Accident & incident history

Boeing 727-227 Serious injury Part 121operator not named in the NTSB record
Source: NTSB case CHI98LA127
BOEING 727-227 No injuries Part 121operator not named in the NTSB record
Source: NTSB case LAX85IA023

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

58 reports on file, 1997-01-02 – 2001-03-29.

NO TEST · 2001-03-29 Matched by certificate designator
ATA 3350

Part: MODULE — INOPERATIVE (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE FIRST CLASS EMERGENCY EXIT LIGHT DIM. REPLACED FIRST CLASS EMERGENCY EXIT LIGHT MODULE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20010663
NO TEST · 2001-02-08 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PROXIMITY LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT SEGMENTS AT ROW 6, 8 AND 26. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20010232
OTHER · 2001-01-23 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (WING)

TUL - FOUND LOWER WING SKIN ABOVE RIGHT PRIMARY HEAT EXCHANGER IS INFECTED WITH MODERATE TO HEAVY CORROSION LBL 32-RBL 32 STRINGER 3-5, STATION 805-820. REMOVED CORROSION AND INSTALLED DOUBLER AND TRIPLER .080, 2024-T3 (TWO EACH) PER SRM 57-30-3. (M)

Source: SDR AALA20010158
OTHER · 2001-01-22 Matched by certificate designator
ATA 5320

Part: PAN — CORRODED (LAVATORY)

TUL - FOUND LAVATORY PAN CORRODED AROUND LAV TANK WEB FORWARD MOUNTS AND SURROUNDING WEB LBL 36, BS 1146. BLENDED OUT CORROSION AND INSTALLED DOUBLER PER SRM 51-40-2 PAGE 1. (M)

Source: SDR AALA20010160
OTHER · 2001-01-19 Matched by certificate designator
ATA 5320

Part: ANGLE — CORRODED (CARGO BAY)

TUL - FOUND AIRCRAFT CARGO DOOR AFT CUTOUT THRESHOLD LOWER CHORD ANGLE CORRODED FORWARD CORNER BETWEEN STATION 950D AND 950E. REPAIRED PER ESO11697 DATED 1/19/2001. (M)

Source: SDR AALA20010162
OTHER · 2001-01-19 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (WING)

TUL - FOUND CORROSION ON BOTTOM OF CENTER WING SKIN ABOVE LEFT AND RIGHT HEAT EC4. REMOVED CORROSION AND INSTALLED TWO 2024T3-.080 TRIPLERS, ONE SET BETWEEN STRINGER 5/6 AND ONE SET AT STRINGER 3 ENGINE DISPOSITION DATED 1-13-2001. (M)

Source: SDR AALA20010161
OTHER · 2001-01-19 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE)

TUL - FOUND CORROSION ON TOP OF FORWARD UPPER CHORD OF FS 1130 FLOORBEAM LBL 26-60. BLENDED OUT CORROSION AND INSTALLED REPAIR STRAP PER AARD 53-10-07-1. (M)

Source: SDR AALA20010163
OTHER · 2001-01-18 Matched by certificate designator
ATA 7230

Part: BLADE — CRACKED (NR 1 ENGINE)

TUL - FOUND NR 1 ENGINE FAN BLADE CRACKED AT FIR TREE AS VIEWED FROM AFT SIDE OF DISH. REMOVED AND REPLACED FAN ASSY PER WORK CARD 11-17. (M)

Source: SDR AALA20010097
OTHER · 2001-01-18 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE)

TUL - FOUND CORROSION ON SKIN SURFACE. REMOVED CORROSION AND INSTALLED HI-LOK WITH WASHER PER ESO 11697 DATED 1-16-01. (M)

Source: SDR AALA20010165
OTHER · 2001-01-18 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE)

TUL - FOUND CORROSION ON TOP SKIN SURFACE. REMOVED CORROSION AND INSTALLED REPAIR STRAP PER ESO 11697 DATED 1-15-2001. (M)

Source: SDR AALA20010164
OTHER · 2001-01-17 Matched by certificate designator
ATA 5330

Part: LAP JOINT — CORRODED (FUSELAGE)

TUL - FOUND STRINGER 26L SKIN LAP 4 INCH LONG AREA BULGING AT RIVETS STATION 661-665. FOUND CORROSION IN SKIN LAP. CUT OUT CORRODED AREA AND INSTALLED DOUBLER AND FILLER PER SRM 53-30-3 FIG 5 SHEET 5. (M)

Source: SDR AALA20010159
Earlier reports · 1997–2000 · 47 reports

2000

NO TEST · 2000-11-17 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (AIRSTAIR)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AIR STAIR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT AIR STAIR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20001913
NO TEST · 2000-11-17 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT COCKPIT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT COCKPIT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20001912
NO TEST · 2000-11-17 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, CABIN FLOOR PATH EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED CABIN FLOOR PATH EMERGENCY EXIT LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20001914
NO TEST · 2000-08-12 Unresolved
ATA 3397

Part: WIRE — BROKEN (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS IN AFT CABIN INOPERATIVE. REPAIRED LIGHT STRIP WIRE IN AFT AREA. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20001333
NO TEST · 2000-08-02 Unresolved
ATA 3397

Part: WIRE — BROKEN (CABIN)

DFW DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS AT ROW 15 AND FORWARD OF OVERWING EXIT MARKERS INOPERATIVE. REPAIRED LIGHT STRIP WIRE BETWEEN ROW 14 AND 15. SYSTEM GROUND CHECK NORMAL OPERATION.

Source: SDR AALA20001266
NO TEST · 2000-05-20 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DEFECTIVE (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT AT SEATS 27 TO 28 ON RIGHT SIDE INOPERATIVE. REPLACED BAD CONNECTOR AT SEAT 27. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20000812
OTHER · 2000-04-19 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE)

TUL - CORROSION AROUND NUTPLATES ON FLOORBEAM 1070 LOWER FORWARD FLANGE FROM LBL 15 TO RBL 20. INSTALLED STRAP ON FLOORBEAM PER ESO 11697 DATED 4-11-00. (X)

Source: SDR AALA20000693
NO TEST · 2000-04-10 Matched by certificate designator
ATA 3350

Part: LIGHT — MALFUNCTIONED (CABIN)

TUL - FOUND MAIN EMERGENCY ESCAPE PATH MARKING LIGHT HARNESS DIM. INSTALLED NEW EPM FLAT CONDUCTOR A3-06-0720-101 BETWEEN STATION 1030-1090. OP CHECKED LIGHT, CHECKED OK MM 33-50. (M)

Source: SDR AALA2000680
NO TEST · 2000-03-28 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

MIA - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS AFT OF REAR GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP AFT OF REAR GALLEY. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20000553

1999

NO TEST · 1999-12-21 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, EXTERIOR EMERGENCY EXIT L1 DOOR LIGHT INOPERATIVE. REPLACED EXTERIOR EMERGENCY EXIT L1 DOOR LIGHT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA991954
OTHER · 1999-11-23 Matched by certificate designator
ATA 5510

Part: CASTING — CORRODED (HORIZ STABILIZER)

TUL - HORIZONTAL STABILROSION ON BORES, LEFT SIDE. REMOVED CORROSION ER SRM 55-10-2 AND FABRICATED NEW BUSHING PER 55-10-2. TST: 72,812.33 HOURS. CYCLES: 47,830. (X)

Source: SDR AALA991783
OTHER · 1999-11-23 Matched by certificate designator
ATA 5510

Part: CASTING — CORRODED (HORIZ STABILIZER)

TUL - HORIZONTAL STABILIZER HINGE LUGS RIGHT SIDE, BOTH INBOARD AND OUTBOARD HAS CORROSION. REMOVED CORROSION PER SRM 55-10-2. FABRICATED NEW BUSHING PER 55-10-2. TST: 72,812.33 HOURS. CYCLES: 47,830. (X)

Source: SDR AALA991782
OTHER · 1999-11-23 Matched by certificate designator
ATA 5510

Part: CASTING — CORRODED (HORIZONTAL STAB)

TUL - VERTICAL FIN - HORIZONTAL STABILIZER ATTACH LUGS HAD CORROSION IN BORE, BOTH LEFT AND RIGHT. REMOVED CORROSION ON RIGHT LUG PER SB 727-55-7 AND SRM 55-30-6. REMOVED CORROSION ON LEFT LUG PER ESO 11697 DATED 11-22-99. (X)

Source: SDR AALA991784
OTHER · 1999-11-21 Matched by certificate designator
ATA 5510

Part: BEAM — CORRODED (HORIZONTAL STAB)

TUL - HEAVY CORROSION ON TOP OF LEFT HORIZONTAL STABILIZER UPPER REAR T/E BEAM. INSTALLED DOUBLER OVER DAMAGED AREA PER 55-10-6. TST: 72,812 HOURS. CYCLES: 47,830. (X)

Source: SDR AALA991779
OTHER · 1999-11-19 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 572-580)

TUL - CORROSION ON BILGE SIDE OF SKIN OUTBOARD OF STR 28L STA 572 - STA 580. INSTALLED EXTERNAL DOUBLER PER SRO 53-30-3. TST: 72,812.33 HOURS. CYCLES: 47,830. (X)

Source: SDR AALA991781
OTHER · 1999-11-17 Matched by certificate designator
ATA 5320

Part: ANGLE — CORRODED (BS 208)

TUL - HEAVY CORROSION ON STRUCTURE NOSE WHEELWELL JUST OUTBOARD OF LEFT TRUNNION CAP S70 208 WL 178 LBL 20-23. REMOVED/TREATED CORROSION, INSTALLED DOUBLER AARD 51-20-01.5 S58 NR 3091337. TST: 72,812 HOURS. CYCLES: 47,830. (X)

Source: SDR AALA991780
NO TEST · 1999-07-04 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, RIGHT EMERGENCY EXIT FLOOR PATH LIGHTING BY AFT DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA990992

1998

PARTIAL RPM/PWR LOSS; WARNING INDICATION · 1998-11-17 Matched by certificate designator
ATA 7250

Part: TURBINE — FAILED (NR 1 ENGINE)

MIA - FLT T1301 - EN ROUTE MIA/EWR AFTER TAKEOFF ABOUT 1,600 FEET LOST POWER, DUMPED FUEL, AND RETURNED AND LANDED MIA WITHOUT FURTHER INCIDENT. REPLACED NR 1 ENGINE, PERFORMED ENGINE RUN-UP, AND LEAK CHECKED. SYSTEM GROUND CHECKED NORMAL OPERATION. SHOP FINDINGS: THE ENGINE (SN 666101) WAS SHUT DOWN DUE TO TURBINE FAILURE. CONFIRMED SOURCE OF FAILURE WAS CAUSED BY TWO FIRST STAGE TURBINE BLADES. THE TWO EACH BLADES EXPERIENCED INCREASED RATE OF CREEP AND SUBSEQUENT STRESS RUPTURE ACROSS THE SPAN OF THE BLADE. (X)

Source: SDR AALA982083
NO TEST · 1998-05-09 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA980936
NO TEST · 1998-05-09 Matched by certificate designator
ATA 3350

Part: LIGHT — MALFUNCTIONED (CABIN)

DFW - DURNIG OVERNIGHT MAINTENANCE, AFT EMERGENCY EXIT LIGHT IS BLINKING OFF AND ON. REPLACED AFT AIRSTAIR EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA980931

1997

OTHER · 1997-12-18 Matched by certificate designator
ATA 5312

Part: BULKHEAD WEB — CORRODED (BS 178)

TUL - BS 178 WL 195-197, CORROSION ON BULKHEAD WEB ABOVE HORIZONTAL ANGLE. INSTALLED DOUBLER PER SRM 53-10-9. (M)

Source: SDR AALA972390
OTHER · 1997-12-14 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 600)

TUL - STATION 600, STRINGER 25L AND 24L, TOP FLANGE OF BELTFRAME DENTED, BULGING SIDE OF FRAME BETWEEN 24L AND 25L, DEEPLY DENTED OVER OUTBOARD EDGE OF 24L IN RADIUS OF BELTFRAME UPPER FLANGE. REMOVED DAMAGE PER SRM 51-40-3. FABRICATED DOUBLER AND INSTALLED PER SRM 51-40-1. (M)

Source: SDR AALA972385
OTHER · 1997-12-11 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 520)

TUL - FOUND STATIONS 520, STRINGER 25R TO 21R, BELT FRAME HAS NUMEROUS DEEP DENTS, CREASED INTO RADIUS. FABRICATED AND INSTALLED REPAIR ON FRAME PER SRM 51-40-3. (M)

Source: SDR AALA972387
OTHER · 1997-12-11 Matched by certificate designator
ATA 5314

Part: KEEL BEAM WEB — CRACKED (BS 870-874)

TUL - BS 870-874, RBL 6, WL 155-161, RIGHT KEEL BEAM WEB CRACKED AROUND NUMEROUS FASTENERS THROUGH 870 TO KEEL BEAM CHORD ANGLE REPAIR. REMOVED DOUBLER ON CHORD ANGLE FWD RIGHT SIDE OF APU AREA. MADE NEW DOUBLER INSTALLED WITH NEW FASTENERS PER SRM 51-40-4. INSTALLED WEB REPAIR PER SRM 51-40-2. (M)

Source: SDR AALA972388
OTHER · 1997-12-10 Matched by certificate designator
ATA 5311

Part: FRAME — CORROSION (BS 1130)

TUL - FOUND CORROSION AT SCREW HOLES AND LOWER FLOORBEAM LOWER CAP. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER PER SRM 51-10-6 AND ESO 11697, DATED 11/11/97. (M)

Source: SDR AALA972375
OTHER · 1997-12-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 520)

TUL - STATION 520, STRINGER 23L, BELTFRAME DEEPLY DENTED. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-3. (M)

Source: SDR AALA972389
OTHER · 1997-12-06 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 580)

TUL - STATION 580, STRINGER 25L TO 23L, BELTFRAME UPPER FLANGE DENTED, DENT AT 23L HAS CREASED RADIUS, DENT AT 25L HAS DENTED DOUBLER AT SPLICE. REMOVED DAMAGE PER SRM 51-40-3. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-3. (M)

Source: SDR AALA972386
OTHER · 1997-12-03 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 500)

TUL - STATION 500, BELT FRAME DENTED ABOVE PREVIOUS REPAIR, ABOVE STRINGER 22R. REMOVED PREVIOUS REPAIR, FABRICATED AND INSTALLED NEW DOUBLER PER SRM 51-40-3. (M)

Source: SDR AALA972289
OTHER · 1997-12-03 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 500)

TUL - STATION 500 STRINGER 21R TO 20R, BELTFRAME UPPER FLANGE DENTED WITH CREASE INTO RADIUS. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-3. (M)

Source: SDR AALA972288
OTHER · 1997-12-03 Matched by certificate designator
ATA 5313

Part: STRINGER — DENTED (BS 465)

TUL - FOUND STRINGER DENTED AT ATTACH POINT TO SKIN STATION 465 STRINGER 22L, DYE CHECKED FOUND TO BE CRACKED. CUT OUT DAMAGED SECTION OF STRINGER FABRICATED AND INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)

Source: SDR AALA972286
OTHER · 1997-12-03 Matched by certificate designator
ATA 5311

Part: FRAME — GOUGED (BS 783)

TUL - BELT FRAME STATION 783 DEEP TOOLING MARK BETWEEN STRINGERS 2 AND 3 RIGHT. INSTALLED DOUBLER ON BELTFRAME PER SRM 51-40-3. (M)

Source: SDR AALA972285
OTHER · 1997-12-03 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 660)

TUL - STATION 660, STRINGER 24R, BELTFRAME UPPER FLANGE DENTED, INCLUSIVE OF DEFORMATION TO VERTICLE FLANGE BEING BULGED BY DENT. REMOVED DAMAGED SECTION OF FRAME. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-3. (M)

Source: SDR AALA972287
OTHER · 1997-12-03 Matched by certificate designator
ATA 5713

Part: STRINGER — CRACKED (WS 656)

TUL - LEFT WING UPPER AFT STRINGER CRACKED AT JUNCTION WITH WS 656 RIB. STOP DRILLED AND INST REPAIR ANGLES PER SB 727-57A159 REV 5. (M)

Source: SDR AALA972290
OTHER · 1997-12-03 Matched by certificate designator
ATA 5320

Part: SPLICE — CRACKED (BS 438)

TUL - STRINGER SPLICE 21 RIGHT AT STATION 438 CRACKED. REPLACED STRINGER SPLICE PER SRM 53-30-3. (M)

Source: SDR AALA972284
OTHER · 1997-11-07 Matched by certificate designator
ATA 5311

Part: FRAME — DAMAGED (BS 700)

TUL - STATION 700, STRINGER 23R, PREVIOUS REPAIR ON BELTFRAME HAS SLOTS CUT TO FACILITATE BEND UP TO FIT FRAME, THERE IS ONLY ONE ROW OF FASTENERS ON OUTER SIDES OF SLOTS, 53-40-10. REMOVED DAMAGE ON BELTFRAME STATION 700 PER SRM 51-40-3. FABRICATED AND INSTALLED DOUBLER PER SRM 53-10-4. (M)

Source: SDR AALA972198
OTHER · 1997-11-07 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 700)

TUL - STATION 700, STRINGER 24R, BELTFRAME DENTED ON UPPER FLANGE, INTO RADIUS AND FORWARD FLANGE. REMOVED DAMAGE OF BELTFRAME STATION 700 PER SRM 51-40-3, FABRICATED AND INSTALLED DOUBLER STATION 700 STRINGER 24R PER SRM 53-10-4. (M)

Source: SDR AALA972199
OTHER · 1997-11-07 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 660)

TUL - STATION 660, STRINGER 24L TO 23L, BELTFRAME DENTED IN RADIUS, BOTH AREAS. REMOVED DAMAGE ON BELTFRAME PER SRM 51-40-3. FABRICATED AND INSTALLED DOUBLER PER SRM 57-40-3. (M)

Source: SDR AALA972195
OTHER · 1997-11-07 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 720)

TUL - STATION 720, STRINGER 246, BELTFRAME DENTED UPPER FLANGE. INSTALLED DOUBLER PER SRM 51-40-3. (M)

Source: SDR AALA972197
OTHER · 1997-11-06 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 560)

TUL - STATION 560, STRINGER 25L TO 23L, BELTFRAME HAS NUMEROUS DENTS IN UPPER FLANGE. REMOVED DAMAGE PER SRM 51-40-3, FABRICATED DOUBLER AND INSTALLED PER SRM 51-40-3. (M)

Source: SDR AALA972196
FALSE WARNING · 1997-08-21 Matched by certificate designator
ATA 2613

Part: DETECTOR — DEFECTIVE (NR 1 ENGINE)

MIA - FLT 2103 - AFTER TAKEOFF MIA DURING CLIMB-OUT, NR 1 ENGINE STRUT OVERHEAT INDICATION FLICKERED. ACCOMPLISHED ABNORMAL PROCEDURE AND PRECAUTIONARY SHUTDOWN NR 1 ENGINE. AIRCRAFT RETURNED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED NR 1 ENGINE STRUT OVERHEAT DETECTOR. ACCOMPLISHED GROUND ENGINE RUN WITH NO DEFECTS FOUND. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA971599
VIBRATION/BUFFET · 1997-04-06 Matched by certificate designator
ATA 2620

Part: WIRE — LOOSE (NR 2 SYSTEM)

DFW - FLT 0554 - AFTER TAKEOFF DFW DURING INITIAL CLIMB-OUT, LOUD VIBRATION OCCURRED ACCOMPANIED BY HIGH EGT AND DECREASING RPM IN NR 2 ENGINE. ACCOMPLISHED SHUT DOWN OF NR 2 ENGINE. BOTH FIRE BOTTLES WERE DISCHARGED FOR NR 2 ENGINE, HOWEVER, THE DISCHARGE LIGHTS DID NOT ILLUMINATE. AIRCRAFT DUMPED FUEL AND RETURNED TO DFW, LANDING WITHOUT INCIDENT. RE-SECURED LOOSE WIRE ON NR 2 FIRE EXTINGUISHER DISCHARGE SWITCH. ACCOMPLISHED SQUIB TEST WITH NO DEFECTS FOUND. SYSTEM GROUND CHECKED, NORMAL OPERATION. ALSO, REPLACED NR 2 ENGINE DUE TO TURBINE FAILURE. (X)

Source: SDR AALA970681
OTHER · 1997-03-07 Matched by certificate designator
ATA 5753

Part: FLAP TRACK — CORRODED (LT TE FLAP)

AFW - FOUND CORROSION AT MOUNT HOLES. REWORK WITHOUT CAD PLATE NICKLE STRIKE. REWORK MOUNT HOLES PER MRB 727-0030. (M)

Source: SDR AALA970508
OTHER · 1997-03-07 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (LT WING)

AFW - FOUND SKIN CORRODED AND MOUNT HOLE REAMED TO .783. REPAIR SKIN AND MOUNT HOLE PER MRB 727-0029. (M)

Source: SDR AALA970506
OTHER · 1997-03-05 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 708)

AFW - FOUND CORRODED STRINGER AT 26L STATION 708. INSTALLED REPAIR SECTION AS PER SRM 53-10-08. (M)

Source: SDR AALA970504
OTHER · 1997-03-05 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 484)

AFW - FOUND CORROSION IN STRINGER 28R AT STATION 484. REMOVED CORRODED SPLICE AND INSTALL SPLICE PER SRM 53-10-3. (M)

Source: SDR AALA970502
OTHER · 1997-03-05 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 720)

AFW - FOUND SHEAR TIE CORRODED. REINSTALLED NEW SHEAR TIE USING SAME FASTENER LOCATIONS AS ORIGINAL PER SRM CHAP 51. (M)

Source: SDR AALA970500
OTHER · 1997-01-02 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (BS 825)

TUL - FOUND STUB FRAME CRACKED THROUGH HOLE, STATION 825. INSTALLED DOUBLER PER SRM 51-40-2 FIG 1A, PAGE 6B. (M)

Source: SDR AALA970007