N74007
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
101 reports on file, 2003-03-14 – 2026-10-28.
Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 125,945 hrs · 12,941 cycles
EMERGENCY LIGHTS IN THE REAR CABIN WERE INOPERATIVE. T/S AND RESET EMERGENCY LIGHTS. OPS CHKD GOOD IAW FIM-33-51, TASK 806.
Part: SWITCH — MALFUNCTIONED (ZONE 200) · airframe 125,603 hrs · 12,906 cycles
ROW 53 EMG EXIT LIGHTS ILLUMINATED IN ARMED POSITION RESET LIGHT SWITCH AND FOUND NORMAL OPS.
Part: OVEN — CONTAMINATED (ZONE 900) · airframe 124,582 hrs · 12,804 cycles
CONTAINED PASTA FIRE IN OVEN 109 FRONT GALLEY REF AMM 05-51-58-800-801-C3 AND GMM 04-20-16. REMOVED OVEN AND INSPECTED EXTERIOR OF OVEN, GALLEY INTERIOR OVEN CAVITY, WIRE HARNESS, POWER POINT PLUGS & FOUND NO FIRE, HEAT OR SMOKE DAMAGE. REPLACED OVEN AT POSITION 109. IAW MM 25-32-02.
Part: BATTERY — NO TEST (ZONE 200) · airframe 122,827 hrs · 12,618 cycles
CABIN OVERHEAD EMERGENCY LIGHT BATTERY PACK (M33094) CAPACITY CHECK FAILED. THE BATTERY PACK (M33094) WAS REPLACED & TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 122,827 hrs · 12,618 cycles
R2 DOOR EMERGENCY LIGHT BATTERY TEST FAILED. BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 122,827 hrs · 12,618 cycles
CABIN OVERHEAD L1 DOOR EMERGENCY LIGHT BATTERY PACK, CAPACITY CHK FAILED. THE BATTERY PACK (M33093) WAS REPLACED & TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 122,827 hrs · 12,618 cycles
CABIN OVERHEAD EMERGENCY LIGHT BATTERY PACK (M33096) CAPACITY CHECK FAILED. THE BATTERY PACK (M33096) WAS REPLACED & TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — INOPERATIVE (R4 EPAS) · airframe 122,609 hrs · 12,598 cycles
DOOR 4R EPAS BATTERY PACK ASSY. INOPERATIVE WHEN REINSTALLING IAW WORK CARD 26-5211-9-9003. REMOVED AND REPLACED DOOR 4R EPAS BATTERY PACK IAW AMM 52-11-20. OPS TESTED OK.
Earlier reports · 2003–2025 · 93 reports
2025
Part: SKIN — DAMAGED (ZONE 100) · airframe 121,963 hrs · 12,531 cycles
LIGHTNING STRIKE DAMAGE AT STA 845 AND BETWEEN S-27 - S-28 BETWEEN S-28 AND S-29 ACPD CONDUCTIVITY CHECK ON HEAT DAMAGED AREA. FOUND DAMAGE AREA AVERAGE READING OF 45. READING OF 38 AT POINT OF IMPACT. REMOVED THE EXISTING FASTNERS AND CUT OUT DAMAGED PART OF SKIN IAW SRM 53-00-01-2R-4. ACP HFEC 777 NTM PART 6 51-00-01 PROCEDURE 2. NO CRACKS. ACP HFEC ROTO PBOBE 777 NTM PART 6 51-00-02 PROCEDURE 2. NO CRACKS AT HOLES. MANIFACTURED FILLER. INSTALLED FILLER WASHERS TO THE INITIAL FASTENER LOCATIONS IN REF TO SRM 53-00-01-2R-4 REPAIR 4. INSPECTED REPAIR REF SRM 53-00-01-2R-4. 100% GOOD. COMPLETED INSTALLING REPAIR DOUBLER IAW SRM 53-00-01-2R-4 REPAIR 4. APPLIED FILLET SEAL, PRIMED & PAINTED SURFACE. APPLIED CORROSION INHIBITING COMPOUND REF SRM 53-00-01-2R-4 REPAIR 4.
Part: FAN — SEIZED (ZONE 100) · airframe 121,741 hrs · 12,511 cycles
PER VERBAL FROM THE CAPTAIN, ELECTRICAL, ACRID ODOR IN CABIN AND FLT DECK. NO VISIBLE SMOKE NOTED. CONDITIONAL INSPECTION CARRIED OUT IAW AMM 05-51-58-800-801-C3, UP TO & INCLUDING BLOCK 1. B. NO DEFECTS NOTED BY CREW IN DE-BRIEFING, RECIRC FAN STATUS MESSAGE SHOWS ON MAT AS FIRST MESSAGE TO APPEAR DURING FLT. MESSAGE 21-24700 ACTIVE. OTHER MESSAGES OCCURRED AFTERWARDS & ARE EXPECTED TO BE A CONSEQUENCE OF HOW THE ACFT WAS CONFIGURED FOR THE FUME EVENT. INSPECTIONS CARRIED OUT IAW AMM 05-51-58-800-801-C3 OF FLT DECK, GALLEYS, LAVS, CABIN, EE BAY WITH NO ODORS EVIDENT. RIGHT LOWER RECIRC FAN REMOVED IAW AMM REF 21-25-07 AND FOUND SEIZED. CONDITIONAL INSPECTION IS NOW COMPLETE.
Part: BATTERY PACK — FAULTED (ZONE 200) · airframe 120,598 hrs · 12,394 cycles
EVAC LIGHTS ON IN ECON CABIN REPLACED BATTERY PACK AT DOORS 4L. R& R, PACKS M33407, M33408 & M33409 REF MM 33-51-06-960-802, ALL EXIT LIGHTS CK OK.
Part: OVEN — ODOR (ZONE 900) · airframe 119,330 hrs · 12,257 cycles
CHILLER 208 FWD GALLEY HAD ELECTRICAL ODOR THEN SHUT DOWN.ODOR S TOPPED SDR HAS BEEN FLAGGED PER GMM 04-20-16 3B (5) ACCOMPLISHED CONDITIONAL INSPECTION REF. AMM. TASK 05-51-58-800-801-C3. ABLE TO VERIFY THAT ELECTRICAL ODOR COMING OUT OF OVEN #108. G11. PLACING ITEM ON MEL. DEFER OVEN 108 INOP COMPLIED WITH MEL.
2024
Part: SKIN — DAMAGED (ZONE 100) · airframe 117,069 hrs · 12,025 cycles
FWD CARGO DOOR EDGE DAMAGE. DAMAGE IS ON THE OUTER SKIN AND SEAL RETAINER. ALSO THERE IS NO DAMAGED AREA, INTERIM REPAIRED, SEALED AND TAPED WITH ALUMINUM WITHIN #1 FLIGHT CYCLE. DAMAGE ON THE DOOR STRUCTURE. FOIL. LEAK TEST PASSED. SEAL DEPRESSOR WAS NOT DAMAGE OR TORN, NO CRACK INDICATIONS FOUND AT THIS TIME. REMOVED ALL DAMAGE AND ADJACENT FASTENERS PER AVO13813 PROVIDED ESC WITH DIMENSION OF ALL DAMAGE REMOVED. C/W STEPS 3 & 4 OF AVO:13813- FOR H.F.E.C. OF DAMAGE TRIM OUT INSTRUCTIONS 1 AND 2. EDGES OF FWD CARGO DOOR SKIN PER 777 NDT PART 6 -51-00-01 PROC 22. REPAIR DOUBLER. COMPLETED STEPS 7 AND 8 AND NO ADDITIONAL MATERIAL WAS REMOVED.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN L3 DOOR OVERHEAD PANEL EMER LT BATT (M33400) CAPACITY CHECK FAIL. CABIN L3 DOOR OVERHEAD PANEL EMER LT BATT (M33400) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - DOOR L1 OVERHEAD PANEL EMER LT BATT CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614510 AND ORIGINATED BY EMP V920591. DOOR L1 OVERHEAD PANEL EMER LT BATT REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN R2 DOOR OVERHEAD PANEL EMER LT BATT (M33097) CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614491 AND ORIGINATED BY EMP V920591. CABIN R2 DOOR OVERHEAD PANEL EMER LT BATT (M33097) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN L2 DOOR OVERHEAD PANEL EMER LT BATT (M33099) CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614448 AND ORIGINATED BY V920591. CABIN L2 DOOR OVERHEAD PANEL EMER LT BATT (M33099) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN R2 DOOR OVERHEAD PANEL EMER LT BATT (M33098) CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614490 AND ORIGINATED BY EMP V920591. CABIN R2 DOOR OVERHEAD PANEL EMER LT BATT (M33098) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN R3 DOOR OVERHEAD PANEL EMER LT BATT (M33404) CAPACITY CHECK FAIL. CABIN R3 DOOR OVERHEAD PANEL EMER LT BATT (M33404) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN R1 DOOR OVERHEAD PANEL EMER LT BATT (M33094) CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614492 AND ORIGINATED BY EMP V920591. CABIN R1 DOOR OVERHEAD PANEL EMER LT BATT (M33094) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN L2 DOOR OVERHEAD PANEL EMER LT BATT (M33096) CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614489 AND ORIGINATED BY EMP V920591. CABIN L2 DOOR OVERHEAD PANEL EMER LT BATT (M33096) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN R4 DOOR OVERHEAD PANEL EMER LT BATT (M33409) CAPACITY CHECK FAIL. CABIN R4 DOOR OVERHEAD PANEL EMER LT BATT (M33409) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN R3 DOOR OVERHEAD PANEL EMER LT BATT (M33401) CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614481 AND ORIGINATED BY EMP V920591. CABIN R3 DOOR OVERHEAD PANEL EMER LT BATT (M33401) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (M33407) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - CABIN L4 DOOR OVERHEAD PANEL EMER LT BATT (M33407) CAPACITY CHECK FAIL. CABIN L4 DOOR OVERHEAD PANEL EMER LT BATT (M33407) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
SUPPORT TASK - CABIN L3 DOOR OVERHEAD PANEL EMER LT BATT (M33405) OP CHECK FAIL. CABIN L3 DOOR OVERHEAD PANEL EMER LT BATT (M33405) REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: BATTERY — NO TEST (ZONE 200) · airframe 115,727 hrs · 11,884 cycles
B777-33-3-7015 - OHAR EMER LT BATTERY CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.3614505. EMER LT BATTERY REPLACED AND TEST NORMAL AS PER AMM 33-51-06.
Part: OVEN — ODOR (AFT GALLEY) · airframe 113,271 hrs · 11,612 cycles
BURNING PLASTIC OR RUBBER ODOR IN AFT GALY. SMELL STOPD AFT OVN N CH LR OFF CHECKED AFT GALLEY CHILLERS AND OVENS. NO DEFECTS NOTED. UNABLE TO DUPLICATE DEFECT.
2022
Part: HYDRAULIC SYSTEM — WARNING MESSAGE (L HYD SYS RES) · airframe 108,316 hrs · 11,043 cycles
HYD QTY LOW L EICAS ADVISORY LEFT HYDRAULIC SYSTEM RESERVOIR QUANTITY LOW. QTY < .40 FIM TASK REF : 29-11 TASK 813 CMC MSG# 2910340 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: HYDRAULIC INTERFACE MOD ULE (HYDIM)(L) CMC MSG# 2910340 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: 14QTS HYDRAULIC REFILLED ACC AMM 12-12-01-610-803 REV96. TROUBLESHOOTING AND FINDINGS UNDER LOG 3289251
Part: CHARGER — NONE (DOOR R2) · airframe 107,388 hrs · 10,937 cycles
SUPPORT TASK - R2 DOOR EXIT LIGHT AND MIDDLE ZONE RH OVERHEAD EMERGENCY LIGHT FOUND DIM SHORT TIME WHEN EMERGENCY LIGHT TEST TRANSFER REF HXWO 1061171 AND ORIGINATED BY EMP V896965 R2 DOOR OVERHEAD EMERGENCY LIGHT CHARGER REPLACED AND LIGHTING CHECK NORMAL AS PER AMM33-51-00 WORK ACCOMPLISHED BY MECHANIC V896965 INSPECTED BY V926996 IDT INSPECTED BY HX107723 ADD EMP:V907050
Part: CHARGER — NONE (DOOR R4) · airframe 107,388 hrs · 10,937 cycles
SUPPORT TASK: AFT ZONE L/H AND R/H EMERGENCY LIGHT FOUND DIM SHORT TIME TRANFER REF HXWO 1055679 AND ORIGINATED BY EMP V896965 R4 DOOR OVERHEAD EMERGENCY LIGHT CHARGER REPLACED AND LIGHTING CHECK NORMAL AS PER AMM 33-51-00 WORK ACCOMPLISHED BY MECHANIC V896965 INSPECTED BY V926996 IDT INSPECTED BY HX107723 ADD EMP:V907050
Part: NONE — NONE (RH BS 2370) · airframe 107,388 hrs · 10,937 cycles
AD2022-06-07 SUPPORT TASK EA 5380-01113 OP 018 RH BS 2370 PVIOT BULKHEAD FORWARD CHROD CRACK FOUND AS MARKED. PLEASE GENERATE EA 5380-01113 REV B OP 26 TRANSFER REF NR HX WO.1013732 AND ORIGINATED BY EMP V896827. RH BS 2370 PIVOT BULKHEAD FORWARD CHORD REPLACEMENT AS PER EA 5380-01113 REV B OP 026 WORK ACCOMPLISHED BY MECHANIC V897545 INSPECTED BY V934412 RII INSPECTED BY HX329567
Part: NONE — CRACKED (L BS 2370 PIVOT) · airframe 107,388 hrs · 10,937 cycles
AD 2022-06-07 SUPPORT TASK - EA 5380-01113 OP 17 LH BS 2370 PIVOT BULKHEAD FORWARD CHORD CRACK FOUND AS MARKED. PLEASE GENERATE EA 5380-01113 REV B OP 25 TRANSFER REF NR HX WO.1013720 AND ORIGINATED BY EMP V896827. LH BS2370 PIVOT BULKHEAD FORWARD CHORD REPLACEMENT AS PER EA5380-01113 REV B OP 025 , WORK ACCOMPLISHED BY MECHANIC V897545 INSPECTED BY V934412 RII INSPECTED BY HX147141 ADD EMP:V896853
Part: BATTERY — NONE (M9-73) · airframe 107,388 hrs · 10,937 cycles
SUPPORT TASK - OVERHEAD ATTENDANT REST EMERGENCY LIGHT (M9073) FOUND INOP TRANSFER REF HXWO 1045546 AND ORIGINATED BY EMP V896965 OHAR EMER LT BATTERY REPLACED AND OP TEST RESULT NORMAL AS PER AMM 33-51-05 WORK ACCOMPLISHED BY MECHANIC V907894 INSPECTED BY V926996 IDT INSPECTED BY HX107723 ADD EMP:V907050
Part: NONE — NONE (M33093) · airframe 107,388 hrs · 10,937 cycles
B777-25-3-7170 L1 DOOR M33093 EMER BATTERY PACK FOUND BATTERY "LOW" TRANSFER REF HXWO 1018087 AND ORIGINATED BY EMP V896975 L1 DOOR M33093 EMER BATTERY PACK AND POWER SUPPLY REPLACED AS PER AMM33-51-06 AND OP TEST CARRIED OUT RESULT NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V896975 INSPECTED BY V926996 IDT INSPECTED BY HX107723 ADD EMP:V907050
Part: NONE — NONE (M33400) · airframe 107,388 hrs · 10,937 cycles
B777-25-3-7170 L3 DOOR M33400 EMER BATTERY PACK FOUND BATTERY "LOW" TRANSFER REF HXWO 1018086 AND ORIGINATED BY EMP V896975 L3 DOOR M33400 EMER BATTERY PACK AND POWER SUPPLY REPLACED AS PER AMM 33-51-06 AND OP TEST CARRIED OUT RESULT NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V896975 INSPECTED BY V926996 IDT INSPECTED BY HX107723 ADD EMP:V907050
Part: BATTERY — NONE (M33406) · airframe 107,388 hrs · 10,937 cycles
B777-25-3-7170 L3 DOOR M33406 EMER BATTERY PACK FOUND BATTERY "LOW" TRANSFER REF HXWO 1015854 AND ORIGINATED BY EMP V896975 L3 DOOR M33406 EMER BATTERY PACK REPLACED AND OP TEST CARRIED OUT WITH NORMAL IAW AMM 33-51-06 WORK ACCOMPLISHED BY MECHANIC V896975 INSPECTED BY V926996 IDT INSPECTED BY HX107723 ADD EMP:V907050
Part: MODULE — DAMAGED (2 LH DOOR) · airframe 106,417 hrs · 10,819 cycles
CEILING ASSY-CROSS AISLE MASTER CALL OUT MODULE DOOR 2LH DAMAGED MODULE CALL LIGHT PANEL TEMPORARILY REPAIRED, ALL FUNCTIONS OK DEFERRED IAW EC/RA #3351X01371 DOCUMENT NORMAL DEFERRED IAW MEL REF 2342BC THIS REPAIRE REQUIRES RECHK BEFORE EA FLIGHT AND REPAIRED WITHIN TOMC-APPROVAL FROM SC1ELBYC COMMENT 3 FLIGHT CYCLES PER ECRA 3351-01371...TOMC MO MEL 2342BC WRONG REF SEE PICTURE ATTACHED SEE PICTURE ATTACHED SEE PICTURE ATTACHED SEE PICTURE ATTACHED SEE PICTURE ATTACHED SEE PICTURE ATTACHED TOMC APPROVED : QC REVIEWED. RECORDS UPDATE RECORED UPDATE REF MM33-51-01-960-802, REPLACED SIGN ASSY. EMERGENCY EXIT SIGN AND MASTER CALL LIGHTS OPS CK OK. TOMC APPROVED : QC REVIEWED. T/A: 3 FC...SN TOMCQC REV PERFORMED
Part: BATTERY — DISCHARGED (APU BATTERY) · airframe 106,083 hrs · 10,771 cycles
MAIN BATTERY IS DISCHARGING AFTER ENGINE START SWAPPED A/C MAIN BATTERY AND BATTERY CHARGER WITH APU BATTERY 24-31-06. APU BATTERY CHARGER CONSIDERED INOP. C/W MEL 2431D. APU BATT CHARGER DEFERRED PER MEL 2431D, M-PROCEDURE PERFORMED, AND BATTERY CHARGER PER AMM 24-31-01, 24-31-05, 24-31-02, PLACARD INSTALLED. DISPATCH DESK: 61 NAME: DAVE DATE: 19-APR-22- NOC DESK: 777 NAME: D.B DATE: 19-APR-22- SWAPPED MAIN BATT CHARGER & MAIN BATT WITH APU BATT CHARGER & APU BATT. NOW APU BATT CHARGER CONSIDER INOP. NEW POSITION OF PARTS ARE INSTALLED AS FOLLOW: MAIN BATT P/N 416541 S/N USN 090520024837B MAIN BATT CHARGER P/N 920000. S/N 09052 APU BATT P/N 263BA101-2 S/N 5274 APU BATT CHARGER P/N 263BC101-3. S/N 1740...AP;PROVED REPLACED APU BATTERY CHARGER REF AMM 24-31-06-400-801. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1239095 SN OFF 1740 CHARGER, BATTER OFF 25-2431-9-0002 1740 ON 25-2431-9-0002 1676
Part: RESERVOIR — USED (L1 DOOR) · airframe 105,586 hrs · 10,689 cycles
DURING ACCOMPLISHMENT OF W/C 85-5211-1-9800. FOUND EPASS BOTTLE AT L1 DEPLETED. REMOVED AND REPLACED L1 ENTRY DOOR RESERVOIR BOTTLE. REF AMM 52-11-20. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1107678 SN OFF 0115 ACCOMPLISHED AND VERIFIED RII INSP REQUIREMENT FOR L1 DOOR EPASS RESERVOIR BOTTLE. ALL TEST / OPERATION NORMAL. NO DEFECTS NOTED. REF: AMM 52-11-20. RESERVOIR, ENTR OFF 25-5211-9-9002 0115 ON 25-5211-9-9002 0409
Part: WARNING SYSTEM — FALSE INDICATION (NA) · airframe 105,418 hrs · 10,658 cycles
CREW REPORTS LOW SPEED ABORT AT 80 KNOTS DUE TO AURAL WARNING THAT AIRCRAFT WAS ON A TAXIWAY. AC WAS ACTUALLY ON RUNWAY 9R. CREW ALSO REPORTS THEY NORMALLY RECEIVE AURAL NOTIFICATION WHEN APPROACHING A RUNWAY AND THERE WAS NONE WHEN THEY APPROACHED 9R. TERRAIN DATABASE INSTALLED 622. NEWEST IS 625. INSTALL NEW PICTURE ADDED DATABASE PER TOMC LOADED MOST CURRENT TERRAIN DATABASE VERSION 625 PER MM 34-45-00-470-802. PERFORMED GROUND PROXIMITY WARNING SYSTEM OPERATIONAL TEST PER MM 34-46-00-710-803-003. ADD EMP:104327
2021
Part: NONE — NONE (MLG) · airframe 104,271 hrs · 10,455 cycles
ON TO ABORT. RED EICAS MSG MAIN GEAR CONFIG ABORT 20KTS CONTACT TOMC WITH FINDINGS UNLOCKED FOR SIGNOFF WITH FINDINGS/CORRECTIVE ACTION. MSG #32-63020 SHOWS LATCHED. REF FIM 32-53 TASK 810. VERIFIED BOTH MLG STEERING ACTUATOR LEVERS ARE SET TO STEER POSITION AND LANDING GEAR PAGE SHOWS BOTH ACTUATORS LOCKED. OPERATED STEERING TILLER FULL LEFT + RIGHT,STATUS MSG ERASED.
Part: CHARGER — FAILED (EMERGENCY LIGHTS) · airframe 103,732 hrs · 10,351 cycles
B777-33-3-7015 - DR 3L EMER LIGHT POWER M33406 SUPPLY BATT CAPACITY TEST FAIL.
Part: CHARGER — FAILED (EMERGENCY LIGHTS) · airframe 103,732 hrs · 10,351 cycles
B777-33-3-7015 - DR 2L EMER LIGHT POWER SUPLY M33096 CAPACITY CHECK FAIL TRANFER FROM NR LP 9130404 AND ORIGINATED BY EMP V898181
Part: CHARGER — FAILED (EMERGENCY LIGHTS) · airframe 103,732 hrs · 10,351 cycles
B777-33-3-7015 - OHAR EMER LIGHT POWER SUPPLY CAPACITY CHECK FAIL TRANSFER FROM NR LP9130403 AND ORIGINATED BY EMP V898181
Part: CHARGER — FAILED (EMERGENCY LIGHTS) · airframe 103,732 hrs · 10,351 cycles
B777-33-3-7015 - DR 3L EMER LIGHT POWER SUPPLY M33400 CAPACITY CHECK FAIL TRANSFER FROM NR LP9130402 AND ORIGINATED BY EMP V898181
Part: BATTERY — INOPERATIVE (EMERGENCY LGIHT) · airframe 103,716 hrs · 10,348 cycles
L1 DOOR AFT EMERGENCY LIGHT BATTERY INOP REPLACED L1 DOOR AFT EMERGENCY LIGHT BATTERY REF AMM 33-51-06-960-802, OPS CHECK GOOD
Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 103,716 hrs · 10,348 cycles
L3 DOOR MID EMERGENCY LIGHT BATTERY INOP REPLACED L3 DOOR MID EMERGENCY LIGHT BATTERY REF AMM 33-51-06-960-802, OPS CHECK GOOD
2020
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 103,560 hrs · 10,313 cycles
B777-33-3-7019 - R3 DR EMER LT BATTERY PACK M33404 CAPACITY CHECK FAIL.REF NR LP 9130313 R3 DR EMER BATTERY PACK REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06 ADD EMP:V920591 IDT BY HX215617,APPROVED
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 103,560 hrs · 10,313 cycles
B777-33-3-7019 - R3 DR EMER LT BATTERY PACK M33401 CAPACITY CHECK FAIL.REF NR LP 9130312 R3 DR EMER BATTERY PACK REPLACED AND INSTALLATION TEST CARRIED O UT RESULT NORMAL IAW AMM 33-51-06 ADD EMP:V920591 IDT BY HX215617,APPROVED
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 103,560 hrs · 10,313 cycles
B777-33-3-7019 - R2 DR EMER LT BATTERY PACK M33097 CAPACITY CHEC K FAIL.REF NR LP 9130311 R2 DR EMER BATTERY CHARGER REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06 ADD EMP:V920591 IDT BY HX215617,APPROVED
2019
Part: OVEN — FAILED (GALLEY) · airframe 102,368 hrs · 10,194 cycles
OVEN 203 SMOKED AND FAILED. ELECTRIC SMELL R+R STEAMER OVEN #203 IN FWD GALLEY AS PER AMM 25-35-03,RAN STEAMER OVEN FOR 20 MINS ALL OPS CHK OK.
Part: BATTERY PACK — DISCHARGED (L1 DOOR) · airframe 100,545 hrs · 10,011 cycles
ON CHK FND L1 DOOR EPAS GREEN TEST INDICATOR LIGHT CONTINUOUSLY BLINK WHEN SAFETY SWITCH IN "ARM" POSITION. L1 DOOR EPAS 9 VOLT BACK-UP BATTERIES REPLACED AND TEST CARRIED OUT "SATIS" IAW AMM 52-11-20 DEFECT UPDATE: CHK FND L1 DR EPAS GREEN TEST INDICATOR LIGHT "NOT" CONTINUOUSLY BLINK WHEN SAFETY SWITCH IN "ARM" POSITION.
2018
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 95,964 hrs · 9,601 cycles
L3 DOOR EMERGENCY LIGHT POWER SUPPLY BATTERY HAD LOW CAPACITY. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 95,964 hrs · 9,601 cycles
L3 DOOR EMERGENCY LIGHT POWER SUPPLY M33400 CHARGER WAS INOPERATIVE. THE POWER SUPPLY CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: CHARGER — INOPERATIVE (EMERGENCY LIGHT) · airframe 95,964 hrs · 9,601 cycles
L3 DOOR EMERGENCY LIGHT POWER SUPPLY M33400 CHARGER WAS INOPERATIVE. REPLACED THE CHARGER , TESTED NORMAL IAW AMM 33-51-06
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHT) · airframe 95,964 hrs · 9,601 cycles
L2 DOOR EMERGENCY LIGHT BATTERY PACK M33096 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK M33096 WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 95,964 hrs · 9,601 cycles
R2 DOOR EMERGENCY LIGHT BATTERY PACK M33097 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 95,964 hrs · 9,601 cycles
R4 DOOR EMERGENCY LIGHT BATTERY PACK M33408 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK M33408 REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 95,964 hrs · 9,601 cycles
R2 DOOR EMERGENCY LIGHT BATTERY PACK M33098 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY — DISCHARGED (CABIN) · airframe 95,964 hrs · 9,601 cycles
DR L2 OVERDOOR EMER LT POWER SUPPLY M33099 BATTERY PACK LOW CAPACITY. DR L2 OVERDOOR EMER LIGHT POWER SUPPLY BATTERY M33099 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.
Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 95,964 hrs · 9,601 cycles
OHAR AREA EMER LT FOUND DIM. OHAR AREA EMER LIGHT POWER SUPPLY BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.
Part: BATTERY — DISCHARGED (CABIN) · airframe 95,964 hrs · 9,601 cycles
DR L3 OVERDOOR EMER LT POWER SUPPLY M33400 BATTERY PACK LOW CAPACITY. DR L3 OVERDOOR EMER LIGHT POWER SUPPLY BATTERY M33400 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.
Part: FITTING — CRACKED (LT ELEVATOR) · airframe 95,964 hrs · 9,601 cycles
LEFT ELEVATOR OTBD ACTUATOR FITTING, ONE CRACK WAS FOUND, APPROXIMATELY 7/16 INCH IN LENGTH.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 94,440 hrs · 9,461 cycles
MED 2L EXTERIOR EMERGENCY LIGHT INOP RELAMPED, OPS CHECKS GOOD. REF AMM 31-51-04-960-801
Part: CONNECTOR — MELTED (LAV LIGHT) · airframe 94,164 hrs · 9,430 cycles
ELECTRICAL BURNING ODOR IN LAVATORY G. FOUND MELTED FLOURECENT TUBE CONNECTOR. REMOVED AND REPLACED THE BALLAST AND LIGHT SOCKET IAW AMM 33-26-00. OPS CHECKED NORMAL.
2017
Part: LIGHT — INOPERATIVE (CABIN) · airframe 92,035 hrs · 9,238 cycles
ON CHK FOUND EMER LT AT R1 INOP. EMER LT AT R1 RELAMP AND TEST OKAY IAW AMM 33-51-00.
Part: WARNING SYSTEM — FALSE ACTIVATION (R3 DOOR) · airframe 90,670 hrs · 9,114 cycles
DOOR WING SLIDE R EICAS ADVISORY. THE RIGHT SLIDE COMPARTMENT DOOR IS EITHER OPEN, CLOSED BUT NOT LOCKED ON THE GROUND, OR THE STATE OF THE PROXIMITY SENSOR CANNOT BE DETERMINED CYCLED DOOR 3R SEVERAL TIMES, DOOR INDICATION GOOD AT CSCP, NO FAULTS NOTED AT THIS TIME.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 90,120 hrs · 9,065 cycles
EMERG LIGHT EICAS MESSAGE ON RECALL. EMERG LIGHTS OPERATIONAL TEST GOOD PER AMM 33-51-00. EICAS NOT ILLUMINATED ON RECALL.
2016
Part: CHARGER — FAULTY (CABIN) · airframe 83,970 hrs · 8,545 cycles
L2 DOOR EXTERIOR EMER SLIDE LIGHT & L2 DOOR AFT INTERIOR EMER EXIT IDENTIFIER SIGN INOPERATIVE. ALSO LT CEILING EMER LIGHT INOPERATIVE BETWEEN L2 DOOR & L3 DOOR. IAW AMM 33-51-06 EMER LIGHT POWER SUPPLY CHARGER & BATTERY PACK AT L2 DOOR M33099 REPLACED & TESTED SATISFACTORY.
2015
Part: CHARGER — INOPERATIVE (CABIN) · airframe 81,276 hrs · 8,300 cycles
LEFT DOOR 3, M33405 EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. LEFT DOOR 3 EMER LIGHT BATTERY CHARGER. REPLACED & OPERATION TESTED NORMAL IAW AMM 33-51-06.
Part: CHARGER — INOPERATIVE (CABIN) · airframe 81,276 hrs · 8,300 cycles
LEFT DOOR 4, 33407 EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. LT DOOR 4 LIGHT BATTERY CHARGER M33407 REPLACED & OPERATION TESTED NORMAL IAW AMM 33-51-06.
Part: CHARGER — INOPERATIVE (CABIN) · airframe 81,276 hrs · 8,300 cycles
LEFT DOOR 1, M33424 EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. LT DOOR 1 EMER LIGHT BATTERY CHARGER REPLACED & OPERATION TESTED NORMAL IAW AMM 33-51-06.
Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 80,947 hrs · 8,268 cycles
ON CHECK FOUND RT 4 DOOR EMER EXIT SIGN LIGHT INOPERATIVE. L33541 INOPERATIVE POWER SUPPLY. M33408 REPLACED & CHECKED SATISFACTORY AMM 33-51-06.
Part: POWER SUPPLY — FAILED (CABIN) · airframe 80,947 hrs · 8,268 cycles
RIGHT DOOR, 4 EMER SIGN LIGHT INOPERATIVE IAW WDM 33-51-34. POWER SUPPLY M33408 FAILED. REPLACED POWER SUPPLY. CHECKED SATISFACTORY AMM 33-51-06.
Part: SLIDE — DEPLETED (R3 DOOR) · airframe 80,379 hrs · 8,215 cycles
DOOR 3R SLIDE DEPLOYED. PERFORMED SLIDE RESTORATION IAW AMM 25-66-00-810-801. INSTALLED 3R SLIDE IAW AMM 25-65-01-400-801 & FORM 46-0035. ROTABLE PARTS CHANGE WAS INDICATED. TT 1709614, SN OFF 00431 SLIDE, B777-200 OFF 25-2560-9-0008 0431 ON 25-2560-9-0008 0021.
Part: WIRE — BROKEN (L1 DOOR) · airframe 79,208 hrs · 8,110 cycles
L1 DOOR EPAS BATTERY PACK FAILED OPERATIONAL CHECK. REF JOB CARD JE25-5210-1-9801. IAW WDM 52-11-13 FOUND WIRE W3070-2004 R2 AT PIN 11 CONNECTOR DM52105 BROKEN. REPINNED IAW SWPM 20-30-00. OPERATIONS CHECKED NORMAL. ROTABLE PARTS CHANGE WAS INDICATED, TT 1814915 SN OFF 01983 BATTERY, EMER OFF 25-5211-9-9051 1983 ON 25-5211-9-9051 7664.
Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 79,015 hrs · 8,095 cycles
L3 DOOR CTR EMER LIGHT BATTERY PACK FOUND INOPERATIVE. L3 DOOR CTR EMER LIGHT BATTERY PACK REPLACED & TESTED NORMAL IAW AMM 33-51-06.
2013
Part: BATTERY — FAILED (E&E BAY) · airframe 72,365 hrs · 7,518 cycles
SMOKE ODOR IN FLIGHT DECK CABIN. SMOKE ODOR IN FLIGHT DECK CABIN CONDITIONAL INSPECTION CHECKED OUT IAW AMM TASK 05-51-58-800-801C3 - SATISFACTORY
Part: CONTROLLER — INOPERATIVE (LEFT ENGINE) · airframe 70,657 hrs · 7,361 cycles
AFTER T/O "ENG BLEED LT OFF EICAS" LT BLEED VALVE FUEL DUMP AND RETURNED TO EWR. REFER TO L/P 7351111 PARTS CHANGE AND OPS TEST.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
R4 DOOR EMERGENCY LIGHT BATTERY, M33409, CAPACITY CHECK FAILED. BATTERY, REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
L3 DOOR EMERGENCY LIGHT BATTERY, M33405 CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
L1 DOOR EMERGENCY LIGHT BATTERIES M33093, M33424, FOUND CAPACITY CHECK FAILED. BATTERIES REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
R2 DOOR EMERGENCY LIGHT BATTERIES M33097, M33098 FOUND CAPACITY CHECK FAILED. BATTERIES REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — FAILED (CABIN R3) · airframe 69,594 hrs · 7,264 cycles
R3 DOOR EMERGENCY LIGHT BATTERY M33401 CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
R1 DOOR EMERGENCY LIGHT BATTERY, M33094, CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
L2 DOOR EMERGENCY LIGHT BATTERY, M33096, CAPACITY CHECK FAILED. BATTERY, REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 69,594 hrs · 7,264 cycles
L4 DOOR EMERGENCY LIGHT BATTERY, M33407 FOUND CAPACITY CHECK FAILED. BATTERY PACK REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
2012
Part: SKIN — DENTED (CARGO DOOR) · airframe 38,828 hrs · 4,401 cycles
FOUND SMALL SCRATCH AND DENT ON FWD LWR EDGE OF BULK CARGO DOOR SKIN DAMAGED. FOUND TO BE WITHIN LIMITS IAW SRM 52-30-01.
Part: CAP — DAMAGED (CABIN) · airframe 64,933 hrs · 6,856 cycles
EMERGENCY LIGHT 3E MISSING. REMOVED AND REPLACED BROKE CAP AND ASSEMBLY. UNIT CHECKS GOOD. A/C OK TO CONTINUE.
Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 64,754 hrs · 6,840 cycles
FLASHLIGHT AT DOOR 4R INOP. REPLACED FLASHLIGHT BATTERY & STRAP AT DOOR 4R. CHECKS GOOD.
Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 64,754 hrs · 6,840 cycles
FLASHLIGHT AT DOOR 4L INOP. REPLACED FLASHLIGHT BATTERY & STRAP AT 4L, CHECKS GOOD.
2011
Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 62,080 hrs · 6,606 cycles
DOOR 4L JUMPSEAT INBOARD HAND HELD EMERGENCY FLASHLIGHT LED DOES NOT TEST. REMOVED AND REPLACED FLASHLIGHT BATTERY AMM 25-64-01-710-801.
Part: UNKNOWN — MALFUNCTIONED (RUDDER) · airframe 59,443 hrs · 6,359 cycles
FLT 7000 WITH 56KN DIRECT CROSS WIND FROM RT, A/C HAD CONTINUOUS SMOOTH UNCOMMANDED RUDDER INPUTS. YAW DAMPER INDICATIONS WERE 1/2 LEFT TO 1/3 RIGHT DISPLACEMENT. THIS CONDITION LASTED FOR AS LONG AS WIND WAS REG L/P 8751429 FOR CORRECTIVE ACTION.. LOG PG 8751429 CONT, WITH A/P ON AND OFF NO CHANGE. EMERGENCY WAS DECLARED FOR LANDING PRIORITY. C9005 STA EWR 27 FEB 11 ATA 02700 / NO EICAS MSG NOTED, NO MX MSG NOTED. PERFORMED PFCS ACTUATOR / CONFIDENCE, ACTUATOR CONTROL ELE MONITOR TEST AND GUST SUPPRESSION PRESSURE TRANSDUCER TEST PER FIM. ALL TEST PASSED. NO FAULTS NOTED.
2007
Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 38,825 hrs · 4,400 cycles
INSPECTION FOUND SEAT TRACK CORRODED AT STA 1510-1586, RBL 108. REPAIRED IAW SRM 53-00-52, REPAIR 4, FIGURE 202.
2006
Part: APU — FAILED (APU BAY) · airframe 35,054 hrs · 3,997 cycles
A FLIGHT ATTENDANT AT ROW 34 REPORTED AN ELECTRICAL AND SMOKY ODOR SHORTLY AFTER LEVEL OFF AT FL 360 EN ROUTE TO EWR. NO SMOKE WAS VISIBLE. THE ODOR WAS ONLY MOMENTARY. THE FLIGHT WAS CONTINUED TO EWR WHERE IT LANDED WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND THE APU HAD FAILED AND LEAKED OIL INTO THE PACK DUCTS. THE APU WAS REMOVED AND REPLACED IAW MM 49-11-01. IN ADDITION, THE LT AND RT ACM'S AND HEAT CONDENSERS, AND RT HEAT EXCHANGER WERE REMOVED AND REPLACED. A PACK BURNOUT PROCEDURE WAS PERFORMED AND THE RECIRCULATION FILTERS WERE REPLACED. OPERATIONAL CHECKS WERE GOOD AND A HIGH POWER RUN WAS PERFORMED WITH NO SMOKE OR ODORS OBSERVED.
2003
Part: DOOR FRAME — CRACKED (FWD CARGO DR) · airframe 19,157 hrs · 2,211 cycles
INSPECTION FOUND A 1" CRACK IN FORWARD CARGO DOOR FRAME UPPER EDGE APPROXIMATELY 21 INCHES FROM FORWARD EDGE. IN ADDITION, THE AREA WAS SCRATCHED AND GOUGED. REPAIRED IAW ECRA 5230-01718.
Part: WINDOW FRAME — GOUGED (STA 710) · airframe 19,157 hrs · 2,211 cycles
INSPECTION FOUND A GOUGE IN L/H PASSENGER WINDOW CUTOUT FRAME AT AFT EDGE, STA 710. REPAIRED IAW ECRA 5330-03227.
Part: SKIN — DENTED (BS 676) · airframe 19,157 hrs · 2,211 cycles
INSPECTION FOUND L/H FUSELAGE SKIN DENTED AT BS 676 BETWEEN S27L AND S28L. REPAIRED IAW SRM 53-00-01, REPAIR 7, FIGURE 202. A DIP WAS INITIATED TO REINSPECT THE REPAIR AT 30,000 FLIGHT CYCLES WITH REPEAT INSPECTION AT 16,000 FLIGHT CYCLES PER SRM 53-00-01, REPAIR 7, TABLE 204.
Part: SEAT TRACK — CORRODED (BS 1485-1520) · airframe 19,157 hrs · 2,211 cycles
INSPECTION FOUND SEAT TRACK CORRODED AT BS 1485-1520, RBL 74. THE SEAT TRACK WAS REPAIRED IAW SRM 53-00-52, REPAIR 3, FIGURE 202.
Part: SKIN — NICKED (BS 626) · airframe 19,157 hrs · 2,211 cycles
INSPECTION FOUND FUSELAGE SKIN NICKED AT BS 626, S3L. A FLUSH REPAIR WAS INSTALLED IAW SRM 53-00-01, REPAIR 2, FIGURE 202.
Part: SEAT TRACK — CORRODED (BS 1500) · airframe 19,157 hrs · 2,211 cycles
INSPECTION FOUND SEAT TRACK CORRODED AT BS 1500, RBL 88. THE SEAT TRACK WAS REPLACED IAW SRM 51-10-2 AND 51-40-02.