26 reports on file, 1995-03-09 – 2001-06-13.

SMOKE/FUMES/ODORS/SPARKS; OVER TEMP · 2001-06-13 Matched by certificate designator
ATA 2120

Part: DUCT — SEPARATED (A/C BAY) · airframe 62,827 hrs · 28,570 cycles

ON APPROACH AFTER GEAR DOWN APPROX 1300 FT, LOUD BANG FOLLOWED BY AIR CONDITIONING SMOKE ON TOUCHDOWN AND B-AREA OVERHEAT. FOUND INLET DUCT GOING TO NR 2 ACM SEPARATED WILL NEED DUCT, GASKETS, AND HARDWARE. LOCKED OUT NR 2 PACK FLOW CONTROL VALVE PER MEL 21-21-01B.

Source: SDR DLL10010959
SMOKE/FUMES/ODORS/SPARKS · 2001-06-13 Matched by certificate designator
ATA 2120

Part: SMOKE — DETECTED (CABIN) · airframe 62,827 hrs · 28,570 cycles

ON LANDING F/A REPORTED SMOKE IN THE CABIN. MTC IN PROGRESS. TROUBLESHOOTING CAUSE OF SMOKE.

Source: SDR DLL10010961
OTHER · 2001-06-10 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — LOW (CABIN) · airframe 62,814 hrs · 28,561 cycles

TRACK LIGHTING INOP IN E ZONE-REPLACED POWER SUPPLY

Source: SDR DLL10010943
NO TEST · 2001-06-10 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (EXTERIOR) · airframe 62,814 hrs · 28,561 cycles

R4 EXTERIOR EMERGENCY LIGHT INOP. RELAMPED LIGHT.

Source: SDR DLL10010942
NO TEST · 2001-04-27 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (CABIN) · airframe 62,570 hrs · 28,395 cycles

R2 SLIDE LIGHT INOP. REPLACED CHARGER UNIT.

Source: SDR DLL10010679
SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 2001-04-18 Matched by certificate designator
ATA 2120

Part: DUCT — CRACKED (AC BAY) · airframe 62,519 hrs · 28,360 cycles

OVERHEAT ON NR 2 PACK FLOW CONTROL COMPRESSOR DISCHARGE 320 DEG. CENT. THERE WAS A POPPING NOISE AND SOME SMOKE IN CABIN JUST BEFORE THE OVERHEAT. FOUND NR 2 PACK COMPRESSOR DISCHARGE DUCT CRACKED AND WATER SEPARATOR CAP BLOWN ALSO DISCHARGE SENSOR WIRES BROKE. REMOVED WATER SEP. CAP AND CAPPED AND STOWED WIRES AND LOCKED NR 2 PACK VALVE CLOSED. FWD TO MCO PLAC PER MEL 21-21-01B

Source: SDR DLL10010639
SMOKE/FUMES/ODORS/SPARKS · 2001-03-11 Matched by certificate designator
ATA 2530

Part: OVEN — OVERHEATED (GALLEY) · airframe 62,245 hrs · 28,226 cycles

TWO PBES USED DUE SMOKE FROM OVERTEMP OVENS IN LOWER GALLEY- PLS REPLACE PBES ATL MAINT F/A TOOK 2 CABIN PBES TO LOWER GALLEY PLS CHECK ALL PBES FOR PROPER LOCATION. CA-AS PER F/A VERBAL OVENS ON FOR EXTENDED PERIOD DUE TO FROZEN MEALS. INSPECTED OVENS FOUND 6 OVERHEAT WD TRAPPED. RESET SAME OPS CKD OVEN. CKS OK. REPLACD PBE KITS.

Source: SDR DLL10010397
Earlier reports · 1995–2000 · 19 reports

2000

SMOKE/FUMES/ODORS/SPARKS · 2000-09-24 Matched by certificate designator
ATA 2530

Part: OVEN — SMOKE (GALLEY) · airframe 60,966 hrs · 27,782 cycles

HALON EXTINGUISHER DISCHARGED INTO OVEN TO COMBAT SMOKE FROM GREASE. PER FLIGHT ATTEND, GREASE SMOKE FROM NR 2 OVEN. REPLACED NR 2 OVEN AND HALON EXTINGUISHER. CLEANED ALL OVENS IN GALLEY AND OPERATIONAL CHECKED NORMAL ALL OVENS.

Source: SDR DLL10001854
OTHER · 2000-09-07 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (RT WING) · airframe 60,832 hrs · 27,738 cycles

THE LOWER SKIN OF THE RT WING WAS FOUND WITH A .5 INCH CRACK AT THE RUNOUT OF STRINGER 19 AT IWS 600. THE CRACKED AREA OF SKIN WAS CUTOUT TO REMOVE THE CRACK. THE CUTOUT WAS REPAIRED WITH 3 ALUMINUM EXTERNAL DOUBLERS PER ER/A 378415-14, REV A.

Source: SDR DLL10001736
OTHER · 2000-09-06 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE) · airframe 60,832 hrs · 27,738 cycles

THE FUSELAGE SKIN WAS FOUND CORRODED BETWEEN FS 1523 & 1545 AND BETWEEN STRINGERS 33 & 35. THE CORROSION WAS REMOVED WITH A 9.1 X 5.6 INCH CUTOUT. THE CUTOUT WAS REPAIRED WITH AND EXTERNAL ALUMINUM DOUBLER AND TRIPLER INSTALLED PER ER/A378437-14.

Source: SDR DLL10001721
FLAME/FIRE · 2000-05-25 Matched by certificate designator
ATA 7200

Part: ENGINE — FIRE (NR 2) · airframe 59,886 hrs · 27,423 cycles

NR 2 ENG ROLLED BACK AFTER START. MAINT INSP TAILPIPE AND MADE NORMAL RESTART. REPORT BY TWR THAT A/C HAD FLAME FROM NR 2 ENG ON PUSHBACK. CREW REPORTED ENG DID NOT EXCEED 500 EGT. A/C WAS TAILED INTO WIND. ENGINE SPUN TO EXTINGUISH FIRE.

Source: SDR DLL10001027

1999

WARNING INDICATION · 1999-12-09 Matched by certificate designator
ATA 7200

Part: ENGINE — MALFUNCTIONED (NR 2)

STEADY FILTER PRESSURE LIGHT NR 2 ENGINE, LEVEL AT 11,000 FT 250 KTS. POWER UP ON ENGINES, LIGHT WENT OUT WHEN ENGINE PULLED TO IDLE. ENGINE SHUTDOWN. CHECKD FILTER AND CHIP DETECTORS, NO PROBLEMS NOTED. REPLACED DIFF PRESSURE SWITCH.

Source: SDR DLL10992696
FLT CONT AFFECTED; WARNING INDICATION · 1999-12-02 Matched by certificate designator
ATA 2780

Part: LE FLAP — MALFUNCTIONED (WINGS)

FLAP/SLAT LOCK LIGHT ILLUMINATED IMMEDIATELY AFTER TAKEOFF. PRIOR TO FLAP RETRACTION FLAPS RETRACTED OK BUT SLATS STAYED AT FULL DOWN AND LOCKED. REPLACED LT SLAT BRAKE, CHECKS GOOD PER MM. WHEN THE STROBE LIGHT SWITCH WAS TURNED ON, ALL 3 SLAT COMPARTOR LIGHTS FLASH AND FLAP/SLAT LOCK ANNUN. ALSO, FAINT CRACKING SOUND WAS HEARD ON SER INTERPHNE. REPLACED STROBE FLASHER AND ALL OK.

Source: SDR DLL10992798
FLT CONT AFFECTED; WARNING INDICATION · 1999-11-27 Matched by certificate designator
ATA 2780

Part: COMPARATOR — MALFUNCTIONED (LE FLAP)

AFTER TAKEOFF, FLAP/SLAT LIGHT ILLUMINATED ON S/O PANEL. FLAPS CAME UP RETRACTED BUT SLATS LOCKED IN EXTENDED POSITION. FOUND BOTH ASYMMETRY BRAKES TRIPPED. RESET LT AND RT BRAKES. REPLACED L/E ASYMMETRY COMPARATOR. FLAP/SLAT OPN NORMAL.

Source: SDR DLL10992613
SMOKE/FUMES/ODORS/SPARKS · 1999-05-17 Matched by certificate designator
ATA 3320

Part: BALLAST — FAILED (ROW 5E)

F/A'S REPORTED SMOKE IN THE CABIN IN THE VICINITY OF SEAT 5E, BELIEVED TO BE COMING FROM LIGHTING BALLAST. DEACTIVATED SYSTEM, CONDITION IMPROVED. REPLACED OVERHEAD MODULE AT SEAT 5E/F, REACTIVATED LIGHTING SYS AND ALL CK NORMAL.

Source: SDR DLL10991085

1997

OTHER · 1997-10-08 Matched by certificate designator
ATA 5312

Part: BULKHEAD WEB — CRACKED (BS 328)

THE BULKHEAD STIFFENER PANEL AT FS 328, RBL 22 WAS FOUND CRACKED AT THE END OF THE FOURTH MILLED STIFFENER FROM THE BOTTOM. CRACK TRIMMED OUT WITH A 1 BY 0.5 TRIM OUT. REPAIRED PER ERA 330780-14.

Source: SDR DLL10972037
OTHER · 1997-10-08 Matched by certificate designator
ATA 5312

Part: BULKHEAD WEB — CORRODED (BS 328)

FS 328 BULKHEAD WEB AT LBL 90 WAS FOUND TO HAVE CORROSION. CORROSION WAS CUTOUT. WEB WAS REPAIRED PER ERA 330749-14.

Source: SDR DLL10972028
OTHER · 1997-09-22 Matched by certificate designator
ATA 5312

Part: WEB — CORROSION (NLG WW)

THE LBL 22 WEB JUST AFT OF THE FWD NLG DOOR HINGE CUTOUT WAS FOUND CORRODED. A SECTION OF THE WEB MEASURING 8 BY 12 WAS CUT OUT. THE WEB IS MADE FROM TWO BONDED SHEETS OF 7075-T6 CLAD MATERIAL, ONE MEASURING .071 THK AND THE OTHER .025 THK. INSTALLED DOUBLER.

Source: SDR DLL10971923
OTHER · 1997-06-30 Matched by certificate designator
ATA 5711

Part: SPAR CAP — CRACKED (BS 1103)

THE CENTER WING INTERMEDIATE SPAR UPPER CAP LOCATED AT STA 1103 WAS FOUND TO HAVE A CRACK 2.3437 ON THE RT OUTBOARD SIDE. THE CRACK IS TYPICAL OF THOSE DESCRIBED IN S/B 093-57-087, BUT IS BEYOND THE ALLOWABLE LIMITS. DURING THE INSTALLATION OF THE REPAIR, TWO FASTENERS HAD SHORT EDGE DISTANCE. THIS IS A PRE-EXISTING CONDITION FROM THE MANUFACTURER. THIS REPAIR INSTALLED AT THIS LOACTION WAS APPROVED PER FAA/ DER FORM 8110-3, DER DESIGNATION SO-775, DTD 6-30-97.

Source: SDR DLL10971334
OTHER · 1997-06-27 Matched by certificate designator
ATA 5320

Part: SIDEWALL — CRACKED (BS 349)

THE NLG WHEEL WELL SIDEWALL BULKHEAD UPPER CAP AT LBL 22.5 WAS FOUND CRACKED ON THE I/B SIDE OF THE HORIZONTAL FLANGE AT STA 349. THE CRACK RUNS FORWARD APPROX 2 INCHES. THE CRACK WAS TRIMMED OUT AND A REPAIR ANGLE WAS INSTALLED AND APPROVED PER FAA/DER FORM 8110-3, DER DESIGNATION SO-775, DTD 6-27-97.

Source: SDR DLL10971335
NO TEST · 1997-04-05 Matched by certificate designator
ATA 3350

Part: POWER PACK — INOPERATIVE (CABIN)

A AND B ZONE EMER TRACK LIGHTING INOP. REPLACED FWD RT BATT POWR PAK, CK OK.

Source: SDR DLL10970615

1996

SMOKE/FUMES/ODORS/SPARKS · 1996-10-03 Matched by certificate designator
ATA 2150

Part: ACM — SEIZED (FUSELAGE)

DURING TAXI OUT, THERE WAS A LOUD BANG FROM UNDER AREA NEAR 2R DOOR. SHORTLY AFTER AFT PART OF CABIN BEGAN TO FILL WITH SMOKE. ALL PACKS AND ENG BLEEDS SHUT OFF AND SMOKE STOPPED. FOUND ACM SEIZED, REPLACED ACM.

Source: SDR DLL10962221
OTHER · 1996-02-06 Matched by certificate designator
ATA 5312

Part: BLKHD WEB — CRACKED (FS 1212)

WHILE PERFORMING INSPECTIONS PER SI 7-70645-12, THE FS 1212 CANTED BULKHEAD WAS FOUND WITH CRACKS IN THE TYPICAL LOCATION AT LBL 30, LBL 10, RBL 22.5 AND RBL 42.5. THE SUBJECT WEB IS M/F FROM .050 7075-T6 SHEET AND WILL BE REPAIRED PER DL ERA 273246 REV A.

Source: SDR DLL10960276

1995

OTHER · 1995-08-25 Matched by certificate designator
ATA 5312

Part: FITTING — CRACKED (AFT P-DOME)

COMPLYING WITH INSPECTION SI 7-66332-12 AND AD T95-18-52, FOUND STRINGER TO AFT P-DOME SPLICE FITTINGS CRACKED AT STRINGERS NR 5 AND NR 58. FITTINGS SCHEDULED FOR REPLACEMENT PER DL ERA 272720-14.

Source: SDR DLL10953647
NO TEST · 1995-08-03 Matched by certificate designator
ATA 3350

Part: EEL BATTERY PACK — DISCHARGED (CABIN)

ON LAYOVER, D-SECTION EMERGENCY TRACK LIGHTING INOP. REPLACED BATTERY PACK, OPERATION NORMAL.

Source: SDR DLL10953285
OTHER · 1995-03-09 Matched by certificate designator
ATA 5720

Part: ANGLE — CRACKED (LT WING)

LEFT T/E BAT STRUCTURE LWR CAP AT ITES 275.00 APPROX 13 INCHES OUTBD OF OUTBD HINGE FITTING NBR 2 SPOILER LWR CAP HAS A 2 INCH CRACK GOING THROUGH FASTENER HOLE.

Source: SDR DLL10950993