N692NK

AIRBUS A320-232 · 2018 · Fixed-wing multi-engine · 2 engines · 200 seats · Valid Registration

Registered owner: SPIRIT AIRLINES LLC, FL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

47 reports on file, 2019-02-18 – 2024-11-08.

NO TEST · 2024-11-08 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (ZONE 800 ASSIST) · airframe 19,249 hrs · 8,838 cycles

L1 & R2 DOOR ASSIT BOTTLE REQUIRE SERVICE-SERVICE L1 & R2 DOOR ASSIT BOTTLE IAW AMM 52-10-00 TO PROPER LEVEL

Source: SDR GTIA2024110838512
SMOKE/FUMES/ODORS/SPARKS · 2024-10-26 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (FWD GALLEY) · airframe 19,163 hrs · 8,800 cycles

SMOKE / BURNING SMELL COMING FROM FWD GALLEY / FAP PANEL -PER MOC PERFOERED GVI OF WIFI R&R RECP FILTERS , EPSU, COFFEE MAKERS, LAV WATER HEATER SEE L/P 3604613-2 THRU 360418-2 IAW TSM 05-50-00 PERFORMED ENG RUN WITH PACKS ON AND OFF IAW AMM 71-00-00 NO ODOR DETECTED.

Source: SDR GTIA2024102838491
SMOKE/FUMES/ODORS/SPARKS · 2024-10-25 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 19,162 hrs · 8,799 cycles

FLIGHT ATTENDANT REPORT OF ELECTRICAL BURNING SMELL BETWEEN ROWS 7ABC-11ABC-PERFORMED INSPECTION IAW TSM 05-50-00 NO DEFECTS NOTED UNABLE TO DUPLICATE AT THIS TIME A/C OK FOR CONTINUED SERVICE

Source: SDR GTIA2024102838487
OTHER · 2024-10-11 Matched by certificate designator
ATA 2530

Part: DECK PLATE — DAMAGED (G4 GALLEY) · airframe 19,029 hrs · 8,727 cycles

"GALLEY G4 WORKDECK RAF 01-3337210-2 GENERATED -GALLEY G4 WORKDECK REPLACED IAW EC 2533-015"

Source: SDR GTIA2024101238439
OTHER · 2024-08-04 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (DOOR ASSIST) · airframe 18,715 hrs · 8,558 cycles

DURING SERVICE CHECK, FOUND L1 AND R2 DOOR ASSIST BOTTLES LOW-SERVICED L1 AND R2 DOOR ASSIST BOTTLES IAW AMM 52-10-00.

Source: SDR GTIA2024080538273
OTHER · 2024-07-08 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 18,430 hrs · 8,418 cycles

R2 DOOR ASSIST BOTTLE REQ SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2024070938221
OTHER · 2024-04-21 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 17,636 hrs · 8,021 cycles

R2 DOOR ASSIST BOTTLE LOW.-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2024042338077
SMOKE/FUMES/ODORS/SPARKS · 2024-03-09 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 17,292 hrs · 7,873 cycles

SUSPECTED FUME EVENT ON APPROACH TO MCO AT APPROX 5000FLT FA REPORTS DIRTY SOCK SMELL ALSO NOTICED BY REST OF CREW.SMELL REMAINED NOTICEABLE DURING TAXI UNTIL ENG 2 SHUTDOWN.2 PAX/FA SICK-PERFORMED AIR QUALITY EVENT IN REF TO TI 2100-2002-CEO ALSO PERFORMED DECONTAMINATION OF THE ECS IAW AMM 21-00-00-615-802-A NO FINDINGS OR ODORS NOTED AT THIS TIME. A/C OK FOR SERVICE. R&R BOTH PACK 1&2 RECIRCULATION FILTERS IAW AMM 21-21-41

Source: SDR GTIA2024031237980
SMOKE/FUMES/ODORS/SPARKS · 2024-03-09 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 1) · airframe 17,296 hrs · 7,875 cycles

BELOW 10,000 GOT DIRTY SOCK SMELL REPORTED BY THE FA. AFTER TAKEOFF RAN ELIMINATION OF ODER QRH- ODOR WENT AWAY, PACK 1 OFF, X BLEED SHUT-PERFORMED PACK BURNOUT IAW AMM 21-00-00. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. A/C GOOD FOR SVC.

Source: SDR GTIA2024031237981
Earlier reports · 2019–2023 · 38 reports

2023

OTHER · 2023-10-26 Matched by certificate designator
ATA 3830

Part: LAVATORY — INOPERATIVE · airframe 16,007 hrs · 7,276 cycles

ALL LAVS WILL NOT FLUSH ALL ALTITUDES-REMOVED AND INSTALLED LIQUID LEVEL TRANSMITTER TO WASTE TANK IAW AMM 38-32-00. LEAK CHECK GOOD. PERFORMED LAVS OPS CHECK IAW AMM OPS CHECK GOOD AC GOOD FOR SVC.

Source: SDR GTIA2023102737564
OTHER · 2023-08-08 Matched by certificate designator
ATA 3240

Part: MANIFOLD — OVERTEMP (BRAKES) · airframe 15,200 hrs · 6,928 cycles

BRAKES HOT # 2 REACHED 980C 3&4 WERE OVER 500C FELT AS IF BRAKES WERE RUBBING-R + R ALTERNATE BRAKE MANIFOLD (2853GM) IAW AMM 32-43-32. OPS TEST AND LEAK TEST GOOD

Source: SDR GTIA2023081037401
OTHER · 2023-07-10 Matched by certificate designator
ATA 5210

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 14,928 hrs · 6,791 cycles

R2 PASSENGER DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED R2 PASSENGER DOOR IAW AMM 52-10-00

Source: SDR GTIA2023071037322
OTHER · 2023-03-26 Matched by certificate designator
ATA 5200

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 13,855 hrs · 6,308 cycles

L1 DOOR ASSIST ACCUMULATOR @ 1400-SERVICED L1 DOOR ASSIST ACCUM. REF. AMM 52-11-14

Source: SDR GTIA2023032737076
OTHER · 2023-03-26 Matched by certificate designator
ATA 5210

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 13,855 hrs · 6,308 cycles

DOOR ASSIST ACCUMULATOR @ R2 @ 400PSI-SERVICED R2 DOOR ASSIST ACCUM. REF. AMM 52-11-14

Source: SDR GTIA2023032737075
OTHER · 2023-03-23 Matched by certificate designator
ATA 2120

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 13,854 hrs · 6,307 cycles

DURING TAKEOFF UNABLE TO BRING UP GEAR. THEN GOT VENT EXTRACT FAULT. NO LANDING GEAR ECAM INDICATION.--

Source: SDR GTIA2023032337066

2022

OTHER · 2022-12-17 Matched by certificate designator
ATA 3350

Part: FLASHLIGHT — INOPERATIVE (ZONE 900) · airframe 12,981 hrs · 5,870 cycles

FWD RH CABIN FLASHLIGHT INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R FLASHLIGHT ASSY IAW AMM 25-65-00. THIS CLEARS MDDR 44395. PLACARD REMOVED. MOC NOTIFIED.

Source: SDR GTIA2022121936838
OTHER · 2022-09-18 Matched by certificate designator
ATA 5210

Part: NONE — NONE · airframe 12,094 hrs · 5,488 cycles

R2 DOOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2022091936671
OTHER · 2022-09-16 Matched by certificate designator
ATA 3800

Part: LAVATORY — INOPERATIVE (ZONE 900) · airframe 12,076 hrs · 5,481 cycles

DIVERTED TO DEN BECAUSE ALL LAVS INOP IN FLIGHT-PERFORMED OPS TEST OF THE WASTE WATER DRAIN SYS PER AMM 38-32-00-710-002-A OPS CHECK GOOD AT THIS TIME NO FURTHER DEFECTS NOTED ALL LAVS NOW OPERATE AS DESIGNED ACFT OK FOR SERVICE

Source: SDR GTIA2022091936669
OTHER · 2022-08-12 Matched by certificate designator
ATA 5210

Part: NONE — NONE · airframe 11,729 hrs · 5,327 cycles

DURING WEEKLY CHECK FOUND R2 DOOR ASSIST REQ SERVICE-SERVICED R2 DOOR ASSIST IAW AMM 52-10-00

Source: SDR GTIA2022081536583
OTHER · 2022-03-28 Matched by certificate designator
ATA 5210

Part: NONE — NONE · airframe 10,468 hrs · 4,752 cycles

L1 AND R2 ENTRY DOORS ASSIST BOTTLE REQUIRE SERVICING-SERVICED L1 AND R2 ENTRY DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2022032836353
OTHER · 2022-03-27 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE · airframe 10,465 hrs · 4,750 cycles

FWD FAS FLASHLIGHT INOP-R&R FWD F/AS FLASHLIGHT IAW CMM 25-60-02. OPS CK GOOD

Source: SDR GTIA2022032836349
OTHER · 2022-01-30 Matched by certificate designator
ATA 5210

Part: NOT REPORTED — NOT REPORTED · airframe 9,922 hrs · 4,535 cycles

DURING WEEKLY FOUND L1 AND R2 DOOR ASSIST PRESSURE REQ SERVICE-SERVICED L1 AND R2 DOOR ASSIST IAW 52-10-00.

Source: SDR GTIA2022013136251
OTHER · 2022-01-14 Matched by certificate designator
ATA 5210

Part: NOT REPORTED — NOT REPORTED · airframe 9,748 hrs · 4,467 cycles

L1 DOOR ASSIST BOTTLE AND R4 DOOR ASSIST BOTTLE REQUIRES SERVICING. -SERVICED L1 DOOR ASSIST BOTTLE AND R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.

Source: SDR GTIA2022011736221

2021

OTHER · 2021-10-18 Matched by certificate designator
ATA 3441

Part: NONE — INOPERATIVE · airframe 9,035 hrs · 4,159 cycles

WX RADAR INOP.-R&R TRU (13SQ1) OPS CHECK OK REF AMM 34-41-51

Source: SDR GTIA2021102136059
OTHER · 2021-09-16 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 8,726 hrs · 4,026 cycles

PER WEEKLY FOUND L1 AND R2 DOOR EMER ASSIST BOTTLE REQ SERVICE -SERVICE L1 AND R2 DOOR EMER ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2021091635989
OTHER · 2021-08-25 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 8,547 hrs · 3,936 cycles

R2 DOOR ASIST ACCUMULATER REQUIRES SERVICE-SERVICED R2 DOOR ASIST BOTTLE IAW AMM 52-10-02

Source: SDR GTIA2021082635947
OTHER · 2021-06-23 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R4 DOOR ASSIST) · airframe 8,004 hrs · 3,670 cycles

R4 DOOR ASSIST BOTTLE REQUIRES SERVICING.-SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK + OPS TEST OK.

Source: SDR GTIA2021062135821
OTHER · 2021-06-09 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 7,879 hrs · 3,607 cycles

"R2 DOOR REQ SERVICE ON DOOR ASSIT -SERVICED R2 DOOR IAW AMM 52-10-00.

Source: SDR GTIA2021061035795
OTHER · 2021-06-09 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 7,879 hrs · 3,607 cycles

"L 1 DOOR REQ SERVICE ON DOOR ASSIT -SERVICED L1 DOOR IAW AMM 52-10-00.

Source: SDR GTIA2021061035794
OTHER · 2021-03-31 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 7,251 hrs · 3,307 cycles

R2 DOOR ASSIST BOTTLE LOW.-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001

Source: SDR GTIA2021040135666
OTHER · 2021-03-11 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 7,057 hrs · 3,223 cycles

R2 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2021031235636
OTHER · 2021-03-04 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 7,006 hrs · 3,200 cycles

R2 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.

Source: SDR GTIA2021030435623
OTHER · 2021-01-29 Matched by certificate designator
ATA 5210

Part: BOTTLE — LOW PRESSURE (L2 DOOR ASSIST) · airframe 6,775 hrs · 3,101 cycles

DURING WEEKLY CHECK FOUND L2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR IAW AMM 52-10-00 LEAK CHECK GOOD.

Source: SDR GTIA2021020135577

2020

OTHER · 2020-11-27 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (DOOR ASSIST) · airframe 6,252 hrs · 2,861 cycles

RT AFT DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED RT AFT DOOR ASSIST BOTTLE, IAW AMM 52-10-00.

Source: SDR GTIA2020113035477
OTHER · 2020-11-20 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 6,170 hrs · 2,820 cycles

R2 DOOR ASSIST BOTTLE PRESS IS LOW. SERVICE R2 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.

Source: SDR GTIA2020112335462
OTHER · 2020-02-29 Matched by certificate designator
ATA 5210

Part: BOTTLE — LOW PRESSURE (R2 DOOR) · airframe 4,823 hrs · 2,189 cycles

R2 DOOR ASSIST BOTTLE LOW-SVC R2 DOOR ASSIST BOTTLE TO PROPER LVL IAW AMM 52-10-00. LEAK CHK GOOD

Source: SDR GTIA2020030235060
SMOKE/FUMES/ODORS/SPARKS · 2020-01-17 Matched by certificate designator
ATA 2150

Part: A/C PACK — FUMES (NR 1) · airframe 4,375 hrs · 1,980 cycles

FUME EVENT ON APPROACH TO LANDING. PERFORMED T/S IAW TSM 05-50-00, ISOLATED PACK 1.

Source: SDR GTIA2020012034951
OTHER · 2020-01-14 Matched by certificate designator
ATA 5210

Part: BOTTLE — LOW PRESSURE (R2 DOOR) · airframe 4,348 hrs · 1,970 cycles

PASSENGER/ CREW DOOR R2 DOOR ASSIT BOTTLE NEEDS SERVICING. SERVICED THE PASSENGER / CREW DOOR R2 DOOR ASSIT BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.

Source: SDR GTIA2020011634946

2019

WARNING INDICATION · 2019-12-02 Matched by certificate designator
ATA 3234

Part: LEVER — MALFUNCTIONED (MLG) · airframe 3,933 hrs · 1,786 cycles

LGCIU 1 + 2 FAULT-R/R LANDNG GEAR LEVER IAW AMM 32-31-11. OPS CHECK GOOD

Source: SDR GTIA2019120524830
SMOKE/FUMES/ODORS/SPARKS · 2019-08-28 Matched by certificate designator
ATA 2120

Part: SEAT — ODOR (4C) · airframe 2,885 hrs · 1,306 cycles

PAX REPORT EXTREMELY OFFENSIVE ODOR COMING FROM DEFERRED SEAT 4C. ( PASSENGER SEAT(S) PASSENGER SEAT(S) )--

Source: SDR GTIA2019083084581
OTHER · 2019-08-10 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 2,654 hrs · 1,212 cycles

R2 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2019081204548
OTHER · 2019-08-03 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR) · airframe 2,572 hrs · 1,174 cycles

R2 DOOR ASSIST ACCUMULATOR LOW-SERVICED R2 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00

Source: SDR GTIA2019080334531
OTHER · 2019-07-31 Matched by certificate designator
ATA 5210

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 2,560 hrs · 1,168 cycles

R2 DOOR ASSIST BOTTLE AT 250 PSI. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-10-00.

Source: SDR GTIA2019080134519
OTHER · 2019-05-29 Matched by certificate designator
ATA 5210

Part: ASSIST ASSY — LOW PRESSURE (R2 DOOR) · airframe 1,843 hrs · 848 cycles

R2 DOOR ASSIST REQUIRES SERVICING. SERVICED R2 DOOR ASSIST IAW AMM 52-10-00. LEAK CHECK GOOD.

Source: SDR GTIA2019052903375
OTHER · 2019-05-08 Matched by certificate designator
ATA 5220

Part: BOTTLE — LOW PRESSURE (R2 DOOR) · airframe 1,604 hrs · 735 cycles

R2 DOOR ASSIST BOTTLE NEED SERVICE. SERVICED TO PROPER LEVEL R2 DOOR ASSIST BOTTLE IAW AMM 52-22-00.

Source: SDR GTIA2019050803334
OTHER · 2019-04-05 Matched by certificate designator
ATA 2560

Part: BOTTLE — LOW PRESSURE (R2 DOOR ASSIST) · airframe 1,245 hrs · 568 cycles

R2 DOOR ASSIST BOTTLE LOW-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00

Source: SDR GTIA2019040853271
SMOKE/FUMES/ODORS/SPARKS · 2019-02-18 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 2) · airframe 742 hrs · 329 cycles

CLIMBING OUT OF IAH. FA REPORTED AIR QUALITY EVENT IN AFT CABIN-FOLLOWED TSM 05-50-00 FOR CAUSE OF ODOR OR SMOKE, CHECKED ENGINES + APU FOR SIGNS OF LEAKAGES REF TSM 71-00-00 + 49-00-00 NONE NOTED. ENIGINES RAN BY FLT CREW ISOLATING BLEEDS WHILE OPERATING BOTH PACKS INDIVIDUALLY, FOUND PACK 2 AS CAUSE OF ODOR SEE LP 2403850-2 FPR MEL EMP#48427

Source: SDR GTIA2019022183167