N750XJ

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
XOJET Aviation LLC (AWKA)Certificate holder—Matched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

8 reports on file, 2009-09-07 – 2024-03-16.

OTHER · 2024-03-16 Matched by certificate designator
ATA 5310

Part: DOOR FRAME — GOUGED (ESCAPE HATCH) · airframe 17,663 hrs · 8,533 cycles

DURING INTERNAL ZONAL INSPECTION FOUND THE PSU SCREWS CONTACTED STRUCTURE AROUND THE E-EXIT DOOR FRAME. ACCOMPLISHED FIELD REPAIR - GOUGE, FUSELAGE, EMERGENCY ESCAPE HATCH SURROUND, FS336 THROUGH FS356 (FR-750-0250-13015 REV. A).

Source: SDR AWKA2024052707501
OTHER · 2024-03-16 Matched by certificate designator
ATA 5310

Part: DOOR FRAME — GOUGED (ESCAPE HATCH) · airframe 17,663 hrs · 8,533 cycles

RESUBMIT FROM 27-MAY-24: DURING INTERNAL ZONAL INSPECTION FOUND THE PSU SCREWS CONTACTED STRUCTURE AROUND THE E-EXIT DOOR FRAME (P/N 6711256-31). ***ACCOMPLISHED FIELD REPAIR FR-750-0250-13015 REV. A DATED 22-JAN-24 "FIELD REPAIR - GOUGE, FUSELAGE, EMERGENCY ESCAPE HATCH SURROUND, FS336 THROUGH FS356".

Source: SDR AWKA202405290004
FLUID LOSS; WARNING INDICATION · 2018-12-28 Matched by certificate designator
ATA 2910

Part: HYDRAULIC LINE — CRACKED (HYDRAULIC SYS) · airframe 13,306 hrs · 6,603 cycles

SOON AFTER DEPARTING BED, FLIGHT CREW NOTED THE “A” SYSTEM HYDRAULIC FLUID QUANTITY WENT TO ZERO PERCENTAGE. CREW RAN THE APPROPRIATE CHECKLIST, DECLARED AN EMERGENCY AND ELECTED TO DIVERT TO SWF, WHERE THEY LANDED UNEVENTFULLY. DURING TROUBLESHOOTING, MAINTENANCE FOUND A CRACKED LT HYDRAULIC MANIFOLD PUMP PRESSURE HOSE (P/N: AE1011923H0152). THE HOSE WAS REPLACED WITH NEW; LEAK AND OPERATIONAL CHECKS WERE NORMAL. THE AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR AWKA20190104001
SMOKE/FUMES/ODORS/SPARKS · 2018-09-15 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 13,058 hrs · 6,482 cycles

WHILE EN ROUTE, OPERATING ON A FERRY PERMIT FOR AN EXISTING, INTERMITTENT ELECTRICAL ANOMALY, THE FLIGHT CREW SMELLED ELECTRICAL "SMOKE" WHILE CLIMBING THROUGH FL380. THE FLIGHT CREW DONNED THEIR O2 MASKS AND DECLARED AN EMERGENCY. THE AIRCRAFT LANDED UNEVENTFULLY IN SLC. MAINTENANCE WAS CONTRACTED TO INSPECT AND REPAIR THE AIRCRAFT. AN EXTENSIVE INSPECTION OF NUMEROUS ITEMS AND SYSTEMS WAS PERFORMED AND NO ANOMALIES WERE FOUND. THE AIRCRAFT WAS SUBSEQUENTLY RELEASED WITH NO FURTHER ISSUES NOTED.

Source: SDR AWKA2018100902
FALSE WARNING · 2016-03-08 Matched by certificate designator
ATA 3620

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 10,504 hrs · 5,315 cycles

WHILE ON DEPARTURE, & CLIMBING THROUGH 5000’, THE FLIGHT CREW RECEIVED A RED, RT PYLON BLEED LEAK, CAS MSG. THE CREW RAN THE CHECKLIST & DECLARED AN EMER. THE DECISION WAS MADE TO DIVERT, WHERE THEY LANDED WITHOUT INCIDENT. NO BLEED AIR LEAKS WERE FOUND DURING ENG GND RUNS. HOWEVER OUT OF PRECAUTION, BOTH TEMP SENSORS, PN S101816PG, WERE REPLACED WITH NEW ON THE RT PYLON. ENG GND RUN LEAK & OPERATIONAL CHECKS WERE NORMAL. ACFT WAS RETURNED TO SERVICE.

Source: SDR AWKA20160310001
FLT CONT AFFECTED · 2016-01-27 Matched by certificate designator
ATA 2730

Part: BEARING — CORRODED (RT ELEVATOR) · airframe 10,382 hrs · 5,257 cycles

DURING CLIMB OUT, THE FLIGHT CREW NOTED AT SEVERAL ALTITUDE CHANGES. WHILE PULLING THE CONTROL YOKE BACK TO CLIMB & ALSO MOVING THE YOKE FWD TO CAPTURE THE ASSIGNED ALTITUDE THAT THERE WAS CONSIDERABLE ROUGHNESS FELT IN THE CONTROL YOKE. ALSO, THEY OBSERVED THE YOKE DISPLAYING A JERKING MOTION DURING CLIMB WITH THE AUTO PILOT ENGAGED. AFTER DISCUSSING THE ISSUE WITH MX CONTROL, THE DECISION WAS MADE TO DIVERT, WHERE THEY LANDED UNEVENTFULLY. UPON TROUBLESHOOTING, MX TECHNICIANS FOUND CORROSION ON THE RT ELEVATOR TORQUE TUBE UPPER BEARING & A FAILED LOWER BEARING. THE UPPER BEARING WAS CLEANED & RE-INSTALLED, WHILE THE LOWER BEARING, PN MS27648-16, WAS REPLACED WITH NEW. OPERATIONAL CHECKS PERFORMED, WITH NO DEFECTS NOTED. ACFT WAS RETURNED TO SERVICE.

Source: SDR AWKA7500127
OTHER · 2015-10-31 Matched by certificate designator
ATA 5610

Part: WINDSHIELD — CRACKED (COCKPIT) · airframe 10,113 hrs · 5,130 cycles

CLIMBING THROUGH 20,000 FEET, THE RT FWD SIDE WINDSHIELD SHATTERED. DECLARED AN EMER, DESCENDED TO 10,000 FEET & ELECTED TO DIVERT.

Source: SDR AWKA20151104001
FLUID LOSS; WARNING INDICATION · 2009-09-07 Matched by certificate designator
ATA 2910

Part: LINE — RUPTURED (HYDRAULIC SYS) · airframe 3,777 hrs · 2,045 cycles

WHILE CLIMBING-OUT, THE FLIGHT CREW SELECTED THE LANDING GEAR HANDLE TO THE (UP) POSITION. AS THE LANDING GEAR BEGAN TO TRANSITION, A BANG WAS HEARD FOLLOWED BY A LOSS OF THE A SYSTEM HYD FLUID. THE CREW ELECTED TO DECLARE AN EMERGENCY AND RETURN TO DEPARTURE. AN EMERGENCY GEAR EXTENSION WAS SUCCESSFULLY PERFORMED AND THE ACFT LANDED WITHOUT INCIDENT. MX INSP OF THE ACFT REVEALED THAT THE NOSE WHEEL CENTERING HYD PRESSURE LINE HAD FAILED RESULTING IN THE LOSS OF THE A SYSTEM HYD PRESSURE AND FLUID. THE HYD LINE WAS REPLACED WITH AN IMPROVED DESIGN HOSE.

Source: SDR AWKA750907