Accident & incident history

Lockheed L-1011-385-1-15 Serious injury Part 121operator not named in the NTSB record
Source: NTSB case LAX97FA276

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

41 reports on file, 1995-09-15 – 2001-04-23.

FALSE WARNING · 2001-04-23 Matched by certificate designator
ATA 3260

Part: DOWNLOCK SENSOR — OUT OF ADJ (NLG) · airframe 73,704 hrs · 19,094 cycles

ORD/ 601121 WHEN THE GEAR WAS EXTENDED NLG LIGHT DID NOT ILL. TRANS LIGHT REMAINED ON. WENT THRU POM PROCEDURES CK, VISUAL INDICATION DOWN AND LOCKED. AFTER 15 MIN NLG LIGHT GREEN ILLUMINATED . NORM LDG MADE JACKED A/C ADJ NLG DOWN LOCK SENSOR PER M/M TO PROPER CLEARANCES. RETRACTED AND CYCLED SAME SEVERAL TIMES. ALL IND. AND RATIONAL CKS NORM

Source: SDR DLL14010669
OTHER · 2001-01-23 Matched by certificate designator
ATA 5320

Part: INTERCOSTAL — CRACKED (FUSELAGE) · airframe 72,923 hrs · 18,799 cycles

A SCHEDULED REPEAT INSPECTION OF THE L4 DOOR SURROUND STRUCTURE REVEALED A CRACK IN THE NR 2 DOOR STOP BACK-UP INTERCOSTAL AT FS 1809. THE CRACK IS ACCEPTABLE PER LOCKHEED S/B 093-53-270 FOR 2500 FLIGHT CYCLES WITH 600 CYCLE REPEAT INSPECTIONS. ER/A 377845-14, REV A WAS ISSUED TO TRACK THE COMPLIANCE FOR THIS ITEM.

Source: SDR DLL14010139
OTHER · 2001-01-23 Matched by certificate designator
ATA 5310

Part: DOOR FRAME — CRACKED (FUSELAGE) · airframe 72,923 hrs · 18,799 cycles

A SCHEDULED INSPECTION OF THE R4 DOOR SURROUND STRUCTURE REVEALED A CRACK IN THE NR 2 DOOR STOP ATTACH FITTING AND THE NR 2 DOOR STOP INTERCOSTAL. A CRACK WAS ALSO FOUND IN THE NR 3 DOOR STOP INTERCOSTAL. LOCKHEED S/B ALLOWS CONTINUED SERVICE ON A TIME LIMITED BASIS WITH 2 CRACKED INTERCOSTALS. THE ATTACH FITTING WAS REPLACED AND THE TIME LIMIT AND INSPECTION SCHEDULE OF THE INTERCOSTALS DOCUMENTED PER ER/A 377844-14, REV A.

Source: SDR DLL14010140
NO TEST · 2001-01-06 Matched by certificate designator
ATA 3340

Part: POWER SUPPLY — DISCHARGED (R1 DOOR) · airframe 72,822 hrs · 18,767 cycles

R1 EXTERIOR DOOR LIGHT DID NOT ILLUMINATE. REPLACED R1 POWER SUPPLY.

Source: SDR DLL14010026
Earlier reports · 1995–2000 · 37 reports

2000

NO TEST · 2000-10-31 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 72,108 hrs · 18,596 cycles

ALL EMERGENCY EXIT SIGNS INOP AT R-3 DOOR. REPLACED PWR SUPPLY. CHECKS NORMAL.

Source: SDR DLL14002142
FLAME/FIRE · 2000-09-14 Matched by certificate designator
ATA 7430

Part: SWITCH — FAILED (NR 3 ENGINE) · airframe 71,570 hrs · 18,470 cycles

NUMBER 3 ENGINE FUEL AND IGN CUTOFF SWITCH WOULD NOT SHUT OFF, USED TANK VALVE LATCH TO SECURE ENG. RESIDUAL FUEL IN LINES CAUSED A TAIL PIPE FIRE. SPUN ENGINE UNTIL FIRE EXTINGUISHED. FIRE DEPARTMENT WAS CALLED BUT THEY WHERE NOT NEEDED. REPLACED ENGINE.

Source: SDR DLL14001777
NO TEST · 2000-09-04 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 71,489 hrs · 18,441 cycles

FOUND ON L/O, 3R EMERGENCY EXIT SIGN INOP. REPLACED 3R POWER SUPPLY PER MM EMERGENCY EXIT SIGN LIGHT AND OUTSIDE EVAC LIGHT, OPS CKS OK.

Source: SDR DLL14001700
ENGINE FLAMEOUT · 2000-08-25 Matched by certificate designator
ATA 7320

Part: REGULATOR — FAILED (NR 3 ENGINE) · airframe 71,365 hrs · 18,411 cycles

NR 3 ENGINE FAILED FOR NO OBSERVABLE REASON NINETY MINUTES AFTER T/O. SEE ATTACHED REPORT ENGINE FAILURE AND SHUTDOWN CHECKLISTS ACCOMPLISHED. REPLACED FUEL FLOW REG (S/N B1671) ON AND FUEL PUMP (S/N B 1368) ON, LK CKS OK, RAN AND ADJUSTED PER PFHB.

Source: SDR DLL14001653
OTHER · 2000-07-14 Matched by certificate designator
ATA 5340

Part: ATTACH FITTING — CRACKED (FUSELAGE) · airframe 70,952 hrs · 18,308 cycles

THE ATTACH FITTING COMMON TO THE R4 DOOR NR 1 DOOR STOP INTERCOSTAL AND THE AFT PRESSURE BULKHEAD WAS FOUND CRACKED. THE CRACK IS TYPICAL OF LAC S/B 093-53-270. THE ADJACENT FITTINGS WERE FOUND UNDAMAGED. THE CRACKED FITTING WAS AUTHORIZED FOR CONTINUED SERVICE ON A TIME-LIMITED BASIS PER THE S/B AND ER/A 377844-14.

Source: SDR DLL14001339
OTHER · 2000-07-14 Matched by certificate designator
ATA 5340

Part: ATTACH FITTING — CRACKED (FUSELAGE) · airframe 70,952 hrs · 18,308 cycles

THE ATTACH FITTING COMMON TO THE L4 DOOR NR 1 DOOR STOP INTERCOSTAL AND THE AFT PRESSURE BULKHEAD WAS FOUND CRACKED. THE CRACK IS TYPICAL OF LAC S/B 093-53-270. THE ADJACENT FITTINGS WERE FOUND UNDAMAGED. THE CRACKED FITTING WAS AUTHORIZED FOR CONTINUED SERVICE ON A TIME-LIMITED BASIS PER THE S/B AND ER/A 377845-14.

Source: SDR DLL14001338
FLUID LOSS; WARNING INDICATION · 2000-03-29 Matched by certificate designator
ATA 7261

Part: ENGINE — LEAKING (NR 3) · airframe 69,837 hrs · 18,004 cycles

SHUT DOWN NR 3 ENG DUE TO A RAPID LOSS OF OIL QTY AFTER 40 MINS OF FLIGHT. OIL QTY HAD DROPPED FROM 17 QTS TO 7.5 QTS. REPLACED OIL PUMP AND FUEL/OIL HEAT EXCHANGER.

Source: SDR DLL14000598
FLUID LOSS; WARNING INDICATION · 2000-03-28 Matched by certificate designator
ATA 3230

Part: PRIORITY VALVE — CRACKED (LT MLG) · airframe 69,837 hrs · 18,004 cycles

A/C LOST C-HYD JUST AFTER GEAR DOWN AND PUTTING FINAL FLAPS QUANITY TO 1/4 AND PRESS WENT TO ZERO. FOUND DIFFERENTIAL PRIORITY VALVE CRACKED. REPLACED SAME PER MM.

Source: SDR DLL14000596
NO TEST · 2000-01-06 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — DISCHARGED (L4 DOOR) · airframe 69,036 hrs · 17,770 cycles

EXT DOOR LIGHT DID NOT ILLUMINATED.

Source: SDR DLL14010027

1999

FLAME/FIRE; WARNING INDICATION · 1999-09-26 Matched by certificate designator
ATA 8011

Part: STARTER — FAILED (NR 3 ENGINE)

C/B 1F18 NR 3 ENGINE HP FUEL SOV POPPED. RESET ONCE, POPPED AGAIN. UPON SHUTDOWN LAX, ENCOUNTERED A TAILPIPE FIRE NR 3 ENGINE. NR 3 TANK VALVE CLOSED/STARTER ENGAGED/ MOTORED ENG FIRE HANDLE PULLED/ FIRE EXTINGUISHED. REPLACING STARTER/ NR 3 ENG. HP FUEL SOV. INSP ENGINE PER FIM. FOUND NR 3 ENGINE GLOVE FAIRING PAINT BLISTERED.

Source: SDR DLL14992149
INFLIGHT SEPARATION; VIBRATION/BUFFET · 1999-09-19 Matched by certificate designator
ATA 3231

Part: ROD — MISSING (LT MLG DOOR)

VIBRATION IN FLOOR CAPTS SIDE NEAR SEAT ROWS 31, 32 AND 33.

Source: SDR DLL14992102
SMOKE/FUMES/ODORS/SPARKS · 1999-08-12 Matched by certificate designator
ATA 2530

Part: COFFEEMAKER — FAILED (GALLEY)

ELECTRIC SMOKE FROM MID GALLEY COFFEEMAKER AREA ON, CAPTAIN'S SIDE. SMOKE STOPPED WHEN COFFEEMAKERS WERE TURNED OFF. REPLACED BOTH COFFEE MAKERS.

Source: SDR DLL14991799
OTHER · 1999-07-23 Matched by certificate designator
ATA 5512

Part: SKIN — CRACKED (HORIZ STAB)

HORIZONTAL STABILIZER LEFT UPPER SKIN, HSS 80, STIFFENER NR 31 SKIN CRACK. REPAIR THE NR 4 UPPER SKIN PANEL OF THE LEFT HORIZONTAL STABILIZER WAS FOUND WITH A 1.25 CRACK AT THE RUNOUT OF STIFFENER NR 31. THE CRACK WAS ROUTED OUT OF THE SKIN AND AN EXTERNAL ALUMINUM DOUBLER AND TRIPLER WERE INSTALLED PER ER/A 367841-14, REV A.

Source: SDR DLL14991656
FLUID LOSS; WARNING INDICATION · 1999-06-30 Matched by certificate designator
ATA 7210

Part: GEARBOX — FAILED (NR 2 ENGINE)

OIL QUANTITY GAUGE WENT TO ZERO, HAD OIL PRESS CONTINUE TO DECREASE. AS PRECAUTIONARY ENG SHUTDOWN POM. REPLACED NR 2 ENGINE GEARBOX FOR LEAKING.

Source: SDR DLL14991481
OTHER · 1999-05-04 Matched by certificate designator
ATA 3350

Part: LIGHT — DAMAGED (ROW 1)

EMERGENCY TRACK LIGHTING ALONG SIDE SEAT 1D IS DAMAGED. RELAMPED AND REPLACED LENS. OPS CK GOOD.

Source: SDR DLL14990982
WARNING INDICATION · 1999-03-19 Matched by certificate designator
ATA 2612

Part: CONNECTOR — FAILED (NR 3 ENGINE)

NOTIFIED BY OPS AROUND 1900 THAT FLT 54 NR 3 ENG FIRE WARNING LIGHT ILLUMINATED AND SHUT ENG DOWN AND USED FIRE EXTINGUISHER BOTTLE AND DUMPING FUEL. REPLACED PLUG AT NR 3 FDCU.

Source: SDR DLL14990597
FALSE WARNING · 1999-03-13 Matched by certificate designator
ATA 2612

Part: CONNECTOR — FAILED (NR 3 ENGINE)

DURING CLIMBOUT, FIRE WARNING LIGHT CAME ON WITH INTERMITTANT FIRE BELL B LOOP ON NR 3 ENG ILLUMINATED. A LOOP ALREADY ON MCO. SHUTDOWN NR 3 ENG PER POM PROCEDURE. RANG OUT B LOOP PER FIM, CLEANED ALL CONNECTORS, REPLACED CONNECTOR P715 ON A LOOP, RAN ENGS PER PFHB. NO LIGHTS, ALL NORMAL.

Source: SDR DLL14990537

1998

SMOKE/FUMES/ODORS/SPARKS · 1998-11-10 Matched by certificate designator
ATA 2430

Part: CIRCUIT BREAKER — SHORTED (COCKPIT)

NEAR TOP OF DESCENT, ELECTRICAL SPARKING AND ARCING BELOW DC STANDBY POWER CIRCUIT BREAKER. WHITE IN COLOR FOLLOWED BY ELECTRICAL SMELLING SMOKE AND RED GLOW OF HOT METAL/FIRE, BEHIND AND BELOW CIRCUIT BREAKER NUMBER 3F1. APPLIED HALON EXTINGUISHER TO GLOWING AREA AND GLOW WENT OUT. MULTIPLE SYSTEM FAILURES ENSUED. FOUND WIRE BUNDLE CLAMP SHORTED AGAINST STANDBY DC POWER CIRCUIT BREAKER TERMINAL. ADDITIONAL SYSTEM FAILURES RELATED TO DC STANDBY RELAY. REPLACED CLAMP AND BREAKER AND CHECKED ALL SYSTEMS INVOLVED.

Source: SDR DLL14982317
NO TEST · 1998-10-23 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOP (EXTERIOR)

NUMBER TWO RIGHT EXTERIOR EMERGENCY LIGHT INOP. REPLACED POWER SUPPLY, CHECKS NORMAL PER MM.

Source: SDR DLL14982196
NO TEST · 1998-10-16 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

FIRST CLASS EMERGENCY LIGHTS INOP. MTC REPLACED BATT PACK AND RACK. OPN NORMAL NOW.

Source: SDR DLL14982148
INADEQUATE Q C · 1998-07-23 Matched by certificate designator
ATA 5312

Part: BULKHEAD — MISDRILLED (BS 1363)

DURING REWORK OF THE 1363 BULKHEAD PER S/B 093-53-268, SEVERAL FASTENER HOLES WERE MISDRILLED AND SEVERAL FASTENERS WERE INSTALLED WHICH DEVIATE FROM THE S/B. REPAIRED PER ERA 331959-14.

Source: SDR DLL14981531
OTHER · 1998-07-16 Matched by certificate designator
ATA 2560

Part: GIRT BAR — OUT OF ADJUST (R4 DOOR)

GIRT BAR INOP, WILL NOT ENGAGE LATCH WHEN R4 DOOR IS CLOSED. ADJUSTED GIRT BAR, OPS CHECK NORMAL.

Source: SDR DLL14981479
NO TEST · 1998-07-08 Matched by certificate designator
ATA 2560

Part: GIRT BAR — OUT OF ADJUST (L4 DOOR)

GIRT BAR WOULD NOT LATCH IN PLACE ON L4 DOOR DURING OPN TEST DURING HMV. NR 29 NO CLEARANCE BETWEEN GIRT BAR AND LATCH COVER AT L4 DOOR. ADJUSTED PER M/M 25-61-00.

Source: SDR DLL14981435
OTHER · 1998-06-07 Matched by certificate designator
ATA 5210

Part: MECHANISM — OUT OF ADJUST (PAX DOOR)

COUNTER BALANCE REPLACE, WAS SLOW TO OPERATE IN MANUAL, (EMERGENCY MODE). S/N NR OFF 1095, S/N NR ON 1194.

Source: SDR DLL14981513
FLUID LOSS; WARNING INDICATION · 1998-05-12 Matched by certificate designator
ATA 7261

Part: OIL TUBE — CRACKED (NR 3 ENGINE)

EN ROUTE TO HNL CONT DROP NR-3 OIL QTY DIVERTED TO SFO. QTY, DROPPED TO 3.1 QTS SHORTLY AFTER DROPPED TO ZERO NML TEMP/PRESS AT 2055Z OIL PRESS FLUCT 10 PSI FROM 35 TO 55 PSI, ENG SHUT DN AT THAT TIME AND FOLLOW UP PROC ACCOMP. FOUND OIL TUBE CRACKED AT OIL RETURN COMBUSTION LP TURBINE BRG TO 3 WAY CONN ASSY.

Source: SDR DLL14981023
NO TEST · 1998-05-10 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

L1 AND L3 EMER SLIDE LGTS INOP. REPLACED PWR SUPPLY, CKS GOOD.

Source: SDR DLL14980990
VIBRATION/BUFFET · 1998-05-02 Matched by certificate designator
ATA 7250

Part: TURBINE BLABE — DAMAGED (NR 3 ENGINE)

NR 3 ENGINE HIGH VIBRATION ON CLIMB. ENGINE SHUTDOWN AND RTN TO TPA. BORESCOPED ENGINE FOUND HPT BLADE DAMAGE. REPLACED ENGINE.

Source: SDR DLL14980943
NO TEST · 1998-04-03 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (CABIN)

DURING L/O, FOUND EXTERIOR EMERGENCY LIGHTS OUT AT L1 AND L3 DOORS. RELAMPED, OPS CK GOOD.

Source: SDR DLL14980721
NO TEST · 1998-03-18 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

EMERGENCY LIGHT PWR SUPPLY STAYS ON AFTER TURNING LIGHTS OFF. REPLACED BATTERY PACK.

Source: SDR DLL14980609
FLUID LOSS; WARNING INDICATION · 1998-02-15 Matched by certificate designator
ATA 2710

Part: ACTUATOR — BROKEN (LT AILERON)

HYD SYS-A FLUID LEVEL DROPPED TO 1/4 DURING CRUISE FLT. UNLATCHED ENG PUMP S/O SWITCH FOR HYD SYS-A AND FLUID LOSS STOPPED. FOUND LT OUTBD ACTUATOR OF INBD AILERON BROKEN AND HYD LINE AT ACT BROKEN. REPLACED SAME PER MM, ALL CKS OK. CKD A-PUMP HYD FILTERS FOR METAL, ALL OK.

Source: SDR DLL14980391

1997

OTHER · 1997-08-07 Matched by certificate designator
ATA 2565

Part: SLIDE — MALFUNCTIONED (R4 DOOR)

FOUR RIGHT DOOR DID NOT OPEN AND THE SLIDE DID NOT DEPLOY DURING EVACUATION. FOUND 'T' HANDLE NOT FULLY DEPLOYED, OPS CHECK NORMAL.

Source: SDR DLL14971585
OTHER · 1997-08-07 Matched by certificate designator
ATA 5210

Part: SPRING — BROKEN (R2 DOOR)

TWO RIGHT DOOR DID NOT OPEN COMPLETELY DURING EVACUATION AND SLIDE DID NOT DEPLOY. SUSPECT WEAK COUNTER BALANCE HOWEVER TESTED OK PER AMM. REPLACED SLIDE AND COUNTER BALANCE. COUNTER BALANCE RETURNED TO MANUFACTURER (TALAIR) AND DID NOT MEET TORQUE LIMITS. ONE OUTER SPRING WAS FOUND BROKEN AND EXCESSIVE WEAR WAS ON THE INNER AND OUTER RACES OF A BEARING.

Source: SDR DLL14971584
FLUID LOSS; WARNING INDICATION · 1997-05-16 Matched by certificate designator
ATA 2910

Part: UNION — CRACKED (C-HYD SYST)

LOST HYD SYS-C AT CRUISE. FLUID LEVEL AND PRESS DROPPED TO ZERO, LO QTY AND LO PRESS LIGHTS ILLUMINATED AND C2 ATM STARTED RUNNING. ACCOMPLISHED C/L PROCEDURES, MANUAL GEAR EXTENSION. FOUND CRACKED UNION JUST O/B OF C-SYSTEM PUMP. REPLACED SAME.

Source: SDR DLL14970936

1996

NO TEST · 1996-10-16 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

E-PATH LIGHTS ON, IN BOTH AISLES IN SECTIONS. REPLACED BATTERY PACK AND RACK AT 2L DOOR FOR E-PATH, OPN NORMAL.

Source: SDR DLL14962331
NO TEST · 1996-06-01 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

2L AND 2R EMERGENCY EXTERIOR LIGHTS INOP. C/A: REPLACED EMERGENCY BATTERY PACKS FOR 2L AND 2R, CKS OK.

Source: SDR DLL14961334

1995

ENGINE FLAMEOUT; WARNING INDICATION · 1995-10-26 Matched by certificate designator
ATA 7314

Part: FUEL PUMP — FAILED (NR 2 ENGINE)

NR 2 ENGINE FLAMED OUT AT FL 370. LANDED ATL WITHOUT INCIDENT. REPLACED ENGINE DRIVEN FUEL PUMP AND FFR. OPERATION NORMAL.

Source: SDR DLL14954110
FLUID LOSS; WARNING INDICATION · 1995-09-15 Matched by certificate designator
ATA 3230

Part: PRIORITY VALVE — FAILED (LT MLG)

THE C-HYDRAULIC SYSTEM FELL TO .25 FULL WHEN GEAR EXTENDED. FOUND LT MLG PHASE CONTROL VALVE, PRIORITY VALVE END CAP SHEARED. REPLACED PRIORITY VALVE, LEAK CHECK OK.

Source: SDR DLL14953708