N706FR
Registered owner: BANK OF UTAH TRUSTEE, UT (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
13 reports on file, 2017-06-12 – 2026-09-03.
Part: WIRE HARNESS — LOOSE (ZONE 800) · airframe 33,835 hrs · 14,778 cycles
DURING HEAVY CHECKED, EPSU (13WL) AFT L/DEU-B (300RH7) FAULT DURING EPSU TEST. ACFT WAS NOT GROUNDED. FOUND ELECTRICAL HARNESS ON R4 DOOR ESCAPE SLIDE UNPLUGGED. PLUGGED HARNESS BACK IN IAW AMM 25-62-44-400-803-A. NO FURTHER DEFECTS NOTED". AIRCRAFT WAS RETURNED TO SERVICE. /END/
Earlier reports · 2017–2025 · 12 reports
2025
Part: BATTERY — FAILED (ZONE 200) · airframe 31,358 hrs · 13,575 cycles
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING OPC FOUND EPSU BATTERY 15WL INOP REPLACEMENT REQUIRED IAW AMM 33-51-38-400-002-A REV 103. : REPLACED EPSU BATTERY 15WL IAW AMM 33-51-38-400-002-A REV 103. MX ACTION IS ACCEPTABLE.
Part: BATTERY — FAILED (ZONE 200) · airframe 31,358 hrs · 13,575 cycles
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING OPS CHK, FOUND EPSU BATTERY 10WL INOPERATIVE. REPLACEMENT REQUIRED IAW AMM 33-51-38-400-002-A REV. 103. REPLACED EPSU BATTERY 10WL IAW AMM 33-51-38-400-002-A REV 103. MX ACTION IS ACCEPTABLE.
2023
Part: THERMOCOUPLE — UNCONTROLLABLE (ZONE 400) · airframe 24,220 hrs · 10,625 cycles
DISCREPANCY: REFERENCE LP324518 ITEM 1:ENG 2 EGT OVERLIMIT PERFORMED ECAM ACTION ENGINE SHUT DOWN IN FLIGHT. ACCOMPLISHED TS WORKSCOPE MDDR 1193027 AND PERFORMED POWER ASSURANCE CHECK IAW WORK SCOPE TSWS 01407 MDDR #1193027 REF LP 324520 ITEM 3, LP324521 ITEM 1 &ITEM 2 AND LP324529 ITEM 1 NO FURTHER DEFECT NOTED.
2021
Part: FLOORBEAM — CORRODED (ZONE 100) · airframe 19,964 hrs · 8,411 cycles
DISCREPANCY: REFERENCE PEMCO N/R # 11661.0390 FWD WET AREA FR16 FLOOR BEAM Y-254 CORR )OED CORRECTIVE ACTION: REMOVED AND REPLACED WET AREA FR 16 FLOOR BEAM Y-254 IAW A321 SRM ,1-72-11.
Part: VALVE — BINDING (E/E BAY VENT) · airframe 18,885 hrs · 7,937 cycles
LP151814 ITEM 1 --- VENT AVNCS SYS FAULT ECAM AT APPROX 1500' --- CORRECTIVE ACTION -- REMOVED AND REPLACED SKIN AIR OUTLET VALVE IAW AMM 21-26-53-000-001-A AND AMM 21-26-53-400-001-A OPS CHECK GOOD
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 18,010 hrs · 7,557 cycles
LP1284912 ITEM 1: POST DOOR SLIDE CHANGE, FOUND EPSU FAULTS. REPLACED EPSU BATTERIES AT 10WL,11WL,12WL & 13WL. OPS CHECKED NORMAL. REF AMM 33-51-38-000-002-A AND 33-51-38-400-002-A
2018
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 10,361 hrs · 4,304 cycles
DURING HEAVY CHECK, EMERGENCY LIGHT BATTERY 13WL FAILED TO TEST THRU MCDU. REMOVED AND REPLACED EPSU ASSY IAW AMM 33-51-38-PB, 401, CONF 00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 10,361 hrs · 4,304 cycles
DURING A HEAVY CHECK, EMERGENCY LIGHT BATTERY 11WL FAILED TO TEST THRU MCDU. REMOVED AND REPLACED EPSU ASSY IAW AMM 33-51-38-PB 401, CONF 00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 10,361 hrs · 4,304 cycles
DURING A HEAVY CHECK, THE EMERGENCY LIGHT BATTERY AT 15WL FAILED TO TEST THRU MCDU. REMOVED AND REPLACED EPSU ASSY IAW AMM 33-51-38-PB 401, CONF 00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.
Part: UNKNOWN — ODOR (CABIN) · airframe 10,209 hrs · 4,234 cycles
FUME EVENT AFT OF AIRCRAFT ON TAXI OUT. FA AND PAX COMPLAINED OF A WET SOCKS ODOR. TROUBLESHOT IAW TSM 71-00-00-810-802-A. RAN PACKS, THE NR 1 & 2 ENGINES, APU BORESCOPED AND FOUND NO FUMES AT THIS TIME. AIRCRAFT OK FOR SERVICE.
2017
Part: HMU — MALFUNCTIONED (NR 2 ENGINE) · airframe 6,399 hrs · 2,657 cycles
DURING CRUISE ALTITUDE, THE NR 2 ENGINE WAS UNRESPONSIVE TO THRUST LEVERS AND AUTO THRUST LEVERS. THE NR 2 ENGINE FROZE AT 95% N1. THE CREW SHUTDOWN THE ENGINE AND SECURED AT FL 150. MAINTENANCE REMOVED AND REPLACED THE NR 2 HMU ASSEMBLY AND OPS CHECKED GOOD IAW AMM 73-21-10, PAGE 401, AIRCRAFT RETURNED TO SERVICE.
Part: FIRE BOTTLE — DEFECTIVE (APU FIRE) · airframe 5,596 hrs · 2,335 cycles
APU FIRE EXTINGUSHER LIGHT ILLUMINATED. REMOVED AND REPLACED THE APU FIRE BOTTLE & SQUIB IAW AMM 26-22-41 PB 401 & 26-22-42 PB 401. OPS CHECKED GOOD. APU RUN TESTED GOOD IAW AMM 49-00-00-710-010A.