N678NK
Registered owner: SPIRIT AIRLINES LLC, FL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
FA MEGAPHONE IS NOT TESTING PROPERLY-R & R MEGAPHONE. REF. AMM 25-65-51.
AFT MEGAPHONE INTERMITTENT.-R & R AFT MEGAPHONE IAW AMM 25-65-51. OPS CHECK GOOD.
R3 EMER EXIT DOOR ASSIST BOTTLE REQUIRES SERVICE -SERVICED EMER EXIT DOOR R3 ASSIST BOTTLE IAW AMM 52-22-00 LEAK CEHCK GOOD
DURING TAKKEOFF ROLL LAG ON ENG 1 IT WAS LOW SPEED ABORT TAKE OFF-R&R ELECTRONIC ENGINE CONTROL IAW AMM 73-22-34. OPS CHECK GOOD AT THIS TIME. R&R FUEL METERING UNIT IAW AMM 73-22-52. OPS CHECK GOOD AT THIS TIME. PERFORMED HIGH POWER ASSURANCE TEST IAW AMM 71-00-00. OPS CHECK GOOD AT THIS TIME. A/C GOOD FOR CONTINUE SERVICES.
AFTER T-OFF, GEAR SLOW TO RETRACT AND RECIEVED L/G DOORS NOT CLOSED MESSAGE LEFT MAIN GEAR DOOR DID NOT CLOSE.-VERIFIED MX PROCEDURES WERE FOLLOWED, NO DAMAGE OR MISALIGNMENT FOUND ON L/H MLG DOOR. HOWEVER FOUND SLACK IN LOCK WIRE (FIN 2517GM). R/R LOCKWIRE (FIN 2517GM) IAW AMM 32-12-00-040-006-A. OPS CHK GOOD. NO ECAM FAULTS, ALL INDICATIONS GREE, NO DEFECTS AT THIS TIME. ITEM REMAINS ON DMI # 68636
FWD MEGAPHONE INOP-R/R MEGAPHONE OPS CHECK OK IAW CMM 25-60-01
REF MWI 3035789-2 AFT GALLEY WORKDECK DAMAGED, DENTED AND CRACKED. RAF-01 CREATED. SDR SUBMITTED-REAPAIRED G4 GALLEY WORK DECK REF HAECO NR 40309 & EO 2533-2330 LIMITATION 3 MO
EMERGENCY MEDICAL KIT SN 0423322002 IN RH FWD O/H BIN EXPIRED. SDR CREATED -REPLACED EMERGENCY MEDICAL KIT. REF HAECO S/O 122175 NR 40193
R4 DOOR ASSIST CYL ACCUMULATOR REQ'S SERVICE.-SERVICED R4 DOOR ASSIST CYL. ACCUMULATOR IAW AMM 52-10-00.
AFT CABIN REPORTS BURNING SMELL. NO SMOKE DETECTED AND OVERHEAD BINS CHECKED FOR HOTSPOTS POTENTIAL LIGHT BALLAST ISSUE BURNING SMELL SUBSIDED WITH LIGHT OFF-PERFORMED INSP IAW TSM 05-50-00-810-931A IN DISCUSSION WITH CABIN CREW SMELL WAS ISOLATED TO AFT ROW 26 AC R/H MX REMOVED PANEL AND INSPECTED WIRING , NO FAULTS OR EFECTS . NO SMELL PRESENT DURING OPERATION SUSPECT TYPE 10 ODOR RELATED TO PASSENGER OR THREIR ITEMS
R4 DOOR ASSIST BTL REQUIRES SERVICING -SERVICED R4 DOOR ASSIST BTL PER AMM 52-10-00 TO PROPER LEVEL.
"L3 AND R3 DOOR ASSIST BOTTLES LOW-SVCD L3 AND R3 DOOR ASSISTBOTTLES IAW AMM 52-10-00. GAUGE NK 2236 CAL 02/22 TW NK 791 CAL 02/22"
SUSPECT FUME EVENT DURING DESCENT LEVELING FL 190 , UPON POWER APPICATION SUSPECTED PACK 1 TURN PACK OFF FOR REST FLT. ( PACKS A321 WITH MOD. 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/ MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )--
AFT MEGAPHONE INOP-R&R AFT MEGAPHONE IAW AMM 25-65-51. OPS CHECK OK.