N781UA
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
189 reports on file, 1996-10-08 – 2026-10-27.
Part: UNKNOWN — ODOR (MID CABIN) · airframe 109,095 hrs · 19,817 cycles
FA REPORTS AN ODOR OF OIL OR HYD FLUID INTERMITTNTLY DURING FLIGHT IN MID GALLEY. SPOKE TO INBOUND CAPT AND PURSER. PURSER SAID SHE COULD NOT IDENTIFY EXACT ODOR. ODOR WAS OIL LIKE, BUT ODOR WAS MOMENTARY NOT THROUGHOUT THE FLIGHT AND ONLY IN MID GALLEY AREA. PULLED OUT ALL FOOD AND BEVERAGE CARTS AND RAN AC PACKS, RAN HYDRAULICS, RAN MID GALLEY CHILLERS & ALL OVENS AND WARMERS. COULD NOT DUPLICATE ANY UNUSUAL ODORS AT THIS TIME. CHECKED 90 DAY HISTORY BUT FOUND NO PREVIOUS COMPLAINTS OR WRITE UPS. OK TO CONTINUE.
Part: ENGINE — MALFUNCTIONED (NR 2) · airframe 109,070 hrs · 19,811 cycles
RIGHT ENGINE FAILED, EGT EXCEEDED IAW PILOT REPORT. AT APPROX 6,000 FT ABOVE AIRFIELD, NR 2 ENGINE EXPERIENCED HIGH EGT SPIKE, REPORTEDLY REACHING 845 DEGREE CELIUS, FOLLOWED BY AUTO SHUTDOWN. FLIGHT CREW ACCOMPLISHED APPLICABLE CHECKLIST. NO FURTHER ABNORMALITIES REPORTED ON INITIAL EVALUATION. FOUND RT ENG OIL QTY LOW AT 13 QTS, NO SIGNS OF SIGNIFICANT OIL LEAK WITH COWLS CLOSED, AND NO EVIDENCE OF MATERIAL IN THE TAIL PIPE OR SIGNS OF OBVIOUS DAMAGE. NOTED FOUR EXCEEDANCE PAGES FOR ENG FAIL, RT ENG THRUST, RT ENG EGT RED, & RT ENG EGT AMBER. RT ENG EEC SYSTEM STATIC TEST SHOWS NO EXISTING FAULTS IAW AMM 73-21-00-740-801-N00.
Earlier reports · 1996–2025 · 187 reports
2025
Part: ENGINE — SMOKE (NR 2) · airframe 105,717 hrs · 19,098 cycles
ON TAKE OFF AND CLIMB, ACFT REPORTED BLACK SMOKE FROM RT ENG. ALL INDICATIONS NORMAL. CREW REPORTED THAT ALL ENGINE PARAMETERS OIL QTY, PRESSURE & TEMPS NORMAL, NO STS / EICAS MSG. NO ODOR / SMELL IN FLIGHT DECK OR CABIN. CURRENTLY NO AHM FAULTS. INSPECTED ENG NR 2 FOR OIL LEAKS IAW FIM 71-08 TASK 819. NO LEAKS NOTICE ACFT OKAY TO CONTINUE.
Part: NONE — NONE (NONE) · airframe 105,638 hrs · 19,079 cycles
CREW REPORT ODOR THROUGH HALF THE FLIGHT. INSPECTED SMOKE IN CABIN IN REF AMM TASK 05-51-58-800. ACCOMPLISH STEPS A, B, AND PART C BEFORE ENGINE RUN. FOUND NO SMOKE OR ELECTRICAL ODOR. INBOUND CREW STATED PASSENGER VAPE PEN MALFUNCTION DURING DEPLANE. NO FURTHER MX ACTION REQUIRED. CONSULTED WITH TOMC. SMOKE ODOR FORM.
2024
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 DR R2 M33098 EMER LT BATT CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2599975 DR R2 M33098 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 DR L4 EMER LT BATT CHARGER M33407 TEST FAIL TRANSFER REF NON - ROUTINE WO.2572027 DR L4 M33407 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 L3 DR M33400 BATT DEEP-CYC PACK CAPACITY FAIL TRANSFER REF NON - ROUTINE WO.2600244 DR L3 M33400 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 L3 DR M33405 EMER LT BATT DEEP-CYC PACK CAPACITY CHK FAIL TRANSFER REF NON - ROUTINE WO.2600255 DR L3 M33405 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 DR L3 M33405 EMER LT BATT CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2599966 DR L3 M33405 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 DR L3 M33400 EMER LT BATT CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2600317 DR L3 M33400 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06 .
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 L2 DR M33096 EMER LT BATT DEEP-CYC PACK CAPACITY CHK FAIL TRANSFER REF NON - ROUTINE WO.2600311 DR L2 M33096 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: BATTERY PACK — NO TEST (DOOR L3, M33406) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 L3 DR M33406 EMER LT BATT TEST FAIL TRANSFER REF NON - ROUTINE WO.2600109 DR L3 M33406 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 R2 DR M33098 EMER LT BATT DEEP-CYC PACK CAPACITY CHK FAIL TRANSFER REF NON - ROUTINE WO.2600305 DR R2 M33098 EMER LT REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
SUPPORT TASK - DR L4 EMER LT BATT M33407 TEST FAIL. TRANSFER REF NON - ROUTINE WO.2572051 AND DR L4 M33407 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
B777-33-3-7019 DR R2 M33097 EMER LT BATT TEST FAIL. TRANSFER REF NON - ROUTINE WO.2600103 DR R2 M33097 EMER LT BETTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 100,088 hrs · 17,774 cycles
EMERGENCY LIGHT BATTERY CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2599986 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06
Part: SKIN — CRACKED (LH UNDERWING) · airframe 100,088 hrs · 17,774 cycles
SUPPORT TASK - EA 5310-07557 OP 002 - 1EA CRACK FOUND ON LH UNDERWING LONGERON FTG FX SKIN FASTENER HOLE, CRACK RUNNING TO AFT DIRECTION APPROX 0.125" IN DEPTH STARTING FROM I/B EDGE TRANSFER REF NON - ROUTINE WO.2622006 AND ORIG BY V924734 RON DOUBLER INSTALLATION PER THE LATEST REVISION OF ECRA 5330-07 179 PART 2 ON OR BEFORE 15JAN26. REPAIRED PER ECRA 5330-07179 PART 1 INTERIM REPAIR. WORK PERFORM ED HAECO HKG NON - ROUTINE WO.2622006. INSPECT LH UNDERWING LONG OK TO DIP PART 1 INTERM REPAIR LH UNDERWING LONGERON FTG FX SKIN TOMC-APPROVAL FROM SC1ELBYC COMMENT FASTENER HOLE. INSPECT LH UNDERWING LONGERON DOUBLER INSTALLATION PER THE LATEST REV OF ECRA 5330-07179 PART 2 ON OR BEFORE 15-JAN-2026 . PER ECRA 5330-07179.
2023
Part: LONGERON — CRACKED (LH WING) · airframe 100,088 hrs · 17,774 cycles
SUPPORT TASK - EA5310-07557 OP002 (AD2019-11-02) LH BS1035 UNDERWING LONGERON CTR SECTION FRONT SPAR LWR CHORD 2EA HOLE CRACK FOUND TRANSFER REF NON - ROUTINE WO.2618004 LH BS1035 UNDERWING LONGERON CTR SECTION FRONT SPAR LWR CHORD (2EA) HOLE CRACK REPAIRED IAW SRM57-10-10-2R-1 REPAIR 1 FIG202
Part: SKIN — DAMAGED (R2 DOOR) · airframe 100,088 hrs · 17,774 cycles
SUPPORT TASK - EA5100-02345 REV E OP19 CAB R2 DR EXT SKIN DOUBLER FOUND AT AFT LWR CORNER WITH NO RECORD FOUND TRANSFER REF NON - ROUTINE WO.2571519 EA5100-02345 REV E OP19 CAB - R2 DR EXT SKIN DOUBLER AT AFT LWR CONER WITH NO RECORD FOUND. THE LOCATION AREA REPAIRED IAW SRM52-10-01-2R-8 REPAIR 8.
Part: SKIN — DAMAGED (L4 DOOR) · airframe 100,088 hrs · 17,774 cycles
SUPPORT TASK - EA 5100-02345 REV E OP19, CAB - L4 DOOR EXT SKIN DOUBLER FOUND AT AFT LOWER CORNER WITH NO REPAIR RECORD FOUND. TRANSFER REF NR HX WO.2571459 . EA5100-02345 REV E OP19 CAB - L4 DR EXT SKIN DOUBLER AT AFT LWR CORNER WITH NO REPAIR RECORD. THE LOCATION REPAIRED IAW SRM52-10-01-2R-8 REPAIR 8.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 99,993 hrs · 17,750 cycles
DESCENDING OUT OF 12K SLIGHT BURNING SMELL ON FD AND FIRST CLASS SMOKE FORMS ATTACHED PERFORMED SMOKE/ODOR IN FLIGHTDECK/CABIN INSP REF AMM 05-51-58. SMELL DISSIPATED AS TROUBLE SHOOTING CONTINUED. COULD NOT DUPLICATE, NO DEFECTS NOTED.
Part: VACUUM SYS — LEAKING (AFT LAV) · airframe 99,016 hrs · 17,513 cycles
*THIS IS A SUPPLEMENTAL REPORT TO THE ORIGINAL REPORT, WITH THE SAME CONTROL NUMBER, CIRCULATED ON 06/30/2023*. ACFT RTF WITH MULTIPLY LAVS WEAK OR NO FLUSH. WASTE TANK #2: 1L-OUTBOARD, 2L-OUTBOARD & 3L-AFT. WASTE TANK #3: 3R-FWD & 2R-OUTBOARD LAVS WAS ALSO WEAK OR NO FLUSH ON THE GROUND OPENED PIT PANEL TO AND FOUND INLET TO #2 TANK CRACKED RIGHT REMOVED DAMAGED AFT WASTE TANK. REF. AMM 38-32-11-000-801. ABOVE THE TANK. #3 TANK HAS A CRACKED INLET LINE AND TANK ADD EMP:144704 PUNCTURES WHERE THE INLET LINE MEETS THE TANK AND AT THE BOTTOM OF THE TANK. IT ALSO LOOKS LIKE T#3 TANK HAS MOVED. FORWARD. WAITING FOR O-RINGS FOR UPPER FWD AND AFT INLET CONNECTIONS AND CONNECTION AND SEAL ON LOWER DRAIN CONNECTION. NEED PERFORM OP SEAL PLATE FOR LOWER WASTE DRAIN CONNECTION.REF. AMM AND LEAK CHECK. REF. AMM 38-32-11-00-801. 38-32-11-400-801. PARTS USED: 26-3832-9-9001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1720301 SN OFF 6157 INSTALLED NEW WASTE TANK; CONNECTED RINSE WATER LINE; INSTALLED REMOVED AFT WASTE TANK. DISCONNECTED ALL CONNECTIONS FROM MIDDLE REINSTALLED AFT WASTE TANK; CONNECTED RINSE WATER AND UPPER UPPER POLAR CAP; INSTALLED LCM AND CONNECTED TO LEVEL SENSORS; WASTE TANK EXCEPT FOR 6 MOUNT BOLTS.REF: TASK 38-32-11-000-801 POLAR CONNECTION. INSTALLED LCM AND WIRINGS. NEED TO RESEAL AFT NEED TO RESEAL AFT SENSOR COVER AND SECURE LCM WIRINGS. NEED TO SENSOR COVER AND SECURE SENSORS WIRINGS. NEED TO DRILL HOLES TO DRILL HOLES ON FWD MOUNTING PLATE TO MOUNT UPPER SENSOR WIRING. MOUNT FWD SENSRO WIRE. WAITING FOR O-RING FOR AFT UPPER INLET ADD EMP:144704 TANK, WASTE, VA OFF 26-3832-9-9001 6157 ON 26-3832-9-9001 8344 COMPLETED # 3 WASTE TANK INSTALLATION REF AMM 38-32-11-400-801 REPLACED LOWER POLAR CAP AND SEALS ON MID TANK. PUMPED IN 1.5 G AND LEAK CHECKED ALL 3 TANKS. NO 2 WASTE TANK FAILED LEAK CHECK. OF WATER AND FOUND MULTI LEAKS COMING FROM TANK BOTTOM NECK TANK LEAKING AT LOWER LARGE V CLAMP. AREA. MID. TANK MUST BE REPLACED. ADD EMP:139320. REMOVED AFT WASTE TANK AND MID WASTE TANK. INSTALLED AFT TANK IN MID POSITION AND INSTALLED LOANED TANK IN AFT POSITION. NEED TO ACP LEAK AND OPERATIONAL CHECK. REF. AMM 38-32-11. PARTS USED: 99-3810-3-0069,QTY :1 26-3832-9-9001,QTY :2 ADD EMP:92851 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1713781 SN OFF 4039 TANK, WASTE, VA OFF 26-3832-9-9001 4039 ON 26-3832-9-9001 0521. PERFORMED OPERATIONAL LEAK CHECK OF CENTER AND AFT . LAV. TANKS. LEAK CHECK GOOD. ALSO PERFORMED CHECK OF ALL LAVS . ALL LAV. CHECKED GOOD .
Part: ENGINE — DAMAGED (LEFT) · airframe 98,791 hrs · 17,463 cycles
BIRD HIT LEFT ENG ON TO EGT WENT INTO RED. PERFORMED VISUAL INSPECTION OF #1 ENGINE AND FOUND BIRD WAS INGESTED INTO CORE AT 4 OCKLOCK POSITION OF ENGINE FIRST STAGE INLET GUIDE VANES, REQUIRES FURTHER INSPECTION. SDR REPORTING EGT PIC UPDATE. REMOVED AND REPLACED # 1 ENG IAW TASK CARD # 27-0525-8-0225 OPS AND LEAK CHECK GOOD ON GRD RUN. ORIG SUBMISSION DATE: 06/05/2023.
Part: STEERING SYS — NONE (L MLG) · airframe 97,930 hrs · 17,231 cycles
MAIN GEAR STEERING CAUTION CAUSED TO-CONFG WARNING ON THE ROLL FOUND LEFT MAIN STEERING NOT LOCKED. CYCLED STEERING SYSTEM, CREW STATES NO HIGH ENERGY STOP AFTER T.O. CONFIG MSG. AS COMPLIED WITH MELCARD 3253A. BOTH MAIN GEAR CYLINDERS NOW LOCKED. REQUEST MEL CARD 3253A. PRECAUTION BRAKE TEMPS ALL SHOW APPROX .01. REF AMM 05-51-14. MAIN GEAR STEERING SYSTEM (INCLUDING INDICATION) INOP. LEFT MAIN GEAR STEERING ACTUATOR HAS NO OUTPUT. M&E P/N 27-3252-9-0004 NIS AT SFO. REPLACED L/H MAIR GEAR STEERING ACTUATOR PER AMM32-53-03-000-801 GRD CHECK GOOD MESSAGE CLEARED ADD EMP:U027978 U028826 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1770574 SN OFF 0686 ACTUATOR, MLG, OFF 27-3252-9-0004 0686 ON 27-3252-9-0004 0688
2022
Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 97,094 hrs · 17,016 cycles
DOOR 1L AFTER EMERGENCY LIGHT POWER PACK CAN NOT BE CHARGED UP. PERFORMED T/S AS PER FIM 33-51 TASK 8 OPERATION TEST AND RESULT NORMAL AS PER AMM 33-51-00-710-801 REV 6 REV96. REPLACED DOOR 1L AFT BATTERY PACK AS PER AMM 33-51-06-9 96. 6-802 REV96. REPLACED THE POWER SUPPLY AT DOOR 1L AFTER POSTION AS PER AMM 33-51-06-960-803 REV96. PERFROMED EMERGENCY LIGHTS
Part: BATTERY — INOPERATIVE (LH 2 DOOR) · airframe 97,094 hrs · 17,016 cycles
OPERATIONAL TEST FND L/H DOOR NO.2 TO 25ABC CEILING EMER LIGHT INOP, REFER TO HAECO NR NO.9494136, ORIGINATED BY EMP V903529, SPEC NO. B777-33-3-7019. PERFORMED BY EMP V905416 IDT BY TA393, REPLACED L/H NO.2 DOOR EMERGENCY LT BATTERY, PERFORMED OP TEST, THE RESULT WAS NORMAL REF AMM 33-51-06-960-802 REV 96.
2021
Part: STRINGER — CORRODED (ZONE 100) · airframe 96,170 hrs · 16,782 cycles
LONGERON STRINGER 1937 TO 1958,STR L42 TO L42 CORROSION. PART: LONGERON STRINGER, LOCATION: STA/FRAME 1937 TO 1958, STRINGER STR L42 TO L42. BULK CARGO STA 1937 TO 1958 LT STR 42 ST RINGER REPAIRED, AS PER SRM 53-70-03-2R-1 REV 84 AND ECRA 5312-01 142 REV. DETAIL REF ATT SWS RII BY TA369.
Part: DOUBLER — NOT REPORTED (FUSELAGE) · airframe 96,170 hrs · 16,782 cycles
AFT LOWER CORNER AREA FOUND A DOUBLER, EA5100-02345 REV E OP10. PERFORMED AFT CARGO DOOR AFT LOWER CORNER AREA EXITING DOUBLER REMOVED, AS PER SRM 51-40-02 REV 84 AND REPAIRED AS PER ECRA 5209-01063 REV. RII BY TA369
Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 96,170 hrs · 16,782 cycles
PERFORM EMERGENCY LIGHT OPERATION CHECK FOUND BATTERY DOOR R4 M3 3408 INOPERABLE. REPLACED THE M33408 EMERGENCY LIGHT BATTERY PACK AT DR R4 INSTALLATION TEST FOUND NORMAL, REF AMM 33-5 1-06-960-802 REV 90.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 96,170 hrs · 16,782 cycles
PERFORM EMERGENCY LIGHT OPERATION CHECK FOUND BATTERY DOOR R3 M3 3404 INOPERABLE. REPLACED M33404 EMERGENCY LIGHT BATTERY PACK INSTALLATION TEST FOUND NORMAL AT DR R3M, REF AMM 33-51-06 -960-802 REV 90.
Part: STRUCTURE — CRACKED (FUSELAGE) · airframe 96,170 hrs · 16,782 cycles
FUS BS 1035 RT UNDERWING LONGERON LOWER CHORD FOUND CRACK. FUS BS 1035 RT UNDERWING LONGERON LOWER CHORD REPAIRED, AS PER SRM 57-10-10 REPAIR 1 FIG 202 REV 84 AND EC RA 5710-02763 REV - RII.
Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 96,170 hrs · 16,782 cycles
PERFORM EMERGENCY LIGHT OPERATION CHECK FOUND EMERGENCY LIGHT BATTERY (DOOR R1 M33094/R3 M33404/R4 M33408) TOTAL 3 EA INOPERABLE. REFER NON-ROUTINE NR 9422420 SPEC NR B777-33-3-7030. REPLACED M33094 M33404 M33408 EMERGENCY 1-06-960-802 REV 90 R1 P/N ON AD-D717-01-100 S/N ON 253353, P/N OFF D717-01-100 OFF S/N 203457 R3 ON P/N ADD717-01-100 ON S/N 25 3367, OFF P/N ADD717-01-100 OFF S/N 141465. LIGHT BATTERY PACK, INSTALLATION TEST RESULT ''PASS'', REF AMM 33-5 /N 200913. R4 ON P/N ADD717-01-100 ON S/N 231846, OFF P/N D717-01-100 OFF S.
2020
Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 96,170 hrs · 16,782 cycles
PERFORM EMERGENCY LIGHT OPERATION TEST FOUND DOOR L2 M33099 AND R3 M33401 EMERGENCY LIGHT BATTERY CHARGER INOPERATE. REPLACED THE DOOR L2 M33099 AND R3 M33 401 EMERGENCY LIGHT BATTERY CHANGER AND PERFORM EMERGENCY LIGHT OPERATION TEST, FOUND NORMAL, REF AMM 33-51-06-960-803 REV 90.
2018
Part: RELAY — UNSERVICEABLE (FUEL SYSTEM) · airframe 88,800 hrs · 15,144 cycles
AFTER ENGINE SHUTDOWN, ENG FUEL VALVE RT STATUS MESSAGE. T/S CARRIED OUT AS PER FIM 73-22-00-810-802-N00 ENGINE FIREWALL DISCONNECT TO FMU CONNECTORS AND WIRING INSPECTED AND CONNECTORS CLEANED. ENGINE CORE HARNESS BETWEEN D71024P AT ENG DISCONNECT AND D71074J AT ENGINE CORE 3 O'CLOCK POSN. REPLACED DUE TO BEING IN POOR CONDITION. RELAYS K76202 AND K76207 REPLACED WITH REF TO 7730131 RAISED FOR EEC CONNECTOR REFIT. ENGINE SHUT DOWN NORMALLY WITH NO FUEL VALVE MESSAGE. ENGINE WET MOTOR AND GROUND IDLE ACCOMPLISHED.
Part: UNKNOWN — ODOR (CABIN) · airframe 88,766 hrs · 15,138 cycles
PER F-A, BURNING SMELL NOTED AT ROWS 23-28 AND 46-49. SMELL DISSIPATED BUT LATER RETURNED. MULTIPLE PAX CELL PHONE CHARGERS EXTREMELY HOT TO THE TOUCH. UNPLUGGED ALL AND TURNED OFF IN SEAT POWER AND SMELL DISAPPEARED. NO BREAKERS POPPED. MAINTENANCE ACCOMPLISHED AMM 05-51-58-800-801C3 STEP2 A & B, NO OBVIOUS DEFECTS OR ABNORMALITIES FOUNDTHE AIRCRAFT RELEASED BACK TO SERVICE. ALSO REFER LP 7684549.
2017
Part: STRUCTURE — CRACKED (FUSELAGE) · airframe 85,955 hrs · 14,577 cycles
SUPPORT TASK (AD 2016-09-01) EA 5380-01113 O P 002 RT BS 2370 PIVOT BULKHEAD FWD CHORD FOUND CRACKED GREATER THAN 0.160 INCHES. PLS ACCOMPLISH OP012 ACCOMPLISHED AS PER EA 5380-01113 OP 012.
Part: STRUCTURE — CRACKED (BS 2370 BULKHEAD) · airframe 85,955 hrs · 14,577 cycles
RT BS 2370 PIVOT BULKHEAD FWD STRUCTURE FOUND CRACKED. REPAIRED IAW EA 5380-01113, OP 012.
Part: SPLICE — CRACKED (FUSELAGE) · airframe 85,955 hrs · 14,577 cycles
SUPPORT TASK EA 5380-01113 OP 002 (AD 2016-0 9-01) RT BS 2370 PIVOT B/H SPLICE ANGLE FOUND CRACK. ACCOMPLISHED AS PER EA 5380-01113 OP 012.
Part: STRUCTURE — CRACKED (FUSELAGE) · airframe 85,955 hrs · 14,577 cycles
SUPPORT TASK (AD 2016-09-01) EA 5380-01113 O P 001 LT BS 2370 PIVOT BULK HEAD FWD CHORD FOUND CRACKED GREATER THAN 0.160 INCHES. PLS ACCOMPLISH OP 011 ACCOMPLISHED REFER EA 5380-01113 OP 11.
Part: SKIN — CRACKED (BS 2221) · airframe 85,952 hrs · 14,576 cycles
SKIN HAD TWO CRACKS WERE FOUND AROUND FASTENERS AT BS 2221.65, BETWEEN STRINGERS 9 TO 10L. TRIMMED THE AREA IAW DRAWING 624W0013, SHT 2, REV B. HFEC INSPECTION CARRIED OUT IAW NTM PART 6, 51-00-01, PROC 2. NO CRACK FOUND.
Part: SKIN — CRACKED (BS 2195) · airframe 85,952 hrs · 14,576 cycles
FOUND TWO CRACKS IN THE SKIN AT BS 2195.75 BETWEEN STR 6 TO 8L. TRIMMED THE AREA IAW DRAWING 624W0013, SHT 1, REV B. HFEC INSPECTION CARRIED OUT IAW NTM PART 6 51-00-01, PROC 2. NO CRACK FOUND.
Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 85,952 hrs · 14,576 cycles
CABIN DOOR 3R EMERG LIGHT DM 33401 BATTERY PACK FOUND LOW VOLTAGE CABIN DOOR 3R EMERG LIGHT DM33401 BATTERY PACK AND CHARGER REPLACED OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06.
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 85,952 hrs · 14,576 cycles
L3 DOOR EMERGENCY LIGHT BATTERY PACK FOUND LOW VOLTAGE. THE BATTERY PACK AND CHARGER WERE REPLACED AND OPS TESTED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 85,952 hrs · 14,576 cycles
CABIN DOOR 3L EMERG LIGHT BATTERY PACK DM 33405 FOUND LOW VOLTAGE. CABIN DOOR 3L EMERG LIGHT DM33405 BATTERY PACK AND CHARGER REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06.
Part: PRESSURE DECK — CRACKED (FUSELAGE) · airframe 85,952 hrs · 14,576 cycles
PRESSURE DECK WEB FOUND CRACK AT STA 1287 BETWEEN LBL 18.3 AND 25.7. PLEASE ACCOMPLISH OP 02 EA5300-01502 OP 01 HORIZ PRESSURE DECK WEB STA 1287 BTN LBL 18.3 AND LBL 25.7 CRACKED AREA TRIMMED OFF AS PER SRM 51-10-02 AND DWG 624W0008 SHT 8 REV A HFEC INSPECTION CARRIED OUT AS PER NTM PART 6 51-00-01 PROC 2 RESULT NO CRACK FOUND AT TRIMMED AREA. TRIMMED AREA PLUG INSTALLED AS PER EA 5300-01502 OP02 AND DRAWING 624W0008 SHT 8 REV A.
Part: PRESSURE DECK — CRACKED (FUSELAGE) · airframe 85,952 hrs · 14,576 cycles
HORIZONTAL PRESSURE DECK WEB FOUND CRACK AT 1287 BETWEEN RBL 18.3 AND 25.7. HORIZ PRESSURE DECK WEB STA1287 BTN RBL18.3 & RBL 25.7 CRK AREA TRIMMED OFF AS PER SRM 51-10-02& DWG642W0008 SHT8 REV A. HFEC INSP C/O AS PER NTM PT6,51-00-01 PROC2 RESULT NO CRK FND AT TRIMMED AREA. TRIMMED AREA PLUG INSTL AS PER EA 5300-01502 OP02 AND DWG 624W0008 SHT 8 REV A.
Part: FLASHLIGHT — INOPERATIVE (L1 DOOR) · airframe 85,365 hrs · 14,459 cycles
1L EMER FLASHLIGHT NOT BLINKING. REPLACED FLASHLIGHT, OPS CHECK NORMAL
2016
Part: CLAMP — UNSECURE (PLENUM DUCT) · airframe 82,508 hrs · 13,854 cycles
LOSS OF CABIN ALTIITUDE CONTROL, CABIN CLIMBING ERRATICALLY. EMERGENCY DESCENT AND DIVERSION. BLEED LOSS WING R EICAS ADVISORY BLEED AIR SUPPLY VALVES ARE LATCHED CLOSED OR THE RESPECTIVE SWI TCHES ARE OFF, SO THAT BLEED AIR IS NOT SUPPLIED TO THE RT WAI, RT PACK, AND RT HYDRAULIC RESERVOIR PRESSURIZATION. FOUND PLENUM DUCT SEALS FAILED ON BOTH LEFT AND RIGHT PACKS. REP LACED AND OPS CHECKED GOOD. MESSAGES CLEARED.
Part: UNKNOWN — ODOR (LAVATORY) · airframe 82,343 hrs · 13,822 cycles
CREW REPORTED AN ODOR FROM LAVATORY 101 THAT WAS STRONG AND SMELLED LIKE IODINE. ACCOMPLISHED AN INSPECTION OF MIRROR LIGHTS, WATER HEATER, AND THE FLUSH CONTROL ASSY. NO EVIDENCE OF ELECTRICAL ODOR OR INDICATION OF OVERHEATING. ALSO INSPECTED UNDER THE LAVATORY SINK AND TOILET SHROUD, COULD NOT IDENTIFY ANY SOURCE OF ODOR. AFTER A FULL CLEANING OF THE AFFECTED LAVATORY, RESIDUAL ODOR DISIPATED.
2015
Part: CHILLER — FAULTY (GALLEY) · airframe 76,704 hrs · 13,062 cycles
ON TAXI OUT, JUST PRIOR TO TAKEOFF, HAD A BURNING ELEC SMELL WITH VISIBLE SMOKE NEAR A VENT FACING DOOR 4L. INSPECTED APU AIR SUPPLY DUCT, NO LEAKS PTT7046004. INSPECTED AFT GALLEY CHILLERS & FOUND C52 WITH INCORRECT EXHAUST PORT INSTALLATION PTT7046002. ALSO FOUND ONE INSULATION BLANKET LOOSE & BLOWING DUST TO THE VENT. BLANKET CORRECTED PTT7046003. RAN ENGS WITH THE SAME CONFIGURATION AS FLIGHT CREW USED FOR TAXI, NO SIGNS OF SMOKE OR DIFFERENT SMELL. AIR VENT BY DOOR 4L SLIGHTLY WARMER THAN NORMAL, COOLED AFTER CHILLERS SHUT DOWN. BOTH CHILLERS PLACED ON MEL.
2013
Part: PUMP — INOPERATIVE (FUEL SYSTEM) · airframe 71,396 hrs · 12,342 cycles
RT CTR MAIN FUEL PUMP WILL NOT OPERATE.
Part: LATCH — BROKEN (NR 2 COWLING) · airframe 71,302 hrs · 12,330 cycles
NR 2 LT CORE COWL FWD LOWER OTBD LATCH BROKEN. LATCH REMOVED, MOUNTING HARDWARE SECURED TO COWL. PN ON LATCH IS TL10622-111. REPLACED LT HOOP TIE LATCH.
Part: CABLE — FRAYED · airframe 69,932 hrs · 12,134 cycles
FOUND THE PRE SELECT FILL OVERFILL CABLE BAD. THE CABLE END IS FRAYED AND CABLE IS VERY LOOSE. WATER SERVICE IS NORMAL FROM FWD WATER SERVICE PANEL (ELECTRIC) PROBLEM IS WITH AFT (MANUAL CABLE) SERVICE PANEL. COMPLIED WITH MEL. OPS CKS GOOD.
Part: VALVE — FAULTY (NR 2) · airframe 69,640 hrs · 12,093 cycles
ENGINE CONTROL RT STATUS MESSAGE AFTER ENGINE START. AHM REPORTING FAULT 75-60482 (2.9 STABILITY BLEED NOT IN COMMANDED POSITION). CLEARED MESSAGE, FAULT RETURNED WHEN ENGINE WAS RESTARTED AND IDLED FOR A FEW MINUTES. REPLACED VALVE IAW MM 75-32-05. RAN ENGINE, OPS CHECKED GOOD.
Part: TERMINAL BLOCK — OUT OF TOLERANCE (NR 2 IDG) · airframe 69,514 hrs · 12,075 cycles
NR 2 IDG TERMINAL BLOCK ASSY HAS TWO LOOSE LUGS. REPLACED NR 2 IDG TERMINAL BLOCK ASSY IAW AMM.
Part: FILTER — CLOGGED (RT ENG BLEED) · airframe 69,290 hrs · 12,045 cycles
RT ENGINE 2.9 STAB BLEED, FOUND PS3 FILTER CLOGGED, REPLACED FILTER IAW AMM. ACP FIM TASK 71-08 TASK 828,2.9 BLEED VALVE. OPS CHECKED OK.
Part: OXYGEN BOTTLE — EMPTY (CREW) · airframe 69,275 hrs · 12,043 cycles
4R CREW O2 EMPTY. REPLACED O2 BOTTLE, NO DEFECTS NOTED.
Part: ENGINE — SURGES (LEFT) · airframe 67,984 hrs · 11,856 cycles
ON ARRIVAL FLT 941-29. CREW REPORTED THE LEFT ENGINE SURGED AND RUMBLED ON THREE DIFFERENT OCCASIONS. ALL THREE AT FLT LVL 28.0. AUTOTHROTTLES ON. ENGINE HAD NO EXCEEDENCES, EGT REPORTED TO BE HIGHER AND CLIMBING DURING ALL THREE EVENTS. ALSO DURING TAXI IN EGT ABOUT 70 DEG HIGHER ON LEFT ENGINE. ENGINE WAS NOT SHUTDOWN. ENGINE REPLACED.
Part: ENGINE — SURGES (LEFT) · airframe 67,984 hrs · 11,856 cycles
LEFT ENGINE SURGES. NOTICEABLE ENGINE VIBRATION DESCENDING THRU FL180. LEFT ENGINE VIBRATION 2.4, RIGHT ENGINE VIBRATION .5. REPLACED LT ENGINE.
2012
Part: BATTERY — FAULTY (MAIN) · airframe 67,320 hrs · 11,762 cycles
DURING ACFT REPOSITIONING, BATTERY CHARGER AND MAIN BATTERY STATUS MESSAGE DISPLAYED. REMOVED AND REPLACED MAIN BATTERY AND BATTERY CHARGER AS PER AMM. OPS AND INDICATION NOW NORMAL.
Part: DATA UNIT — FAILED (SATCOM) · airframe 67,098 hrs · 11,731 cycles
CREW REPORTED SATCOM DIRECTORY MISSING NUMBERS, AND IS BLANK. REPLACED SATCOM DATA UNIT PER MM AND OPS NORMAL.
Part: LINE — LOOSE (WATER SYSTEM) · airframe 66,913 hrs · 11,703 cycles
CREW REPORTS MOTOR NOISE AND VIBRATION IN DOOR 4 FLOOR AREA. ATTEMPTED TO ISOLATE WITH PACKS, GASPER, CHILLERS, EQUIP COOLING, ETC. NO HELP. RETURNED TO GATE. WATER COMPRESSOR NOISE OBSERVED AT GATE. NOISE GONE AFTER DEACTIVATION. CB G12 P320 PANEL PULLED AND COLLARED. REPLACED COMPRESSOR. VIBRATION GONE COMP WON'T SHUT OFF. SUSPECT PRESSURE SWITCH LOB PRESSURE SWITCH. REPLACED SWITCH, COMP STILL WON'T SHUT OFF. FOUND LOOSE AIR LINE NEAR THE AIR COMPRESSOR. OPS CHECKS NORMAL.
Part: ACTUATOR — FAULTY (RT FLAPERON) · airframe 66,555 hrs · 11,651 cycles
FLIGHT CONTROL SYSTEM EICAS MESSAGE. NEEDS RIGHT INBOARD FLAPERON ACTUATOR REPLACED. REPLACED RIGHT FLAPERON INBOARD ACTUATOR AS PER AMM. ALL REQUIRED MAT TEST PASSED OPS AND LEAK CHECK ACCOMPLISHED. NO LEAKS NOTED, ALL INDICATIONS NORMAL NOW.
Part: MECHANISM — DEFECTIVE (R2 DOOR) · airframe 66,157 hrs · 11,587 cycles
DOOR FLT LOCK 2R STATUS MESSAGE, REPEAT GRIPE. DOOR OPENS AND CLOSES NO TROUBLE. REPLACED FLIGHT DOOR LOCK MECHANISM.
Part: BATTERY — FAILED (APU) · airframe 65,929 hrs · 11,556 cycles
APU BATTERY FAILED. REPLACED BATTERY. APU BATTERY WEAK MESSAGE CLEARED. THEN APU BATTERY CHARGER INTERNAL FAULT MESSAGE BECAME ACTIVE. REPLACED BATTERY CHARGER MESSAGE CLEARED. OPS CHECKS GOOD. APU BATTERY MSG REOCCURED.
Part: CONTROL UNIT — NO TEST (FLT CONTROLS) · airframe 64,321 hrs · 11,324 cycles
OP CHECK OF ACE MONITORING FUNCTION PER 3SV FAILED. REPLACED L1 ACE, NO HELP. SWAPPED L1 AND L2 ACE, LRU TESTS PASSED, ACE MONITOR TEST PASSED.
Part: BTMS — FAILED (BRAKE SYSTEM) · airframe 63,957 hrs · 11,274 cycles
BRAKE TEMP SYS BRAKE TEMPERATURE MONITOR SYSTEM HAS FAILED. CAUSING PARTIAL OR TOTAL LOSS OF BRAKE TEMPERATURE INDICATION OR LOSS OF BUS INPUTS FROM THE BRAKE TEMPERATURE MONITOR UNIT. REPLACED BTMU, OPS CHKS NORMAL.
Part: ACTUATOR — LEAKING (LT SPOILER) · airframe 63,623 hrs · 11,227 cycles
LEFT WING NR 4 SPOILER ACTUATOR IS LEAKING. REMOVED NR 4 CABLE CONTROLLED SPOILER POWER UNIT FROM START TO 2E. NEED TO COMPLETE FROM 3A TO FINISH.
Part: ANTI-ICE VALVE — INOPERATIVE (NR 2 ENGINE) · airframe 63,620 hrs · 11,226 cycles
NR 2 ENG ANTI-ICE VALVE INOP. INSTALLED NEW NR 2 ENG ANTI-ICE VALVE PER MM AND ACCOMPLISHED ENGINE RUNNING TEST ON MAT PER MM. CHECKS GOOD.
Part: HEAT SHIELD — WORN (NR 1 ENGINE) · airframe 63,623 hrs · 11,227 cycles
NR 1 ENG HEAT SHIELD GAP STRIP WORN. STRIP NR 2 IS WORN PASS LIMITS. REMOVED AND PAR REINSTALLED REWORKED GATOR BACKS WITH 2 BOLTS ONLY ON ALL HEAT SHIELDS 1 HEAT SHIELD IS STILL REMOVED. REPLACED NR 2 THRU NR 5 HEAT SHIELD PANS. COMPLETED INSTALL OF HEAT SHIELDS.
Part: AMU — INOPERATIVE (COCKPIT) · airframe 63,445 hrs · 11,202 cycles
CO-PILOTS SPEAKER IS INOPERATIVE. INSTALLED AMU; TESTS OKAY.
Part: AMU — INOPERATIVE (AUDIO SYSTEM) · airframe 63,441 hrs · 11,200 cycles
CAPTAIN'S AUDIO PANEL INOPERATIVE. REPLACED AMU, SYSTEM CHECKS NORMAL AT THE GATE.
Part: HEAT SHIELD — WORN (RT ENGINE) · airframe 63,388 hrs · 11,192 cycles
RT ENG HEAT SHIELDS & GAP COVER STRIPS WORN-DAMAGED OUT OF LIMITS. NR 2 PYLON AFT FAIRING NR 1 HEAT SHIELD NEEDS HILOK HOLES FOR COVER STRIP EDDY CURRENTED. HEAT SHIELD REMOVED AND COVER STRIP REMOVED. ACCOMPLISHED HFEC INSP OF HOLES, NO CRACKS FOUND. INSTALLED NR 1 PAN COVER STRIP. INSTALLED NR 1 AND NR 2 PAN ASSY. PANS NR 1 AND NR 2 FASTENERS NEED TO BE SEALED AND DAMS INSTALLED. SEALED FASTENERS AND LEVELING COMPOUND.
2011
Part: SLIDER — CRACKED (CABIN) · airframe 62,982 hrs · 11,136 cycles
SLIDER ASSEMBLY CRACKED AT SCREW HOUSING ON SEATS 21B-19E-21J AND 21H-20J-31K-31J. PART# 021-2097. REPAIRED 21B-19E-21J-21H- 20J-.
Part: CONTROL VALVE — FAILED (CABIN AIR) · airframe 62,905 hrs · 11,125 cycles
MAINT MESSAGE 21-24102 DISPLAYED WHEN DOING CABIN TEMP CONTROL BITE TEST. RIGHT UPPER FLOW CONTROL VALVE INOPERATIVE. REPLACED UPPER FLOW CONTROL VALVE PER MM, OPS CHECKED NORMAL.
Part: LATCH — BROKEN (THRUST REVERSER) · airframe 62,830 hrs · 11,115 cycles
NR 1 ENG, FWD REVERSER LATCH BROKEN. P/N TL10588-105, PCN 120-3070. IPC78-31-00A-020V. LATCH REMOVED AND BAGGED WITH BOLT IN AREA. REPLACED NR 1 ENG FWD REVERSER LATCH.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 62,830 hrs · 11,115 cycles
PBE DOOR 2L FOUND SOFT. REPLACED PBE.
Part: PBE — DAMAGED (R3 DOOR) · airframe 62,830 hrs · 11,115 cycles
PBE R3 DOOR FOUND SOFT. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 62,830 hrs · 11,115 cycles
PBE DOOR 3L FOUND SOFT. REPLACED PBE.
Part: PBE — DAMAGED (CABIN) · airframe 62,314 hrs · 11,045 cycles
PBE SOFT DOOR 2L. REPLACED PBE.
Part: PBE — DETERIORATED (CABIN) · airframe 62,314 hrs · 11,045 cycles
PBE SOFT DOOR 3R. REPLACED PBE.
Part: PBE — DAMAGED (CABIN) · airframe 62,314 hrs · 11,045 cycles
PBE SOFT DOOR 3L. REPLACED PBE.
Part: PBE — UNSERVICEABLE (L4 DOOR) · airframe 62,314 hrs · 11,045 cycles
PBE SOFT DOOR 4L. REPLACED PBE.
Part: PANEL — DAMAGED (LT WING) · airframe 62,171 hrs · 11,027 cycles
LEFT WING PANEL 511AB LEADING EDGE HAS THE FLAYED ALUMINIUM SURFACE SPLIT AND LIFTING. REMOVED PANEL, EVALUATED PER EVA 81406A. NO DELAMINATION NOTED. REBONDED AND TRIMMED PER DWG 116W2610 SHEET. 1 FL NOTES 4 AND 5.
Part: IDG — FAULTY · airframe 61,916 hrs · 10,992 cycles
LOSS OF RIGHT TRANSFER BUSS IN FLIGHT. DUE TO REPEATED LOSS OF RIGHT TRANSFER BUSS IN FLIGHT. REMOVED & INSTALLED RT IDG PER MM.
Part: CIRCUIT CARD — MALFUNCTIONED · airframe 61,907 hrs · 10,991 cycles
F/O FLIGHT INSTRUMENT BUSS NOT POWERED. STATUS MSG-2412050 ACTIVE DC INTER. REPLACED I-O CARD M24403A5. OPS NORMAL ON GROUND. MESSAGES CLEARED. ACFT OK FOR SERVICE.
Part: STRUCTURE — DAMAGED (FUSELAGE) · airframe 61,799 hrs · 10,977 cycles
AIRCRAFT INCURRED LIGHTNING STRIKES. FOUND LIGHTNING STRIKE BETWEEN STA'S 345 & 358 AT 2L FROM TOP CENTERLINE. MAINT TEXT: POSITION OF LIGHTNING STRIKE IS 9" FWD OF STA 320 ON STRINGER 3L. 1-4" INBD FROM FASTENER. STARTED BLENDING DAMAGE. REMOVED ADJACENT RIVET FOR ACCESS. :PERFORMED HFEC REF NDT 51- 00-02. NO DEFECTS NOTED. BLEND BEYOND LIMITS UNABLE TO REMOVE DAMAGE NEEDS REPAIR. REPAIRED REF SRM REPAIR NR 4 WITH CS BRILES RIVETS.
Part: CONTROL PANEL — FAULTY (COCKPIT) · airframe 61,799 hrs · 10,977 cycles
CENTER RADIO CONTROL OFF-SIDE TUNING LIGHT INOP. PER MEL NO PARTS ORD. REPLACED CTR RADIO CONTROL PANEL.
Part: STRAP — UNSECURE (LT MLG TRUNNION) · airframe 61,731 hrs · 10,968 cycles
FOUND LT MLG FWD TRUNNION UPPER STRAP OTBD ATTACH, LOWER OTBD BOLT NOT SECURED WITH RETAINING NUT. INSTALLED STRAP.
Part: SHUTOFF VALVE — INOPERATIVE (NR 1) · airframe 61,717 hrs · 10,966 cycles
NR 1 ENGINE BACK UP GEN AIR-OIL HEAT EXCHANGER COOLER VALVE INOP. REPLACED NR 1 ENG BACK UP GEN AIR-OIL COOLER VALVE REF AMM. PART BORROWED. PART 808900-1, PCN 645-9045, SERIAL F48080. CONTAINER NOT ON BOARD.
Part: ACTUATOR — FAULTY (L2 DOOR) · airframe 61,720 hrs · 10,967 cycles
STATUS MESSAGE: "DOOR FLIGHT LOCK 2L" MESSAGE EARLY IN FLIGHT. MESSAGE OCCURED PRIOR TO ELECTRICAL CHECKS, SO IT NEEDS TO BE CHECKED. REPLACED WITH NEW FLIGHT LOCK ACTUATOR AND FLIGHT LOCK CONTROL TEST OKAY.
Part: OIL TANK — LEAKING (NR 2 ENGINE) · airframe 61,720 hrs · 10,967 cycles
NR 2 ENG S/N 777027, FOUND SIGN OF OIL LEAKAGE AT PRESSURE TUBE (LP36) MATING SURFACE WITH OIL TANK FLANGE. REPLACED STRAINER AY. RAN ENGINE, STILL LEAKING 2 DROPS PER MINUTE, WITHIN LIMITS. NEW OIL TANK EN ROUTE. PCN 223-7100, 1 EA, LUBE OIL TANK FROM SHOP D52. REMOVED AND REPLACED NR 2 ENGINE OIL TANK. LEAK CHECK GOOD.
Part: BATTERY — DISCHARGED (MAIN) · airframe 61,717 hrs · 10,966 cycles
THE MAINTENANCE MESSAGE 24-50243 SHOWS RT FC BATTERY VOLTAGE LOW. REPLACED WITH NEW BATTERY & INSTALLATION TEST OKAY.
Part: IDG — FAULTY (RIGHT) · airframe 61,717 hrs · 10,966 cycles
MAT SHOWS MESSAGE "INTEGRATED DRIVE GENERATOR (R) EXCITER FIELD CURRENT IS OUT OF RANGE" (24-31612). REPLACED WITH NEW IDG, OPERATIONAL TEST OK PER AMM. POWER PLANT NR 3 OK.
Part: DISPLAY — INOPERATIVE (COCKPIT) · airframe 61,541 hrs · 10,939 cycles
LWR CENTER DISPLAY CTRL WENT BLANK JUST PRIOR TO PUSH. WORKED PRIOR TO THAT. REPLACED DISPLAY.
Part: SKIN — GOUGED (FUSELAGE) · airframe 61,492 hrs · 10,930 cycles
FOUND 2 GOUGES LOCATED APPROX 8FT FWD AND 10FT LEFT OF LOWER TCAS ANTENNA STATION 529, AND 48L. FOUND 1ST GOUGE APPROX 1.0" LONG AND .020" DEEP WITHIN A SHALLOW DENT OF 3.O" BY 4.0". THE 2ND GOUGE IS APPROX 0.75" LONG AND .003" DEEP. BLENDED BOTH GOUGES PER SRM. 1ST GOUGE MATERIAL REMOVED TO 0.25T (ALLOWABLE MAX LIMIT IS 0.15T). 2ND GOUGE REPAIRED PER SRM. ACP ALODINE TREATMENT. ACFT OK SERVICE FOR 50T PER SRM. PERFORMED HFEC ON EXTERIOR SKIN IN AND AROUND GOUGES, NO CRACKS NOTED. TREATED WITH ALODINE AND PRIMED PER EVA EVA-81055. MUST HAVE DETAILED VISUAL OF SKIN AREA AND UNDERLYING STRUCTURE EXTERNAL AND INTERNAL AND HFEC ACCOMPLISHED AT EVERY A CHECK STARTING WITH A07.
Part: OVERHEAT LOOP — FAULTY (LT ENGINE) · airframe 61,299 hrs · 10,904 cycles
OVERHEAT CIRCUIT L1 LEFT ENGINE OVERHEAT DETECTION CIRCUIT 1 FAILURE. STATUS MSG-2610131 ACTIVE ER HARD. HISTORY ON THIS ITEM SINCE 2010APR. PLS REVIEW PARTS REPLACED AND HISTORY. ACCOMPLISHED FIM 26-11 TASK 808. USING MEAGOHMMETER FOUND RESISTANCE VALUE LESS THAN MINIMIM SHOWN IN FIM (0 MEGOHMS). FOR LWR AFT FIRE DETECTOR M26005, NEED 566-0133 NIS AT LAX. CONFIRMED LOOP M26005 IS OUT OF TOLERANCE PER FIM. REPLACED LOOP M26005 AND PERFORMED TEST. NO MESSAGE IS PRESENT.
Part: ENGINE — OVERSERVICED (NR 2) · airframe 61,234 hrs · 10,895 cycles
RAMP REPORTED OIL LEAKING FROM NR 2 ENGINE. FOUND OIL LEAKING FROM DRAIN TUBE ON OIL SCUPPER DUE TO ENGINE OIL OVERSERVICE.
Part: TRANSCEIVER — UNSERVICEABLE (VHF COMM) · airframe 61,299 hrs · 10,904 cycles
PORTABLE VHF TRANSCEIVER PLASTIC TAMPER BAG SHOWS SIGNS OF TAMPERING. REPLACED VHF A3-AFT GALLEY.
Part: TUBE — DAMAGED (NR 2 NACELLE) · airframe 60,840 hrs · 10,834 cycles
NR 2 ENG PYLON INBD DRAIN TUBE BROKEN OFF. REPLACED BROKEN DRAIN TUBE WITH A TIME LIMITED REPAIR TUBE PER MT 54-UA3. A CF ITEM WAS CREATED FOR A PERMANENT REPAIR.
Part: FITTING — BROKEN (R4 DOOR) · airframe 60,410 hrs · 10,776 cycles
DOOR 4 RT AFT RT GIRT FITTING BROKEN OFF. REPLACED GIRT BAR FITTING MOUNT AND AFT ATTACH CASTING PER MM.
Part: DOOR — UNKNOWN (R4) · airframe 60,379 hrs · 10,772 cycles
DOOR 4R WILL NOT ARM. DOOR 4L OKAY. AT DOOR 4R THE THE RIGHT YELLOW DOOR ARM FLAG NOT IN VIEW. CYCLED DOOR SEVERAL TIMES AND ARMED SLIDE SEVERAL TIMES. OPS CHECKS NORMAL. BOTH YELLOW FLAGS IN VIEW WHEN ARMED.
Part: FSEU — FAULTY (NR 2) · airframe 60,119 hrs · 10,736 cycles
FLAP SLAT CONTROL 2 HIGH LIFT CONTROL LANE NR 2 HAS A FAULT STATUS. REPLACED NR 2 FSEU PER MM, OPS OKAY.
Part: HEAT EXCHANGER — LEAKING (LT ENGINE) · airframe 60,119 hrs · 10,736 cycles
FUEL SEEPAGE UNDER LEFT ENG. FUEL LEAKING FROM NR 1 ENG IDG AIR-OIL HEAT EXCHANGER, REPLACED PER MM. OPS NORMAL NO LEAKS.
Part: STRUT — CRACKED (NR 1 ENGINE) · airframe 59,978 hrs · 10,717 cycles
NR 1 ENG REAR TRANSITION AREA OUTER DUCT STRUTS 3 THROUGH 10 HAVE CIRCUMFERENTIAL CRACKS STRUT NR 3-.75, 4-.875,5-.625, 6-1.125, 7-.875, 8-1.125, 9-1.0, 0-.875. REF MM 72-54-01,PG. 605 THROUGH CRACKS ONE MAX PER EACH STRUT PERMITTED. MAX LENGTH 2 IN. REQUEST EG CONCURRENCE OF 600C VISUAL INSP INTERVAL. REF DISPOSITION LIMIT PAR (C) NR 1 SAME MM REF. CRACKS FOUND ON AK INSP. IN THE OUTER DUCT TRANSITION AREA AT THE REAR END OF THE STRUT. STRUTS 3-10 HAVE CIRCUMFERENTIAL CRACKS, STRUT (3) 0.75, (4) -0.875 (5) 0.625, (6)1.125, (7)0.875, (8)1.125,(9)1.0, 08489 (10) 0.875 INCH IN LENGTH. CRACKS ARE IN LIMITS PER MM72-54-01 G 605. THESE CRACKS WERE PREVIOUSLY COVERED BY CF624.
Part: BATTERY — INOPERATIVE (EMERGENCY LIGHT) · airframe 59,205 hrs · 10,604 cycles
EMERGENCY CEILING LIGHTS AT 12,13 AND 15 RT ARE OUT. REPLACED BATTERY M33098 ABOVE DOOR 2R, LIGHTS ALL OP CHECKED GOOD.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 59,205 hrs · 10,604 cycles
EMERGENCY LIGHT AT SEAT 20C IS OUT. RELAMPED, OPS CHECKS GOOD.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 59,205 hrs · 10,604 cycles
CEILING LIGHT ABOVE SEAT 24J IS INOP. RELAMPED, OPS CHECKS GOOD.
Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 59,205 hrs · 10,604 cycles
ALL THE EMERGENCY LIGHTS ON ALL OF THE SEATS IN THE BACK HALF OF BUSINESS CLASS IS OUT. REPLACED BATTERY M33098 ABOVE DOOR 2R, LIGHTS ALL OPS CHECKED GOOD NOW.
Part: BUSHING — SHEARED (L1 DOOR STOP) · airframe 59,205 hrs · 10,604 cycles
DOOR 1L, NR8 AFT STOP FITTING BUSHING IS SHEARED OFF. CASTING IS OK. REPLACED BUSHING AND RIG STOP.
Part: APU — SHUTDOWN (APU BAY) · airframe 59,025 hrs · 10,576 cycles
APU SHUTDOWN WITH FAULT LIGHT, FLIGHT DIVERTED. REPLACED APU, OP'S CHECKED OK, NO LEAKS NOTED.
2010
Part: CONTROLLER — FAULTY (POSITION 2) · airframe 57,632 hrs · 10,378 cycles
"OPIC RA1" STATUS MSG ON EICAS. REPLACED RT OPBC, NO HELP. SWAPPED IN NEW OPIC CARD IN RA1 POSITION, NO HELP, RA2 POSITION, NO HELP. REINSTALLED ORIGINALS. SUSPECT RT OPIC CHASSIS M23217. REPLACED R OPCF M23217 IAW MM, NO HELP. TRIED KNOWN GOOD ENG ANTI ICE P5 PNL M33413 MESSAGE CLEARED AND OPIC TEST PASSED. REINSTALLED OLD PNL. REPLACED RT EAI SWITCH, ACCOMP MAT TEST IAW MM.
Part: INDICATOR — FAULTY (RUDDER TRIM) · airframe 56,589 hrs · 10,217 cycles
RUDDER TRIM INDICATOR SHOWS DOUBLE POINTER LEFT OF CENTER. REPLACED RUDDER TRIM INDICATOR AND OPS TESTED OKAY.
Part: BLOCKER DOOR — DAMAGED (NR 2 ENGINE) · airframe 56,344 hrs · 10,180 cycles
NR 2 ENGINE INBOARD REVERSER HALF HAS DAMAGE. FOUND EVIDENCE OF BIRDSTRIKE AT NR 2 ENG & CORE AREA. ACCOMPLISHED INSP & BORESCOPE. NO DISTRESS NOTED. REMOVED BORO PLUGS & DRIVE PAD COVER FOR INSP. ACCOMPLISHED IDLE LEAK CHECK OF NR 2 ENG GEARBOX CRANK PAD, NO LEAKS NOTED. NR 2 ENG AT 3 O'CLOCK AREA, FAN CASE EXIT LINER MISSING. NO DAMAGE FOUND. REPAIRED DAMAGE AT 9 O'CLOCK AREA. NR 2 ENG INBOARD REVERSER HALF, 2 O'CLOCK AREA MISSING LINER. NO DAMAGE FOUND. REPAIRED DAMAGE AT 10 O'CLOCK AREA. NR 2 ENG REVERSER DEACTIVATED FOR BORO. REACTIVATED NR 2 ENG REVERSER. FOUND AT 10 O'CLOCK AREA BLOCKER DOOR CRACKED. AT 11 O'CLOCK AREA REV. BLOCKER DOOR INNER LINING MISSING. REPLACED CRACKED BLOCKER DOOR.
Part: MODULE — LOW PRESSURE (HYD SYSTEM) · airframe 56,279 hrs · 10,169 cycles
HYD PRESS SYS C LOW CENTER HYD SYS PRESSURE. SYS PRESSURE LESS THAN 1200 PSI. CAUTION MSG01- ACTIVE APPROACH HARD; RESERVOIR (CTR) FLUID QUANTITY IS LOW. DB- HYD INTERFACE MODULE (HYDIM)(CL) MSG-2910150 ACTIVE AP HARD. REFILLED CTR SYS HYD RESERVOIR TO FULL. REPLACED CEN SYS ACMP PRESSURE & CASE DRAIN FILTER MODULES AND CTR SYS ADP PRESSURE AND CASE DRAIN FILTER MODULE. ALL CHECKS OK.
Part: HOSE — DAMAGED (HYD SYS) · airframe 56,279 hrs · 10,169 cycles
CTR SYS HYD FAILURE. ACCOMPLISHED INTERIM REPAIR WITH FLEX HOSE. HOSE ASSY NEEDS TO BE REPLACED AT FIRST MAINT OPPORTUNITY. REFILLED CENTER SYS HYD RESERVOIR TO FULL. REPLACED CEN SYS ACMP PRESSURE AND CASE DRAIN FILTER MODULES AND CEN SYS ADP PRESSURE AND CASE DRAIN FILTER MODULE. REPLACED FLEX HOSE WITH HOSE ASSY. PRESSURE CHECKED, NO LEAKS FOUND. ALL CKS OKAY.
Part: CONTROL PANEL — FAULTY (AUTOPILOT) · airframe 55,940 hrs · 10,117 cycles
RIGHT A-T ARM SWITCH HAS FALLEN OFF. PANEL OUT OF TOLERANCE. R & R MODE CONTROL PANEL. OPS GOOD.
Part: THERMAL BYPASS — FAULTY (APU BAY) · airframe 55,902 hrs · 10,110 cycles
APU AUTO SHUTDOWN. MAT SHOWS 49-10260, HIGH OIL TEMP. RE-STARTED WITH SAME RESULTS. REPLACED OIL FILTER, CHANGED OIL IN APU. CHECKED CHIP DETECTORS. LEAK CHECKED OKAY. RAN APU FOR AN HOUR, NO PROBLEMS FOUND, GROUND CHECK NORMAL. PERFORMED PER MM, PROBLEM STILL EXISTS. REOPENED BY OPBLM. APU OIL INDICATION INOP. PLEASE CHECK AIR INLET PATH FOR BLOCKAGE & AIR-OIL COOLER. IF OK, REPLACE THERMAL BYPASS VALVE. INCLD FNDG'S IN ACP W-U. MCD COVERED WITH METAL. REPLACED APU IAW MM. OPS CKS OK.
Part: OVEN — DIRTY (GALLEY) · airframe 55,868 hrs · 10,106 cycles
OVEN - SMOKING OR SPARKING DR-2 FWD GAL 420. CREW COMMENTS: OVENS R31 AND R32 SMOKING, STOPPED WHEN TURNED OFF. *S/D* CLEANED BURNT FOOD WRAPPING FROM VENT SCREENS, RAN FOR 10 MINUTES, NO BURNING SMELL. OVENS OP NORMAL.
Part: HEATER — FAULTY (COCKPIT WINDOW) · airframe 55,475 hrs · 10,045 cycles
WINDOW HEAT R FWD FAILURE OF RT NR 1 WINDSHIELD HEATING CIRCUIT (LOSS OF WINDOW COATING, WIRING, OR THE INDIVIDUAL WHCU CIRCUIT FOR THAT WINDOW). STATUS MSG-3021032 INACTV CL INTER 1R FWD WINDOW REPLACED. WINDSHIELD WIPER SYSTEM OPS TEST NORMAL.
Part: LAMP — BROKEN (EMERGENCY LIGHT) · airframe 55,093 hrs · 9,988 cycles
SEAT 1F EMERGENCY LIGHT BROKEN AND INOP. REPLACED LAMP ASSEMBLY. OPERATES NORMALLY.
Part: LAMP — BROKEN (EMERGENCY LIGHT) · airframe 55,093 hrs · 9,988 cycles
SEAT 34G EMERGENCY LIGHT BROKEN. REPLACED LAMP ASSEMBLY. OPERATES NORMALLY.
Part: SOCKET — BURNED (CABIN LIGHTS) · airframe 54,908 hrs · 9,959 cycles
LAV RT SIDE ABEAM ROW 26 FLOURESCENT LIGHT BALLAST HOT ELECT ODOR DISCOLORED. BALLAST OK, LT LAMP HOLDER IS BURNED UP. REMOVED LAMP AND DISCONNECTED BALLAST. NEED PCN 585-1247 2EA. RT LAMP HOLDER RELEASE IS BROKEN ALSO. IF NO LAMP HOLDERS AVAIL, BASE ASSY PN IS 0FL1100A05G02. NO PCN. REF IPC 33-26-01-004 ITEMS 125 AND 75. LAV IS USEABLE, DOME LIGHT OK.
2009
Part: MODULE — FAULTY (ALT INDICATOR) · airframe 54,599 hrs · 9,902 cycles
STDBY ALTIMETER AND STDBY AIRSPEED PROBLEM. A-S INDICATOR BLANKS OUT IN BOTH POSITIONS A-S POSITION AND ALSO IN ALTITUDE POSITION. BAD A-S INDICATOR. FLUSHED CENTER STATIC STBY. ACP WIRING CHECKS AND RINGOUTS. ACP LEFT PSA REPLACEMENT FOR STBY ATTITUDE FLUCTUATIONS. ALSO STBY AIRSPEED IND WAS SWAPPED INTO ALTITUDE POSITION AND THE BLANKING FOLLOWED. AFTER REPLACING A-S INDICATOR NO DISCREPANCIES FOUND. NO HITS AFTER FIVE LEGS.
Part: LENS — BROKEN (EMERGENCY LIGHTS) · airframe 53,878 hrs · 9,788 cycles
MID GALLEY, CENTER CEILING PANEL EMERGENCY LIGHT LENS ASSY FOUND BROKEN, TAPED IN PLACE, NOT DOCUMENTED. SECURED LENS IN PLACE WITH TAPE, LENS AND LIGHT ARE SECURED, LIGHT NOT OBSTRUCTED.
Part: BATTERY — FAILED (FLT CONTROLS) · airframe 53,818 hrs · 9,780 cycles
ON ARRIVAL EICAS STS MSG - FLIGHT CONTROL SYS - DISPLAYED. ON MAT FOLLOWING MAINT MSG SHOWN. 1) 24-50242, FC BATTERY-R- VOLT LOW, 2) 27-10510,SPOILER PCU -11- & 27-10503 SPOILER PCU-4-DOES NOT FOLLOW COMMAND. UNABLE TO GET PROBLEM SOLVED THRU MAT TESTER A-C POWER DOWN. REPLACED FLIGHT CONTROL LEAD ACID BATTERY -R. ALL TEST PASSED & ALL MSG'S CLEARED.
Part: SEAL — LEAKING (JETTISON PUMP) · airframe 53,610 hrs · 9,747 cycles
FUEL LEAK ON LT FUEL JETTISON PUMP. REPLACED LT JETTISON PUMP SEALS. NO LEAKS NOTED. ACFT OK FOR SERVICE.
Part: PRESSURE SWITCH — FAILED (LT ENGINE) · airframe 53,557 hrs · 9,739 cycles
ENG OIL FILTER SENSOR L THE PRESSURE SWITCH FOR DETECTING IMPENDING OIL FILTER BYPASS ON THE LEFT ENGINE HAS FAILED. MAT SHOWS NOT ACTIVE FOR MAINT MSG 79-60861. ACP INITIAL EVALUATION. MAT DOES NOT SHOW MSG ON EXIST FAULT SCREEN. ACP FIM 79-98-803-ERASED STS MSG. INFO TO SAMC. IN VIEW OF ACTIONS ALREADY TAKEN PREVIOUSLY APPLIED MEL7935B AND COMPLIED WITH. LEAK CHECK SATISFACTORY AFTER ENG RUN. DUE TO HISTORY, REPLACED OIL FILTER DIFFERENTIAL PRESS SWITCH. NO FURTHER ISSUES NOTED.
Part: BATTERY — FAULTY (MAIN) · airframe 52,965 hrs · 9,651 cycles
STATUS MSG MAIN BATTERY AND BATTERY CHARGER MAIN. REPLACED MAIN BATTERY AND CHARGER.
Part: LENS — MISSING (EMERGENCY LIGHT) · airframe 52,881 hrs · 9,640 cycles
DOOR 2L EMERGENCY EXIT SIGN MISSING LENS COVER, REPLACED. EMERGENCY EXIT LIGHT OPS CHK CARRIED OUT SATISFACTORY.
Part: FMU — FAULTY (NR 2 ENGINE) · airframe 52,514 hrs · 9,574 cycles
DURING START OF NR 2 ENG IN AUTO START, START SWITCH CUT OUT AT 42 PERCENT ENG CONTINUED TO CLIMB AND THEN AUTO SHUT DOWN, TRIED A SECOND TIME IN AUTO START AND EGT CLIMBED TO 510 AND ENG SHUT DOWN AGAIN. SHUT AUTO START OFF AND STARTED ENG AGAIN AND ENG STARTED WITH EGT AT 567, NR 1 ENG EGT 436. REPLACED FUEL METERING UNIT. RAN ENG AND FOUND OKAY.
Part: EXCITER — FAILED (LT ENG) · airframe 52,330 hrs · 9,549 cycles
ENG IGNITER L1 LEFT ENGINE FAILED TO IGNITE USING IGNITER 1. REPLACED IGNITION LEAD, IGNITION PLUG & EXCITER BOX, OP TEST OKAY.
Part: IDG — LEAKING (NR 2 ENGINE) · airframe 52,310 hrs · 9,545 cycles
NR 2 ENG IDG LEAKING OIL AT TERMINAL BLOCK. REPLACED NR 2 ENGINE IDG. RAN ENG OP'S AND LEAK CHECK WERE GOOD.
Part: IDG — UNDERSERVICED (RIGHT) · airframe 52,253 hrs · 9,535 cycles
RIGHT GENERATOR DRIVE LIGHT ILLUMINATED, RT GEN DISCONNECTED. SERVICED RT IDG. RAN RIGHT ENGINE, TESTED RIGHT GENERATOR, TESTS NORMAL.
Part: LIGHT — INOPERATIVE (SEAT 2F) · airframe 50,272 hrs · 9,235 cycles
SEAT 2F FWD EMERGENCY LIGHT INOP. REPLACED FWD EMERGENCY LIGHT AT SEAT 2F, OP CHECKS GOOD.
Part: CONTROL UNIT — MALFUNCTIONED (COCKPIT) · airframe 50,269 hrs · 9,234 cycles
SPOILERS FAULTING. ALSO HAS PFC CHANNEL STATUS, DC PWR AND ADIRU FAULTS. INSTALL NEW PFC AND ACE CNTR, NO HELP. REINSTALLED ORIGINAL PARTS AND ACCOMPLISH PFC AND ACE TEST, ALL PASS. ACCOMPLISH CATIII CHECK ALSO PASS, NO STATUS MSG. ALSO NO FAULT ON MAT. MAINT MSG 27-13002 HAS OCCURRED EN ROUTE MULTIPLE TIMES. REPLACED CENTER ACE AND OP CHECKS GOOD.
Part: CONTROL UNIT — FAULTY (STAB ACTUATOR) · airframe 50,199 hrs · 9,224 cycles
STABILIZER MESSAGE IN "RED" ON UPPER EICAS. STABILIZER DOES NOT RESPOND TO ANY INPUTS. REPLACED ACTUATOR CONTROL ELECTRONICS "C" AND PFC "C". ACCMP'D STAB TRIM TEST TO UNLATCH FAULT. STAB TRIM MESSAGE HAS CLEARED AND STABILIZER NOW RESPONDS TO INPUTS.
Part: CONTROL UNIT — FAULTY (STABILIZER) · airframe 50,199 hrs · 9,224 cycles
STABILIZER MSG IN "RED" ON UPPER EICAS. STABILIZER DOES NOT RESPOND TO ANY INPUTS. REPLACED ACE "C" AND PFC "C". ACCMP'D STAB TRIM TEST TO UNLATCH FAULT. STAB TRIM MSG HAS CLEARED AND STABILIZER NOW RESPONDS TO INPUTS.
Part: FSEU — FAULTY (NR 2) · airframe 50,199 hrs · 9,224 cycles
FLAP-SLAT CONTROL 2 HIGH LIFT CONTROL LANE NR 2 HAS A FAULT. STATUS MSG01- ACTIVE DESCENT HARD; FSEU 2 CENTER ARINC 629 DATA IS INVALID. DB- FSEU 2 MSG-2721232 ACTIVE DC HARD. REPLACED FSEU 2. MESSAGE CLEARED. OP CHECKS GOOD.
Part: FSEU — FAULTY (NR 2) · airframe 50,199 hrs · 9,224 cycles
FLAP-SLAT CONTROL 2 HIGH LIFT CONTROL LANE NR 2 HAS A FAULT. STATUS MSG01- ACTIVE DESCENT HARD; FSEU 2 CENTER DATA IS INVALID. DB- FSEU 2 MSG-2721232 ACTIVE DC HARD. REPLACED FSEU 2. MESSAGE CLEARED. OP CHKS GOOD.
2008
Part: TUBE — CRACKED (NR 2 STARTER) · airframe 49,861 hrs · 9,177 cycles
RIGHT START VALVE WILL NOT OPEN IN AUTO START. REPLACED NR 2 START VALVE AND STARTER, NO HELP. T/S IN PROGRESS. SWAPPED ENG START MODULE, SWAPPED ENG RELAY BOX. NO HELP. NO AIR COMING OUT OF ENG START SOLENOID WITH START SWITCH ACTIVATED AND AIR ON. START VALVE TUBE CRACKED. REPLACED LINE. ENGINE START GOOD IN AUTO AND MANUAL.
Part: DUCT — WORN (APU) · airframe 49,501 hrs · 9,124 cycles
APU PRESSURE DUCT FOUND WORN BEYOND LIMITS, BY CONTACT WITH STRUCTURE CUTOUT AT STA 2360 FRAME. REMOVED DUCT, WELD REPAIRED. REINSTALLED AND LEAK CHECKED. REPLACED SUPPORT NYLON SLEEVE.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 49,308 hrs · 9,094 cycles
SEAT 24G EMERGENCY LIGHT IS OUT. RELAMPED, TESTED GOOD.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 49,308 hrs · 9,094 cycles
SEAT 1E EMERGENCY LIGHT IS OUT. REPLACED LIGHT ASSY, OP CHECKS GOOD.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 49,308 hrs · 9,094 cycles
SEAT 24G EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT, TESTED GOOD.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 49,308 hrs · 9,094 cycles
EMERGENCY LIGHTS OUT AFT GALLEY RT WALL BY FLOOR ACROSS FROM DOOR 4R, 2 AFT LIGHTS NOT WORKING. RELAMPED EMERGENCY LIGHTS, TESTED GOOD.
Part: BATTERY PACK — FAILED (R2 DOOR) · airframe 49,308 hrs · 9,094 cycles
DOOR 2R EPAS BATTERY TEST FAILED. BATTERY FAILED TEST. REPLACED BATTERY PACK. OPS CHECK GOOD.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,308 hrs · 9,094 cycles
SEAT 36G EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT, TESTED GOOD.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 49,308 hrs · 9,094 cycles
SEAT 43G EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT, TESTED GOOD.
Part: OIL COOLER — FAULTY (NR 1 ENGINE) · airframe 49,013 hrs · 9,047 cycles
L ENG OIL QTY INDICATION DROPPING INDICATED 2QTS WITH TEMP RISING. CREW REPORT. RPLD AIR COOLED OIL COOLER. RUN, OPS LEAK CK OK.
Part: OIL COOLER — MALFUNCTIONED (LT ENGINE) · airframe 49,013 hrs · 9,047 cycles
L ENG OIL QTY INDICATION DROPPING INDICATED 2 QTS WITH TEMPERATURE RISING, CREW REPORT. REPLACED AIR COOLED OIL COOLER. RUN, OPS LEAK CHECK OK.
Part: LIGHT — MISSING (SEAT 1F) · airframe 48,988 hrs · 9,041 cycles
EEL 1F MISSING 2F HANGING LOOSE. LIGHT MISSING. REPLACED EMERGENCY LIGHT AT SEAT 1F.
Part: DUCT — DAMAGED (NR 1 ENGINE) · airframe 48,988 hrs · 9,041 cycles
NR 1 ENGINE HPT DAMAGE. REPLACED NR 1 ENGINE. SHOP TEARDOWN FOUND A MISSING HP TURBINE STAGE-2 DUCT SEGMENT. ADJACENT SEGMENTS HAD FOREIGN MATERIAL LODGED IN THE INTERNAL COOLING PASSAGES THAT CHOKED OFF COOLING AIR. THIS CAUSED BOWING, WHICH LEAD TO HEAVY BLADE RUB AND EVENTUAL SEGMENT LIBERATION.
Part: TURBINE — DAMAGED (NR 1 ENGINE) · airframe 48,988 hrs · 9,041 cycles
NR 1 ENGINE HPT DAMAGE.
Part: BATTERY — WEAK · airframe 47,254 hrs · 8,758 cycles
APU ARRIVED AT GATE WITH AN APU WEAK BATTERY MESSAGE AND APU CHARGER MESSAGE. BATTERY VOLTS AT 24 VDC, CHARGER NO MORE THAN 1 AMP CHARGE. FOUND FAULTY CHARGER. REPLACED APU BATTERY CHARGER AND APU BATTERY, REF MM 24-31-06 AND MM 24-31-05. OPS TEST OK.AC OK FOR SERVICE.
Part: LIGHT — MISSING (CABIN) · airframe 47,035 hrs · 8,722 cycles
AFT EMERGENCY LIGHT MISSING FROM ARMREST AT SEAT 1F. SUPPLEMENTAL DATA UPDATE REPLACED BROKEN EEL LIGHT WITH NEW ASSY.
Part: FILTER — UNKNOWN (IDG) · airframe 43,646 hrs · 8,610 cycles
FOUND RIGHT HAND ENG IDG FILTER BYPASS D, P, I POPPED OUT. REPLACED IDG PER MM 24-11-01. OPS. CHECK NORMALLY. SUSPECT IDG BEARING & SEAL DETERIORATION. COMPLETED VERIFICATION FLT & RT ENGINE IDG CHECKD GOOD FOR SERVICE.
2007
Part: BRACKET — MISINSTALLED (R2 DOOR GIRT BAR) · airframe 45,557 hrs · 8,493 cycles
IMPROPERLY INSTALLED GIRT BAR RESULTING IN SLIDE DEPLOYMENT WHEN SLIDE LEVER IN DISARMED POSITION. FWD FLAG BRACKET BROKEN. REPLACED FLAG BRACKET SLIDE AND BOTTLE. GIRT BAR ENGAGES NORMAL. AC OK FOR SERVICE.
Part: ACTUATOR — NO TEST (FLAPERON) · airframe 45,163 hrs · 8,430 cycles
RAN RT FLAPERON POSITION TEST AND RESULT WAS FAILURE OF RT OTBD FLAPERON ACTUATOR TO ACHIEVE COMMANDED POSITION. RAN RIGHT FLAPERON POSITION TEST AND RESULT WAS FAILURE OF RH OTBD FLAPERON ACTUATOR TO ACHIEV E COMMANDED POSITION. INSTALLED NEW FLAPERON ACTUATOR AND SYSTEM CHECKED OK FOR SERVICE. SUSPECT STICKING DUE TO DEBRIS BUILDUP.
Part: LIGHT — INOPERATIVE (SEAT 1F) · airframe 45,110 hrs · 8,422 cycles
AFT EEL LIGHT AT SEAT 1F INOP. REPLACED LIGHT ASSY AT SEAT 1F AFT.
Part: BATTERY — FAILED (APU) · airframe 44,657 hrs · 8,350 cycles
APU BATTERY FAILURE. 10-26-07 REPLACED APU BATTERY & APU BATTERY CHARGER, SYSTEM OP CHECKS GOOD.
Part: CIRCUIT CARD — FAULTY (FIRE DETECTION) · airframe 43,590 hrs · 8,181 cycles
FIRE LOOP 2 ENG R STATUS MESSAGE. REPLACED CIRCUIT CARD.
Part: OXYGEN BOTTLE — READS LOW (CREW) · airframe 43,583 hrs · 8,180 cycles
CREW O2 LOW 300 PSI. [08-08-07] REMOVED AND REPLACED CREW O2 BOTTLE, LEAK CHK OK. AIRCRAFT RETURNED TO SERVICE.
Part: STRINGER — DAMAGED (BS 793 S33R) · airframe 43,583 hrs · 8,180 cycles
DAMAGE REPORTED BY CATERING TRUCK ADJACENT TO R2 DOOR. DAMAGE IS AT STA 793, ON STRINGER S-33R. [08-08-07] DOUBLER INSTALLED & INSPECTED. AIRCRAFT OK FOR SERVICE. DAMAGE CAUSED BY CONTACT WITH CATERING TRUCK.
Part: NONE — NONE (NONE) · airframe 43,469 hrs · 8,163 cycles
FLIGHT DIVERTED DUE TO REPORT OF FUMES IN THE CABIN ISOLATED TO THE NR 2 ENGINE. [07-17-07] CHECKED APU INLET & FOUND INTAKE SCREEN FULL OF CICADAS. SUSPECT ALL SMOKE AND ODOR RELATED LOG ITEMS CAUSED BY CICADAS WHICH WERE BURNED BY LOAD COMPRESSOR OF APU. REPLACED APU DUE TO POSSIBLE FOREIGN OBJECT INGESTION.
Part: LIGHT — BROKEN (SEAT 34C) · airframe 42,681 hrs · 8,032 cycles
FOUND EEL LIGHT AT 34C BROKEN. REPLACED EEL LIGHT AT 34C. OP CHECKS GOOD.
Part: PACKING — LEAKING (HYD PUMP) · airframe 42,451 hrs · 7,995 cycles
POSSIBLE CENTER HYDRAULIC LEAK. NO EMERGENCY DECLARED. *S/D* FOUND C2 ELECTRIC PRESSURE OUTPUT PACKING LEAKING. REPLACED PACKING NO LEAKS NOTED. HYDRAULIC QTY LOW C CENTER HYDRAULIC SYSTEM LOW RESERVOIR QUANTITY. SERVICED CENTER HYD SYSTEM TO FULL. MSG CLEARED. A/C CLEARED FOR SERVICE.
Part: SKIN — DAMAGED (RT NLG DOOR) · airframe 42,257 hrs · 7,965 cycles
LIGHTNING STRIKE DAMAGE TO RIGHT NLG DOOR. REPAIRED LIGHTNING STRIKES REF SRM 52-80-01. REPAIR TAP CKS GOOD. A/C OK FOR SERVICE.
Part: FAN — SMOKE (CABIN) · airframe 42,092 hrs · 7,934 cycles
CREW REPORTED SMOKE IN THE CABIN AROUND DOORS 2 LT & RT WITH ELECTRICAL ODOR. RAN PACKS, GALLEY CHILLERS, COFFEE MAKERS AND OVENS IN BUSINESS CLASS GALLEY. NO DEFECTS FOUND. IDENTIFIED LOWER LT RECIRCULATION FAN FAILURE AS CAUSE OF STRONG ELECTRICAL ODOR AND SMOKE. FAN REPLACED. SYSTEM OP CHECKED OK.
2006
Part: O-RING — LEAKING (SLIDE BOTTLE) · airframe 42,842 hrs · 6,490 cycles
LOW BOTTLE PRESSURE GAUGE O-RING AND PACKING BACK LEAKING. REPLACED O-RING AND PACK IN BACKING.
Part: WARNING SYSTEM — ACTIVATED (COCKPIT) · airframe 39,998 hrs · 7,552 cycles
EQUIPMENT COOLING EICAS STATUS MESSAGE DISPLAYED WITH ASSOCIATED WARNING HORN. REPLACED VSCF FAN. NO HELP. REPLACED VSCF DUCT PRESS SENSOR M21585. SYSTEM CHKS NORMAL
Part: LIGHT — INOPERATIVE (CABIN) · airframe 38,593 hrs · 7,294 cycles
EMERGENCY LT INOP AT SEAT 25C. RELAMPED, TESTED GOOD.
Part: LAMP — INOPERATIVE (SEAT 11D) · airframe 37,734 hrs · 7,152 cycles
AFT EMERGENCY PROX EEL LIGHT AT SEAT 11D IS INOP.
2005
Part: LIGHT — INOPERATIVE (CABIN) · airframe 37,281 hrs · 7,082 cycles
SEAT 2E BOTH EMERGENCY LIGHTS INOP. RELAMPED BOTH EMERGENCY LIGHTS. OP CHECKS GOOD.
Part: LIGHT — LOOSE (CABIN) · airframe 36,886 hrs · 7,016 cycles
AFT EEL LIGHT 1F RIPPED FROM POS. REPLACED EEL LIGHT.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 36,886 hrs · 7,016 cycles
AFT EEL LIGHT 2E INOP. REPLACED EEL LIGHT.
2004
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 32,266 hrs · 6,204 cycles
09MAY OAK CF -9 :FWD PIT FLOORBEAM UPPER AFT FLANGE CRACKED IN RADIUS APPROX BS 15 RBL 29. REPAIR INSTALLED PER 53-00-53, (INTERIM REPAIR) AND MUST BE REPLACED WITH A CAT-A OR CAT-B BEFORE 4000 FLIGHT CYCLES. MAJOR REPAIR ACCOMPLISHED. PERMANENT REPAIR ACCOMPLISHED THIS VISIT.
2003
Part: TRANSDUCER — DEFECTIVE (CREW O2) · airframe 29,843 hrs · 5,751 cycles
LOST ALL CREW OXYGEN. DEFECTIVE O2 TRANSDUCER. REPLACED TRANSDUCER.
Part: CONTROL UNIT — FAILED (SEAT SEU) · airframe 29,741 hrs · 5,732 cycles
SMOKE AND ODOR REPORTED IN CABIN. F/A DISCONNECTED SEVERAL WIRES UNDER 19C AND 18C, CREW REPORTED GALLEY POWER AND SEAT POWER TURNED OFF PRECAUTIONARY, SMOKE AND ODOR DISSAPATED. SEAT ELECTRONIC UNIT AT SEAT 18D FAILED. UNIT WAS REPLACED. SYSTEM OP NORMAL. UNIT WAS OPENED IN SHOP AND CAPACITOR WAS FOUND BURNED.
Part: CIRCUIT BOARD — FAILED (SEAT 13F VDU) · airframe 29,662 hrs · 5,719 cycles
SMOKE COMING OUT OF SEAT ELECTRONIC UNIT. DISCONNECTED WIRES TO UNIT AND POWER SWITCHED OFF TO ENTERTAINMENT SYS AND LAPTOP POWER. THE VIDEO DISTRIBUTION BOX AT SEAT 13F FAILED. THE UNIT WAS REPLACED AND ENTERTAINMENT SYSTEM OP CHECKED OKAY. THE UNIT WAS EXAMINED IN COMPONENT SHOP AND FOUND CHIP FAILURE ON THE MAIN CIRCUIT BOARD.
Part: LINE — CONTAMINATED (EEC) · airframe 29,660 hrs · 5,718 cycles
ON CLIMB TO FL410 FROM FL370 ENGINES MAXED OUT. PWR REQ 1.47 LEFT ENG TOPPED OUT. RIGHT 1.430 WITH RT THROTTLE AT STOP AND LT ENG THROTTLE ABOUT 1 & 1 AND A HALF INCHES BEHIND. THRUST SHORT FALL WAS CAUSED BY AN AMBIENT PRESSURE (PAMB) SENSOR ERROR TO THE EEC. THE ERROR WAS DETERMINED NOT TO BE INTERNAL TO THE EEC UNIT ITSELF. REMOVED EEC WAS TESTED BY HAMILTON-SUNDSTRAND, AND PASSED ALL INCOMING FUNCTIONAL CHECKS. A LOOSE PAMB B-NUT WAS TIGHTENED ON 12/17/03. ON 12/18/03, WHEN THE EEC WAS REPLACED, APPROXIMATELY A TEASPOON OF WATER WAS DRAINED OUT OF THE PAMB LINE. IT IS BELIEVED THAT THE COMBINATION OF THE LOOSE NUT, ALONG WITH WATER CONTAMINATION, CAUSED THE PAMB ERROR.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 28,969 hrs · 5,588 cycles
AFT GALLEY EEL LIGHT RIGHT SIDE AT FLOOR INOP. REPLACED LIGHT ASSEMBLY.
2002
Part: SKIN — CRACKED (PAX DOOR) · airframe 23,182 hrs · 4,495 cycles
NR 4L PASSENGER DOOR EXTERIOR SKIN DENTED AT EDGE AT LOWER AFT CORNER OUT OF LIMITS. MAJOR REPAIR ACCOMPLISHED. ROUTED OUT CRACK AND INSTALLED REPAIR DOUBLER.
Part: ENGINE — MALFUNCTIONED (NR 1) · airframe 22,626 hrs · 4,391 cycles
ENG TORCHING ON START DURING GROUND MAINT TEST RUN. SEVERAL COMPOSITE PANELS LT WING T/E BOTTOM OF WING JUST AFT AND TO BOTH SIDES ON NR 1 ENG HAVE HEAT DAMAGE. FUEL METERING UNIT (FMU) WAS REPLACED, COULD NOT FIND FAULT WITH UNIT. FMU PASSED AS-RECEIVED TEST. NOTHING UNUSUAL WAS FOUND, ALL PARTS AND ALL PACKINGS/RINGS WERE IN GOOD CONDITION WITH LITTLE OR NO WEAR. THE SEALING SURFACES OF THE FMU MPSOV AND ITS MATING SURFACE IN THE HOUSING HAD NO SIGNS OF DAMAGE OR EXCESSIVE WEAR. THE CAUSE OF TORCHING IS UNKNOWN.
2001
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 19,318 hrs · 3,766 cycles
DISCREPANCIES: STA. 246 BUCKLED STIFFENER AT LBL - 7, RBL - 26.06, 50.0STA. 246 CRACKED STIFFENER AT LBL - 38.5STA. 246 CRACKED MID-CHORD AT LBL - 7 REPAIRED MID-CHORD PER SRM 53-10-51, REPAIR 2.REPLACED CRACKED AND BUCKLED STIFFENERS PER SRM 53-10-51, REPAIR 3.
2000
Part: EEC — INADEQUATE (RT ENGINE)
RT ENG ON TAKEOFF LOST .03-.09% AT ABOUT 70 KNOTS. NOTICED RT THROTTLE MOVE TO FULL FORWARD. POWER CAME BACK ABOUT TIME PACKS RESTORED. S/D* ACPL HIGH PWR ACCEL-DECEL & AUTO THROTTLE TESTS, NO DISCREPANCIES FOUND. RT ELECTRONIC ENG CONTROL SET MAX EPR LIMIT TOO LOW DURING PACKS-OFF T/O. EEC SOFTWARE COMPUTATION ERROR CAN OCCUR WHEN 30-SECOND AIR -CONDITIONING PACK BLEEDDOWN PERIOD ENDS W/IN 200 MILLISECONDS OF MOMENT EEC SENSES ITS 65 KNOT RATING LOCKUP AIRSPEED FOR T/O. RECOVERY IS AUTOMATIC AT START OF CLIMB. FLT MANUAL PROC FOR PACKS-OFF T/O WAS REVISED TO INITIATE PACK SWITCH-OFF AT LEAST 30 SECONDS PRIOR TO START OF T/O ROLL.
1999
Part: O-RING — CUT (APU)
TWENTY MINUTES AFTER DEPARTURE, AIRCRAFT EXPERIENCED SMOKE IN COCKPIT AND CABIN. RT AIR CONDITIONING PACK WAS SHUT DOWN AND SMOKE SUBSIDED. AIRCRAFT RETURNED TO EWR. *S/D* APU (P/N 3800550-1), (S/N P1054), THE LOAD COMPRESSOR DISASSEMBLY YIELDED THE FOLLOWING RESULTS: BEARING HOUSING HAD EVIDENCE OF OIL STREAKING FROM THE PARTING SURFACE TO THE AIR INLET. BEARING HOUSING O-RING (M8324-1-158) WAS ROLLED AND HAD A SECTION CUT (SLICED) FROM THE OD APPROX .25 INCH LONG. BEARING CARRIER O-RING (M8324-1-145) CUT (SLICED) IN 3 DIFFERENT SECTIONS FOR A TOTAL OF 3 INCHES OF O-RING MATERIAL REMOVED.
1997
Part: CONTACTOR — FAILED (APU)
APU SHUT DOWN AT GATE. AIRCRAFT WILL NOT ACCEPT APU POWER. INVESTIGATION REVEALS CONTACTOR (START RELAY) FAILED (WOULD NOT CLOSE). REPLACED PN BP493-1. OPERATIONAL CHECK OK.
1996
Part: ENGINE — OIL LOSS (LEFT)
LEFT ENGINE OIL QUANTITY TO ZERO, OIL PRESSURE TO ZERO AND ENGINE SHUTDOWN. RETURN TO FIELD.