N78KN

GULFSTREAM AEROSPACE CORP GVII-G500 · 2021 · Valid Registration

Registered owner: H4T CORP, NH (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
SUNSET AVIATION LLC (7SSA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

K · 2012-01-11 Matched by certificate designator
ATA 7830

LT ENGINE, INBD THRUST REVERSER ACTUATOR LEAKING. MM SPECIFICALLY STATES THERE ARE NO ALLOWABLE LEAKAGE FOR COMPONENTS, FILTERS, PRESSURE SWITCHES, TRANSDUCERS, VALVES OR TUBING UNLESS SPECIFICALLY MENTIONED AND TO CONTACT MFG CUSTOMER SUPPORT WHEN ANY MX ON THE THRUST REVERSER SYSTEM IS PERFORMED, INCLUDING PART REPLACEMENT, ADJUSTMENT OR REPAIR. OUR TECH REP AS CONTACTED AND WE REMOVED THE ACTUATOR AND INSTALLED A NEW UNIT IAW AMM 78-30-03. OPS AND LEAK CHECKED GOOD.

Source: SDR ZKFR201201113243 · FAA SDRS
K · 2012-01-11 Matched by certificate designator
ATA 7830

RT ENGINE, INBD THRUST REVERSER ACTUATOR LEAKING. MM SPECIFICALLY STATES THERE ARE NO ALLOWABLE LEAKAGE FOR COMPONENTS, FILTERS, PRESSURE SWITCHES, TRANSDUCERS, VALVES OR TUBING UNLESS SPECIFICALLY MENTIONED AND TO CONTACT MFG CUSTOMER SUPPORT WHEN ANY MX ON THE THRUST REVERSER SYS IS PERFORMED, INCLUDING PART REPLACEMENT, ADJUSTMENT OR REPAIR. OUR TECH REP AS CONTACTED AND WE REMOVED THE ACTUATOR AND INSTALLED A NEW UNIT IAW AMM 78-30-03. OPS AND LEAK CHECKED GOOD.

Source: SDR ZKFR2012011103243 · FAA SDRS
O · 2011-12-22 Matched by certificate designator
ATA 3810

POTABLE WATER IN LAV HAS LOW PRESSURE AND PUMP CONTINUOUSLY CYCLES. R & R DRAIN CHECK VALVE. OPS CHECKED GOOD. INSPECTED CHECK VALVE ON BENCH AND FOUND VALVE NOT COMPLETELY CLOSING AND REQUIRING EXCESSIVE PRESSURE TO CLOSE AT ALL.

Source: SDR ZKFR201112223218A · FAA SDRS
O · 2011-12-22 Matched by certificate designator
ATA 3397

AFT BAY MX LIGHT WILL NOT STAY ON. FOUND MULTIPLE BROKEN WIRES AT AFT STEP FAIRING, SWITCH TO SPLICE, ON LT AND RT SIDE OF ACCESS DOOR. REPAIRED AFFECTED WIRES. OPS CHECKED GOOD.

Source: SDR ZKFR201112223218B · FAA SDRS
J · 2011-12-22 Matched by certificate designator
ATA 3140

WITH ONLY APU RUNNING, MAU 2B FAULTED RESULTING IN THE APU SHUTING DOWN. PILOT RESTARTED APU AND FAULT DID NOT RETURN. MX COULD NOT DUPLICATE PROBLEM. FAULT HISTORY DOWNLOADED, CHANGE THE MAU 2 NIC 2 MODULE ASSY WITH PROCESSOR. OPS CHECKED GOOD.

Source: SDR ZKFR201112223218C · FAA SDRS
O · 2011-11-15 Matched by certificate designator
ATA 2197

WHILE CHANGING LT AFT BAY HEAT EXCHANGER FOUND CB PANEL 3, PLUG P1634D, PIN: M FOR WIRE A201-W01-16 CAPPED AND TIED BACK CAUSING LT AFT BAY BLOWER TO BE INOPERATIVE. MECHANIC BELIEVES THIS TO BE DONE DURING ACFT PRODUCTION OR AT BLOCK 20 UPGRADE. MECHANIC RECOMMENDS OTHER OPERATORS CHECK FOR OPERATION AS THERE IS NO COCKPIT INDICATION WHEN THESE FANS ARE INOP AND THEY ARE FOR HEAT PROTECTION FOR THE COMPOSITE REAR PRESSURE BULKHEAD STRUCTURE. SEE CONTROL ZKFR113188A FOR OTHER SN.

Source: SDR ZKFR201111153188 · FAA SDRS
O · 2011-11-15 Matched by certificate designator
ATA 2121

DURING POSTFLIGHT, FOUND BOTH AFT BAY HEAT EXCHANGER FANS INOP. R & R BOTH HEAT EXCHANGERS FANS. OPS CHECKS GOOD. MX RECOMMENDS OTHER OPERATORS CHECK FOR OPS AS THERE IS NO COCKPIT INDICATION WHEN THESE FANS FAIL AND THEY ARE FOR HEAT PROTECTION FOR THE COMPOSITE REAR PRESSURE BULKHEAD STRUCTURE.

Source: SDR ZKFR113188A · FAA SDRS
O · 2011-11-15 Matched by certificate designator
ATA 2150

LT PACK FAILED IN FLIGHT WHEN THROTTLES PULLED TO IDLE. R & R LT PACK PRESSURE RELIEF SHUTOFF VALVE (PRSOV). SYS OPS CHECKS GOOD.

Source: SDR ZKFR201111153188D · FAA SDRS
O · 2011-11-15 Matched by certificate designator
ATA 2121

DURING POSTFLIGHT FOUND BOTH AFT BAY HEAT EXCHANGER FANS INOPERATIVE. R & R BOTH HEAT EXCHANGERS FANS. OPS CHECKED GOOD.

Source: SDR ZKFR201111153188B · FAA SDRS
O · 2011-10-16 Matched by certificate designator
ATA 3160

DURING POST FLIGHT, FOUND CMC INOPERATIVE ON CO-PILOTS MFDU. FOUND FILE SERVER 2 AFSEM 2 FAULTED. PERFORMED TARGET LOAD OF SOFTWARE LOAD 20 AND SYS CHECKED GOOD.

Source: SDR ZKFR2011131600003 · FAA SDRS
L · 2011-10-16 Matched by certificate designator
ATA 3070

GALLEY DRAIN INOPERATIVE AT SINK AND COFFEE MAKER. FOUND HEATED DRAIN LINE IS NOT HEATING UP.

Source: SDR ZKFR2011131600002 · FAA SDRS
O · 2011-09-28 Matched by certificate designator
ATA 4500

FOUND CMC CARD TO BE FAILED. R & R CMC MODULE ASSY (CARD). OPS CHECKS GOOD.

Source: SDR ZKFR201109286209 · FAA SDRS
O · 2011-09-23 Matched by certificate designator
ATA 2923

ERS PUMP LEAKING. FOUND LEAKING FROM OVERBOARD DRAIN LINE. R & R ERS PUMP ASSY.

Source: SDR ZKFR201109233149 · FAA SDRS
O · 2010-04-23 Matched by certificate designator
ATA 2913

DPI FOUND EXTENDED DURING PF INSPECTION. REMOVED FILTER AND FOUND MINOR METAL IN FILTER AND FILTER HOUSING. REPLACE RT HYDRAULIC ENGINE DRIVEN PUMP.

Source: SDR 2010F00110 · FAA SDRS
O · 2009-11-19 Matched by certificate designator
ATA 2913

DPI FOUND EXTENDED DURING INITIAL 100 HOUR INSPECTION. REMOVED FILTER AND FOUND METAL IN FILTER AND FILTER HOUSING. REPLACE RT HYDRAULIC ENGINE DRIVEN PUMP.

Source: SDR 2010F00109 · FAA SDRS