N78009

BOEING 777-224 · 1999 · Fixed-wing multi-engine · 2 engines · 400 seats · Valid Registration

Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

GLOBE GC-1B No injuries Part 91 — operator not named in the NTSB record
Source: NTSB case MKC68D0142
GLOBE SWIFT GC1B No injuries Part 91 — operator not named in the NTSB record
Source: NTSB case UNK64X2619

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

81 reports on file, 1999-10-19 – 2026-08-27.

NO TEST · 2026-08-27 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 128,557 hrs · 13,186 cycles

EMERGENCY LIGHTS AROUND DOOR 3R GOES OFF AFTER FEW MINUTES BEING TESTED. TROUBLESHOOTED PER FIM 33-51 TASK 806 AND FOUND EMERGENCY POWER SUPPLY M33401 WITH BATTERY DISCHARGED. REPLACED BATTERY PACK OF POWER SUPPLY M33401 PER AMM TASK 33-51-06-960-802. LIGHTS OPS TESTED SATISFACTORILY.

Source: SDR CALA2026083119061
OTHER · 2026-07-13 Matched by certificate designator
ATA 5753

Part: SEAL — MISSING (ZONE 500) · airframe 127,886 hrs · 13,112 cycles

LEFT INBORD FLAPERON SEAL MISSING ON ARR. CLEATED CDL LOG PG 9586033. NO OTHER DAMAGE NOTED. LEFT FLAPERON INBOARD SEAL MISSING 4 FOOT ADD PIC INFORMATION FOR PDA PAGE REF LP9586114 PREVIOUS PDA 3 LP 9586114 WRONG, SHOULD READ PDA 2 REF LP 9586228 4 FOOT OF SEAL MISSING ON ARR, REQUEST CDL DEFERRAL ITEM PLACED ON CDL, SEAL NIS HND DISPATCH DESK: 56 NAME: TA DATE: 13-JUL-26- APPROVED CDL 57DE

Source: SDR CALA2026071617814
WARNING INDICATION · 2026-06-21 Matched by certificate designator
ATA 7230

Part: COMPRESSOR — STALLED (RT ENGINE) · airframe 127,737 hrs · 13,096 cycles

RIGHT ENG COMPRESSOR STALL AND EGT EXCEEDANCE AT V1 REVIEWED AHM DATA, FOUND EGT DATA PEAKED AT 138.5 FOR 6 SECS. REF AMM 71-00-00-200-814-G00 7.C.(2)(B) TAKEOFF AND MAX CONTINUOUS EGT FIG 603, 1038.5 FOR 6 SECS PUTS US IN AREA B AND DOES NOT REQ IMMEDIATE ENGINE CHANGE. AREA B REQ'S A BSI OF THE HPT. ALSO, REVIEWED AHM DATA FOR PREVIOUS EXCEEDANCES, NONE NOTED.

Source: SDR CALA2026070117512
WARNING INDICATION · 2026-06-19 Matched by certificate designator
ATA 7320

Part: HMU — FAULTED (NR 2 ENGINE) · airframe 127,737 hrs · 13,096 cycles

RIGHT ENGINE COMPRESSOR STALLED ON ROTATION NO EXCEEDENCES. PERFORMED FAULT ISOLATION NR 2 ENG IAW FIM 71-05, TASK 807, STEPS A - E, NO DEFECTS NOTED. NR 2 ENGINE BORESCOPE PLUGS REMOVAL & INSTALL CONTINUED FAULT ISOLATION PROCEDURE ON FIM 71-05, TASK 807, STEP E (1) THRU (B) 2), ENG CONTROL RT OR ENG EEC C1 R MESSAGES NOT PRESENT. ALSO ON EXISTING SCHEDULED MAINTENANCE TASK SCREEN ENG EEC C2 R MSG NOT PRESENT. CONTINUED FAULT ISOLATION PROCEDURE ON FIM 71-05 TASK 807 - STEP E.(2). IP CHECK VALVE FOUND TO BE SERVICABLE. R & R NR 2 ENGINE HMU. CONTINUED WITH FIM 71-05 TASK 807 FROM STEP E.(6)(A). NO STATUS OR MX MESSAGES PRESENT. R & R NR 2 ENGINE HMU IAW AMM UP TO AND INCLUDING STEP. I. (11)(G)1). .

Source: SDR CALA2026062417313
NO TEST · 2026-06-17 Matched by certificate designator
ATA 3350

Part: CHARGER — FAULTY (ZONE 200) · airframe 127,708 hrs · 13,091 cycles

EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - EMERGENCY LIGHTS BETWEEN ROW 22 AND DOOR 3 RH DOES NOT GO ON. POWER SUPPLY REPLACEMENT IAW AMM 33-51-06-960-803. TEST OK.PARTS USED: 29-3351-3-0031,QTY :1

Source: SDR CALA2026061717167
NO TEST · 2026-02-17 Matched by certificate designator
ATA 5210

Part: BATTERY — INOPERATIVE (EPAS) · airframe 126,409 hrs · 12,953 cycles

EMERGENCY POWER ASSIST SYSTEM (EPAS) BATTERY - ELECTRICAL CHARGE CHECK (PED 1, 2, 3, 4) EPAS BATTERY ELECTRICAL CHARGE CHECK - EPAS BATTERY DOESNT BLINK. REQUIRES BATTERY REPLACEMENT REPLACED 9V BATTERY PACK IAW AMM TASK 52-11-20-400-806-002.

Source: SDR CALA2026021713849
Earlier reports · 1999–2025 · 75 reports

2025

OTHER · 2025-09-07 Matched by certificate designator
ATA 2565

Part: SLIDE — NO DISCREPANCY (ZONE 800) · airframe 124,267 hrs · 12,737 cycles

SLIDE RAFT PRESSURE GAUGE NOT IN GREEN. THE PRESSURE INDICATOR NEEDLE IS IN THE GO BAND (GREEN).REF AMM TASK 52-11-22-200-801.

Source: SDR CALA2025091008706
FLUID LOSS · 2025-09-05 Matched by certificate designator
ATA 5610

Part: SEALANT — DETERIORATED (ZONE 200) · airframe 124,206 hrs · 12,730 cycles

WHILE PRESSURIZING AIRCRAFT TO LEAK CHECK CAPT WINDSHIELD FOUND 3 LOCATIONS LEAKING. STARTED TO REMOVE SEALANT AND REMOVED WINSHIELD WIPER. SEALANT DID NOT APPEAR TO BE FULLY CURED HAD A CRUMBLY TEXTURE AND SMELLED UNCURED. REMOVED OLD SEALANT, RETORQUED AND RESEALED CAPT WINDSHIELD REF AMM 56-11-01. SEALED AT 01:30. LEAK CHECK STILL REQUIRED AFTER SEALANT CURES. PRESSURIZED AIRCRAFT TO 2 DPSI NO LEAKS NOTED. OPS CK GOOD, AMM 56-11-01

Source: SDR CALA2025090508496
FLUID LOSS; WARNING INDICATION · 2025-09-04 Matched by certificate designator
ATA 8011

Part: STARTER — LEAKING (NR 1 ENGINE) · airframe 124,235 hrs · 12,734 cycles

OIL QTY LOW ENG 1. DROP TO ZERO IN FLT. LOSS OF 1 QT EVERY 20-25 MINS. REPLACED STARTER REF AMM 80-11-01. ACCOMPLISHED 10 MIN IDLE RUN NO EXTERNAL LEAKS NOTED.

Source: SDR CALA2025090808590
OTHER · 2025-07-13 Matched by certificate designator
ATA 3397

Part: CIRCUIT BREAKER — NO DISCREPANCY (ZONE 200) · airframe 123,567 hrs · 12,661 cycles

PULLED C/B H9 EMERGENCY LIGHTS DOOR 1L, H10 EMERGENCY LIGHTS DOOR 2R, H11 EMERGENCY LIGHTS DOOR 1R & 2L, H16 EMERGENCY LIGHTS DOOR 3L, H17 EMERGENCY LIGHTS DOOR 3R, H18 EMERGENCY LIGHTS DOOR 4L & 4R ON P11 FOR EPAS BATTERY REPLACEMENT. CLOSED C/BS H9, H10, H11, H16, H17, H18 ON P11 AFTER EPAS BATTERY REPLACEMENT.

Source: SDR CALA2025071706663
OTHER · 2025-07-02 Matched by certificate designator
ATA 5754

Part: SKIN — DENTED (ZONE 600 SLAT) · airframe 123,471 hrs · 12,650 cycles

FOUND DENT ON SLAT 13 DURING POST ARRIVAL WALK AROUND WIDTH 4", HEIGHT 1.5", DEPTH 0.085". NO LOOSE OR MISSING FASTERS. WITHIN 20" AND DENT DOES NOT CREASE ALONG UNDERLYING STRUCTURE. HFEC INSPECTION PERFORMED. ACCOMPLISHED ECRA 5740-03356 PART 1 INTERIM REPAIR.

Source: SDR CALA2025070306192

2024

OTHER · 2024-11-29 Matched by certificate designator
ATA 5410

Part: DOOR — MISSING (ZONE 400) · airframe 120,906 hrs · 12,398 cycles

PDA 2 #1 ENGINE RH INBOARD TR MID PANEL 416FR HINGE AND SMALL DOOR ASSY FOUND MISSING ON ARRIVAL SEE LP 3042567. MISSING COMPONENT APPROX 6X3 INCHES, METALLIC IN CONSTRUCTION. A/C LANDED ON RUNWAY 1R AND AIRPORT OPS ADVISES RUNWAY CHECKED NO DEBRIS WAS FOUND INSTALLED REPLACEMENT DOOR AND HINGE ON EXISTING PANEL REF SRM 51-40-02 INSTALLED RH INBOARD TR MID PANEL 416FR REF AMM 78-31-09. ADD EMP:U416528

Source: SDR CALA2024120201383
OTHER · 2024-11-26 Matched by certificate designator
ATA 2565

Part: SLIDE — UNKNOWN (ZONE 800) · airframe 120,838 hrs · 12,392 cycles

R2 PASSENGER DOOR WAS MADE SAFE AS INSTRUCTED IN AMM SUBTASK 52-11-26-860-001. INSTALLED SLIDE SAFETY PINS (2 EACH) ON DOOR R2. CORRECTION: REMOVED AND STOWED PINS (2 EACH). UNABLE TO PIN BOTTOM PIN DUE TO SLIDE NOT BEING DISARMED, IN REFERENCE TO AMM SUBTASK 52-11-26-860-001. RECONFIGURED DOOR R2 TO NORMAL POSITION. REVERSED AMM SUBTASK 52-11-26-860-001. C/B'S (2EACH) CLOSED. SWITCH IN ARM POSITION. PINS VERIFIED STOWED. ACP RII INSP OF DOOR 2 RH VERIFY DOOR CIRCUITS BREAKERS ARE IN, EPAS IS ARMED, DOOR LEVER IS IN THE DISARMED POSITION AND SAFTY PINS ARE STOWED IN THE POUCH. REF GMM 09-25-05.

Source: SDR CALA2024112801346
OTHER · 2024-11-25 Matched by certificate designator
ATA 5270

Part: WARNING LIGHT — UNKNOWN (ZONE 800) · airframe 120,825 hrs · 12,391 cycles

DOOR FLIGHT LOCK 2R EICAS STATUS #2 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT. DB PSEU 2 (R2) DB PSEU 2 (L2) ITEM ALREADY ON MEL. REFERENCE LOGPAGE 9967740 FOR MEL DDP PRIOR TO EACH FLIGHT.

Source: SDR CALA2024112701317
WARNING INDICATION · 2024-09-03 Matched by certificate designator
ATA 2150

Part: SENSOR — FAULTY (LT A/C PACK) · airframe 119,660 hrs · 12,265 cycles

PACK L EICAS STATUS, OVERHEAT AT LT PACK OUTLET OR LT PACK COMPRESSOR OUTLET OR. LT PACK FLOW CONTROL VALVES (FCVS) ARE CLOSED DUE TO: FCV S FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (C TC) BECAUSE OF FAULT, OVERHEAT, OR PACK FLOW SENSING FAILURE, OR, BOTH FCVS FAILED IN ANY POSITION. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2123491 FLIGHT STATUS: L INTERMITTENCE CODE: M. CABIN TEMPERATURE CONTR OLLER (L CHAN1) POST LT PACK COMPRESSOR DISCHARGE TEMP SENSOR REPLACEMENT, MAT SYSTEM AIR ON TEST CARRIED OUT FOUND TEST PASSED. NIL RELATED FAULTS NOTED AFTER PROLONGED PACKS OPERATION ON GROUND. EXISTING FAULTS NOTED ON MAT. SATIS. BOTH L & RT PACKS OPS SATIS . CMPRSR TEMP SENSOR L EICAS STATUS FAILURE OF BOTH CABIN TEMPERATURE CONTROLLER (CTC) LT PACK COM PRESSOR OUTLET TEMPERATURE SENSORS IN LT PACK. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2123441 FLIGHT STATUS: L INTERMITTENCE CODE: M PH, CABIN TEMPERATURE CONTROLLER (L CHAN2) FIM TASK 21-52-00-810-850 R101 C/OUT, LT PACK COMP RESSOR DISCHARGE TEMP SENSOR REPLACED IAW AMM 21-52-41 PB401 R10 1. MAT SYSTEM AIR ON TEST C/OUT FOUND TEST PASSED.

Source: SDR CALA2024090500573
NO TEST · 2024-04-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 117,751 hrs · 12,064 cycles

M/D R2 DOOR 1EA EMER LT POWER PACK (M33097) FOUND LOW CAPACITY. REPLACED M/D R2 DO OR EMER LT POWER PACK (M33097) AND PERFORMED THE PACK INSTALLATI ON TEST, THE RESULT FOUND NORMAL AS PER AMM 33-51-06-960-803 REV .100.

Source: SDR CALA2024041201059
NO TEST · 2024-04-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 117,751 hrs · 12,064 cycles

M/D L3 DOOR 1EA EMER LT POWER PACK (M33406) FOUND LOW CAPACITY. REPLACED M/D L3 DO OR EMER LT POWER PACK (M33406) AND PERFORMED PACK INSTALLATION T EST, THE RESULT FOUND NORMAL AS PER AMM 33-51-06-960-803 REV,100 .

Source: SDR CALA2024041201060
NO TEST · 2024-04-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 117,751 hrs · 12,064 cycles

M/D OHAR AREA 1EA EMER LT POWER PACK FOUND LOW CAPACITY REF HAECO NON-ROUTINE NO.9482787, ORIGINATED BY EMP V905377, SPEC NO.B77 7-25-3-7250. PERFORMED BY EMP V903218, IDT BY EMP V905377, REPLACED M/D OHAR AREA 1EA EMER LIGHT POWER PACK AND PERFORMED THE PACK INSTALLATI ON TEST, THE RESULT FOUND NORMAL AS PER AMM 33-51-06-960-803 REV .100.

Source: SDR CALA2024041201057
NO TEST · 2024-04-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 117,751 hrs · 12,064 cycles

M/D R3 DOOR 1EA EMER LT POWER PACK (M33404) FOUND LOW CAPACITY. REPLACED M/D R3 DO OR 1EA EMER LIGHT POWER PACK (M33404) AND PERFORMED THE PACK INS TALLATION TEST, THE RESULT FOUND NORMAL IAW AMM 33-51-06-960-803 REV.100.

Source: SDR CALA2024041201058
WARNING INDICATION; OTHER · 2024-02-16 Matched by certificate designator
ATA 3442

Part: SCANNER — FAILED (WX RADAR) · airframe 117,370 hrs · 12,022 cycles

WXR SYS EICAS STATUS WXR DISPLAY IS NOT PRESENT WHEN WXR SELECTED ON EFIS CONTROL PAN EL. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 3189124. DISPLAYS-1 IN RIGHT AIM S CMC MSG# 318912. DISPLAYS-2 IN RIGHT AIM S CMC MSG# 3189113. DISPLAYS-1 IN LEFT AIMS PER FLIGHT CREW: HAD A WXR FAIL AMBER ON CAPT AND FO'S ND AND WASN'T PAINTING ON EITHER. REMOVED AND REPLACED WXR PEDESTLE AMM 34-43-03-400-801 OPS INITIALLY GOOD BUT RIGHT TRANSCEIVER FAILED DURING TEST. SWAPPED RIGHT TO LEFT AND FAILURE FOLLOWED TO LEFT SIDE. FAILED R/T IS STILL IN LEFT POSITION.

Source: SDR CALA2024021900466
OTHER · 2024-01-25 Matched by certificate designator
ATA 5100

Part: PAINT — DAMAGED (RT STATIC PORT) · airframe 117,106 hrs · 11,994 cycles

RT CENTRE STATIC PORT HAS PAINT DAMAGE NEAR RVSM AREA 1120-01518. INSP DAILY AND RECTIFY WITHIN 5 DAYS. PHOTO TO FOLLOW STATIC PORT CIRCULAR STENCIL TRIMMED AND STILL LEGIBLE, P/N 777-53-11S. MISSING AREA FILLED IN WITH SHARPIE PER ECRA, OK TO PLACE ON DIP PER ECRA 1120-01518 REV A, PART 1 INTERIM TOMC-APPROVAL FROM SC1ELBYC COMMENT REPAIR COMPLETED, ACCOMPLISH REPETITIVE INSPECTION PER PART 2 DAILY AND ACCOMPLISH A PERMANENT REPAIR PER PART 3 WITHIN 5 CALENDAR DAYS. RECORDS UPDATE ALLOWABLE LIMITS. REF SRM 51-10-03-0G-0. TOMCQC REV PERFORMED VERIFIED PAINT CURED. VERIFIED PAINT CURED REF. ECRA 1120-01518 REF. A, SRM 51-10-03-0G-0. IN REF TO ECRA 1120-01518, APPLIED TOUCH UP PAINT AROUND RT. INSPECTED RT CTR STATIC PORT EXTRA CRITICAL AREA, FOUND BLACK CONTINUED TO APPLIED HEAT, PAINT DRY VERIFIED PAINT CURED , AREA WITHIN RVSM LIMITS. REF. ECRA CENTER STATIC PORT, MORE TIME NEEDED FOR PAINT CURE COLOR CIRCLE PAINT SMOOTHNESS IS MORE THAN MAX. OF + 0.003" 1120-01518 REF. A, SRM 51-10-03-0G-0. REMOVED ALL BLACK PAINT FROM STATIC PORT AREA, APPLIED PRIMER AND NEW BLACK PAINT. REF 51-103-0G-0 & 51-10-00-200-804 TOMC APPROVED : QC REVIEWED. RIR: DAILY ("D" METER) NO M&E REQUIRED T/A: 5 DAYS.

Source: SDR CALA2024020200283

2023

OTHER · 2023-06-05 Matched by certificate designator
ATA 7200

Part: PANEL — UNKNOWN (ENG 1 INLET) · airframe 114,016 hrs · 11,634 cycles

PDA 1 REF LP 4785250, FLAGGING PDA. NO 1 ENG FAN STATOR CASE OUTER ACOUSTIC LINER BETWEEN 4 & 6 O''CLOCK FACING AFT DEBONDED. TOTAL SURFACE OF DEBONDING IS 47" X 12" = 564 " SQ. FOUND ON WALKAROUND.

Source: SDR CALA2023060701765
OTHER · 2023-01-27 Matched by certificate designator
ATA 2421

Part: IDG — INOPERATIVE (LT GENERATOR) · airframe 112,255 hrs · 11,431 cycles

ABORTED T/O @ 80 KNOTS DUE TO LEFT GEN DRIVE. WHILE ATEMPTING TO APPLY MEL2411B THE LEFT IDG OIL LEVEL READS SERVICE. RAMP IS CURRENTLY CLOSED FOR WEATHER. REQUEST MEL 2411B DUE TO ABOVE MX MESSAGE LOW FREQ. PLACED NR 1 ENG IDG ON MEL 2411B. PERFORMED DDP. ENGINE DRIVEN GENERATOR LT, MEL 2411B SERVICED NR 1 ENG IDG TO FULL, READS NORMAL.IAW AMM 12-13-03-600-802. EF AMM 24-11-01-000-801-001. ACP IDT INSP OF #1 ENG IDG FEEDER CABLES INSTALLATION & TORQUED QUAD RING IAW AMM 24-11-01-400-801-001. PERFORMED ELOTO ON LE AND LT THRUST REVERSER, REPLACED LT ENGINE IDG IAW MM 24-11-01-400-801-001. REMOVED NR 1 ENGINE IDG. NEW TORQUED QUAD RING AND IDG FEEDER CABLES . REPLACED LT ENGINE IDG IAW MM 24-11-01-400-801-001-001 OPS CHKS GOOD, ALL INDICATIONS NORMAL.

Source: SDR CALA2023012700237

2022

OTHER · 2022-11-28 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (BS 2370 BLKHEAD) · airframe 111,549 hrs · 11,350 cycles

SUPPORT TASK - EA-530-0113 REV B OP.17 AD 2022-06-07 LH BS 2370 PIVOT B/HEAD FWD OUTER CHORD. LH BS 2370 PIVOT BULKHEAD FWD OUTER CHORD REPLACED AND INSTALLED AS PER EA5380-01113 REV B OP025.

Source: SDR CALA2022113003249
OTHER · 2022-11-28 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (BULKHEAD) · airframe 111,549 hrs · 11,350 cycles

SUPPORT TASK - EA 5380-01113 REV B OP.18 AD 2022-06-07 RH BS 2370 PIVOT B/HEAD FWD OUTER CHORD FOUND CRACKED, BS 2370 PIVOT BULKHEAD FWD OUTER CHORD REPLACED AND INSTALLED AS PER EA5380-01113 REV B OP026.

Source: SDR CALA2022113003248
NO TEST · 2022-11-20 Matched by certificate designator
ATA 3300

Part: BATTERY — INOPERATIVE (L2 DOOR) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 - R2 DOOR GALLEY CEILING AREA EMER LIGHT FOUND DIM TRANSFER REF HXWO 1232121 AND ORIGINATED BY EMP V934740 L2 DOOR EMER LIGHT POWER PACK (M33096) (BATTERY AND CHARGER) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V907892 INSPECTED BY V926996 IDT INSPECTED BY HX136003 ADD EMP:V897810 CORRECTION MADE BY V926996 DEFECT LOCATION SHOULD BE L2 DOOR ADD EMP:V926996

Source: SDR CALA2022112103184
NO TEST · 2022-11-20 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (R4 DOOR) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 - SEAT 46-52KL CEILING AREA EMER LIGHT DOUND DIM TRANSFER REF HXWO 1232120 AND ORIGINATED BY EMP V934740 R4 DOOR EMER LIGHT POWER PACK M33409 (BATTERY AND CHARGER) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-06 WORK ACCOMPLISHED BY MECHANIC V907892 INSPECTED BY V926996 IDT INSPECTED BY HX136003 ADD EMP:V897810

Source: SDR CALA2022112003172
NO TEST · 2022-11-20 Matched by certificate designator
ATA 3300

Part: BATTERY — INOPERATIVE (L1 DOOR) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 SEAT 1-9A CEILING EMERG AREA LT FOUND DIM TRANSFER REF HXWO 1233584 AND ORIGINATED BY EMP V934740 L1 DOOR EMER LIGHT POWER PACK M33424 (BATTERY AND CHARGER) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V907892 INSPECTED BY V926996 IDT INSPECTED BY HX136003 ADD EMP:V897810

Source: SDR CALA2022112103187
NO TEST · 2022-11-20 Matched by certificate designator
ATA 3300

Part: BATTERY — INOPERATIVE (R3 DOOR) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 - ZONE C EY SEAT FLOOR PROX LIGHT FOUND DIM TRANSFER REF HXWO 1232130 AND ORIGINATED BY EMP V934740 R3 DOOR EMER LIGHT POWER PACK BATTERY AND CHARGER REPLACED (M33401) AND OPERATION TEST NORMAL REF AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V907889 INSPECTED BY V926996 IDT INSPECTED BY HX136003 ADD EMP:V897810

Source: SDR CALA2022112103186
NO TEST · 2022-11-20 Matched by certificate designator
ATA 3300

Part: BATTERY — INOPERATIVE (L1 DOOR) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 - SEAT 1-9L CEILING AREA EMER LIGHT FOUND DIM TRANSFER REF HXWO 1232129 AND ORIGINATED BY EMP V934740 L1 DOOR EMER LIGHT POWER PACK (BATTERY AND CHARGER) (M33093) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V907892 INSPECTED BY V926996 IDT INSPECTED BY HX136003 ADD EMP:V897810

Source: SDR CALA2022112103185
NO TEST · 2022-11-20 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (R2 DOOR) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 - ZONE B BC SEAT FLOOR PROX LIGHT FOUND DIM TRANSFER REF HXWO 1232115 AND ORIGINATED BY EMP V934740 R2 DOOR EMER LIGHT BATTERY (M33098) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-06 WORK ACCOMPLISHED BY MECHANIC V907892 AND INSPECTED BY V926996 IDT INSPECTED BY HX136003 ADD EMP:V897810

Source: SDR CALA2022112103183
NO TEST · 2022-11-11 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 111,549 hrs · 11,350 cycles

B777-33-3-7019 - ZONE A BC SEAT FLOOR PROX LIGHT FOUND DIM TRANSFER REF HXWO 1232113 AND ORIGINATED BY EMP V934740 ZONE A R1 DOOR (M33094) EMERGENCY BATTERY AND CHARGER REPLACED AND INSTALLATION TEST NORMAL REF AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V907889 INSPECTED BY V896995

Source: SDR CALA2022111403125
OTHER · 2022-07-18 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (DOOR 3L) · airframe 110,244 hrs · 11,206 cycles

FOUND EMERGENCY BATTERY PACK M33405 ABOVE DOOR 3 LEFT NEEDS NEW BATTERY PACK, M&E 99-3351-3-0015 NIS IN IAH BATTERY PACK IS FOR EMERGENCY LIGHTS INSTALLED NEW BATTERY PACK. OPS CHECK OK REF AMM 33-50 VERIFIED BATTERY INSTALLED REF AMM 33-51-06. OPS CHECK GOOD.

Source: SDR CALA2022071801804

2021

SMOKE/FUMES/ODORS/SPARKS · 2021-08-26 Matched by certificate designator
ATA 2400

Part: RELAY — ARCED · airframe 106,997 hrs · 10,633 cycles

GATE RETURN SMOKE IN THE CABIN. FOUND ELECTRICAL ARCING ON THE P300 PANEL UPON ASESSMENT OF DAMAGE TO P300 PANEL, REMOVED AND FOUND RELAY K24002 GROUND SERVICE SELECT RELAY SEVERELY DAMAGED, SUSPECT INTERNAL FAILURE. NO FOD NOTED IN AREA. REFERENCE SSM 24-22-41, WDM 24-21-31, 24-51-41. AC AND (1 EA.) P-49 PANEL A-5 VOICE RCDR RELAY. REF. AMM TASK # 23-71-01. [ACFT. # 0009]. VOX RCDR; (2 EA.) P-210 PANEL L-12 FLT. RCDR DC & E-23 FLT. RCDR F.O.M. (REF. L.P. # 6861022). LOCATION: (1 EA.) P-11 PANEL E-13 DE-ACTIVATED (PULLED) 4 EA. FLT. RECORDER CIRCUIT BREAKERS. FOUND WIRE W4830-0301-1/0 BURNED AT P-300 PANEL. FOUND WIRE W4830-0401-1/0 BURNED AT P-300 PANEL. FOUND WIRE W4830-0302-1/0 BURNED AT P-300 PANEL. FOUND WIRE W4830-0402-1/0 BURNED AT P-300 PANEL. FOUND WIRE W4830-0303-1/0 BURNED AT P-300 PANEL. FOUND WIRE W4830-0403-1/0 BURNED AT P-300 PANEL. ADD EMP:U131143 24-41-31. FOUND WIRE W4030-0001-2/0 BURNED AT P-300 PANEL. REFERENCE WDM FOUND WIRE W4030-0002-2/0 BURNED AT P-300 PANEL. REFERENCE WDM 24-41-31. 24-41-31. FOUND WIRE W4030-0003-2/0 BURNED AT P-300 PANEL. REFERENCE WDM FOUND WIRE W4030-0004-04 BURNED AT P-300 PANEL. REFERENCE WDM 24-41-31. 24-22-41. FOUND WIRE W4228-0004-02 BURNED AT P-300 PANEL. REFERENCE WDM FOUND WIRE W4228-0005-02 BURNED AT P-300 PANEL. REFERENCE WDM 2

Source: SDR CALA2021082701439
NO TEST · 2021-05-16 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - EMER LT PWR PACK M33407 OPERATION TEST FAIL. REF NR LP 9131393. PWR PACK M33047 BATTERY REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06. IDT INSPECTED BY HX102640. ADD EMP:V926992

Source: SDR CALA2021051700668
NO TEST · 2021-05-16 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - EMER LT PWR PACK M33408 OPERATION TEST FAIL. REF NR LP 9131395. PWR PACK M33048 BATTERY REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06. ADD EMP:V897810 IDT INSPECTED BY HX102640. ADD EMP:V896992

Source: SDR CALA2021051700669
OTHER · 2021-05-14 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (LH STATIC PORT) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - LH L SYS STATIC PORT FOUND SURFACE ROUGH. REF NR LP 9131404. LH L SYS STATIC PORT ROUGH SURFACE SMOOTHED OUT AS PER SRM 51-10-01-2R-1 REPAIR, AND SMOOTHED OUT AREA MEASURED REMAINING THICKNESS 0.129" ORIGINAL THICKNESS 0.130" WITHIN LIMIT AS PER SRM 51-10-01-2R-1 REPAIR 1 WITH CONFIRMED NO CRACK FOUND AND SKIN WAVINESS CHECK CARRIED OUT AND AVERAGE PORT WAVINESS IS ADD EMP:V906449 -0.0005 IN WITHIN LIMIT AS PER AMM 51-10-00-200-801. RII INSPECTED BY HX247305.

Source: SDR CALA2021051400653
OTHER · 2021-05-14 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (RH STATIC PORT) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - RH R SYS STATIC PORT FOUND SURFACE ROUGH. REF NR LP 9131401. RH R SYS STATIC PORT ROUGH SURFACE SMOOTHED OUT AS PER SRM 51-10-01-2R-1 REPAIR 1 AND MEASURED REMAINING THICKNESS IS 0.129" ORIGINAL THICKNESS 0.130" WITHIN LIMIT AS PER SRM 51-10-01-2R-1 REPAIR 1 WITH CONFIRMED NO CRACK FOUND SKIN WAVINESS CHECK CARRIED OUT AND AVERAGE PORT WAVINESS IS 0.0015 ADD EMP:V906449 IN. WITHIN LIMIT AS PER AMM 51-10-00-200-801. RII INSPECTED BY HX247305.

Source: SDR CALA2021051400654
OTHER · 2021-05-14 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (RH CTR STATIC P) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - RH CTR SYS STATIC PORT FOUND SURFACE ROUGH. REF NR LP 9131403. RH CTR SYS STATIC PORT ROUGH SURFACE SMOOTHED OUT AS PER SRM 51-10-01-2R-1 REPAIR 1 AND MEASURED REMAINING THICKNESS 0.128" ORIGINAL 0.130" WITHIN LIMIT AS PER SRM 51-10-01-2R-1 REPAIR 1 WITH CONFIRMED NO CRACK FOUND, SKIN WAVINESS CHECK CARRIED OUT AND AVERAGE PORT WAVINESS IS -0.0005 IN WITHIN LIMIT AS PER AMM ADD EMP:V906449 51-10-00-200-801. RII INSPECTED BY HX247305

Source: SDR CALA2021051400656
OTHER · 2021-05-14 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - EMER LT PWR PACK M33099 CANNOT BE CHARGED UP. REF NR LP 9131392. PWR PACK M33099 CHARGER REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06. IDT INSPECTED BY HX102640. ADD EMP:V926992

Source: SDR CALA2021051400659
OTHER · 2021-05-14 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (RH STATIC PORT) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - RH L SYS STATIC PORT FOUND SURFACE ROUGH. REF NR LP 9131402. RH L SYS STATIC PORT ROUGH SURFACE SMOOTHED OUT AS PER SRM 51-10-01-2R-1 REPAIR 1 AND MEASURED REMAINING THICKNESS 0.129" ORIGINAL THICKESS 0.130" WITHIN LIMIT AS PER SRM 51-10-01-2R-1 REPAIR 1 WITH CONFIRMED NO CRACK FOUND. SKIN WAVINESS CHECK CARRIED OUT AND AVERAGE PORT WAVINESS IS -0.0005 IN WITHIN ADD EMP:V906449 LIMIT AS PER AMM 51-00-00-200-801. RII INSPECTED BY HX247305.

Source: SDR CALA2021051400652
OTHER · 2021-05-14 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (LH STATIC PORT) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - LH R SYS STATIC PORT FOUND SURFACE ROUGH. REF NR LP 9131400. LH R SYS STATIC PORT ROUGH SURFACE SMOOTHED OUT AS PER SRM 51-10-01-2R-1 REPAIR 1 AND MEASURED REMAINING THICKNESS IS 0.129" ORIGINAL THICKNESS 0.130" WITHIN LIMIT AS PER SRM 51-10-01-2R-1 REPAIR 1 WITH CONFIRMED NO CRACK FOUND SKIN WAVINESS CHECK CARRIED OUT AND AVERAGE PORT WAVINESS IS -0.0005 ADD EMP:V906449 IN. WITHIN LIMIT AS PER AMM 51-10-00-200-801. RII INSPECTED BY HX247305.

Source: SDR CALA2021051400655
OTHER · 2021-05-14 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 106,230 hrs · 10,477 cycles

SUPPORT TASK - EMER LT PWR PACK M33099 OPERATION TEST FAIL. REF NR LP 9131397. PWR PACK M33099 BATTERY REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06. ADD EMP:V897810 IDT INSPECTED BY HX102640.

Source: SDR CALA2021051400660

2020

OTHER · 2020-09-24 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 105,129 hrs · 10,329 cycles

EMERGENCY BATTERY PACK PN AD-717-01-100 FOUND INOPERABLE AT L3 DOOR. REPLACED EMERGENCY BATTERY PACK, IAW AMM 33-51-06-960-803 AT L3 DOOR. OPS CHECK GOOD. WORK ACCOMPLISHED ON AERSALE NR 489613 BY V 931306.

Source: SDR CALA2020092601145
OTHER · 2020-09-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 105,129 hrs · 10,329 cycles

EMERGENCY BATTERY PACK PN AD-D717-01-100 FOUND INOPERABLE AT R3. REPLACED EMERGENCY BATTERY PACK, IAW AMM 33-51-06-960-803 AT R3 DOOR. OPS CHECK GOOD.

Source: SDR CALA2020092601143
OTHER · 2020-09-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 105,129 hrs · 10,329 cycles

EMERGENCY BATTERY PACK PN AD-D717-01-100 FOUND INOPERABLE AT R3 DOOR. REPLACED EMERGENCY BATTERY PACK, IAW AMM 33-51-06-960-803 AT R3 DOOR. OPS CHECK GOOD.

Source: SDR CALA2020092601144
OTHER · 2020-09-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 105,129 hrs · 10,329 cycles

EMERGENCY BATTERY PACK PN AD D717-01-100 AT L3 DOOR INOPERABLE. REPLACED EMERGENCY BATTERY PACK, IAW AMM 33-51-06-960-803 AT L3 DOOR. OPS CHECK GOOD. WORK ACCOMPLISHED ON AERSALE NR 489613 BY V 931306.

Source: SDR CALA2020092601146
NO TEST · 2020-04-06 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (CABIN) · airframe 105,113 hrs · 10,327 cycles

B777-33-3-7007 DR4 EMER LIGHT POWER SUPPLY M33408 BATTERY PACK C APCITY LOW REF NR LP 9130406 DR4 EMER LIGHT POWER SUPPLY M33408 BATTERY PACK AND CHARGER REPL ACED AND TESTED NORMAL AS PER AMM 33-51-06

Source: SDR CALA2020041000804
NO TEST · 2020-04-06 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 105,113 hrs · 10,327 cycles

B777-33-3-7007 DR R1 EMER LIGHT POWER SUPPLY M33094 BATTERY PACK CAPACITY LOW REF NR LP 9130408 DR R1 EMER LIGHT POWER SUPPLY M33094 BATTERY PACK REPLACED AND T ESTED NORMAL AS PER AMM 33-51-06

Source: SDR CALA2020041000805
NO TEST · 2020-04-06 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 105,113 hrs · 10,327 cycles

B777-33-3-7007 DR R3 EMER LIGHT POWER SUPPLY M33401 BATTERY PACK CAPACITY LOW REF NR LP 9130410 DR R3 EMER LIGHT POWER SUPPLY M33401 BATTERY PACK PLACED AND TES TED NORMAL AS PER AMM 33-51-06

Source: SDR CALA2020041000807
NO TEST · 2020-04-06 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 105,113 hrs · 10,327 cycles

B777-33-3-7007 DR R3 EMER LIGHT POWER SUPPLY M33404 BATTERY PACK CAPACITY LOW REF NR LP 9130409 DR R3 EMER LIGHT POWER SUPPLY M33404 BATTERY PACK REPLACED AND T ESTED NORMAL AS PER AMM 33-51-06

Source: SDR CALA2020041000806

2019

WARNING INDICATION · 2019-12-22 Matched by certificate designator
ATA 2150

Part: CONTROL VALVE — MALFUNCTIONED (AC BAY) · airframe 104,319 hrs · 10,246 cycles

PACK FCV LWR L STATUS MESSAGE LT PACK OFF LT ON T/S PER FIM 21-51-00-810-831, 28VDC PRESENT AT DV21513A. PER FIM NEEDS NEW FCV. FAULT. CONTINUED WITH FIM AND VERIFED FCV POSITION SENSOR WIRING. CHANGED LOWER FLOW CONTROL AND SHUT OFF VALVE REF AMM 21-51-02. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1225725 SN OFF 9277 VALVE, AIR, PAC OFF 25-2151-9-0002 9277 ON 25-2151-9-0002 0918 FOUND MX MSG 21-24303. TS PER FIM AND FOUND IT WAS INTERMITENT

Source: SDR CALA2020010600012

2018

SMOKE/FUMES/ODORS/SPARKS · 2018-11-25 Matched by certificate designator
ATA 2330

Part: NOT REPORTED — SPARKS (CABIN) · airframe 99,309 hrs · 9,730 cycles

PAX SAW SPARKS FROM UNDER SEAT 17K SPARK ORIGINATED FROM 16K. SPM DISCONNECTED AT 16K (PRECAUTIONARY) NO DAMAGE OR WIRING FAULTS FOUND. IFE INOP AT SEATS 16-17 JKL.

Source: SDR CALA2018112502433
NO TEST · 2018-08-22 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 97,936 hrs · 9,607 cycles

R2 DOOR AREA CEILING EMERGENCY LIGHT POWER SUPPLY M33097 CHARGER WAS INOPERATIVE. THE CHARGER WAS REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.

Source: SDR CALA2018082701844
NO TEST · 2018-08-22 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 97,936 hrs · 9,607 cycles

L3 DOOR AREA CEILING EMERGENCY LIGHT POWER SUPPLY M33406 CHARGER WAS INOPERATIVE. THE CHARGER WAS REPLACED, OPS CHECKED NORMAL IAW AMM 33-51-06.

Source: SDR CALA2018082701843
NO TEST · 2018-08-21 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHT) · airframe 97,936 hrs · 9,607 cycles

R2 DOOR AREA CEILING EMERGENCY LIGHT POWER SUPPLY M33098 BATTERY CAPACITY WAS LOW. THE BATTERY PACK WAS REPLACED, OPS CHECKED NORMAL IAW AMM 33-51-06.

Source: SDR CALA2018082701842
NO TEST · 2018-08-21 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHT) · airframe 97,936 hrs · 9,607 cycles

R2 DOOR AREA CEILING EMERGENCY LIGHT POWER SUPPLY M33097 BATTERY CAPACITY WAS LOW. THE BATTERY PACK WAS REPLACED, OPS CHECKED NORMAL IAW AMM 33-51-06.

Source: SDR CALA2018082701840
NO TEST · 2018-08-20 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHT) · airframe 97,936 hrs · 9,607 cycles

L3 DOOR AREA CEILING EMERGENCY LIGHT POWER SUPPLY M33406 BATTERY CAPACITY WAS LOW. THE POWER SUPPLY BATTERY PACK WAS REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.

Source: SDR CALA2018082761835
OTHER · 2018-08-20 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 97,936 hrs · 9,607 cycles

CEILING EMERGENCY LIGHT POWER SUPPLY M33098 CHARGER WAS INOPERATIVE. THE CHARGER WAS REPLACED, OPS CHECKED NORMAL IAW AMM 33-51-06.

Source: SDR CALA2018082601836
OTHER · 2018-05-25 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (EMERGENCY LIGHT) · airframe 96,946 hrs · 9,506 cycles

R4 DOOR EXIT LIGHT LENS WAS MISSING. SECURED THE LENS, ALL OK.

Source: SDR CALA2018060531360

2017

NO TEST · 2017-04-07 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 90,846 hrs · 8,947 cycles

IN FA CREW REST AREA FLASH LIGHT UNDER BUNK 3 INOP. REPLACED F/A EMERGENCY FLASHLIGHT BATTERY, OPS CHECK GOOD.

Source: SDR CALA2017040700915
NO TEST · 2017-02-06 Matched by certificate designator
ATA 5210

Part: BATTERY — DISCHARGED (R4 DOOR) · airframe 90,022 hrs · 8,876 cycles

DOOR 4R EPAS FAILED OPERATIONAL TEST NO GREEN OR AMBER LIGHTS. REF W/C 25-5210-1-9801 PARA D STEP G7. REMOVED AND REPLACED EMERGENCY POWER ASSIST SYSTEM BATTERY REF AMM 52-11-25 OPS CHECK GOOD INSPECTED 4R DOOR OPS CHECK OF EMERGENCY POWER ASSIST BATTERY, OPS CHECK GOOD..

Source: SDR CALA2017020600286

2015

OTHER · 2015-08-13 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 82,353 hrs · 8,205 cycles

SUPPORT TASK, CABIN ZONE B LT STATION 845 - 1097, FOUR EACH EMER AREA LIGHT FOUND DIM. CABIN ZONE B LT DOOR NR 2 OVERHEAD, ONE EACH BATTERY PACK M33099 REPLACED IAW AMM 33-51-06 & EMER LIGHT TEST FOUND NORMAL IAW AMM 33-51-00.

Source: SDR CALA2015081400667
OTHER · 2015-08-13 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 82,353 hrs · 8,205 cycles

SUPPORT TASK, CABIN ZONE D RT STATION 1581 - 1665, TWO EACH EMER AREA LIGHTS FOUND DIM. CABIN ZONE D RT DOOR NR 3 OVERHEAD ONE EACH BATTERY PACK M33401 REPLACED IAW AMM33-51-06 & EMER LIGHT TEST FOUND NORMAL IAW AMM 33-51-00.

Source: SDR CALA2015081400669
NO TEST · 2015-08-13 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 82,353 hrs · 8,205 cycles

SUPPORT TASK, CABIN ZONE B LT STATION 1181 - 1433, FOUR EACH EMER AREA LIGHTS FOUND DIM. CABIN ZONE D LT DOOR NR 3 OVERHEAD, ONE EACH POWER SUPPLY M33400 & ONE EACH POWER PACK 33400 REPLACED IAW AMM 33-51-06. EMER LIGHT TEST FOUND NORMAL IAW AMM 33-51-00.

Source: SDR CALA2015081400670
NO TEST · 2015-08-13 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 82,353 hrs · 8,205 cycles

SUPPORT TASK, CABIN ZONE A RT STATION 423 - 676, FOUR EACH EMER AREA LIGHTS FOUND DIM. CABIN RT DOOR NR 1 OVERHEAD, ONE EACH POWER SUPPLY M33093 & ONE EACH BATTERY PACK M33093 REPLACED IAW AMM 33-51-06. EMER LT TEST FOUND NORMAL IAW AMM 33-51-00.

Source: SDR CALA2015081400671
OTHER · 2015-08-13 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 82,353 hrs · 8,205 cycles

LEFT DOOR 1 EXTERIOR EMER LIGHT FOUND DIM. CABIN LT DOOR NR 1 OVERHEAD, ONE EACH POWER SUPPLY M33424 & ONE EACH BATTERY PACK M33424 REPLACED IAW AMM 33-51-06 & EMER LIGHT TEST FOUND NORMAL IAW AMM 33-51-00.

Source: SDR CALA2015081400668
SMOKE/FUMES/ODORS/SPARKS · 2015-08-13 Matched by certificate designator
ATA 2421

Part: GENERATOR — ARCED (APU) · airframe 82,353 hrs · 8,205 cycles

APU GENERATOR T2 TERMINAL FOUND ARCING. APU GENERATOR ASSEMBLY REPLACED IAW AMM 24-21-01. APU GENERATOR FEEDER HARNESS REPLACED IAW AMM 24-21-02 & 24-21-01. APU GENERATOR INSTALLATION TEST IAW AMM 24-21-01, CARRIED OUT NORMAL. ROTABLE PARTS CHANGE WAS INDICATED TT 1706206, SN OFF 00329 GENERATOR, APU OFF 25-2421-9-0001 0329 ON 25-2421-9-0001 0376.

Source: SDR CALA2015081400672
PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2015-01-08 Matched by certificate designator
ATA 7230

Part: COMPRESSOR — STALLED (NR 2 ENGINE) · airframe 79,808 hrs · 7,987 cycles

RIGHT ENG COMP STALL & DISPLAYED ENG FAIL AT 80 KTS ON FULL POWER TO DUE STRONG LT CROSSWINDS & WIND SHEAR. COMPLIED WITH ENG STALL INSPECTION IAW MM 71-00-00-200-809. ALL CHECKED OK. COMPLIED WITH NR 2 ENG BORESCOPE IAW 71-00-00-200. ALL DAMAGE FOUND, ALL WITHIN LIMITS IAW AMM 72-00-00-290-814-G00 & 72-00-00-290-812-G00.

Source: SDR CALA2015010900028

2011

OTHER · 2011-10-24 Matched by certificate designator
ATA 7230

Part: PLUG — MISSING (NR 1 ENGINE) · airframe 63,166 hrs · 6,507 cycles

WHILE PERFORMING T/S ON NR 1 ENG, FOUND DAMAGE ON LEFT T/R FIRE BLANKET ALSO FOUND HIGH PRESS COMPRESSOR BOROSCOPE PLUG MISSING ON LEFT SIDE (8TH STAGE VANE H.P.C ROTOR). INSTALLED REPLACEMENT BOROSCOPE PLUG (J) PER AMM 72-00-00-290 812-G00, (NOTE) FIRE BLANKET DAMAGE TRANSFER TO L/P 4523119,20 AND 21.

Source: SDR CALA2011102400684
SMOKE/FUMES/ODORS/SPARKS · 2011-10-03 Matched by certificate designator
ATA 2400

Part: OUTLET — DEFECTIVE (CABIN) · airframe 62,890 hrs · 6,480 cycles

NOTED ACRID BURNING ODOR IN AREA OF SEATS 42 TO 43 PERFORMED TASK 05-51-58-910-801C5 FOUND IN SEAT POWER OUTLET AT 4 40K INTERMITTING WHEN A POWER SOURCE WAS PLUGGED IN ALSO SMELL R&R IPO OPS CHECKS GOOD NO SMELLS NOTED.

Source: SDR CALA2011100400640

2010

FALSE WARNING · 2010-05-30 Matched by certificate designator
ATA 3510

Part: INDICATION SYS — MALFUNCTIONED (O2 SYSTEM) · airframe 55,804 hrs · 5,829 cycles

CLIMBING THRU 16.000 RECEIVED A CLEAR O2 LOW EICAS MSG. PRESSURE READ 50 PSI BUT 1400 PSI DURING PRE FLIGHT. PLACED INDICATION ON DEFERRAL INOP CONFIRMED BOTTLE NR 1 AT 1700 PSI, BOTTLE NR 2 AT 1700 PSI, OK TO CONTINUE.

Source: SDR CALA2010060100237

2007

OTHER · 2007-05-26 Matched by certificate designator
ATA 5313

Part: LONGERON — CRACKED (BS 2272 L26R) · airframe 39,439 hrs · 4,360 cycles

INSPECTION FOUND A .5 INCH CRACK IN AFT LOWER LONGERON STRAP AT RIGHT LOWER SEAL FAIRING AREA, STA 2272, S26R. REPAIRED IAW ECRA 5310-04631.

Source: SDR CALA0700268
OTHER · 2007-05-24 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (BS 2272) · airframe 39,439 hrs · 4,360 cycles

INSPECTION FOUND A .5 INCH CRACK IN RIGHT LOWER SEAL FAIRING SKIN AT BS 2272, S26R. THE SKIN WAS REPAIRED IAW SRM 53-80-70, REPAIR 1, FIGURE 204.

Source: SDR CALA0700264
OTHER · 2007-05-24 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 2344-2370) · airframe 39,439 hrs · 4,360 cycles

INSPECTION FOUND SKIN CORRODED AT BS 2344-2370, S38R-S43R (TAIL COMPARTMENT AREA). THE SKIN WAS REPAIRED IAW SRM 53-00-01, REPAIR 7, FIGURE 202.

Source: SDR CALA0700263

2005

SMOKE/FUMES/ODORS/SPARKS · 2005-12-31 Matched by certificate designator
ATA 2330

Part: CONTROL UNIT — SHORTED (L-3 DOOR) · airframe 32,126 hrs · 3,681 cycles

PASSENGERS AND FLIGHT ATTENDANT'S REPORTED A WHIFF OF ELECTRICAL ODOR IN THE CABIN AT A ZONE, B ZONE, AND IN AFT CABIN NEAR ROW 25 WHILE EN ROUTE TO IAH. THE ODOR RETURNED LATER WITH A VISIBLE HAZE. THE APPROPRIATE CHECKLIST WAS RUN AND THE ODOR AND HAZE CEASED. THE AIRCRAFT LANDED AT IAH WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND THE OEU (OVERHEAD ELECTRONICS UNIT) AT L-3 DOOR SHORTED. THE OEU WAS REMOVED AND REPLACED, OPERATIONAL CHECKS WERE GOOD.

Source: SDR CALA0500464

2003

OTHER · 2003-07-15 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 19,846 hrs · 2,313 cycles

INSPECTION FOUND SEAT TRACK CROWN CORRODED AT BS 1513, LBL 85. THE SEAT TRACK WAS REPLACED IAW SRM 51-10-02 AND 51-40-02.

Source: SDR CALA0300390
OTHER · 2003-07-15 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 19,846 hrs · 2,313 cycles

INSPECTION FOUND SEAT TRACK CROWN CORRODED AT BS 1497-1530, RBL 74. THE SEAT TRACK WAS REPAIRED IAW SRM 53-00-52, REPAIR 3, FIGURE 202.

Source: SDR CALA0300391
OTHER · 2003-07-15 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 19,846 hrs · 2,313 cycles

INSPECTION FOUND SEAT TRACK CROWN CORRODED AT BS 1513-1530, RBL 108. THE SEAT TRACK WAS REPAIRED IAW SRM 53-00-52, REPAIR 4, FIGURE 202.

Source: SDR CALA0300392
OTHER · 2003-07-11 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (FUSELAGE) · airframe 19,846 hrs · 2,313 cycles

INSPECTION FOUND FUSELAGE SKIN DENTED 3 INCHES FORWARD OF STA 676, FORWARD OF L-2 DOOR BETWEEN STRINGERS 27L AND 28L. REPAIRED IAW SRM 53-00-01, REPAIR 7.

Source: SDR CALA0300383

1999

WARNING INDICATION · 1999-10-19 Matched by certificate designator
ATA 3231

Part: SELECT VLV — INOP (MLG DOOR)

A POP WAS HEARD WHILE ON APPROACH TO EWR AT 4,000 FEET. THE GEAR WAS LOWERED, BUT THE GEAR DOOR REMAINED OPEN. THE AIRCRAFT LANDED AT EWR WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE MLG SELECTOR /BYPASS VALVE IAW MM 32-31-03, PAGE 401. LEAK AND OPERATIONAL CHECKS WERE GOOD.

Source: SDR CALA9901403