N764JR

SHORT BROS PLC SD3-60 VARIANT 200 · 1991 · Fixed-wing multi-engine · 2 engines · 41 seats · Valid Registration

Registered owner: ACC INTEGRATED SERVICES INC, WI (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
AIR CARGO CARRIERS, LLC. (DATA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2011-09-17 – 2022-04-06.

SMOKE/FUMES/ODORS/SPARKS · 2022-04-06 Matched by certificate designator
ATA 1420

Part: WINDSHIELD — IMPROPER PART (ZONE 200) · airframe 23,209 hrs · 21,140 cycles

DURING CRUISE THE RIGHT WINDSHIELD HEAT CIRCUIT TERMINAL BOARD AT THE BASE OF THE WINDSHIELD STARTED SMOKING AND WINDSHIELD HEAT WAS INOPERATIVE. MAINTENANCE REPLACED P2 TERMINAL BOARD HARDWARE WITH CORRECT AN508-10-5 AND MS35333-107 HARDWARE IAW WINDSHIELD MANUAL. OPERATIONAL CHECK GOOD.

Source: SDR DATA2022040600001
PARTIAL RPM/PWR LOSS · 2021-07-07 Matched by certificate designator
ATA 6122

Part: GOVERNOR — INOPERATIVE (NR 2 PROPELLER) · airframe 22,915 hrs · 20,846 cycles

AT 10,000 MSL ON CLIMB THE NUMBER 2 PROPELLER RPM SLOWLY STARTED TO DECREASE. AN ATTEMPT TO FORWARD THE PROPELLER LEVER CAUSED THE RPM DECREASE TO CONTINUE. THE ENGINE WAS SHUT DOWN IN FLIGHT, AN EMERGENCY WAS DECLARED AND THE CREW RETURNED THE AIRCRAFT TO THE DEPARTURE AIRPORT WHERE AN UNEVENTFUL SINGLE ENGINE LANDING WAS MADE. MAINTENANCE TROUBLESHOT THE PROBLEM AND REPLACED THE PROPELLER GOVERNOR. NO FURTHER DEFECTS NOTED.

Source: SDR DATA07092021001
PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2018-06-01 Matched by certificate designator
ATA 7200

Part: ENGINE — POWER LOSS (RIGHT) · airframe 21,573 hrs · 19,219 cycles

ON A 5 MILE FINAL WITH AN RJ IN TRAIL BY 3 MILES, PULLED POWER BACK TO IDLE. RIGHT ENGINE MADE A POPPING NOISE AND STARTED FLUCTUATING IN TORQUE. P USHED BOTH POWER LEVERS UP TO SEE IF THE TORQUE WOULD STABILIZE, THAT FAILED , DECIDED TO SECURE THE RIGHT ENGINE. DECLARED AN EMERGENCY AND LANDED. NO OTHER ISSUES ENCOUNTERED.

Source: SDR DATA20180604101
OVER TEMP; WARNING INDICATION · 2017-02-03 Matched by certificate designator
ATA 7200

Part: ENGINE — OVERTEMP (NR 1) · airframe 21,096 hrs · 18,842 cycles

AFTER TAKE OFF, DURING NORMAL CLIMB, CLIMB CHECKLIST ACCOMPLISHED, NR 1 ENGINE ITT WAS NOTED TO BE HIGH AT 840°- OIL PSI 125 - OIL TEMP 110°. POWER WAS REDUCED ON AFFECTED ENGINE, BUT CONDITION PERSISTED DICTATING A PRECAUTIONARY NR 1 ENGINE SHUTDOWN AND RETURN TO POINT OF DEPARTURE. A SINGLE ENGINE RETURN, APPROACH AND LANDING WAS ACCOMPLISHED.

Source: SDR DATA2017020301
FLUID LOSS; ENGINE STOPPAGE; WARNING INDICATION · 2011-09-17 Matched by certificate designator
ATA 7200

Part: BOLT — FAILED (ENGINE) · airframe 19,806 hrs · 17,904 cycles

RT SIDE ENGINE EXPERIENCED A LOW OIL PRESSURE LIGHT 1.5 HOURS INTO MISSION AND SUBSEQUENT PRESSURE LOSS. ENGINE WAS SHUTDOWN IN FLIGHT AND ACFT DIVERTED. THE ENGINE WAS RECEIVED AT THIS FACILITY FOR INVESTIGATION. THE PROPELLER SHAFT WAS HARD TO TURN AND A GRINDING NOISE WAS HEARD. THE CHIP DETECTOR WAS REMOVED AND FOUND IT WAS COMPLETELY ENCASED IN METAL CHIPS. THE POWER SECTION WAS REMOVED AND DISASSEMBLED. UPON REMOVAL OF THE 1ST STAGE CARRIER IT WAS DISCOVERED THAT THE HEAD WAS MISSING FROM ONE OF THE 6 INSTALLED MS 9490-34 BOLTS THAT HOLD THE SPLINE ADAPTER PLATE TO THE CARRIER. THE SUBJECT BOLTS AND FAILURES ARE ADDRESSED IN SB 14444 AND WAS ALSO INVESTIGATED BY THE TRANSPORT SAFETY BUREAU, AO-2010-006.

Source: SDR DATR001632