Part: BOTTLE — DEPLETED (ZONE 800) · airframe 6,774 hrs · 2,775 cycles
R3 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00
Part: ECS — CONTAMINATED (ZONE 100) · airframe 5,847 hrs · 2,376 cycles
STRONG SOCK ODOR DURING TAKEOFF. PACK 1 REMOVED, ODOR DESCRIPTION OF ODOR/FUMES: PERSISTENT, HYDRAULIC & MUSTY DRY ODOR. APPARENT CABIN SOURCE: CABIN AIR SUPPLY VENTS. FLIGHT DECK & FWD CABIN. NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION REQURIED. R & R CABIN RECIRCULATION FILTER CARTRIDGES IAW AMM 21-21-41. PERFORMED LEVEL A DECONTAMINATION OF (ECS) IAW AMM 21-00-00-615-802-A. OPS CHKS GOOD. NO ODORS FOUND.
Part: KNOB — MISSING (MEGAPHONE) · airframe 3,069 hrs · 1,201 cycles
L1 MEGAPHONE KNOB MISSING-R&R L1 MEGAPHONE IAW AMM 25-65-51 & SPIRIT A321 EMER EQUIP LAYOUT
Part: BOTTLE — LOW PRESSURE (ZONE 800) · airframe 2,479 hrs · 944 cycles
R4 DOOR ASSIST BOTTLE REQ SVC-SVC'D R4 DOOR IAW AMM 52-10-00. LEAK AND OPS CHECK NORMAL
Part: BOTTLE — LOW PRESSURE (R3 DOOR ASSIST) · airframe 1,154 hrs · 417 cycles
R3 DOOR ASSIST BOTTLE NEED SERVICING-SERVICED R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00 LEAK TEST GOOD
Part: BOTTLE — LOW PRESSURE (R3 DOOR ASSIST) · airframe 956 hrs · 341 cycles
AFT R3 DOOR ASSIST BOTTLE REQUIRES SERVICING -AFT R3 DOOR ASSIST BOTTLE HAS BEEN SERVICED TO THE CORRECT PSI IAW AMM 52-10-00.
Part: BOTTLE — LOW PRESSURE (R3 DOOR ASSIST) · airframe 852 hrs · 304 cycles
R3 DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED R3 PASSENGER DOOR IAW AMM 52-10-00
Part: INDICATOR — FALSE INDICATION (R AFT OVERWING) · airframe 305 hrs · 128 cycles
DOOR R AFT OVERWING EXIT OPEN INDICATION IN FLIGHT ( ECAM DOOR PAGE INDICATIONS OVERWING EMERGENCY EXITS â OPEN INDICATION )--