Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
162 reports on file, 2020-02-06 – 2026-10-22.
Part: TRANSFER VALVE — NO DISCREPANCY (ZONE 100) · airframe 108,068 hrs · 27,596 cycles
ETOPS SIGNIFICANT EVENT - AIR RETURN UNABLE TO TRANSFER FUEL - PERFORMED OPS CHECK OF THE ENGINE CROSSFEED VALVE IAW AMM 28-22-02-724-044. NO FAULTS FOUND.
Part: FUEL SYS — MALFUNCTIONED · airframe 108,067 hrs · 27,595 cycles
ETOPS SIGNIFICANT EVENT - AIR RETURN DUE TO UNABLE TO BALANCE FUEL POSSIBLE R MAIN FUEL LEAK - PERFORMED FIM 28-21 FT 813 BLOCKS 1,3,21,23 NO DISCREPANCIES NOTED. PERFORMED DEFUEL VALVE LEAK TEST PER AMM 28-26-01/501. NO FAULTS FOUND
Part: SMOKE DETECTOR — FAULTED (ZONE 100) · airframe 107,948 hrs · 27,565 cycles
MAIN CARGO FIRE AURAL IND ON SHORT FINAL - PERFORMED CFMU BITE. FOUND MAIN CARGO SMOKE DET 1A FAULTED. R & R SMOKE DETECTOR PER AMM
Part: FIRE WARNING — FALSE ACTIVATION · airframe 107,873 hrs · 27,546 cycles
FIRE WARNING ON FINAL WHEN APPROACH MODE WAS ARMED. PERFORMED APPLICABLE FIM, NO FAULTS FOUND. ISSUE FOUND TO BE A FALSE WARNING.
Part: PROBE — DAMAGED (RT ENG EGT) · airframe 86,005 hrs · 26,881 cycles
ETOPS SIGNIFICANT REPORT, RT ENGINE EGT WENT BLANK. REPLACED RH EGT PROBE IAW AMM DUE TO FINDING ONE LOOSE STUD DURING INSPECTION.
Part: VALVE — FAULTY (LT ENGINE) · airframe 107,857 hrs · 27,543 cycles
ETOPS SIGNIFICANT REPORT, LT ENGINE PNEUMATIC HEALTH CHECK REQUIRED - PERFORMED PNEUMATIC HEALTH CHECK PER AMM, FOUND HPSOV FAULTY. REPLACED HPSOV PER AMM
Part: ACTUATOR — INOPERATIVE (OUTFLOW VALVE) · airframe 107,836 hrs · 27,537 cycles
ETOPS SIGNIFICANT REPORT - CABIN AUTO 2 SYSTEM ON MEL - REPLACED OUTFLOW VALVE ACTUATOR PER AMM
Part: ECU — INOPERATIVE (APU) · airframe 107,828 hrs · 27,536 cycles
ETOPS SIGNIFICANT REPORT - APU FAILED TO START. REPLACED APU ECU PER AMM
Part: SENSOR — INOPERATIVE (RT A/C PACK) · airframe 107,812 hrs · 27,533 cycles
ETOPS SIGNIFICANT REPORT - RIGHT PACK TEMP BITE EICAS MESSAGE. PERFORMED BITE PER AMM, FOUND COMPRESSOR OUTLET TEMP SENSOR FAULT. REPLACED TEMP SENSOR PER AMM.
Part: SENSOR — INOPERATIVE (LT A/C PACK) · airframe 107,785 hrs · 27,522 cycles
ETOPS SIGNIFICANT REPORT. STANDBY PACK TEMP CONTROL UNIT BITE FAILED. REPLACED LT PACK STANDBY COMPRESSOR OUTLET SENSOR IAW APPLICABLE AMM
Part: REHEATER — CRACKED (LT A/C PACK) · airframe 107,785 hrs · 27,522 cycles
ETOPS SIGNIFICANT REPORT, LT PACK REHEATER FOUND CRACKED. REPLACED LT PACK REHEATER IAW APPLICABLE AMM.
Part: CONTROL VALVE — INOPERATIVE (LT A/C PACK) · airframe 107,785 hrs · 27,522 cycles
ETOPS SIGNIFICANT REPORT. LEFT PACK TEMP EICAS MESSAGE, REPLACED LT PACK TEMP CONTROL VALVE IAW APPLICABLE AMM.
Part: CHIP DETECTOR — MISSING (RT ENGINE) · airframe 107,785 hrs · 27,522 cycles
ETOPS SIGNIFICANT REPORT. RT ENGINE CHIP DETECTOR MISSING DURING INSPECTION. REPLACED RT CHIP DETECTOR IAW APPLICABLE AMM
Part: VALVE — INTERMITTENT (APU) · airframe 107,785 hrs · 27,522 cycles
ETOPS SIGNIFICANT REPORT. APU PNEUMATIC SHUTDOWN VALVE INTERMITTENT. REPLACED APU PNEUMATIC SHUTOFF VALVE PER APPLICABLE AMM
Part: SWITCH — INOPERATIVE (APU) · airframe 107,785 hrs · 27,532 cycles
ETOPS SIGNIFICANT REPORT. APU PNEUMATICS INOP. REPLACED APU GEN DPI SWITCH PER APPLICABLE AMM.
Part: SENSOR — FAULTY (ZONE 100) · airframe 107,754 hrs · 27,512 cycles
ETOPS SIGNIFICANT REPORT AND EVENT. FLIGHT DECK TEMP REACHED 75 DEGREES FOR OVER AN HOUR. THE MIX MANIFOLD SENSOR WAS REPLACED. THE SUSPECTED UNSERVICEABLE MIX MANIFOLD SENSOR WAS CONFIRMED FAULTY DURING A BENCH CHECK
Part: CONTROLLER — MALFUNCTIONED (ZONE 100) · airframe 107,782 hrs · 27,521 cycles
ETOPS SIGNIFICANT REPORT AND EVENT - LEFT PACK TEMP AND CABIN ALTITUDE EICAS MESSAGE. EMERGENCY DESCENT AND DIVERSION TO ROR - PERFORMED BITE CHECK OF PACK TEMP CONTROLLER AND CABIN PRESSURE CONTROLLER PER AMM. NO FAULTS FOUND, ALL MESSAGES CLEARED.
Part: WARNING MESSAGE — ILLUMINATED (PACK TEMP) · airframe 10,779 hrs · 27,520 cycles
ETOPS SIGNIFICANT EVENT AIR RETURN. LEFT PACK TEMP, FLIGHT DECK TEMP AND CABIN ALT WARNING EICAS MESSAGES. PERFORMED BITE TEST OF PACK TEMP AND CABIN PRESSURE CONTROLLERS, NO FAULTS FOUND. AIRCRAFT RETURNED TO SERVICE.
Part: SENSOR — FAULTED (ZONE 100) · airframe 107,754 hrs · 27,512 cycles
ETOPS SIGNIFICANT REPORT AND EVENT, LT PACK TEMP AT FL 310, AIRCRAFT DIVERTED TO MNL. REPLACED LT PACK TEMP SENSOR IAW AMM.
Part: IGNITER — WORN (RT ENGINE) · airframe 107,741 hrs · 27,509 cycles
ETOPS SIGNIFICANT REPORT, RT ENGINE UPPER IGNITER PLUG WORN. REPLACED IGNITER PLUG IAW AMM.
Part: CIRCUIT CARD — INOPERATIVE (ZONE 400) · airframe 107,741 hrs · 27,509 cycles
ETOPS SIGNIFICANT REPORT, LT ENGINE FIRE LOOP 1 STATUS MESSAGE. REPLACED AFOLTS NR 1 CARD IAW AMM.
Part: ADC — FAULTED (ZONE 100) · airframe 107,741 hrs · 27,509 cycles
ETOPS SIGNIFICANT REPORT, CAPT AND FO AIRSPEED INDICATION INOPERATIVE. REPLACED LT AND RT AIR DATA COMPUTERS IAW AMM.
Part: CONTROLLER — INOPERATIVE (ZONE 100) · airframe 107,741 hrs · 27,509 cycles
ETOPS SIGNIFICANT REPORT, CABIN ALT AUTO 2 STATUS MESSAGE. REPLACED CABIN PRESSURE CONTROLLER 2 IAW AMM.
Part: SKIN — CORRODED (ZONE 600) · corrosion level 2 · airframe 107,741 hrs · 27,509 cycles
CORROSION DISCOVERED ON LT WING LOWER SKIN AND FLAP FWD SPAR. REPAIRED THE SKIN IAW EO APA-0046-017, -018 AND -035.
Part: SHEAR WEB — CORRODED (ZONE 200) · corrosion level 2 · airframe 107,741 hrs · 27,509 cycles
CORROSION DISCOVERED ON LAV FLOOR SHEAR WEB. REPAIRED THE SHEAR WEB IAW EA 26-1008, & 26-1008-SR.
Part: SKIN — CORRODED (ZONE 600) · corrosion level 2 · airframe 107,741 hrs · 25,709 cycles
CORROSION DISCOVERED ON RT WING LOWER SKIN AND FLAP UPPER SKIN. REPAIRED THE SKIN IAW EO APA-0046-019, -020, -021, -024, & -025.
Part: SKIN — CORRODED (ZONE 300) · corrosion level 2 · airframe 107,741 hrs · 27,509 cycles
CORROSION DISCOVERED ON RT HORIZONTAL STAB UPPER SKIN. REPAIRED THE STAB SKIN IAW EO APA-0046-011, -012, -013, -014, -015, & -016.
Part: SKIN — CORRODED (ZONE 100) · corrosion level 2 · airframe 107,741 hrs · 27,509 cycles
CORROSION DISCOVERED ON EMPENNAGE AREA FWD OF APU. REPAIRED IAW EO APA-0046-023.
Part: SKIN — CORRODED (ZONE 300) · corrosion level 3 · airframe 107,741 hrs · 27,509 cycles
CORROSION DISCOVERED ON LT HORIZONTAL STAB UPPER SKIN. REPAIRED THE SKIN IAW EO APA-0046-001, -002, -003, -004, -005, -006, -007, -008, -009, -010, & -036.
Part: OUTFLOW VALVE — FAULTED (ZONE 100) · airframe 107,654 hrs · 27,492 cycles
OUTFLOW REQUIRES MANUAL OPERATION TO OPEN ON THE GROUND. R & R OUTFLOW VALVE ACTUATOR IAW AMM 21-31-04.
Part: PILOT VALVE — FAULTED (RT ENGINE) · airframe 107,654 hrs · 27,492 cycles
DEFERRED RT ENG HPSOV IAW MEL 36-11-02. R & R RT ENG HIGH STAGE PILOT PER AMM 36-11-08.
Part: STARTER — FAULTY (APU) · airframe 107,634 hrs · 27,486 cycles
APU FAULT. R & R APU STARTER IAW AMM 49-41-01. OPS CHECKED NORMAL.
Part: ANTI-ICE VALVE — STICKING (LT ENGINE) · airframe 107,576 hrs · 27,474 cycles
LEFT ENG ANTI-ICE VALVE STICKING. R & R LT ENG ANTI-ICE VALVE IAW AMM 30-21-03. OP CHECKED NORMAL.
Earlier reports · 2020–2025 · 129 reports
2025
Part: LANDING GEAR — MALFUNCTIONED (ZONE 700) · airframe 107,296 hrs · 27,412 cycles
LEFT MAIN GEAR DID NOT RETRACT AFTER TAKEOFF. AIRCRAFT AIR RETURNED BACK TO HNL. MX PERFORMED FIM PROCEDURES WITH MULTIPLE FUNCTION CHECKS. NO DEFECTS NOTED. FUNCTIONAL FLIGHT PERFORMED. LANDING GEAR OPS CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE.
Part: ECU — FAULTY (ZONE 100) · airframe 106,881 hrs · 27,298 cycles
FLT: MGE820, APU FAULT, QRH PERFORMED AND RESTART OK. R & R APU ECU IAW AMM, OPS CHECK NORMAL. NO FAULTS ON ECU.
Part: SWITCH — INOPERATIVE (APU GENERATOR) · airframe 106,779 hrs · 27,271 cycles
APU GENERATOR SWITCH INOPERATIVE. REPLACED APU GENERATOR SWITCH PER AMM.
Part: MODULE — FAULTED (APU) · airframe 106,757 hrs · 27,260 cycles
APU PNEUMATICS INOP. R & R APU FLOW SENSING MODULE PER AMM. OPS CHECK NORMAL.
Part: APU — FAULTY (ZONE 100) · airframe 106,746 hrs · 27,258 cycles
APU PNEUMATICS INOP. PERFORMED AU ECU BITE PER FIM 49-22 FT 866. P2 SENSOR HARD FAULT. R/R P2 SENSOR PER AMM, NO HELP. PERFORMED WIRING CHECK OF APU SYST. PER WDM NO DEFECTS FOUND. R/R APU PER TASK CARD. OPS CHECK NORMAL.
Part: EXCITER — INOPERATIVE (RT ENGINE) · airframe 106,706 hrs · 27,248 cycles
RIGHT ENGINE IGNITION SYSTEM 1 INOP. PERFORMED OPS CHECK, FOUND SYSTEM 1 EXCITER INOP. REPLACED IGNITION EXCITER PER APPLICABLE AMM.
Part: IGNITION LEAD — DAMAGED (RT ENGINE) · airframe 106,706 hrs · 27,248 cycles
RIGHT ENGINE IGNITION SYSTEM 1 INOP. PERFORMED FIM, FOUND SYSTEM 1 IGNITION LEAD DAMAGED. REPLACED IGNITION LEAD PER APPLICABLE AMM.
Part: TRANSMITTER — FAULTY (APU OIL) · airframe 106,598 hrs · 27,220 cycles
APU OIL QTY STATUS MSG. R & R APU OIL QTY TRANSMITTER PER AMM, OPS CHECK NORMAL.
Part: APU — INOPERATIVE (ZONE 100) · airframe 106,539 hrs · 27,206 cycles
APU INOPERATIVE. R & R APU IAW AMM.
Part: SENSOR — FAULTY (LT BLEED TEMP) · airframe 106,517 hrs · 27,203 cycles
FLT NO: MGE300, LEFT ENG BLEED OFF ON T/O, AIR RETURN HNL. MX PERFORMED FIM 36-10 FT 817, FOUND LH ENG PRECOOLER OUT TEMP FAULTY. R/R FAN AIR TEMP SENSOR PER AMM. PERFORMED PNEUMATIC HEALTH CHECK NO FAULTS NOTED.
Part: WINDOW — CRACKED (L1) · airframe 106,516 hrs · 27,202 cycles
FLT NR MGE 300, L1 WINDOW CRACKED FLT 340, AIR RETURN HNL. R & R L1 WINDOW IAW AMM 56-11-01. ACFT RETURN TO SERVICE.
Part: SHUTOFF VALVE — FAULTED (RT ENGINE) · airframe 106,409 hrs · 27,176 cycles
RIGHT HPSOV FAILED PNEUMATIC HEALTH CHECK. R & R RH HPSOV PER AMM. PERFORMED HEALTH CHECK. OPS CHK OK.
Part: PILOT VALVE — FAULTED (RT ENGINE) · airframe 106,409 hrs · 27,176 cycles
RIGHT HS PILOT FAILED PNEUMATIC HEALTH CHECK. R & R RH HS PILOT PER AMM. PERFORMED HEALTH CHECK. OPS CHK OK.
Part: ISOLATION VALVE — FAULTED (ECS BAY) · airframe 106,405 hrs · 27,173 cycles
FLT NO: MGE410, BLEED ISOLATION VALVE EICAS MSG, VALVE STUCK OPEN. PERFORMED BITE FIM 36-10 FT 809. R & R ISOLATION VALVE PER 36-11-04. OPS CHECK NORMAL.
Part: DISPLAY — FAULTED (ZONE 200) · airframe 106,322 hrs · 27,150 cycles
FLT: MGE600, F/O ATTITUDE DISPLAY BLANKED OUT DURING CLIMB OUT TO FLIGHT LEVEL. AIR RETURN BACK TO HNL. R & R F/O FLAT PANEL DISPLAY PER FDS-ICA ID-07688. OPS CHECK NORMAL. ACFT RETURNED TO SERVICE.
Part: EXCITER — FAULTY (APU) · airframe 106,299 hrs · 27,146 cycles
FLT: MGE 300, ESI. APU FAULT ON TAXI IN. TROUBLESHOT PER FIM 49-11 FT 852. R/R APU IGN EXCITER. OPS CHK OK.
Part: IGNITER — FAULTED (APU) · airframe 106,299 hrs · 27,146 cycles
FLT: MGE 300, ESI. APU FAULT ON TAXI IN. TROUBLESHOT PER FIM 49-11 FT 852. R & R APU IGN PLUG. OPS CHK OK.
Part: CONVERTER — FAULTED (LT ENGINE) · airframe 106,198 hrs · 27,129 cycles
LEFT ENG EPR FLUX ON CLIMB. R/R LH ENG 14TH STAGE BLEED CONVERTER PER AMM. OPS CHECK NORMAL PER AMM.
Part: PILOT VALVE — FAULTY (LT ENGINE) · airframe 106,183 hrs · 27,126 cycles
LEFT ENG BLEED VAL ON EICAS W/ ENG ANTI ICE ON DURING CLIMB. PERFORMED PNEUMATIC HEALTH CHECK PER AMM. HS PILOT FAILED TEST. R/R HS PILOT PER AMM. OPS CHECK OK.
Part: CONVERTER — LEAKING (LT ENGINE) · airframe 106,172 hrs · 27,118 cycles
FOUND FUEL LEAK AT THE LH ENG 14TH STAGE BLEED CONVERTER. R/R LH ENG 14TH STAGE BLEED CONVERTER PER AMM. OPS CHECK NORMAL PER AMM NO LEAKS FOUND.
Part: ACTUATOR — LEAKING (LT ENGINE) · airframe 106,172 hrs · 27,118 cycles
FOUND FUEL LEAK AT THE LH ENG TURBINE COOLING ACTUATER. R/R LH ENG TURBINE COOLING ACTUATER (TCA) PER AMM. OPS CHECK NORMAL PER AMM NO LEAKS FOUND.
Part: CONTROLLER — FAILED (LT ENGINE) · airframe 106,035 hrs · 27,084 cycles
FLT NR: MGE 411. ESI - LH ENG BLEED FLUCTUATING ON DECENT. REVERSE FLOW CHECK CONTROLLER (RFCC) FAILED DURING PNEUMATIC HEALTH CHECK. R/R RFCC PER AMM.
Part: REGULATOR — FAULTED (LT ENGINE) · airframe 106,028 hrs · 27,209 cycles
MX INSPECTION. ESI - PNEUMATIC HEALTH CHECK REQUIRED. FOUND FAULTY PRSOV REGULATOR. R & R PRSOV REGULATOR PER AMM.
Part: PILOT VALVE — FAULTED (LT ENGINE) · airframe 106,028 hrs · 27,209 cycles
MX INSPECTION. ESI - PNEUMATIC HEALTH CHECK REQUIRED. HIGH STAGE PILOT FAILED PNEUMATIC SYSTEM DYNAMIC TEST. R & R HIGH STAGE PILOT PER AMM.
Part: SHUTOFF VALVE — FAULTED (LT ENGINE) · airframe 106,028 hrs · 27,209 cycles
FLT: MGE305. ETOPS EVENT - LH ENG BLEED OFF EICAS MSG DURING CLIMB. AIRCRAFT RETURNED TO GUM. FOUND FAULTY PRSOV. R & R LH ENG PRSOV PER AMM.
Part: BLEED VALVE — FAULTED (LT ENGINE) · airframe 106,027 hrs · 27,078 cycles
FLT: MGE 410/411. LH ENG BLEED DUCT PRESS FLUCTUATING ON DESCENT. R/R LH ENG 14TH STAGE BLEED VALVE PER AMM.
Part: MODULATING VALVE — FAULTED (LT ENGINE) · airframe 106,027 hrs · 27,078 cycles
FLT: MGE 410/411. LEFT PACK OFF ON LANDING. R/R FAN AIR MODULATING VALVE (FAMV) PER AMM.
Part: ANTI-ICE VALVE — FAULTY (LT ENGINE) · airframe 106,027 hrs · 27,078 cycles
LH ENG ANTI ICE EICAS. R/R LH ENG INLET TAI VALVE PER AMM.
Part: VALVE — FAULTED (LT A/C PACK) · airframe 106,020 hrs · 27,203 cycles
FLT: MGE301 - LH PACK OFF, LH PACK TEMP EICAS. REPLACED LH PACK LOW LIMIT VALVE PER AMM.
Part: VALVE — FAULTY (LT A/C PACK) · airframe 106,020 hrs · 27,203 cycles
CABIN TEMP EXCESSIVELY HOT. R/R LH TRIM AIR PRSOV PER AMM.
Part: VALVE — FAULTED (LT A/C PACK) · airframe 106,018 hrs · 27,072 cycles
FLT NR MGE411. CABIN TEMP EXCESSIVELY HOT. R/R PERFORMED FIM 21-51 FT 803 FOR PACK TEMP. CONTROLLER BITE. FOUND LH LOW LIMIT VALVE FLAG. R/R LOW LIMIT VALVE PER AMM 21-51-11/201.
Part: SHUTOFF VALVE — FAULTED (LT ENGINE) · airframe 106,020 hrs · 27,073 cycles
FLT MGE301 - ETOPS EVENT (AIRCRAFT AIR RETURN) FOUND LH ENG PRSOV FAULTY. R/R LH ENG PRSOV PER AMM.
Part: PILOT VALVE — FAULTED (LT ENGINE) · airframe 105,956 hrs · 27,064 cycles
FLT NO: MGE411 - ESI (ETOPS) LH BLEED OFF ON CLIMB. REPLACED LH HP PILOT PER APPLICABLE AMM.
Part: APU — FAULTY (ZONE 100) · airframe 105,833 hrs · 27,024 cycles
FLT NO: N/A (MX INSP) ESI - APU BLEED INOP. R/R APU PER AMM 49-11-01. OPS CHECK NORMAL.
Part: SURGE VALVE — FAULTY (APU) · airframe 105,833 hrs · 27,024 cycles
FLT NO: N/A (MX INSP) ESI - APU AUTO SHUTDOWN. R/R APU SURGE VALVE. OPS CHECK NORMAL.
Part: CHECK VALVE — WORN (APU) · airframe 105,804 hrs · 27,019 cycles
FLT NO: N/A (MX INSP). ESI - APU CHECK VALVE WORN. R/R APU BLEED AIR CHECK VALVE PER AMM 36-11-11.
Part: SENSOR — FAULTY (APU) · airframe 105,804 hrs · 27,019 cycles
FLT NO: N/A (MX INSP). ESI - APU BLEED INOP. R/R THE INLET PRESSURE SENSOR (P2) PER AMM 49-61-04. OPS CHECK GOOD.
Part: MODULE — FAULTY (APU BLEED) · airframe 105,713 hrs · 27,000 cycles
FLT: N/A (MX INSP) ESI - NO APU BLEED. REMOVED AND REPLACED FLOW SENSING MODULE PER AMM.
Part: START VALVE — INOPERATIVE (RT ENGINE) · airframe 105,666 hrs · 26,988 cycles
RT STARTER VALVE INOP. RT STARTER VALVE INOP. R/R RT STARTER VALVE PER AMM.
2024
Part: MOTOR — INOPERATIVE (OUTFLOW VALVE) · airframe 104,841 hrs · 26,804 cycles
FLT NO:N/A (MX INSP.) ESI - MULTIPLE "CABIN ALT AUTO 2" EICAS MESSAGES. R/R #2 OUTFLOW VALVE ACTUATOR AC MOTOR PER AMM 21-31-05. OPS CHECK NORMAL.
Part: ACTUATOR — LEAKING (THRUST REVERSER) · airframe 104,746 hrs · 26,776 cycles
FLT NO: N/A (MX INSP). ESI - LH ENG UPPER OUTBOARD T/R ACTUATOR LEAKING. R/R LH ENG UPPER OUTBOARD T/R ACTUATOR PER AMM 78-31-13. OPS CHECK NORMAL. NO LEAKS NOTED.
Part: SHUTOFF VALVE — INOPERATIVE (LT ENGINE) · airframe 104,679 hrs · 26,761 cycles
FLT NO: N/A. MEL 36-11-02. ESI - LH BLEED VALVE FAILED TO OPEN WITH DE-ICE ON. R/R LH ENG HPSOV PER AMM 36-11-07. OPS CHECK NORMAL.
Part: MOTOR — FAULTED (OUTFLOW VALVE) · airframe 104,600 hrs · 26,748 cycles
FLT NO: N/A (MX INSP.) ESI - OUTFLOW VALVE ACT. AC MOTOR FAULT HISTORY. R/R SYS 1 OUTFLOW VALVE ACT. AC MOTOR PER AMM 21-31-05-004-001.
Part: TRANSCEIVER — INOPERATIVE (HF COMMS) · airframe 104,596 hrs · 26,745 cycles
FLT NO: N/A (MX INSP.) ESI - RT HF INOP. R/R RT HF COMM TRANSCEIVER PER AMM 23-11-03.
Part: IGNITION LEAD — FAILED (APU) · airframe 104,445 hrs · 26,703 cycles
FLT NO: N/A (MX INSP.). ESI - APU FAILED TO START. R/R APU IGNITION LEAD, OPS CHECK GOOD.
Part: IGNITER — FAILED (APU) · airframe 104,445 hrs · 26,703 cycles
FLT NO: N/A (MX INSP.). ESI - APU FAILED TO START. R/R APU IGNITOR PLUG, OPS CHECK GOOD.
Part: EXCITER — FAILED (APU) · airframe 104,445 hrs · 26,703 cycles
FLT NO: N/A (MX INSP.) ESI - APU FAILED TO START. R/R APU IGNITION EXCITER, OPS CHECK GOOD.
Part: APU — INOPERATIVE (ZONE 100) · airframe 104,426 hrs · 26,699 cycles
FLT NO: N/A (MX INSP.) ESI - APU INOP. R/R APU.
Part: STARTER — FAILED (APU) · airframe 104,407 hrs · 26,693 cycles
FLT NO: N/A. MX INSP. ESI - APU FAILED TO START. R/R APU STARTER OPS CHECK GOOD.
Part: FMC — FAULTY (RIGHT) · airframe 104,399 hrs · 26,688 cycles
RIGHT FMC INOP. R/R RIGHT FMC.
Part: STARTER — INOPERATIVE (APU) · airframe 104,276 hrs · 26,665 cycles
FLT NO: MGE301 - ESI. APU WILL NOT START. REPLACED APU STARTER
Part: FMC — FAILED (RIGHT) · airframe 104,116 hrs · 26,636 cycles
ESI - RH FMC FAILED. REPLACED RH FMC PER AMM.
Part: PITOT HEAD — FAULTY (RIGHT) · airframe 103,944 hrs · 26,603 cycles
FLT NO: MGE300. ESI - RH AUX PITOT EICAS MSG AFTER LANDING. R/R RH AUX PITOT PROBE TUBE PER AMM 34-11-01.
Part: VALVE — FAULTY (PACK LOW LIMIT) · airframe 103,853 hrs · 26,586 cycles
FLT NO: N/A (MX INSP) ESI - LEFT PACK BITE ON EICAS. R/R LOW LIMIT VALVE.
Part: EEC — FAULTY (RT ENGINE) · airframe 1,034,768 hrs · 26,572 cycles
FLT NO: N/A (MX FINDING) ESI - R ENG EEC SECONDARY CHANNEL BLANK. REPLACED R ENG EEC PER AMM 73-21-04.
Part: EGT INDICATION — READS HIGH (RT ENGINE) · airframe 103,756 hrs · 26,568 cycles
FLT NO: N/A (MX FINDING) ESI - R ENGINE REPLACEMENT REQUIRED. REPLACED R ENG PER TASK CARD 71-999-00-01. PERFORMED PERFORMANCE TEST PER AMM 71-00-00-725-145-P00. OPS CHECK GOOD. NO LEAKS NOTED.
Part: HOUSING — LEAKING (NR 2 DEOILER) · airframe 103,667 hrs · 26,541 cycles
FLT: N/A (MX INSP.) ESI - FOUND LEAK AT R ENG DEOILER HOUSING DURING WET MOTOR. R/R R ENG DEOILER HOUSING PER AMM 72-61-10.
Part: BLADE — OUT OF LIMITS (LT ENGINE FAN) · airframe 103,653 hrs · 26,539 cycles
FLT: N/A (MX INSP). ESI - L ENG #8 FAN BLADE NICK OUT OF LIMITS, REQ'S REPLACEMENT. R/R #8 FAN BLADE PER AMM 72-31-02.
Part: BLADE — OUT OF LIMITS (LT ENGINE FAN) · airframe 103,653 hrs · 26,539 cycles
FLT: N/A (MX INSP). ESI - L ENG #26 FAN BLADE NICK OUT OF LIMITS, REQ'S REPLACEMENT. R/R #26 FAN BLADE PER AMM 72-31-02.
Part: SENSOR — FAULTY (RT A/C PACK) · airframe 103,479 hrs · 26,501 cycles
FLT NO: MGE305. ESI - RIGHT PACK INOP. REPLACED RH PACK COMPRESSOR SENSOR.
Part: IDG — LEAKING (R ENGINE) · airframe 103,479 hrs · 26,501 cycles
FLT NO: N/A (MX FINDING). ESI - OIL LEAKING FROM RH ENG DRAIN MAST. REPLACED RH IDG.
Part: BLOWER — INOPERATIVE (FWD CRGO SMK DET) · airframe 103,250 hrs · 26,460 cycles
FLT: N/A (MX INSP). ESI - FWD DET FAN STATUS MSG ON EICAS. FWD CARGO SMOKE DET BLOWER REQ'S REPLACEMENT. R/R FWD CARGO SMOKE DET BLOWER PER AMM 26-16-02.
Part: STARTER — BURNED (APU) · airframe 103,149 hrs · 26,442 cycles
FLT: N/A (MX FINDING). ESI - APU FAULT. T/S PER FIM. FOUND APU STARTER BURNED. REPLACED APU STARTER PER AMM.
2023
Part: ECU — FAULTY (APU) · airframe 103,119 hrs · 26,437 cycles
FLT: N/A (MX FINDING). ESI - APU BLEED INOP. REPLACED APU ECU PER AMM. APU BLEED CONFIRMED OPERATIONAL.
Part: FCU — FAULTY (L ENG) · airframe 102,881 hrs · 26,392 cycles
FLT. NO.: MGE300. ESI - ENGINE CONTROL STATUS MESSAGE. PERFORMED FIM 71-01 FT 802. FOUND P AND S FCU/EEC EPCS MSG. R/R L ENG FCU PER AMM 73-21-01. PERFORMED AMM TEST 15 PER AMM TASK 71-00-00-735-328-P00. OPS CHECK GOOD.
Part: CONTROLLER — FAULTY (R ENG) · airframe 102,764 hrs · 26,365 cycles
FLT NO: MGE 301. ESI - RH ENG EGT AT 520 IDLE POWER DURING TAXI. R/R HCC PER AMM 75-24-03. PERFORMED ENG RUN TEST 6 AND TEST 13. NO DEFECTS NOTED PER AMM 71-00-00.
Part: LCCA — FAULTY (R ENG) · airframe 102,764 hrs · 26,365 cycles
FLT NO: MGE301. ESI - RH ENG EGT AT 520 IDLE POWER DURING TAXI. R/R LCC PER AMM 75-24-01 PERFORMED ENG RUN TEST 6 AND TEST 13. NO DEFECTS NOTED PER AMM 71-00-00.
Part: INDICATOR — FAULTY (RT FUEL CELL) · airframe 102,551 hrs · 26,331 cycles
FLT NO: N/A (MX INSP.) ESI - RH FUEL TANK FQIS LOAD SELECT IND. R/R RH FUEL TANK FQIS LOAD SELECT IND. PER AMM 28-41-06.
Part: BLOCKER DOOR — DAMAGED (THRUST REVERSER) · airframe 102,551 hrs · 26,332 cycles
FLT NO: N/A (MX INSP.) ESI - LH ENG T/R BLOCKER DOOR DAMAGED. R/R LH ENG T/R BLOCKER DOOR PER AMM 78-31-10.
Part: INDICATOR — FAULTY (ZONE 621) · airframe 102,551 hrs · 26,331 cycles
FLT NO: N/A. (MX INSP.) ESI - RH FUEL TANK FQIS LOAD SELECT INDICATOR INOP. R/R RH FUEL TANK FQIS LOAD SELECT INDICATOR PER AMM 28-41-06.
Part: BLEED VALVE — LEAKING (L ENG) · airframe 102,348 hrs · 26,282 cycles
FLT NO: N/A (MX INSP.) ESI - FUEL LEAK AT LH ENG 2.5 BLEED VALVE. REMOVED AND REPLACED LH ENG 2.5 BLEED VALVE PER AMM 75-32-01, LEAK CHECK GOOD, PERFORMED 2.5 BLEED TEST PER AMM 71-00-00.
Part: SWITCH — FAULTY (STAB TRIM) · airframe 102,021 hrs · 26,215 cycles
FLT NO: MGE301. EVENT - LP62288 ITEM 1 - STAB TRIM STUCK WOULDN'T MOVE NOSE UP. FLT CREW DECLARED EMERGENCY INTO HNL. FOUND ALTERNATE STAB TRIM SWITCH FAULTY. REMOVED AND REPLACED ALTERNATE STAB TRIM SWITCH PER AMM 27-41-03. OPS CHECK NORMAL.
Part: SENSOR — INOPERATIVE (L ENG) · airframe 101,851 hrs · 26,173 cycles
FLT NO: N/A (MX). ESI - L ENG FAN AIR TEMP SENSOR FAULTY. R/R L ENG FAN AIR TEMP SENSOR PER AMM 36-11-00.
Part: REGULATOR — FAULTY (L ENG PYLON) · airframe 101,813 hrs · 26,148 cycles
FLT NO: MGE 410 (EVENT/ESI) - LEFT BLEED OFF DURING CLIMB (AIR RETURN). REPLACED PRSOV REGULATOR PER AMM 36-11-19. RAN ENGINES OPS CHECK GOOD.
Part: LINE — CRACKED (LH PYLON) · airframe 101,816 hrs · 26,150 cycles
FLT NO: N/A (MX FINDING) - L ENG BLEED INOP. DURING HEALTH CHECK, FOUND PNEUMATIC LEAK DUE TO A CRACKED LINE BETWEEN THE LH PRSOV REGULATOR AND THE LH 450 DEGREE SENSOR. THE LINE WAS REPLACED AND THE LEAK CHECK PASSED HOWEVER THE LH ENG BLEED REMAINED INOP DURING OEPRATIONAL CHECKS.
Part: ACM — SEIZED (LH PACK BAY) · airframe 101,776 hrs · 26,136 cycles
FLT NO. N/A (MX INSP) ESI - LH AIR CYCLE MACHINE INOP. REPLACED AIR CYCLE MACHINE PER AMM 21-51-03.
2022
Part: EEC — FAULTY (L ENG) · airframe 101,231 hrs · 26,002 cycles
FLT NO. N/A (MX INSP). ESI - L ENG TURBINE COOL STATUS MSG. R/R LEFT ENGINE EEC.
Part: SHUTOFF VALVE — FAULTED (LT ENG BLEED) · airframe 101,188 hrs · 25,990 cycles
FLT NO. N/A (MX INSP). ESI - APU BLEED INOP. FOUND LEFT ENGINE BLEED LIGHT NOT ILLUMINATED. R/R LEFT ENGINE PRSOV.
Part: EEC — FAULTED (LT ENGINE) · airframe 101,062 hrs · 25,960 cycles
FLT NO. MGE503. ESI - AUTO THROTTLE DISCONNECT, FOUND LEFT ENG EEC FAULTY. REMOVED AND REPLACED LEFT ENG EEC.
Part: RELAY — FAULTED (APU) · airframe 101,008 hrs · 25,942 cycles
ESI. REMOVED AND REPLACED APU TRU AND APU TRU RELAY DUE TO APU FAULT.
Part: VALVE — FAULTY (L ENG) · airframe 100,368 hrs · 25,777 cycles
L ENG TAIL PIPE FIRE. R/R L ENG SCAVENGE VALVE PER AMM 79-21-12.
Part: SCAVENGE PUMP — FAULTY (L ENG) · airframe 100,368 hrs · 25,777 cycles
L ENG TAIL PIPE FIRE. R/R SCAVENGE PUMP PER AMM 79-21-04.
Part: VALVE — FAULTY (R ENG) · airframe 100,368 hrs · 25,777 cycles
BLEED OFF WHEN ENG ANTI ICE ON. R/R RH ENG ANTI ICE VALVE PER AMM 30-21-03.
Part: APU — FAULTY (APU) · airframe 100,351 hrs · 25,773 cycles
APU LOW PNEUMATIC PRESSURE. R/R APU ASSY. PER AMM 49-11-01.
Part: ECU — FAULTY (AFT CARGO) · airframe 100,300 hrs · 25,761 cycles
APU DUCT PRESSURE LOW. R/R APU ECU PER AMM 49-61-05.
Part: PUMP — LEAKING (L ENG) · airframe 99,980 hrs · 25,681 cycles
FOUND HYD. LEAK AT L ENG EDP... R/R L ENG EDP PER AMM 29-11-05. ENG RUN NORMAL NO LEAKS FOUND.
Part: CONTROL UNIT — FAULTY (L ENG) · airframe 99,980 hrs · 25,681 cycles
L/H ENG FLUCTUATING EPR 1.12-1.19 N1 79.2-81.3 ALONG WITH THE DUCT PRESSURE FROM 25PSI-30PSI. R/R FUEL CONTROL UNIT, LEAK CHECK AND ENGINE RUN GOOD PER AMM 73-21-01.
Part: BLEED VALVE — FAULTY (L ENG) · airframe 99,950 hrs · 25,676 cycles
DURING INITIAL CLIMB AFTER TAKEOFF, LEFT ENGINE EGT WENT TO 661 DEGREES. ENGINE DID NOT STABILIZE DURING CLIMB (AIR RETURN). REMOVED AND REPLACED 14TH STAGE BLEED CONVERTER VALVE PER AMM 75-32-03. PERFORMED ENG RUN PER AMM 71-00-00. OPS CHECK OK, ACFT RETURNED TO SERVICE.
Part: SHUTOFF VALVE — FAULTY (R ENG) · airframe 99,920 hrs · 25,668 cycles
R ENG HPSOV SECURED CLOSED DUE TO EICAS BLEED OFF MSG. R/R R ENG HPSOV PER AMM 36-11-07.
Part: CONVERTER — FAULTY (R ENG) · airframe 99,912 hrs · 25,663 cycles
REF. LP 61779 ITEM 1 RH ENG SURGE DURING CLIMB OUT . EPR SURGE BETWEEN 1.19-1.24. R/R 14TH STAGE BLEED CONVERTER PER AMM 75-32-03.
Part: OUTFLOW VALVE — FAULTY (ZONE 165) · airframe 99,793 hrs · 25,627 cycles
REF. LP 61738 ITEM 1 OUTFLOW VALVE POSITION IND. INOP. R/R OUTFLOW VALVE PER AMM 21-31-04.
Part: SENSE LINE — CLOGGED · airframe 99,816 hrs · 25,635 cycles
EVENT - MGE 880 AIR RETURN DUE TO NO EPR VALUES ON PRIMARY AND STANDBY ON LH ENG. MX PURGED LH ENG SENSE LINES, LH ENG RUN UP. OPS CHECK NORMAL PER FIM 71-01 TABLE 308, AMM 71-00-00.
Part: PROBE — BLOCKED · airframe 99,817 hrs · 25,636 cycles
EVENT - MGE 880 2ND AIR RETURN DUE TO LH ENG NO EPR INDICATIONS ON CLIMB OUT, BOTH PRIMARY AND STANDBY. MX CHECKED EPCS PAGE WITH T2 FAULT MESSAGE . PERFORMED FIM 77-11 F/T 802 FOUND BLOCKAGE AT PT2 PROBE. REMOVED AND RE-INSTALLED PT2 PROBE PER AMM 73-21-03 PG 401. CLEARED BLOCKAGE.
Part: EEC — FAULTY (L ENG) · airframe 99,704 hrs · 25,602 cycles
LEFT ENGINE CONTINUOUS FLUCTUATION DURING CRUISE. REPLACED EEC IAW 73-21-04. PERFORMED ENG RUN. VERIFIED NO EPCS MSG SHOWN.
Part: SLAT — DAMAGED (LE #5) · airframe 99,661 hrs · 25,595 cycles
NO. 5 LEADING EDGE SLAT WAS FOUND DAMAGED ON ARRIVAL. DISCREPANCY IS CURRENTLY OPEN PENDING THE REPLACEMENT OF THE SLAT.
Part: BLEED VALVE — UNSERVICEABLE (L ENG) · airframe 99,285 hrs · 25,496 cycles
DUE TO HISTORY, REMOVED AND REPLACED 14TH STAGE BLEED VALVE ON L ENG WITH AN OVERHAULED UNIT IAW AMM 75-32-02.
Part: TRANSMITTER — UNSERVICEABLE (R ENG) · airframe 99,260 hrs · 25,492 cycles
CREW REPORTED THAT ON TAKE OFF ROLL, RIGHT ENGINE OIL PRESSURE DROPPED FORM 140 PSI TO 95 PSI. REMOVED AND REPLACED MAIN OIL PRESSURE TRANSMITTER IAW AMM 79-32-01 PG 401.
Part: BLEED VALVE — UNSERVICEABLE (L ENG) · airframe 99,203 hrs · 25,475 cycles
CREW REPORTED LEFT ENGINE FLUCTUATES STARTING FL 330 & INTERMITTENTLY DURING CRUISE @ FL 340. EPR .04/ N1 .4. REMOVED AND REPLACED LEFT ENGINE 14TH STAGE BLEED VALVE IAW AMM 73-32-02.
Part: BLEED ACTUATOR — UNSECURE (R ENG) · airframe 99,181 hrs · 25,468 cycles
CREW REPORTED DURING CLIMB OUT, THEY HAD A SLIGHT FLUCTUATION ON THE RIGHT ENGINE EPR OF +/- 0.3. FLUCTUATION STOPPED AFTER THRUST LEVER WAS PULLED BACK. MAINT. TROUBLESHOT PER FIM 73-21 FT 813, REMOVED AND REPLACED RIGHT ENGINE 2.5 INTER-COMPRESSOR BLEED ACTUATOR IAW AMM 75-32-01, NO LEAKS NOTED.
Part: GENERATOR — UNSERVICEABLE (APU) · airframe 99,007 hrs · 25,420 cycles
AIRCRAFT LANDED IN KSA WITH APU GENERATOR INOPERATIVE. UNABLE TO MEL DUE TO NO GROUND POWER UNIT AND NO AIRSTART UNIT AVAILABLE IN KOSRAE. AIRCRAFT AOG, SENT RESCUE FLIGHT WITH PARTS AND TECHNICIAN. REMOVED AND REPLACED APU GENERATOR, OPS CHECK NORMAL.
2021
Part: NONE — UNSERVICEABLE (R ENG) · airframe 98,303 hrs · 25,268 cycles
DISCREPANCY: R BLEED OFF DURING CLIMB AFTER ENG ICE ON. CORRECTIVE ACTION: REMOVED AND REPLACED #2 ENGINE INLET THERMAL ANTI-ICE VALVE AS PER AMM 30-21-03. OPERATIONAL TEST NORMAL.
Part: SHUTOFF VALVE — FAULTY (L ENG) · airframe 98,303 hrs · 25,268 cycles
LEFT ENGINE PRSOV REPLACED DUE TO DIFFICULTY IN MANUALLY OPERATING DURING TROUBLESHOOTING.
Part: SURGE VALVE — UNSERVICEABLE (APU) · airframe 98,115 hrs · 25,227 cycles
RT ENG HUNG START, WAS ONLY ABLE TO GET 19% N2 BEFORE FUELING/SHUTOFF FUEL AT 2:15 SEC. AT 30% N2 PER ABORT START CHECKLIST QRH 7.1 N2 WAS NOT CLIMBING. REPLACED APU SURGE BLEED VALVE REF AMM 49-53-00. PERFORMED ENGINE 1,2 DRY MOTOR RUN OBSERVING APU BLEED PRESSURE-NORMAL. REF 71-00-00 PG. 250.
Part: STARTER — FAULTED (LT ENGINE) · airframe 97,662 hrs · 25,128 cycles
FIRST START ATTEMPT ON LEFT ENG. WS ABORTED FOR STARTER LIMIT (2 MIN.)REMOVED AND REPLACED STARTER, NO LEAKS FOUND. OPS CHECK NORMAL REF. AMM 80-11-01. MEL CLEARED.
Part: START VALVE — FAULTED (LT ENGINE) · airframe 97,566 hrs · 25,108 cycles
STARTER VALVE DID NOT OPEN IN ATTEMPT TO START #1 ENG.
Part: FUEL CONTROL — FLUCTUATES (RT ENGINE) · airframe 97,270 hrs · 25,038 cycles
LOGPAGE 61085 ITEM 1. RIGHT ENGINE SURGE TAKE-OFF CLIMB TO 1500 FEETBETWEEN 1.16 TO 1.21 EPR. REMOVED AND REPLACED RIGHT ENGINE FUEL CONTROL UNIT PER AMM 73-21-02. NO FURTHER ISSUES AFTER REPLACEMENT.
Part: GEARBOX — LEAKING (RT ENGINE) · airframe 97,212 hrs · 25,024 cycles
DURING PREFLIGHT CHECK FOUND HEAVY OIL LEAK COMING FROM #2 ENGINE ORIGINATING FROM ANGLE GEARBOX (ALSO FOUND METAL SHAVINGS). REMOVED AND REPLACE #2 ENGINE MAIN AND ANGLE GEARBOX ASSEMBLY IAW AMM 72-61-01. PERFORMED ENGINE RUN AND LEAK CHECK WITH NO FURTHER LEAKS NOTED.
Part: FMC — FAULTED (LEFT) · airframe 97,182 hrs · 25,016 cycles
LEFT FMC REPLACED DUE TO UNIT FAILING ON POWER UP. AFTER REPLACEMENT FMC CONFIRMED OPERATIONAL.
Part: TRANSCEIVER — FAULTY (E & E BAY) · airframe 96,251 hrs · 24,785 cycles
DISCREPANCY - LEFT HF INOPERATIVE. CORRECTIVE ACTION - REMOVED AND REPLACED LEFT HF TRANSCEIVER IAW AMM 23-11-03. OPS CHECK OK.
Part: STARTER — WORN (APU) · airframe 96,184 hrs · 24,768 cycles
DISCREPANCY - APU WON'T START CORRECTIVE ACTION - REMOVED AND REPLACED APU STARTER MOTOR IAW AMM 49-41-01. OPS CHECK AND LEAK CHECK OK.
Part: ECU — FAULTY (APU) · airframe 96,008 hrs · 24,731 cycles
APU EGT 635. CORRECTIVE ACTION: REMOVED AND REPLACED APU ECU, IAW AMM 49-61-05. OPERATIONS CHECK AND BITE TEST OK. EGT NORMAL.
Part: CHIP DETECTOR — DAMAGED (RT ENGINE) · airframe 98,978 hrs · 24,726 cycles
RT ENGINE MASTER MAGNETIC CHIP DETECTOR HOUSING DAMAGED. CORRECTIVE ACTION: REMOVED AND REPLACED RT ENGINE MCD HOUSING, IAW AMM 79-21-10. LEAK CHECK OK.
Part: MONITOR — FAULTY (ENG VIBRATION) · airframe 95,952 hrs · 24,715 cycles
ENGINE VIB INDICATION INTERMITTENT. ON AND OFF DURING FLIGHT. CORRECTIVE ACTION: FOUND AVM IS BAD FROM STOCK. REMOVED AND REPLACED AIRBORNE VIBRATION MONITOR SIGNAL CONDITIONER, IAW AMM 77-31-02. OPERATIONS CHECK OK.
Part: ECU — INOPERATIVE (APU) · airframe 95,932 hrs · 24,711 cycles
APU WON'T START AFTER LANDING. REMOVED AND REPLACED APU ECU, IAW AMM 49-61-05. PERFORMED OPERATIONS CHECK, IAW AMM 49-11-00 SATISFACTORY.
Part: SIGNAL COND UNIT — FAULTED (ENGINE VIBRATION) · airframe 95,907 hrs · 24,704 cycles
DISCREPANCY MAINTENANCE MESSAGE "ENGINE VIB BITE". CORRECTIVE ACTION: REMOVED AND REPLACED AVM SIGNAL CONDITIONER, IAW AMM 77-31-00. TEST OK.
2020
Part: WARNING MESSAGE — FALSE ACTIVATION (RT OIL FILTER) · airframe 95,690 hrs · 24,694 cycles
DISCREPANCY-STATUS MESSAGE "RT OIL FILTER" AFTER START RETURN TO GATE. CORRECTIVE ACTION: REMOVED AND REPLACED RT ENGINE MAIN OIL FILTER, IAW AMM 79-21-05. NO METAL OR DEBRIS ON FILTER AND MCD NOTED. RAN ENGINE LEAK CHECK AND OPERATIONS CHECK OK.
Part: IGNITION UNIT — FAILED (APU) · airframe 95,742 hrs · 24,669 cycles
DISCREPANCY-APU WOULD NOT START ON ARRIVAL. CORRECTIVE ACTION: REMOVED AND REPLACED APU IGNITION UNIT, IAW AMM 49-41-03. OPERATIONS CHECK OK.
Part: B-NUT — LEAKING (IDG) · airframe 95,446 hrs · 24,597 cycles
DISCREPANCY: "RT GEN DRIVE" EICAS MESSAGE (AIR RETURN). CORRECTIVE ACTION: FOUND "RT IDG LOW OIL PRESS" ON BPCU. EXAMINED DPI, NOT EXTENDED. RE-CONNECTED IDG AND PERFORMED IDG OIL SERVICING, PER AMM 12-13-03, AND FOUND OIL LEAK FROM B-NUTS ON IDG. TIGHTENED B-NUTS AND RAN ENGINE AND OPERATIONS CHECK OK, IAW AMM 24-11-00.
Part: START VALVE — FAULTY (RIGHT ENGINE) · airframe 95,437 hrs · 24,602 cycles
DISCREPANCY: RT ENGINE STARTER CUTOUT "VALVE" LIGHT STAYED. CORRECTIVE ACTION: REMOVED AND REPLACED RT ENGINE STARTER VALVE, IAW AMM 80-11-02. LEAK CHECK AND OPERATIONS CHECK OK.
Part: FILTER — UNSERVICEABLE (RIGHT ENGINE) · airframe 95,303 hrs · 24,568 cycles
"RT OIL FILTER" STATUS MESSAGE. INSPECTED MAG CHIP DETECTORS, IAW AMM 79-21-10. NO DEFECTS NOTED. REMOVED AND REPLACED RIGHT ENGINE MAIN OIL FILTER, IAW AMM 79-21-05. RAN RIGHT ENGINE NO LEAK NOTED.
Part: CONTROLLER — FAULTED (COCKPIT TEMP) · airframe 95,303 hrs · 24,568 cycles
"FLIGHT DECK ZONE TRIM AIR MODULATING VALVE INOPERABLE". REMOVED AND REPLACED ZONE TEMP CONTROLLER, IAW AMM 21-61-03.
Part: SEAL — WORN (STARTER DRIVE) · airframe 95,230 hrs · 24,550 cycles
RIGHT ENGINE OIL CONSUMPTION ABOVE NORMAL. REMOVED AND REPLACED RIGHT ACCESSORY GEAR BOX STARTER DRIVE SEAL, IAW AMM 72-61-02. RAN RIGHT ENGINE NO LEAK NOTED.
Part: CONTROLLER — DEFECTIVE (WINDOW HEAT) · airframe 94,909 hrs · 24,468 cycles
SMOKE REPORTED IN THE COCKPIT COMING FROM F/O R1 WINDSHIELD AREA. FLIGHT DIVERTED DUE TO DECLARED EMERGENCY. MX FOUND FAULTY WINDOW HEAT CONTROLLER. REPLACED DEFECTIVE WINDOW HEAT CONTROLLER AND R1 WINDOW.
Part: PRESSURE SWITCH — MALFUNCTIONED (HYD SYSTEM) · airframe 94,606 hrs · 24,384 cycles
"C HYD SYS PRESS" EICAS MSG APPEARED IN FLIGHT. THE FLIGHT CREW VERIFIED NO OTHER ABNORMALITIES WERE ASSOCIATED WITH THE SYSTEM. AFTER FOLLOWING QRH PROCEDURES, THE FLIGHT CREW DECLARED AN EMERGENCY AS PRECAUTION ALTHOUGH NO EMERGENCY ACTION WAS REQUIRED PER THE QRH PROCEURES. NO SYSTEM DEFECTS WERE NOTED DURING THE OPERATIONAL CHECKS BY MX. THE CENTER HYD PRESSURE SWITCH WAS REPLACED AS A PRECAUTION.
Part: PILOT VALVE — DEFECTIVE (LT ENGINE) · airframe 94,562 hrs · 24,372 cycles
LH ENG HP PILOT WAS REPLACED DUE TO LOW BLEED PRESSURE AT IDLE POWER
Part: ECU — FAULTY (APU) · airframe 94,006 hrs · 24,187 cycles
AIRCAFT ARRIVED IN HNL WITH APU UNABLE TO START ON DURING TAXI INTO THE GATE. APU ECU WAS CONFIRMED FAULTY AFTER PERFORMING OPERATIONAL CHECKS. ECU WAS REPLACED AND APU STARTED WITHOUT ANY FURTHER ISSUES.
Part: TRANSMITTER — OUT OF TOLERANCE (NR 2 FUEL FLOW)
"FUEL DISAGREE PROG 2". FUEL FLOW DISAGREE BY 600#'S TOTALIZE FUEL ONLY INTO FLIGHT. RIGHT HIGHER THAN LEFT. REMOVED AND REPLACED #2 ENGINE FUEL FLOW TRANSMITTER I.A.W. AMM 73-31-01 AND PERFORMED ENGINE RUN AND LEAK CHECK. LECH CHECK GOOD, FUEL FLOW NOW AT 1.1 VERSUS 1.6. AIRCRAFT BACK IN SERVICE.
Part: FIRE LOOP — SHORTED (RT ENGINE) · airframe 93,880 hrs · 24,165 cycles
RH ENG FIRE LOOP DETECTOR NO 2 MSG APPEARED IN FLIGHT. ITEM WAS PLACED ON MEL. PART WAS THEN REPLACED WITHOUT FURTHER DEFECTS
Part: FIRE LOOP — SHORTED (RT ENGINE) · airframe 93,871 hrs · 24,159 cycles
RH ENG FIRE LOOP DETECTOR NO 2 WAS FOUND FAULTY DURING A PRE FLIGHT CHECK. PART WAS REPLACED WITHOUT ANY FURTHER DEFECTS