Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
9 reports on file, 1995-06-23 – 1997-09-30.
Part: SLIDE — BROKEN (L3 DOOR)
THE L3 DOOR EMERGENCY SLIDE PACK FULLY DISENGAGED FROM THE DOOR BUT DID NOT DEPLOY DURING ROUTINE OPERATIONAL CHECK. FOUND BOTH PRIMARY RELEASE CABLE PAWL PLATES BROKEN. REF MM 25-61-01 PAGE 409/410 DETAIL E. REPLACED SLIDE.
Part: LIGHT — INOPERATIVE (CABIN)
ON CABIN CHECK FOUND LEFT PATH LIGHT AT SEATS 35, 25, 21 INOP AND COVER MISSING. INSTALLED COVERS AND BULBS, OPS OK.
Part: CABLE — BROKEN (PAX DOOR)
DURING MID VISIT, THE L3 DOOR FAILED TO OPERATE IN THE EMERGENCY MODE. FOUND LOCK PIN CABLE BROKEN. REPLACED SAME PER MM 52-12-27.
Part: SWITCH PANEL — FAILED (COCKPIT)
ON GROUND, WASTE/WATER PANEL AFT 1 AND AFT 2 SWITCH LIGHT SHORTED OUT CAUSING FLAME AND SMOKE. USED HALON BOTTLE, SWITCH 217201153 FAULTED. REPLACED PANEL (P/N 3170001240).
Part: WIRE — BURNED (EXTERNAL POWER)
DURING SWITCH OVER FROM EXT PWR TO APU PWR TOTALLY LOST ALL ELECTRICAL POWER. CHECK FOUND EXT PWR RLY 2441-K1 BURNED AND ALL 6 FEEDER WIRES FROM RECEPT AT RELAY BURNT.
Part: CONTROL VLV — FAILED (RT MLG WW)
LOSS C-SYS HYD QTY IMMEDIATELY AFTER LANDING GEAR LOWERED. REPLACED LANDING GEAR PHASE CONTROL VALVE, OPERATED LANDING GEAR AND OPS CKS GOOD.
Part: POWER PACK — INOPERATIVE (L2 DOOR)
EMERGENCY EXIT SIGNS AND EXTERIOR LIGHT NEAR L2 DOOR INOP. REMOVED AND REPLACED EMERGENCY POWER PACK PER MM, OPS CHECKS GOOD PER MM.
Part: POWER SUPPLY — INOPERATIVE (CABIN)
ON LAYOVER, FOUND MID CABIN EMERGENCY LIGHTS INOP. REPLACED EMERGENCY LIGHT POWER SUPPLY, CHECKS GOOD.
Part: CHILLER UNIT — FAILED (FWD GALLEY)
DURING CRUISE, HAD SMOKE ODOR IN F/C GALLEY WITH C/B FOR CHILLER POPPED. CHILLER WAS REPLACED, OPERATION NORMAL.