N701QS

BOMBARDIER INC BD-100-1A10 · 2019 · Fixed-wing multi-engine · 2 engines · 8 seats · Valid Registration

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
NetJets Aviation, Inc. (DXTA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

14 reports on file, 2006-11-18 – 2026-05-22.

FLAME/FIRE; VIBRATION/BUFFET; WARNING INDICATION · 2026-05-22 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (LEFT) · airframe 8,074 hrs · 4,738 cycles

ON CLIMBOUT SHORTLY AFTER TAKEOFF, RECEIVED A STRONG VIBRATION FOLLOWED BY A L ENG EXCEEDANCE CAS & A OVERTEMP ON ITT. REDUCED THUST LEVER TO BRING ITT DOWN. RECEIVED A LT ENG VIBRATION CAS FOLLOWED BY A LT ENG FLAMEOUT CASS. VIBRATION DECREASED BUT NEVER WENT AWAY. REMOVED UNSERVICEABLE LT ENGINE, IAW AMM 71-00-01-000-801. INSTALL CUSTOMER PROVIDED REPAIRED ENGINE INSTALLED ON REPLACEMENT LT ENGINE. ALL POST OPS CHECK COMPLETED OPS CHKD GOOD.

Source: SDR DXTA2026052608193
Earlier reports · 2006–2023 · 13 reports

2023

SMOKE/FUMES/ODORS/SPARKS · 2023-12-19 Matched by certificate designator
ATA 2150

Part: ACM — FAULTED (UNKNOWN) · airframe 5,112 hrs · 2,984 cycles

CABIN ODOR IN CABIN. "SOCKS OR WET DOG" SMELL. SEEMS MORE PRONOUNCED AT SEA LEVEL, DENSE AIR. TRANSFERRING TO APU SEEMS TO INCREASE THE SMELL BUT IT MAY JUST BE THE HIGHER FLOW OF AIR. REMOVED AND REPLACED ACM DUE TO TORQUE CHECKS FAIL . OPS/LEAK CHECKS REQUIRED. ACM OPS/LEAK CHECKED GOOD. ALL MX COMPLETED IAW AMM CHAPTER 21-52-13.

Source: SDR DXTA2023122010381

2022

WARNING INDICATION · 2022-05-26 Matched by certificate designator
ATA 7930

Part: NONE — NONE · airframe 3,292 hrs · 1,892 cycles

RIGHT AND LEFT ENGINES - ENGINE OIL PRESSURE: DURING CRUISE AT FL370 THE RIGHT ENGINE OIL PRESS LOW CAS MESSAGE ILLUMINATED ALOMG WITH RED LOW OIL PRESSURE.//CORRECTIVE ACTION//FOUND OIL CAP NOT SECURED, SECURED CAP. PERFORMRMED ENGINE RUNS WITH NO FURTHER LEAKS OR DEFECTS NOTED

Source: SDR DXTA2022052662760

2014

VIBRATION/BUFFET; FLT CONT AFFECTED · 2014-04-02 Matched by certificate designator
ATA 2720

Part: RUDDER — MALFUNCTIONED · airframe 6,024 hrs · 3,791 cycles

AT FLIGHT LEVEL 210 AND AT 345 KNOTS, THE ACFT HAD A BUZZING SOUND & AIRFRAME VIBRATION FELT IN CONTROLS. SHORTLY AFTER HAD A VIOLENT UNCOMMANDED RUDDER LEFT WITH NO PILOT INPUT. THE ACFT JERKED HARD FOR A FEW SECONDS. PERFORMED A NORMAL LANDING. PERFORMED THOROUGH BORESCOPE INSPECTION OF NR 1 & 2 ENGINES WITH NO SIGNIFICANT FINDINGS. PERFORMED FIVE POINT ENGINE CALIBRATION RUNS OF BOTH ENGINES WITH ALL PARAMETERS TO BE WITHIN LIMITS. PERFORMED OPS CHECK OF RUDDER BIAS SYSTEM WITH NO DEFECTS NOTED. INSTALLED P2.8 MOISTURE TRAP AND P2.8 TRANSDUCER LINE WITH NO DEFECTS NOTED. SWAPPED P3 TRANSDUCERS FOR FURTHER OBSERVATION. ALL WORK PERFORMED IAW EMM 75-30-03, 753009, 72-00-00 & AMM 27-20-35.

Source: SDR DXTA2014040405716

2013

WARNING INDICATION · 2013-03-29 Matched by certificate designator
ATA 2730

Part: ACTUATOR — MALFUNCTIONED (ELEVATOR FEEL) · airframe 5,130 hrs · 3,228 cycles

ELEVATOR FEEL FAIL ILLUMINATED TWO TIMES DURING FLIGHT. REMAINING ON FOR 30-60 SECONDS EACH TIME. R & R Q FEEL SERVO ACTUATOR IAW CMP 273014. PERFORMED STALL PROTECTION AND Q FEEL ACTUATOR ADJUSTMENT TEST IAW CMP 273030. NO DEFECTS NOTED.

Source: SDR DXTA201304015344

2012

SMOKE/FUMES/ODORS/SPARKS · 2012-08-24 Matched by certificate designator
ATA 3030

Part: PROBE — OVERHEATED · airframe 4,666 hrs · 2,968 cycles

HEAVY SULFUR ODOR IN COCKPIT WITH APU OPERATING WITH AVIONICS ON. ODOR IS NOT ASSOCIATED WITH ENVIRONMENTAL SYS. NO VISIBILE SMOKE WAS NOTICED. FOUND "PROBE HEAT" SWITCH IN OVERRIDE POSITION. THIS SETTING DELIVERS FULL POWER TO ALL PROBES AND TAKES THE AOA'S FROM LOW TO FULL POWER. OVERHEATING OF THE PROBES WAS CAUSING THE ODOR. INSPECTED PROBES AND FOUND NO DEFECTS. PLACED SWITCH IN AUTO POSITION, ODOR DID NOT RETURN. WORK DONE IAW AMM CH - 30-30-00.

Source: SDR DXTA2012082405105

2011

WARNING INDICATION · 2011-10-25 Matched by certificate designator
ATA 3610

Part: WARNING MESSAGE — ILLUMINATED (BLEED PRESSURE) · airframe 3,864 hrs · 2,467 cycles

BLEED PRESSURE AND TEMP HIGH WARNING MESSAGE ILLUMINATED ON TAKEOFF ROLL. PERFORMED ENGINE RUNS FOR OPS CHECK, WITH ECS SYS ON APU, RAN LT ENGINE & RT ENGINE NOTING NO MESSAGES, INSPECTED PRECOOLERS FOR DAMAGE AND BLOCKAGE NOTING NO FAULTS, INSPECTED PRECOOLER BY PASS VALVE INDICATOR WITH NO FAULTS NOTED. INSPECTED PRECOOLER TEMP SENSOR NOTING NO FAULTS, REF MM 21.00-00.

Source: SDR DXTA2011102504762

2010

FLAME/FIRE; SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 2010-07-16 Matched by certificate designator
ATA 7250

Part: TURBINE BLADES — CRACKED (ENGINE) · airframe 3,181 hrs · 1,981 cycles

ABOUT 45 MINUTES INTO THE FLIGHT, CLIMBING THRU FL 360, CREW HEARD A LOUD "BANG", FELT A VIBRATION, ITT BEGAN AN IMMEDIATE CLIMB, FOLLOWED BY THE "FIRE" LIGHT AND SMOKE IN THE CABIN. CREW BROUGHT THE THROTTLE TO IDLE, SHUT THE ENGINE DOWN VIA THE FUEL CUTOFF SWITCH, DECLARED AN EMERGENCY AND WAS VECTORED BY ATC TO THE NEAREST SUITABLE AIRPORT.

Source: SDR DXTA2010071604156
SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 2010-07-16 Matched by certificate designator
ATA 7200

Part: ENGINE — OVERTEMP (RIGHT) · airframe 3,181 hrs · 1,981 cycles

RT ENGINE SHUTDOWN INFLIGHT DUE TO VIBRATION DETECTOR AT MAX LEVEL WITH CORRESPONDING RISING HIGH ITT LEVEL (NOT IN RED) AND ENGINE FIRE CAS MESSAGE. THERE WAS ALSO THE SMELL OF SMOKE IN THE CABIN BUT NOT VISIBLE. ENGINE WAS SECURED BY POWER TO IDLE AND FUEL CUTOFF SWITCH. THE ENGINE DID NOT AUTO SHUTDOWN. R & R RT ENGINE WITH RENTAL UNIT. PERFORMED OPS CHECKS AND LEAK CHECKS WITH NO DEFECTS NOTED, REF MM 71-00-00.

Source: SDR DXTA201007160415
OVER TEMP; WARNING INDICATION · 2010-03-15 Matched by certificate designator
ATA 2432

Part: BATTERY — OVERHEATED · airframe 2,870 hrs · 1,782 cycles

EMERGENCY BATTERY OVERHEATED IN FLIGHT; TEMP WENT TO 170 DEGREES F, VOLTS REMAINED AT 26.7. R & R EMERGENCY BATTERY WITH O/H UNIT MM 24-30-20, CMP 243019. OPS CHECKS GOOD.

Source: SDR DXTA2010031604036

2008

OTHER · 2008-07-14 Matched by certificate designator
ATA 3414

Part: INDICATOR — INOPERATIVE (AIRSPEED)

NO AIRSPEED ON TAKEOFF ROLL, ABORTED T/O. VISUALLY INSPECTED PITOT TUBES AND LINES. PERFORMED RECONNECT CHECK ON PILOT COPILOT & STANDBY PITOT/STATIC SYSTEM'S REF MM 34-11-00 PGS 602-606 SYSTEM OPS CHECK GOOD AND LEAK CHECK GOOD.

Source: SDR DXTA200803172

2007

OTHER · 2007-11-17 Matched by certificate designator
ATA 5730

Part: SKIN — DAMAGED (RT WING) · airframe 1,086 hrs · 712 cycles

DURING LANDING AND AFTER TOUCHDOWN, THE AIRCRAFT DEPARTED THE LT SIDE OF THE RUNWAY. DAMAGE NOTED ON THE LOWER IB SECTION OF THE RT WING, DAMAGE NOTED ON THE RT WING IB LEADING EDGE, AND DAMAGE NOTED ON THE RT KRUEGER FLAP.

Source: SDR DXTA200702614
SMOKE/FUMES/ODORS/SPARKS · 2007-04-24 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 527 hrs · 322 cycles

ACRID ELECTRICAL BURNING SMELL EMINATING FROM BEHIND LT PILOT SEAT IN COCKPIT. CHECKED ALL CB'S, NOTHING FOUND (POPPED). [4-27-07] PERFORMED ENG RUN AND APCS RUNS FOR COCKPIT SMELLS, RUNS SATISFACTORY. ACCESSED L/R RELAY PANEL FOUND SATISFACTORY. ACCESSED FWD EQUIPMENT CLOSET CB CHR105& CHR203 POPPED. RESEAT OPS CK 115AC OUTLET GOOD. .RE-RACK AIRSHOW COMPUTER. OPS CK GOOD. ACCESSED L/H PILOT WINDSHIELD HEAT T/B. AT OVERHEAD FOUND SATISFACTORY. OPS CHECK DOOR MOTOR GOOD. COULD NOT DUPLICATE BURNING ODOR FOUND AIRCRAFT SATISFACTORY FOR FLIGHT WORK DONE IAW G2000 M/M CH 5-00-00 AND CH 24-00-00.

Source: SDR DXTA200702137

2006

FALSE WARNING · 2006-11-18 Matched by certificate designator
ATA 2612

Part: FIRE LOOP — SHORTED (APU BAY) · airframe 69 hrs · 37 cycles

WE WERE LEVEL AT FLIGHT LEVEL 350 WHEN THE (APU FIRE LIGHT) AND BELL CAME ON. WE FIRED THE BOTTLE AND THE FIRE LIGHT STAYED ON. REMOVED AND REPLACED RT FIRE BOTTLE IAW MM 26-20-05. FIRE LOOP FOUND BAD AND REPLACED. APU FIRE DETECTION SYSTEM WAS OPS CHECKED AND CHECKED GOOD.

Source: SDR DXTA200601734