION · 2007-07-14 Unresolved
ATA 4990

Part: OIL COOLER — FAILED (APU) · airframe 20,445 hrs · 5,234 cycles

APU FAILED DURING TAXI OUT WITH FAIL LIGHT ILLUMINATED. [08-17-07] REPLACED OIL COOLER RAN APU WITH FULL LOAD 35 MIN, AND NO AUTO SHUTDOWN. OPS CHECK NORMAL AT THIS TIME

Source: SDR 2007UALA02656
WARNING INDICATION · 2007-06-20 Unresolved
ATA 2797

Part: WIRE — SHORTED (SLATS) · airframe 20,195 hrs · 5,176 cycles

L/E SLAT ASYMMETRY LIGHT AND EICAS MESSAGE ON PRIOR TO DEPARTURE. [07-20-07] FOUND SHORT IN WIRE SPLICE. REPLACED SPLICE SM7, WIRE W480-007-18, AND SHIELD ASSEMBLY. REINSTALLED D4378 CONNECT OR ASSY, AND SECURED WIRE BUNDLE. SYSTEM CHECKED OK FOR SERVICE.

Source: SDR 2007UALA02156

2006

NO TEST · 2006-12-08 Unresolved
ATA 3350

Part: LIGHT — SHORTED (AFT GALLEY) · airframe 18,005 hrs · 4,642 cycles

AFT GALLEY CROSS AISLE EEL LIGHT INOPERATIVE. AFT GALLEY CROSS AISLE EEL STRIP SECTION INOP (SHORTED INTERNALLY) IS A SMALL SECTION 15" LONG & IS ADJACENT TO AN EXISTING LONG ONE THAT IS OPERATIVE. SHORTED EEL WAS AFFECTING EEL SECTIONS 35AB THRU 41AB.REPLACED CABLE SEGMENT. OP CHECKED OK.

Source: SDR 2006UALA02354
SMOKE/FUMES/ODORS/SPARKS · 2006-08-16 Unresolved
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 16,726 hrs · 4,310 cycles

PASSENGERS REPORTED HIGH HEAT AND BURNING ODOR FROM SIDEWALL VENT. UNABLE TO LOCATE OR DUPLICATE EVENT.

Source: SDR 2006UALA01606

2004

WARNING INDICATION · 2004-02-26 Unresolved
ATA 2781

Part: WARNING SYSTEM — ACTIVATED (SLATS) · airframe 7,539 hrs · 2,062 cycles

RETURNED TO FIELD DUE TO SLAT ASYMMETRY MESSAGE. OUTBOARD SLAT NR 10 POSITION SENSOR OUT OF LIMITS. ADJUSTED SENSOR.

Source: SDR 2004UALA00170

2003

NO TEST · 2003-01-28 Unresolved
ATA 3350

Part: LIGHT — SHORTED (EMERGENCY LIGHT) · airframe 3,819 hrs · 1,129 cycles

SEAT 20 THROUGH 23 EEL LIGHTS WERE INOPERATIVE. FOUND MID-GALLEY EEL LIGHT ASSEMBLY SHORTING OUT THE SEAT EEL LIGHTS. REPLACED MID-GALLEY EEL ASSEMBLY.

Source: SDR 2003UALA00114

2002

OTHER · 2002-01-16 Unresolved
ATA 3416

Part: ALTIMETER — INACCURATE (COCKPIT) · airframe 410 hrs · 130 cycles

STANDBY ALTIMETER 500 FT DIFFERENCE FROM CAPTAIN'S AT FLIGHT LEVEL 390. 400 FT DIFFERENCE AT FLIGHT LEVEL 200 AND 60 FT DIFFERENCE ON THE GROUND. SUPPLEMENTAL DATA UPDATE CAUSE: 500 FT DIFFERENCE FROM CAPTAIN'S ALTIMETER AT FLIGHT LEVEL 390. CORRECTIVE ACTIONS: ERFORMED LEAK CHECK, REPLACED THE STBY. ALTIMETER, TESTED THE SYSTEM AT 10,000 FT. SHOP FINDINGS: DURING THE TEST, IT WAS NOTICED THAT THE VIBRATOR WAS NOISY AND THERE WAS SOME STICKING ON THE DESCENT. THE UNIT WAS IN TOLERANCE, VIBRATOR WAS REPLACED AND THE DRUM COUNTER CLEANED.

Source: SDR 2002UALA00118