Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
183 reports on file, 1998-03-26 – 2026-10-28.
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 119,812 hrs · 15,563 cycles
DURING A POWER SUPPLY BATTERY PACK CAPACITY CHECK, FOUND BATTERY LOW ABOVE R1 DOOR. REPLACED THE POWER SUPPLY PACK AND PERFORMED INSTALLATION TEST WAS NORMAL IAW AMM 33-51-06-960-802, REV 108.
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 119,812 hrs · 15,563 cycles
DURING A POWER SUPPLY BATTERY PACK CAPACITY CHECK, FOUND BATTERY LOW ABOVE R4 DOOR, POWER SUPPLY (M33408). REPLACED THE POWER SUPPLY BATTERY PACK ABOVE THE R4 DOOR(M33408) AND PERFORMED INSTALLATION TEST, FOUND NORMAL IAW AMM 33-51-06-960-802, REV 108.
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 119,812 hrs · 15,563 cycles
DURING A POWER SUPPLY, BATTERY PACK CAPACITY CHECK. FOUND THE BATTERY PACK LOW ABOVE THE L4 DOOR. POWER SUPPLY (M33407). REPLACED THE POWER SUPPLY BATTERY PACK AND PERFORMED AN INSTALLATION TEST, FOUND NORMAL IAW AMM 33-51-06-960-802, REV 108.
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 119,812 hrs · 15,563 cycles
DURING A POWER SUPPLY BATTERY PACK CAPACITY CHECK, FOUND THE BATTERY PACK LOW ABOVE L2 DOOR. POWER SUPPLY (M33096). REPLACED THE POWER SUPPLY BATTERY PACK AND PERFORMED AN INSTALLATION TEST, FOUND NORMAL IAW AMM 33-51-06-960-802, REV 108.
Earlier reports · 1998–2025 · 179 reports
2025
Part: SWITCH — FAULTED (ZONE 800) · airframe 114,800 hrs · 15,007 cycles
DOOR BULK CARGO EICAS ADVISORY BULK CARGO DOOR NOT FULLY CLOSED, LATCHED AND LOCKED. REFERENCE PREVIOUS HISTORY REQUEST MEL 5271F. MEL REQUESTED DUE TO INDICATION HISTORY, DOOR TO BE VERIFIED CLOSED BEFORE EACH FLIGHT TOMC APPROVES MEL 5271F COMPLIED WITH MEL 5271F *DM* DUE TO BULK CARGO IND FAULTS DURING DESCENT BUILDING HISTORY WITH NO PARTS RPLCD - RECOMMEND TO R+R SWITCH S52020 - ALSO RECOMMEND TO ENSURE THE SWITCH AND ASSOSCIATED WIRING HAS A GOOD GRND AND THE WIRE IS NOT DAMAGED. SWTCH S52020 ALREADY ON M+L IF NEEDED REMOVED AND REPLACED BULK CARGO DOOR SWITCH, OPS CHECK GOOD REF AMM 52-71-04-900-80.
Part: FILTER — MISSING (ZONE 200) · airframe 114,671 hrs · 14,994 cycles
FLIGHT ATTENDANT CREW REST FILTER NEEDS REPLACING FA CREW REST COMPARTMENT DOESNT HAVE FILTER. CHECKED WITH APU ON AND PACKS ON - NO SMELL, FUMES ETC. PLEASE REPORT FURTHER
Part: TRANSDUCER — FAULTED (ZONE 100) · airframe 114,074 hrs · 14,927 cycles
CREW OXYGEN DROPPED FROM 1480 TO 90 FOUND CREW O2 BOTTLE WITHIN SERVICE LIMITS. REMOVED AND REPLACED CREW O2 PRESSURE TRANSDUCER IAW AMM 35-11-03. OPS CHECK NORMAL. NO LEAKS NOTED. CREW O2 READS 1650.
Part: GIRT BAR — MALFUNCTIONED (ZONE 800) · airframe 113,890 hrs · 14,906 cycles
DOOR 4R GIRT BAR SHOWS STIP OF YELLOW ON RIGHT SIDE WHEN DISARMED, COULD NOT DUPLICATE FAULT. PERFORMED OPS CHECK MULTIPLE TIMES OF DOOR 4R SLIDE ARM/DISARM FLOOR LEVEL VISUAL INDICATION. WHEN SLIDE IS ARMED, YELLOW STRIPE IS VISIBLE. WHEN DISARMED, YELLOW STRIPE IS NOT VISIBLE. OPS CHECK GOOD. A/C O.K. FOR CONTINUED SERVICE.
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 113,114 hrs · 14,821 cycles
M/D R1 DOOR M33094 EMERGENCY LIGHT POWER SUPPLY BATTERY PACK FOU ND OUT OF LIMIT DURING DEEP CYCLE TEST. REPLACED M/G R1 DR M3309 4 EMERGENCY LIGHT POWER SUPPLY BATTERY PACK AND DO A TEST OF THE NEW BATTERY PACK FOR CAPACITY CHECK, THE TEST RESULT NORMAL, PER AMM 33-51-06-960-801 & 33-51-06-200-801 REV 103.
Part: BATTERY — NO TEST (ZONE 200) · airframe 113,114 hrs · 14,821 cycles
M/D R1 DOOR M33094 EMERGENCY LIGHT POWER SUPPLY BATTERY PACK FOU ND OUT OF LIMIT DURING DEEP CYCLE TEST - BATTERY FAILED TEST DOOR 1R. REPLACED M/D R1 DOOR M33 094 EMERGENCY LIGHT POWER SUPPLY BATTERY PACK AND DO A TEST OF T HE NEW BATTERY PACK FOR CAPACITY CHECK, THE RESULT NORMAL AS PER AMM 33-51-06-960-801 & 33-51-06-200-801 REV 103.
Part: SLIDE — NOT REPORTED (ZONE 800) · airframe 112,940 hrs · 14,803 cycles
REMOVED DOOR 1L EMERGENCY SLIDE SN 0801. REFERENCE MM 25-66-01. REPLACEMENT SLIDE REJECTED BY INSPECTION. REF TASK CARD 26-2566-9-0007 FOR WORK ACP'D
2024
Part: WARNING MESSAGE — ILLUMINATED (L1 DOOR LOCK) · airframe 111,523 hrs · 14,643 cycles
DOOR FLIGHT LOCK 1L EICAS STATUS #1 LEFT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SENS OR DISAGREEMENT.DB PSEU 2 (R2) DB PSEU 2 (L2) ITEM DUO WITH LP9918819
Part: LOOP — WARNING MESSAGE (NR 2) · airframe 109,347 hrs · 14,400 cycles
BLEED LOOP 2 BODY STATUS MSG. NEED TO DEFERR BLEED LOOP 2 BODY AS PER MEL 2618F. DEFERRED BLEED LOOP 2 BODY AS PER MEL 2618F. MEL PROCEDURE COMPLETED. PLACARD INSTALLED. TOMC APPROVES THE USE OF MEL 2618F *DM* REF. FIM 26-18 TASK 803 FOR TROUBLESHOOTING. *DM* MX NOTE, PLACING A DLODS CARD 27-2612-9-0001.
Part: CONTROL VALVE — FAILED (RT A/C PACK) · airframe 107,570 hrs · 14,189 cycles
RT PACK FAILED IN FLIGHT. AT TOMC REQUEST BOTH UPPER AND LOWER R/H PACK FLOW CONTROL VALVES REPLACED, IAW AMM 21-51-01 AND 21-51-02 REV 99. LOG UPDATED FOR ROTABLE PARTS CHANGE. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1404926 SN OFF 0022 TT # 1226861 SN OFF 3410. VALVE, AIR, PAC OFF 25-2151-9-0002 8822 ON 0000 VALVE, AIR, PAC OFF 25-2151-9-0002 8822 ON 25-2151-9-0002 8035 VALVE, AIR, PAC OFF 25-2151-9-0002 0341 ON 0000 VALVE, AIR, PAC OFF 25-2151-9-0002 0341 ON 25-2151-9-0002 3292. OP AND LEAK CHECK C/OUT SATIS.
2023
Part: FITTING — CRACKED (LH ELEVATOR) · airframe 107,385 hrs · 14,166 cycles
SUPPORT TASK LH ELEVATOR O/B ACTUATOR FITTING 1EA CRACK FOUND PRINT ANDACCOMPLISH EA 5510-01896 OP.009 FOR RMOVE AND REPLACE CRACKED FTG , TRANSFER TO WO.2523994 AND ORIGINATED BY V924735 LH ELEVATOR O/B ACTUATOR FITTING REPLACED AS PER EA5510-01896 REC C OP 009 WORK ACCOMPLISHED BY MECHANIC V920500 INSPECTED BY V898553 RII INSPECTED BY HX146606 ADD EMP:V896834
Part: FAN — BROKEN (STA 993) · airframe 106,718 hrs · 14,073 cycles
PER FLIGHT CREW, FLIGHT ATTENDANTS REPORTS ODOR IN THE CABIN ON CLIMB AFTER TAKE OFF. DISSIPATED AT CRUISE. FLIGHT ATTENDANT FEL T ILL. CREW ELECTED TO RETURN TO FIELD. ODOR SEEMED TO RETURN A N D GET STRONGER ON DECENT. SEVERAL ATTENDANTS AND PASSENGERS RE PO RTED FEELING ILL. NO SMOKE. ODOR SMELLED A LITTLE LIKE PLASTI C, IRRITATING TO EYES. MOSTLY IN BACK OF AIRCRAFT, NOTHING IN FL IGH T DECK. PILOTS COULD NOT DETECT ANY ODOR. CREW REPORTED TO MX APU WAS TURNED OFF ON TAXI AND NOT USED DURING FLIGHT. FOUND LOWER RECIRCULATION FAN BROKEN (FAN BLADES BROKEN) NEEDS TO BE REPLACED. LOCATED ALL BROKEN-OFF BLADE PARTS AND REMOVED. REMOVED OLD RECIRCULATION FAN ASSY REF AMM TASK 21-25-07-000-801 (REMOVED ALL BROKEN OFF BLADE PARTS FROM THE SYSTEM) AND INSPECTED REF AMM TASK 21-25-07-200-801. A NEW RECIRCULATION FAN ASSY IS REQUIRED. PLEASE SEE IPC 21-25-07-02 ITEM 25 (P/N FLAGGED SDR 4100943B) FOR PART IDENTIFICATION. INFO FAN, LAV/GALLEY OFF 27-2126-9-0002 0460 ON 27-2126-9-0002 1389 FAN, LAV/GALLEY OFF 27-2126-9-0002 0460 ON 0000 INSTALLED LOWER RECIRCULATION FAN REF AMM TASK 21-25-07-400-801. OPS CHECK GOOD. OK FOR FURTHER SERVICE. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1681174 SN OFF 0460 IPC REFERENCE # 21-25-07-02 ITEM 25.
2022
Part: PANEL — MISSING (NR 1 NACELLE) · airframe 102,669 hrs · 13,543 cycles
PDA 3 #1 ENGINE PYLON DOOR 433CL MISSING. INSTALLED LEFT PYLON LEFT SIDE ACCESS PANEL 433CL. AERODYNAMIC SMOOTHNESS AND FIT AND FINISH FOUND SATISFACTORY.
Part: STRUT — MISSING (433CL) · airframe 102,263 hrs · 13,488 cycles
PDA 2 REF TO LP 9171005(PYLON LEFT ACCESS DOOR LEFT STRUT 433CL MISSING ON ARRIVAL ) ACCOMPLISH VISUAL INSPECTION ON AIRCRAFT FOR ANY DAMAGES...TOMC MO VISUAL INSPECTION ACCOMPLISHED, NO ABNORMALITIES NOTICED.
Part: BATTERY PACK — LOW (M33408) · airframe 101,589 hrs · 13,383 cycles
DR 4R EMERGENCY LIGHT POWER PACK M33408 LOW VOLTAGE,REFER HAECO NON-ROUTINE LP:9478580,ORIGINATED BY EMP V905389,SPEC NO.B777-33 -3-7019. PERFORMED BY EMP V905389,REPLACED DR 4R M33408 EMERGENCY LIGHT B ATTERY PACK AND PERFORMED TEST OF THE NEW BATTERY PACK AS PER AM M 33-51-06-960-802 REV 94 TEST RESULT NORMAL. IDT BY EMP V905389 .
Part: BATTERY — INOPERATIVE (R4 DOOR) · airframe 101,570 hrs · 13,380 cycles
EMERGENCY LIGHT BATTERY PACK INOP LOCATED BEHIND ACCESS PANEL ABOVE DOOR R4 REMOVED EMERGENCY LIGHT BATTERY PACK P/N AD-D717-01-1 S/N 110580, AND REPLACED WITH S/N 229798 LOCATED BEHIND ACCESS PANEL ABOVE DOOR R4 REF 777-200 AMM 33-51-06 REV 93 OPPS CHECK GOOD
Part: BATTERY — INOPERATIVE (2L DOOR) · airframe 101,570 hrs · 13,380 cycles
EMERGENCY LIGHT BATTERY PACK INOP LOCATED BEHIND ACCESS PANEL ABOVE DOOR 2L REMOVED EMERGENCY LIGHT BATTERY PACK P/N AD-D717-01-1 S/N 72889, AND REPLACED WITH S/N 241638 LOCATED BEHIND ACCESS PANEL ABOVE DOOR 2L REF 777-200 AMM 33-51-06 REV 93 OPPS CHECK GOOD
2020
Part: SLIDE — UNSERVICEABLE (L3 DOOR) · airframe 101,556 hrs · 13,376 cycles
AFTER REMOVING SLIDE PIN B,THE SLIDE SUDDENTLY FAILLEN AND DISPERSED REF NON-ROUTINE NO.9413465 - ORIGINATED . PERFORMED TROUBLE SHOOTING PERFORMED &FND RELEASE CABLE,FALLEN OUT LED TO SLIDE DISPERSED,THE SLIDE REPLACED AS PER AMM 25-66-01-000-801,AMM 25-66-01-400-801 & AMM 25-66-01-820 -801 REV.88,THE RESULT IS ''SATIS''. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1017011 SN OFF 0259 SLIDE, B777-200 OFF 25-2560-9-0007 0259 ON 25-2560-9-0007 0561
Part: BATTERY PACK — DISCHARGED (L1 DOOR) · airframe 101,556 hrs · 13,376 cycles
M/D L1 DOOR HEADER 1EA EMER LT''S POWER PACK (M33424) FOUND LOW CAPACITY REF NON-ROUTINE NO.9413294 - ORIGINATED SPEC NO.B777-33-3-7015.
Part: DUCT — DAMAGED (CABIN AIR) · airframe 101,356 hrs · 13,343 cycles
PER VERBAL FROM CREW: UNABLE TO HEAT FLIGHT DECK.WARMEST TEMP IS 52 DEGREES WITH SELECTOR IN FULL WARM IN BOTH AUTO AND MANUAL MODE. TRIED AC RESET-NO HELP. NON FLYING FLIGHT CREW NOTICED SLIGHT NOISE/VIBRATION AT FLOOR AT ROW 9. CREW REPORTS THAT SYNOPTIC PAGE SHOWS FD TRIM AIR VALVE AT FULL (W). CHECK FD TRIM AIR DUCTING REF AMM 21-61-02. REMOVED & REPLACED DAMAGED LH AIR DUCT REF IPC 21-52-51-08 ITEM 240 M&E 27-2152-3-0028. NO LEAKS NOTED. RAN BOTH ENGINS AND PACK SYSTEM TO VERFIFY THAT COCKPIT HEATS UP NICELY.
2019
Part: SKIN — DENTED (BS 1035) · airframe 100,666 hrs · 13,270 cycles
L/H SIDE SKIN FOUND ABRASION MARK AFTER 1035 UNDERWING LONGERON REMOVAL AD 2019-11-02, EA 5310-06900 REV B OP13. BS1035 STR37L UNDERWING LONGERON F ITTITNG MODIFICATION ACCOMPLISHED PER EC/RA 5343-01051 REV -.
Part: STRUCTURE — CRACKED · airframe 100,666 hrs · 13,270 cycles
PERFORM OPEN HOLE INSP FOUND CRACK AT LH LONGERON AT FRONT SPAR LWR CHORD. REF NON-ROUTINE NO.9494730 - EA5310-06900 REV B OP13 STEP 8.6. WING CENTER SECTION L/H FRONT SPAR LOWE R CHORD REPAIRED AS PER SRM 57-10-10 REPAIR1 REV 81 AND EC/RA 57 10-02743 REV -.
2018
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
FWD BATTERY PACK M33093 CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.
Part: ANGLE — CRACKED (BS 2370 BULKHEAD) · airframe 92,644 hrs · 12,371 cycles
RIGHT PIVOT BULKHEAD FORWARD ANGLE FOUND CRACKED.
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
AFT BATTERY PACK M33405 CAPACITY CHECK FAILED. THE BATTERY AND CHARGER WERE REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.
Part: STRINGER — CRACKED (BS 2268-2293) · airframe 92,644 hrs · 12,371 cycles
LEFT FUSELAGE BETWEEN BS 2268 AND 2293, STRINGER FOUND CRACKED. REPAIRED IAW SRM 53-80-05, REPAIR 1.
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
AFT BATTERY PACK M33098 CAPACITY CHECK FAILED. THE BATTERY AND CHARGER WERE REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.
Part: CHARGER — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
L4 DOOR BATTERY M33407 CAPACITY CHECK FAILED. THE BATTERY AND CHARGER WERE REPLACED AND CAPACITY TESTED WITH NORMAL RESULTS IAW AMM 33-51-06.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
L3 DOOR MID BATTERY PACK M33406 CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND CAPACITY CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
FWD BATTERY PACK M33408 CAPACITY CHECK FAILED. THE BATTERY PACK WAS REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 92,644 hrs · 12,371 cycles
FWD BATTERY PACK M33097 FAILED A CAPACITY CHECK. THE BATTERY PACK AND CHARGER WERE REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.
Part: SKIN — DAMAGED (BS 2150-2174) · airframe 92,644 hrs · 12,371 cycles
RIGHT AFT LOWER SKIN FOUND DAMAGED AT BS 2150 - 2174, STRINGERS 39R - 40R. THE SKIN WAS REPAIRED IAW ECRA 5330-06348, REV.
Part: ANGLE — CRACKED (BS 2370) · airframe 92,644 hrs · 12,371 cycles
LEFT BS 2370 PIVOT BULKHEAD FORWARD ANGLE INSPECTION FOUND CRACKED.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 92,644 hrs · 12,371 cycles
R3 DOOR BATTERY PACK M33404 CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND CAPACITY CHECKED WITH NORMAL RESULTS IAW AMM 33-51-06.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 92,644 hrs · 12,371 cycles
SEAT 2H AFT EMERGENCY LIGHT WILL NOT ILLUMINATE. THE EMERGENCY LIGHT LAMP WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-05.
Part: LIGHT — INOPERATIVE (SEAT 1H) · airframe 92,644 hrs · 12,371 cycles
SEAT 1H AFT EMERGENCY LIGHT INOPERATIVE. REPLACED AND OPS TESTED NORMAL IAW AMM 33-51-05.
Part: BULKHEAD WEB — CRACKED (BS 1287) · airframe 92,644 hrs · 12,371 cycles
BULKHEAD WEB BS 1287, BETWEEN LBL 18.3 AND 25.7, ONE CRACK WAS FOUND ON THE WEB LENGTH APPROX 2.7 INCHES. CRACKED AREA TRIMMED IAW DRAWING 624W0008 SHEET 8.HFEC. REPAIRED IAW EA 5300-01502.
Part: BULKHEAD WEB — CRACKED (BS 1281) · airframe 92,644 hrs · 12,371 cycles
BULKHEAD WEB BS 1287, BETWEEN RBL 18.3 AND 25.7, HAD ONE CRACK. LENGTH 2.3 INCHES. CRACKED AREA TRIMMED OFF IAW DRAWING 624W0008, SHEET 8, HFEC INSPECTION CARRIED OUT IAW NTM PART6 51-00-01, PROC 2, REV 71. NO CRACK AT TRIMMED EDGE. REPAIRED IAW EA 5300-01502.
2017
Part: ENGINE — LEAKING (NR 1) · airframe 90,867 hrs · 12,172 cycles
WHEN T/O THRUST SET, AN ODOR OF DIRTY SOCKS THAT .LASTED FOR 1 MINUTE. DUE TO HISTORY OF ODOR IN THE FLIGHT DECK, REPLACED THE NR 1 ENGINE IAW AMM 71-00-02 P401.
Part: UNKNOWN — ODOR (CABIN) · airframe 90,758 hrs · 12,158 cycles
STRONG DIRTY SOCKS ODOR STARTED ON DESCENT AT 5000 FT TO LANDING. ACCOMPLISHED ECRA 0551-01078 AND PACK BURN. NO SMOKE NOTED IN CABIN
Part: UNKNOWN — ODOR (CABIN-COCKPIT) · airframe 90,595 hrs · 12,139 cycles
STRONG ODOR IN COCKPIT AND CABIN AT TAKEOFF. DISSIPATED QUICKLY . RAN APU AND TURNED AC PACKS FOR AN HOUR NO ODOR NOTED RAN ENG FOR 5 MIN COULD NOT DUPLICATE ON GRND OK FOR SERVICE.
Part: WINDSHIELD — FAILED (L1) · airframe 90,559 hrs · 12,135 cycles
WINDOW HEAT LT FWD EICAS ADVISORY, LOSS OF LEFT FORWARD WINDOW HEAT. OUTER PANE CRACKED. EMERGENCY DECLARED. REMOVED THE L1 WINDOW IAW AMM 56-11-01 AND EA 3000-01084, REV B OP1. SPLICED WIRES W4123-1001-20, AND W4123-0111-20 IAW SWPM 20-30-12. LEFT WINDOW HEAT CONTROL SYSTEM TEST CHECKED GOOD.
Part: FILTER — DIRTY (RECIRC FAN) · airframe 90,153 hrs · 12,091 cycles
DURING TAKEOFF AND LANDING, AN ACRID MUSTY ODOR WAS NOTICED IN THE FLIGHT DECK FROM AIR CONS. CLEANED RECIRCULATION FAN FILTERS.
Part: UNKNOWN — ODOR (CABIN) · airframe 89,833 hrs · 12,054 cycles
STRONG ODOR IN COCKPIT WHEN THROTTLES AT IDLE. PERFORMED AN ENGINE RUN AND PACK BURN IAW JRH 2-200-36, NO STRONG ODORS NOTED.
Part: UNKNOWN — ODOR (CABIN) · airframe 89,241 hrs · 11,981 cycles
PREVIOUS FLT F/A SMELLED SMOKE AT 3R ON TAKEOFF FOR 1MIN/ WAS MILD RAN BOTH PACKS OFF OF APU AIR AND ENGINE BLEED. RAN ENGINES AT IDLE AND AT PART POWER. COULD NOT DETECT ANY ODORS IN FLIGHT DECK OR IN CABIN.
Part: ACM — FAULTY (AC BAY) · airframe 89,241 hrs · 11,981 cycles
CREW UPDATE TO OIL SMELL. APU WAS SHUTDOWN FOR APPROX 10 MIN, ODOR WAS PREVALENT IN FWD CABIN AND WAS ENOUGH TO SET OFF THE FWD CREW REST SMOKE ALARM MOMENTARILY. RESIDUAL SMELL REMAINED APPROX 15 MIN. RECIRC FANS ON-OFF DIDN'T MATTER. TOMC-EMC SMELL IS PRESENT NO MATTER WHAT PNEUMATIC SOURCE IS PROVIDING AIR TO PACKS. SMELL IS VERY STRONG WITH LEFT PACK RUNNING AND RECIRC FANS ON. STARTED TO ACCOMPLISH TASK 21-00-01-100-801 LEFT OFF ON PAGE 6 STEP 12D.SMELL IS STRONGER WHEN LEFT PACK IS SET TO COLD. ODOR CHANGES WHEN GOING TO WARM. STRONGEST IN FLIGHT DECK AND ABLE TO SMELL UP TO ROW 30. SMELL IS NOT NOTICEABLE FROM LEFT AND RIGHT ENGINE SUPPLY DUCT OR APU PNEU. DUCT AT HIGH PRESS. CONNECTORS. SEE LOG PAGES 4430041,4439506,4433246,4432654,4429464,4429418,44 30210 FOR BOTH LT AND RT AIR COND SYS MAINT. REPLACED LEFT AND RIGHT DUAL HEAT EXCHANGER PER MM21-52-01-000-801. REPLACED FWD AND AFT FLIGHT DECK MUFFLER ASSY'S IAW AMM 21-22-01-400-801. REPLACED LEFT PACK AIR CYCLE MACHINE REF AMM 21-52-02-400-801. PERFORMED ACP ENGINE AIR SUPPLY OPERATIONAL TEST PER AMM36-10-00-700-801 AND POWER ASSURANCE TEST PER 71-00-00-720-803. ALL TEST PASSED. NO OIL SMELL NOTED.
Part: ACM — DIRTY (LEFT) · airframe 88,955 hrs · 11,947 cycles
CREW REPORTED SMOKE IN COCKPIT ALSO EICAS FOR SMOKE IN FCR AT FL 050. CREW INVESTIGATED FCR BUT NOTHING SPECIFIC. CHECKED ALL RECIRCULATION AND GASPER FANS, FCR HEATER, NO EVIDENCE OF ELECTRIC BURNING CONDITION. ACCOMPLISHED REQUIRED TASKS OF ECS PER AVO ECS170404-2883-1 ALSO NO EVIDENCE OIL CONTAMINATION IN WATER COLLECTOR, OZONE CONVERTER, RE-HEATER/CONDENSER AND DUAL HEAT EXCHANGER. REPLACED ACM PER AMM 21-52-02-401. PERFORMED CABIN AIR TEMP CONT SYSTEM WITH BOTH ENG RUN AND ALSO USED APU. SAT.
2016
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 87,602 hrs · 11,804 cycles
EXTERIOR EMERGENCY LIGHT AT DOOR 1 LEFT IS INOPERATIVE. REPLACED THE LAMP. OPS CHECKED OK.
Part: UNKNOWN — ODOR (COCKPIT) · airframe 87,025 hrs · 11,728 cycles
CREW REPORTED SMOKE IN FLT DECK AND CABIN WITH ODOR. RETURNED TO FIELD. NO SPECIFIC CAUSE INITIALLY IDENTIFED. PERFORMED SMOKE / ODOR IN THE FLIGHT DECK/CABIN -CONDITIONAL INS PECTION REF AMM 05-51-50 REV.76, RESULT NORMAL.
Part: PIN — BROKEN (DOOR SLIDE) · airframe 86,310 hrs · 11,641 cycles
SLIDE PI-PIN ON TOP OF FWD LAVE DOOR THAT SLIDES THRU TRACK IN BROKEN R & R ROD, SPRING ASSY, GUIDE TRIM ASSY.
2014
Part: CONNECTOR — DIRTY (APU) · airframe 78,956 hrs · 10,875 cycles
CREW REPORT APU SHUTDOWN WITH FAULT ON PUSH BACK. REPEAT EVENT DUE TO ERRATIC OIL TEMP. REPLACED OIL TEMP SENSOR, NO HELP. APUC REPLACED, NO HELP. WIRING CHECKED GOOD. TROUBLE SHOT DOWN TO VLV TEMP CONTROLLER. CLEANED & RESEATED FIRE WALL CONNECTOR D49001P. WORKED WITH FIM TASK 49-20 TASK 808 & WDM 4-9-94-11.
Part: STRIP — CRACKED (NR 1 NACELLE) · airframe 75,924 hrs · 10,557 cycles
NR 1 ENG AFT FAIRING FIRE SHIELD GAP COVER STRIP HAS 1.5 INCH CRACK ON THE THIRD FIRE SHIELD SEGMENT. REMOVED DAMAGE CALCULATED LOSS IS .1085 SQ INCHES. ACCOMPLISHED HFEC OF EFFECTED AREA, NO CRACK INDICATIONS NOTED. NEED TO ACCOMPLISH FINAL DISPOSITION.
Part: STRIP — CRACKED (NR 1 NACELLE) · airframe 75,924 hrs · 10,557 cycles
NR 1 ENG AFT FAIRING FIRE SHIELD GAP COVER STRIP HAS 1.5 INCH CRACK ON THE THIRD FIRE SHIELD SEGMENT. REMOVED DAMAGE CALCULATED LOSS IS .1085 SQ INCHES. ACCOMPLISHED HFEC OF EFFECTED AREA, NO CRACK INDICATIONS NOTED. NEED TO ACCOMPLISH FINAL DISPOSITION. AMM 54-50-70 FIG 103 OK TO CONTINUE IN SERVICE FOR 24 MONTHS.
2013
Part: OXYGEN MASK — SCRATCHED (COCKPIT) · airframe 74,662 hrs · 10,415 cycles
CAPTAIN`S O2 MASK SCRATCHED. REPLACED CAPTAIN'S O2 FACE MASK. ACCOMPLISHED TEST OF MASK IAW AMM 35-11-00-501, MR35222 163 OFF, 193 ON. ACP MICROPHONE TEST, O2 FLOW CHECKED & STOWED MASK IN BOX.
Part: AUTOTHROTTLE SYS — MALFUNCTIONED · airframe 74,616 hrs · 10,408 cycles
AUTO THROTTLE ISSUE, UNCOMMANDED CHANGE IN THRUST MODE.
Part: PROBE — MALFUNCTIONED (PITOT/STATIC SYS) · airframe 73,957 hrs · 10,328 cycles
EICAS MESSAGE CENTER PITOT HEAT. REINSTALLED CENTER PITOT PROBE IAW MM34-11-01, COMPLETED THRU PARAGRAPH G. STEP 1. CENTER PITOT SYSTEM LEAK TEST IAW MM34-11-00-700-804, COMPLETED UP TO PARAGRAPH F STEP 7. STEP 8 EXISTING MESSAGE 34-25102 WILL NOT SHOW. COMPLETED TEST IAW MM 34-11-00, OPERATIONS CHECKED NORMAL.
Part: WIRE — DISCONNECTED (ELECTRICAL SYS) · airframe 73,957 hrs · 10,328 cycles
IAW DF823 & SMC65, B PHASE AC MISSING FROM CIRCUIT BREAKERS C23362, C21314 & C23361. FOUND FEEDER WIRE FROM C2 3361 B1 NOT CONNECTED TO C30408. SECURED WIRING IAW WDM 24-51-24.
Part: FAN — MALFUNCTIONED (CABIN) · airframe 73,957 hrs · 10,328 cycles
AFT UPPER RECIRCULATION FAN POPPED ITS CIRCUIT BREAKER. CIRCUIT BREAKER COLLARED, P210 B5 WDM 21-25-22. PN 566-9011 MR21756.
Part: B-NUT — LOOSE (NR 2 ENGINE) · airframe 73,957 hrs · 10,328 cycles
RAMP REPORTED AN OIL LEAK UNDER NR 2 ENG. OPENED COWL, TIGHTEN B-NUT ON ENG HYD PUMP LINE, MOTORED ENG. NO LEAKS NOTED DURING ENG MOTORING.
Part: PROBE — MALFUNCTIONED (PITOT/STAIC SYS) · airframe 73,957 hrs · 10,328 cycles
EICAS MESSAGE: CENTER PITOT HEAT. REINSTALLED CENTER PITOT PROBE IAW MM, COMPLETED THRU PARAGRAPH G. STEP 1. CENTER PITOT SYSTEM LEAK TESTED IAW MM 34-11-00-700-804, COMPLETED UP TO PARAGRAPH F STEP 7. STEP 8 EXISTING MESSAGE 34-25102 WILL NOT SHOW.
Part: SHUTOFF VALVE — FAULTY (AC BAY) · airframe 73,744 hrs · 10,303 cycles
TRIM AIR PRSOV RT PACK. DUE TO REPEATED HITS FOR RT PACK TRIM AIR PRSOV MSG 21-24202. PLEASE REPLACE THE RT TRIM AIR PRSOV V21622 646-9008 MR21670 AMM 21-62-01. INSTALLED NEW PRSOV IAW AMM 21-62-01, GROUND TEST PASSED OPERATIONS NORMAL.
Part: RELAY — NOT SEATED (PITOT HEAT) · airframe 73,688 hrs · 10,296 cycles
EICAS MESSAGE HEAT PITOT C DISPLAYED. FIM CONSULTED 30-31 T808. RELAY RESEATED & ADM CTR CONNECTOR CLEANED, MESSAGE GONE & MAT TEST PASSED.
Part: CLUTCH — OUT OF ADJUST (COCKPIT WINDOW) · airframe 73,054 hrs · 10,223 cycles
RT COCKPIT WINDOW WILL NOT OPEN OR CLOSE. HANDLE DISENGAGES. FOUND CLOSING HANDLE INTERNAL CLUTCH DISENGAGED. REMOVED HANDLE AND ADJUSTED CLUTCH, ALL OPS NOW NORMAL. INSPECTION CARRIED OUT AFTER REASSEMBLY.
Part: WARNING MESSAGE — ILLUMINATED (APU) · airframe 73,022 hrs · 10,220 cycles
APU CONTROL STATUS MESSAGE AFTER COLD SOAK START.
Part: THRUST REVERSER — WARNING MESSAGE (LT ENGINE) · airframe 73,008 hrs · 10,219 cycles
EICAS STATUS MESSAGE, LT THRUST REVERSER. NR 1 THRUST REVERSER SECURED AT FWD THRUST POSITION.
Part: SKIN — CHAFED (NR 2 NACELLE) · airframe 73,008 hrs · 10,219 cycles
NR 2 PYLON PANEL 443CL CUTOUT SKIN FOUND CHAFING. INSTALLED TITANIUM TRIPLER IAW ECRA 5430-01965 PART 1. ACCOMPLISH INITIAL INSPECTIONS IAW ECRA 5430-01965 PART 2.
Part: TRANSCEIVER — FAULTY (LT VHF) · airframe 73,008 hrs · 10,219 cycles
LT VHF TRANSCEIVER FOUND AN INTERNAL FAULT. REPLACED AND TESTED NORMAL IAW AMM.
Part: STRUCTURE — WORN (THRUST REVERSER) · airframe 73,008 hrs · 10,219 cycles
NR 2 ENG OTBD THRUST REVERSER COWL, UPPER RELIEF DOOR HAS BOTH LATCHING SURFACES WORN AWAY. PREVIOUSLY CF IAW ECRA 7831-01772. ACP'D INTERIM REPAIRED IAW ECRA 7831-01768 INSTALLED STAINLESS STEEL STRIKER PLATES AND REPLACED NEW LATCHES. PERMANENT REPAIR REQ IAW SRM 54-30-01, REPAIR 4 AT NEXT C-CHECK WITH MAX DATE OF 10 OCT 2013. 2 ENG OTBD THRUST REVERSER AFT COWL MID FRAME AND SKIN WEAR DMG AREA REPAIRED IAW SRM 54-30-01, REPAIR 4 FIG 202 AND (2EA) DAMAGED WEAR PLATE AND LATCH REPLACED IAW SRM 51-10-02 & (2EA) NEW WEAR PLATE & (2EA) NEW LATCH INSTALLED.
Part: DISPLAY — INOPERATIVE (CENTER) · airframe 72,728 hrs · 10,184 cycles
CENTER CDU DISPLAY BLANK. CIRCUIT BREAKER CYCLED AND CENTER CDU DISPLAY BACK TO NORMAL MOMENTARILY AND THEN WENT TO BLANK AGAIN. SWAPPED CENTER CDU WITH LT SIDE, SCREEN DISPLAYED, REINSTALLED CDU'S IN ORIGINAL LOCATIONS. REPLACED THE CENTER CDU.
Part: INDICATOR — ERRATIC (STAB POSITION) · airframe 72,531 hrs · 10,161 cycles
CAPTAIN'S STAB POS INDICATOR ERRATIC. REPLACED INDICATOR IAW MM, CHECKED OK.
Part: LINE — CHAFED (NR 4 BEARING SCA) · airframe 71,305 hrs · 10,028 cycles
DURING VISUAL INSPECTION, FOUND CLAMP CHAFING INTO NR 4 BEARING SCAVENGE TUBE LR06. REPLACED OIL LINE. FOUR CLAMPS REMAIN TO BE ATTACHED TO 12TH STAGE BLEED DUCT. COMPLETED SECURING CLAMPS ATTACHING NR 4 BEARING SCAVENGE TUBE TO 12TH STAGE BLEED DUCT. ENGINE RUN LEAK CHECK NORMAL.
Part: STEERING UNIT — FAILED (SATCOM) · airframe 71,164 hrs · 10,014 cycles
HIGH GAIN SATCOM FAILED. REPLACED LEFT STEERING BEAM UNIT PER MM. AFTER INTERROGATING SATCOM SYSTEM ON MAT. SYSTEM TEST OK.
2012
Part: MOTOR — FAULTY (WINDSHIELD WIPER) · airframe 70,399 hrs · 9,922 cycles
CAPTAIN`S WINDSHIELD WIPER AFTER 2 CYCLES MAKES SHORT WIPES. REPLACED WIPER MOTOR AND WIPER BLADE REF MM 30-42-03, WIPERS CHECKED OKAY.
Part: CONTROLLER — FAULTY (INTERPHONE) · airframe 68,588 hrs · 9,805 cycles
CABIN INTER BUSY SIGNAL HEARD ON COCKPIT HANDSET UNABLE TO CONTACT CABIN. REPLACED PACI PER MM, OPN CHECKED OK.
Part: CONTROLLER — INOPERATIVE (BLEED AIR SYS) · airframe 69,204 hrs · 9,782 cycles
LEFT MANIFOLD PRESSURE - FLOW SENSING SYSTEM INOPERATIVE. SAMC TEXT: FLIGHT CREW COMPLIED WITH MEL. OPBLM DEFERRED PER SAMC. REPLACED LEFT ASCPC PER MM, OPS CHECK NORMAL PER MAT.
Part: COUPLING — DAMAGED (HYD LINE) · airframe 68,288 hrs · 9,681 cycles
NR 1 ENG HYD DRAIN LINE COUPLING IN NR 1 ENG SAIL COMPARTMENT IS DAMAGED. SECURED DRAIN LINE COUPLING.
Part: VENT — UNKNOWN (NACELLE) · airframe 66,903 hrs · 9,525 cycles
NACELLE VENT SO VALVE (L ENG CH B) POWER CIRCUIT IS OPEN. REPLACED L NAC ZONE VENT SHUTOFF VALVE, NO HELP. CHECKED WIRES & CONNECTOR REF FIM 75-23 TASK 802. ALL CHECKED OK. REPLACED EEC, ALL TEST CHECKED GOOD, MESSAGE DID NOT SHOW.
Part: PUMP — LEAKING (NR 1 ENGINE) · airframe 66,856 hrs · 9,521 cycles
NR 1 ENGINE HYDRAULIC PUMP CASE DRAIN LEAKING 12 DROPS PER MIN LIMIT IS 6 DPM PER MM. CHANGED PUMP IAW MM 29- 11-05. STILL LEAKING HYD FLUID FROM PUMP CASE DRAIN LINE. WHILE ENG RUNNING LEAK IS AT 50 DROPS PER MINUTE. NOT RUNNING LEAK IS AT 25 DROPS PER MINUTE. MR 29116 DASH 29 REMOVED MR 29116 DASH 27 INSTALLED. REMOVED PUMP MR29116-27 REF AMM. INSTALLED NR 1 ENG DRIVEN HYD PUMP PER NOTED MM. RAN ENG 1 PER JRH, HYD PUMP OPS NORMAL.
Part: CONNECTOR — FAULTY (TRIM AIR) · airframe 66,672 hrs · 9,499 cycles
TRIM AIR LT STATUS MSG WHEN APU OFF. RPL'D BENCH PLUG TWINA X 1T ON DM21631AA REF WDM AND SWPM. CTC-L OPS CHECKED GOOD. NO STATUS MSG. RAN PACKS, ALL INDICATIONS NORMAL.
Part: CONNECTOR — WRONG PART (CABIN) · airframe 66,671 hrs · 9,498 cycles
STATION 1840 LBL 90, 2 EACH WRONG CONNECTORS INSTALLED. REF FCD 3321-01019 PAGE 32 ITEM 8. REPLACED CONNECTOR.
Part: LIGHT — DEFECTIVE (FUSELAGE) · airframe 66,551 hrs · 9,481 cycles
CEILING LIGHT ASSY L33146 LOCATED AT STA 1520 LBL 90, CONNECTOR IS NON COMPLIANT PER FCD NO 3321-01018 REV B STEP 19 PG 8 OF 27. REPLACED CEILING LIGHT ASSY, OPS NORMAL.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 66,551 hrs · 9,481 cycles
CEILING LIGHT ASSY ABOVE LT AFT LAV 141 STA 1980 LBL 90, ACFT CONNECTOR (SOCKET) SIDE IS NON COMPLIANT. CONNECTOR MIS MATCHED WITH VIKING BACC65AK211P. PER FCD NO 3321- 01018 REV B. REPLACED CONNECTOR WITH CORRECT CONNECTOR.
Part: SLIDE — DEFECTIVE (R1 DOOR) · airframe 66,291 hrs · 9,445 cycles
R1 DOOR SLIDE PACK RELEASE MECHANISM FUSE IS NOT INSTALLED. REMOVED THE SLIDE ON THE R1 DOOR. INSTALLED THE NEW SLIDE ON THE R1 DOOR REF AMM 25-66-01 P401. ACP RII INSPECTION PER ALL CRITICAL STEPS IN GMM 09-25-05.
Part: SKIN — DAMAGED (FUSELAGE) · airframe 66,291 hrs · 9,445 cycles
SKIN DAMAGE FROM LIGHTNING STRIKE STA 487 STR 39. REPAIRED REF SRM 53-00-01 RPR 8. INSTALLED BLIND FASTENER NEED RE-CKS AT 4000C AND REPLACE AT 16000C. REMOVED THE BLIND RIVET. PERFORMED HFEC INSPECTION OF THE HOLE. NO CRACK INDICATION. INSTALLED A SOLID FASTENER PER SRM 53-00-01 REPAIR 8.
2011
Part: SWIVEL FITTING — CRACKED (LT MLG) · airframe 65,975 hrs · 9,409 cycles
TUBE ASSY ATTACH AT SWIVEL LT MLG DRAG BRACE. SWIVEL FITTING IS CRACKED. REPLACED SWIVEL FITTING IAW MM.
Part: CIRCUIT CARD — MALFUNCTIONED (APU BATTERY) · airframe 65,831 hrs · 9,393 cycles
APU BATTERY OVERHEAT STATUS MESSAGE DISPLAYED ON EICAS. REPLACED APU BATTERY, NO HELP. SIGNAL CONDITIONING CARD REPLACED REF AMM & DIODE 405 POS-12 IN P310 REPLACED REF WDM 24-09-26 PG 1-SHT2, NO MESSAGES PRESENT AFTER 4 HRS OF ACFT POWER -ON-, WITH MULTIPLE SWITCHING OF POWER FROM APU-GND, POWER ON-OFF-ON. APU STARTED NORMAL. REPLACED P310 SCC, TESTED OK NO FAULTS.
Part: MODULE — FAULTED (ELETRICAL SYS) · airframe 65,831 hrs · 9,393 cycles
ELECTRICAL STANDBY SYS STATUS MESSAGE DISPLAYED. MAINTENANCE MSG 24-13044, PER FIM 24-32-TASK 806. REPLACED RELAY K24300, NO HELP. CHECKED POWER AT PIN 2 OF CB D6 (P310) 28VDC. REPLACED DC STANBY CARD M24406A12 AND SPECIAL FILTER CARD M24406A19 PER MM, NO HELP. NOW HAVE MAINT MSG'S 24-13039 & 24-13035. (MODULE P/N ELM417-2, SERIAL# E7236 - POSIT 1). REPLACED SIGNAL CONDITIONING CARD ASSY IN P310 STANDBY POWER PANEL REF MM. REPLACED RELAY K24020 AND RELAY K24016 FOUND TO BE DAMAGED AND CHECKED TB405 PINS 2A AND 2B LOOKS GOOD. MESSAGE WENT AWAY, NO EXISTING FAULTS NOTED ON MAT.
Part: GENERATOR — FAULTY · airframe 65,074 hrs · 9,290 cycles
APU GENERATOR DROPPED OFF LINE. CYCLED SWITCH COUPLE TIMES NOT COMING ON LINE. APU GENERATOR WILL NOT COME ON LINE. REPLACED APU GENERATOR. REPLACED GENERATOR SCAVENGE FILTER.
Part: IDG — FAULTY (NR 1 ENGINE) · airframe 64,883 hrs · 9,266 cycles
LEFT ENGINE GENERATOR DID NOT COME ON LINE AT ENGINE START. CYCLED GEN CTL SWITCH NO CHANGE. GEN DRV LIGHT ILLUMINATED BRIEFLY THEN WENT OUT WHEN OPPOSITE ENGINE WAS SHUT DOWN. NO STATUS MSGS OR EICAS ADVISORY MSGS FOR GEN DRIVE. CREW DID NOT DISCONNECT GENERATOR. SAMC MORRISSEY PROG TEXT: - ITEM ROLLED FORWARD. DEFERRED LT IDG. -INF- :IDG OIL SHOULD BE CHANGED WHEN DEFERRAL IS CLEARED. RPL'D GCU NO HELP MR24241 ON 149 OFF 121. -INF- :GCU REPLACED REF MM24-22- 02 DID NOT HELP. REPLACED L-ENG IDG, OP CHECKS GOOD ON ENG RUN, NO LEAKS, NO FAULTS.
Part: IDG — FAULTY (NR 1 ENGINE) · airframe 64,882 hrs · 9,265 cycles
L ENG OFF & DRIVE LIGHT STAYED ON AFTER ENG START, NO STATUS NO EICAS. CYCLED GEN CTL SWITCH NO CHANGE. GEN DRV LIGHT ILLUMINATED BRIEFLY THEN WENT OUT WHEN OPPOSITE ENGINE WAS SHUT DOWN. NO STATUS MSGS OR EICAS ADVISORY MSGS FOR GEN DRIVE. CREW DID NOT DISCONNECT GENERATOR. DEFERRED LT IDG. IDG OIL SHOULD BE CHANGED WHEN DEFERRAL IS CLEARED. REPLACED GCU, NO HELP. GCU REPLACED, DID NOT HELP. REPLACED L-ENG IDG, OP CHECKS GOOD ON ENG RUN, NO LEAKS, NO FAULTS.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 64,794 hrs · 9,253 cycles
LLAR PBE FOUND SOFT. REPLACED PBE.
Part: O2 GENERATOR — DISCHARGED (CABIN) · airframe 64,794 hrs · 9,253 cycles
LLAR BED 'BAY 4'. O2 GENERATOR FOUND DISCHARGED. REPLACED O2 GENERATOR ON PSU. UPON ASSY FOUND DOOR LATCH WILL NOT SECURE. TAPED DOOR CLOSED PER MEL INSTRUCTIONS. IPC REF NR 1. P/N 418W1080-2241A, N/S UAL. MEL ALSO REQUIRES DEFERAL OF ASSOCIATED SEAT PER MEL CARD 25050. ALSO USING MEL CARD 25008 AS THIS IS THE LLAR. RPR RESET DOOR.
Part: O2 GENERATOR — DISCHARGED (CABIN) · airframe 64,794 hrs · 9,253 cycles
LLAR BED 'BAY 4'. O2 GENERATOR FOUND DISCHARGED. REPLACED O2 GENERATOR ON PSU REF MM. UPON ASSY FOUND DOOR LATCH WILL NOT SECURE. TAPED DOOR CLOSED PER MEL INSTRUCTIONS. IPC REF 35-11-18-011 ITEM NR 1. P/N 418W1080-2241A, NS UAL. MEL ALSO REQUIRES DEFERL OF ASSOCIATED SEAT PER MEL CARD 25050. ALSO USING MEL CARD 25008 AS THIS IS THE LLAR. RPR RESET DOOR.
Part: UNKNOWN — ODOR (CABIN) · airframe 64,782 hrs · 9,251 cycles
SMOKE ODOR NOTICED BY DOOR 2L. ACCOMPLISHED FIM TASK.
Part: COVER — DAMAGED (EVAC SLIDE) · airframe 64,568 hrs · 9,224 cycles
THE 4L SLIDE COVER HAS DENTS AND HOLES. FOUND DENT 1 IN X 0.5 IN AT MIDDLE OF SLIDE RAFT COVER. REMOVE AND INSTALL 4L DOOR SLIDE BUSTLE FOR INSPECTING THE SMALL DENT ON THE BUSTLE. THIS IS RII ITEM. ACP A FILLER REPAIR, VERY MINOR FILLER PATCH REQUIRED, SLIDE COVER OK FOR SERVICE. OK TO TAKE TO C-CK PER OPBLM. ACCMP'D RII INSPECTION FOR BUSTLE CONDITION AND REMOVAL INSTALLATION. BUSTLE INSIDE NO DAMAGE. ALSO NO DAMAGE ON SLIDE PACK. BUSTLE CHKS OKAY.
Part: LIGHT — INOPERATIVE (EXTERIOR) · airframe 64,305 hrs · 9,194 cycles
DOOR 1 LT EMERGENCY EXIT EXTERIOR LIGHT INOP DURING TEST AT P-40 PANEL. RELAMPED LT DOOR EXT EMERGENCY LAMP, OPS CHECK OK.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER A' CHECK PAPERWORK, PBE SPONGY BY DOOR 4L. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY BY DOOR 2L. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY BY DOOR 3L. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY BY DOOR 2R. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY BY DOOR 1L. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY BY DOOR 3R. REPLACED PBE.
Part: PBE — UNSERVICEABLE (CABIN) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY BY DOOR 4R. REPLACED PBE.
Part: PBE — UNSERVICEABLE (COCKPIT) · airframe 63,862 hrs · 9,135 cycles
PER 'A' CHECK PAPERWORK, PBE SPONGY. IN FLIGHT DECK STOWAGE COMPT. REPLACED PBE.
Part: IDG — MALFUNCTIONED (RIGHT)
RT GENERATOR DRIVE MSG. DISCONNECTED IDG.
Part: BLADES — DAMAGED (HP COMPRESSOR) · airframe 62,875 hrs · 9,016 cycles
NR 2 ENGINE FOUND MOST HPC STAGE 13 AND 15 BLADES WITH L/E IMPACT DAMAGE. BLADES EXCEED LIMITS IN AREAS 'A','B','C' AND 'E' THAT ARE ALLOWED. PIC'S POSTED & OPBLM & SFOEP CONTACTED. REMOVED NR 2 ENGINE. INSTALLED ENGINE IN POSITION NR 2.
Part: BLADES — DAMAGED (COMPRESSOR) · airframe 62,875 hrs · 9,016 cycles
NR 2 ENGINE FOUND MOST HPC STAGE 13 & 15 BLADES WITH L/E IMPACT DAMAGE EXCEEDING LIMITS. EXCEED LIMITS IN AREAS 'A','B','C' AND 'E' THAT ARE ALLOWED. REQUIRES ENG CHANGE. REMOVED NR 2 ENG. THIS IS PRECAUTIONARY DUE TO ECM PARAMETER SHIFT. IF CAN CONTINUE IN SERVICE AT REDUCED INSPECT INTERVAL, UPDATE CALLOUT EC4001 AND-OR EC4011 WITH INTERVAL AND FINDINGS. IF HPT OK, BORESCOPE HPC COMPRESSOR BLADES STG 5, 6, 7, 9, 11, 13. IF IN LIMITS BUT EVIDENCE OF IMPACT, BORO ALL STAGES HPC. DMG LESS THAN ABOUT 0.1 INCH DEEP MAY BE ON-WING BLENDABLE, CONTACT SFOPI FOR RPR 72-00-00 RU06. FOUND HPT BLADE AND HPC 13 AND 15 WITH DAMAGE THAT EXCEED THE MM LIMITS. PER OPBLM. NO NEED TO CONTINUE WITH THE REST OF THE COMPRESSOR BORESCOPE. ENG CHANGE REQUIRED.
Part: MODULE — FAULTY (CABIN) · airframe 62,738 hrs · 9,003 cycles
AT 10AB, ELECT ODOR PRESENT. TURN OFF IFE POWER SWITCH IN COCKPIT. FIRST TRIED SEAT POWER AT INDIVIDUAL SEATS, NO HELP. SAMC TEXT: IMMEDIATELY PRIOR TO LANDING, CREW SELECTED POWER ON TO RESET SEATS UPRIGHT FOR LANDING, ODOR RETURNED, SECURED SW OFF. MAINT TEXT: SHOULD READ SEAT 10-CD ELECTRIC ODOR. FOUND 10CD SEAT POWER MODULE INOP AND A STRONG ELECTRICAL SMELL COMING FROM SPM. REPLACED SPM PN RD-FA3621-01 S/N OFF 033693 S/N ON 033067. INSPECTED ASSOCIATED WIRING WITH NO DEFECTS NOTED. 894457 CHARGED TWO LAPTOPS AT 10CD POWER OUTLETS AND OPERATED IFE FOR 3HRS ON GROUND. NO ELECTRICAL SMELL NOTED. 10CD IFE OPS CHECK GOOD. WORK COMPLETED PER MM.
Part: TRANSMITTER — FAULTY (RT ENGINE) · airframe 62,529 hrs · 8,979 cycles
ENG EEC C1 R RIGHT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. REPLACED TRANSMITTER, NEED POWERPLANT TEST 3 & 6 DURING RUN. RAN ENG AND ACP TEST 3 AND 6. NO FAULTS. NO LEAKS.
Part: SHUTOFF VALVE — FAULTY (HYDRAULIC SYS) · airframe 62,529 hrs · 8,979 cycles
RT HYD SYSTEM WING SHUT OFF VALVE WILL NOT OPEN OR CLOSE. REPLACED RT WING HYD SHUTOFF VALVE PER MM.
Part: WIRE HARNESS — DAMAGED (RT ENGINE) · airframe 62,529 hrs · 8,979 cycles
THREE CLAMPS DAMAGED AT 11:00 POSITION ON RT ENGINE HARNESS W0623. CLAMPS PCN 223-0468. 4 EA. ON AOG K0707 TO IAD. RT ENGINE HARNESS W0623 IS DAMAGED AT 11:00 POSITION. DAMAGE IS BEYOND LIMITS OF SWP. IAD WILL POST RVI PICTURES. REPLACED NR 2 ENG WIRE HARNESS W0623 PER AMM.
Part: SHUTOFF VALVE — UNSERVICEABLE (NR 2 ENGINE) · airframe 62,101 hrs · 8,937 cycles
NR 2 ENGINE OB TVBC INDICATOR PIN MISSING. NR 2 ENGINE OB TVBC VALVE INDICATOR PIN MISSING. REMOVED OB TVBC AIR SHUTOFF VALVE. REPLACED TVBC VALVE PER MM, OPS CHECK GOOD.
Part: PCU — LEAKING (POS LT) · airframe 61,775 hrs · 8,905 cycles
LT INBD FLAPERON PCU LEAKING BEYOND LIMITS. REPLACED LT INBD FLAPERON POWER CONTROL UNIT IAW MM. UNIT WITHIN TOLERANCE.
Part: OIL TANK — UNDERSERVICED (ENGINE) · airframe 61,692 hrs · 8,897 cycles
ECM DATA SHOWING HIGHER THAN NORMAL OIL USAGE. 6 QTS ADDED AT END OF FLT. NO EXTERNAL LEAKS FOUND AFTER HIGH POWER RUN. NO OIL FOUND FROM B & B ALSO. OIL CONSUMPTION IS WITHIN LIMITS.
Part: ISOLATION VALVE — FAULTY (LEFT) · airframe 61,666 hrs · 8,895 cycles
LEFT BLEED ISOLATION VALVE NOT IN COMMANDED POSITION. STATUS MESSAGE 01- ACTIVE CRUISE MODE DEPENDENT; ISOLATION VALVE (LT) FAILED CLOSED. DB- AIR SUPPLY & CABIN PRESSURE CONTROLLER (R) MSG-3610280 ACTIVE ER MODE. REPLACED LT ISOLATION VALVE IAW MM.
Part: INSULATION — TORN (THRUST REVERSER) · airframe 61,555 hrs · 8,883 cycles
DURING A-CHECK, FOUND NR1 ENG OTBD REV INSULATION MISSING. NEED TO ID PARTS AND REMOVE OLD TORN INSULATION.
Part: COUPLER — FAULTY (HF RADIO) · airframe 61,555 hrs · 8,883 cycles
HF RADIO - RECEPTION PROBLEM. POOR RECEPTION. CHRONIC ITEM. LT HF RADIO. HISTORY BACK TO 24DEC. REPLACED LT HF ANTENNA COUPLER IAW MM. SYSTEM CHECKED GOOD WITH MM.
Part: WINDOW — CRACKED (SEAT 44K) · airframe 61,555 hrs · 8,883 cycles
POSSIBLE CRACK IN WINDOW OTBD OF SEAT 44K. R & R CABIN WINDOW ASSY (120-4066).
Part: WINDOW — DAMAGED (COCKPIT) · airframe 61,473 hrs · 8,875 cycles
COCKPIT WINDOW SHOWS SIGNS OF DAMAGE. L2 WINDOW VISIBILITY IMPAIRED BY CRAZING. AS A RESULT OF DAMAGE CAUSING IMPAIRED VISION, THE L2 WINDOW REQUIRES REPLACEMENT. REPLACED WINDOW IAW MM, OPS CKS GOOD.
Part: LAMP — CONTAMINATED (EMERGENCY LIGHT) · airframe 61,331 hrs · 8,858 cycles
CREW REPORTED SMOKE FROM LAMP. FLT ATTENDANT DISCHARGED HAND HELD HALON FIRE EXTINGUISHER ON LAMP. AFTER BOTTLE WAS DISCHARGED. CREW CONTACTED MX. PER CREW CABIN LIGHTS SET TO OFF IN AFT GALLEY AND LIGHT WENT OUT. CREW REMOVED LAMP PER SAM. SMOKE ALARM NEVER WENT OFF. READING LIGHT BUNK 5 UNCONTROLLABLE. INSPECTED LAMP ASSY FOR HEAT DAMAGE. NOTHING ABNORMAL OBSERVED. FOUND FILAMENT CONTAMINATED. INSTALLED NEW FILAMENT AND RESET IFE SYS POWER. READING LT OPS NOW NORMAL.
Part: SMOKE DETECTOR — NO TEST (CREW REST) · airframe 61,271 hrs · 8,851 cycles
FLIGHT CREW REST UPPER BUNK SMOKE DETECTOR FAILED ALL TEST. CONNECTED TO OEU 1-1-4. LOADED OEU OPS AND DATABASE, NO HELP. TRIED NEW OEU, LOADED OPS AND DATABASE AND TRIED SMOKE DETECTOR -R1 FROM LAV 1L, STILL NO HELP.
2010
Part: DRAIN LINE — MISSING (NR 2 NACELLE) · airframe 60,655 hrs · 8,788 cycles
DURING WALKAROUND FOUND NR 2 ENGINE WITHOUT DRAIN LINE PROTRUDING FROM PANEL 427AL OR THE SAME PANEL ON THE OTBD SIDE OF STRUT FAIRING. INSTALLED DRAIN TUBE ON EACH SIDE OF ENG AT PANEL 427AL. TUBES SECURE AND DRAINS CLEAR.
Part: SHUTOFF VALVE — INOPERATIVE (BLEED SYSTEM) · airframe 60,497 hrs · 8,764 cycles
UPON TAXI OUT, RT BLEED WENT INOPERATIVE. FOUND HPSOV ON NR 2 ENG BINDING, LUBRICATED. PERFORMED OPERATIONAL CHECK WITH ENGINE RUNNING. RT BLEED SYSTEM OPERATION OK. WORK PERFORMED BY BAHMM. DUE NUMEROUS DELAYS. PREVIOUS MAINTENANCE STATION HAD FOUND MANUAL OVERRIDE LEVER STUCK AND BINDING. THIS MAY CAUSE INCORRECT OVER PRESSURE SIGNAL TO PRSOV CAUSING A CHRONIC PRSOV PROBLEM ON THIS ACFT. HPSOV MUST BE REPLACED W-O DEVIATION. REPLACED HPSOV IAW AMM, OPS CHECKS GOOD.
Part: PROBE — FAULTED (FUEL SYSTEM) · airframe 59,277 hrs · 8,611 cycles
FUEL IMBALANCE EICAS AFTER T/O. FOUND FUEL INDICATOR STUCK APPROX 62,000 LBS IN LT MAIN TANK. ALL FILL VALVE OPS CHECKED OK. SUSPECT LT MAIN TANK SINGLE POINT SENSORS 11 AND 20 ARE BAD. REPLACED PROBES NR11 & 20 IAW MM, OP'S CHECK`S OK.
Part: SKIN — SCRATCHED (FUSELAGE) · airframe 59,193 hrs · 8,599 cycles
FUSELAGE SCRATCHED AT BS 920 STR 28R. MAJOR REPAIR ACCOMPLISHED: REPAIRED AT C CHECK ON WU K3083E AS PER SRM REPAIR 4. INITIAL HOLES ZERO TIMED. ACP'D CATEGORY B REPAIR PER SRM 53-00-01 REPAIR 4 AT BS 920 BETWEEN S-28R AND S-29R. REMOVED DAMAGE, ZERO TIMED FASTENER HOLES IN CRITICAL ROW AND INSTALLED A DOUBLER ON SMB N-R K3083E.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 58,207 hrs · 8,470 cycles
EMERGENCY LIGHT INOP ON SEAT 3F FWD. RELAMPED LIGHT ASSY. CHECKED NORMAL ON GROUND.
2009
Part: CONTROLLER — FAULTY (BLEED SYSTEM) · airframe 56,841 hrs · 8,266 cycles
BLEED PRSOV R RT ENG BLEED PRESSURE REGULATING SHUTOFF VALVE (PRSOV) FAILED OPEN OR CLOSED OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG-3610380 LATCHD ER MODE REMOVED AND REPLACE THE FOLLOWING NR 2 ENG PRSOV, PRSOV CONTROLLER AND HPSOV. OPS CHECK ON ENG RUNS GOOD. ALL PRESSURE NORMAL.
Part: EXCITER — FAULTY (ENGINE) · airframe 56,485 hrs · 8,217 cycles
ENGINE IGNITER L2 STATUS MESSAGE. NO STATUS MSG ON ARRIVAL, DUE PREVIOUS FAULTS ON ENG REPLACE EXCITER LEAD AND PLUG AT NEXT AVAIL MAINT. REPLACED EXCITER, REPLACED EXCITER TO IGNITER PLUG CABLE. REPLACED IGNITER PLUG. OPS CHECK GOOD.
Part: PLATE — DAMAGED (EXIT SIGN) · airframe 56,309 hrs · 8,188 cycles
EMERGENCY EXIT SIGN AT DOOR 1R HAS LENS TAPED ON. FOUND PLASTIC MOUNT THAT ATTACHES TO DOOR FRAME BROKEN LENS IS OK. NEED NEW MOUNTING PLATE. EXIT SIGN IS LOCATED JUST AFT OF DOOR ABOUT 36 INCHES UP FROM FLOOR. REPLACED LIGHT ASSY - TESTS OKAY.
Part: CABLE — OUT OF TOLERANCE (RUDDER PEDAL) · airframe 56,092 hrs · 8,164 cycles
CAPT'S RUDDER PEDALS WON'T STAY IN POSITION SELECTED, PEDALS TRAVEL ALL THE WAY TO THE FLOOR WHEN PUSHED ON WITH FOOT PRESSURE. ABLE TO DUPLICATE CAPT'S RUDDER PEDALS SLIP FROM POSITION SELECTED AND TRAVEL TO THE FLOOR, FOUND PEDAL TRAVEL ADJUSTMENT CABLE AT FAULT. DISASSEMBLED, INSPECTED & REASSEMBLED. OPERATIONS NORMAL.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 56,039 hrs · 8,157 cycles
EXT EMERGENCY LIGHT AT DOOR 3L INOP. RELAMPED, OP NORMAL.
Part: SEAL — LEAKING (RT ENGINE) · airframe 55,745 hrs · 8,121 cycles
OIL DRIPPING OUT OF RT ENG DRAIN TUBE NR 3 (BUG-MAIN GEARBOX). ACCOMPLISHED LEAK CHECKS AND STATIC LEAK WAS LESS THAN 6 DROPS PER MINUTE AND DURING ENGINE RUN LEAK RATE WAS BETWEEN 25 AND 30 DROPS PER MINUTE. ADDED ONLY ONE QUART TO SERVICE TO FULL. REQUIRES DRIVE SEAL REPLACEMENT. REPLACED NR 2 BACKUP GEN DRIVE OIL SEAL ASSY AND REINSTALLED NR 2 BACKUP GEN. RAN PER JRH, NO LEAKS NOTED.
Part: LAMP — NO TEST (L3 DOOR) · airframe 55,470 hrs · 8,085 cycles
DOOR 3L SLIDE LIGHT DOES NOT ILLUMINATE WITH TEST SWITCH ON P40 APU PANEL AT NLG. RELAMPED DOOR 3L SLIDE LIGHT. RELAMPED.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 54,801 hrs · 8,000 cycles
EEL LIGHT STRIP ON SIDE OF SEAT 2F IS INOPERATIVE. REPLACED LIGHT ASSY, OP CHECKS GOOD.
Part: SOCKET — MISINSTALLED (LAVATORY) · airframe 54,714 hrs · 7,991 cycles
LAV 142 NOTED BURNING ELECTRICAL SMELL FROM MIRROR LIGHT. FOUND MIRROR LIGHT TUBE INCORRECTLY FITTED. FOUND LIGHT TUBE PIN BENT AND CAUSING ARC AND MELTED THE HOLDER ASSY. DISCONNECTED BALLAST PLUG AND CAPPED AND REMOVED MIRROR LIGHT TUBES. REQUIRES NEW END HOLDER ASSY. REPLACED LAMP HOLDER ON LIGHT FIXTURE, OP CHECKED GOOD.
Part: SWITCH — FAULTY (APU) · airframe 54,151 hrs · 7,919 cycles
APU APUC DETECTED FAULT THAT WOULD CAUSE AUTOMATIC SHUTDOWN OF APU IN UNATTENDED MODE OPERATION, OR COMPLETE LOSS OF APUC BUS ACTIVITY (BOTH L AND R 629) FOR 3 SECONDS AFTER THE APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TEN SECONDS. STATUS CREW COMMENTS: MOMENTARY APU LIMIT EICAS MSG DURING NORMAL SHUTDOWN. MSG-4910270 INACTV PO MODE. -MAT MSG 49-12970. REPLACED LOW OIL PRESSURE SWITCH. RAN APU, NO LEAKS NOTED. NO MSG PRESENT. REMOVED AND REINSTALLED GEN BYPASS SWITCH. NO LEAKS NOTED. SECURED SWITCH. NO LEAKS NOTED.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 53,821 hrs · 7,878 cycles
SEAT EMERGENCY LIGHTS INOP AT SEAT 19G, 22G AND 37C. RELAMPED EMERGENCY LIGHTS, OPS CHECK OKAY.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 53,821 hrs · 7,878 cycles
SEAT 2E FWD EMERGENCY LIGHT INOP. REPLACED LAMP ASSY, OPS CHECK NORMAL.
Part: CONNECTOR — UNSECURE (EMERGENCY LIGHTS) · airframe 53,821 hrs · 7,878 cycles
SEAT 1E BOTH FWD AND AFT EMERGENCY LIGHT INOP. SECURED CONNECTOR, OPS CHECK NORMAL.
Part: LIGHT — MISSING (CABIN) · airframe 53,090 hrs · 7,784 cycles
EMERGENCY EXIT LIGHT STRIP ON SEAT 1EF IS MISSING. WIRES HAVE BEEN TAPED AND SECURED, NO PARTS AVAIL AT LAX. REPLACED LIGHT ASSY, DID NOT LIGHT UP. FOUND TWO BROKEN WIRES WHICH SHOULD BE CRIMPED TO THE MALE CONNECTOR OF ONE OF LAMP ASSY. LAMP ASSY CHECK GOOD. NEED CABLE WITH NEW CONN AND PINS. REPLACED EMERGENCY LIGHT CABLE. CHECKED OK.
Part: LIGHT — MISSING (CABIN) · airframe 53,090 hrs · 7,784 cycles
EMERGENCY EXIT LIGHT STRIP ON SEAT 1EF IS MISSING. WIRES HAVE BEEN TAPED AND SECURED, NO PARTS AVAIL AT LAX. REPLACED LIGHT ASSY DID NOT LIGHT UP. FOUND TWO BROKEN WIRES WHICH SHOULD BE CRIMPED TO THE MALE CONNECTOR OF ONE OF LAMP ASSY. LAMP ASSY CHECK GOOD. NEED CABLE WITH NEW CONN AND PINS.
Part: BATTERY PACK — DISCHARGED (R4 DOOR) · airframe 52,812 hrs · 7,748 cycles
DOOR 4 RT EPAS WILL NOT TEST. REPLACED EPAS BATTERY AND BACKUP BATTERIES PER MM 52-11-20. OPS CHECK GOOD.
Part: SLIDE — UNSERVICEABLE (R4 DOOR) · airframe 52,698 hrs · 7,735 cycles
DOOR 4 RIGHT SLIDE NEEDS REPLACEMENT DUE TO SLIDE BECOMING UNPACKED. SLIDE ON SITE AND RESERVED. REPLACED SLIDE.
Part: CABLE — FAULTY (R4 DOOR) · airframe 52,698 hrs · 7,735 cycles
DOOR 4R WILL NOT DISARM AT ARRIVAL. FOUND DOOR WITH ICE BY THE GIRT BAR. REMOVED ICE FROM DOOR SILL. OPEN DOOR AFTER DISARMING. FOUND DISARMING HANDLE TIGHTER THAT USUAL. RECOMMEND REPLACE CABLE NEXT MM OPPORTUNITY. REMOVED DOOR COVERS, GAIN ACCESS TO PUSH-PULL CABLE, ACP RIG ON DOOR CABLE, ADJUSTED AFT GIRT BAR MECHANISM, NR 4 RIGHT DOOR ARMS AND DISARM NORMAL.
2008
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 52,268 hrs · 7,685 cycles
SEAT EMERGENCY LIGHTS INOP AT SEATS 3F AND 24C. RELAMPED SEAT 24C AND REPLACED LENS. SEAT 3F NEEDS ELEC HARNESS 566-1375 AOG T0501. SIDE OF SEAT REMOVED FOR ACCESS. REPLACED HARNESS AND LT ASSY AND CHECKED 3F EMERGENCY LIGHTS, WORKS NORMAL.
Part: STRUCTURE — DAMAGED (FUSELAGE) · airframe 52,268 hrs · 7,685 cycles
LIGHTNING STRIKE, FOUND 11 HITS INSIDE RT RVSM AREA. REPAIRED AS REQUIRED PER SRM 53-00-01-RPR 8.
Part: LIGHT — MISSING (CABIN) · airframe 51,728 hrs · 7,615 cycles
EEL LIGHT MISSING ON SEAT 1E. DISCOVERED LIGHT MISSING. REPLACED MISSING EEL LIGHT ASSEMBLY, TESTS GOOD.
Part: UNKNOWN — UNKNOWN (IGNITER) · airframe 51,067 hrs · 7,537 cycles
SLOW LIGHT OFF ON NR 1 IGNITOR.
Part: LIGHT — MISSING (CABIN) · airframe 50,607 hrs · 7,481 cycles
AFT EMERGENCY LIGHT STRIP AT SEAT 1E MISSING. *S/D* FOUND LIGHT STRIP MISSING. REPLACED LIGHT STRIP, OP CHECKED GOOD. AC OK FOR SERVICE.
Part: START VALVE — FAULTY (NR 2 ENGINE) · airframe 50,423 hrs · 7,460 cycles
NR 2 ENGINE START VALVE INOP. *S/D* FOUND FAULTY START AIR VALVE. REPLACED PER MM80-11-02, OP CHECKED GOOD. AC OK FOR SERVICE.
Part: PRECOOLER — CRACKED (NR 1 ENGINE) · airframe 50,064 hrs · 7,423 cycles
LEFT ENGINE PRECOOLER LEAKING BEYOND LIMITS. *S/D* SUSPECT FAULTY PRE COOLER. REPLACED PRE COOLER LEAK CHECKED GOOD. AC OK FOR SERVICE.
Part: SHUTOFF VALVE — MALFUNCTIONED (FUEL SYSTEM) · airframe 49,139 hrs · 7,315 cycles
ENG FUEL VALVE L LEFT HIGH PRESSURE (HP) FUEL SHUTOFF VALVE POSITION DISAGREES WITH COMMANDED POSITION.
Part: CONNECTOR — DIRTY (FMU) · airframe 49,139 hrs · 7,315 cycles
ENG FUEL VALVE L LEFT HIGH PRESSURE (HP) FUEL SHUTOFF VALVE POSITION DISAGREES WITH COMMANDED POSITION. ACP'D FMU ELECT WIRES AND CONNECTORS SECURITY, CLEANED CONNECTORS AT FUEL METERING UNIT AND ENG START CHK OK. A/C OKAY FOR SERVICE.
Part: LUG — CORRODED (NR 2 GENERATOR) · airframe 48,217 hrs · 7,204 cycles
FOUND NR 2 ENGINE GENERATOR FEEDER LUGS DISCOLORED, PITTED AND PROTECTIVE COATING FLAKED OFF. SUSPECT PITTING AND CORROSION. REPLACED TERMINAL LUGS PER SWPM 20-15-21. PAGE 5.ACCOMPLISHED ENGINE RUN AND OPS GOOD PER MM-24-11-19 P410. ACFT OK FOR SERVICE.
2007
Part: UNKNOWN — ODOR (CABIN) · airframe 47,935 hrs · 7,170 cycles
ROWS 11-13 RIGHT AISLE AREA HAD BURNING ODOR. CLEARED UP AFTER 5 MINUTES. PERFORMED ALL CABIN'S LIGHT AND BALLAST OPN AND EVIDENCE OF SMOKE AND BURNING ODOR-FOUND NONE, CHECKED DOOR 2 GALLEY'S ALL EQUIPMENT OPERATION-ALL GALLEY 'S EQUIPMENT OPERATION NORMAL. NO BURNING ODOR CONDITION NOTED WITH BOTH PACK'S ON AND ALL CABIN EQUIPMENT SYSTEM TURNED ON. UNABLE TO DUPLICATE PROBLEM.
Part: PROCESSOR — MALFUNCTIONED (FUEL QTY IND) · airframe 47,935 hrs · 7,170 cycles
FUEL QUANTITY INDICATION ON EICAS DISPLAY FLUCTUATES. CREW COMMENTS: RIGHT FUEL QUANTITY INTERMITTENT. FUEL QUANTITY PROCESSOR UNIT FAULTY. REPLACED FUEL QTY PROCESSOR UNIT. PERFORMED OPERATIONAL CHECK OK. ACFT OK FOR SERVICE.
Part: ANTENNA — FAULTY (VHF SYSTEM) · airframe 47,911 hrs · 7,166 cycles
VHF RADIO - RECEPTION PROBLEM CREW COMMENTS: GARBLED RECEPTION ON VHF 1. ALL POSITIONS - ALL FREQ. NOT A HEADSET PROBLEM. FOUND CONNECTION AT LT VHF ANTENNA. REPLACED VHF ANTENNA. ACFT OK FOR SERVICE.
Part: FMU — LEAKING (FUEL SYSTEM) · airframe 46,870 hrs · 7,036 cycles
FUEL LEAKING BETWEEN FUEL PUMP AND FMU. REPLACED NR 2 ENG FMU UNIT. LEAK CHECKED OK. CAUSE WAS CONNECTION SECURITY OR FAULTY SEAL. VERIFICATION FLIGHT CONFIRMS NORMAL OPERATION.
Part: FLOAT VALVE — STUCK (CTR FUEL TANK) · airframe 46,426 hrs · 6,982 cycles
FUEL IMBALANCE EXIST WHEN CTR TANK FUEL IS PRESENT. RT MAIN RECEIVING EARLY TRANSFER FROM SCAVENGE PUMPS. SUSPECT CTR TANK SCAVENGE FLOAT VLV STUCK IN OPEN POSITION AFTER T/S WITH FLT CREW.
Part: UNKNOWN — UNKNOWN (FUEL TRANSFER SY) · airframe 45,808 hrs · 6,899 cycles
UNEVEN FUEL TANKS AND CTR SCAVENGE SYS CTR TANK APPEARS TO BE TRANSFERING TO RT MAIN IMMEDIATELY. LT MAIN QTY UNCHANGED AND RT INCREASES ABOUT 2.3 DURING 1ST 2 HRS. IT ONLY TRANSFERED WHEN CENTER PUMPS WERE ON AND APPEARED TO FILL RT TANK TO LIMIT. OPTED RIGHT FUEL SCAVENGE SYSTEM. REVIEWED PREVIOUS HISTORY OF EARLY FUEL TRANSFER INTO RT MAIN FROM CENTER FUEL TANK. MX PERFORMED FUEL TRANSFER CHECK AND WAS NOT SUCCESSFUL IN DUPLICATING EARLY TRANSFER FROM THE CENTER RT FUEL SCAVANGE PUMP. THIS ITEM IS TO REMAIN OPEN FOR 3 FLT CYCLES FOR CREW COMMENTS ON REOCCURRING PROBLEM. NO PROBLEMS IN LAST SIX LEGS AS OF 24JUL2007. AIRCRAFT RETURNED TO SERVICEABLE STATUS.
Part: BALLAST — OVERHEATED (CABIN LIGHTS) · airframe 45,788 hrs · 6,897 cycles
LAV 100 MIRROR LIGHT ASSY SHOWED SIGNS OF OVERHEATING. [08-07-07] REPLACED LIGHT ASSY AND BALLAST. OP CK GOOD.
Part: LINE — LEAKING (FUEL SYSTEM) · airframe 45,767 hrs · 6,894 cycles
NR 2 ENGINE HAS FIRE DAMAGE FROM FUEL LEAKING AT THE MAIN FUEL SUPPLY HOSE AT THE NACELLE DISCONNECT PANEL. FIRE NOT CONFIRMED. ECM DATA SHOWED UNDER COWL TEMPERATURES TO BE NORMAL. HOWEVER, THERE WAS DAMAGE DUE TO A FUEL LEAK IN THE AREA. DAMAGE WAS FOUND DURING A ROUTINE C-CHECK. WHAT WAS DESCRIBED AS "SCORCHING" WAS FOUND IN THE AREA UNDER THE HOSE PANEL. THE FUEL SUPPLY LINE (BOEING IPC REF. 73-11-08-01-050) WAS LEAKING FROM THE UPPER CONNECTION AT THE NACELLE DISCONNECT PANEL. NO PLASTIC MATERIALS (HOSES, CLAMPS, HARNESSES) APPEARED TO HAVE MELTED. THE FUEL SUPPLY LINE WAS REPLACED. ENGINE TIME SINCE INSTALLATION 14457 HOURS (2085 CYCLES).
Part: BUTTON — MISSING (R4 DOOR) · airframe 45,600 hrs · 6,870 cycles
DOOR 4 RIGHT IS MISSING EPIS BUTTON. [07-20-07] NEW TYPE OF EPAS BATTERY PACK INSTALLED PER AMM 52-11-20 CONFIG 2 PG401 & TEST OK PER AMM. PUSH BUTTON SECURED. OK FOR SERVICE.
Part: MODULE — MALFUNCTIONED (HYD INTERFACE) · airframe 45,140 hrs · 6,810 cycles
RIGHT HYDRAULIC SYSTEM INOP. QTY SHOWS ZERO. [SUP 06-06-07] REPLACED HYDRAULIC INTERFACE MODULE (HYDIM) (R) CARD. ACTIVE DC HARD FAULT. AFTER REPLACEMENT, INDICATIONS RETURNED TO NORMAL.
Part: DOOR — OBSTRUCTED (L4) · airframe 44,464 hrs · 6,712 cycles
FLT ATTENDANT REPORTED UNABLE TO ARM DOOR 4L. *S/D* REMOVED FOREIGN OBJECT OPERATES NORMAL. AIRCRAFT RETURNED TO SERVICE. SUSPECT FOREIGN OBJECT WAS PIECE OF CABIN SERVICE MATERIAL.
Part: LINE — LEAKING (LT IDG) · airframe 44,053 hrs · 6,654 cycles
FLIGHT DIVERTED DUE TO LEFT GENERATOR PROBLEM. FOUND INTEGRATED DRIVE GENERATOR (L) OIL LEVEL IS LOW. FOUND IDG OIL SERVICE LINE LEAKING. REPLACED LINE. RAN ENGINE AFTER IDG SVCE LINE INSTALLED. IDG OPS NORMALLY. A/C RETURNED TO SERVICE.
Part: GIRT BAR — FROZEN (R4 DOOR) · airframe 44,032 hrs · 6,651 cycles
UPON ARRIVAL FLT ATTENDANT UNABLE TO DISARM DOOR 4R. FOUND GIRT STILL FROZEN TO SILL. WARMED & DRIED OFF AREA, CLEANED AND GREASED GIRT BAR MECHANISM AND ARMING MECHANISM. DOOR 0PERATES NORMALLY. REACTIVATED BOTTLE AND SLIDE. CYCLED ARM-DISARM LEVER, OPENED DOOR SEVERAL TIMES. CLEANED GIRT BAR AREA OF MOISTURE PER MT 52-UA4R3. DOOR OPERATES NORMALLY. RETURN TO SERVICE.
Part: LIGHT — MISSING (CABIN) · airframe 43,872 hrs · 6,628 cycles
AFT EEL LIGHT MISSING AT SEAT 1E. REPLACED THE MISSING LIGHT ASSY. OPS CHECKED OK.
2006
Part: O-RING — UNSERVICEABLE (SLIDE BOTTLE) · airframe 43,264 hrs · 6,548 cycles
LOW BOTTLE PRESSURE. SLIDE REPLACED. A/C RETURNED TO SERVICE. BOTTLE LEAKING AROUND THE SHAFT. REPLACED WITH NEW SHAFT, BACK O-RING AND SHAFT O-RING. SUSPECT O-RING CRUSHED BY SIDE LOAD WHILE IN SERVICE.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 39,961 hrs · 6,062 cycles
EMERGENCY LIGHT INOP OR MISSING AT SEATS 8F FWD, 3F AFT.
2004
Part: WARNING LIGHT — ILLUMINATED (BLEED SYSTEM) · airframe 33,548 hrs · 5,141 cycles
BLEED LOSS WING LEFT AND BLEED LOSS BODY LEFT EICAS MSGS. ALSO HYD PRESS DEMAND CI MSG. FOUND THE LOWER FLOW CONTROL VALVE INSTALLATION CLAMP BROKEN WITH APPRECIABLE BLEED AIR LEAKAGE. FURTHER INVESTIGATION OF THE CLAMP FOUND FAILURE OCCURED AT A SPOT WELD ADJACENT TO THE LOOP THAT SECURES THE TIGHTENING TEE BOLT TO THE CLAMP ASSEMBLY. AS A RESULT, THE CLAMP LOST ALL TENSION. THE CLAMP WAS REPLACED AND LEAK CHECK ACCOMPLISHED.
Part: SKIN — DAMAGED (FUSELAGE) · airframe 32,689 hrs · 5,013 cycles
FUSELAGE DAMAGE LOCATED 4 INCHES BELOW STRINGER 29L AT STA 655, GOUGE IS 7 INCHES LONG WITH MAX DEPTH .020 INCH. MAJOR REPAIR. DOUBLER IS INSTALLED AT STA 632-642, STR 28L ON LT FUSELAGE EXT SKIN. DOUBLER IS 22 INCHES BY 14 INCHES.
Part: BLADE — CRACKED (NR 2 ENGINE) · airframe 31,309 hrs · 4,809 cycles
NR 2 ENGINE COMPRESSOR STALLED IN CRUISE. POWER REDUCED TO IDLE. THE 6TH STAGE HPC INNER SHROUD ASSEMBLIES (PW IPC 72-35-00-17-001/-010) WERE FOUND TO HAVE BEEN INSTALLED BACKWARDS. THIS ALLOWED THE SEAL LAND TO MAKE INTERMITTENT CONTACT WITH THE TRAILING EDGE OF ALL OF THE 6TH STAGE BLADES NEAR THE AIRFOIL ROOT. A CRACK STARTED IN THE TRAILING EDGE OF ONE OF THESE BLADES, AND PROGRESSED IN FATIGUE TO THE AIRFOIL MID-CHORD. AT THAT POINT, THE REMAINDER OF THE BLADE FAILED IN STRESS RUPTURE. ALL 6TH STAGE BLADES, AND ALL OTHER HPC BLADES DOWNSTREAM OF THE 6TH STAGE, SUFFERED HEAVY RESULTANT DAMAGE.
2003
Part: CONTROL VALVE — FAILED (RT PACK FLOW) · airframe 29,601 hrs · 4,535 cycles
RT AIR CONDITIONING PACK FLOW CONTROL VALVE STATUS MESSAGE. RT LOWER FLOW CONTROL VALVE FAILED DUE TO BAD PROXIMITY SWITCH. RT LOWER FLOW CONTROL VALVE REPLACED.
2002
Part: BRACKET — BENT (NR 2 NACELLE) · airframe 24,985 hrs · 3,820 cycles
NR 2 ENGINE CROSS TIE INBOARD LEG UPPER BRACKET IS BENT AND FASTENER CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED UPPER BRACKET FOR CROSS TIE.
2001
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 21,863 hrs · 3,330 cycles
THE BODY STATION 246 FLOORBEAM MID CHORD IS CRACKED AT LBL7.88, RBL26.06 AND RBL 38.00. MAJOR REPAIR ACCOMPLISHED. A NEW ANGLE SECTION WAS SPLICED PER SRM 53-10-51-201 REPAIR 2.
Part: WARNING SYSTEM — MALFUNCTIONED (COCKPIT) · airframe 20,096 hrs · 3,043 cycles
LOW OIL PRESSURE WARNING INTERMITTENTLY COMING INTO VIEW WITH OIL PRESSURE SHOWING 211 PSI (NORMAL), ALSO WHEN OIL PRESSURE WARNING OCCURRED N1, EPR AND FF FLUCTUATING OCCURRED. AT FL390 M.84V 4 HRS AIRBORNE EICAS MSG ENG OIL PRESS L CAUTION APPEARED OIL PRESSURE READ NORMAL AT 210 PSI (CONT'D).
Part: TUBE — LEAKING (ESCAPE SLIDE) · airframe 17,520 hrs · 2,641 cycles
DURING SHOP OVERHAUL, SLIDE RAFT FAILED INFLATABLE AIR RETENTION TEST OF THE TOP TUBE.
1998
Part: OUT FLOW VALVE — FAILED (CABIN)
AT FL350 FLIGHT CREW GOT EICAS MESSAGE: 'FWD OUTFLOW VALVE'. AIRCRAFT DESCENDED DUE CLIMBING CABIN. CREW COULD NOT CONTROL CABIN PRESSURE. CAPTAIN DECLARED AN EMERGENCY AT FL240. FLIGHT CLEARED TO 10,000 FEET. DURING DESCENT, ALL OXYGEN MASKS DEPLOYED.