Accident & incident history

HILLER ACFT UH-12B No injuries Part 91 — operator not named in the NTSB record
Source: NTSB case LAX74DUJ24

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

2 reports on file, 2024-11-08 – 2026-09-15.

OTHER · 2026-09-15 Unresolved
ATA 2434

Part: BOLT — UNSECURE (ALTERNATOR) · airframe 6,486 hrs

DURING AN ANNUAL INSPECTION THE ALTERNATOR WAS FOUND TO BE LOOSE BUT STILL WEDGED IN THE MOUNT, AND THE FAN BLADES RUBBING ON THE ENGINE/ALTERNATOR MOUNT. THE ALTERNATOR MOUNTING BOLT WAS FOUND IN THE LOWER COWLING, THE NUT AND WASHER WERE NOT FOUND. IT IS BELIEVED THAT THE NUT VIBRATED LOOSED DURING OPERATION, ALLOWING THE BOLT TO WORK ITS WAY FREE. THE ALTERNATOR AND THE MOUNT WERE BOTH DAMAGED AND REPLACED.

Source: SDR 9WQR202609170736
WARNING INDICATION · 2024-11-08 Matched by certificate designator
ATA 2800

Part: CONTROL PANEL — FAULTY (E/E BAY) · airframe 6,038 hrs · 2,138 cycles

ENG 1 FWD-ENG 2 AFT CENTER LEFT LOW PRESS C/B'S POPPED ON P91 PNL...115V AC BUS1 SEC2. IS IN HGR TECH SUPPORT OFFICE CREW DEBRIEF. DURING CLIMB ALT IN TEENS MSTR CAUTION AND FUEL CONTINUED, CHKD P91 F5 XFER BUS 1 SEC2 C/B WAS NOT POPPED. WHILE CHECKING VOLTAGE AT C827, C828, & C845, FOUND "C" PHASE AT REF. WDM 24-51-11-1 SUGGEST CHECK C3002 CB FOR 115VAC AT A2,B2, NOTE: C2 PHASE ALSO POWERS RT SIDE WINDOW HEAT. AT CONNECTOR D11414J FOUND 16.95 VAC AT PIN C & ANNUNCIATED WITH ASSOC. LT FWD, RT AFT & LT CTR B/P LOW PRESS GFI'S NOT TRIPPED. NOTICED BPCU FAULT LIGHT ON. NEEDS FURTHER "0" VOLTS, "A" & "B" PHASE HAD 115 VAC. C2. 24-51-14-1. 115 VAC AT PINS A & B. REMOVED P91 PANEL REF AMM LIGHTS. NO OTHER ABNORMALITIES NOTED. REF SSM 28-23-11-101, T/S. IF NEEDED P/N 762187G, 42-2441-9-0003 NIS LAX. BITE OF ELEC 24-21-21-000-801, FOUND XFR BUS 1 SEC 2 C.B. C3002 INTERNALLY 24-51-11-101. FOUND D1 D3 D5 BOOST PUMPS 1FWD, 2AFT AND CTR LT PNL ON OVERHEAD, NO FAULTS RECORDED. BAD. NEW P91 PANEL M& E REMOVED P91 PNL IDT FOR P91 PANEL FEED CABLE INSTALLATION VERIFIED , R/R P91 POWER DISTRIBUTION PANEL REF AMM 24-21-21/401. REQUIRES PERFORMED OPS CHECK OF ALL FUEL PUMPS. LOW PRESS LIGHT OPS CHK.

Source: SDR CALA2024111102828