N707AA

JOHN C STAHR VANS RV-8 · 2012 · Fixed-wing single-engine · 1 engine · 2 seats · Valid Registration

Registered owner: STAHR JOHN C, FL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

40 reports on file, 1996-07-11 – 2001-11-04.

WARNING INDICATION · 2001-11-04 Unresolved
ATA 3411

Part: PITOT LINE — CONTAMINATED (PITOT/STATIC SYS)

ON REPOSITION FLIGHT DUE TO IMPENDING HURRICANE ON TAKEOFF ROLL. NO CAPTAINS AIR SPEED INDICATION FLUSHED SYSTEM PER MM 34-11-0 PAGE 209 AND PERFORMED OPS CHECK PER MM 34-11-0. OPS CHECK OK. (M)

Source: SDR 2002F00057
WARNING INDICATION · 2001-11-04 Unresolved
ATA 3411

Part: PITOT LINE — CONTAMINATED (PITOT/STATIC SYS)

ON REPOSITION FLIGHT DUE TO IMPENDING HURRICANE ON TAKEOFF ROLL. NO CAPTAINS AIR SPEED INDICATION FLUSHED SYSTEM PER MM 34-11-0 PAGE 209 AND PERFORMED OPS CHECK PER MM 34-11-0. OPS CHECK OK. (M)

Source: SDR 2002F00058
OTHER · 2001-06-06 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE)

TUL - FOUND CORROSION ON UNDERSIDE OF FLOORBEAM AT DOOR SILL AREA FRAME 62 INBOARD OF ROLLOUT DEVICE. CORROSION IS HALF WAY THROUGH FLOORBEAM. INSTALLED FABRICATED SECTION OF FLOORBEAM AT DOOR SILL AREA STATION 4097 (FRAME 62) PER SRM 51-72-10. (M)

Source: SDR AALA20011199
NO TEST · 2001-05-22 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, LEFT AFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY CHARGER SYSTEM FOR LEFT OVERWING EMERGENCY EXIT LIGHT. (M)

Source: SDR AALA20011121
Earlier reports · 1996–2000 · 36 reports

2000

NO TEST · 2000-12-29 Unresolved
ATA 3397

Part: WIRE — DAMAGED (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR LIGHT AT SEAT 6D THROUGH 15D INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR LIGHT WIRE AT SEAT 5 AND 6. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20002160
NO TEST · 2000-11-17 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DISCONNECTED (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT FROM ROW 6D TO 15D INOPERATIVE. RE-SECURED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20001957
NO TEST · 2000-11-17 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DISCONNECTED (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT BETWEEN 6D AND 15D INOPERATIVE. RE-SECURED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20001959
NO TEST · 2000-08-06 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

MIA DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT OVER FORWARD GALLEY DOOR INOPERATIVE. REPLACED LIGHT SYSTEM GROUND CHECK NORMAL OPERATION.

Source: SDR AALA20001286
NO TEST · 2000-03-03 Unresolved
ATA 3397

Part: WIRE — BROKEN (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT OVERWING EXIT INOPERATIVE. REPAIRED BROKEN WIRE IN OVERWING LIGHT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20000392
NO TEST · 2000-01-06 Matched by certificate designator
ATA 3350

Part: CONNECTOR — LOOSE (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT ROW 14-18 INOPERATIVE. SECURED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR AT ROW 14-18. SYSTEM GRUOND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20000034

1999

NO TEST · 1999-07-22 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE, EMERGNCY EXIT FLOOR PATH LIGHTING FROM ROWS 25 TO 28 DEF INOPERATIVE. REPAIRED WIRE TO EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA991075
OTHER · 1999-06-16 Matched by certificate designator
ATA 5321

Part: FLOOR — CORRODED (BS 1183)

TUL - EXFOLIATED CORROSION ON FLOOR PAN EXTRUDING UNDER AND CAUSING BULGING TO FLOOR STRAP ON FORWARD SIDE OF STATION 1183 BULKHEAD, AT LOWER RIGHT CORNER OF VAULT DOOR FRAME, RBL 14 - RBL 24. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-2 AND FLOOR PAN ON FORWARD SIDE OF STATION 1183, LOWER RIGHT CORNER OF VAULT DOOR FRAME RBL 14 - RBL 24. (M)

Source: SDR AALA990885
OTHER · 1999-06-15 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (BS 312)

TUL - HFEC INDICATES CRACK IN FUSE SKIN AT FORWARD ENTRY DOOR LOWER HINGE CUTOUT. INSTALLED DOUBLER PER BSB 727-53-0198 PAGE 32, FIG 4 DETAIL IV. (M)

Source: SDR AALA990884
OTHER · 1999-06-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 380)

TUL - CABIN FLOORBEAM CORRODED TOP SIDE RBL 52-62. REMOVED CORROSION AND INSTALLED REPAIRED DOUBLER PER AARD 53-10-07-2. (M)

Source: SDR AALA990886

1998

OTHER · 1998-06-18 Matched by certificate designator
ATA 5511

Part: SPAR CAP — CORRODED (RT HORIZ STAB)

TUL - RIGHT HORIZONTAL STABILIZER T/E SPAR CAP HAS CORROSION UNDER DOUBLER, BETWEEN NR 6 AND NR 7 ELEVATOR HINGES. TREATED, PRIMED, AND PAINTED AREA, INSTALLED FILLER AND DOUBLER IAW SRM 55-10-6 AND ESO 11-6-97, DATED 6-3-98. TST: 46,450. CYCLES: 24,085. (X)

Source: SDR AALA981194
NO TEST · 1998-05-06 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DISCONNECTED (CABIN)

MIA - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHT INOPERATIVE. RESECURED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA980902
NO TEST · 1998-03-08 Matched by certificate designator
ATA 3350

Part: CLIP — OUT OF ADJUST (CABIN)

RDU - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT IN VENTRAL STAIR INOPERATIVE. ADJUSTED CLIPS ON EMERGENCY EXIT CHARGER FOR VENTRAL STAIR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA980450
NO TEST · 1998-02-06 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

MIA - DURING OVERNIGHT CHECK, FOUND EMERGENCY FLOOR LIGHTING AT PASSENGER SEAT ROWS 9 TO 15 INOPERATIVE. REPLACED BROKEN WIRE AT EMERGENCY FLOOR LIGHT PASSENGER SEAT ROWS 9 TO 15. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA980253

1997

FLUID LOSS; INFLIGHT SEPARATION · 1997-08-11 Matched by certificate designator
ATA 2810

Part: FUEL CAP — DEPARTED A/C (LT OVERWING)

JFK - FLT 803 - AFTER TAKEOFF LGA DURING CLIMB-OUT, NR 1 FUEL QTY BEGAN DECREASING AT AN ABNORMAL RATE. ACCOMPLISHED ABNORMAL PROCEDURE FOR DECREASING FUEL QTY AND AIRCRAFT DIVERTED TO JFK, LANDING WITHOUT INCIDENT. REPLACED LEFT OVERWING FUEL CAP WHICH HAD DEPARTED THE AIRCRAFT. SYSTEM LEAK AND GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA971444
OTHER · 1997-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 676-680)

TUL - CORROSION STR 27L OUTBOARD SIDE AND INSIDE CHANNEL STA 676 - STA 680. REMOVED CORRODED SECTION OF STRINGER AND SPLICED IN NEW SECTION PER SRM 53-10-3, FIG 1. TST: 44,187 HOURS. CYCLES: 22,987. (X)

Source: SDR AALA971250
NO TEST · 1997-05-09 Matched by certificate designator
ATA 3350

Part: CONNECTOR — BROKEN (CABIN)

MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN AFT SECTION OF MAIN CABIN FOUND INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTOR IN AFT SECTION OF MAIN CABIN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA970888

1996

NO TEST · 1996-11-12 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

IAH - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR LIGHTS AT FIRST CLASS DIVIDER INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR LIGHT WIRE AT FIRST CLASS DIVIDER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA961636
OTHER · 1996-07-11 Matched by certificate designator
ATA 5311

Part: FRAME — GOUGED (BS 783.95)

TL - HOLE AND GOUGE IN RADIUS OF BELT FRAME. REPAIRED FRAME PER SRM 53-10-4, FIGURE 2. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961050
OTHER · 1996-07-11 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (BS 1136-1166)

FIVE PLACES OF CORROSION ON RIGHT AFT LAVATORY FLOOR WEB, EACH BEING APPROXIMATELY 2 INCHES BY 6 INCHES IN A 20 SQUARE INCH AREA WITH 2 PLACES PASSED LIMITS. REMOVED CORROSION SECTION, REPLACED WITH SHIMMED DOUBLER PER SRM 51-40-2. ALODINED, PRIMED AND PAINTED. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961035
OTHER · 1996-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 480-488)

TUL - CORROSION ON STR 28L, OUTBOARD SIDE. REMOVED CORROSION STA 28L STA 480 - STA 488. REPAIRED STR 28L, STA 484 PER SRM 53-10-3. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961040
OTHER · 1996-07-11 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 720)

TUL - CORROSION ON SHEAR TIE, STA 720 FROM STR 28L - STR 28R. REPLACED WITH NEW SHEAR TIE. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961051
OTHER · 1996-07-11 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 480-500)

TUL - FOUND CORROSION ON SKIN STATION 480 TO 500, STATION 28 LEFT. INSTALLED REPAIR PER SRM 53-30-3, STATION 480 TO 500, STRINGER 28 LEFT. (M)

Source: SDR AALA961038
OTHER · 1996-07-11 Matched by certificate designator
ATA 5311

Part: FRAME — MISDRILLED (BS 804.95)

TUL - HOLE DRILLED IN RADIUS OF FRAME. REPAIRED FRAME PER SRM 53-10-4, FIGURE 2. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961049
OTHER · 1996-07-11 Matched by certificate designator
ATA 5720

Part: STIFFENER — CORRODED (WS 245)

TUL - LEFT WING FORWARD SPAR, CORROSION ON VERTICAL STIFFENER, FSS 245. REPLACED VERTICAL STIFFENER PER SRM 51-10-4, PAGE 4. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961033
OTHER · 1996-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 680-710)

TUL - CORROSION ON STA 27R. REMOVED STA 27R, STA 680 - STA 710. INSTALLED NEW SECTION OF STRINGER PER 53-10-3. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961041
OTHER · 1996-07-11 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 700)

REMOVED SHEAR TIE, REPLACED WITH NEW SHEAR TIE, STA 700, 28LT-28RT PER 53-10-3. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961043
OTHER · 1996-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 495-500)

TUL - FOUND CORROSION ON STRINGER 27R . REPAIRED STRINGER PER SRM 53-10-3 PG 3-4. REMOVED CORROSION PER SRM 51-10-6. (M)

Source: SDR AALA961039
OTHER · 1996-07-11 Matched by certificate designator
ATA 5720

Part: STIFFENER — CORRODED (WS 255)

TUL - LEFT WING FORWARD SPAR, CORROSION ON VERTICAL STIFFENER FSS 255. REPLACED STIFFENER PER SRM 51-10-4. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961032
OTHER · 1996-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 680-720)

TUL - CORROSION ON STR 28R, STA 680 TO STA 720 PLUS 3 INCHES. REMOVED AND INSTALLED NEW STRINGER PER SRM 51-10-1, PAGE 4. ALODINED, PRIMED AND PAINTED PER MM 51-20-0. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961036
OTHER · 1996-07-11 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 480-500)

TUL - CORROSION ON BELLY SKIN. INSTALLED DOUBLER PER SRM 53-30-3, PAGES 12-14A. REMOVED CORROSION. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961044
OTHER · 1996-07-11 Matched by certificate designator
ATA 5311

Part: FRAME — CORRODED (BS 720)

TUL - CORROSION ON LOWER BELL FRAME, STA 720. INSTALLED REPAIR ON BELL FRAME PER SRM 53-10-4. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961048
INADEQUATE Q C · 1996-07-11 Matched by certificate designator
ATA 5311

Part: FRAME — DOUBLE DRILLED (BS 804.95)

TUL - DOUBLE HOLE DRILLED IN BELT FRAME. REPAIRED FRAME PER SRM 53-10-4, FIGURE 2. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961031
OTHER · 1996-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 704)

TUL - CORROSION ON STR 28L, STA 704. INSTALLATED NEW SECTION OF STR 28L, STA 680 TO STA 720. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961034
OTHER · 1996-07-11 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 950-1000)

TUL - HEAVY CORROSION ON STR 29R FROM STA 950E TO STA 1000. REMOVED AND REPLACED STR 29R, STA 950-STA 1000 IAW SRM 53-10-3, AND INSTALLED DOUBLER AND TRIPLER IAW SRM 53-30-3, FIGURE 3, AND ESO 11697, DATED 6-10-96. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961037
OTHER · 1996-07-11 Matched by certificate designator
ATA 5320

Part: STRAP — CORRODED (BS 610-620)

TUL - CORROSION ON STRAP. REMOVED CORROSION, INSTALLED NEW STRAP FRAME 610-620 PER SRM 53-10-3. TST: 41,665 HOURS. CYCLES: 21,768. (X)

Source: SDR AALA961042