3 reports on file, 2016-06-19 – 2018-03-08.

WARNING INDICATION · 2018-03-08 Matched by certificate designator
ATA 2910

Part: NOT REPORTED — UNKNOWN (HYDRAULIC SYS) · airframe 7,322 hrs · 4,388 cycles

WHEN AIRCRAFT DEPARTED CVG (FOR A MAINTENANCE TEST FLIGHT) AND AFTER GEAR WAS PUT IN THE RETRACT POSITION, THE "A" SIDE VOLUME READ 17%. DECLARED EMERGENCY AND RETURNED TO CVG. LANDING AND ROLLOUT WERE UNEVENTFUL.

Source: SDR CVGA20180312001
OTHER · 2017-06-05 Matched by certificate designator
ATA 5610

Part: WINDOW — FAILED (COCKPIT) · airframe 6,784 hrs · 4,064 cycles

WHILE IN CLIMB TO FL410, RT SIDE WINDOW SHATTER PASSING FL 340. STOPPED THE CLIMB AND DECLARED AN EMERGENCY. DESCENDED WITH NO ISSUES.

Source: SDR CVGA20170608001
WARNING INDICATION · 2016-06-19 Matched by certificate designator
ATA 2130

Part: SEAL — CONTAMINATED (CARGO DOOR) · airframe 5,990 hrs · 3,559 cycles

ENROUTE, JUST PRIOR TO NUCAR INTERSECTION, BAGGAGE DOOR SEAL, CAS MESSAGE ILLUMINATED, FOLLOWED BY CABIN ALTITUDE, CAS MESSAGE SHORTLY THEREAFTER. RAN BOTH ABNORMAL PROCEDURES AND INITIATED AN EMERGENCY DECENT. DECLARED AN EMERGENCY WITH ATC. WE MADE THE DECISION TO DIVERT. LANDED WITHOUT FURTHER INCIDENT. INSPECTED BAGGAGE DOOR SEAL, CHECK GOOD. RAN APU AND PERFORMED BAGGAGE COMPARTMENT ISOLATION SYSTEM FUNCTIONAL CHECK, CHECK GOOD. FOUND NO BAGGAGE DOOR SEAL LEAKS. DISCONNECTED BAGGAGE DOOR SEAL LINE AT DOOR. CONNECTED SERVICE AIR, FOUND EXCESSIVE WATER IN SYSTEM. PURGED AND EVACUATED SYSTEM. OPS CHECK GOOD. COMPLIED WITH BAGGAGE COMPARTMENT ISOLATION SYS FUNCTIONAL CHECK. NO FAULT FOUND.