N760GT
Registered owner: UMB BANK NA TRUSTEE, UT (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
9 reports on file, 2024-08-26 – 2026-10-12.
Part: SEAT BELT — NO DISCREPANCY (ZONE 200) · airframe 10,674 hrs · 1,319 cycles
CAPTAIN`S SEAT BELT WONT LATCH. PERFORMED INSPECTION OF SEAT BELT & SHOULDER HARNESS IAW AMM 25-11-00. NO DEFECTS NOTED, OPS CHKD GOOD IAW CMM 25-11-38.
Part: FLASHLIGHT — INOPERATIVE (ZONE 200) · airframe 10,275 hrs · 1,269 cycles
CAPTS FLASHLIGHT INDICATOR LIGHT INOP. TRANSFER TO DMI 259256 PER MEL 25-64-02 CAT C. REMOVED AND REPLACED NEW CAPTAIN'S FLASHLIGHT, OPS CHECK NORMAL PER AMM 25-64-01/201.
Part: FLASHLIGHT — MALFUNCTIONED (ZONE 200) · airframe 8,831 hrs · 1,085 cycles
CA FLASHLIGHT GREEN LIGHT FLASHING. PERFORMED FLASHLIGHT TEST PER AMM 25-64-51 & OPS CHECK GOOD.
Part: FLASHLIGHT — FAULTED (ZONE 200) · airframe 5,260 hrs · 667 cycles
CAPT SIDE EMERGENCY FLASHLIGHT GREEN LIGHT FLASHING MULTIPLE TIMES PER SECOND. R & R CAPT FLASHLIGHT IAW AMM 25-64-01. OPS CHECK GOOD.
Part: SHUTOFF VALVE — FAULTED (RT ENGINE) · airframe 4,732 hrs · 603 cycles
BLEED OFF ENG R EICAS WITH APU ALREADY ON DEFERRAL. REPLACED RH ENG HPSOV PER AMM 36-11-07 & IPC 36-11-02-0113. OPS CHECK NORMAL. PERFORMED ENG RUNS & ACCOMPLISHED ENG AIR SUPPLY OPS TEST PER AMM 36-10-00. OPS CHK GOOD. NO FAULTS NOTED. ALSO, R & R PRSOV CONTROLLER IAW AMM 36-11-15/401. OPS CHECK NORMAL. NO DEFECTS NOTED. REF AIPC 36-11-18-01B.
Part: FLASHLIGHT — INOPERATIVE (ZONE 200) · airframe 3,530 hrs · 459 cycles
CAPT & FO EMERGENCY FLASHLIGHTS INOP. TRANSFER TO DMI # 231148 PER MEL 25-64-02C, CAT C, DUE 31MAY25. LP 1999369 M3, ORD, 27MAY25: REPLACED FLASHLIGHTS IAW AMM 25-64-01. OPS CHECK GOOD.
Part: SMOKE DETECTOR — FALSE ACTIVATION (ZONE 200) · airframe 2,786 hrs · 370 cycles
SMOKE CREW REST F/D EICAS MESSAGE.(<P>CREW RESET SMOKE DETECTOR C/B RESET AND OPERATIONAL CHECK SATISFACTORY IAW AMM 26-14-10.</P>)
Part: SEAL — BROKEN (EVAS) · airframe 2,113 hrs · 286 cycles
CAPT SIDE EVAS RED SEAL FOUND BROKEN.(<P>TRANSFER TO DMI 224765 PER MEL 25-64-04 CAT D. PLACARD INSTALLED.&NBSP;</P> / <P>25JAN25 - ORD - 1904731 - ITEM 5 - REPLACED CAPTAIN EVAS RED SEAL PER ATLAS TASK CARD C-25-099-17-01. THIS CLEARS DMI 224765. PLACARDS REMOVED</P>)
Part: OIL FILTER — WARNING MESSAGE (LT ENGINE) · airframe 62 hrs · 28 cycles
ENG OIL FILTER L STATUS.(<P>PERFORMED FIM TASK 79-21 TASK 819. PERFORMED PROCEDURE E (1A), (1B), (1C) & (1D).</P> / <P>PERFORMED ENGINE FLUSH PER AMM 12-22-01. REPLACED LH ENG OIL FILTER PER AMM 79-21-07 & IPC 79-21-03-03. PERFORMED ENGINE RUN PER AMM TASK 71-00-00-800-835-H00 & 71-00-00-700-805-H01.</P> / <P>PERFORMED DMS SENSOR, SUMP A, SUMP B & SUMP C SCREENS INSPECTION PER AMM 79-00-00-200-805-H01. NO DEFECTS NOTED. LEAK CHECK GOOD.&NBSP;&NBSP;</P>)