N756DR

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

33 reports on file, 1995-02-20 – 2000-10-02.

SMOKE/FUMES/ODORS/SPARKS · 2000-10-02 Matched by certificate designator
ATA 2330

Part: VIDEO UNIT — ODOR (CABIN) · airframe 80,934 hrs · 16,444 cycles

ELECTRICAL SMELL IN CABIN DUE TO VIDEO PROJECTOR. REPLACED VIDEO PROJECTOR.

Source: SDR DLL19001930
FALSE WARNING · 2000-09-06 Matched by certificate designator
ATA 7930

Part: SWITCH — DEFECTIVE (NR 3 ENGINE) · airframe 80,648 hrs · 16,337 cycles

NR 3 ENG OIL FILTER PRESSURE ILLUMINATED WITH ASSOCIATED ENG VIB FILTER PRESS LIGHT. ALL ENGINE INDICATIONS WERE NORMAL. ENGINE SHUTDOWN IN ACCORDANCE WITH POM. REPLACED SCAVENGE AND MAIN FILTER AND CHECKED CHIP DETECTORS, SATISFACTORY. REPLACED SCAVENGE DIFF PRESS SWITCH (FOUND SWITCH BAD). RAN ENG AND LEAK CHECK GOOD 79-00-00 CONF 2. REPLACED DIFF PRESSURE SWITCH, OPERATIONAL CHECK GOOD ON ENG RUN.

Source: SDR DLL19001713
OTHER · 2000-04-13 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 79,525 hrs · 15,896 cycles

DURING LAYOVER, FOUND L1 EXT EMERGENCY LIGHT INOP. REPLACED POWER SUPPLY, CHECKS GOOD PER MM.

Source: SDR DLL19000704
OTHER · 2000-02-07 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 679)

THE FUSELAGE BELLY SKIN WAS FOUND WITH A CRACK DUE TO CORROSION AT FS 679 JUST TO THE RIGHT OF THE BL 0 SPLICE (STRINGER 33). THE CORRODED AREA OF SKIN WAS CUT OUT WITH A 13 X 7 CUTOUT AND REPAIRED WITH AN EXTERNAL ALUMINUM DOUBLER PER ER/A 369244-14, REV A.

Source: SDR DLL19000275
Earlier reports · 1995–1999 · 29 reports

1999

NO TEST · 1999-06-13 Matched by certificate designator
ATA 3350

Part: SOCKET — DAMAGED (ROW 2C)

EMERGENCY ESCAPE PATH LIGHT DID NOT ILLUM WHEN TESTED. REPLACED SOCKET, NOW OPS NORMAL.

Source: SDR DLL19991336

1998

OTHER · 1998-10-31 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1745-1776)

THE FUSELAGE SKIN WAS FOUND WITH THREE AREAS OF CORROSION BETWEEN FS 1745 AND 1776 BETWEEN S-31 AND 33. THE CORROSION REMOVAL RESULTED IN THREE CUTOUTS SIZED 6 X 5, 5 X 4 AND 2 X 2. THE SKIN CUTOUTS WERE REPAIRED WITH A SINGLE EXTERNAL ALUMINUM DOUBLER AND TRIPLER REPAIR PER ER/A 365961-14, REV A.

Source: SDR DLL19982267
FLUID LOSS · 1998-05-10 Matched by certificate designator
ATA 2761

Part: GASKET — TORN (NR 5 SPOILER ACT)

LOSS OF C-SYS HYD FLUID DUE TO RT NR 5 SPOILER HYD LK. LANDING GEAR WAS MANUALLY EXTENDED. REPLACED SEAL ON NUMBER 5 SPOILER ACTUATOR.

Source: SDR DLL19980988
OTHER · 1998-03-09 Matched by certificate designator
ATA 5711

Part: SPAR — CRACKED (LT/RT WING)

DURING INSPECTION OF THE LT AND RT RS UPPER CAP FASTENER HOLES PER EO 7-59089-3 SEVERAL CRACK INDICATIONS WERE FOUND ON THE SPARS. THE REAR SPAR MODIFICATION WILL NOW BE ACCOMPLSIHED ON THIS AC. THIS REPAIR DOCUMENTS THE DEVIATIONS (REPAIRS) NEEDED TO COMPLETE THE MOD. REPAIRED PER ERA 331368-14AD.

Source: SDR DLL19980543
NO TEST · 1998-03-02 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

EMERGENCY LIGHT BATTERY PACK DEAD. NO VOLTAGE OUTPUT.

Source: SDR DLL19980497
NO TEST · 1998-03-02 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

BATTERY PACK DEAD DUE TO PWR SUPPLY VOLTAGE INOP.

Source: SDR DLL19980498
NO TEST · 1998-01-31 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

NR 5 BATT PACK (EMERGENCY LIGHT) WILL NOT HOLD CHARGE. REPLACED POWER SUPPLY.

Source: SDR DLL19980273

1997

OTHER · 1997-12-17 Matched by certificate designator
ATA 5754

Part: SKIN — CRACKED (NR 4 LE SLAT)

LT WING NR 4 SLAT UPPER SKIN CRACKED 4PLS SRM REPAIR REF 57-51-00 FIG808 MAJOR REPAIR.

Source: SDR DLL19972665
NO TEST · 1997-10-31 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

LT AFT EXT EMERGENCY LIGHT INOP. REPLACED PWR SUPPLY, CKS GOOD.

Source: SDR DLL15972218
WARNING INDICATION · 1997-08-29 Matched by certificate designator
ATA 3244

Part: TIRE — FAILED (MLG)

FLAP/SLAT LOCK LIGHT ILLUM ON TAKEOFF. FLAP ASSY LOCKED AT 1 AND 14. FUEL DUMPED AND RETURN TO JFK. FOUND MAIN TIRE FAILED AND RESULTED IN DAMAGE TO FLAP. REPLACED TIRE AND REPAIRED FLAP.

Source: SDR DLL15971703
NO TEST · 1997-05-24 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING TEST OF EMERGENCY LIGHTS THE AFT CABIN SECTION OF EMERGENCY LIGHTS DID NOT REMAIN ON LONG ENOUGH. THE POWER SUPPLY AND BATTERY PACK WERE REPLACED AND THE SYSTEM CHECKED NORMALLY.

Source: SDR DLL15971002
NO TEST · 1997-05-23 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING TEST OF THE EMERGENCY LIGHTS THE AFT CABIN EMERG LIGHTS DID NOT REMAIN ON LONG ENOUGH. THE BATTERY PACK AND POWER SUPPLY WERE REPLACED AND THE LIGHTS CHECKED NORMALLY.

Source: SDR DLL15971003
OTHER · 1997-02-03 Matched by certificate designator
ATA 5711

Part: SPAR — CRACKED (RT WING REAR)

DURING ACCOMPLISHMENT OF EO 7-59089-3, SEVERAL HOLES IN RT WING REAR SPAR WERE FOUND CRACKED IN UPPER SPAR CAP AND TO THE SPAR WEB BETWN IWS 293-346. THE HOLES WERE COLD WORKED AND REINSPECTED PER INSTRUCTIONS OF EO 7-59089-3.

Source: SDR DLL15970293
NO TEST · 1997-01-31 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

DURING LAYOVER CHECK, FOUND FIRST CLASS EMERGENCY LIGHTS WOULD NOT REMAIN ON FOR DURATION OF TEST. THE POWER SUPPLY AT 1-R WAS REPLACED AND THE LIGHTS CHECKED NORMAL.

Source: SDR DLL15970195
OTHER · 1997-01-28 Matched by certificate designator
ATA 5330

Part: SKIN — CORROSION (FS 856)

FUSELAGE SKIN CORRODED AT FS 856 BETWEEN SRR 33 AND STR 34. CUT OUT DAMAGE: 6 INCHES BY 6 INCHES. THE CENTERLINE 0.020 INCH DOUBLER WAS DAMAGED AND WILL BE REPAIRED PER L1011 SRM.

Source: SDR DLL15970166
OTHER · 1997-01-27 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (BS 983-1212)

CENTER WING UPPER SURFACE BETWEEN RBL AND LBL 94.5 AND 115.8 WAS FOUND WITH CORROSION. MOST CORROSION WAS FOUND IN THE STR-TO-SKIN FASTENERS BETWEEN FRONT SPAR FS 983 TO REAR SPAR AT FS 1212. DAMAGE WAS CLEANED WITH DEPTHS RANGING FROM 0.003 INCH TO 0.081 INCH.

Source: SDR DLL15970167
OTHER · 1997-01-27 Matched by certificate designator
ATA 5711

Part: SPAR — CRACKED (LT WING REAR)

SEVERAL HOLES IN THE LT WING REAR SPAR WERE FOUND CRACKED DURING INSPECTION PER EO 7-59089-3. ER/A REWORKED HOLES, AND INSTALLED REPAIR ANGLES.

Source: SDR DLL15970297
OTHER · 1997-01-17 Matched by certificate designator
ATA 5330

Part: SKIN — CORROSION (BS 943)

EXTENSIVE CORROSION WAS FOUND IN THE MEXC DOOR SURROUND TRIPLER AND FUSELAGE SKIN AT THE LOWER, FORWARD CORNER OF THE DOOR CUTOUT. THE CORROSION WAS FOUND BETWEEN THE TRIPLER AND THE SKIN AT FS 943 JUST OUTBOARD OF STR 28. DUE TO THE SEVERITY OF THE CORROSION, THE LOWER HALF OF THE TRIPLER AND SECTION OF THE FUSELAGE SKIN REQUIRE REMOVAL. THE MESC DOOR SURROUND TRIPLER IS MADE FROM .220 THICK 7075-T6 CLAD PLATE. THE FUSELAGE SKIN IS MADE FROM .068 THICK 2024-T3 CLAD SHEET. THE BONDED DOOR SURROUND DOUBLER IS MADE FROM .032 THICK 2024-T3 CLAD SHEET.

Source: SDR DLL15970256
OTHER · 1997-01-15 Matched by certificate designator
ATA 5312

Part: BULKHEAD FRAME — CRACKED (AFT PRESS DOME)

THE AFT P-DOME ZEE FRAME WAS DISCOVERED CRACKED AT STR 33 DUE TO CORROSION. THIS ER/A GIVES AUTHORIZATION TO MTC TO SPLICE IN A NEW SECTION OF ZEE FRAME FROM THE EXISTING FACTORY SPLICE AT STR 29 TO STR 37. THE FRAME IS MADE FROM .050 THICK 7178-T6 AL SHEET.

Source: SDR DLL15970257

1996

NO TEST · 1996-11-16 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

DURING L/O CK, FOUND AFT CABIN EMERGENCY LIGHTS WOULD NOT REMAIN ON LONG ENOUGH DURING TEST OF THE EMERGENCY LIGHTS. REPLACED POWER SUPPLY AT R-3 DOOR AND THE LIGHTS CK NORMAL.

Source: SDR DLL15962527
NO TEST · 1996-10-24 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

FIRST CLASS EMERGENCY LIGHTS WERE DISCOVERED TO REMAIN ON FOR AN INSUFFICIANT AMOUNT OF TIME DURING A TEST OF EMERGENCY LIGHTING SYSTEM. TEST WAS REQUIRED AS A LAYOVER CHECK ITEM. THE EMERGENCY LIGHT POWER SUPPLY AT THE R1 CABIN ENTRANCE DOOR WAS REPLACED AND THE SYSTEM THEN OPERATED NORMALLY.

Source: SDR DLL15962390
NO TEST · 1996-08-11 Matched by certificate designator
ATA 3350

Part: TRACK — DAMAGED (CABIN)

SECTION OF EMERGENCY LIGHT TRACK INOP RT SIDE MID CABIN. FOUND WIRE BROKEN. REPAIRED WIRE, CHECKS GOOD.

Source: SDR DLL15961870
OTHER · 1996-02-06 Matched by certificate designator
ATA 5753

Part: SKIN — GOUGED (NR 1 FLAP VANE)

UPON ROUTINE INSPECTION, A 12 INCH GOUGE WAS FOUND ON I/B END TOP SKIN. REPAIRED AS PER SRM 57-53-00, FOR LT NR 1 FLAP VANE.

Source: SDR DLL15960459

1995

NO TEST · 1995-11-30 Matched by certificate designator
ATA 3350

Part: EEL WIRE — BROKEN (CABIN)

ON LAYOVER, FOUND EMERGENCY AISLE LIGHTS INOP RT AISLE IN COACH. FOUND BROKEN WIRE AT 26J. REPAIRED WIRE, OPS CHECKS GOOD.

Source: SDR DLL15954581
NO TEST · 1995-09-27 Matched by certificate designator
ATA 3350

Part: EEL POWER SUPPLY — INOPERATIVE (CABIN)

DURING TEST, R-2 EMERGENCY LIGHT POWER SUPPLY INOP. REPLACED POWER SUPPLY, CHECKS OK.

Source: SDR DLL15953840
FLUID LOSS; WARNING INDICATION · 1995-09-09 Matched by certificate designator
ATA 3233

Part: ACTUATOR — CRACKED (LT MLG)

THE C-HYDRAULIC SYSTEM FAILED WHEN GEAR EXTEND FOR LANDING. FOUND MLG ACTUATOR HOUSING CRACKED. REPLACED MLG ACTUATOR PER MM 32-32-01, OPS AND LEAK CHECK OK.

Source: SDR DLL15953653
WARNING INDICATION · 1995-09-09 Matched by certificate designator
ATA 3233

Part: ACTUATOR — BROKEN (LT MLG)

ON APPROACH, WHEN GEAR LOWERED GOT IN TRANS AND LT GEAR DOOR LIGHTES, NO GREEN LIGHT FOR LEFT GEAR. CYCLED GEAR GOT NORMAL INDICATION, LANDED CVG. FOUND LEFT MLG JURY BRACE ACTUATOR BROKEN. REPLACED SAME, OPERATION NORMAL.

Source: SDR DLL15953663
OTHER · 1995-02-27 Matched by certificate designator
ATA 5522

Part: PANEL — CRACKED (RT ELEV)

RT ELEVATOR OUTBD LIP PNL CRACKED PASSED STOP DRILL HOLE JUST INBD OF OUTBD STATIC WICK UPPER SURFACE. REMOVED DAMAGE AND INSTALLED REPAIR PER SRM 55-22-00 FIG 802. DAMAGE FOUND AT LETTER CHECK.

Source: SDR DLL15950858
OTHER · 1995-02-20 Matched by certificate designator
ATA 5755

Part: HINGE LUGS — CRACKED (LT SPOILER)

E.O. 7-68609-12 OPN. 103 FOUND CRACKED INBETWEEN I/B SPOILER HINGE LUGS OF NR 2 SPOILER. DAMAGE FOUND AT LETTER CHECK. REPAIRED PER SRM 57-22-00 FIG 806.

Source: SDR DLL15950794