14 reports on file, 2023-10-30 – 2024-11-30.

FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2024-11-30 Matched by certificate designator
ATA 7261

Part: OIL SYSTEM — LEAKING (NR 1 ENGINE) · airframe 4,110 hrs · 1,593 cycles

FUME EVEN: WHILE DESCENDING THROUGH 1100 UN VMC STRONG SMELL IN COCKPIT FOLLOWING EQRH PROCEDURE ISOLATING PACK 1 SMELL SLOWLY WENT AWAY-TI 2100-2004-NEO ACCOMPLISHED ON WO# 337985. DURING INSPECTIONS FOUND OIL CONTAMINATION IN ENG 1 OPV, LPC, & HPC. PERFORMED DECONTAMINATION OF ECS REF AMM 21-00-00. SEE LBP 3608228-1 FOR ENG 1 OIL CONTAMINATION

Source: SDR GTIA2024120238566
SMOKE/FUMES/ODORS/SPARKS · 2024-11-28 Matched by certificate designator
ATA 2150

Part: ECS — CONTAMINATED · airframe 4,097 hrs · 1,587 cycles

FUME EVENT: AN ACRID SMELL OCCURRED IN THE FLIGHT DECK ISOLATING PACK 1 FIXED THE ISSUE-PERFORMED EO 7100-2301 AND PERFORMED DECONTAMINATION OF ECS IAW AMM 21-00-00. FOUND NO ODORS OR FUME SMELLS. A/C GOOD FOR CONT SERVCIE

Source: SDR GTIA2024120238563
SMOKE/FUMES/ODORS/SPARKS · 2024-11-26 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 1) · airframe 4,084 hrs · 1,580 cycles

FUME EVENT PRESENT ODOR SMELLED IN COCKPIT WHILE DESCENDING BELOW 6,000 SELECTING PACK 1 OFF RESOLVED THE ISSUE.-APPLIED TSM 05-50-00. DUE TO CREW REPORT AND HISTORY, ISOLATED TO PACK 1. NO ODOR PRESENT. SEE NEXT LOG PAGE 3608208-2 FOR DEFERRAL

Source: SDR GTIA2024120238559
SMOKE/FUMES/ODORS/SPARKS · 2024-11-26 Matched by certificate designator
ATA 2150

Part: ECS — CONTAMINATED · airframe 4,082 hrs · 1,579 cycles

FUME EVENT- DURING DESCENT PASSING THRU 5,000FT, STRONG ODOR PRESENT IN COCKPIT. PACK 1 OFF RESOLVED THE ISSUE-PERFORMED PACK #1 DECONTAMINATION OF ECS IAW AMM 21-00-00 AND R/R BOTH PACK FILTERS IAW AMM 22-21-41 OPS CHECK OK LEAK CHECK OK A/C GOOD FOR CONTINUED SERVICE

Source: SDR GTIA2024120238560
SMOKE/FUMES/ODORS/SPARKS · 2024-11-20 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 1) · airframe 4,038 hrs · 1,558 cycles

MUST SOCK SMELL ON DESCENT PACK 1 OFF ISOLATED SMELL-TROUBLESHOT IAW TSM 05-50-00-810-831-A, FOUND PACK 1 TO BE THE SOURCE OF AQE, REF LP 3405047-2 FOR PACK 1 DEFERRAL , A/C OK FOR CONT SVC

Source: SDR GTIA2024112238541
SMOKE/FUMES/ODORS/SPARKS · 2024-11-04 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (ZONE 200) · airframe 3,961 hrs · 1,520 cycles

FUME EVENT F/A REPORTED DIRTY SOCK SMELL IN CABIN-PERFORMED TSM 05-50-00 FOR CAUSE OF ODOR , CHEKED ENGINES AND APU FOR LEAKAGES , NONE NOTED , APPLIED CREW REPORT TO DECISON TABLE AND SUSPECT LEFT PACK AS CAUSE OF ODOR , SEE LOG PAGE 3405019-1 FOR PACK MEL / DEACTIVATION MOC 68056 NOTIFIED

Source: SDR GTIA2024110838507
SMOKE/FUMES/ODORS/SPARKS · 2024-10-22 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 3,868 hrs · 1,478 cycles

POSSIBLE FUME EVENT COMING THRU 10,000 FT-REF LP 3389186-1 FOR CORRECTIVE ACTION. PERFORMED PACK BURNOUT TSM 05-50-00-810-831-A. NO SMELL NOTICED. SMELL WAS LOCALIZED IN MID CABIN NEAR OVERWING DOORS. PASSENGER MAY HAVE SPILLED SOMETHING ON CARPET. DURING PACK BURNOUT W/APU DID NOT NOTICE SMELL COMING FROM GASPER VENTS OF PSU'S, CONTINUED ON LP 3389186-2

Source: SDR GTIA2024102438470
SMOKE/FUMES/ODORS/SPARKS · 2024-10-15 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 3,873 hrs · 1,482 cycles

DECENDING THROUGH 10000 FT WE GOT A DIRTY SOCK SMELL THEN AGAIN AS WE PUT GEARS DOWN AT 2500 FEET-COMPLIED WITH TSM 71-00-00-810-801. RAN APU & BOTH ENGINES NO ODOR NOTICED. LEVEL -A- PROCEDURE COMPLIED WITH. A/C OK FOR SVC.

Source: SDR GTIA2024101838455
SMOKE/FUMES/ODORS/SPARKS · 2024-09-16 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 1) · airframe 3,540 hrs · 1,337 cycles

DIRTY SOCK SMELL IN THE COCKPIT ON DESCENT POSS FUME EVENT-REF TSM 05-50-00-810-831, SUSPECT PACK 1 POSSIBLE CAUSE. WENT BACK 2 MONTHS NO PREVIOUS WRITE UPS. REF LP 3370355-2 FOR PACK DEFERRAL.

Source: SDR GTIA2024091738376
SMOKE/FUMES/ODORS/SPARKS · 2024-05-26 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 2,342 hrs · 859 cycles

FA REPORT FUMES SMELL AT THE REAR OF THE A/C AT 10,000' -PERFORMED IDENT. OF CAUSE FOR CABIN ODOR PER TSM 05-50-00-810-831-A, PACK 1, APU AND BOTH ENGINES RUN WITH F/CREW ASSISTANCE. COULD NOT DUPLICATE FAULT, NO DISCREPANCIES NOTED AT THIS TIME. A/C OK FOR SERVICE. MOC 68083.

Source: SDR GTIA2024052838144
SMOKE/FUMES/ODORS/SPARKS · 2024-05-25 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 2) · airframe 2,335 hrs · 856 cycles

AFT FA CALLED DURING DESCENT TO REPORT DIRTY SOCK SMELL #2 PACK SHUT OFF AND SMELL SEEMED TO DISSIPATE -ISOLATED AQE TO PACK 2 IAW TSM 05-50-00-810-831-A

Source: SDR GTIA2024052838143
SMOKE/FUMES/ODORS/SPARKS · 2024-05-23 Matched by certificate designator
ATA 2150

Part: A/C PACK — ODOR (NR 1) · airframe 2,319 hrs · 850 cycles

FUME FROM PACK 1 ON DESCENT.-REF TSM 05-00-810-831-A PERFORMED ECS DECONTAMINATION OF PACK #1 IAW AMM 21-00-00. NO SMELL OR ODOR NOTED IN THE CABIN.

Source: SDR GTIA2024052438140
SMOKE/FUMES/ODORS/SPARKS · 2024-04-23 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 1,948 hrs · 725 cycles

AT ABOVE 4,000' 5 MINUTES PRIOR TO TOUCHDOWN PAX & F/A'S EXPERIENCED FUME EVENT ROWS 25 AFT, LASTED ABOUT 3 MINUTES.-PERFORMED TSM 05-50-00-810-831. RAN BOTH PACKS WITH APU IAW AMM 21-52-00 AND UNABLE TO DUPLICATE ODOR.(ODOR REPORTING SHEET NOT PROVIDED) MOC 70180

Source: SDR GTIA2024042338079
Earlier reports · 2023 · 1 report

2023

VIBRATION/BUFFET · 2023-10-30 Matched by certificate designator
ATA 5100

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 92 hrs · 30 cycles

"AIRCRAFT REQUIRES A POST MAINTENANCE FLIGHT DUE TO MID CABIN NOISE AND VIBRATION.-POST MAINTENANCE FLIGHT COMPLETED. NOISE / VIBRATION STILL PRESENT."

Source: SDR GTIA2023110337577